HomeMy WebLinkAboutEVALUATION REPORTTECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Plants:
Quality Assurance:
Certificate of Authorization No. 29824
SCANNED
St. Lucie County
17520 Edinburgh Dr
Tampa, FL33647
(813)480-3421
FLORIDA BUILDING CODE GP EDMON
BORAL ROOFING LLC T alss ct 1018
75751rvine Center Drive RECEIVED 1 L P
Irvine, CA 92618
(800) 669-8453 MAY 15 2019
Lake Wales, FL ST. Lucie County, Permitting
Okeechobee, FL REVIEWED FOR
PRI Construction Materials Technologies (QUA91 10) CODE COMPLIANCE
SCOPE ST• LUCIE COI
Category:
Roofing
Subcategory:
Roofing Tiles
Code Sections:
1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3
Properties:
Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift
Resistance
REFERENCES
ED&
Report No.
Standard
Year
American Test Lab of South Florida Inc (TST3782)
RT0130.01-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0426.01-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0615.02-11
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0615.03-11
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0615.04-11
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0617.02-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0617.03-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0617.04-16
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0623.04-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT0624.04-14
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (rST3782)
RT0624.05-14
, TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT1210.02-15
TAS 112
1995
ASTM C 1492
2003(2009)
American Test Lab of South Florida Inc (TST3782)
RT1210.03-15
TAS 112
1995
ASTM C 1492
2003(2009)
Miami -Dade BCCO (CER1592)
14-0408.06
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
14-0416.12
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
15-0721.04
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
16-0112.07
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
16-0112.08
FBC (HVHZ)
2017
MiamFDade SCCO (CER1592)
18-0509.15
FBC (HVHZ)
2017
MiamFDade BCCO (CER1592)
18-0509.16
FBC (HVHZ)
2017
Miami -Dade BCCO (CER1592)
18-0509.17
FBC (HVHZ)
2017
Tile Roof Institute
Membership Confirmation
TAS 100
1995
TAS 101
1995
TAS 102 8 102(A)
1995
BOR18003
FL28328
Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Bermuda (Okeechobee)
BORAL ROOFING LLC
Concrete Roof Tiles
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, dass III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16" x 10"
BOR18003
j 16' r
Figure 1. Bermuda
FL28328
2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20J. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
&,REEK BORAL ROOFINGLLC
Concretee RoofRoof Tiles
TECHNICAL SERVICES, LLC
Plantation (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2" x 13"
Figure 2. Plantation
Saxony 900 Slate, Shake and Split Shake (Lake Wales)
Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17" x 13" x 1-5/32" (Slate) or 1-9/32" (Shake and Split Shake)
SAIL HOLES
"''DERLOCK
Figure 3. Saxony 900 Slate
--2-(51ae)
COVERLOCK
BOR18003 FL28328 Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
N—AM HOLES
\4n HOLES
F
BOR18003
c/
Figure 4. Saxony 900 Shake
y �
Figure S. Saxony 900 Split Shake
FL28328
BORAL ROOFING LLC
Concrete Roof Tiles
I-9T-(Shake)
T
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
REEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Estate "S" (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof file
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1 /2" x 13"
Nail Holes
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description: ASTM C 1492, TAS 112 Type 1b, low profile, interlocking, class III concrete roof the
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17.0" x 13" x 2-1/8"
1"
BOR18003
�T
Figure 7. Villa 900
21/8"
i
5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Barcelona 900 (Lake Wales)
BORAL ROOFING LLC
Concrete Roof Tiles
ProfileMescription: ASTM C 1492, TAS 112 Type 1a, high profile, interlocking, class III, 'S' shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 1 T x 13" x 3-5/8"
OVERLOCK
3 5/8'
17
\- f 13•
UNDERLOCK -�
Figure S. Barcelona 900
Galena Spanish "S" (Okeechobee)
Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class Ill 'S' shaped concrete
roof the
Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications
Dimensions: 17" x 10" x 2.7"
Fastener Holes
17"
10"
Figure 9. Galena Spanish "S"
BOR18003 FL28328 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Spanish "S" Nuevo (Lake Wales)
BORAL ROOFING LLC
Concrete Roof Tiles
Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III 'S' shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions- 17" x 9-3/4" x 2-27132"
Fastener
APPLicAnoN METHOD
Holes
I
17"
9-3/4"
Figure 10. Spanish "S" Nuevo
Installation
Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance
Slope:
with the recommendations of the FRSA/TRI Florida High find Concrete and Clay Roof
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction
Roof Deck:
at max. 24 in. span; In the HVHZ, new construction shall be min.19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Underlayment:
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable.
