HomeMy WebLinkAboutPRODUCT APPROVAL{, MAY 15 2019
. u k i^
ST. Lucie County, Permitting
BCIS Honor log In User Re9tstraton Hot Topia Su➢mR SUMiarga suits a F101 Publications C➢ntact Us aCts Ate Map Units Searca
bWA Product Approval
r USER: Fu➢(k User FroaurtAbp.cvalMnu>a FILE COPY
„[q�'uSi,�3rFllltyt_rLj�rch > c.^A1Catia4L?&> Appllwtlon petail
FL #
FL1654-R23 2.C4
Application Type
--0
Revision in I
(��
Code Version
2017 - 1
R VIEWED FOR
Application Status
Approved-. CODE COMPLIANCE
Comments
S 1T. LUCIE CO
.Archived
p
®OCC r
Product Manufacturer
POLYGLASS VSA
Address/Phone/Email
1111 W. Newport Center Drive ��
Deerfield Beach, FL 33442 SCANNED
IY111
(9S4) 233-1330 Ext 242 Ip
B
FV
malpert@polyglass.com
St. Lucie County
Authorized Signature
Maury Alpert
malpert@polyglass.com
Technical Representative
Maury Alpert
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAlpert@polyglass.com
Quality. Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation.Report
Florida.Lfcense
PE-59166
Quality Assurance Entity
UL LLC
Quallty.Assurance Contract Expiration Date
09/1312021
Validated By
.John W. Knezevich, PE
v Validation Checklist - Hardcopy Received
Certificate of independence
Referenced Standard and Year (of Standard)
Standard
YM
ASTM D6162
2008
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
UL 1897
-2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL # E Model, Number or Name
1654.1 m Polyglass 585 and APP Modified
Bitumen Roof Systems
Limits of Use
Approvedfor use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this application
relates to one particular assembly over concrete deck.
Refer to the ER Appendix for other systems and deck
types. 2.) Refer to ER, Section 5 for other Limits of
Use.
Method I Option D
10/08/2018
10/13/2018
10/21/2018
12/11/2018
Description
SBS and APP modified bitumen roof systems
Installation Instructions
FL1654 R23 11 2018 10 FTNAI. Al FR POIYCI A55 4 Q IT F1,.1654-
R23 Ddf
Verified By: RobertNieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
ELIE54 R23 AE 2018 30 FINAL ER POL"GLASS MODBIT F1 tfi54-
l3Li.adf
Created by Independent Third Party: Yes
0 0
Conuct Us :: 2601 elar Stone Rnad call+ a� ee Ft 12 99 Pnonc 95�-467-1 R24
The state of Florida is an AA7EED emalover. t9¢vLoht 2097.20t3 Sttte c! donda ;: on,,nry Sut'!"j A, ;; R nd cut men,
Under Florida law, email addresses are pubic records. It yar po not want your a -mail address released in response to a public-reeards mqumt, 90 not send electronic
mail to this entlry. instead, contact the Circe by phone or by traadonal mall. It you have any questions, please contact 850,481.1395. •Persuantto Secthm 4S5.275(1),
Florida Statutes, enactwe DRober 1, 2012, licensees licensed under Chapter 455, F.S. must provde, the Department with an email address It they have one. The emails
provided may be Used for Off dal Comm micatJon with the I:eensee. However email addresses are publlc record. If you do not wish to supply a Personal address, please
Provide We Department with an toned address whkh can be made available to the public. To determine it yoir are a nomsee under chapter 455, F.S., please Ciit# be=.
product Approval Accepts;
M1 G2F,l 0
.SL:Curit� Atl?RI�.0
ONEmoletc.
