Certification for Design Load Compliance
Project Name: TARPON FLATS LOT 3 - MODEL A FIDE COPY
Project Address: 3929 Shore Side Drive Ft. Pierce, FL.
Permit #: Occupancy Type: R-3 Construction Type: V-B SCANNED
BY
INSTRUCTIONS FOR USE: St. Lucie County
• This certification must be completed, signed, and sealed by the design professional of record. �Y
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
" Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 170 mph TASD X LRFD End Zone Width: ft
5. Mean Roof Height 14.95' ft Roof Pitch: 6 :12 Parapet: 0 ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -41.15 Zone 2: -68.94 Zone 3: -103.1 Zone 4: -45.81 Zone 5: -53.53 Garage: -46.22
7. Design Loads: Floor: NSA PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: NIA PSF
Dock: N/A PSF Deck: 177 PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2.500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify\f)kbl�Rti��lliflyypf my knowledge and belief, the attached plans & specifications have been designed to
comOYithkl� 6yructural portions of the building codes currently adopted and enforced by St. Lucie
cooitv?tl.a1'so certif4i�av;d�i%jural elements depicted on these plans provide adequate resistance to the design