Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ter,■ No .www%,t Project Name: Johnson Residence Builder Name: Street: XXX Pinecone Lane Permit Office: St. Lucie County SCANNED City, State, Zip: Fort Pierce , FL, 34945 Permit Number: p� Owner: Johnson Residence Design Location: FL, Pierce Jurisdiction: St. Lucie County ®® County: St. Lucie Climate Zone 2 St..Lucie.Coun Fort (Florida ) I. New construction or existing New (From Plans) 9. Wall Types (2900.0 sqft.) Insulation Area 2. Single family or multiple family 9 y p y Single-family 9 y a. Concrete Block - Ext Insul, Exterior R=4.1 2660.00 ft' b. Frame -Wood, Adjacent R=11.0 240.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2957.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2957.00 ft2 6. Conditioned floor area above grade (ft2) 2957 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(365.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 135 a. U-Factor: Dbl, U=0.65 168.33 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=o.65 166.67 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.0 SEER:16.00 c. U-Factor: Gbl, default 30.25 ft2 SHGC: Clear, default 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 11.799 ft. Area Weighted Average SHGC: 0.302 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2957.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2957.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft, 15. Credits CF, Pstat _ Glass/FloorArea: 0.124 Total Proposed Modified Loads: 87.03 PASS Total Baseline Loads: 92.53 1 hereby certify that the plans and specifications covered by Review of the plans and f-TUE Sr4 , this calculation are in compliance with the Florida Energy specifications covered by this y� _ Code. calculation indicates compliance y riq °l Wth the Florida Energy Code. 1, till" sW"1••� PREPAQ:V don Before construction is completed DAT 4-22-1 this building will be inspected for compliance wrath Section 553.908 )� y I y certify that t ' bu I ' , as designed, is in compliance Florida Statutes. CDD the orida E gy C WE f�J BUILDING OFFICIAL: DAAja�DATE: - Compliance requires certific tion by th air handler unit manufacturer that the air handler enclosure qualifies as certified factory -seated in a cordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/22/2019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLI5T REPORT PROJECT Title: Johnson Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2957 Lot # Owner Name: Johnson Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: XXX Pinecone Lane Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL , 34945 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2957 29570 SPACES Number Name Area Volume Ktchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Closet 2 49 490 No 0 1 Yes Yes Yes 2 Bath 70 700 No 0 1 Yes Yes Yes 3 Game Room 238 2380 No 2 1 Yes Yes Yes 4 Closet 36 360 No 0 1 Yes Yes Yes 5 Pantry 36 360 No 0 1 No Yes Yes 6 Hall 30 300 No 0 1 No Yes Yes 7 Bedroom 3 154 1540 No 1 1 1 Yes Yes Yes 8 Bath 90 900 No 0 1 Yes Yes Yes 9 Laundry 90 900 No 1 1 Yes Yes Yes 10 Hall 72 720 No 0 1 No Yes Yes 11 Bedroom 2 216 2160 No 1 1 1 Yes Yes Yes 12 Kitchen 255 2550 Yes 2 1 No Yes Yes 13 Dining 216 2160 No 2 1 Yes Yes Yes 14 Great Room 362 3520 No 2 1 Yes Yes Yes 15 Foyer 64 640 No 0 1 Yes Yes Yes 16 Master Bedroom 350 3500 No 2 1 1 Yes Yes Yes 17 Hall 48 480 No 0 1 Yes Yes Yes 18 Den 143 1430 No 1 1 Yes Yes Yes 19 WIC 2 42 420 No 0 1 No Yes Yes 20 AH 24 240 No 0 1 No Yes Yes 21 Master Bathroom 262 2620 No 1 1 Yes Yes Yes 22 Toilet 30 300 No 0 1 Yes Yes Yes 4122/2019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume 1Gtchen Occupants Bedrooms Infil ID Finished Cooled Heated 23 WIC 1 90 900 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Closet 2 14 It 0 49 ft' — 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 2 17 It 0 70 ft- — 1 0 0 3SIab-On-Grade Edge Insulatio Game Room 16 It 0 238 ft' — 1 0 0 4 