Loading...
HomeMy WebLinkAboutPLANSs M1 EY15TING ONE HOUR FIRE RATED TENANT 5EPPRATION WAI,.L ( U!. DC51GN #U4G5 ) -"- -----.T.- -- - -r -„'- r-- ------------ ---- - Q ❑ D �I T �`9;r�I WdM�N -�\� MEN _ ❑ ❑ A 3 I ELEC. i DINNING AREA PANEL P EL I� \ --J I 3' 0 ' X 6 -8't En LIG�9 FREEZER CHE5T FREEZER HAND - SINK10 w RICE STEAM % 15TING TABLE ARM R AIN MARE TABLE \ \\� COUNTER _3 O 000 KITCHEN F.D.® 3'-O' x T-9/ � m HOOD 2 I ' SOUP 5T0) - r-------- -- -flCE 5PLA5H -3 S�nMa+o�. DEEP PRreR 5-wOr5 - - - -1- - - hOU5E C OKFRobc) H.W. - -- - 15' -- 3 I 000 C/ O a 1EATER FLOOR PLAN SCALE: 1/4"=11-0" EXI5TINC, ONE HOUR FIRE RATED TENANT 5EPERATION WALL ( UL DE51GN #U4G5 ) NEW OR EXISTING 5U5PENDED GRID ACOUSTIC CEILING WALL LEGEND D115T TO REMAIN r� NEW HEIGHT WALL, 3 5/8' METAL 5TUD5, 3 51V METAL I G' O.C. WITH I LAYER Of 5PV GYPSUM STUDS BD. ON EACH SIDE . @ I G. O.C. TOILET FRONT -.7 I 6 (V 8 <V CV dashed area I' 7' " �n knee space min. HAND SINK SIDE TOILET SIDE Grab Bar Detail ADA DETAILS -EI ROCK IDE5 SECTION A N.T.S. A A D A REQUIREMENT NOTES RESTROOM CONDITIONS Toilet paper dispensers must permit continuous paper flow and mounted 1 "-9" center to fin. floor. Hot water and drain pipes under lavatories shall be Insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories. If self closing valves are used on faucets, faucets shall remain open for a minimum of ten seconds. All stresses on grab bars and components shall be based on 250 lb. Paper towel dispenser to be located at a height of 44" above finished floor maximum. block Provide loop type accessible door hardware on toilet stalls. Provide signage on restroom doors adjacent to latch side of door at 60" above fin. floor. Use non -glare finish grade 2 braille and raised letters (1/32"). All doors min. width T-8" dear at 90 degrees open. Storage space Sealed to the EOtIIPNEN'P SCHEDULE (ALL equipment in N.S,F. WPMMetU NO. WO EL NO. MANUFACTURER 1. E RANGE ST VE S AR N.S F. 2. HOOD N.S F. 3. D FR R 2 N.S . 4. S KE U F141ITCOr N.S F. 5. KER [NAI N. F. 6. ST TABL N. F. 7. B EVERAG •AIR N. , . 8. RI 803 JIR SRI N. ,F. 9. 3 MP. 412- 1 3-24 RL GLE N.S.F. 10. HAND S !0 GLE N. ,F. I I . MOPS 412- 2-1 GLE N. ,F. 12. WALK-INC LER N. ,F. 13. HOT WATER TER TC,120 (N GaL l0. SMITH N. ,F. 14. S LVING CUSTOM N. ,F. 15. CO OM N. ,F. l6. T LE steel CU M N. TF. FINISH SCHEDULE FILE COPY KITCHEN AREAS: FLOOR; Vinyl tilts, coved to the walls, commercial grade. WALLS: Stainless Steel behind hood area and FRP paneling in other area. CEILING: 2x4 Lay -in acoustical ceiling, non -perforated non - fissured, smooth, washable, light -in color. Fire -rated. WAITING & EATING AREAS FLOOR; Vinyl tile, coved to the walls, commercial grade. WALLS: Gypsum Firecode painted W/2-coats of epoxy paint, smooth surface, washable. CEILING: 2x4 Lay -in acoustical ceiling, commercial grade. TOILET AREAS: FLOOR: Vinyl tile, coved to the walls, commercial grade. WALLS: Gypsum Firecodc painted W/2-coats of epoxy paint, smooth surface, washable. CEILING: 2x2 lay -in acoustical ceiling, commercial grade. DOOR SCHEDULE NO. DOOR FRAME I SIZE REMARKS 1. FRONTNESTIBULE ALUMINUM/GLASS Y-0" x 7.0 EXISTING 2. REAR EXIT AIdJMIJiJM 3'-0" x T-0" FRP FINISH 3. RSETROOM WOOD 3'-0" x 6' 8" FRP FINISH 4. WALK-IN COOLER ALUMINUM 3'-0" x 6'fi" INSULATED DOOR sea mmllfacturars, ) 1. Latch side clearances at all doorways shall be in accordance w/ADAAG 4.13.16. 2. All exits to be labeled. 