Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTBY SCANNED Engineering &Testing Inc. St. LucieCountV 19530 It ble d Drive H.ble,TX 77338 Product Evaluation Report PALRAM AMERICAS, INC. Sunsky 12" 1.0 mm Polycarbonate Light Transmitting Roof Panel Florida Product Approval # 11238.1 R4 Florida Building Code 2017 Per Rule 61G203 Method: 2—B Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Palram Americas, Inc. 9735 Commerce Circle Kutztown, PA 19530 Engineer Evaluator: Terrence E. Wolfe, P.E. FBC ANE ID:1920 Validator• Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1-4 tN rrr,,� C E E�. �b1 CE NSF No. 449 b STATE OF : CL O R FL# 11238.1 R4 October 9, 2017 Compliance Statement: Product Description: Panel Material/Standards: Panel Dimensfon(s): Panel Fastener. Substrate Description: Allowable Design Pressures: FL# 11238.1 R4 rForce Engineering &Testing Inc. 19530 Ramble od Duve Homble,TX 77338 The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.7, 1709.2, 2606, 2609. Sunsky 12" Light Transmitting Roof Panel, 1.0 mm thick Polycarbonate, 1 Y" tall ribs at 12" O.C., 36" Wide, through fastened structural roof panel. Structural Application. Material: Min. 1.0 mm thick Polycarbonate. Thickness: Min. 1.0 mm Width: 36" maximum coverage Rib Height: 1-1/4" major rib at 12" O.C. #12-14 x 1-1/4" HWH SD with 1 1/8" oversize bonded washer or approved equal at 7"-5"-7"-5"-7" fastener pattern. Panel side laps fastened together w/ YV x 1 Y." Grommet at each support then 1'-3" O.C. Corrosion Resistance: Per Florida Building Code 2017, Section 1S07.4.4. Min. 16 Ga. Steel Framing. Framing must be designed in accordance w/ Florida Building Code 2017. Table "A" Mull um Design Pressure: -27.5 psf +35.0 psf Fastener Pattern: 7"-5"-7"-5"-7" 7"-5•7-5"-7• Fastener Spacing: 5'-W O.C. 5'-0" O.C. -Design Pressure Includes a Safety Factor= 2.0. CENSF C�� No. 40 STATE OF P'. 4 '.o�•AiOKI9A Iry se.orrmm. �i PS • . i � October 9, 2017 rForceEngineering & Testing Inc. 19530 Remblevrood Drive Humble,TX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.7, 1709.2, 2606, 2609. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) • FM 4471-92 • ASTM D 635-10 • ASTM D 1929-12 • ASTM E 84-2013A Reference Data: 1. ASTM E 1592-01 Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 273-0027T-08C, D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 273-OO11T-12 3. ASTM D 635-98 SGS U.S. Testing Company Inc. Report No. 676900-02, Class CC2 4. ASTM D 1929-96 SGS U.S. Testing Company Inc. Report No. 528768, Flash Ignition 9820 F, Self Ignition 116Z F 5. ASTM E 84-05 SGS U.S. Testing Company Inc. Report No. 676900-01, Smoke Developed Index 235, Flame Spread Index 15. 6. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: 1. The ASTM E 1592-01 test standard is equivalent to the ASTM E 1592-05(2012) test standard. 2. The FM 4471-10, Foot Traffic Resistance test standard is equivalent to the FM 4471-92, Foot Traffic Resistance test standard. 3. Letter of Equivalency for ASTM D635, ASTM D1929 and ASTM E84 from Architectural Testing, dated October 6, 2017. 1111MI1411�, C E� E.•o �i�i e Ns N lb � STATE OF :or Z ORI9 lot FL# 11238.1 R4 October 9, 2017 rForceEngineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G2G-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturers recommended details. Panel Separation: Panels shall be separated from each other by not less than 4 ft. measured in a horizontal plan unless the building meets one of the exceptions in FBC 2017 Section 2609.2. Area Limitations: See Table 2609.4 (FBC 2017) Panels Shall NOT be Installed in: Groups H, 1-2,1-3 (FBC 2017, Section 2609.1) Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. NtC E' E t �721i CE NSF �Ile A 1; No. 40 10 STATE OF : a; 00 ,n.Ay0ILI9A znV� � 4,f �10 FL# 11238.1 R4 October 9, 2017 SUNSKY 12" POLYCARRONATE PANEL FASTENER LOCATIONS //4' • 1' GnmuEf T S' 5' T 5' ® i'-3' 2'-r BERVEENN SUPi'ORIS d/244 2 11/4' KNH w/ 1 1/0- MMSZE SONDED WAM roX 11111WIS", �•-'No44923 PRE •,.P . CORA ..,,�ON1Ai j111. October 9, 2017 SeoskProfiles BasleDlmunslons and Profile Illustrations Rl�l�l�tl Wftl� SunSky 12" irr __� • r's`I Jr 8mb alFhdde `,psplallsdPr a�una �` ONCE E � <4. ND.44923 *. h October 9, 2017 rForceE eering 8c Testing Inc. 19530 Ramblmoud Drive HmnbleaX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1 Florida Building Code 2017 Per Rule 61G20-3 Method: 2-8 Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Caiport Anywhere 10858 S.E:.County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Gary Hartman, P.E. #73127 Contents: Evaluation Report Pages 1-4 SCANNED W St. Lucie County tttt11111 r rt,#I Jet 6 N C E. E lyp i•�• 1 C E ry S F% •' No. 40e STATE OF ; q P'. OKI ODA sm.errtmt. •• Py; •. 'ti FL# 27403.1 Jv4%�& s8, ;W18 rForceEngineering &Testing Inc 19530 Rambkv d Drive HumbklX 77338 Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 3V Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792'or ASTM A653 G90 Grade 50 29 Ga, Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2. Panel Olmension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: Y" major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x V" HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hammon Rib Wall Panel Maximum Design Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psi Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: 5'-D" O.C. 4-0. O.0 4'-0" O.C. 5--cr O.0 4'-0" 0.11 ' - Substrate: Min.14Ga, Steel Framing Min. 14 Ga. I Steel Framing Min. 14 Ga. Steel Framing Mtn. 18 Ga. Steel Framing Min. 18 Ga. I Steel Framing -Design Pressure includes a Safety Factor-2.0. CENSNo. 40 ef,o' r/. F STATEOF W. i 'P •. ty � 110 FU 27403.1 Ju4%t,18, 2-018 Force Englnectutg STesting Inc. 19530 Rnmblmood Drive Homble,TX77338 Table "a" 29 Ga. Hampton Rib wall Panel Maximum Design Pressure: -57.3 psf -1509 psf ♦3%0 psf a143.1 psf Fastener Pattern: I6'-3'-6'-3"-6"-3'-fi' 6--3'-6'-3'-6'-3"-6" Fastenerspacing: I 4'-W O.C. 2'-0" O.C. 4'-0' O.C. 2'-0' O.C. •Design Pressure Includes a Safety Factor -2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Cade 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance With the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-006OT-18A-E, 667-0061T-IBA-D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering &Testing, Inc. (FBC Organization # AN ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61620-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: - Install per manufacturers recommended details. Insulation: .Manufacturers approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. FL# 27403.1 ,,tµnurztq�b JIV CE NNo. 449 SF Imo, ����yyyy = A• ��77 •� • '�' STATE OF : r � 4 .AioR19A.iv s cnn �i PS • . • 'j. JwPl.e 1.8, 2018 Force Engincening & Testing Inc. 19530 Rnmbl.od Drive Humble lX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report Design Procedure: Based on the dimensions of the structure; appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. 1111111111r1/r11 E, E Ito 1'0 ��V 1 C E N's 4r 10 STATE OF ; Cr 13 4 0 ir; AL 0 RI s GOAw 'ys. 1rm '4rrOrnlpS• %%' FIAT 27403.1 J1,1.1•�.e.18, 2018 26 GA. HAMPTON RIR FASTENER PATTERN 2-1-2-1 112-14 v 3/4' HAH SD3 VI/ 14MM BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6' 3' 6' 3' 6' 3• 6' 3' #12-14 v 3/4" HMI SD3 W/ 14MM BONDED NEOPRENE WASHER MD69i1wi6B CAA do am NO.44923 '•m of STATE 0 ' :'� f 1To1B26t8 FL# 27402.1 1' Force Engineering & Tceting Inc. 19530 nambl..d Drive Hvmbk=77330 Product Evaluatiah Report CARPORTS ANYWHERE Hampton Rib Roof Panel over open framing Florida Product Approval # 27402.1 Florida Building Code 2017 Per Rule 63G20-3 Method: I—D Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. p 449Z3 Florida Evaluation ANE ID: 19ZO Validator• Gary Hartman, P.E. #73227 Contents: Evaluation Report Pages 1-4 ,trtu ugOlrY� C E E Q-. 