HomeMy WebLinkAboutNOA1 lF A R WED EVI��3OR CODE COMPLIANCE MIMI®,,E ST. LUCIE C 1 Ty DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE I MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy Boral Roofing LLC. I SCiAlvlurl) 7575Irvine Center Drive, Suite 100 MAY 1 5 20i9 By St LIICIF trfty Irvine, CA 92618 ST. LUCK County. PermiMinn SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigers. NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering asphalt sheet material with a 36" x 72' rolls ASTM D1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. Boral Citadel Plus 36" x 72' rolls ASTM D1970 SBS self -adhering asphalt sheet material with a poly film -facer; for use as a mid -ply underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMTTTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials OCF-356-02-04 ASTM D1623 07/25/18 Technologies, LLC. OCF-356-02-02 TAS 103 07/24/18 OCF-356-02-01 ASTM D1970 07/26/18 OCF-424-02-04 ASTM D1623 07/25/18 OCF-424-02-01 ASTM D1970 07/25/18 OCF424-02-03 TAS 103 07/25/18 Trinity ERD BRLRF-SC 16810.11.17 ASTM D 1876 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies ofASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval. (Optional): Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. MIAMMADE COUNTY NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 LE%nTATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. S. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below END OF THIS ACCEPTANCE NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 /TRI T`v'VO PLY SYSTEM General - Two Ply Systems are those methods of ap i e a Base Sheet is mechanically attached or self adhered to the decking. The Cap Sheet shall be attached by Hot Asphalt, Cold Process, Heat Applied, Self Adhered or Mechanically Attached. Minimum thickness shall be 40 mil SBS, APP or approved equal. Base Sheet - The Base Sheet shall be self adhered or mechanically attached to the deck with nails and tin tags, round cap nails or other approved fasteners spaced in accor- dance with the Underlayment Fastening Table I (Page 13 Appendix A). Extend the Base Sheet a minimum of 4" upver- tid surfaces. Base Sheet side laps shall be a minimum of 6" and head laps shall be a minimum of 2". Install the Base Sheet to ensure all valleys are woven past the centerline and through the succeeding course of underlayment on the inter- secting deck to prevent a water lap. Ensure that each course of underlayment is overlapped by the succeeding course at the intersecting roof plane. Proceed up the roof to the ridge. Overlap hip and ridges a minimum of 6. Drip Edge - The Eave and Gable Drip Edge metal shall be installed over the Base Sheet The metal shall be coated with compatible primer prior to the Cap Sheet being installed. The metal shall be fastened 6" on center with. approved fas- teners. All joints shall be lapped a minimum of 3° and sealed with compatible flashing cement, beads of sealant or solid coating at the lap. Continue from eave up the. rake/gable in the same manner, ensuring water shedding. capabilities of all metal laps. Since Raised Fascia and Starter Strips create the same type of water dam situation,they both require an Anti-Ponding System to allow water to flow off the roof at the eave. See Drawing FHW-11. Cap Sheet - The two-ply underlayment flashing options determines the Cap Sheet Installation timing. Choose one of the following and proceed accordingly. Under the Cap Sheet. See Metal Installation. See Drawing F14W-02B • On Top of the Cap Sheet, proceed to the next sec- tion. See Drawing FHW-02C Cap Sheet Installation - Side laps shall be a minimum of 6", head laps shall be a minimum of 3" and back nailed 12" on center with approved fasteners. When using battens, back nailing the Cap Sheet is optional. Install Cap Sheet to ensure all valleys are woven past the centerline and through the suc- ceeding course of Cap Sheet on the intersecting deck to pre- vent a water lap. Ensure that each course of Cap Sheet is overlapped by the succeeding course at the intersecting roof plane. Over lap all hip and ridges by 6°. On Cap Sheet, cut any fishmouths and seal with flashing cement and membrane where applicable. When using Pre -formed Metals without edge returns, the Cap Sheet should terminate I" from the water diverter to ensure adhesion to the primed metal. Cap Sheet Attachment Method - Choose one of the fol- lowing. ° Not Asphalt - Install the Cap Sheet with an application rate of 25 pounds per square t 15% mopping of asphalt The Cap Sheet may come in contact with the Base Sheer, allowing felt to touch felt. lc SeH Aa�ver installed Base Sheet, apply one layer of Self Adhered Underlayment in compliance