Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 �FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT SCANNED SCAI�NNED Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERC€, FL , Owner: �An X t�.v C\ � Permit Number: Jurisdiction: B y St, Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft� 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.63 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. --- - - Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.93 PASS Total Baseline Loads: 53.85 1 hereby certify that the plans and specifications covered by Review of the plans and Fg1iE Sr this calculation are in pliance with the Florida Energy specifications covered by this y� _;_ 80A Code. calculation indicates compliance w` °„ �O� with the Florida Energy Code. r+ runK" , ••`.•: °:• PREPA D Before construction is completed e. DATE: this building will be inspected for compliance with Section 553.908 0 y . u a I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. COD S¢v with OWNER!p T. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC fit 0 63 ft' — 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH Bit 0 56 ft' — 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' -- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY t ft 0 36 ft' -- 0 1 0 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft' 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' __ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 It 0 209 ft' _- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' _- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft' _- 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 It 0 92 ft2 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft' — 0 1 0 ROOF J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft' 292 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft' 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft' 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext In9dASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 —2 SW=>E Exterior Concrete Block - Ext IndMASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext Infi EDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext IndWNING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext IndXNING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext Insul(ITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext In9iEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext IndilEDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft' 1 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 It 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 It 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft' 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.66 0.21 N 40.0 ft' 8 ft 0 in 1 It 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2678 7 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kStu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split SEER: 15 34.8 kBtu/hr cfrn 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre Thermostar[t:'Y Cffeilling Fans: Heat ng [ Jan Feb r[x]j' Mar [[ ]] Jun [x] Jul [[ [XJ Aug [[ [Xl Sep [[[ r()C,) NovfDC,I Dec Venting I Jan I I Feb I l IX) Mar LxJ Apr [ ]May lXJ Jun [[ 11 Jul [I Aug [I Sep .j]] lxl l�l Oct [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default 8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 3 Name: Test Rater Signature: Rating Compant: Test Rater Date: 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. Jurisdiction: w _ Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a'sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dropped ceiling/soffit y ai 9 the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned Spec Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nqp1no and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover nlates and walls or ceilings a. In addition, Inspection Of log walls shall be in accordance with the provisions of IGG-400. 