NOTICE OF ACCEPTANCE I
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
Boral Roofing LLC. I SCiAlvlurl)
7575Irvine Center Drive, Suite 100 MAY 1 5 20i9 By
St LIICIF trfty
Irvine, CA 92618
ST. LUCK County. PermiMinn
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: BORAL TileSeal
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This new NOA consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigers.
NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
ROOFING COMPONENT APPROVAL
Category:
Roofing
Sub -Category:
Underlayment
Material:
SBS
PRODUCTS DESCRIPTION:
Test
Product
Product Dimensions Specification
Description
BORAL TileSeal 36" x 36'
rolls TAS 103
SBS self -adhering asphalt sheet material with a
36" x 72'
rolls ASTM D1970
white glass re -enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
Boral Citadel Plus 36" x 72'
rolls ASTM D1970
SBS self -adhering asphalt sheet material with a
poly film -facer; for use as a mid -ply underlayment
in sloped roof assemblies.
MANUFACTURIGN LOCATION:
1. Brentwood, NH.
2. Houston, TX.
EVIDENCE SUBMTTTED:
Test Agency
Test Identifier
Test Name/Report Date
PRI Construction Materials
OCF-356-02-04
ASTM D1623 07/25/18
Technologies, LLC.
OCF-356-02-02
TAS 103 07/24/18
OCF-356-02-01
ASTM D1970 07/26/18
OCF-424-02-04
ASTM D1623 07/25/18
OCF-424-02-01
ASTM D1970 07/25/18
OCF424-02-03
TAS 103 07/25/18
Trinity ERD BRLRF-SC 16810.11.17
ASTM D 1876 11/28/17
NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 15/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies ofASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps
and two staggered rows 12" o.c. the field of the roll.
Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval.
(Optional):
Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and
minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All
end laps and laps without black selvage area shall be sealed under lap using an SBS modified
mastic.
Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side
laps. No nails or tin caps shall be exposed.
Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof
Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
MIAMMADE COUNTY NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
LE%nTATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment.
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
S. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing
BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL
TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami -Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment, and sealed using an SBS modified mastic.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below
END OF THIS ACCEPTANCE
NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
/TRI
T`v'VO PLY SYSTEM
General - Two Ply Systems are those methods of ap i e a Base Sheet is mechanically attached or self adhered to
the decking. The Cap Sheet shall be attached by Hot Asphalt, Cold Process, Heat Applied, Self Adhered or Mechanically
Attached. Minimum thickness shall be 40 mil SBS, APP or approved equal.
Base Sheet - The Base Sheet shall be self adhered or
mechanically attached to the deck with nails and tin tags,
round cap nails or other approved fasteners spaced in accor-
dance with the Underlayment Fastening Table I (Page 13
Appendix A). Extend the Base Sheet a minimum of 4" upver-
tid surfaces. Base Sheet side laps shall be a minimum of 6"
and head laps shall be a minimum of 2". Install the Base Sheet
to ensure all valleys are woven past the centerline and
through the succeeding course of underlayment on the inter-
secting deck to prevent a water lap. Ensure that each course
of underlayment is overlapped by the succeeding course at
the intersecting roof plane. Proceed up the roof to the ridge.
Overlap hip and ridges a minimum of 6.
Drip Edge - The Eave and Gable Drip Edge metal shall be
installed over the Base Sheet The metal shall be coated with
compatible primer prior to the Cap Sheet being installed.
The metal shall be fastened 6" on center with. approved fas-
teners. All joints shall be lapped a minimum of 3° and sealed
with compatible flashing cement, beads of sealant or solid
coating at the lap. Continue from eave up the. rake/gable in
the same manner, ensuring water shedding. capabilities of all
metal laps.
Since Raised Fascia and Starter Strips create the same type of
water dam situation,they both require an Anti-Ponding
System to allow water to flow off the roof at the eave. See
Drawing FHW-11.
Cap Sheet - The two-ply underlayment flashing options
determines the Cap Sheet Installation timing. Choose one of
the following and proceed accordingly.
