ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY e��ANNED City, Slate, Zip: FT. PIERCE, FL, Permit Number.. BY Owner: 35 Jurisdiction: y 1 ,, County Design Location: FL, Fort Pierce awl, r,Ucie County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft' b. Frame -Wood, Adjacent R=11.0 208.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft' 6. Conditioned floor area above grade 1753 b. N/A R= ft' Conditioned floor area below grade (112) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 265 a. U-Factor: Sgl, U=0.54 111.36 ft' SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A fN a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.44 PASS Total Baseline Loads: 53.95 I hereby certify that the plans and specifications covered by Review of the plans and STaTB this calculation are in compliance with the Florida Energy specifications covered by this pFZFiE a O Code. calculation indicates compliance with the Florida Energy Code. uur '••• +: = O PREPAg BeBefore construction is completed a DATE: �'` t this building will be inspected for � O y compliance with Section 553.908 I hereby certify that Phis building, as desined is g' compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWNEW BUILDING OFFICIAL: DATE: ` DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/4/2018 2:03 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address • Building Type: User Conditioned Area: 1753 Lot # -Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY. 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' __ 0 1 0 4/4/2018 2:03 PM . EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 It 0 180 ft2 __ 0 1 0 7Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' — 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft' — 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 It 0 50 ft' ___ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 it 0 25 ft' __ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 it 0 92 112 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 it 0 169 ft' — 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft' 0 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N ' CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 it' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft' 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 fill 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft' 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below a 1 NE=>W Exterior Concrete Block - Ext InAlASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 2 SW=>E Exterior Concrete Block - Ext InddASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InddASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 _ 4 NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 4/4/2018 2:03 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below -5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 -6 NE=>W Exterior Concrete Block - Ext IndIffDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 _ 7 SW=>E Exterior Concrete Block- Ext InQINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext In3dINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext InMEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.4 0 DOORS #•4 Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 4/4/2018 2:03 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # 'Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / -- Supply — — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 265 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: C[reiling Fans: Heating ']Y [[ ]] Jan Feb [X] Mact r [ j L AApr May �MayX� Jun �X� [I Sep fr r Dec Venting [ 1 L 1 Jan [ ]Feb [X] Mar l l l [ Jun Jul [X� Aug [Xj Sep l Occtt Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/4/2018 2:03 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, Stfflte, Zip: FT. PIERCE, FL, Permit Number: Owner' Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Dining