Slab -On -Grade Edge Insulatio Closet 3 6 ft 0 36 ft- — 1 0 0 5 Slab -On -Grade Edge Insulatio Pantry i ft 0 36 ft' _ 1 0 0 6Slab-On-Grade Edge Insulatio Hall 3 1 ft 0 30 ft' — 1 0 0 7Slab-On-Grade Edge Insulatio Bedroom 3 11 ft 0 154 ft' __ 1 0 0 8 Slab -On -Grade Edge Insulatio Bath 3 9 ft 0 90 ft' _ 1 0 0 9Slab-On-Grade Edge Insulatio Laundry 9 ft 0 90 ft' _- 1 0 0 10SIab-On-Grade Edge Insulatio Hall 2 1 ft 0 72 ft' — 1 0 0 11SIab-On-Grade Edge Insulatio Bedroom 2 12 ft 0 216 ft' ___ 1 0 0 12SIab-On-Grade Edge Insulatio Iotchen 1 it 0 255 ft' __ 1 0 0 13SIab-On-Grade Edge Insulatio Dining 25 ft 0 216 W — 1 0 0 14SIab-On-Grade Edge Insulatio Great Room 16 It 0 352 ft' _- 1 0 0 15SIab-On-Grade Edge Insulatio Foyer 8 It 0 64 W 1 0 0 16SIab-On-Grade Edge Insulatio Master Bedroom 33 It 0 350 ft' _- 1 0 0 17SIab-On-Grade Edge Insulatio Hall 1 2 it 0 48 ft' — 1 0 0 18SIab-On-Grade Edge Insulatio Den 20 ft 0 143 ft' _- 1 0 0 19SIab-On-Grade Edge Insulatio WIC 2 1 it 0 42 ft' — 1 0 0 20SIab-On-Grade Edge Insulatio AH 1 ft 0 24 ft' _- 1 0 0 21SIab-On-Grade Edge Insulatio Master Bathroom 44 ft 0 262 ft' __ 1 0 0 2251ab-On-Grade Edge Insulatio Toilet 6 ft 0 30 ft' __ 1 0 0 23SIab-On-Grade Edge Insulatio WIC 1 18 It 0 90 ft' _ 1 0 0 4/22/2019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - Fla Res2017 FBC 6th Edition (2017) Compliant Softvrare Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPURT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3307 ft' 0 ft' Medium N 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2957 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Unvented) Closet 2 20 Blown 49 ft' 0.1 Wood 2 Under Attic (Unvented) Bath 2 20 Blown 70 ft' 0.1 Wood 3 Under Attic (Unvented) Game Room 20 Blown 238 ft' 0.1 Wood 4 Under Attic (Unvented) Closet 3 20 Blown 36 ft' 0.1 Wood 5 Under Attic (Unvented) Pantry 20 Blown 36 ft' 0.1 Wood 6 Under Attic (Unvented) Hall 3 20 Blown 30 ft' 0.1 Wood 7 Under Attic (Unvented) Bedroom 3 20 Blown 154 ft' 0.1 Wood 8 Under Attic (Unvented) Bath 3 20 Blown 90 ft' 0.1 Wood 9 Under Attic (Unvented) Laundry 20 Blown 90 ft' 0.1 Wood 10 Under Attic (Unvented) Hall 2 20 Blown 72 ft' 0.1 Wood _ 11 Under Attic (Unvented) Bedroom 2 20 Blown 216 ft' 0.1 Wood _ 12 Under Attic (Unvented) Kitchen 20 Blown 255 112 0.1 Wood 13 Under Attic (Unvented) Dining 20 Blown 216 ft' 0.1 Wood 14 Under Attic (Unvented) Great Room 20 Blown 352 ft' 0.1 Wood 15 Under Attic (Unvented) Foyer 20 Blown 64 ft' 0.1 Wood _ 16 Under Attic (Unvented) Master Bedroom 20 Blown 350 ft' 0.1 Wood 17 Under Attic (Unvented) Hall 1 20 Blown 48 ft' 0.1 Wood 18 Under Attic (Unvented) Den 20 Blown 143 ft' 0.1 Wood 19 Under Attic (Unvented) WIC 2 20 Blown 42 ft' 0.1 Wood 20 Under Attic (Unvented) AH 20 Blown 24 ft' 0.1 Wood _ 21 Under Attic (Unvented) Master Bathroom 20 Blown 262 ft' 0.1 Wood 22 Under Attic (Unvented) Toilet 20 Blown 30 ft' 0.1 Wood 23 Under Attic (Unvented) WIC 1 20 Blown 90 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Ornt Space In Wall Type _ 1 N Exterior Concrete Block - Ext Insul Closet 2 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 _ 2 E Exterior Concrete Block - Ext Insul Closet 2 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 _ 3 N Exterior Concrete Block - Ext Insul Bath 2 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 _ 4 W Exterior Concrete Block - Ext Insul Bath 2 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 _ 5 E Exterior Concrete Block - Ext Ins9lame Room 4.1 14 0 10 0 140.0 ft' 0 0 0.6 0 6 W Exterior Concrete Block - Ext InsMme Room 4.1 2 0 10 0 20.0 ft' 0 0 0.6 0 4/22/2019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 7 E Exterior Concrete Block - Ext Insul Closet 3 4.1 6 0 10 0 60.0 ft' 0 0 0.6 0 _ 8 E Exterior Concrete Block - Ext InsiBedroom 3 4.1 11 0 10 0 110.0 ft' 0 0 0.6 0 _ 9 E Exterior Concrete Block - Ext Insul Bath 3 4.1 9 0 10 0 90.0 R' 0 0 0.6 0 _ 10 E Exterior Concrete Block - Ext