BOR18003 FL28328 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Data for Attachment Calculations for Direct to Deck, Applications
Nominal Weight QM and-
Aerodynamic
Restoring Moments due to Gravity - Nlo (8-Ibf)
Dimensions (I x w)
Multipliers
Direct Deck
Roof Tife
A (fta)
--
1N (Ibf)
I (ft)
w (ft) -
Direct Deck-
-3°:12"
4':12'
-6"A2
6":12"
>7":12"
Application
-
Bermuda
9.7
1.33
0.833
0.205
6.97
6.86
6.71
6.54
6.35
Plantation
11.6
1.375
1.08
0.289
7.79
7.67
7.52
7.32
7.04
Saxony 900
10.9
1.417
1.08
0.315
7.62
7.5
7.34
7.16
6.95
Estate "r
10.0
1.375
1.08
0.289
6.74
6.64
6.50
6.33
6.14
Villa 900
10.9
1.42
1.08
0.315
7.62
7.50
7.34
7.15
6.95
Barcelona
115
1.417
1.08
0.301
7.00
6.90
6.76
6.60
6.42
900
Galena
8.5
1.42
0.833
0.235
6.13
6.03
5.89 1
5.74
5.57
Spanish "S"
Spanish "S"
8.95
1.417
0.8125
0.233
5.93
5.83
5.70
5.56
5.39
Nuevo
Data for Attachment Calculations for Batten Applications
Nominal Weight QM and
Aerodynamic
Restoring Moments due to Gravity -,Mo (ft-lbf)
Dimensions Q x w);
Multipliers
Direct Deck
Roof Tile'
A(ft) -
W Qbf)
I (ft)
.
w (fly
Batten
3":12"'
4"i12"
5':12"'
6":12"
>712"
Application
Bermuda
9.7
1.33
0.833
0.189
6.53
6.43
6.29
6.14
5.97
Plantation
11.6
1.375
1.08
0.267
6.85
6.75
6.61
6.44
6.26
Saxony
10.9
1.417
1.08
0.291
-
6.61
6.48
6.31
6.13
900
Estate "S'
10.0
1.375
1.08
0.267
5.91
5.82
5.70
5.56
5.40
Villa 900
10.9
1.42
1.08
0.291
-
6.56
6.42
6.26
6.08
Barcelona
115
1.417
1.08
0.286
6.19
6.19
6.06
5.92
5.76
900
Spanish
8.95
1.417
0.8125
0.215
5.30
5.21
5.09
4.96
4.82
"S" Nueva
BOR18003 Ft28328 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener
Nlr (ft-lbf)
Roof Tile
Direct Deck
Direct Deck
Type
- Count
Size -
-Shank
-Clip - ,
-(min.15/32'
-(minA9/32"---Battens.
..plywood).