Under the Cap Sheet. See Metal Installation. See
Drawing F14W-02B
• On Top of the Cap Sheet, proceed to the next sec-
tion. See Drawing FHW-02C
Cap Sheet Installation - Side laps shall be a minimum of 6",
head laps shall be a minimum of 3" and back nailed 12" on
center with approved fasteners. When using battens, back
nailing the Cap Sheet is optional. Install Cap Sheet to ensure
all valleys are woven past the centerline and through the suc-
ceeding course of Cap Sheet on the intersecting deck to pre-
vent a water lap. Ensure that each course of Cap Sheet is
overlapped by the succeeding course at the intersecting roof
plane. Over lap all hip and ridges by 6°. On Cap Sheet, cut any
fishmouths and seal with flashing cement and membrane
where applicable. When using Pre -formed Metals without
edge returns, the Cap Sheet should terminate I" from the
water diverter to ensure adhesion to the primed metal.
Cap Sheet Attachment Method - Choose one of the fol-
lowing.
° Not Asphalt - Install the Cap Sheet with an application
rate of 25 pounds per square t 15% mopping of
asphalt The Cap Sheet may come in contact with the
Base Sheer, allowing felt to touch felt.
lc SeH Aa�ver installed Base Sheet, apply one
layer of Self Adhered Underlayment in compliance with
the Self Adhered underlayment manufacturer's recom-
mendation.
Gold process - Install Cap Sheet accordingto underlay-
ment(adhesive manufacturers recommendations. For
Cold Process Systems in windy conditions, it may be
necessary to spot nail Cap Sheet laps at a maximum of
Ton center.
• Heat Applied - Install Cap Sheet per manufacturers
instructions.
Mechanical Attachment - Battens may be used with
this application method. The Cap Sheet shall be back
nailed to the Base Sheet with nails and tin tags, round
cap nails or other approved fasteners to secure the Cap
Sheet until the flattens can be installed. Windy condi-
tions may, require additional securement of the Cap
Sheet at the overlaps.
Valley Intersection - When installing the Cap Sheet at the
valley intersection, choose one of the following installation
methods. Be sure that the underlayment does not create a
gap due to memory of the material.
Full Weave - install underlayment to ensure all valleys
are woven past the centerline and through the succeed-
ing course of underlayment on the intersecting deck to
prevent a water lap. Ensure that each course of under-
layment is overlapped by the succeeding course at the
intersecting roof plane. Proceed up the roof to the
COPYRIGHT 0 FRSAMLE ROOFING INSTITUTE April 2012
If utilizing staples then the battens shall be attached at 12" on
center with staples 7/16" crown, No.16 gauge corrosion
resistant allowing for 3/4" penetration into roof deck or
through the sheathing whichever is less. Staples cannot be
used with adhesive set systems.
Leave 1/2" space between batten ends and between batten
and metal edge returns. Fasteners shall be compatible with
batten material.
Note: Elevated or counter batten systems require FBC
product approval. Contact the roof tile manufacturer for
product approval and installation instructions.
Tile Installation : Stack tile to facilitate installation and min-
imize file movement. See Drawing FHW-19. At the eave clo-
sure all fattener penetrations shall be sealed and installed to
avoid restricting water flow. Choose one of the following
eave closures.
• Metal Eave Closure .Install closure strip along eave.
.mum on center. If metal closure is inclu-
sive of the drip edge, fasten 6" on center. See Drawing
FHW-i I.
Prefabricated Rubber Eave Closure - Install closure
strip along eave. Fasten with minimum three fasteners
per 36" strip. See Drawing FHW-1 I.
• Raised Fascia/Wood Starter Strip - See Drawing
FHW-11.
• Prefabricated concrete or day eave closure -Apply
per manufacturers instructions.
Mortar - Install mortar to elevate eave file on Granular
Surfaced underiaymenes only. Apply mortar along the
eave edge, applying enough mortar to elevate the eave
end of the tile to be on plane with the remaining roof
tile. Point and smooth finishflush to eave line. A.mini-
mum 318" weep hole flush with the roof underlayment
shall beformed at the spacing of not less than one weep
hole per tile.
RI
Flat/Low, Medium and High Profile Tile - Tile shall be
attached to resist the aerodynamic moment as determined
when using the design pressures for the building and the
attachment calculations set forth in the local building code.
Starting at the eave, make certain the tile overhangs the drip
edge uniformly along the first course. The tile shall over-
hang the eave line by atleast3W but not more than 2".