11/19/2018 2:40 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/Water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.635 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.239 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec°/a B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE WINDSOR k Al O City/FL Zip: FT. PIERCE. FL '�-t 4 'A , 11/19/2018 2:39:50 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft• Project SummaryJob: Entire Da re House te' QUICK CALCS, INC. For. WYNNE DEVELOPMENT THE WINDSOR, Fr. PIERCE, FL SCANNED Notes: St. BY County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design T.D15 OF Daily range L . Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average Area (ft) He 1753 Co 17� Volume2(fta) 14741 14741 Airchanges/hour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A•030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47•F 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate(swing multiplier 0.95 Equipmenf sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carder Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil . FX4DN(B,F)037 AHRI ref 79145M Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling. 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsotr RightSuile® universal 201717.0.14 RSU08101 2017-Apr-1017:1928 '�` ...k CaIcslDocumentslwYNNE-THE WINDSOR-REVISED.mp Calc = MJS Front Door faces: N Page 1 ' 41- wrightsoft• Right -A Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4688799 Fax 7724666796 Email: OUICKCALCS@,AOLCOM 1 Room name Entire House MASTER BEDROOM Rcowed wall 153.0 ft 45.0 ft 3 m height 9 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft' 280.0 ft- Ty Construction ll-value Or HTM A ea Load Am number (BtuWfR°F) (BWWftj or perimeter (ft) (Rh) or perimeter (ft) (Btuh) Heat I Cool Gnus WP/S Heat Cool Gross I WP/S Heat Cool 6 13AAocs 0.143 no 400 2.55 488 448 1795 1141 192 192 769 489 1Acl m: 1270 no • 3556 -70.43 7 • . 0 , ;247 : 488 0'- 0 0 '-0 1:270 ne; 1 3556 .: 70.43 18 -: 0 , .:.581 : --. .1151 0 `- - 0._ 0 1- 0 1A'ctom 1:270 ne-. '-'35.58 - '45.24 16, 0 - -581 -: 739 . -0.' 0 -. .0 . 7,+6 11 y/ 13AAccs 0.143 se 4.00 2.65 64 41 165 105 0 0 0 - 0 r-D ,11D0 0.390 se 1092 11.31 23 23 248 257 0 0 0 0 13A-0cas , , O.M sw -. �400 .. Z55 - -437' . 396- '1684 •' . ; 1007 ' :56 - 56 220, 4A5-2om..- 0.770 .sw ` 216s -:'� Mi 41 " 45 .'-893 1140 o 0 ". 0 y/ 13A4ocs 0.143 nw 400 2.55 290 217 867 551 112 79 318 _ -1 202 1A-clom 1.270 w 3556 45.24 33 0 1162 1478 33 0 1162 1478 11----fC'' 4AS2omd. 0.770 my 21.56 35.90 41 0 880 1505 0 0 0 0 P .=.,.12C11sW-.. 0.091-' ,.2.55 `- 128� -308l-' 308' "-784� 395" '0. -.p... 0" C 16A-30mtl 0.032 - 0.90 232 1763 1763 1571 4067 280 280 261 650 F ' '22A-tpl : - G.989 :.._. - 27.69 " 0.00 - 1753 ..: ..153 4237 : -70 • 280 -45 - 1246 :.. `: " -0 6 c)AM e>aursion 1360 600 Envelope loss/gain 15594 16385 1 3970 3561 12 a) Infiltration 2873 810 809 228 b) Rcomventilation 0 0 '0 0 13 Internal gains: Occupants Q 230 2 460 0 0 Appliances/other 1000 0 Subtotal Qirres 6 to 13) 18467 17655 4779 3789 Less ardemai load 0 0 0 0 Loss Dana er 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18. 