Loading...
HomeMy WebLinkAboutEVALUATION REPORTTECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: Manufacturing Plants: Quality Assurance: Certificate of Authorization No. 29824 SCANNED St. Lucie County 17520 Edinburgh Dr Tampa, FL33647 (813)480-3421 FLORIDA BUILDING CODE GP EDMON BORAL ROOFING LLC T alss ct 1018 75751rvine Center Drive RECEIVED 1 L P Irvine, CA 92618 (800) 669-8453 MAY 15 2019 Lake Wales, FL ST. Lucie County, Permitting Okeechobee, FL REVIEWED FOR PRI Construction Materials Technologies (QUA91 10) CODE COMPLIANCE SCOPE ST• LUCIE COI Category: Roofing Subcategory: Roofing Tiles Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3 Properties: Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift Resistance REFERENCES ED& Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0130.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0426.01-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.02-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.03-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0615.04-11 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.02-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.03-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0617.04-16 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0623.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT0624.04-14 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (rST3782) RT0624.05-14 , TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT1210.02-15 TAS 112 1995 ASTM C 1492 2003(2009) American Test Lab of South Florida Inc (TST3782) RT1210.03-15 TAS 112 1995 ASTM C 1492 2003(2009) Miami -Dade BCCO (CER1592) 14-0408.06 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 14-0416.12 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 15-0721.04 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 16-0112.07 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 16-0112.08 FBC (HVHZ) 2017 MiamFDade SCCO (CER1592) 18-0509.15 FBC (HVHZ) 2017 MiamFDade BCCO (CER1592) 18-0509.16 FBC (HVHZ) 2017 Miami -Dade BCCO (CER1592) 18-0509.17 FBC (HVHZ) 2017 Tile Roof Institute Membership Confirmation TAS 100 1995 TAS 101 1995 TAS 102 8 102(A) 1995 BOR18003 FL28328 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Bermuda (Okeechobee) BORAL ROOFING LLC Concrete Roof Tiles Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, dass III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16" x 10" BOR18003 j 16' r Figure 1. Bermuda FL28328 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20J. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. &,REEK BORAL ROOFINGLLC Concretee RoofRoof Tiles TECHNICAL SERVICES, LLC Plantation (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16-1/2" x 13" Figure 2. Plantation Saxony 900 Slate, Shake and Split Shake (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 3a, flat profile, interlocking, class III concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17" x 13" x 1-5/32" (Slate) or 1-9/32" (Shake and Split Shake) SAIL HOLES "''DERLOCK Figure 3. Saxony 900 Slate --2-(51ae) COVERLOCK BOR18003 FL28328 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC N—AM HOLES \4n HOLES F BOR18003 c/ Figure 4. Saxony 900 Shake y � Figure S. Saxony 900 Split Shake FL28328 BORAL ROOFING LLC Concrete Roof Tiles I-9T-(Shake) T Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. REEK BORAL ROOFING LLC Concrete Roof Tiles TECHNICAL SERVICES, LLC Estate "S" (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 1 b, low profile, interlocking, class III concrete roof file Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 16-1 /2" x 13" Nail Holes Figure 6. Estate Villa 900 (Lake Wales) Profile/Description: ASTM C 1492, TAS 112 Type 1b, low profile, interlocking, class III concrete roof the Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 17.0" x 13" x 2-1/8" 1" BOR18003 �T Figure 7. Villa 900 21/8" i 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Barcelona 900 (Lake Wales) BORAL ROOFING LLC Concrete Roof Tiles ProfileMescription: ASTM C 1492, TAS 112 Type 1a, high profile, interlocking, class III, 'S' shaped concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions: 1 T x 13" x 3-5/8" OVERLOCK 3 5/8' 17 \- f 13• UNDERLOCK -� Figure S. Barcelona 900 Galena Spanish "S" (Okeechobee) Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class Ill 'S' shaped concrete roof the Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications Dimensions: 17" x 10" x 2.7" Fastener Holes 17" 10" Figure 9. Galena Spanish "S" BOR18003 FL28328 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Spanish "S" Nuevo (Lake Wales) BORAL ROOFING LLC Concrete Roof Tiles Profile/Description: ASTM C 1492, TAS 112 Type 2a, high profile, interlocking, class III 'S' shaped concrete roof tile Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications Dimensions- 17" x 9-3/4" x 2-27132" Fastener APPLicAnoN METHOD Holes I 17" 9-3/4" Figure 10. Spanish "S" Nuevo Installation Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSA/TRI Florida High find Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as applicable. Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min.19/32 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. Underlayment: Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment shall be installed as described in RAS 118, RAS 119, or RAS 120, as applicable. BOR18003 FL28328 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles Data for Attachment Calculations for Direct to Deck, Applications Nominal Weight QM and- Aerodynamic Restoring Moments due to Gravity - Nlo (8-Ibf) Dimensions (I x w) Multipliers Direct Deck Roof Tife A (fta) -- 1N (Ibf) I (ft) w (ft) - Direct Deck- -3°:12" 4':12' -6"A2 6":12" >7":12" Application - Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35 Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04 Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95 Estate "r 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14 Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95 Barcelona 115 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42 900 Galena 8.5 1.42 0.833 0.235 6.13 6.03 5.89 1 5.74 5.57 Spanish "S" Spanish "S" 8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39 Nuevo Data for Attachment Calculations for Batten Applications Nominal Weight QM and Aerodynamic Restoring Moments due to Gravity -,Mo (ft-lbf) Dimensions Q x w); Multipliers Direct Deck Roof Tile' A(ft) - W Qbf) I (ft) . w (fly Batten 3":12"' 4"i12" 5':12"' 6":12" >712" Application Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97 Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26 Saxony 10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13 900 Estate "S' 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40 Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08 Barcelona 115 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76 900 Spanish 8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82 "S" Nueva BOR18003 Ft28328 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications Tile Fastener Nlr (ft-lbf) Roof Tile Direct Deck Direct Deck Type - Count Size - -Shank -Clip - , -(min.15/32' -(minA9/32"---Battens. ..plywood). plywood) Nail 2 10d Ring N/A 30.9 38.1 17.2 Nail 1 10d Smooth N/A 7.3 9.8 4.9 or Screw Nail 2 10d Smooth N/A 14.0 18.8 7.4 or Screw Screw 1 #8 N/A N/A 30.8 30.8 18.2 Bermuda, Screw 2 #8 N/A N/A 51.7 51.7 24.4 Plantation or Saxony 900 Nail 1 10d Smooth Field 24.3 24.3 24.2 or Screw Nail 1 10d Smooth Eave 19.0 19.0 22.1 or Screw Nail 2 10d Smooth Field 35.5 35.5 34.8 or Screw Nail 2 10d Smooth Eave 31.9 31.9 32.2 or Screw Nail' 2 10d Ring N/A 50.3 65.5 48.3 Nail 2 10d Ring N/A 27.8 37.4 28.8 Nail 1 10d Smooth N/A 8.8 11.8 4.1 or Screw Nail 2 10d Smooth N/A 16.4 21.9 7.1 or Screw Screw 1 #8 N/A N/A 25.8 25.8 22.9 Estate "S', Villa 900 Screw 2 #8 N/A N/A 47.1 47.1 49.1 Nail 1 10d Smooth Field 24.3 24.3 24.2 or Screw Nail 1 10d Smooth Eave 19.0 19.0 22.1 or Screw Nail 2 10d Smooth Field 35.5 35.5 34.8 or Screw Nail 2 10d Smooth Eave 31.9 31.9 32.2 or Screw Estate "S" Nail' 2 10d Ring N/A 43.0 67.5 50.9 i Continued on following page BOR18003 FL28328 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles Attachment Resistance Expressed as a Moment for Mechanically Fastened Applications Tile Fastener K (8-lbf) Roof Tile Direct Deck Direct Deck Type- - Count ` Size Shank- Clip- - (min. 15132" -(min.