and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrirallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. • I Caulking or other adhesive sealants shall not be used to fill voids between fire qn(inkler cover plates and wallq or neilinas a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/4/2016 2:04 PM EnergyGauge® USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case? .' Yes 6. Conditioned floor area (tt') 1753 7. Windows" Description Area a. U-Factor: Sgl, U=0.54 111.36 ft' SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft' SHGC: SHGC=0.25 c. U-Factor: N/A ft' SHGC: d. U-Factor: N/A ft' SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' b. N/A R= ft' c. N/A R= ft. 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft' b. Frame - Wood, Adjacent R=11.0 208.00 ft' c. N/A R= ft' d. N/A R= ft' 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft' b. N/A R= ft' c. N/A R= ft' 11. Ducts R ft' a. Sup: Attic, Ret: Attic, AH: Attic 6 265 12. Cooling systems kBtu/hr Efficiency a. Central Unit 34.8 SEER:15.00 13. Heating systems kStu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 14. Hot water systems a. Electric Cap: 40 gallons EF: 0.97 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant fe s- Builder Signature: Date: Address of New Horn\\o City/FL *Note: This is'not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label Wquired by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/4/2018 2:03 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 -- wrlightsoft= Project Summary SCAB Date: Entire House By By: QUICK CALCS, INC. s Lucie:coprI ty 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-466-6799Fax 772-46"796, Erro9:. 0UICKCALCMAOL.COM Project• • For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: 3' ) c, `�� 7 Weather. Winter Design Conditions Outside db Inside db Design TD Fort Pierce, FL, US Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily rang Relative hue midity Moisture difference Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (W) Air changeslhour Equiv. AVF (cfm) Simplified Average 0 He " Co 1751. 14741 14741 0.38 0.20 93 49 Heating. Equipment Summary Make Cartier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 470F 27 OF 1160 cfm 0.047 cfm/Btuh 0.60 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 75 °F 15 OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier Equipmenf sensible load 0.95 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 ofm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual.airflow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -+ wrightsoft' Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-1017:19:28 Ci\ ACPage 1 ...k Celcs\DocumentslWVM�-THEWINDSOR-REVISED.rup Cale =MJB Front Door faces: N wrightsofr Right -A Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE W., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: L]UICKCALCSCcDAOL.COM 1 Room name Entire House MASTER BEDROOM 2 E)posed wall 153.0 ft 45.0 it 3 Room height 8.4 ft d 8.0 ft heal1cod 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft- 280.0 fl' Ty Construction U-value Or HTM Area (ft� Load number (BtulJfti°F) (BlulJft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross WP/S Heat Cod Gress WP/S Heat Cool 6 13AAWS 0.143 no 4.00 255 488 448 1795. 1141 192 192 769 489 1Aeiam :' 1270 no- -`35.56. 70.43 7 0 247, '581 -488 . 0; 0. - 0 -,0 1Ae1ona- "•1.270 ne „35.56 :70.43 ." 16-�' ..0 ,',. 1151 0., 0,_. 0 �;, �0 -1Actom- 1.270'-ne. ` 35.56 45;24 i6'.- 0 - 681 - 739. ;0. .0 ,0 ' .' 0 11 yf �D 13A4a 0.143 as 4.00 255 64 41 165 105 -0 0 0 _ 0 1.1D0 0.390 se 1092 11.31 23 23 248 257 0 0 0 0 4y t G 73A-0ocs: - .0.143-sw: .._ `400 .-255 - 437' 396 >1584+-. 1007 .. 56 56. 224, _ ( 140 14A5.2am 0.770 - 21 56 .- "27..53 41 `. 45 , .. ':893 : :1140 0 .. 0 e O :. "- 0 t'1/ I-G 13AAocs 0.143 my 4.00255 290 217 867 551 112 79 318 202 1A-cl m 1.270 nw 3556 45.24 33 0 1162 1478 33 0 1162 1478 ��----GG 0.770 rlw 21.56 36.90 41 0 880 1505 0 0 0 0 P t" _4A5-2omd 12C-0sw' .. 