3. Interior doors to be labeled as to intended use. 4. All doors to be lever type with door closers and 1 /2" treshold. CURTAIN NOTE: I Intenor counter walls, incluMnq the rex and under I wrfaccs of counters, shall be of easily clearable I and waahable, con5Uwtjon and mill beat least equal to Wtchen wall finmhe5. FRP Coat - - - - - -'-.- - - - Opening FRP Coat Counter _ h T x3'x1" Counter - A - - - - - - - - - 2 1/2" Ht. 1/2"Ht. Stop SIDE FRONT SERVICE COUNTER TOTAL LENGTH: 14'-6" TOTAL HEIGHT: 4' Ow TOTAL WIDTH: Y-0" MATERIAL: 1" thick plywood w/ FRP coshing GENERAL NOTES: 1. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE f'OR ALL WORK AND MATERIALS INCLUDING THAT FURNI$HED BY SUBCOMMAFTORS. 2. DIMENSIONS TAKE PII[ECEDENCF OVER DRAWINGS; DO NOT SCALE DRAWINGS TO DVTERMINE ANY LOCATION, THE OWNER SH,AI.[. BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONN'I"G WITH WORK. 3. ALL CONS U JCf{ON $N ALL COMPLY WITH THE APPLICABLE BUILDINg CODES AND LOCAL IRESTICTI(jNS. 4. IT SHALL BE THE RE3P )NSIBI ITY OF THE CONTRACTOR TO LGCATE ALL EXISTING MECHANICAL. AND ELECTRICAL SERVICQS AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND TO PROTECT THEM FROM DAI!IA% THE CONTRACTOR $HALL BEAR ALL EXPENSE OR RFC OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPEIATI()NS IN CONJUNCTION WITH THE PERFORMANCE OF TIE WOIK 5, ALL WORK SHALL. BE .ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE HIGHEST INDUSTRY STANDARDS, ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. MATERIALS S AND METHODS SHALL CONFORM TO THE APPROPRIATE NATIONAL TRADE BOOKS; I.E. TILE COUNCIL, OF AMERICA, HANDBOOK FOR CERAMIC TILE INSTALLATION; ARCHITECTURAL WOODWORK [NSTIT ITE, "QUALITY STANDARDS." ETC. 6, THE CONTRACTOR SHALL BE RESPONSIBLE, FOR JOB SAFETY, AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKERS AND OCCUPANTS AT ALL TIMES. 1, ALL ELECTRICAL, MECHAMCAL, AND PLUMBING WORK SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS. 8, REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING FIRE PROTECTION SYSTEMS. MODIFICATION TO FIRE PROTECTION SYSTEMS SHALL BE PERFORMED BY A FIRE PROTECTION CONTRACTOR, WHO SHALL OBTAIN A PERMIT FROM FIRE LOSS MANAGEMENT PRIOR TO WORK 9. DECORATIVE MATERIALS, DRAPES, HANGINGS, ETC., SHALL BE NON FLAMMABLE OR FLAME -PROOF PER STATE FIRE MARSHALL REQUIREMENTS. 10, MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE AN I) LOCAL GOVERNING BUILDING CODES/ORDINANCES, CODE CLASSIFICATION: RA -BUILDING CODE: 1. STANDARD BUILDING CODE I J0W I a q? 2. NATIONAL ELECTRIC / 1999 l q q (- 3. STANDARD GAS CODE / 1994 1 q14 7 4. STANDARD MECHANICAL CODE / 1994 1 � q 7 s. LUCTE COUNTY :. 5. STANDARD PLUMBING CODE / 1994 FIRE DISTRICT 6. CABO MODEL ENERGY CODE / 1995 r REVIEWED FORRDCOMPLIANCE 7 . FPA 101 / 1997 fif` 8. STANDARD FIRE PREVENTION CODE / 1994 SUBJUCT TO FINAL FIELD INSPECTION -TYPE OF CONSTRUCTION: II j -OCCUPANCY CLASSIFICATION: B [ �� y ,T B1," / a E: '7- 2-0 -OCCUPANT LOAD: 28 SEATS -BUILDING SQUARE FOOTAGE:1530 SQ. FT.. EXISTING SPRINKLER SYSTEM A H.V.AC. SYSTEM SEE ATTACHED REVISION SHEET FIRE SAFETY NOTE: 2400 Rhode Island Ave. Tel: (90) 462-23' 2 I q q 7 FL Pierce, FL 34950 Fax: (_*61) 462-2333 i. CLASS INTERIOR FINISH PEN.F.P.A. #I01:A 6-5.2. 2. FIRE EXTINGUISHER, PER .F.P.A. #10. 