APPENDIX 1:
ATTACHMENT REQUIREMENTS
DECK •
UPLIFT RESISTANCE
, APPLICATION
TYPE
DESCRIPTION
PAGE
TABLE
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
SC
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1D
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
12
lE
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-14
1F
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
15-17
1G
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
18-21
1H
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
21-25
11
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
26
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Tap Insulation, Banded Roof Cover
27-29
28
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Banded Roof Cover
30-34
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
35-37
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
38-46
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
46
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47-49
4B
Lightweight concrete
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
50
4C
Lightweight concrete
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
51-53
5A
Cementitious wood fiber
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
54
SB
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
55
Sc
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
56
SO
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
56
5E
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
56
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
57-59
6B
Existing gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
59
6C
Existing gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
60
6D
Existing gypsum
Reroof (Tear -Off) or Recover
E
Nan -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
60
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
61-65
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
65
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/ base sheet fasteners shall be of sufficient length for the following deck engagement:
D Wood: Minimum 0.7S-Inch penetration.
➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-Inch embedment Into pilot hole in accordance with fastener manufacturer's published installation instructions.
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-R23
Certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglaw Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 65
ONEM01letc.
3. Unless otherwise noted, Insulation maybe anyone layer or combination of polyisocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the OA requirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete maybe substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the bases heet
fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural
members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck.shall be documented through proper codified and/or FBC Approval
documentation.
S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published Instructions.
➢ Hot asphalt (HA): Full coverage at 25-30lbs/square.
D Dow INSTA STIK Cuik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-Inch wide ribbons,12-inch o.c.
D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c.
D Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or Spotshot). Note: OlyBond Green maybe used where OlyBond 500 is referenced.
D OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
D ICP Adhesive& Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
D Note: When multiple layersis) of insulation and/or coverbaard are Installed in ribbon -applied adhesive, board joints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation boardshall be not less than one-half the specified. ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MOP listings in the tables; rather if MOP listing below meets or exceeds that listed for a particular system in the tables, then the
thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
D Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M.PGI): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (OB500): MOP -187.5 psf (Min. 0.5-inch thick ISO 95+GL)
D OMG OlyBond 500 (011500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3)
D ONG OlyBond 500(OB500): MOP -487.5 psf (Min. 0.5-inch thick ACFoam 11)
➢ ICP Adhesives & Sealants Polyset CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polyisocyanurate Insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WC1, FM Loss Prevention
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RA5137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates Ina bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the. satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the Insulation is optional; however, the existing roof system shall be suitable for a recover application.
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-R23
Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21; 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 65
ONEMOletc.
14. Lightweight Insulating Concrete (LWC) shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat
thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast
using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, In accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted,
use of these listings in new construction or re -roof (tear -off) applications Is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications
PoLYGLAss ROOF COVERS
REFERENCE
LAYER
I MATERIAL
APPLICATION
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type If
(Base and Ply sheets,
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Hot Asphalt at 20-40
Ibs/square
Asphalt -Applied)
Note:
Asphalt -applied sheets or insulation shall not be applied to polyjilm surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 Type II, Polyglass HT Base 650
PG350 at 1.5-2.0
SBS-vat
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II
Polyplus 35 at 1.5-2.0
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex
SBS-AA
Base Ply or Ply
56 Type II, Polyglass HT Base 650
Hot Asphalt at 2G-40
(SBS, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets orinsulation shall not be applied to poly -film surfaced membranes.
or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base
SBS-TA
Base Ply or Ply
650
Torch -Applied
(SBS, Torch -Applied)
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-
Cap Ply
G, Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, PolyrefleR
Self -Adhering
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SOS -SA Base Ply options herein,
Elastobase (poly/sand) or Elastobase (poly/poly).
PG350 at 1.5-2.0
APP-CA1
Cap Ply
Polyflex G FR
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
Torch -Applied
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP SA
Note:
Unlessotherwite noted, permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
(APP, Self -Adhering)
Elastobase (Poly/sand) or Elastobase (poly/poly).
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-RZ3
Certificate of Authorization #32455 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 65
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation Carry the following Maximum Design Pressure (MDP) limitations.
applies:
ONEMOjetc.
