HomeMy WebLinkAboutEVALUATION REPORTq'
G R K
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization 29824
SCANNED 17520 Edinburgh Drive
Tampa, FL 33647
BY (813)480-3421
St. Lucie Cou*
FLORIDA BUILDING CODE, 6Te EDITION (2017)
Manufacturer: OWENS CORNING ROOFING
AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657
(800)438-7465
www.owenscornina.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Undedayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
Enti
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST5878)
NEI-039-02-01
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 165
2005a
PRI Construction
Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
NEI-053-02.01
ASTM G 155
2005a
PRI Construction
Materials Technologies (TST5878)
NEI-093-02-02
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction
Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction
Materials Technologies (TST5878)
OCF-252.02.01
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
OGF-296-02-02
]CC -ES AC 188'
2012
ICGES AC 48
2012
PRI Construction
Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF318-02-01
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction
Materials Technologies (TST5878)
OCF-32"2-01
ASTM D 1623
2009
PRI Construction
Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09, Type I
and II
OCR14002.8a FL9777-RI I Pads 1 of 4
This evaluation report is provided for Stale of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Seating Ice & Water Barriers
WeatherLock® G
WeatherLock® G is an ASTM D 1970 self-adhesive undedayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied In 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Mat
WeatherLock® Mat is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, T)Q
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Metal
Weatherl-ockk@ Metal is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. mlls with nominal dimensions of 3-11 x 66.7-ft.
WeathefLockO Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLockO
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive undedayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, T)Q
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONDm Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maxtinum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete file installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G (High
WeatherLock® G (High Tear) is a self -adhered, undedayment used as an alternative to
Tear)
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston, T)Q
modified bitumen underayment. The underayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a
FL9777-Rll
2 of
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All undedayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. Ali
fasteners in the deck shall be checked for protrusion and corrected prior to undedayment
application. Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The undedayment shall be installed with the release backer removed and pressed firmly
Into place to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starling at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
be Installed perpendicular to deck with the nail heads flush to the top surface of the
undedayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40"F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
Undedayment System No.1 — WeatherLock Specialty, Tile & Metal Only
Roof Deck: Min. 15/32-inch COX plywood attached to wood supports spaced a maximum 24" o.c.
Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturers installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through .
optionally primed, 32ga. x 1-5/8-inch 0 tin raps spaced 12" o.c. The applied
undedayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.6a F1.9777-R11 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl-ock® Self -Sealing Ice & Water Barriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall bedetermined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underiayment shall meet or exceed the design wind loads
determined for the roof assembly. .
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
P`,`t1RYi,Rprr�4
,O G1aP A/�ii�
�ZCENSfi.iP10
No74021
9 STATE OF
CERTIFICATION OF INDEPENDENCE
2017.10.
09:06:29
.._ . A _04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have,. nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R Priest, P.E. does not have, nor will acquire, a financial interest is any other entity involved in the approval process of the
Product
END OF REPORT
FL9777-R11
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not