3. KITCHEN SUPPRESSION SYSTEM PROTECTION, PER APPLICABLE PROVISIONS j991N.F.P.A. #96, AS MODIFIED BY THE GSFC. i9q�, MOM 00 Lt RNIaWED sy DArE P & AND PERMIT MUST SS KEPT ON JOB OR NO 1NaPSOTION WILL LSE MADE ELECTRICAL PLAN SCALE:I/411=1141 LEGEND SWITCH DUPLEX CONVENIENCE WALL OUTLET MOTOR F JUNCTION BOX 100CFM FAN FAN MOTOR W/ DISCONNECT —{I} INCANDESCENT LIGHT Wl 10OW BULB HOOD LIGHT 2'0 LAY -IN FLUORESCENT LIGHT FIXTURE rz2'X2' LAY -IN FLUORESCENT LIGHT FIXTURE EXIT / EMERGENCY LIGHT W. BATTERY BACK-UP, EMERGENCY LIGHT W, BATTERY BACK-UP. rLEMT AL MOM & REQUIREMENTS 1, ALL WIRING TO COMPLY WITH N.E.C.,1993 OR LATEST ADOPTED, AND LOCAL REQUIRFMENTS. I MINMUM CBtCUTT TO BE 20 AMP. BREAKER, (2) 412 IN 3/4" CONDUIT (+GND) UNLESS SHOWN OTHERWISE. 3, WERE SIM BASED ON THW COPPER, A.W.G. 4. {PROVIDE DISCONNECTING MEANS AT ALL MOTOR LOADS, 5. VERIFY ALL REQUIREMET•iiTS FOR KITCHEN EQUIPMENT WITH EQUIPMENT SUPPLIER. 6, MAKE ALL FINAL CONNECTIONS. 7. MOUNT ALL ELECTRICAL DEVICES AND SWITCHES AS REQUIRED BY THE ADA AND THE LOCAL STATE BARRIER FREE RULES. 8_ FUSE ALL MOTORS AND MOTOR ASSEMBLIES IN A ACCORDANCE WITH THE N.E.C.1990 AND MANUFACTURERS RECOMMENDATIONS. 9, #ALANCE THE LOADS EVENLY BETWEEN THE PHASES OF THE SYSTEM. MINIMUM UNBALANCE OF 4%. 10, MAINTAIN A MAIM VOLTAGE DROP OF 5% THROUGHOUT THE ENTIRE SYSTEM. 11. cOORDINATE ALL WORK WITH ARCFBTECIURAI., MECHANICAL, AND PLUMBING TRADES IN FIELD. 12. VERIFY ALL EXISTING JOB CONDITIONS AND ACCOMMODATE AS REQUIRED FOR A COMPLETE INSTALLATION. 13. p4E.CTRICAL PANEL SHALL BE ENCLOSED INTO THE WALL. PLUMBING REQUIREMENTS 1. ALL PLUMBING SHALL COMPLY WITH THE LOCAL PLUMBING & HEALTH DEPARTMENT REWRENIENTS. 1 INSULATE ALL HOT & COLD WATER LINES ABOVE GRADE WITH 3W FIBERGLASS PIPE INSULATION, WITH VAPOR BARRIER, 3. VERIFY ALL FINAL CONNECTIONS TO KITCHEN EQUIPMENT WITH KITCHEN SUPPLIER VERIFY ROUGH -IN REQUIREMENTS WITH SAME. 4. MATERIALS SHALL BE AS FOLLOWS: A: WATER PIPING TO BE TYPE'K' COPPER BELOW GRADE, TYPE U COPPER ABOVE GRADE. B: WASTE PIPING TO BE CAST IRON, OR PVC PLASTIC. C: VENTS TO BE CAST IRON, GALVANIZED STEEL, OR PVC PLASTIC PIPE D: GAS PIPING TO BE SCHEDULE 40, BLACK STEEL PIPE. PROVIDE AUTOMATIC GAS SHUT-OFF VALVE IN COOKING EQUIPMENT SUPPLY MAIN AS REQUIRED FOR COOKING EQUIPMENT FIRE PROTECTION SYSTEM, VERIFY & COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. 5. ALL WDERECT WASTES EXCEEDING 24" IN LENGTH SHALL BE TRAPPED. 6. PROVIDE CLEANOUTS REQUIRED, & AT THE BASE OF ALL STACKS, 7. ALL MATERIALS USED WITHIN RETURN AIR PLENUMS SHALL BE APPROVED FOR SUCH USE. 8. PROVIDE FIXTURE STOPS AT ALL PLUMBING FIXTURES. 9. PROVIDE ALL FITTING & ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION. 10. HOT WATER SUPPLIED TO LAVATORY FIXTURES SHALL NOT EXCEED 120°F. 11. HANDICAP PLUMBING FDXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE ADA RBQUR MUM & LOCAL STATE BARRIER FREE REQUIREMENTS . 12. COORDINATE ALL WORK IN FIELD WITH ARCHITECTURAL, MECHANICAL & ELECTRICAL TRADES. 13. VERIFY ALL EXISTING JOB CONDITIONS & AS REQUIRED FOR A COMPLETE INSTALLATION. PANEL: B MAMS: 100A P DfbCRJFION PANEL SiCHEDULE VOLTAGE: IP1208V PHASE: 3 : 4 MPUNTING: SURFACE RE R 1 WAl 5 I CK7 CKT ATT R DE5CRIPTIQN c •uo c � •in nin A R i- I IF 4 IIII�III�9 1111111111©Im� IIIIIILI�lllllllllll-L7�'YY7%��.� I m !'mom TOTAL CONNECTED LOAD I � - g�� 3 I/2' AUTO GAS 5HUT-Off VALUE3l4' I/2" h�o 2W 12160 1 1920 1 L 21GO 1 1440 1 1760 5040 2 AMP5 21 MOOAMPS GA5 GAS RISER DIAGRAM 3680 30.1 AMPS METER AMP5 34 PANEL: A I PANEL SCHEDULE MAINS: 100A MLO VOLTAGE: DE5CRIPTION BREAKER POLE AMP A 1201208V WATTS B I C CKT NO, PHASE: CKT N0. 