Insul Laundry 4.1 9 0 10 0 90.0 ft' 0 0 0.6 0 _ 11 S Exterior Concrete Block - Ext Insdbedroom 2 4.1 8 0 10 0 80.0 ft' 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext InsLBedroom 2 4.1 4 0 10 0 40.0 ft' 0 0 0.6 0 _ 13 N Exterior Concrete Block - Ext Insul Dining 4.1 12 0 10 0 120.0 ft' 0 0 0.6 0 _ 14 W Exterior Concrete Block - Ext Insul Dining 4.1 13 0 10 0 130.0 ft' 0 0 0.6 0 _ 15 N Exterior Concrete Block - Ext Insgreat Room 4.1 16 0 10 0 160.0 ft' 0 0 0.6 0 _ 16 S Exterior Concrete Block - Ext Insul Foyer 4.1 8 0 10 0 80.0 ft' 0 0 0.6 0 _ 17 N Exterior Concrete Block - Ext InUbster Bedro 4.1 15 0 10 0 150.0 ft' 0 0 0.6 0 _ 18 W Exterior Concrete Block - Ext Int76ster Bedro 4.1 18 0 10 0 180.0 ft' 0 0 0.6 0 _ 19 E Exterior Concrete Block - Ext Insul Hall 1 4A 2 0 10 0 20.0 ft' 0 0 0.6 0 _ 20 E Exterior Concrete Block - Ext Insul Den 4.1 13 0 10 0 130.0 ft' 0 0 0.6 0 _ 21 S Exterior Concrete Block - Ext Insul Den 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 _ 22 E Exterior Concrete Block - Ext InMAster Bathro 4.1 11 0 10 0 110.0 ft' 0 0 0.6 0 _ 23 S Exterior Concrete Block - Ext InUAster Balhro 4.1 16 0 10 0 160.0 ft' 0 0 0.6 0 _ 24 W Exterior Concrete Block - Ext InUAster Balhro 4.1 17 0 10 0 170.0 ft' 0 0 0.6 0 _ 25 N Exterior Concrete Block - Ext Insul Toilet 4.1 2 0 10 0 20.0 ft' 0 0 0.6 0 26 W Exterior Concrete Block - Ext Insul Toilet 4.1 4 0 10 0 40.0 ft' 0 0 0.6 0 27 N Exterior Concrete Block - Ext Insul WIC 1 4.1 1 0 10 0 10.0 ft' 0 0 0.6 0 28 W Exterior Concrete Block - Ext Insul WIC 1 4.1 17 0 10 0 170.0 ft' 0 0 0.6 0 29 N Garage Frame - Wood Laundry 11 10 10 100.0 ft' 0 0.25 0.600000 0 30 N Garage Frame - Wood Hall 2 11 4 10 40.0 ft' 0 0.25 0.600000 0 31 N Garage Frame - Wood Bedroom 2 11 10 10 100.0 ft' 0 0.25 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Foyer None .39 6 8 48 ft' WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 4 Metal Low-E Double Yes 0.65 0.3 N 22.7 ft' 2 It 0 in 1 ft 4 in None None 2 E 5 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None 3 E 8 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None 4 E 9 Metal Low-E Double Yes 0.65 0.25 N 6.0 R' 2 ft 0 in 1 R 4 in None None 5 E 10 Metal Low-E Double Yes 0.65 0.25 N 6.0 ft' 2 ft 0 In 1 It 4 in None None 6 S 11 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 15 ft 0 in 1 ft 4 in None None _ 7 N 13 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft' 9 ft 0 in 1 ft 4 in None None 8 W 14 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft' 9 ft 0 in 1 ft 4 in None None 9 N 15 Metal Low-E Double Yes 0.65 0.3 N 96.0 ft' 22 ft 0 in 1 ft 41n None None 412212019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - Fla Res2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 10 11 _ 12 13 14 15 S 16 Metal Low-E Double Yes N 17 Metal Low-E Double Yes W 18 Metal Low-E Double Yes S 21 Metal Low-E Double Yes S 23 None Glazed Block No W 24 Metal Low-E Double Yes 0.65 0.25 N 9.0 R' 22 ft 0 in 1 ft 4In 0.65 0.3 N 48.0 ft' 20 It 0 In 1 ft 4 in 0.65 0.25 N 12.3 ft' 2 ft 0 in 1 ft 4 in 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in 0.6 0.6 N 30.3 ft' 2 ft 0 in 1 It 4 in 0.65 0.25 N 15.0 ft' 2 It 0In 1 ft 4 in None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 748 ft' 748 ft' 24 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3449.8 189.39 356.18 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitf Split SEER: 16 46 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS / V # — Supply — — Return — Air CFM 25 CFM25 Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 135 ft' Attic 15 ft' Default Leakage Attic (Default) (Default) 1 1 4/22/2019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - Fla Res2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programablje Thermostat: Y Ceiling Fans: HeNov ating [X] Jan [Xl Feb ((�� [X] Mar r [ [ Mayf ]J Jun [[ ]] [X] Jul ] 4X1 Aug j 4X1 Sep [`x�j� Oct Nov Dec Dec Venting [[ ]1 Jan