with the Self Adhered underlayment manufacturer's recom- mendation. Gold process - Install Cap Sheet accordingto underlay- ment(adhesive manufacturers recommendations. For Cold Process Systems in windy conditions, it may be necessary to spot nail Cap Sheet laps at a maximum of Ton center. • Heat Applied - Install Cap Sheet per manufacturers instructions. Mechanical Attachment - Battens may be used with this application method. The Cap Sheet shall be back nailed to the Base Sheet with nails and tin tags, round cap nails or other approved fasteners to secure the Cap Sheet until the flattens can be installed. Windy condi- tions may, require additional securement of the Cap Sheet at the overlaps. Valley Intersection - When installing the Cap Sheet at the valley intersection, choose one of the following installation methods. Be sure that the underlayment does not create a gap due to memory of the material. Full Weave - install underlayment to ensure all valleys are woven past the centerline and through the succeed- ing course of underlayment on the intersecting deck to prevent a water lap. Ensure that each course of under- layment is overlapped by the succeeding course at the intersecting roof plane. Proceed up the roof to the COPYRIGHT 0 FRSAMLE ROOFING INSTITUTE April 2012 If utilizing staples then the battens shall be attached at 12" on center with staples 7/16" crown, No.16 gauge corrosion resistant allowing for 3/4" penetration into roof deck or through the sheathing whichever is less. Staples cannot be used with adhesive set systems. Leave 1/2" space between batten ends and between batten and metal edge returns. Fasteners shall be compatible with batten material. Note: Elevated or counter batten systems require FBC product approval. Contact the roof tile manufacturer for product approval and installation instructions. Tile Installation : Stack tile to facilitate installation and min- imize file movement. See Drawing FHW-19. At the eave clo- sure all fattener penetrations shall be sealed and installed to avoid restricting water flow. Choose one of the following eave closures. • Metal Eave Closure .Install closure strip along eave. .mum on center. If metal closure is inclu- sive of the drip edge, fasten 6" on center. See Drawing FHW-i I. Prefabricated Rubber Eave Closure - Install closure strip along eave. Fasten with minimum three fasteners per 36" strip. See Drawing FHW-1 I. • Raised Fascia/Wood Starter Strip - See Drawing FHW-11. • Prefabricated concrete or day eave closure -Apply per manufacturers instructions. Mortar - Install mortar to elevate eave file on Granular Surfaced underiaymenes only. Apply mortar along the eave edge, applying enough mortar to elevate the eave end of the tile to be on plane with the remaining roof tile. Point and smooth finishflush to eave line. A.mini- mum 318" weep hole flush with the roof underlayment shall beformed at the spacing of not less than one weep hole per tile. RI Flat/Low, Medium and High Profile Tile - Tile shall be attached to resist the aerodynamic moment as determined when using the design pressures for the building and the attachment calculations set forth in the local building code. Starting at the eave, make certain the tile overhangs the drip edge uniformly along the first course. The tile shall over- hang the eave line by atleast3W but not more than 2". Secure tiles with Nails, Screws. Foam/Adhesive or Mortar. See Attachment Resistance Values per Tables I & 2 in Appendix A. Cut/break tile for proper staggering of tile courses when using staggered/cross bond method of installation. Set file in stepped course fashion or in a horizontal and/or vertical fash- ion when utilizing straight bond method. Lay succeeding courses of field file in same manner. Cut/break field file to form straight edge at center of hip/ridge. Valleys - It is not recommended to install trim tile in the val- leys. It may be necessary to remove the lugs from the field the at wells and valley fleshings for proper positioning of cut field tiles. Choose one of the following. • Valley metal without Water Diveners. See Drawing FHW-03. Closed Valley- Miter file to meet at center of valley. See Drawing FHW-03. Open Valley - Chalk a line minimum 2" on both sides of valley center. Place bed of mortar along outside edge of chalk lines on Granular Surfaced undedayment'sonly. Miter file to form straight border and point mortar to finish. See Drawing FHW-03. • Valley metal with Water Diverters. Closed Valley - Miter file to form straight border on either side of water diverters. See Drawing FHW-03. Open Valley - Miter file to forth straight border on either side of the two water diverters. See Drawing FHW-03. COPYRIGHT 0 