The lesser of the MDP listings below vs. those in Table 3A
OPTION
#
..PRIMER
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRnE DECK; ADHERED
VAPOR BARRIER
I NSUILATION PER TABLE 3A
-
INSULATION ADHESIVE
MOP(PSF)
TYPE
ATTACH
VB-1.
PG300
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-Inch D.C.
-60.0
VB-2.
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20, 12-inch D.C.
-75.0
VB-3.
PGS00
Elastoflex SA P
Self -Adhering
Insta-Stik, 12-inch D.C.
-75.0
VB-4.
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamable Adhesive, 12-inch D.C.
-157.5
VB-S.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-Inch o.c.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch D.C.
290 0
17. The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for
application limitations and a Roofing Materials Directory for fire ratings associated with coating usage.
SURFACING OPTIONSMODIFIED •• F SYSTEMS
Option#
Florida Product Approval
SURF-1.
PG300 Fibered Roof Coating
FL10291
SURF-2.
PG600 Non-Fibered Aluminum Roof Coating
FL10291
SURF-3.
PG650 Fibered Aluminum Roof Coating
FL10291
SURF-4.
PG700 High Quality Elastomeric Roof Coating
FL10291
SURF-5.
PG700CLS (Quick Set) High Quality Elastomeric Roof Coating
FL10291
SURF-6.
PG800 Asphalt Emulsion Roof Coating
FL10291
SURF-7.
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating
FL10291
SURF-8.
Polyplus 65 Premium Fibered Aluminum Roof Coating
FL10291
SURF-9.
Polybrite 70 Premium Grade Elastomeric Roof Coating
FL10291
SURF-10.
Polybrite 70QS(Quick Set) Premium Grade Elastomeric Roof Coating
FL10291
SURF-11.
Polybrite 71 HS
FL10291
SURF-12.
Polybrite 90 High Solids Silicone Roof Coating
FL10291
SURF-13.
Polybrite 95 Silicone Roof Coating
FL10291
SURF-14.
KM Acryl 15
FL27409
SURF-15.
KM Acryl 15 CIS
FL27409
SURF-16.
KM Acryl 25
FL27409
SURF-17.
KM Acryl 25 CIS
FL27409
SURF
M A0 HS
FL7098.
KMAcryl4
FL7409SURF-19
SURF-20.
KM PS4250
FL27409
SURF-21.
KM PS#220
FL27409
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-R23
Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 65
NNEMOletc.
TABLE 11: ....REROOF (TEAR -OFF)
SYSTEM TYPE F: . BONDED ROOF
System
Deck (Note 1)
Primer
Roof Cover (Note 15)
MOP (psQ'
- Joint Treatment
Base Ply
Ply -
capply.- _
No.
V-170
Min. 15/32-
None
None
SBS-SA
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-90.0
—foch plywood
TA APP TA
TA APP TA
W-171
Min. 15/32-
(Optional) P6100
None
Polyflex SA Base
(Optional)APP-TA
APP-TA
-90.0
inch plywood
W172
Min. 15/32-
PG100
None
SBS-SA
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
975
inch plywood
TA, APP-TA
TA, APP-TA
Min. 15/32-
Plywoodjoints are covered with flinch wide strips of Elastoflex SA V Plus, rolled Into
Elastoflex SA V Base or
(Optional) 5B5-SA, SBS-
SBS-SA, APP-SA, SBS-
W-173
inch plywood
(ODtional)PG300
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA,APP-TA
-97.5
W174
Min. 15/32-
POLVBRITE 745
None
SBS-SA
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-105.0
Inch plywood
TA, APP-TA
TA, APP-TA
Min. 15/32-
Plywoodjoints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W-175
inchplywood
(Optional)PG100
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
-135.0
W-176
Min. 15/32-
(Optional)PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SAV Plus, rolled into
poly0ex SA Base
(Optional)APP-TA
APP-TA
-135.0
inch plywood
place to create continuous bond.