I[ 1] Feb [[X]] Mar [X APf I May I Jun lXl [( ]] Jul I ] Aug (1 Sep l^l Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WO) AM 78 78 78 78 78 78 78 78 s0 80 80 80 PM 80 s0 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 65 66 66 66 66 68 68 68 68 68 68 68 PM 66 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 66 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(S lbs/sq.ft. 0 ft- 0 ft 0.3 Closet 2 Default(S lbs/sq.ft. ft' ft 0.3 Bath 2 Default(B lbs/sq.ft. ft' ft 0.3 Game Room Default(8 lbs/sq.ft. ft' ft 0.3 Closet 3 Default(8 lbs/sq.ft. ft' ft 0.3 Pantry Default(8 lbs/sq.ft. ft' ft 0.3 Hall Default(8 lbs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 lbs/sq.ft. ft' ft 0.3 Laundry Default(8 lbs/sq.ft. ft' ft 0.3 Hall Default(S lbs/sq.ft. ft' ft 0.3 Bedroom 2 Default(S lbs/sq.ft. ft' ft 0.3 Ktchen Default(8 lbs/sq.ft. ft' ft 0.3 Dining Default(8 lbs/sq.ft. ft' ft 0.3 Great Room Default(8 lbs/sq.ft. ft' ft 0.3 Foyer Default(S lbs/sq.ft. ft' ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft' ft 0.3 Hall Default(8 lbs/sq.ft. ft' ft 0.3 Den Default(8 lbs/sq.ft. ft' ft 0.3 WIC 2 Default(8 lbs/sq.ft. ft' ft 0.3 AH Default(8 lbs/sq.ft. ft' ft 0.3 Master Bathroom Default(8 lbs/sq.ft. ft' ft 0.3 Toilet Default(8 lbsis.ft. ft' ft 0.3 WIC 1 4/22/2019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017, - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Johnson Residence Builder Name: Street: XXX Pinecone Lane Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34946 Permit Number: Owner: Johnson Residence Jurisdiction: St. Lucie County W x Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be Insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (Including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned spare shall be sealed. Batts In narrow cavities shall be out to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fxtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pining and yviring Showeritub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor ordrywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire sprinkler cover dates and walls or cellinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/22/2019 10:48 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ttEGELV�E]i MAY z 12aj9 kirmltting Department ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CAS` dd0 County ESTIMATED ENERGY PERFORMANCE INDEX" = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 46.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2957 d) Room uniVPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.646 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.302 14. Heating system: Capacity 34.0 c) Area 7c. 365.2 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1082. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. T is home has cc lied 'th the Florida Building Code, Energy Conservation, throug the above energy res which will be inst Ile (or exceeded) in this home before final inspectioLhv a new EPL will be complet a on installed code compliant features.Rf,irP- 4 nmtp. !�/ Address of New Home: XXX Pinecone Lane CitylFL Zip: Fort Pierce, FL 34945 4/22/2019 10:48:13 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Date: wrightsoft• Entire House Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 77246&6799 Email: quiclmalcs@aoLcom Promect Information For. Johnson Residence SCANNED _ XXX Pinecone Lane, Fort Pierce, FL 34945 BY Notes: St. Lucie County Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 35385 Btuh Ducts 6471 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 41856 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 2957 2957 Volume (fN) 29570 29570 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 158 79 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 12.3 kW 41858 Btuh 25 OF 1533 cfm 0.037 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 29070 Btuh Ducts 4419 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data