Secure tiles with Nails, Screws. Foam/Adhesive or Mortar.
See Attachment Resistance Values per Tables I & 2 in
Appendix A.
Cut/break tile for proper staggering of tile courses when
using staggered/cross bond method of installation. Set file in
stepped course fashion or in a horizontal and/or vertical fash-
ion when utilizing straight bond method. Lay succeeding
courses of field file in same manner. Cut/break field file to
form straight edge at center of hip/ridge.
Valleys - It is not recommended to install trim tile in the val-
leys. It may be necessary to remove the lugs from the field
the at wells and valley fleshings for proper positioning of cut
field tiles. Choose one of the following.
• Valley metal without Water Diveners. See Drawing
FHW-03.
Closed Valley- Miter file to meet at center of valley. See
Drawing FHW-03.
Open Valley - Chalk a line minimum 2" on both sides of
valley center. Place bed of mortar along outside edge of
chalk lines on Granular Surfaced undedayment'sonly.
Miter file to form straight border and point mortar to
finish. See Drawing FHW-03.
• Valley metal with Water Diverters.
Closed Valley - Miter file to form straight border on
either side of water diverters. See Drawing FHW-03.
Open Valley - Miter file to forth straight border on
either side of the two water diverters. See Drawing
FHW-03.
COPYRIGHT 0 FRSATILE ROOFING INSTITUTE April 2012
HIP AND RIDGE INSTALLATION
General - The following recommendations are only for products approved by the Florida Building Code (FBC) and tested
according to SSTD-I I via third parry independent FBC approved laboratories. They will determine the wind upliift limitations
of the various hip and ridge attachment methods or by installation methods currently recognized in the High Velocity
Hurricane Zone (HVHZ) section of the FBC. There are three basic attachment methodsof the hip and ridge tiles: mechani-
cal attachment, adhesive -set and mortar -set attachment systems. The minimum head lap when installing hip and ridge tiles is
2° unless restricted by product design. Any exposed fasteners should be covered with a IN resistant sealant.
Field Tile Cuts at Hip or Ridge - All cut field tiles adjacent to a hip or ridge shall be attached to the Cap Sheet and/or the
adjacent tile with an approved adhesive, mortar or mechanical fasteners and adhesive.
The following table outlines the different parameters for the hip and ridge attachment options. See Drawing FHW-13.
MilkM
,
✓ 9
B
•
Foam
Mechanical
Metal
Mechanical
or Foam
Foam
Foam
Coating
Mortar
Mortar
Mortar
Plastic
Foam
Foam
Foam
Coatis
Mortar
Mortar
Wood
Fcami
H-Bracket
Straps
Foam
Foam
Coating
Mortar
Mortar
Mechanical
with
Adhesive
Foam
Coating
Flexible
_Dry
Mortar
Mortar
Foam
Mortar
Mortar
Mortar
Mortar
Mortar
Mortar
Hip and Ridge Attachment- Choose one of the following.
• Metal Member - Set member in plastic cement or
compatible sealant. Fasten 6" on center on each side of
the metal flange with minimum I-1/4' ring shank roofing
nails. If mechanical attachment of the member is not used,
install the member with Foam per the manufacturers
instructions.
• Plastic Member - Install the member with Foam per
the manufacturer's instructions.
Wood Member - Fasten 18' on center with four #8
screws per metal strap or H-bracket Each attachment
point shall have two fasteners on each side of the wood
member. The fasteners shall be spaced .evenly on the
metal strap or H-Bracket with the attachment holes
parallel to the hip or ridge. The Straps and H-Brackets
shall be a minimum of 26gauge. All materials must be
compatible with each other. If mechanical attachment of
the wood member is not used, install the member with
Foam per the manufacturer's instructions.
• Mortar - When using Foam or Mortar field the attach -
COPYRIGHT O
ment, Mortar can be used as a structural attachment.
Place a full bed of pre -bagged mortar under the entire
tile. Each tile must be fully embedded into the mortar.
The field tile secured to the underlayment along with
the mortar on each trim tile creates the structural bond.
The entire cavity under the trim tile should be filled with
approved mortar.
Starter Tiles -All starter tiles must be secured at both ends
of the file either with mechanical fasteners, mortar and/or
adhesive.
When the field file is installed with foam or mortar, the
starter tile may be installed with an approved mortar.