-19/32 -Battens-- plywood) plywood) Nail 2 10d Ring N/A 28.6 41.2 19.4 Nail 1 10d Smooth N/A 5.1 6.8 2.8 or Screw Nail 2 10d Smooth N/A 6.9 9.2 7.3 or Screw Screw 1 #8 WA N/A 20.7 20.7 18.1 Barcelona 900, Screw 2 #8 WA N/A 43.2 43.2 29.8 Galena3 or Spanish "S" Smooth Nuevo Nail 1 10d or Screw .Field 23.1 23.1 19.0 Nail 1 10d Smooth Eave 29.3 29.3 24.0 or Screw Nail 2 10d Smooth Field 27.6 27.6 38.6 or Screw Nail 2 10d Smooth Eave 38.1 38.1 41.8 or Screw Nail' 2 10d Ring WA 33.1 48.1 45.2 Notes: 1) Not for Saxony 900, Villa 900 or Barcelona 900. Installation with a 4" the headlap and fasteners are located a min. 2-1/2" from head of tile. 2) When using only one fastener, use the hole that is approximately 4-314" away from interlocking edge. 3) Direct Deck applications only. Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set Roof Tile Adhesive Product Approval' Paddy Count Average Paddy Weight (grams) - (ft-Ibf) Dow Chemical TILE BOND"" NOA 16-0222.01 2 13.9 31.3 Bermuda, Planation and Saxony 900 ICP Adhesives Polyset AH-160 NOA 17-0322.03 2 8 31.3 1 24 40.4 1 45 118.9 Saxony 900 DAP Foam Inc. Touch N' Seak@ Storm Boncl 2 Two -Component ' NOA 17-0829.12 2 8 59.0 1 24 455 1 45 93 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A WA 43.9 Dow Chemical TILE BONDTM NOA 16-0222.01 2 11.4 26.1 Estate "S" or Villa 900 ICP Adhesives Polyset AH-160 NOA 17-0322.03 2 8 26.1 1 24 45.5 1 54 88.61 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 20.6 Villa 900 DAP Foam Inc. Touch N' Seal® Storm Boncl " 2 Two -Component NOA 17-0829.12 2 8 55 1 30 40 1 60 70 B6R18003 FL28328 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC BORAL ROOFING LLC Concrete Roof Tiles Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set Roof Tile Adhesive Product Approval' Paddy Count Average Paddy Weigh (grams) Mf(ft-Ibf) Dow Chemical TILE BOND'^" NOA 16-0222.01 2 10.7 29.3 Barcelona 900, Galena Spanish "S" or Spanish "S" Nuevo ICP Adhesives Polyset AH-160 NOA 17-0322.03 2 8 29.3 1 24 38.7 1 63 66.5 Premix Marbletite, Inc. TILE-TITE NOA 17-1016.07 N/A N/A 24.5 Barcelona 900 DAP Foam Inc. Touch N' Seal® Storm BondTM 2 Two -Component NOA 17-0829.12 2 8 66.0 1 30 63 1 60 82 Notes: 1) See manufacturer's product approval for installation requirements. LABELING 1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows: Manufactured in lake Wales, FL Manufactured in Okeechobee, FL OR ENTEGRA B61R18003 FL28328 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC LIMITATIONS BORAL ROOFING LLC Concrete Roof Tiles 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120. 3) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61020-3. 4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A. 5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of 50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below). so :::• 5 50 :• WEATHERING REGIONS 0 NEGLIGIBLE WEATHERING MODERATE WEATHERING 3i:SEVERE WEATHERING COMPLIANCE STATEMENT The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building Code, a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. . �\cENS*-- �. No 74021 * /f 2018.10.15 9 STATE OF : 19:51:52 00%tID SS��NA„ �% Zachary R.Priest, P.E. Florida Registration No. 4021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor Will acquire, a financial interest in any other entity involved in the approval process of the product. BOR18003 END OF REPORT FL28328 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. FILE COPY TPJNITYI ERD EVALUATION REPORT t q%-dLW REVIEWED FOR CODE COMPLIANCE ST. LUCIE COTy B®CC `I(�' �l- EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 East Coast Metals, Inc. RECEIVED Evaluation Report E10240.08.08-R4 2301 West 8 Lane FL5374-R4 Hialeah, FL 33010 MAY 15 ?019 Date of Issuance:09/03/2008 Revision 4: 03/17/2015 SCOPE: ST. Lucie County, Permitting This Evaluation Report is issued u - !an t e applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted herein. DESCRIPFION: East Coast Metals Channel Metals LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INsPEcnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by. - Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 Thefaeti Mmalappeatingv au r¢ed by Robert Nieminen, P.E on03. Sig d, Tusdoesmpierveasaneleettonialhsigted dacumeM. Signed, sealed hardmpks hoes beenttansmitted to the Ptod App IAdmiMs4atoratdtothetamed AeM CERTIFICATION OF INDEPENDENCE: 1. Trinity) ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �1 I KINI"jY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1507.3.7 Installation, non-HVHZ FRSAJTRI April 2012 (04-12) 2012 1518.8.1 Installation, HVHZ RAS 118,119 & 120 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015 ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015 Florida TEC (TST7393) TAS 101 510-628R 10/27/2010 PRI (TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI (TST5878) TAS 101 ECM-003-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-004-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-006-02-01 06/13/2008 PRI (TS75878) TAS 101 ECM-007-02-01 06/13/2008 PRI (TSi5878) TAS 101 ECM-008-02-01 06/13/2008 Florida Building Code Attachment Requirements FRSA/TRI April 2012 (04-12) 04/2012 Florida Building Code -HVHZ Attachment Requirements RAS 118, M and 120 1995 East Coast Metals Metal Quality Mill Certifications Various Architectural Testing(QUA1844) Quality Control Participation Letter Exp. 12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof the adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L 3/84nch) heights with 1.5-inch (± 1/16-inch) deck -flanges. Exterior Research and Design, LLC Evaluation Report E10240.08.08-R4 CertlikuteoJAxMonzotlon rr9503 FI5374-R4 Revision 4: 03/27/2015 Page 2 of 7 �l TRINITY I ERD 4.2 Tilm Lock Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch L+ 3/8-inch) heights with 1.5-inch (± 1/16-inch) deck -flanges. 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof the adhesive, which flows -through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch L 3/8") length by 3, 3.5, 4, 5 or 6-inch L 3/8-inch) heights with 1.5-inch (± 1/16-inch) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: ➢ Galvanized Steel: Min. 0.019 ±0.002-inch, ASTM A653 (G-90), min. 33 KSI. ➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI. ➢ Aluminum: Min. 0.032±0.002-inch, ASTM 13209, 3003-H14, min. 21 KSI. ➢ Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI. S. WiTATioNs: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat purpose. Exterior Research and Design, LLC. Evaluation Report E10240.08.08-114 Certificate Of AU1*arhotioe09503 FL5374-114 Revision 4:03/17/2015 Page 3 of 7 �RINITY ERD 5.2 FOR HVHZJURISDICTIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lack are prescriptive by RAS 118, 119 and 120, and the data in Tables SA and 18 is supplemental to these prescriptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Fr), as determined in accordance with RAS 127, not greater than the following values. Refer to the tile adhesive manufacturers published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable. performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE IA: PERFORMANCEL virrATIONS- HVHZ, INDEPENDENT PADDY PLACEMENT - f2 TO MARGIN OFSAFETYALAFAOYAPPUEOf Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based Mr(ft-lbf) F'(Ibfj Hip & Ridge galvanized clayor 3M"' 2-Component Foam Independent 127 169 Channel Metal concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalume", clayor 3M"'2-Component Foam Independent 171 359 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume®, clayor 3M" 2-Component Foam Independent 177 165 aluminum or stainless steel I concrete Roof Tile Adhesive AH-160 TABLE IB: PERFORMANCE LImrranoxs-HVHZ, INTERDEPENDENT PADDY PLACEMENT _ (4 TO I MARGIN OFSAFETYAIRFAOYAPPLIED) Hip/Ridge Metal Tile Adhesive Allowable Performance Moment Based Uplift Based Design Metal Type Type Placement M,(ft-Ibf) F'(Ibf) Trim lock or Trim galvanized, Galvalume`, clayor 3M"'2-Component Foam Lock Plus aluminum or stainless steel Concrete Roof Tile Adhesive AH-160 Interdependent 95 88 Trim Lock galvanized, Galvalume®, clayor 3M"' Roof Tile Adhesive Interdependent 