in Rate/swing multiplier 0.95 Equipment sensible load 31814 Stun Latent Cooling Equipment Load Sizing Structure 6494 Btuh Ducts 3485 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 9979 Btuh Equipment Total Load (Sen+Lat) 41793 Btuh Req. total capacity at 0.70 SHR 3.8 ton Cooling Equipment Summary Make Trans Trade TRANE Cond 4TTR6049J1 Coil TEM6AOD60H51++TDR AHRI ref 8630141 Efficiency 13.5 EER, 16 SEER Sensible cooling 32200 Btuh Latent cooling 13800 Btuh Total cooling 46000 Btuh Actual air flow 1533 cfm Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + fl- wri9h[soft^ 2019-Apr-1422:33:49 .��-.. -- RightSuite® Universal 201919.0.01 RSU08101 Page 1 ACC %...Documents\ftghtsoft WAC\lohnson Residence.rup Calc=MJ8 Front Doorfaces: S O Z .t :j [n000t�00000.00000000�0 NN N N �O 00 N OOOtV� tIPVV mmN r, m P P _ pOp A OO OO OOOOOOOOOOO OOOOObm ' rym I1��O OOOe-P blf� L Jm O a N r = O O K � b N � P p ` e O1N+OrnCm m �mmONmr AOI pN O OOOmP OlbW b mN[On Nt7.N �pN PPfOm N wow 1 m � $O MN N rCTS oO U V t Bm rON OIrNPmm P N mr 0mb Nt+NI � N m 0 �(t m O O O N � N(� of j(S � ry�NfOO���YSN Nm fO V pa;�(V r° P 'o r xo 1ILL O �_ ci v'6 (•m]V{l Oim �(h,WN Nc1V'�N��mNG OI OI fO CCCIII N C6 tiom�nn�mm 0 (VHOI OIN QNPN O10101NON, NP QOI.�O 146d �pp p p p p p p p p o p �pp epp p SOlIa InOln InONN 1 NN It Zm q a 0080Ni1�Y'lln CmN"Q ENV r'f'�NOP�1� N r m N N N N N N N � � N IN N x CCC 000. 0 N N. N33333•• O �� a LL m 000 mom000 m o0o m POI r PrrrQQ SiQppr rim csmOOOOOO rr circsrPm. � �" o.=o 00000000000�00000' DOD a`m_ m o ? m rl 2 E a ` E0E0 §EoEoEo. cc EE E 0 4ENNN O�O myoN 0o mC U ❑E 60 d �cN EE m �E V O O o C Q agqCD 9 y y p 0 Q p E o o oo ¢ v n ¢u'i¢KK ma �NmPN - b b PH ld Cml d p p q T 7 � m L N `o to C W 0 (o I 16 � U RW a 3' E 0 W O N n OQ N !O 0 N N CO, O Op U cSm a000 .-oN0000 oo om0000tim No 0 oo�smm o Y N N N E n 2 0c � vo x Eo 000 o,n o�00000000000�m o O v (n N N o V [L O O V E 6 m N N N N m v ¢`oU V co $m V0000000aaoo�000 d r�i o v v N � Lq O N C tiN O O V C 00 O O 00 000 O O 000 O H 000 co O O O a o ¢o Q p 8 0 NNWOIN pQN mOIAHONm,NU Q01�0 , 8m�m��388�8�3�i,8S888�3�Yi�8 - �� R _ QCtN NQNNQ NNN��Q tO�INNN� N C CCCWWNNWNNNN3>j 333 „ �o n o n. o n n n m m 6m n n 0�oooo0000'o oo o.=000o o a`m_ >> n 0 0 ti 2 `w C E E§ E EI E E Ew EEEc� N N N N ry N N tl� o o a O E q U N E 4 E g N N C�!g� O E E dAl A�/,'h dhu AX L° a O N E y Eva °a E u5 O c�o¢<6�¢¢d6o¢¢¢e�'co v _ m� E V Ev N p y d c Q P P Q Q P O n Q P P y o O o p c� OI - �z'av o tttt¢K H�I11I F Q u c W ma v o m a d e fl HQ ULL _ N ���v10 �Nm Qin co co N M ^� mN Q y m � N 6 P a� f, 0 ID a rn'a i.+ N m a Ana WNW Dti OVA r — Pm rtl o m g 2 0 6 N m o o0o%O 3 3 3 v 3 o 0 m3 aD 'o ia-'. +D➢�+➢Do� d?�n'3 a3 m m 3r Dba DDDD 29.1. 2d 3n �m m w O r m °�- � 0003 m000 aoo ao 3 ➢�333 �•�3.33 �'.33�a3 3. m = n a W � � my 0000O�000000000000-0c 0 8108�a.�`8 0000 aw oo aw000 aw �m o (8� m•��FFFFFmmmmm mmmm O fON al aI�NONO�q�0Ou1N ONQNp » m2 v ' O+. fONNON OOoo�tO IOO NN,taO IJ !D !D OtJ O � oD m a m o Yn 6'i000 oo0000000000000 -3' 0 0 m� a _mb°oo0000000000000000 K mo orb, sw � m a o p (NTH N WOO O W O t00 W v O O O O O O O O O O O O O O 0000 m gj n V n 8�j 0 O — �+ O$ 0 0 0 8 0 0 0 "O � m OD m �° o �'i $'i000aooa00000000000 V 3� W OI O o 0 'rn ur a o e om00000000000000000o v w 00 � m m o r m a Wei Wao 10000000000..0.0000 Ea x8 O V o W0 �00�00 � o0 00 � N oea00000000000000000 moL ou m .. E� U) Y 0 rc R W 13 O OOO$O�OOOO OOOOOOONO rj �O NO P OOt1Nn y� gm OOOOSON0OOOOOOOOOO41� O Y N m M N`CS N N ?N n m � 2 E 20 _ 0 0 C m O O O m 0..0...00000000 ... Q O ' N .0 00 m 00.00 O O _p O oO U a0 d'Y L B� O O O O O O O O O OA 0 0 0 0 0 0 0� 0 m Q 00 m Q oo.00 4 00 0 u me io x o00000000000000000mo e c m ' m o 2 v 0 0 `~'E 00OO0000000000000O8. o a" b m n m w Q`o UE rn gininm��!'t`nmm��i min oo�dr`ing 01 CdbdNNNNdN33333� OLL 1-3 �� 0 m000moom000 m oOO o�o� QmnnQnn.Q i�`�rn•$$•'-�m rn-�n�tii.. ?V nnn�nn� d�00000000000o�000cc' �cm_ m ' cs co o 2v ga ii E H EE EE EN EEE 1O o 00 00 000 000� o c a o m a o a N d "v C E 4 EN N 4 N N N N N p g E N N N P d111 iA¢ IA IA'� ❑¢du5 u5 X L' N o O d C y c C .CIP p v a o E@ VOo c c�`'o`vv���.. E NE pryry Ed QQ S Cb E nE EE a Mrs �II��ttK o W ND f0 ���fn0 H¢ FT-��•ULL I �NmQm IO .. m N m Qln a t rn La 0000$gOO0000000000mo 0 vO? 0000�prn00000000a000•mm � o �o xv x Jpj OOOOm-00000000000000101 3^ � N o a 0 o v.0 o 0 o o m N o o O o o 0 m o o o o o Li0 e o e" O O O O 9 9 O O O O O O O O o o o O N o " N �O} Q O O O qO O o N N m NOCN� N �- IN 1N 0 � � O 8 w� o OT T a O S mr m 4 x mm — 0000m�000000a0000 ohm ;e � v N mO � • ' r ^ d O �E 00000a0000000000000.�� o e w 2 sumo S... p 6066C4 O N N Oi OiN fa Q.N O)OI NgpQO)�O r , f ME m 00,.01001[l l()S N�0 �00m 80N1N�In In tp , : , a x'j d Vmce-O ��V���tOO Vm �1A. m N N N N N N N � � C'1 N N N N • N "N' Cd dd.N NN NNppN� 3ppp3�1^3�313���ppp ❑LL p` `!L� t+C1 pCC VWO OC]00('�0000��(71���V01 •. Wm o.=o 00000 000000�00000'' B. `m_ a a j 000 D��O E� '¢QE¢QE 0 DE_D GE g N doh 6u�666 n$ IIdQEAA¢QE LE� dNr m m'S Ev �Y¢QEe4EQ¢E. r¢wE�¢QAE gdAB� o¢QE N E Ev m o c& o v�Zsoa e'v E EEE o a o 0 0 I❑u�, > E v a N'a a G 8 v K II�K�� F- �' IL ma 4l %✓�( rQ I I� 1 1 I I I� I I I IUu. <i _ JJ�Ktl10 O L cn 0 0000000Qoomoo mM0000�o � � No �o g ooNo� rvm O N � Z Ec m O N G N 0 0 `E o00000000o�000ao0omm - O f0 n [O Q N N N N a `o C7 o00000000000000000 �io - q rn o0 0o m oomoo 00 b � 000000000000000000Qo Q o0 Q ooQoo 00 O m Q 2 NQ O K 2 O O O O O O O.00 O O O O O O O O O M1 O oQ O � v f9 , M M " a O O v E O O O O O O O O O O O O O O O O O O N N O e 6 A G m rr 0 pmj a O p CV Nm v cC QV" mm m N O N MCV 0; f xm M -- 8Y30o _ a Q.Ir q 0r!QSmm8����°� Im�IN {VQ NNNNNt�NNN�N N OLL �� MOOOMOOM 000 (�M OOOHm. ' �c� nQnnQrrn$ Q�nrn m noo -rrr .o.- rrrQm and .. o�od000 00000c o.=00000 m� m o Ti 0 a o c 9 2� D'i YS EEmEE,�E E Em EE E'i° 00 o o 0 0 m c o o a E E o 0 0 0 m a 1 $ E Ni` N N v N N (V ® E N N N @ y c O m C C E ,i mam ¢¢ mauE@ c QQvQQ�QQQr���QQ e=io �Q (lll,nI ln(n TITI OE EE o So oo Q m E n °"S N',�oa T22i ¢� K it K KK H u W na & f9 a�KfO rQ ULL. L] �NMQYI f0 f0 ' Q' m .m �? m �a Q lti 44 r 'n n.�Gl�� $l Do c�cmmm gm m o �I �I��I � ]]M II 333 3 'mN 3y'O d dM Smo5501• RxxOSNN � N00 0000QQ00 3033 Qj R2 6 N w o o me ,QD s 2d ma a0000+OO000000000,0�0 o wm oo oo o w o o w o o wit O � FFFEi N N N N N N'N N N. x N NNNIJ�pp�i ii Aiiai�wa v fTN OJN O(�ONo (O (O (O N,N 6 N(p fOON pOp+IO pv'i 00 +(O aOfJ iifOOJ(OWiW10 a +y N N �n �ii000000000000000000 N N (P O 0 e N 3� o � � z y � O o O NO O O O O O O O O OO O O O O O O O — x 0 3 s� m+n i m o � �'om mmaoo a oo g o�o0000000000000000o Wr 0 a o� o N N N 0 0 0 0 0 0 0 ...... 08.8 N O O N 6i O N �'m oo0o$000000000000� — x 0o o_ ` am' x N A ..1000$00000 w O K2 moo Om w o o a o o�o 0 at0 p_�pw w Om N�oO i N 00 ON N O O I O.00008.000000000NOV L� 3 L aC®C ((A C fD 0 N Li mom w Q A.. O a ccArr om, TOI xt 11 A$xl Q � q n� o < m D I�I �I I °o O °o S 13o GI G) G1 h h N+aaa+++�aaa+Aa�aa+� Nmy iyyi�^,oWf�(D(yyD DD Yp�Yp�1 Yy�Do D xW 0(O �3 n aNm m O N d _, - m u o 3 m x m m �3-5n5 o. y N r N N 3 p N N N A N N y N N 3 V o00000 00 o yy S boo. m 333 y -3.33 9,33 �,3 3 2 n ER m 'm = n 5 o DO �C a Q 2a dQa p0000�0000a0000000�o 000 w 0000 oouo o �o w FFFFF N N N N N N mmm...7 O `a N N NNN OIa Om+iiA�iAiim A. d 0-il O �1p EA Oi Oi tJS1.)S rn.4�cli SOi Oi S<nmNS 1pON mN(O(J� (al�N tO NNtaJ N(p pO+fO pNpN(O O ^WJ.