3 WME: 4 WATT5 A B C MOUNTING: SURFACE BREAKER DE5CRIPTION AMP POLE KJTCHEN AREA UGHT5 I 20 1200 1=' "__ `=`'I`:' I 2 1800 ............... -::'.:::.::' 720 20 DINING AERA UGHT5 TOILET LIGHTING IFAN I 20 i:iT::. ```'' ::yam.._ 3 4 6 . :::::: EiLI=:= I TOILET LIGHTING /PAN WALK-IN COOLER 20 ......:............ __ 5 _ - ` _' 480 20 I OUTLET( OUNTER ) 20 840 ......._...:....... ........_ ............. __=:: 7 8 4b0 i5:ccccs.: --- _ : '- : 20 I OUTLET(DINING ) I TOTAL FOR PHASE TOTAL CONNECTED LOAD 2040 1 1 4320 36 AMP5 2280 19 AMP5 1320 11 AMP5 2 Tr `L ' G G� a PLUMBING RISER N.T.S. AMPS 22 i-1 2' KITCHEN 51NK OR EQUIP. (Tl'P.) 112' 'ALL EQUIPMENT ARE TO BE INDIRECTLY DRAINED EXCEPT HAND 51NK5 AND MOP 51NK INDIRECT WASTE DETAIL ( TYPICAL ) CALCULATION FOR GREASE INTERCEPTOR WOK SINK: 18'XI8'X12"= 3888 Cl/231= 16.8GPM 0.75=12.6GPM = 30LB. INTERCEPTOR 3-COMP. SINK: 3X(20"XI8'XI4")=15,120 Cl/231=65GPM 0,75= 48 GPM=IOOLB. INTERCEPTOR FRANK D. MILET4 A.I.A. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 (908)80 ARCHITECT -PROFESSIONAL PLANNER CHINA GARDEN AlOW _ L "m 4836-4838 NORTH KINGS HIGHWAY FT,PIERCE, FL SCALE: 1/4"=l'-O" DRAWING NO.: 165W DRAWN BY: JU DAT& (17103)% E F, G-1 (2 of 3 ) RBVIBED: 07/11/00 FOOD SERVICE CONSULTANT LAM CONSULTING COMPANY, INC. 108 MADISON STREET, NEW YORK NY 10002 PHONE: 212 - 732. 3450 FAX: 212. 732 - 9145 _r .I. _r "I' _r _r I I I I I I � � _L A- � PriRO CHEM MODEL # PCL3.50/3.50 LIQUID UL 300 FIRE 5UPM5510N 5Y5TEM W127 112 FLEM POINT5, AUTOMATIC GA5 VALVE REMOTE MANUAL PULL STATION MIN. 10" FROM HOOD 5PRI N KLEK5 FLOOK PLAN 5CALE: 114" = I' —on 4m FU5IBLE LINK 360 DEGREE5 GRANG NOZZLE5 MODEL 96508 R NOZZLE Rlce Cooker Smoke 1 OL15e PLENUM NOZZLE5 #NLA 0 MODEL 965( GRW NOZZLE Back 51a5h Wok Stove PLENUM NOZZLE5 #NLA HOOD FIRE SUPPRESSION SYSTEM T.S. FUSIBLE LINK PLENUM NOZZLE5 360 DEGREE5 #NLA MODEL 96982 P NOZZLE 09, TUt110 O EXISTING 1 /2" DRIF. PENDENT CHROME STNDRD 155' -`� RELOCATE 1/2" DRIF. PENDENT J CHROME 9TNDRD 155' ---- EXISTING PIPE --- NEW PIPE --- EXISTING FIRE_ WALL 27z2z 1--HOUR RATED FIRE WALL EXI5TING ROOF 5Y5TEM EXI5ING STEEL BAR C.11k ,TTarls: HOQD-A: 4' x 21' p 100 = 8400 CFM FAN: 2HP(1) EXHAUST, 341? MAKEUP MAKEUP AIR: 8% x 8400 = 7146 CFM EXHAUST DUCT $U: (16r x 161 x 2 / IN - 3.6 SQ. FT. EXHAUST WCr AM VELQCM: 7140/ 3.6 =1"3 FPM MAK&UP AJR 1E QUC7 SIIE: OV" x 41144 = Sb SQ, PT. MAKEUP AW DUCT SIZ� 26" x W = j.6 SQ.Fr. 1n• IQ-0 IO- 2 HP 2 HP Exhaust Fan 3 7p Exhaust Fan M e-up Air F n V V Non-Combu5t*Me Roof Air Air f Flow Now F.n Hexible Duct Finn Dud G A N F Hood -A Length 21,47- 12 Z M'"' Rce _ Cooker 5moke Back 51ash House Wok 5tove m SIDE FRONT HOOD -A VENTILATION PLAN (N.T.S) 1/2" CHAIN ANCHORED TO EX15T'G 51LI5PENED CEILING 5Y5TEM EXI5TING STUD WALL 16 GUAGE STAINLESS STEEL ANGLES r ANCHORED TO HOOD 4 JOISTS I G GUAGE 5TAINLE55 5TELL CLIP MOO[) BRACKET5 ANCHORED TO WALL 5.5. ON 5/8" 5H. IRK SECTION 112" =1'-0" I Deep Frye HOOD -A TOP VIEW (N.T.S.) Air Flow NOTE: AN5UL 5Y5TEM TO BE FILED BY FIRE EXTINGUISH CONTRACTOR Gelling 41;1 FRANK D. MILETO A.I.A. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07883 (908)8SSIO0 ARCHITECT -PROFESSIONAL PLANNER M06W HOOD ISOMETRIC VIEW Zia" = 11-0" U15TING ONE HOUR MIRE RATED TENANT 5EPERATION WALL ( UL DE51GN #11_114G5 ) ❑D ❑ ❑ ❑ D ❑ D __ -4�- ❑ D ❑ D ❑ D I MEN WOMEN \ J -I -- LEC. DINNING AREA PANEL P EL I 3' x6-8�-- D ❑ ❑ D DID WALK-IN COOLER' I I I I D o ❑ D ❑ D 8-o4xe' // �� FREEZER CHE5T FREEZER /-/ � -\ w RICE 5TE/JNI TABLE WARMER TAR IN TABLE KITCHEN J F.D.