NEMO ETC, LLC
Certificate of Authorization #32455
Prepared by: Robert Nieminen, PE-59166
GTH EDITION (2017) FBC NON-HVHZ EVALUATION
Polygiass Modified Bitumen Roof Systems; (954) 233-1330
Evaluation Report P9290.02.08-R21 for FL1654-R23
Revision 21:10/08/2018
Appendix 1, Page 26 of 65
RECEIVED
MAY 15 2019
M Lucie County, Permitting
12
ECTS Home Login User Registndon I Hot Topics Submlt SurNaMe 1 Stats&Facts; Publications I FBC Stan I &CISSite Map Links Search IfProduct Approval SCANNED
�r 0USER: Public User �s Lucie
Luce County
En�r.w3ki i ps
ty
Product Aonmval Menu > Pmoutt m Application Search > Application LKt a Application Detail St.
yt �i
FL# FL9777-R11
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg. keeler@ owenscoming.m m
Authorized Signature Greg Keeler
greg. keeler@owenscoming. com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
- Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke Bowden
Y' Validation Checklist - Hardcopy Received
Certificate of Independence
FL9777 R31 COI OCR14002 8a 2017 FBC Evaluation Report We th l k
Non-HVHZ.odf
Referenced Standard and Year (of Standard) Standard Vear
ASTM D 1970 2015
ASTM D 226 2009
ASTM G 155 2005
TAS 103 1995
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/11/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
FL fi
Model, Number or Name
Description
19777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9777 Ril 11 OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ odf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ odf
Created by Independent Third Party: Yes
9777.2 Weather -Lock G (High Tear)
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use,
FL9777 Ril 11 OCR14002 8a 2017 FBC EvaluatoR�,00rt
Weatherlock Non-HVHZ.odf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ
pdP
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Undedayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL9777 RII IT OCU4002 8b 2017 FBC Evaluation Report
Weatherlock HVHZ.odf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Party: Yes
Evaluation. Reports
FL9777 Rll AE OCR14002 8b 2017 FBC val ation Report
Weatherlock HVHZ odf
Created by Independent Third Party: Yes
9777.4
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9777 1111 It OCR14002 Ba 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other. See evaluation report for limits of use.
Weatherock Non-HVHZodf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 RSS AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ odf
Created by Indepentlent Third Party: Yes
9777.5
Weatherlock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9777 Rl1 II�Q02.8a 2017 FBC Evaluation R port
Approved for use outside HVHZ: Yes
Weatherlock Non-HVH7 odf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest PE-74021
Created by Indepentlent Third Party: Yes
Evaluation Reports
FL9777 1311 AE OCRI4002.8a 2017 FBC Evaluation Report
Wotberlock Non-HVHZ.Pdf
Created by Independent Third Party: Yes
9777.E
Weatherlock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: No
19777 R31 11 O R1400 Rh ant r•ar Evaluation Rcnnrf
Weatherlock HVHZ odf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation reportfor limits of use.
Verified By: Zachary R. Priest PE-74021 -
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R11 AE OCR14002.86 2017 FBC Evaluation Report
Weatherlock HVHZ.Ddf
Created by Independent Third Party: Yes
Weatherlock Specialty Tile & Metal I Weatherproofing Underiayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-142.5
Other: See evaluation report for limits of use.
Installation Instructions
FL9777 R11 II OCR34002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.Pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 Rl I AE OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf
Created by Independent Third Party: Yes
0ac9 Nsxt
connect Us:: 2601 Blair Stone Road. Tallahassee 3299 Phone: 850-487-1824
The states of Florida is an ANEW employer. copyright 2007-2013 State of Florida.:: Nivocv Statement :: pccesslhiliN Statement r. Retvnd Stamment
Under Florida law, email addresses are public records. If you do net want your e-mall address released In response to a puh0o-records request, do not send electronic
mail to NB entity. Instead, contact Me office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant re Section
455.275(1), Fiends statutes, effective OCMber 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the publla To determine If you are a licensee under chapter 455, F.S.,
please dick here .
product Approval Acccpb:
®®®IM
• a
it`Cll rli`t'AOTIiit.'S