+OO �(pamiiimOV fOi �yOj (p O oD e N S tJ tp � NfNT O O O O O O O O O O O O O O g O O O N d N 3 �. W N O O O YN^ N 1 p� m � � 0 m N O O O O O O O O O O O O O O O O O A m p�j k ^ p so 0 + W mW m m N p [OTC o ON 10 + + O- O O f0 O N V W W O O O O O O O O O O O O O O O O O OI d x� O_ �n 5d� 1.N1 i J a Om� NO m N N W m O O m 8WA O O m m O O O O O O O O O O O O O O WO O O ' a ae o �g'0000o�000mo00oo000 m2 ^ � o a' mA00000mO00fO W0000.000 � K OtO .T O N � y O �a m�$�'oo (o orn $,° N+00000 aooaa�0000000 �w w 00_ — �m m�o�oo � � m a ooa00000000 o0 0� 0�0000omo Ci 3 ON M N rt O y O R N Ti=r lY r► d � p N T 7 Q m '0000Q0000000000000�0 �n $ o0 00 � oo�oo 00 o 0 (g mpy oa0000000000000aoom � - N �o mQ ooQoo 00 L Jm m n N N N O q � v W 2 , C O 2 fV x O O O O� O O O O O O O O O O O O O Q N O C N 0 0 `El 000ON00000000 o o a o ORE? o m M O O O O O O O O O O O n 0 O)O O m O O 2 O $ 00 O O O Q O 0 n N O� Q Q Q _ O NO LO q� Jm mp �mpO OO OOOOOOOO �O t�OOVyt�V t� NOO mm V� 00�01� Nm E N Vt0 m N NOl Q �N c m W� m i p % _ o000000000000$oNoo$�' ae �m _V 0 0 �E m0000000000000Nooc,�cZ �i N O g VNI N m n N Q m if i�S m E 0 'CINTWNQQ,N D10101 V10'Nm ��W�CI d c c�cyyNNNNNNN33��3�� � ' c� LL 'mo o�ooe 0000����000 mo o� � 0-=00o+0on.'o.-ononon odC5 do`o 00 ' me av oa O O � C j F D D E E'" EE'. YS EE E`m' E E E 2S C N O a 4 'N CE o o o o qo a o 0 0 0 EN,/,N NNY(VNNmpgE��NS5�N�nnN_E pj q E3�vv CYcdiA�iA¢in in ,A �O dd4 Q.A L^E Ea c9c"am o ¢ vv�vv�eeen.-�.-QQQ.-Ni a �o €� _ v a �' �' �' �`QULL E of EE o w s v -� E E 'So ,ri�a- m o a t5 K 'ui�tt¢ r o w ma - �NOIQN m m ^ ` Qm w Du - T0�047NipN ,II�II u�N a o„ m ... , o o O �ONyy o O 0 D v 000 O 3 3 3 3 C'O+AAA++JLOdNdpl rn o �y"'N, d ry 0 a O 3'm ry x A3 d- 3 �m^d In = m N E nDo �_� pp �"�' off' �SN"NP SHOWN 'S� _ �a m N gg N N yq e�3333 3 n N 3 o m m .33f�.k 0 tS 2 6 y y 0 O v O mC � a+v oo 000�00000a000000�o 0000 aw Aw nL i3 w oo wa000 '� --0oo N`a ��FFFFFNNNNN N'ryN N.7707. O 3 � � G O+�DNN�NOONo fO fO tO N01 ,4a1 N1010 � p0N SV �00 mfD �Q��ii(O0'JJ IOi.W+(a (p � H oD m m 'a 3E N � (AJ (AJ 00000000(TO 00000000 3.-. O O � O(J OOOOOOOO OIO NOOOa000 O� x O 2 O O X O :k 5� O O O O (T N 4 V 0 0 0 O O O O O fNJ 0 0 0 0 0 0 0 0 d d O O_ v O � u a i�m'aoo o0 ow a olio 0000'00000000�0000 O a � a rn N N O O l rn 0 o N O N O O O O O O 000000000000 - x a0 S N N � y o p m0' ONI (T"moo 'rnJ oo °J' o^ 000o0000000aoaa000 r m^O O 5a ss.J o TST 02 82!20o urns o0 0o ' ornJo 00000000000000000 iii j + Wrightsoft• Right-JO Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickmalcs@aol.com 1 Room name AH Master Bathroom 2 Exposed wall 0 ft 44.0 ft 3 Room height 10.0 ft heat/cool %0 It heat/cool 4 Room dimensions 4.0 x 6.0 ft 1.0 x 262.0 it 5 Room area 24.0 ft- 262.0 fN - Ty Construction U-value Or I HTM I Area (fY) I Load I Area (ft°) Load number (BtuNfY-°F - (BtuNft') or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cool I Gross NIP/S j Heat Cool Gross NIP/S Heat I Cool 6 13A-46cs 0.143 n 4.00 2.19 0 0 0 0 0 ` 0 0 0 I-G 106m 1.390 n 38.92 20.03 0 0 0 0 0 0 0 0 4A5-2om 0,770 - n 21.56 19.31 0 0 0 0 0 0 0 0 L��G 4A5-2omd - 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 11 0.143 a 4.00 2.19 0 0 0 0 110 110 440 241 Tn13A400s 4A5-2om 0.770 a 21.56 43.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0 13AAoos _ 0143 s 4.00 2.19 0 0 0 0 160 130 520 284 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 G 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 a 15.08 0 0 0 0 0 0 0 7A-3gnsn 0.600. a 16.80 10.92 15.34 0 0 0 0 30 30 5-0 6 450 1100 0.390 s 40.92 10.34 0 0 0 0 D 0 .0 0 0.143 w 4.00 2.19 0 0 0 0 170 155 621 339 100.m 1.390 w 38.92 38.61 0 0 0 0 0 0 0 0 N13A-4ocs 4A5.2om 0.770 w 21.56 42.10 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.10 0 0 0 0 15 1 323 677 4A5.2om 0.770 w 21.56 19.31 0 0 0 0 0 0 0 0 C _ 16X19-0ad 0.408 _ - 1.59 1.37. 24 24 38 33 262 262 415 358 F 22A-tol 0.989 27.69 0.00 24 0 0 0 262 44 1218 0 61 c)AFD excursion -1 122 Envelope loss/gain 38 31j 40461 2477 12 a) Infiftration 0 0 803 215 b) Roomvemilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 38 31 4949 2922 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 38 31 0 0 14 Subtotal 0 0 4849 2922 15 Dud loads 184 15% 0 0 18% 15% 887 444 5210I 33541 ATotair required (cfm) I I 01 0 I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � -01*- wr�gn[soit' 2019-Apr.1422:33,49 •- RightSufte® Universal 201919.0.01 RSU08101 Page 11 ._DocumentstWdghtsoft HVACUOhnson Resldence.rup Calc=MJS Front Door faces: S +wrightsoft• Right -A) Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quiclmalcs@aol.com 1 Room name Toilet WIC 1 2 Exposed wall 6.0 It 18.0 ft 3 Room height 10.0 It heaVcool 10.0 ft heat/cool 4 Room dimensions 1.0 x 30.0 ft 1.0 x 90.0 It 5 Room area 30.0 ft' 90.0 W -- Ty Construction U-value Or I. HTM I Area (ft') I Load I Area (ft2) Load number (Btuh/fl'-°F (Btuh/ft= or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross IJ/P/S j Heat Coot Gross WP/S Heal Cool 6 Vh13A-4ocs 0,143 n 4.00 2.19 20 20 80 44 10 10 40 22 100-M 1.390 n 38.92 20.03 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 4A5.2omd 0.770 n 21.56 19.31 0 0 0- 0 0 0 0 0 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 4A5-2om 0.770 a 21.56 43.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 a 21.56 45.10 0 0 0 0 0 0 0 0 G 13A-40cs 0.143 s 4.00 2A9 0 0 0 0 0 0 -0 0 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 7A-3gnsn 0,600 s 16.80 15.08 0 0 0 0 0 0 0 0 1100 0.390 s 10.92 10.34 0 0 0- 0 0 0 0 0 W 13A-4ocs 0 .143 w 4.00 2.19 40 40 16 80 170 170 681 372 0. 10 m 1 .390 w 3.92 38.61 61 0 0 a 0 0 0 0 0 0 4A5-2om 0,770 w 21.56 42.10 0 0 0 0 0 0 0 0 05-2om 0.770 w 21.56 45.10 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21.56 19.31 0 0 0 0 0 0 0_ 0 C M19-Oad 0.408 - _ 1.59 1.37 30 30 48 41 90 _ 90 - 143 123 F 22A-tpl 0.939 27.69 0.00 30 6 166 0 90 18 498 0 6 c) AED excursion -9 -27 Envelop. loss/gain 454 163 1362 490 12 a) Infiltration 109 29 328 88 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 563 193 16901 578 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 563 193 1690 578 15 Duct loads 18% 15% 1031 29 18% 15% 309 88 624I 210I 22 197733 63D A65 i requiredl(cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t - =lgtitso�fL� 2019-APf-1422:33:49 RlghtSulte® Universal 2019 19.0.01 RSU08101 Page 12 ...DocumentslWnghtsoft HVACUohnson Residence.rup Can =MJ8 Front Door faces:S Sr �J s �cn k 1.1 V t M J LL N cX L iXZ 0 LL D D D O p ON N N N p Cxxx=rE p. 6 ccc2 I.i co U-i U)iLO V c) O ON NLO p t j r O N O 0 0 0 0 p OLN NNN0 cxxxxrE = 0 0 0 m co W W N N N O N O Y ` O-VW I�ML�OM rf�rrYLU LU Sy Syr V L- .r N UN N N N N tl1 N N N f!1 N fA N N N N N N N w � 000000000000000000000 ui0L6660L6-Ai L6L6L6vs666660666 J �m � ��--�0 ��� cr-`rM r j M W N V' M LO N 0 r M r- N C O M W W W 0 n r li-i 600 (600' Oh MLn Wr Wr C LNaiN V N0 M N IX ❑� X X X X X X X X X X X X X X X X X X X X LL LL LL_ LL_ LL LLLL LL LL LLLLLLLLLL LL LLLLLL LL_ LL LL »»»>>5ii»»>»»> X.9 C o ox Oxx o�( ox O O oxx oxx ox oxx o o�( O ox ox ox o ox Ox Ox x v tJ O O O O O O O O O O O O O O O O L� 0 0 0 E c O O O O O O O O O O O O O O O o 0 0 0 0 0 ru -gITwv f0 ._ co coLrivr-adcor�p- OD(Dwl—N r- 1'- O M O W N O m g L n W m W W r N N q C m Ln r W W O M m W r-r p v m m W N W r LL mLL N CN MN N CO CO M CO N CO MMNNMMCl) M MM o 6 0 0 0 0 0 6 6 0 0 6 6 f. 6 6 f 7 0 0 0 0 f N I N N r V L f) m m N m R W W M O O t U m E m Co L O 1� N r I� W v'T m m v (0 W p p r Cl) r r r r r U u N I 1A 2 U r r WmW W WmvmvWl�nNr�WcvW Wmo mMhW rr�WOmI�W WrOM W W W W mW I N m W L O W W m L O O r r r L () L o r r W m r pLt N r r r r N M r M N N M r W M M r Q m L L L U L L L U L U U U U U L L L U L L L a LU E E a S Z p o o o m m m E E ry M ry a$ E C C L v Z v ry c T A 0 m m a o N Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st7 Peak AVF 246 250 0.261 458 10.0 0 x 0 VinlFlx st3 st3 Peak AVF 428 429 0.261 546 12.0 0 x 0 VinlFlx st5 Peak AVF 154 173 0.249 496 8.0 0 x 0 VinlFlx st4 st4 Peak AVF 245 373 0.249 474 12.0 0 x 0 VinlFix st1 st1 Peak AVF 463 615 0.249 576 14.0 0 x 0 VinlFlx st6 Peak AVF 338 243 0.297 430 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 643 489 0.297 601 14.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 0x0 1533 1533 0 0 0 0 0x 0 VIFx � Wrightsof - 2019-Apr-1422:33:51 C }� .._..�..� Rig Universai 201919.0,01 RSU08101 Page M`�!i...pocuments\Mghtscft HVACUohnson Residence.rup Calc=MJ8 Front Doorfaces: S