® HAND HOOD 21' 50UP5TOVE SINK F - - - - - - - - - - - ---------- -5f 0Kf-- ICE 5PLA5H 5, I 5AIAMANDER DEEr FRYER WOKS HOUSE KER GU H W HEATER 3'--i � o 0 0 o O I �. o I ,® o 3'-0' x T O" ) i --------------- ----- -- -- - -- -- - - - ---, ------ 1 _1 FLOOR PLAN SCALE: 1/40'=11-011 EXI5TIN ONE HOUR FIXF1cT0TENANT 5EPERATION WALL ( UL DE51GN #U4G5 ) NEW OR EXISTING SUSPENDED GRID ACOU5TIC CEILING _ WALL LEGEND EX15T TO REMAIN ////:P7� NEW HEIGHT WALL, 3 5/8' METAL 5 T JD5, 3 5/8' METAL I G" O.C. WITH I LAYER OF 5/5' GYP5UM STUDS BD. ON EACH SIDE. @ I G' O.C. TOILET FRONT dashed area 1'-7' • min knee space min. tMo PINK SIDE Grab Bar De all ADA DETAILS °ET ROCK IDES SECTION A N.T.5. A A D A REQUIREMENT NOTES RESTROOM CONDITIONS Toilet paper dispensers must permit continuous paper flow and mounted 1"-6 center to On. floor. Hot water and drain pipes under lavatories shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories. If self closing valves are used on faucets, faucets shall remain open for a minimum of ten seconds. All stresses on grab bars and components shall ba based on 250 lb. bock Paper towel dispenser to be located at a height of 44" above finished flow maximum. Provide loop type accessible door hardware on toilet stalls. Provide slgnage on restroom doors adjacent to latch side of door at 60" above fin. floor. Use non -glare finish grade 2 braille and raised letters (1/32"). All doors min. width 2'-8" clear at 90 degrees open. Storage space Sealed to the EQUIPMENT SCHEDULR (ALL equipmeat are N,S.F. approved) EQUIPMENT MODEL NO. MANUFACTURER CHINESE RANGE STO FSR-500 RED -STAR N..F. D 211-V WIN N.S.F. R FRYER 2 #1 PITCO N.S.F. SMOKEHO SE WSH-200 WIN N..F CE COO RER-55A RINAI N. F. TAB -3 WIN N. F. 7. BAIN 60-24M BEVLl AIR N.S.F. 8. CE TIIA-803 ZORRU N.S.F. 9. 3702. 41-22-3-24 RL EAGLE N..F. 10, SINK HSA-10 EAGLE N..F. I1. OP SINK 41 -22-1 EAGLE N..F. 12. ALK-IN COOLER 8' " x 8'-0" AMERLKOOLER N.S.F. 13. OT WATER HEATER -120 50 A.O. SMITH N.S.F. 14. 01VING TOM WIN N.S.F. 15. COUNTER CUSTOM WIN N.S.F. 1.6. TABLE islaiWen doe1 CUSTOM WIN N.S.F. FINISH SCHEDULE KITCHEN AREAS: FLOOR: Vinyl tile, coved to the walls, commercial grade. WALLS: Stainless Steel behind hood area and FRP paneling in other area. CEILING: 2x4 Lay -in acoustical ceiling, non -perforated, non - fissured, smooth, washable, light -in color. Fire -rated. WAIMG dR EATING AREAS: FLOOR: Vinyl tile, coved to the walls, commercial grade. WALLS: Gypsum Firecode painted W/2-coats of epoxy paint smooth surfac4:, washable. CEILING: 2x4 Lay -in acoustical ceiling, commercial grade. )1LET AREAS: FLOOR; Vinyl file, coved to the walls, commercial grade. WALLS: Gypsum Firecode painted W/2-coats of epoxy paint smooth surface, washable. CEILING: 2x2 Lay -in acoustical ceiling, commercial grade. DOOR SCHEDIILE NO. DOOR FRAME SIZE 1. FRONTNESTIBULE ALUMINUMMLASS -0" x T-0" G 2. ITAR M ALUMINUM 3'-0" x T-0" FRP FINISH 3. ItSETROOM WOOD '4" x 6'-8" RP FINISH 4. WALK-IN COOLER ALUMINUM 3'-V x 6W INSULATED DOOR see manufacturers, DOOR NOTES: 1. Latch side pleerances at all doorways shall be in accordance w/ADAAG 4.13.16. 2. All exits to be labeled. 