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air regtired(cfm) 1160 1160 30D 249 A& wrightSaft- Right-Sulte® Universal 2017 17.0.14 RSU08101 ...k Ca1cs\Documen1s\WYM4E-THE WINDSOR-REVISED.rup Cole =MJ8 Front Door faces: N 2017-Apr-10 17.19:28 Page 1 wrightsoft• Right.J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. sy: 317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email OUICKCALCS @AOL.COM 1 Room name WIC M. BATH wall O ft 7.0 ft 3 Room height 9ht 8.0 ft heat/cool 8.0 It heaUcool 4 Room dimensions 7.0 x 9.0 It 1.0 x 61.0 It 5 Room area 63.0 ft' 61.0 ft' Ty Const"UW U-value Or HTM Area Load Am nuns (Etutyftle F) (Bft"ft') or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cod Gross WP/S Heat Coal 6 W. 13A4ocs 0.143 no 400 255 .0 0 0 0 66 49 196 125 ;IA Glom - .1.270 ` ne - 35.56 .70.43 - - 0 0 - . 0 .0 7 " 0 247 488 r 7Ao1om '.. •. -.'' 1.270 no .35 56 : 70.43 . .0 . -. - M : ,.0 0 0 � -. 0 > 0 =+:0 i1Aclom 1.270'ne ,. '`35.56 45.24, 0. '0 0 0" 0. .p .':,:0 11 VjI �D 13A4ocs 0.143 se 4.00 Z55 0 0 ..0- 0 0 0 0 0 0 11DO se, 1092 11.31 0 0 0 0 0 0 0 0 �Yy13A-0ocs ^L==C•'4AS2om ;' .0.390 �0.143 sw '�400 _.. 2:55 0 . 0' . 0 =.0 ';. ., 0. 0 . q<:p :: 0.770 .sw 21.56. "2Z53 ':0 _, . 0 -- 0 0 .. 0 .. •0.: •.0 _ .'=�0 4)! 13A-0ocs 0.143 rive 4.00 255 0 0 0 0 0 0 0 0 lL---GG 1Aa1om 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2ornd, 0.770 nw 2.1.56 36.90 0 0 0 0 0 0 0 0 P... "i .12C-0sw 0.091 :.: • :, -2.55 i 128 �0 �0 ,. .. 0 - 0 .. . 0' O "r p -. ; ':0 C 16A-tpl 0.032 - 0.90 232 63 63 56 146 61 61 55 142 'F" ` 22A-tpl " 0.989 -- . 27.69 'C -' 0.00 . 63 0 - .0 0' 61 ',7 - 194 ... - 0 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 6S2 729 12 a) Infiltration 0 0 126 35 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 141 817 764 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 56 141 817 764 15 1 Duct loads 34% 63% 19 75 340/. 530/6 274 4D4 Total roam load 75 216 1091 1168 Airrequired(clm) 4 9 51 50 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrilghtsoft• 2017-Apr-1017:19:28 p THEWINDS Universal201717.0.14 RSU08101 Page2 ...k CaleslDocumentslWYNNE•THE WINOSOR-REVISED.rup CaIc=MJB Front Doorfaces: N wrightsoft- Right-JO Worksheet Job: Entire House pate: QUICK CALCS, INC. By: 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fa c 772466-6798 Email: QUICKCALCS@AOL.COM 1 Roomname LAUDRY BEDROOM Ex�ooswall 0 ft 120 It 3 height 8.0 ft heaticool &0 ft heat/cool 4 Room dimensions 6.0 x 6.0 It 15.0 x 12.0 It 6 Room area 36.0 W 180.0 ft- Ty Ccnstrnctim U-%olue Or HTM Area l� b l� number (Btuh/ftMF) (BtuwfN) or perimeter r (ft) (Stuh) orperimeter (ft) (Btuh) Heat Cool Gmss WP/S Heat Cool Gross WP/S Heat Cool 6 1344ocs - 0143 ne 400 255 0 0 0 0 96 80. 319 1Aclom'".' .1270 ne 43556 70.43 -. 0 0 0 0` " 0.: ,- 0 _.203 - - 0 1Ac1om -;, -- 4270 :,no °'3556-, .;70.43= 0 0' - 0 ..0 `-0 .16 0, 581 .1151 AA-clom - .1.270 ne - 35.56 _45.24 - 0 ; 0 - - 0. ' �0 - 0. 0 - 0 -- 11 y/ 13A-0acs 0n43 se a.00 2S5 0 0 0 0 0 - 0 0 0 `D 11D0 -13A-0acs -... 0390 se 10.92 t1.31 0 0 0 0 0 0 0 Vy �4AS-2cm 0143 sw' .',4.00 .... 2.65 0` o- 0 .-0 - 0," .0 :0--, p - •, .•D L1-G' _. 0.770 sw::. ..:21.56 `27.53 ' .0 0 - - o 0 . - _ 0 : 0 "o Vjl 13AAocs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 tAatom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 t��fa ., ,....12C-Wv 4A5-2omd -, 0.770 rw 21.56 36.90 0 0 0 0 0 0 0 0 P ... 0.091 .._. 2.55 1.28 .. .0. -.0 - 0,, .. U _.-o ._ ,<0- ....0, _ 0 C 16A30md 0.032 - .0.90 232 36 36 32 84 180 180 161 _ 418 F ":.•. 22A-tpl :_ - 0.989: - - 27.69 : 0.00 36 0. 0 ' 0 :. 180 12 :'- ..:332 .'.: .: 0 6 c)AEE excursion S SO Envelope lcss/gain 132 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 32 81 1609 1772 Less external load 0 0 0 0 Less transfer 0 p p p Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 50 W/. 