If using a structural member choose one of the following.
Metal Member - Place foam under starter tile per
manufacturer's recommendations or secure the head of
the tile with one #8 screw and apply adhesive in the gap
between the structural support and the tile. The member
may need to be cantilevered to provide a base for the
adhesive. The starter file must make contact with the
adhesive. See manufacturer's recommendations.
FRSA/TILE ROOFING INSTITUTE
April 2012
Plastic Member - Place foam understarter tile per
manufacturers recommendations.
Wood Member - Place foam under starter tile per
manufacturers recommendations or drill a hole in the
lower third of the starter file and secure with a mechanical
fastener into the wood member a minimum of I", seal
the head of the fastener with a UV resistant sealant.
Adhesive may be used in lieu of a fastener as long as the
wood member has been cantilevered to provide a base
for the adhesive. The gap between the structural sup-
port and the tile must make contact with the adhesive.
See manufacturer's recommendations.
Miter or point up the hip starter tile to match the intersecting
eaves.
After the Starter Tile - Install the next tile centering over
the structural support and/or the starter tile. Continue in
same manner working from the lowest point toward the
highest point of the roof. At intersecting junctions Q.e. hip/
ridge, ridge/gable, ridge/valley), cut tile to forth a solid fit and
ensure the first and the last hip/ridge tile is securely fastened.
Any exposed fasteners shall be sealed with a UV resistant
sealant. Foam must. come in contact with the bottom of the
tile and structural support member.
Weather Blodd ip and ridge tiles need to have weather
mg. Choose one of the following. See drawing FHW-13
for more details.
Mortar - Pre -bagged or job -site mix is used to weather
block the longitudinal edges of the hip and ridge tiles and
provide aesthetics. A full bed of mortar is placed along
the longitudinal edges of the hip and ridge tile either
during: the application of the hip and ridge tiles or may
be packed in after the hip and ridge tiles are installed and
the adhesive has cured. Install mortar to seal all voids
between the field tile and the hip/ridge tile. Care should
be taken to ensure enough mortar is used. The mortar
should create a wedge to keep the mortar from dislodging
from under the hip/ridge and the field tile junction.
Ensure areas we sealed to prevent water entry. Aker
the mortar is packed into place, then point up mortar to
the desired finish.
Foam- used to weather block the entire cavity of the
• a joining -planes of field tile to the sides of the structural
support This system uses foam as the weather blocking.
There is no mortar placed along the longitudinal edges
of the hip and ridge tile. Foam is placed where the field
tile abuts the structural support. A bead of foam is
placed parallel to the hip and/or ridge and the structural
ONE- - �71
support to rile junction to act as a weather block and is
applied prior to the attachment of the hip and ridge tile.
Install foam to seal all voids between the field tile and
the structural support. Care should be taken to ensure
all areas are sealed with adhesive to prevent water
entry. Apply a polyurethane compatible coating to protect
the foam from UV exposure.
Flexible Self Adhered Membrane - This system can
be used with a wood structural support. The flexible self
adhered membrane is applied in a continuous or step
fashion sealing to both sides of the adjoining field tile a
minimum of 2" prior to the mechanical attachment of
the trim tile to the wood structural support The flexible
flashing may be visible, but should not extend onto the
field tile beyond the outside edges of trim tile.
Rake/Gable - Choose one of the following.
Rake Tile - Cut and install first rake file the exposed
length of first course of field tile with factory finish of
rake tile towards the eave. Fasten rake tilewith a minimum
two I Od nails and/or of sufficient length to penetrate the
framing a minimum of 1 ". Abut each succeeding rake tile
to the nose of the field tile above and maintain a constant:
head lap.
Mortar Finish - Place mortar bed along roof edge.
Point smooth to a straight edge finish.
Wall Abutments - It may be necessary to remove lugs from
the field tile and/or install batten extenders at wall flashing
for proper positioning of cut field tiles. For mechanically
attached tile systems, tiles installed at wall abutment shall be
attached with an adhesive. The adhesive shall be installed to
the underlayment or the tile below/next to the tile being
installed to meet the required uplift. Cut the tile to fit within
V of the base of finished wall. Point -up mortar is optional.
Plumbing. Stacks/Soil Stacks - Choose one of the following.
