HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEMAY 15 2019 Planning & Development Services Department Permitting 0epartln@nt Building & Code Regulations Division St. Lucie county 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: TARPON FLATS LOT 3 - MODEL A FIDE COPY Project Address: 3929 Shore Side Drive Ft. Pierce, FL. Permit #: Occupancy Type: R-3 Construction Type: V-B SCANNED BY INSTRUCTIONS FOR USE: St. Lucie County • This certification must be completed, signed, and sealed by the design professional of record. �Y • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. " Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 170 mph TASD X LRFD End Zone Width: ft 5. Mean Roof Height 14.95' ft Roof Pitch: 6 :12 Parapet: 0 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -41.15 Zone 2: -68.94 Zone 3: -103.1 Zone 4: -45.81 Zone 5: -53.53 Garage: -46.22 7. Design Loads: Floor: NSA PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: NIA PSF Dock: N/A PSF Deck: 177 PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2.500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify\f)kbl�Rti��lliflyypf my knowledge and belief, the attached plans & specifications have been designed to comOYithkl� 6yructural portions of the building codes currently adopted and enforced by St. Lucie cooitv?tl.a1'so certif4i�av;d�i%jural elements depicted on these plans provide adequate resistance to the design fcified: Lo LP , y� ,r ,25r, : D _ Farid Abugaftas 72471 fTl Print Name Cert # & Co. Cert Auth. Cn = �N� '•< TF — Porject Classic iign11 a010w,,, \�, 0t ��/lllllttt�l Revised 07/25/2014 7318 Texas Trail, Boca Raton Florida, 33487 Company Name & Address