0.091 ,-. 265 -.- ' 1328 308 :. '308 -784 ` 395. :. -0 `. - `�0 0 C 16A30md 0.032 - 0.90 2.32 1753 1753 1571 4067 28g 280 251 , 6'0 F-, .; 22A-tpl : 0.989. --. _ 27.69 0.00 1753 -,153 4237' - :0 260 . 45 1246 :,. ' .'- 0 6 c)AED excursion 1360 600 Ern lope loss/gain 15594 15385 3970 3561 12 a) infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 1 0 Subtotal Qines 6 to 13) 18467 17655 4779 3789 Its wdenal load 0 0 0 0 Less transfer 0 0 0 0 Redistnbution 0 0 0 0 14 Subtotal 18467 176M - 4779 3789 15 Dud loads 340/6 53% 6190 9340 34% 530A 1602 2OD5 Total room load 24657 2fi995 6380 5794 Air required (cfm) 1160 116D 300 249 -"d- wrightsoft A a1201717. RS108101 ...kCalu\Documnts\WVNNE-TFEWINDSOR-REVISED.Np Calc=MJB Ffont Door faces: 2017-Apr.10 17:19:28 Page 1 + wrightsiO RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 F= 772-466-6796 Email: QUICKCALCSPAOL.COM 1 Room name WIC M. BATH 2 Famed wall 0 ft 7.0 ft 3 Reom height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 61.0 ft' Ty Construction U-value Or HTM Area Load Area Load number AhIff"F) (Btuhlft2) or perimeter (ft) (Btuh) or pedmetter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 Im 13A4ocs 0143 no 400 2.55 0 0 0 0 56 49 196 125 11Aclom ' `1Ac1om•�i 1.270 no, 3556 ' .70.43 0 0 0 .0 7' " 0 247, 488 .:1270 ne, .3556 - 70.43 0 -.- . -.0 :.. 0.. 0.. -. 0- 0 .. 0 - +_o 1As1om , 1.270 , ne ;-'-35.66 '45i24 . 0 ..,0 -0, 0 0 0 0 .; 0 11 W 13A-4ocs 0143 as 4.00 2.55 0 0 0 0 0 0 0 ; 0 11D0 0.390 as 1092 11.31 0 0 0 0 0 0 0 0 _ 4y 13A4ocs: M1:a2om .:.' 0.143 sw :. -; '400 ;.,• 2:,55 ,0 =-- 0: < - o'.... . _... :O.770 sw :..- 21.56 ' Z7.53 . 0 " o - o 0 o . o `: o ... ) o 4dl IL-l�e1Acicm 13A-0ocs 0.143 my 4.00 2-55 0 0 0 0 .� 0 0 0 0 1270 nw 35.56 45.24 0 0 0 0 0 0 0 0 `' 4A5-2omd. .. 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P , g2C-(sw.:. 0.091 ...,- -:,:,255 "'. 1[28 ': . '0 .0- 0. - 0 ' ' .0 .0 '.0 •0 C 'F ' 16A30md 0.032 - 0.90 232 63 63 56 146 fail fail 55 142 27A-tpl . 0.989 - •.27.69 '. '.0.00 63 0 0 0' . '61 . '7 - - 194 , , ..0 6 c)AEDeleursion 5 -26 Ss lope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 Applianceslother 0 0 Subtotal pines 6 to 13) 56 141 817 764 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 66 141 817 764 15 Duct loads 34'/u 530/6 19 75 34% 53%1 V4 404 Total room load 75 216 1091 1168 Air required (cm) 4 y 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoft- 2017-Apr-1017:19:28 �p RightSufte® Universal 201717.0.14 RSU08101 Page 2 ...k Calcs\Documents\WYMVE-THE WINDSOR-REVISED.mp Calc=MJB Front Door faces: N wrightsoft- Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317ST.. LUCIE LM,FT. PIERCE, FL34946 Phone: 772-46"799 Fax 772-466-6796 Email: 0U1CKCALCSf)AOL.COM 1 Room name LAUDRY BEDROOM 2 2 EVosed wall D ft 120 ft 3 Room height 8.0 If heaUcool 8.0 ft heattccd 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 ft 5 Room area 36.0 ft' 180.0 it' Ty COMmIctim U-value Or HTM Area (ft') Load Area (ft-) Load number (BtuWfti°F) (BtuWft l or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gross I WPIS Heat Cool 8 W 13A = 0143 ' ne 4.00 2.55 C 0 0 0 96 80 319 203 -;1Ac1cm ' .1270 ne. :35.56 -70.43 0 -.. -0 . 0 .0 ' .. 0 , 0 - D 0 ,1Actom,,. `:tAclom 1270. ne 3556 :70.43' 0- 0 0.- ' 0 16•. 0 681 . 1151� 1.270 . ne .. 35.66 45.24 - 0 , 0 0 ,0 0 0 - - 11 W 13A-0ocs 0.143 se 4.00 255 0 0 0 .' 0 0 0 .6 0 .".: :0 0 -D 11Do 0390 so 1092 11.31 0 0 0 0 0 11 0 0 1-G 13A4acs ^. --- �4As2cm ` 0143 sw' .=''4.00 ' 265 -27.53' - 0 0. 0 '. _ 0. 0 - 0 -�- 0 0.770 sw. .:z1.56 '_' 0... .:0 p , ,p p'. p . 0 .,'0 W 13A4ocs 0.143 my 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 II-----GG 4A5-2cmd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ;12C-0sw- 0.D91' - ."2.55' `1'28 .' 0 .0 0 0.' 0 .0, - ' 0 - 0 C 16Aa0md 0.032 - 0.90 232 36 36 32 84 180 180 161 418 F ..:... 22A4pl . :... 0.989 -; 27.69 .0.00 36 0 0 ' <0 . -- 180 .. , 12 .