1 C E Pis No. 4 AB� / SGHa®1V@NhO ®Y St. Lucie County i. ST47E OF :at �rxm �i�� i' ONAI• Jw%e.18, 2018 Force Engineering & Testing Iaa 195301t.blemoad Drive Humble TX 77333 Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Code 2017, Sections 15043.2, 1504.7. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Cade 2017 Section 1507.43. Optional paint finish. Corrosion Resistance: Panel Material shall comply with Florida Building Cade 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 26 Ga.: 0.01850 min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: VV major rib at 9"O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x V" HWH SDp3 with 14mm neoprene banded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga.. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hamoron Rib Rauf Panel Maximum Design Pres]urec -57.3 psF -72.9 psf -67.7 psf •45.9 psf .54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2.1-2-1 - -Panel Span: 5'-0-O.C. 4'-C'O.C. 4'-T O.C. S'-V O.G 4'-0"O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. I Steel Framing Min. 14 Ga. 5[eel FraminC Min. 18 Go. Steel Framing Min. 18 Ga. Steel Framing uesign Pressure includes a Safety Factor= 2.0. FL# 27402.1 ,,41tUu of (yrrr NCE,E ko1 Q�e'V1 CENgF (tea q. �r /� �No. 44➢� / STATE OF ; e ORI axm I,rr'OHfig rFt�,`%% JV4%e.18, 2018 1' Force Engineering & Testing Inc. 39530 Ramblewood Drive Humble,TX 77338 Table "B" 29 Ga. Hampton Rib Roof Panel Maximum Design Pressure: -67.3 psf -250B psf 1 39.0 psf +243.1 psf Fastener Pattem: 6'-3"-6'-3"-6'd'-6' 6'-3"-6'-3"-6"-3'-6' I 6'-3'-6'-3'-6"-3"-6' Fastener5pacing: 4'-0' OX4 2'-0" O.C. 4'-0" D.C. 2'-0" O.C. Design Pressure Includes a Safety Factor= 2.0. Cade Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2, 1504.7: Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Perfarmance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference • FM 4471-92- Foot Traffic Resistance Test Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization 4 TST-5328) Report No. 667-006OT-18A-E, 667-0061T-18A-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization 0 TST-5328) Report No. 667-0060T-18F, 667-00SIT-18E 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44973) @ Force Engineering &Testing, Inc. (FBC Organization 0 ANE ID: 1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under quality assurance program audited by an approved quality assurance entity. FL# 27402.1 14 %•%� 6NCErEtWo CEN^SF< , No. 416e ^'•' STATE OF ;4 sn.arrm. 00 fy� •. 4 �� 03n ,. -rJ. Ju4re,1.8, 2018 rFoxcc Engineering & Testing Inc. 19538 At btemood nave 6 .U-,TX 77338 Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classifimtion is not part of this acceptance. Shear Diaphragm: Shear diaphragm values. are outside the scope of this report Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his dravrings for properfastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. FL# 27402.1 111p1W[t11,4, ``51 S.NCE,E fyo i41 ++i —�t cEfq$ <�. W. 44e9 STATE OF ;, '•� ' 4 FLoRI9A Si Jr.W,.P.18, zo]-s BtOZ 8 I M1f11I5 '. }}�j �i JO AIVIS �.a; E-c6bb'oN ..3 fume vay wpolasuawe 03HSVA1 3H3tldO3H 030NOO WADI /N COS HMH _b/C • 41—Zld N831-Ltld N3N31SV! 819 NO1drm 'V9 6Z 83HSVIA 3N3HdO3N 030NOB PIYIYf //A COS HhW .4/C x bl—ZI%/ 1-Z-1-Z N8311 d N3N3 BBIN NO1dWVH 'V9 9Z