3. Interior doors to be labeled w to intended use. 4. All doors to be lever type with loot' closers and 1/2" treshold. DRAri CWTAIN N07: i Interior counter( wads, mcWwlq the tar and imdtr wrf ices of courtiers, shah be of e" %ply clearable and washable, construction and Oil be at least eq4 to wchen wall hnehes. FRP Coat --S+K- - - - - - - - - opens FRP Coat Counter 3'x3'x1" Counter � Accessab 2 1/2" Ht. stop SIDE FRONT SERVICE COUNTER TOTAL LENGTH: 14'-6" TOTAL HEIGHT: 4'-0" TOTAL WIDTH: T-0" MATERIAL: 1" thick plywood w/ FRP coating GENERAL NOTES: J. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND S14AU BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THAT FURNISHED BY SUBCONTRACTORS. Z. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS; DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATION. THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONTINUING WITH WORK. 3. ALL CONSTRUCTION SHALL COMPLY WITH THE APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. 4. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND TO PROTECT THEM FROM DAMAGE, THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF AE WORK. 5. ALL WORK SHALL BE ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE HIGHEST INDUSTRY STANDARDS. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. MATERIALS AND METHODS SHALT. CONFORM TO THE APPROPRIATE NATIONAL TRADE BOOKS; I.E. TILE COUNCIL OF AMERICA, HANDBOOK FOR CERAMIC TILE INSTALLATION; ARCHITECTURAL WOODWORK INSTITUTE, "QUALITY STANDARDS." ETC. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SAFETY, AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKERS AND OCCUPANTS AT ALL TIMES. 7. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS. & REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING FIRE PROTECTION SYSTEMS. MODIFICATION TO FIRE PROTECTION SYSTEMS SHALL BE PERFORMED BY A FIRE PROTECTION CONTRACTOR, W140 SHALL OBTAIN A PERMIT FROM FIRE LOSS MANAGEMENT PRIOR TO WORK, 9. DECORATIVE MATERIALS, DRAPES, HANGINGS, ETC., SHALL BE ?DON FLAMMABLE OR FLAME -PROOF PER STATE FIRE MARSHAL.L REQUIREMENTS. 10, MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. CODE CLASSIFICATION: -BUILDING CODE: 1. STANDARD BUILDING CODE / 1994 2. NATIONAL ELECTRIC / 1999 3. STANDARD GAS CODE / 1994 4. STANDARD MECHANICAL CODE / 1994 5. STANDARD PLUMBING CODE / 1994 6. CABO MODEL ENERGY CODE / 1995 7. NFPA 101 / 1997 8. STANDARD FIRE PREVENTION CODE / 1994 -TYPE OF CONSTRUCTION: U -OCCUPANCY CLASSIFICATION: B o 1 "-', -OCCUPANT LOAD: 28 SEATS -BUILDING�&UUARE FOOTAGE:1530 SQ. FT., A ,,� , EXISTING SP SYSTEM & H.VA.C. SYSTEM FIRE SAFETY NOTE: a 8 ra' L CLASS INTERIOR FINISH PER 1991 N.F.P.A. #101:A-6-5.2. as a c "Y 2. FIRE EXTINGUISHER, PER 1991 N.F.P.A. #10. 3. KITCHEN SUPPRESSION SYSTEM PROTECTION, PER APPLICABLE^ s r PROVISIONS 1991 N,F.P.A. #96, AS MODIFIED BY THE GSFC. CE J u Ri ca rt C� i Of LL LIE COUNTY y y 3 1 BUILDING DIVI®ION te7 J' 3 3 0 I novinwED FOR 60 LI Q) by DATE (i - D o o _ _Q LA 8A Ra PZA-MIT a3i is V U'Gt , sMkrEt tCiMA e7M r0�4)A 06 N Ci4111WY*UNMADE Pe Cr ,^, r� 0 ,° FRANK D. MILETO A.I.A. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 - iv W (8a8)80 ARCHITECT -PROFESSIONAL PLANNER " "10m 4uamua» SCALE: 1/4"=F-0" DATE: 07/D3/00 CHINA GARDEN --no 111� 4836-4838 NORTH KINGS HIGHWAY c0 r I , FI'.PIERCE, FL 1 DRAWING NO.: 16500 A-1 (lof3) DRAWN BY: J1J REVISED: 071111/00 REVISED: 0'7/2tt/00 FOOD SERVICE CONSULTANT LAM CONSULTING COMPANY, INC. 108 MADISON STREET, NEW YoRK, NY 10002 PHONE: 212-732-3450 FAX_- 212-712-V45 o v nC) vy Ql =3 y L E C4 c I rr) C �- .