• Pre -formed Soil Flashing (with returns) - A lead skirt
flashing or flexible flashing with minimum 18" x I S' base
shall be used. This flashing shall be woven in with the tile
coursing. See Drawing FHW-07.
• Standard Flashing - Cut file to fit close to plumbing
stack; fill void with mortar and point to finish.
Coatings - (Optional) Sealer may be applied to exposed
mortar. Color coordinated paint may be applied to metal
flashings.
COPYRIGHT 0 FRSAMLE ROOFING INSTITUTE April 2012
I
Boo -
UNDERLAYMENT APPLICATION - TWO PLY
Self -Adhered
'ne rCr i'IJ3 ]rr tY iws-nt,: ]1T^7C7 cri
Tut, 1�'cla'te cffl'cct'er cl 11 tiE rct.-, i rccbi as
COPYRIGHT m FRSAMLE ROOFING INSTITUTE
FHW-02B
rP �=CUIFEU
rT-
T TAIr¢ n7e
} AI'i. �I`tLLn"
HN t SEELP =CF:
EA,^[.,tL I"` Q.C.
U;'! ii��LE P4lIc4
ECJ=[ IFT-L
L'P.f LU:c C U.L.
, gi- of
u :ry t1:5.
April 2012
7M
EAVE TREATMENT
Eave Closure and Anti-Ponding without Sealant
FHW-11
FAST=n E E= - l-E =P -.0 `
P'E-rk=F..C'--r. F:ie=Ez
PL 110=r Ir0) b- uca] as 31 cl:sj,�. O= 1'E7sl_ 7;,= ;L-:S_P.d
=,Eli 1LE
•U
��. �• �� cl%. 4: ; it=f
1 LCC -
IPP"I T
:PTI_IU,_ : L4c11C
)ryV:i'g3 ert' V' I lip e'•l' %2 9Jn rs?: rfa\.
Jre;: g sYo'.rr dr_i:c Pe r_p6.,3t.0i or of Cl= p-J-; s. .efts ots@ryr'tt odcd '1 •r_�t: axl+ L- i tYcr s:ru� ;r c+. - -i-3s
COPYRIGHT O FRSAMLE ROOFING INSTITUTE April 2012
METAL STRUCTURE HIP AND RIDGE SUPPORT
-!P r:FD F.D:E i,TTA: D
YF'. t--C_E: AP!P "t!' 1."'Hi.S?'c
FHW-14A
1`1_7,11 =E= 7,•VJFVT_RER
U i.:EtcLd il�fJ' J- !P'P.3,=D FLP.
` _
ME-LL =I? i :D F. D;E FRAVE
T_ J11:1 z[VIP3l01. Mill
r-.=,;jP,-g_E ,Dn= �=H]IT 1IIIt
LRi=EFLAAAE1J- VE-5 AS-•.•
bi:d:h: of roJcr ,ca-.z r_lc-+_ :E,.1,.0; '•=
r>..ai be ts-.'. M.>Ji I.m Itir,Ln-ss _
C :cl .::JYi:n_I r•J171 z:o's.
n� :rruioas rre I'f I u;t; ;'ir-rn.rn's?=. n-I:.
COPYRIGHT m FRSAMLE ROOFING INSTITUTE
April 2012
FILE COPY
MIAM4DADE �-'�
- w. REVIRWED FOR
DEPARTMENT OF REGULATORY AND ECO �� �`
BOARD AND CODE ADMINISTRATION DIYISIO T.
p ' 1 /q w'T�E
S 1 . LUCI COV A I
NOTICE OF ACCEPTANCE (NOA) ' Rnr. . tAt
ICP Adhesives and Sealants, Inc.
12505 NW 44m Street
Coral Springs, FL. 33065
11
MAY 15 2019
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Sheet, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
BY
St. Lucie County
.SCOPE: I ST. Lucie County, Permitting
This NOA is being issued under the applicable Hiles and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyset®RTA-1
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it
shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 16-0315.03 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0131.02
x' Expiration Date: 01/03/21
l L . Approval Date: 07/12/18
Page 1 of 8
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves Polyset® RTA-1 as manufactured by ICP Adhesives and Sealants, Inc. as described below in this
Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code,
do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use with approved
flat, low, and high profile roof file systems using Polyset® RTA-l.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
Polyset® RTA-1
N/A TAS 101 Single component polyurethane foam roof tile
adhesive.