- 332 . -': , 0 6 c)AED elcurslon S -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0, 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less mdemal load 0 0 0 0 Less transfer 0 0 0 0 Red�stdlMion 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Dud loads 34% 53% 13 50 34% 63% 541 9,15 Total room load 51 145 21M 2730 Air required (dm) 2 6 101 117 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wrightsoft- 2017-Apr-1017:19:28 p RightSuiteO Universal 201717.0.14 RSU08101 Page 3 ...k CalcslDocumems1WYMVE-THE WINDSOR-REVISED.rup Cale =MJ8 Front Door faces: N wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 Famed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat(cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 It 19.0 x 11.0 ft 5 Room area 588.0 It- 209.0 fN Ty Construction U-%dlue Or HTM Area 00 Load Area (ftj Load number (BtutJffvF) (BtuNftl or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cccl Gross WP/S Heat Cool Gross WP/S Heat Cool 6 i3A4= 0.143 ne 400 255 0 0 0 0 0 0. 0 0 AAclom - lX0 no 3556 70.43 0 .0 0 0 0 0 0 _0 1Ac1om 1270 ne' -.'3556 i 70.43 0 ". 0. .. 0" a 0 "0 :. 0.. 0 �.'...0 1Aciom:^. ' 1:270 -ne" .`'35.56 ' 45.24 :0 0 0 0 0 .. 0 - 0 0 11 V�1 13AAacs 0.143 se 4.00 255 0 0 0 0 0 0 -D 1100 , 0.390 se. 1092 11.31 0 0 0 0 0 0 0 0 "- 13A4ocs';: _ - .-0143 -SW, <"400 - 255 ,. 297 226 ` .: �;.503 . � _. �574 98 ;. - .:98 .. 392 _ � . .249 �1620m . . 0;770 sw . 2156 ., 27.53 41 22 893 =. 4140 -0 0 ` A -`.0 13A4acs 0.143 nw 400 255 178 137 549 349 0 0 0 0 1Aclonn 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2ornd 0.770 my 21.56 36.90 41 0 880 1505 0 0 0 0 �12C-0sw- .., 0.091 .-' 2.55 1:28," 0 . 0' 0 .0 , :116 118 _ ". 295 : " 148 C 16P,30md 0.032 - 0.90 232 588 588 527 1364 209 209 187 485 F: .,. 2.. 22Xtpl 0.989 -'- 27.69 ',.0.00 588 _ 50 ` . '1385 0 209' ... 11 •. 305 •:: -;.0 6 c)AM excursion 1004 -64 Envelope loss/gain 5136 6937 1179 818 12 a) hfiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Applianceslother 0 low Subtotal Qires 6 to 13) 6136 66ml 1399 . 1880 Less exoemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6893 1399 1880 15 Duct loads 34% 63% 2058 3541 34% 53% 469 995 Total room lead 8200 10239 1867 2875 Alr required (cfm) 386 440 88 124 �6A'� wriiihtsoft• RlghtSuite® Unhmmal 201717.0.14 RSUD8101 ...k CalcslDocuments%WYNNE-THE WINDSOR-REVISED.rup Cale =MJ8 Front Door faces:N 2017-Apr-10 17:19:28 Page 4 wrightsoftRight-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; 772466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOLCOM 1 Room name BATH HALL 2 F�rprsad wall. 5.0 ft Oft 3 Room height 8.0 It heallcool 8.0 It heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ft. 25.0 W Ty Construction U-value Or HTM Nea Load Am number (Btuh/WF) (Btulvft� cr perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat TCd Gross WP/S Heat Cool Gross WPIS Heal Cool 6 134-0ocs 0.143 ne ,400 255 40 40 160 102 0 0 0 0 ;1Ac1om -_ .,1X410M t ,1:270 " 1:270 ne -..3556 -3556 ,70.43 0 0 ;0 .. .0 0-. 0, 0 `0 ,'10 ";:0 ,1:270 ne. .70.43. .0 0 � •..0 • 0 0 L:. .0 :- :. tlActom • ne.. 35.56 ,:45.24 0 0 0 ' p p p ., :. �:p 11 W 13A ccs 0.143 se 4.00 255 0 . 0 _ 0 .0. 0 0 0 0 , 0 11130 0.390 as 1092 11.31 0 0 0 0 0 0 0 0 •. ]A5-26m..0;143 ' sw � =400 - ;255., �'' .: 'a- , g:-'-... 0+" .r°-0a .. p,-- p :. ;p 13AAoc . -.. ....0.770 .sw. .'21.56 27.53' 0': - 0 0 _:0 , 0 - 0 0 10 `. 0 �1 13A-0acs 0.143 nw 4.00 255 0 0 0 0 0 . 0 0 .. 0 I--�' 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 �—C 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P,1". 12C-0sw •. 0.091 '- 255- .1.28 - 0 :0 - 0 0' "0.." '0-.