plywood)
Nail
2
10d
Ring
N/A
30.9
38.1
17.2
Nail
1
10d
Smooth
N/A
7.3
9.8
4.9
or Screw
Nail
2
10d
Smooth
N/A
14.0
18.8
7.4
or Screw
Screw
1
#8
N/A
N/A
30.8
30.8
18.2
Bermuda,
Screw
2
#8
N/A
N/A
51.7
51.7
24.4
Plantation or
Saxony 900
Nail
1
10d
Smooth
Field
24.3
24.3
24.2
or Screw
Nail
1
10d
Smooth
Eave
19.0
19.0
22.1
or Screw
Nail
2
10d
Smooth
Field
35.5
35.5
34.8
or Screw
Nail
2
10d
Smooth
Eave
31.9
31.9
32.2
or Screw
Nail'
2
10d
Ring
N/A
50.3
65.5
48.3
Nail
2
10d
Ring
N/A
27.8
37.4
28.8
Nail
1
10d
Smooth
N/A
8.8
11.8
4.1
or Screw
Nail
2
10d
Smooth
N/A
16.4
21.9
7.1
or Screw
Screw
1
#8
N/A
N/A
25.8
25.8
22.9
Estate "S',
Villa 900
Screw
2
#8
N/A
N/A
47.1
47.1
49.1
Nail
1
10d
Smooth
Field
24.3
24.3
24.2
or Screw
Nail
1
10d
Smooth
Eave
19.0
19.0
22.1
or Screw
Nail
2
10d
Smooth
Field
35.5
35.5
34.8
or Screw
Nail
2
10d
Smooth
Eave
31.9
31.9
32.2
or Screw
Estate "S"
Nail'
2
10d
Ring
N/A
43.0
67.5
50.9
i
Continued on following page
BOR18003 FL28328 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener
K (8-lbf)
Roof Tile
Direct Deck
Direct Deck
Type- -
Count `
Size
Shank-
Clip- -
(min. 15132"
-(min.-19/32
-Battens--
plywood)
plywood)
Nail
2
10d
Ring
N/A
28.6
41.2
19.4
Nail
1
10d
Smooth
N/A
5.1
6.8
2.8
or Screw
Nail
2
10d
Smooth
N/A
6.9
9.2
7.3
or Screw
Screw
1
#8
WA
N/A
20.7
20.7
18.1
Barcelona 900,
Screw
2
#8
WA
N/A
43.2
43.2
29.8
Galena3 or
Spanish "S"
Smooth
Nuevo
Nail
1
10d
or Screw
.Field
23.1
23.1
19.0
Nail
1
10d
Smooth
Eave
29.3
29.3
24.0
or Screw
Nail
2
10d
Smooth
Field
27.6
27.6
38.6
or Screw
Nail
2
10d
Smooth
Eave
38.1
38.1
41.8
or Screw
Nail'
2
10d
Ring
WA
33.1
48.1
45.2
Notes: 1) Not for Saxony 900, Villa 900 or Barcelona 900. Installation with a 4" the headlap and fasteners are located a min. 2-1/2"
from head of tile.
2) When using only one fastener, use the hole that is approximately 4-314" away from interlocking edge.
3) Direct Deck applications only.
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Roof Tile
Adhesive
Product Approval'
Paddy
Count
Average Paddy
Weight (grams) -
(ft-Ibf)
Dow Chemical TILE BOND""
NOA 16-0222.01
2
13.9
31.3
Bermuda,
Planation and
Saxony 900
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
31.3
1
24
40.4
1
45
118.9
Saxony 900
DAP Foam Inc. Touch N' Seak@
Storm Boncl 2 Two -Component
'
NOA 17-0829.12
2
8
59.0
1
24
455
1
45
93
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
N/A
WA
43.9
Dow Chemical TILE BONDTM
NOA 16-0222.01
2
11.4
26.1
Estate "S" or
Villa 900
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
26.1
1
24
45.5
1
54
88.61
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
N/A
N/A
20.6
Villa 900
DAP Foam Inc. Touch N' Seal®
Storm Boncl " 2 Two -Component
NOA 17-0829.12
2
8
55
1
30
40
1
60
70
B6R18003 FL28328 Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Concrete Roof Tiles
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Roof Tile
Adhesive
Product Approval'
Paddy
Count
Average Paddy
Weigh (grams)
Mf(ft-Ibf)
Dow Chemical TILE BOND'^"
NOA 16-0222.01
2
10.7
29.3
Barcelona 900,
Galena Spanish
"S" or Spanish
"S" Nuevo
ICP Adhesives Polyset AH-160
NOA 17-0322.03
2
8
29.3
1
24
38.7
1
63
66.5
Premix Marbletite, Inc. TILE-TITE
NOA 17-1016.07
N/A
N/A
24.5
Barcelona 900
DAP Foam Inc. Touch N' Seal®
Storm BondTM 2 Two -Component
NOA 17-0829.12
2
8
66.0
1
30
63
1
60
82
Notes: 1) See manufacturer's product approval for installation requirements.
LABELING
1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows:
Manufactured in lake Wales, FL
Manufactured in Okeechobee, FL
OR
ENTEGRA
B61R18003 FL28328 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
BORAL ROOFING LLC
Concrete Roof Tiles
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published
application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120.
3) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61020-3.
4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below).
so
:::• 5 50
:• WEATHERING REGIONS
0
NEGLIGIBLE WEATHERING
MODERATE WEATHERING
3i:SEVERE
WEATHERING
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building
Code, a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R.
.
�\cENS*-- �.
No 74021
* /f 2018.10.15
9 STATE OF : 19:51:52
00%tID
SS��NA„ �% Zachary
R.Priest,
P.E. Florida Registration No. 4021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor Will acquire, a financial interest in any other entity involved in the approval process of the
product.
BOR18003
END OF REPORT
FL28328
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
FILE COPY
TPJNITYI ERD
EVALUATION REPORT
t q%-dLW
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COTy
B®CC `I(�' �l-
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
East Coast Metals, Inc. RECEIVED Evaluation Report E10240.08.08-R4
2301 West 8 Lane FL5374-R4
Hialeah, FL 33010 MAY 15 ?019 Date of Issuance:09/03/2008
Revision 4: 03/17/2015
SCOPE: ST. Lucie County, Permitting
This Evaluation Report is issued u - !an t e applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted herein.
DESCRIPFION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INsPEcnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by. -
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
Thefaeti Mmalappeatingv au r¢ed by Robert Nieminen,
P.E on03. Sig d, Tusdoesmpierveasaneleettonialhsigted
dacumeM. Signed, sealed hardmpks hoes beenttansmitted to the
Ptod App IAdmiMs4atoratdtothetamed AeM
CERTIFICATION OF INDEPENDENCE:
1. Trinity) ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�1 I KINI"jY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSAJTRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118,119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-1
02/27/2015
ERD (TST6049)
Static Uplift Resistance
ECM-SC6795.12.14-2
02/27/2015
Florida TEC (TST7393)
TAS 101
510-628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-004-02-01
06/13/2008
PRI(TST5878)
TAS 101
ECM-005-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-006-02-01
06/13/2008
PRI (TS75878)
TAS 101
ECM-007-02-01
06/13/2008
PRI (TSi5878)
TAS 101
ECM-008-02-01
06/13/2008
Florida Building Code
Attachment Requirements
FRSA/TRI April 2012 (04-12)
04/2012
Florida Building Code -HVHZ
Attachment Requirements
RAS 118, M and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing(QUA1844)
Quality Control
Participation Letter
Exp. 12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof the adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/84nch)
heights with 1.5-inch (± 1/16-inch) deck -flanges.
Exterior Research and Design, LLC Evaluation Report E10240.08.08-R4
CertlikuteoJAxMonzotlon rr9503 FI5374-R4
Revision 4: 03/27/2015
Page 2 of 7
�l TRINITY I ERD
4.2 Tilm Lock Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 3.5, 4, 5 or 6-inch L+ 3/8-inch) heights
with 1.5-inch (± 1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof the adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
L 3/8") length by 3, 3.5, 4, 5 or 6-inch L 3/8-inch) heights
with 1.5-inch (± 1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min. 0.019 ±0.002-inch, ASTM A653 (G-90), min. 33 KSI.
➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI.
➢ Aluminum: Min. 0.032±0.002-inch, ASTM 13209, 3003-H14, min. 21 KSI.
➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
S. WiTATioNs:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically forthat purpose.
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-114
Certificate Of AU1*arhotioe09503 FL5374-114
Revision 4:03/17/2015
Page 3 of 7
�RINITY ERD
5.2 FOR HVHZJURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lack are prescriptive by RAS 118, 119 and
120, and the data in Tables SA and 18 is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Fr),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturers published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable. performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE IA: PERFORMANCEL virrATIONS- HVHZ, INDEPENDENT PADDY PLACEMENT -
f2 TO MARGIN OFSAFETYALAFAOYAPPUEOf
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
Mr(ft-lbf)
F'(Ibfj
Hip & Ridge
galvanized
clayor
3M"' 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume",
clayor
3M"'2-Component Foam
Independent
171
359
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®,
clayor
3M" 2-Component Foam
Independent
177
165
aluminum or stainless steel
I concrete
Roof Tile Adhesive AH-160
TABLE IB: PERFORMANCE LImrranoxs-HVHZ, INTERDEPENDENT PADDY PLACEMENT
_ (4 TO I MARGIN OFSAFETYAIRFAOYAPPLIED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
M,(ft-Ibf)
F'(Ibf)
Trim lock or Trim
galvanized, Galvalume`,
clayor
3M"'2-Component Foam
Lock Plus
aluminum or stainless steel
Concrete
Roof Tile Adhesive AH-160
Interdependent
95
88
Trim Lock
galvanized, Galvalume®,
clayor
3M"' Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clayor
3M"' Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalume•,
clay or
3M"' Foam Roof Tile
Interdependent
90
84
aluminum or stainless steel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalume• or
clayor
TILE BOND" Roof Tile
Interdependent
123
117
stainless steel
Concrete
Adhesive
Trim Lock
aluminum
clayor
TILE BOND" Roof Tile
Interdependent
79
73
concrete
Adhesive
Trim Lock Plus
galvanized, Galvalume°,
clayor
TILE BOND'" Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
Trim lack
galvanized, Galvalume° or
clay or
Touch'n Seal StormBond
Interdependent
146
139
stainless steel
Concrete
Roof Tile Adhesive
Trim Lock
Aluminum
clayor
Touch'n Seal Storm Bond
Interdependent
58
54
concrete
RoofTile Adhesive
Trim Lock Plus
galvanized, Galvalume®,
clayor
Touch'n Seal StonnBond
Interdependent
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
fevtifimte OfAuMoazotfon A9503 FL5374-R4
Revision 4: 03/17/2015
Page 4 of 7
Cam! I KINITi ERD
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table SA of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the the
adhesive manufacturers published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE 2A- PERFORMANCE UMIrAtiONS—NON-HVHZ, INDEPENDENT PADDY PLACEMENT
(2TO3MARG1NOF&4FETYAMEADYAPPDED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Hip & Ridge
galvanized
or
3M"' 2-Component Foam Roof
independent
169
Channel Metal
concrete
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, GalraiumeO, aluminum or
day or
3M"' 2-Component Foam Roof
independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume•, aluminum or
clay or
3M"' 2-Component Foam Roof
Independent
178
stainless steel
concrete
Tile Adhesive AH-160
TABLE2B: PERFORMANCE UMRATIONS—NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT
(4 To MARGIN OFSAFETYAIHEADYAPPUED)
1.
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(PST)
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume®, aluminum or
day or
3M- 2-Component Foam Roof
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
Interdependent
98
Trim Lock
galvanized, Galvalume®or stainless
clay or
3M"' Foam Roof Tile Adhesive
Interdependent
310
steel
concrete
RTA-1
Trim Lock
aluminum
day or
3M— Foam RoofTkte Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalumeo, aluminum or
clay or
3M" Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume• or stainless
day or
TILE BOND"' Roof Tile Adhesive
Interdependent
152
steel
Concrete
Trim Lock
aluminum
dayor
TILE BOND^' Roof Tile Adhesive
Interdependent
82
Concrete
Trim Lock Plus
galvanized, Galvalume®, aluminum or
dayor
TILE BOND"' Roof Tile Adhesive
Interdependent
82
stainlesssteel
Concrete
Trim Lock
galvanized, Galvalume®orstainless
dayor
Touch'n Seal StormBond Roof
Interdependent
148
steel
concrete
Tile Adhesive
Trim Lock
Aluminum
clay or
Touch'n Seal StormBond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Pius
galvanized, Galvalume®, aluminum or
clay or
Touch'n Seal Stormllond Roof
Interdependent
61
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
Cernflone of Authorization#9503 FL5374-R4
Revision 4:03/17/2015
Page 5 of 7
\.I I PJNITY ERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHL
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x SY.-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject the adhesive.
Exterior Research and Design, LLC Evaluation Report E30240.08.0840
Certificate ojAurhodm0on p9503 FL5374-114
Revision 4: 03/17/2015
Page 6 of 7
�I I RINIlY J ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTRY:
Architectural Testing, Inc.—QUA1844; (717) 764-7700
- END OF EVALUATION REPORT -
Exterior Research and Design, L1G Evaluation Report E30240.08.0&R4
Cerdfiane OfAuthawatlon095a3 FL5374-R4
Revision 4: 03/17/2015
Page 7 of 7