FRSATILE ROOFING INSTITUTE April 2012 HIP AND RIDGE INSTALLATION General - The following recommendations are only for products approved by the Florida Building Code (FBC) and tested according to SSTD-I I via third parry independent FBC approved laboratories. They will determine the wind upliift limitations of the various hip and ridge attachment methods or by installation methods currently recognized in the High Velocity Hurricane Zone (HVHZ) section of the FBC. There are three basic attachment methodsof the hip and ridge tiles: mechani- cal attachment, adhesive -set and mortar -set attachment systems. The minimum head lap when installing hip and ridge tiles is 2° unless restricted by product design. Any exposed fasteners should be covered with a IN resistant sealant. Field Tile Cuts at Hip or Ridge - All cut field tiles adjacent to a hip or ridge shall be attached to the Cap Sheet and/or the adjacent tile with an approved adhesive, mortar or mechanical fasteners and adhesive. The following table outlines the different parameters for the hip and ridge attachment options. See Drawing FHW-13. MilkM , ✓ 9 B • Foam Mechanical Metal Mechanical or Foam Foam Foam Coating Mortar Mortar Mortar Plastic Foam Foam Foam Coatis Mortar Mortar Wood Fcami H-Bracket Straps Foam Foam Coating Mortar Mortar Mechanical with Adhesive Foam Coating Flexible _Dry Mortar Mortar Foam Mortar Mortar Mortar Mortar Mortar Mortar Hip and Ridge Attachment- Choose one of the following. • Metal Member - Set member in plastic cement or compatible sealant. Fasten 6" on center on each side of the metal flange with minimum I-1/4' ring shank roofing nails. If mechanical attachment of the member is not used, install the member with Foam per the manufacturers instructions. • Plastic Member - Install the member with Foam per the manufacturer's instructions. Wood Member - Fasten 18' on center with four #8 screws per metal strap or H-bracket Each attachment point shall have two fasteners on each side of the wood member. The fasteners shall be spaced .evenly on the metal strap or H-Bracket with the attachment holes parallel to the hip or ridge. The Straps and H-Brackets shall be a minimum of 26gauge. All materials must be compatible with each other. If mechanical attachment of the wood member is not used, install the member with Foam per the manufacturer's instructions. • Mortar - When using Foam or Mortar field the attach - COPYRIGHT O ment, Mortar can be used as a structural attachment. Place a full bed of pre -bagged mortar under the entire tile. Each tile must be fully embedded into the mortar. The field tile secured to the underlayment along with the mortar on each trim tile creates the structural bond. The entire cavity under the trim tile should be filled with approved mortar. Starter Tiles -All starter tiles must be secured at both ends of the file either with mechanical fasteners, mortar and/or adhesive. When the field file is installed with foam or mortar, the starter tile may be installed with an approved mortar. If using a structural member choose one of the following. Metal Member - Place foam under starter tile per manufacturer's recommendations or secure the head of the tile with one #8 screw and apply adhesive in the gap between the structural support and the tile. The member may need to be cantilevered to provide a base for the adhesive. The starter file must make contact with the adhesive. See manufacturer's recommendations. FRSA/TILE ROOFING INSTITUTE April 2012 Plastic Member - Place foam understarter tile per manufacturers recommendations. Wood Member - Place foam under starter tile per manufacturers recommendations or drill a hole in the lower third of the starter file and secure with a mechanical fastener into the wood member a minimum of I", seal the head of the fastener with a UV resistant sealant. Adhesive may be used in lieu of a fastener as long as the wood member has been cantilevered to provide a base for the adhesive. The gap between the structural sup- port and the tile must make contact with the adhesive. See manufacturer's recommendations. Miter or point up the hip starter tile to match the intersecting eaves. After the Starter Tile - Install the next tile centering over the structural support and/or the starter tile. Continue in same manner working from the lowest point toward the highest point of the roof. At intersecting junctions Q.e. hip/ ridge, ridge/gable, ridge/valley), cut tile to forth a solid fit and ensure the first and the last hip/ridge tile is securely fastened. Any exposed fasteners shall be sealed with a UV resistant sealant. Foam must. come in contact with the bottom of the tile and structural support member. Weather Blodd ip and