� cx2 vm SI/ iC�S yr ELECTRICAL PLAN scALE:I/4"=11-0" LEGEND SWITCH DUPLEX CONVENIENCE WALL OUTLET 0 MOTOR Ul JUNCTION BOX 4 100CFM FAN FAN MOTOR WI DISCONNECT --(�-- INCANDESCENT LIGHT Wl 10OW BULB c� HOOD LIGHT 2'x4' LAY4N FLUORESCENT LIGHT FIXTURE 212' LAY4N FLUORESCENT LIGHT FIXTURE EXIT I EMERGENCY LIGHT W. BATTERY BACK-UP. EMERGENCY LIGHT W, BATTERY BACK-UP. ELECTRICAL NOTES & REQUIREMENT$ 1 ALL WIRING TO COMPLY WITH N17 C.,1993 OR LATEST ADOPTED, AND LOCAL REQUIREMENTS. 2. MMeUM CIRCUIT TO BE 20 AMP BREAKER, (2) 412 IN V4' CONDUIT (+GND) UNLESS SHOWN OTHFRWIS 3. qTRF SIZES BASED ON THW COPPER, A.W.G. 4. PROVIDE DISCONNECTING MEANS AT ALL MOTOR LOADS. 5, vERFY ALL REQUIREMENTS FOR KITCHEN EQUIPMENT WITH EQUIPMENT SUPPLIER. 6. MAKJ: ALL FINAL CONNECTIONS. 7. MOU11T ALL ELECTRICAL DEVICTS AND SWITCHES AS REQUIRED BY THE ADA AND THE LOCAL STATE BARRIER FREE RULES. g, FUSE ALL MOTORS AND MOTOR ASSEMBLIES IN A ACCORDANCE WITH THE N.E.C.1990 AND MANUFACTURERS RECOMMENDATIONS. 9. BALANCE THE LOADS EVENLY BETWEEN THE PHASES OF THE SYSTEM. MINIMUM UNBALANCE OF 3%. 10, MAINTAIN A MAXIMUM VOLTAGF. DROP OF 5% THROUGHOUT THE ENTIRE SYSTEM. I I. COOR DINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING TRADES IN FIELD. 12, VERIFY ALL EXISTING JOB CONDITIONS AND ACCOMMODATE AS REQUIRED FOR A COMPLETE INSTALLATION. 13, ELECIRICAL PANEL SHALL BE ENCLOSED INTO THE WALL, 1. ALL PLUMBING StKL COMPLY WITH THE LOCAL PLUMBING & HEALTH DEPARTMENT REQUIREMENTS. 2. INSULATE ALL HOT & COLD WATER LINES ABOVE GRADE WITH 3/4" FIBERGLASS PIPE INSULATION, WITH VAPOR BARRIER. 3. VERIFY ALL FINAL CONNECTIONS TO KITCHEN EQUIPMENT WITH KITCHEN SUPPLIER VERIFY ROUGH -IN REQUIREMENT'S WITH SAME. 4. MATERIALS SHALL BE AS FOLLOWS: A: WATER PIPING TO BE TYPE %' COPPER BELOW GRADE, TYPE T.' COPPER ABOVE GRADE. B: WASTE PIPING TO BE CAST IRON, OR PVC PLASTIC. C: VENTS TO Bk CAST IRON, GALVANIZED STEEL, OR PVC PLASTIC PIPTS. D: GAS PIPING TO BE SCHEDULE 40, BLACK STEEL PIPE, PROVIDE AUTOMATIC GAS SHUT-OFF VALVE IN COOKING EQUIPMENT SUPPLY MAIN AS REQUIRED FOR COOKING EQUIPMENT FIRE PROTECTION SYSTEM. VERIFY & COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER. S. ALL INDIRECT WASTES EXCEEDING 24' IN LENGTH SHALL BE TRAPPED. 6, PROVIDE CLEANOUTS REQUIRED, & AT THE BASE OF ALL STACKS. 7. ALL MATERIALS USED WITHIN RETURN AIR PLENUMS SHALL BE APPROVED FOR SUCH USE. S. PROVIDE FIXTURE STOPS AT ALL PLUMBING FIXTURES. 9. PROVIDE ALL FITTING & ACCESSORIES AS REQUIR) D FOR A COMPLETE INSTALLATION. 10. HOT WATER SUPPLIED TO LAVATORY FDLTURES SHALL NOT EXCEED WE 11. HANDICAP PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE ADA REQUIREMENTS & LOCAL STATE BARRIER FREE REQUIREMENTS. 12. COORDINATE ALL WORK IN FIELD WITH ARCHITECTURAL, MECHANICAL & ELECTRICAL TRADES. 13. VERIFY ALL EXISTING JOB CONDITIONS & AS REQUIRED FOR A COMPLETE INSTALLATION. G� PANEL: B PANEL SCHEDULE MAINS: 100A MLO VOLTAGE: 12MOSV PHASE: 3 WIRE: 4 MOUNTING: SURFACE DESCRIPTION BREAKER WATTS CKT N0, CKT N0, WATTS BREAKER DESCRIPTION POLE AMP A B C A B I C AMP POLE FREEZER I 20 -s I 2 %0 20 1 C11E5T FREEZER OUTLET {KITCHEN) I 20 _ 240 3 5 4 6 960 20 30 1 3 RICEWARMER MAKE-UP FAN UHAUS FAN 3 30 3 960 7 8 960 V 30 3 30 960 9 10 0 30 3 EXHAUST FAN 3 ; _ :' 9601 11 1 12 20 BAINMA I 20 1 1 1 OUTLET (KITCHEN ) TOTAL CONNECTED LOAD 12320 AMP$ 34 6 PANEL: A PANEL SCHEDULE MAINS: 180A MLO VOLTAGE: 12WMV PHASE: 3 WIRE: 4 MOUNTING: SURFACE DESCRIPTION BREAKER I WATTS CK1 NO. CKT NO, WATTS I (BREAKER DESCRIPTION POLE AMP A B L' A B C AMP POLE KITCHEN AREA LIGHT5 1 20 t ;ilii`_ ;_ I 2 i _:' ` U IEE!t;€ 20 1 DINING AERA LIGHTS TOILETUGHTING/FAN I 20 =' .:-. 