• 0"- •0 C 1BA30md 0.032 - 0.90 232 50 50 45 116 25 25 22 58 ,F 22Atpl' 0.989i - Z7.0 .0.00 '50 5 :-138: 0 - 25' a 0 ,ip 6 c)AEC eoeursion -g .p Fmelope loss/gain 343 210 22 56 12 a) filtration 90 25 0 0 b) Rcomventilation 0 0 0 0 13 Internal gains: Occupants aQ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 433 Pig 22 56 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 14 Subtotal 439 249 0 1% 0 15 Duct loads 34% 53% 147 - 132 340A 53% 0 0 Total mom load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wrightsofV 2017-Apr-1017:19:28 RlghtSuite® Uniwmal 201717.0.14 RSUDS101 Page 5 ...k Cslcs1D0cumentslWYNNE-THE WINDSOR-REVISED.mp Cale = MJ8 Front Door faces: N wrightsoft- Right-J® Worksheet Job: Entire House pate: QUICK CALCS, INC. ay. 317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772468-6799 Fax 772-4660796 Email OUICKCALCS@A0LC0M 1 Room name FOYER BEDROOMS 2 EVosed wail 9.0 ft 14.0 ft 3 Room height 80 It heallcool 8.0 It heaticud 4 Room dimensions 1.0 x 920 It 13.0 x 13.0 It 5 Room area 92.0 ft- 169.0 ft. Ty Construction U-value Or HTM Area Load number (BtuWfti°F) (Btu[Vft') or perimfeter (ft) (Btuh) or perimeter (It) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Vh13AA= - - 0143 no 400 255 0 0 0 0 104 88 351 223 :1Actom '" 1270 ne-: -3556 .70.43 0. 0 0. .0 0 0 0.-0 ;1Aclom .,` 1270.ne. 3556 70.43 10 0:. 0 _-0 ,0 -' 0 , 0 :tAclom �; -1.270 ne 35 66 :.4 5.24 . ..0 " A °0 '0 16 - - 0, - 581 '739 11 4�/ 13AA= 0.143 as 400 2.55 64 41 . 165 105 0 0 0 0 �D IID0 _ 0.390 se �SW 1092 11.31 23 23 248. 257 0 0 0 0 -0.143 `r400 %'_- 255 r..- 8. 8.' - 32 8 ;. 8, 32 20 LC '4AS-2am ... - 0.770 _sw.. -21.56 .27.53 - 0 0 0. . 0 _ : 0' ,0:. 0 13A4acs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270 rnv 35.56 45.24 0 0 0 0 0 0 0 0 . 4AS-2omd 0.770 my 21.66 36.90 0 0. 0 0 0 0 0 0 P .12Mw 0.091 . -. . "`2.55 1.128 -. ..88 ... :88 - "224 113 ` . "104 - -104 - - 265 - ` 133 C 18A30md 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 .F • ... 22ktpl,' 0.989 > = 27.69 .. .-0.00 92 9 .. 249 .0 169 -. 14 .. ^388 ,.' ... 0 6 c)AED mursim -25 ,M Envelope loss/gain 1002 69 1 1768 1456 12 a) hfiltratlm 162 46 252 71 b) Rcom ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 Appliancesrother 0 0 Subtotal Qines 6 to 13) 1163 730 2020 1527 Lass eMelnal load 0 0 0 0 Less transfer 0 0 0 0 Red�sldbution 0 0 0 0 14 subtotal 1163 730 2020 1520 15 Duct loads 34% 53% 390 386 34% 53% 677 808 Total room load 1553 ills 2697 2335 Air requfred(cfm) 73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A '�- wrightsoft- Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-10 17:19:28 ... k CalcslDocuments%WYNNE-THE WINDSOR-RMSED.mp Calc = MJ8 Front Doort)ces: N Page 6 Duct System Summary Job: wrightsoft® y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE M, FT. PIERCE, FL 34946 Phone: 772-4686799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/.return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0,250 in H2O 0.273 in/100R 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diann (In) H x W (n) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.0 st1 BEDROOM c 2730 101 117 0.384 7.0 0x0 VIFx 15.0 115.0 SH BEDROOM h 2697 127 100 0.353 6.0 OxO VIFx 26.8 115.0 st1 DININGIGREAT ROOM c 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DININGIGREAT ROOM-9 C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DININGIGREATROOM-C C 3411 129 147 0.278 7.0 0x0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 SIM M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 . 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 wo o 216 4 9 0.292 4.0 OxO VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diann' H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVFJ:6�IT�2602 0.273 780 120 0 x 0 st1 st1 PeakAVF01112 0.273 796 16.0 0 x 0 Fix lx C +�F wrightsofC 2017-Apr-1017:19:29 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1 ... k Calcs\Documents\WYNE-TFiEWINDSOR-REVISED.mp Calc=MJB Fmnt Doorfaces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Oz0 1 1160 1160 0 1 0 0 0 Ox 0 VIFx EGA+ wrightsoft' Right -Suite® Universal 201717.0.14 RSU08101 ... k CalcslDocumentalWYNNE-THEWINDSOR-REVISED.wp Calc=MJe Front Doorkces: 2017-Apr-10 17:19:29 Page 2