99 94 stainless steel concrete RTA-1 Trim Lock aluminum clayor 3M"' Foam Roof Tile Interdependent 90 84 concrete Adhesive RTA-1 Trim Lock Plus galvanized, Galvalume•, clay or 3M"' Foam Roof Tile Interdependent 90 84 aluminum or stainless steel concrete Adhesive RTA-1 Trim Lock galvanized, Galvalume• or clayor TILE BOND" Roof Tile Interdependent 123 117 stainless steel Concrete Adhesive Trim Lock aluminum clayor TILE BOND" Roof Tile Interdependent 79 73 concrete Adhesive Trim Lock Plus galvanized, Galvalume°, clayor TILE BOND'" Roof Tile Interdependent 79 73 aluminum or stainless steel concrete Adhesive Trim lack galvanized, Galvalume° or clay or Touch'n Seal StormBond Interdependent 146 139 stainless steel Concrete Roof Tile Adhesive Trim Lock Aluminum clayor Touch'n Seal Storm Bond Interdependent 58 54 concrete RoofTile Adhesive Trim Lock Plus galvanized, Galvalume®, clayor Touch'n Seal StonnBond Interdependent 58 54 aluminum or stainless steel concrete Roof Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 fevtifimte OfAuMoazotfon A9503 FL5374-R4 Revision 4: 03/17/2015 Page 4 of 7 Cam! I KINITi ERD 5.3 FOR NON-HVHZ JURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table SA of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the the adhesive manufacturers published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE 2A- PERFORMANCE UMIrAtiONS—NON-HVHZ, INDEPENDENT PADDY PLACEMENT (2TO3MARG1NOF&4FETYAMEADYAPPDED) Hip/Ridge Metal Tile Adhesive Allowable Uplift (Psf) Design Metal Type Type Placement Hip & Ridge galvanized or 3M"' 2-Component Foam Roof independent 169 Channel Metal concrete concrete Tile Adhesive AH-160 Trim Lock galvanized, GalraiumeO, aluminum or day or 3M"' 2-Component Foam Roof independent 173 stainless steel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume•, aluminum or clay or 3M"' 2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 TABLE2B: PERFORMANCE UMRATIONS—NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT (4 To MARGIN OFSAFETYAIHEADYAPPUED) 1. Hip/Ridge Metal Tile Adhesive Allowable Uplift (PST) Design Metal Type Type Placement Trim Lock or Trim galvanized, Galvalume®, aluminum or day or 3M- 2-Component Foam Roof Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98 Trim Lock galvanized, Galvalume®or stainless clay or 3M"' Foam Roof Tile Adhesive Interdependent 310 steel concrete RTA-1 Trim Lock aluminum day or 3M— Foam RoofTkte Adhesive Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized, Galvalumeo, aluminum or clay or 3M" Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized, Galvalume• or stainless day or TILE BOND"' Roof Tile Adhesive Interdependent 152 steel Concrete Trim Lock aluminum dayor TILE BOND^' Roof Tile Adhesive Interdependent 82 Concrete Trim Lock Plus galvanized, Galvalume®, aluminum or dayor TILE BOND"' Roof Tile Adhesive Interdependent 82 stainlesssteel Concrete Trim Lock galvanized, Galvalume®orstainless dayor Touch'n Seal StormBond Roof Interdependent 148 steel concrete Tile Adhesive Trim Lock Aluminum clay or Touch'n Seal StormBond Roof Interdependent 61 concrete Tile Adhesive Trim Lock Pius galvanized, Galvalume®, aluminum or clay or Touch'n Seal Stormllond Roof Interdependent 61 stainless steel concrete Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 Cernflone of Authorization#9503 FL5374-R4 Revision 4:03/17/2015 Page 5 of 7 \.I I PJNITY ERD 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHL 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x SY.-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation 6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved use of the subject the adhesive. Exterior Research and Design, LLC Evaluation Report E30240.08.0840 Certificate ojAurhodm0on p9503 FL5374-114 Revision 4: 03/17/2015 Page 6 of 7 �I I RINIlY J ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal Installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTRY: Architectural Testing, Inc.—QUA1844; (717) 764-7700 - END OF EVALUATION REPORT - Exterior Research and Design, L1G Evaluation Report E30240.08.0&R4 Cerdfiane OfAuthawatlon095a3 FL5374-R4 Revision 4: 03/17/2015 Page 7 of 7