53% 541 141 Total room load 1 2101 271 Atr required (cfm) 2 6 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed • wrightsoft- 2017-Apr-1017:19:28 A RightSuiteO Unlwrsal 2017 17.0.14 RSU08101 Page 3 ...k Calcs\DocumenlslVNWE-THEWINDSOR-REVISED.mp CBIc=MJB Front Doorfaces: N + wrightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 772-46M799 Fax 772.466-6796 Email: QUICKCALCS@AOL.COM 1 Roam name DINING/GREAT ROOM KITCHEN 2 Fposed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heaVcool 8.9 ft heaVcool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 5W.0 W 209.0 ft' Ty Construction U-value Or HTM Area (ft.) Load Area Load number (Btuh/ftk F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (I3tuh) Heat Cool Gross N/PIS Heat Cool Gross WP/S Heat Cool 6 13A,4ws 0143 ne 400 255 0 0 0 0 0 0 0 -0 1Acl m +. 1270 ne 3558 70.43 0 .0 0 0 0: 0" 0 - l0 .!wbibm 1Ac1om-S - _ 1.270 ne '> '3556 :. 70:43 0 01 0 - 0 0 ' 0 •. 0 _ 0 _,. r1.270 ne -:'35.56 4524 0- 0 0-• 0 -0 - 0 10 .. •0 11 Y--D 13A-0acs 0.143 so 4.00 255 0 0 0 0 0 0 0 0 11DO 0390 se 1092 11.31 0 0 0 0 0 0 0 0 W 13A-0obs4::.: �445 .0143 sw -. 400 ... 255: 267, ..226'-•",9D3.-" -. 574 -'98 ;. ;98. 392 +-.249 1—G tom 0 770 : sw ' ; 21.56 • -� 27:53 41 - 22 893 1140 ' . - 0 0 .0 .: 0 L1r 13A4acs 0.143 nw 4.00 255 178 137 549 349 0 0 0 0 l—G 1Aciom 1.270 my 35.56 4524 0 0 0 0 0 0 0 0 �G 4A5-2amd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P.' "'. `;12C-0sim`' _0.091 "Z55" .1i28 0 _ 0 0 0 - '116 - 116 ';, 295" -'148 C -.' 16A-30md 0.032 - 0.90 232 588 688 527 1364 209 209 187 485 IF 22Akpl .. .. 0.989 -. 27.69 ;: •.0.00 - - S88 - '50 1335 .0 • 209 ..11 3D5 ,. :. '0 6 c)AED mmursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 10D0 282 220 62 b) Room ventilation 0 0 0 0 13 Ntemal gains: Occupants @ 230 2 460 0 0 Applianoes/other 0 1000 Subtotal Qines 6 to 13) 6136 6679 1399 1880 Less exemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 995 Total roam load 8200 10234 1 1867 2875 Air required (cfm)' 3% w 88 124 � A ' - wrightsoft- RightSufte® Universal 201717.0.14 RSU08101 ... k Calcs Documsnts%WYMJE-THE WINDSOR-REVISED.mp CaIc=MJ8 Front Doorkces: 2017-Apr-10 17:19:28 Page 4 wrightsoft• Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall. Room height Room dimensions Room area BATH 80 ft 5.0 ft heaUccol 10.0 x 5.0 It 60.0 W HALL 8.0 It 0 ft heat/cool 5.0 x 6.0 ft 25.0 W Ty Cons6uction number U-value (Btutnftz. Or HTM (BtuNft2) Area or perimeter (ft) Load (Btuh) kea (ftl or perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 11 13440cs - Wcl= wdiom 1Aciom .. -' 13A-0ocs 11DO 13AAocs=: .4A5-tarn . _ 13A-0ocs 1A,c1om 4A5-2omd 12C-0sw- .. 16A30md : 0.143 - 1:270 '1i270 1:270 0.143 0.390 ,: 0.143 •0.770 0.143 1.270 0.770 0.091 0.032 ..0.989 no ne ne no-,35.56 se se sw sw nw nw my - - - 400 '.3556 3556 4.00 1092 .",'400 e. M.56, 4.00 35.56 21.56 255- 0.90 27.69 2.55 70i43 r 70.43 - A5.24 255 11.31 .>;255 -27.63 255 45.24 36.90 1.28 2.32 ..._0.00 40 0.' 0'<� 0.... 0 0 0 0'< ' 0 0 0 0. 60 50 40 0. 0 0', 0 0 •... 0.' 0 0 0 0 .0 50 5 160 0 0 0 0 0 0 0; 0 0 0 0. 45 :138C , 102 .0 `0 .,. 0 0 0 ..: ..0 0 0 0 0 0' 116 0 0 0 0 `0 0 0 .. 0 - 0' 0 0 0 "0 25 ,. 25- 0 0 r 0 ° o' 0 0 i. .0 .0.= 0 0 0 0 26 0'. 0 •' 0 < 0 0 0 0 .. 0 .. 0 0 0 0 011 22 .0:. 0 <p -"'0 . "0 0 0 ,.'.p0 ,0 0 0 0 .0 58 '.,%;o W �D L'IN-G r--G C F`..-.22A-tp[ 6 c)AED excursion -g -2 Envelope loss/gain 343 210 22 66 12 a) infiltration b) Room ventilation 90 0 25 0 0 0 0 0 13 Internal gains: Occupants @ 230 Applianceslother 0 0 0 0 0 0 Subtotal Qlnes 6 to 13) 433 235 22 66 14 15 Less ademal load Less transfer Redistribution Subtotal Duct loads 34°/a 53% 0 0 6 439 147 0 0 14 249 132 340/6 53% 0 0 - 0 0 0 0 0 S6 0 0 Total room load Air required(c/m) 586 28 381 16 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed _41-wrightsoft- Right-Suite(E)Universal 201717.0.14 RSU08101 2017-APr-1017:19:28 ...k