ridge tiles need to have weather mg. Choose one of the following. See drawing FHW-13 for more details. Mortar - Pre -bagged or job -site mix is used to weather block the longitudinal edges of the hip and ridge tiles and provide aesthetics. A full bed of mortar is placed along the longitudinal edges of the hip and ridge tile either during: the application of the hip and ridge tiles or may be packed in after the hip and ridge tiles are installed and the adhesive has cured. Install mortar to seal all voids between the field tile and the hip/ridge tile. Care should be taken to ensure enough mortar is used. The mortar should create a wedge to keep the mortar from dislodging from under the hip/ridge and the field tile junction. Ensure areas we sealed to prevent water entry. Aker the mortar is packed into place, then point up mortar to the desired finish. Foam- used to weather block the entire cavity of the • a joining -planes of field tile to the sides of the structural support This system uses foam as the weather blocking. There is no mortar placed along the longitudinal edges of the hip and ridge tile. Foam is placed where the field tile abuts the structural support. A bead of foam is placed parallel to the hip and/or ridge and the structural ONE- - �71 support to rile junction to act as a weather block and is applied prior to the attachment of the hip and ridge tile. Install foam to seal all voids between the field tile and the structural support. Care should be taken to ensure all areas are sealed with adhesive to prevent water entry. Apply a polyurethane compatible coating to protect the foam from UV exposure. Flexible Self Adhered Membrane - This system can be used with a wood structural support. The flexible self adhered membrane is applied in a continuous or step fashion sealing to both sides of the adjoining field tile a minimum of 2" prior to the mechanical attachment of the trim tile to the wood structural support The flexible flashing may be visible, but should not extend onto the field tile beyond the outside edges of trim tile. Rake/Gable - Choose one of the following. Rake Tile - Cut and install first rake file the exposed length of first course of field tile with factory finish of rake tile towards the eave. Fasten rake tilewith a minimum two I Od nails and/or of sufficient length to penetrate the framing a minimum of 1 ". Abut each succeeding rake tile to the nose of the field tile above and maintain a constant: head lap. Mortar Finish - Place mortar bed along roof edge. Point smooth to a straight edge finish. Wall Abutments - It may be necessary to remove lugs from the field tile and/or install batten extenders at wall flashing for proper positioning of cut field tiles. For mechanically attached tile systems, tiles installed at wall abutment shall be attached with an adhesive. The adhesive shall be installed to the underlayment or the tile below/next to the tile being installed to meet the required uplift. Cut the tile to fit within V of the base of finished wall. Point -up mortar is optional. Plumbing. Stacks/Soil Stacks - Choose one of the following. • Pre -formed Soil Flashing (with returns) - A lead skirt flashing or flexible flashing with minimum 18" x I S' base shall be used. This flashing shall be woven in with the tile coursing. See Drawing FHW-07. • Standard Flashing - Cut file to fit close to plumbing stack; fill void with mortar and point to finish. Coatings - (Optional) Sealer may be applied to exposed mortar. Color coordinated paint may be applied to metal flashings. COPYRIGHT 0 FRSAMLE ROOFING INSTITUTE April 2012 I Boo - UNDERLAYMENT APPLICATION - TWO PLY Self -Adhered 'ne rCr i'IJ3 ]rr tY iws-nt,: ]1T^7C7 cri Tut, 1�'cla'te cffl'cct'er cl 11 tiE rct.-, i rccbi as COPYRIGHT m FRSAMLE ROOFING INSTITUTE FHW-02B rP �=CUIFEU rT- T TAIr¢ n7e } AI'i. �I`tLLn" HN t SEELP =CF: EA,^[.,tL I"` Q.C. U;'! ii��LE P4lIc4 ECJ=[ IFT-L L'P.f LU:c C U.L. , gi- of u :ry t1:5. April 2012 7M EAVE TREATMENT Eave Closure and Anti-Ponding without Sealant FHW-11 FAST=n E E= - l-E =P -.0 ` P'E-rk=F..C'--r. F:ie=Ez PL 110=r Ir0) b- uca] as 31 cl:sj,�. O= 1'E7sl_ 7;,= ;L-:S_P.d =,Eli 1LE •U ��. �• �� cl%. 4: ; it=f 1 LCC - IPP"I T :PTI_IU,_ : L4c11C )ryV:i'g3 ert' V' I lip e'•l' %2 9Jn rs?: rfa\. Jre;: g sYo'.rr dr_i:c Pe r_p6.,3t.0i or of Cl= p-J-; s. .efts ots@ryr'tt odcd '1 •r_�t: axl+ L- i tYcr s:ru� ;r c+. - -i-3s COPYRIGHT O FRSAMLE ROOFING INSTITUTE April 2012 METAL STRUCTURE HIP AND RIDGE SUPPORT -!P r:FD F.D:E i,TTA: D YF'. t--C_E: AP!P "t!' 1."'Hi.S?'c FHW-14A 1`1_7,11 =E= 7,•VJFVT_RER U i.:EtcLd il�fJ' J- !P'P.3,=D FLP. ` _ ME-LL =I? i :D F. D;E FRAVE T_ J11:1 z[VIP3l01. Mill r-.=,;jP,-g_E ,Dn= �=H]IT 1IIIt LRi=EFLAAAE1J- VE-5 AS-•.