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of Polyset® RTA-1 roof tile adhesive.
MANUFACTURING LOCATION:
1. Norton, OH.
PHYSICAL PROPERTIES:
Property
Test
Density
ASTM D 1622
Compressive Strength
ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2842
Water Vapor Permeance
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content
ASTM D 2856
Results
1.71bs./ft.3
8.6 psi Parallel to rise
25 psi
3.2 Lbs./Fe
2.8 perms
-0.5% Volume Change @ 700 C., 2 Weeks
95.3%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
MIAMI•DADE COUNTY
NOA No.: 18-0131.02
Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 2 of 8
EVIDENCE SUBMTPTED:
Test Auencv Test Identifier Test Name/Report
Date
Southwest Research Institute 01-1208-025 ASTM E 108
06/16/98
PRI Construction Materials FOP-009-02-10 Physical Properties
12/14/10
Technologies, Inc. FOP-009-02-01 TAS-101
11/8/10
FOP-009-02-02 TAS-101
11/4/10
FOP-009-02-03 TAS-101
11/8/10
FOP-009-02-04 TAS-101
11/8/10
FOP-009-02-05 TAS-101
11/8/10
Trinity ERD ICP-SC10045.11.17-1 Physical Properties
11/21/17
NEMO Etc. 4-ICP-18-001.05.18-2 TAS 101 / TAS 123
05/15/18
LIlvIITATIONS:
1. Fire classification is not part of this acceptance.
2. Polyset® RTA-I can be used with flat, low, medium and high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of Polyset® RTA-1 roof file adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
f 2)—W
_
F—
MS
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 18-0131.02
MAMFDAD, COUNTY Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 3 of 8
INSTALLATION:
1. Polyset' RTA-1 may be used with any roof tile assembly having a current NOA that lists attachment
resistance values with the use of Polyset® RTA-1.
2. Polyset® RTA-1 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use
of Polyset® RTA-1 shall provide sufficient attachment resistance to meet or exceed the resistance values
determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. Polyset' RTA-1 roof tile adhesive and its components shall be installed in accordance with Roofing
Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and
Maintenance Booklet
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives
and Sealants, Inc.
5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after Polyset' RTA-1
has been dispensed.
6. Polyset' RTA-1 placement shall be in accordance with the Placement Details' herein. Each generic tile
profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile
Profile
Typical Placement
Detail
Weight per paddy (grams)
Flat, Low & High Profile
# 1
11
High Profile 2-Piece Barrel
92
12
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
IiA■' UW
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 18-0131.02
Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 4 of 8
ADHESIVE PLACEMENT DETAILS
PLACEMENT DETAIL # 1
4banyAertc!» Rits
y
J_r /
Lbc4ric3 Of Tlt«
Fvfatn!Ay a• Tie cams-_ L:ne
Enn G-ust Llne
sava cl-wA
91
Sln:sa-I3d.
}•
al'ra OmmuEe Lltie
�az crane
FLAT PROFILE
NOA No.: 18-0131.02
Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 5 of 8
Envn raur" line
Eavn a.a -
PLACEMENT DETAIL # 1 (CONT...)
Lr Prr, s
MEDIUM PROFILE
i?!ui:t.1?aUp
'A
i
NOA No.: 18-0131.02
Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 6 of 8
GSie
{JItT
Ea,e
PLACEMENT DETAIL # 2
Pm CMa
Ftr,G of mo ai
fach Rohe TIC Cv=o Lmo
HIGH PROFILE
P,at1w
NOA No.: 18-0131.02
Mru•oanecounm Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 7 of 8
EnYa
Lb-m
sm
PLACEMENT DETAIL # 2 (CONT...)
Cni{7-i Puddy
&Dell tits wd�(
paeCl iS :l Uj Goa
-
anew nan as:
2•Pictc-camel Pr6e
2-PIECE BARREL PROFILE
END OF THIS ACCEPTANCE
Tom.:».:-Ctruy
by
.v. cion
I-T'P..:dy
}: elje UN:K
,Vl
NOA No.: 18-0131.02
Expiration Date: 01/03/21
Approval Date: 07/12/18
Page 8 of 8