CalcslDocuments\WYWE-THE WINDSOR-REVISED.rup Cale =MJ8 Front Door faces: N Page wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALC$ INC. By: 317 ST. LUCIE LN.. FT. PIERCE, FL 34946 Phone: 772A66-6799 Fa 772A6"796 Email: 1 Room name FOYER BEDROOMS wax 9.0 It14.0 ft 3 RBposed 9h 8.0 ft heat/cod 8.0 It heat1ccol 4 Room dimensions 1.0 x 920 It 13.0 x 13.0 ft 5 Room area 920 ft- 169.0 fP Ty Construction U-value Or HTM Area (ft2) Load Area Load number (BtWVft;-•F) (Btuwft-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat I Cod Gmss WP/S Heat Cool 6 W 13A ws 0143 ne.. 400 255 0 0 0 0 104 88 351 223 1Aclom - 1270 ne 3556 .70.43 0. a 0. 0 0 0 ; 0 .. ` 0 - 1Ac1om .^ -1270. ne.._-..35.66 70.43. .0 0.-.., 0. :'0 ,o' 'o: 0.-' 0 ilActom ; ..1.270 ne 35.56 - ..45.24 `, 0 0, 0 0 - . ' 16 - 0 .. 581 ::739 11 yI I--D MIocs 0.143 se 4.00 255 64 41 165 105 0 0 - 0 .. 0 1100 0390 se 1092 11,31 23 23 248 257 0 0 0 0 yI LG4AS2om 13A4ocs ,.. -0143 sw` ,� �` 4 00 -;.• 255 4 - 1.8 . .' , 8 ' ... 32 ` ... `-20 ..8- 8 32 ,...20. ... ..0.770 .sw' '21.56.. 27:53 0 0 0:. -0 ..- : OI. .0� - 0 '0 �j1 13A4ocs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 I—C 1Aciom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 �--(' 4AS2amd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 12C-0sW - -0.091 ,. .�' `'255 ••tt28' .,.so -.. :88' '224 113. .104:.' �104 '.-: 265,- ..133 C 16A,90md 0.032 - 0.90 232 92 92 82 213 169 169 161 392 !F 22A.tpl." 0.989---' 27.69 .. '0.00:. .. 92 :9' .. : 249 ` ' . 169 14 388 "' ".,--0 6 c)AED excursion -25 S2 Envelope lossfgain 1002 684 1768 1456 12 a) Wi tration 162 46 252 71 b) Roomventilation - 0 0 0 0 13 Internal gains: Occupants Gxa 230 0 0 0 0 ApplianceVother 0 0 Subtotal Qines 6to 13) 1163 730 20M 1527 Less eMenlal load 0 0 '0 0 Less transfer 0 0 0 0 Redstdbutiorl 0 0 0 0 414S'.tbtt.qWt 1163 730 2020 1527Oucloads34% 53% 390 386 34% 53% 677 808Talroom load 1553 11162697 2335 uired (cfm) 73 48 127 100 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed A ' wrightsoft- RlghtSuiteO universal 201717.0.14 RSU08101 2017-Aprd017:19:28 ...k Calcslgocuments\WYNNE-THE WINgSOR-REVISEO.mp Cale = MJB Front gaor.faces: N Page 6 wrightsoft Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4660796 Email: OUCKCALCS@J,OL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250. in H2O 0.273 in/100ft 1160 cfm 183 Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/106ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (In) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 0x0 VIFx 19.5 115.6 stl BEDROOM 2 C 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 stl BEDROOM 3 h 2697 127 100 0.353 6.0 0x0 VIFx 26.8 115.0 all DININGIGREAT ROOM C 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DININGIGREAT ROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 sill DINING/GREAT ROOM c 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 all M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM.A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 OxO VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (In) Material Trunk st2 PeakAVF 612 602 0.273 780 12.0 0 x 0 VinlFlx all Bill Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx EGA+ wrightsofY Right-Sulte(DUnivemal2Ol7l7.0.14 RSU08101 ... k CalcslDocumentslWYNNE-THEWINDSOR-REVISED.mp Calc=MJB Front Doorfaces: N 2017-Apr-10 17:19:29 Page 1 Grille Size (in) Htg (cfm)(cfm) Clg TEL (ft) Design FRI.Veloc (fpm) Diam (n) Hx W (n) Stud/Joist Opening (in) . DuctName Matt I Trunk rb1 Ox0 1 1160 1160 0 1 0 0 0 Ox 0 1 VIFx Jµy wri htsoft 2017-Apr-1017:19:29 9 RightSuite® Univemal 2017 17.0.14 RSU08101 page 2 ... k CalcslDocumentsXWYNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Door faces: N