• bi:d:h: of roJcr ,ca-.z r_lc-+_ :E,.1,.0; '•= r>..ai be ts-.'. M.>Ji I.m Itir,Ln-ss _ C :cl .::JYi:n_I r•J171 z:o's. n� :rruioas rre I'f I u;t; ;'ir-rn.rn's?=. n-I:. COPYRIGHT m FRSAMLE ROOFING INSTITUTE April 2012 FILE COPY MIAM4DADE �-'� - w. REVIRWED FOR DEPARTMENT OF REGULATORY AND ECO �� �` BOARD AND CODE ADMINISTRATION DIYISIO T. p ' 1 /q w'T�E S 1 . LUCI COV A I NOTICE OF ACCEPTANCE (NOA) ' Rnr. . tAt ICP Adhesives and Sealants, Inc. 12505 NW 44m Street Coral Springs, FL. 33065 11 MAY 15 2019 MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Sheet, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 BY St. Lucie County .SCOPE: I ST. Lucie County, Permitting This NOA is being issued under the applicable Hiles and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyset®RTA-1 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 16-0315.03 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0131.02 x' Expiration Date: 01/03/21 l L . Approval Date: 07/12/18 Page 1 of 8 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polyset® RTA-1 as manufactured by ICP Adhesives and Sealants, Inc. as described below in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use with approved flat, low, and high profile roof file systems using Polyset® RTA-l. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polyset® RTA-1 N/A TAS 101 Single component polyurethane foam roof tile adhesive. PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of Polyset® RTA-1 roof tile adhesive. MANUFACTURING LOCATION: 1. Norton, OH. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2842 Water Vapor Permeance ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.71bs./ft.3 8.6 psi Parallel to rise 25 psi 3.2 Lbs./Fe 2.8 perms -0.5% Volume Change @ 700 C., 2 Weeks 95.3% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAMI•DADE COUNTY NOA No.: 18-0131.02 Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 2 of 8 EVIDENCE SUBMTPTED: Test Auencv Test Identifier Test Name/Report Date Southwest Research Institute 01-1208-025 ASTM E 108 06/16/98 PRI Construction Materials FOP-009-02-10 Physical Properties 12/14/10 Technologies, Inc. FOP-009-02-01 TAS-101 11/8/10 FOP-009-02-02 TAS-101 11/4/10 FOP-009-02-03 TAS-101 11/8/10 FOP-009-02-04 TAS-101 11/8/10 FOP-009-02-05 TAS-101 11/8/10 Trinity ERD ICP-SC10045.11.17-1 Physical Properties 11/21/17 NEMO Etc. 4-ICP-18-001.05.18-2 TAS 101 / TAS 123 05/15/18 LIlvIITATIONS: 1. Fire classification is not part of this acceptance. 2. Polyset® RTA-I can be used with flat, low, medium and high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polyset® RTA-1 roof file adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. f 2)—W _ F— MS 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 18-0131.02 MAMFDAD, COUNTY Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 3 of 8 INSTALLATION: 1. Polyset' RTA-1 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of Polyset® RTA-1. 2. Polyset® RTA-1 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polyset® RTA-1 shall provide sufficient attachment resistance to meet or exceed the resistance values determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. Polyset' RTA-1 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. 5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after Polyset' RTA-1 has been dispensed. 6. Polyset' RTA-1 placement shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Typical Placement Detail Weight per paddy (grams) Flat, Low & High Profile # 1 11 High Profile 2-Piece Barrel 92 12 LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. IiA■' UW BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0131.02 Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 4 of 8 ADHESIVE PLACEMENT DETAILS PLACEMENT DETAIL # 1 4banyAertc!» Rits y J_r / Lbc4ric3 Of Tlt« Fvfatn!Ay a• Tie cams-_ L:ne Enn G-ust Llne sava cl-wA 91 Sln:sa-I3d. }• al'ra OmmuEe Lltie �az crane FLAT PROFILE NOA No.: 18-0131.02 Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 5 of 8 Envn raur" line Eavn a.a - PLACEMENT DETAIL # 1 (CONT...) Lr Prr, s MEDIUM PROFILE i?!ui:t.1?aUp 'A i NOA No.: 18-0131.02 Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 6 of 8 GSie {JItT Ea,e PLACEMENT DETAIL # 2 Pm CMa Ftr,G of mo ai fach Rohe TIC Cv=o Lmo HIGH PROFILE P,at1w NOA No.: 18-0131.02 Mru•oanecounm Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 7 of 8 EnYa Lb-m sm PLACEMENT DETAIL # 2 (CONT...) Cni{7-i Puddy &Dell tits wd�( paeCl iS :l Uj Goa - anew nan as: 2•Pictc-camel Pr6e 2-PIECE BARREL PROFILE END OF THIS ACCEPTANCE Tom.:».:-Ctruy by .v. cion I-T'P..:dy }: elje UN:K ,Vl NOA No.: 18-0131.02 Expiration Date: 01/03/21 Approval Date: 07/12/18 Page 8 of 8