720 3 4 _'_. 720 1 TOILET LIGHTING/FAN TOTAL FOR PHASE I A m TOTAL CONNECTED LOAD 7920 /t \ 2 I T\ o \ > PLUMBING RISER N.T.S. AMP5 22 2Y n► 1 ��2 2' 112' 112' AUTO GA5 SHUT-OFF VALVE 'Z"4o, �3/4" GA5 METER 2" MINIMUM ) 6 h 112" GAS RISER DIAGRAM KITCHEN SINK OR EQUIP. [Il j "ALL EQUIPMENT ARE TO BE INDIRECTLY DRAINED EXCEPT BAND SINKS AND MOP 51NK INDIRECT WASTE DETAIL ( TYPICAL ) CALCULATION FOR CREASE INTERCEPTOR WOK SINK: 18'XIB'X12'= 3088 Cl/231= 16.86PM 0.75=12.613PM = 30LB. INTERCEPTOR 3-COMP, SINK: 3X(20'X18'XI4')=15,120 Cl/231=65GPM 0.75= 48 GPM=IOOLB, INTERCEPTOR FRANK D. MILETO A.I.A. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 (eM)eeaoo lw ARCHITECT -PROFESSIONAL PLANNER CHINA GARDEN AXOMt Lmem4m 4836-4838 NORTH KINGS HIGHWAY FT.PIERCE, FL SCALE: 1/4"=1'-Q" 1 DRAWING NO.: 16500 DRAWN BY: 1 DATE! 07/03/00 1 E,P,G-1 (2 of 3) REVISED: 07/11/00 REVISED: OV213/00 13000 SERVICE CONSULTANT LAM CONSULTING COMPANY, INC. 108 klAD" STREET, NEW YORK. NY 10W2 PHOW:212.732-3460 FAX: 212 . 732 - 9146 EXI5TING T T T T T T ly I Ij1NEW2 I I i I I ENI�I I I I I WALK-IN COOLER I 1 18'-C X 8'-0- i I I I I I I sl NEW I I I I�DRY ENDENT I I 1 x I I i I y I^I rL ____--_-__L-_______-- I I I I I I I PYRO CHEM MODEL # PCL3.50/3.50 LIQUID UL 300 FIRE 5UPPRE55ION 5Y5TEM W/27 112 FLEM POINT5. REMOTE MANUAL PULL 5TATION MIN. I (I FROM HOOD AUTOMATIC GAS VALVE SPRINKLERS FLOOR PLAN SCALE: 1/4" = P-ON 4111111110 FU51BLf LINK 360 DfGP.EE5 GP.ANG NOZZLES MODEL 96506 R NOZZLE RIGP, Cooker Smoke HOU5e PLENUM N022LE5 #NLA MODEL GKW N( Back 51a5h Wok Stove PLENUM NOZZLE5 #NLA PLENUM NOZZLE5 #NLA MODEL %982 P NOZZLE HOOD FIRE SUPPRESSION SYSTEM (N.T.S.) 4mI FU51B(:E LINK 360 DEGREE5 SYMBOL: _ EXISTING 112" DRIF. PENDENT CHROME STNDRD 155' -`yam RELOCATE 112" DRIF. PENDENT �J CHROME STNDRD 155" - - - - EXISTING PIPE CALCULATIONS: HOOD -A: 4' x 21' x 100 - MM CFM FAN: 2HP(2) EXHAUST, 3HP MAKE-UP MAKE-UP AIR: 85% x &W-7140 CFM EXHAUST DUCT SUE: (16" x 16") x 21144 = 3.6 SQ. FT. EXHAUST DUCT AIR VELOCITY: 714013.6 s1993 PPM MAK&UP AIR FLEM E DUCT SIZE: 48"" x 4 / 144 =,5.6 SQ. Ff, MAKE-UP AIR SrEa DUCT SIZE: 26" x 28" . 5.6 SQFT. In. 10-'7 in. 10' 2 HP Exhaust Fan --�'7 M up Air F n --- NEW PIPE 11 EXISTING FIRE WALL L Non-Combustable Roos At Air Air '7777f; 1-HOUR RATED FIRE WALL e Flow Flow .0 Mskevp Air E Fm Mwt D IF Pace —� Min. Cooker 5moke Back 5t.,sh House N co0 Wok gt.,n 71A�- I " SIDE FRONT HOOD -A VENTILATION PLAN (N.T.S. EXI5TING ROOF 5Y5TEM EX151NG 5TEEL BAR, J015T5 EX15TING 16 GUAGE 5TAINLE2 BRACKETS ANCHC AIN ANCHORED TO 51-15PENED CEILING 5Y5TEM kGE 5TAINLE55 STEEL ANGLE5 )RED TO HOOD 4 J015T5 SECTION 112• = Ir-0• HOOD ISOMETRIC VIEW 1/4" = 1'-0* HOOD -A TOP VIEW (N.T.S.) 2 HP Exhaust Fan Air -- Flow NOTE: f AN5UL 5Y5TEM TO BE FILED B)' jl FIRE EXTINGUI51-1 CONTRACTOR Cahng A FRANk D. MILETO A.I.A. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 ARCHITECT -PROFESSIONAL PLANNER CHINA GARDEN 4836-4838 NORTH KINGS HIGHWAY FrYIERCE, FL SCALE: 1/4"-1'-0" DRAWINO NO.: 16.500 DRAWN BY: JLJ DATE: 07/03/00 S,V,F-1 ( 3 of 3) REVISED: 07/11/00 REVISED: (7/28/00 FOOD SERVICE CONSULTANT LAM CONSULTING COMPANY, INC. 108 MADISON STREET, NEW YOFtK NY IM02 PHONE:212-132-3450 FAX 212-732-9145