Loading...
HomeMy WebLinkAboutMOBILE H OME INSPECTION REPORTSt Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 SCANNED C N ED Mobile Home Inspection Report St. Lucie County All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone 11 certified. Owner. Y ! 1 t L" ELD&C01 \ Date: (Print or type) , Address: rtwno a yr Year/ Manufacturer 19 ag I AAF R I Z Serial / t Width Length_ Single C = In Compliance N = Not in Compliance t 5P11541 LME _ FAIRWAYS 1400, �as�a HUD Plate # a Double V/ Wind Zone Fire Safety / Electrical e_ f. Smoke Detector: Installed_V00- Missing 2. Electrical System Checked: Exposed Wiring _Other �L 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other _ 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ —C 5. Electrical Ground: Chassis Main Panel Gas Pipe RECEIVED h^AY 2 2 2019 -rip _a ancy,Permltting REVIEWED FOR Reviud 3/9105 Page 1 of CODE COMPLIANCE ST. L.UCIE COUNTY BOCC Construction C 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable 3. Egress windows: Missing Inoperable G 4. Windows: Broken Glass Inoperable _C 5. screens: Missing Damaged_ C_ 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing _ Loose _ Damaged_ 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other S_ 9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof 10. Vertical tie -down straps: Missing _ Short _ Damaged_ _C- 11. Structural modifications since manufactured: YES_ Nov —12. Walls: Structurally Unsound —Loose —Weather tight Plumbing 1. Trap: Missing Not connected Other _ 2. Plumbing fixtures: Missing _ Not installed _ Not Vented 3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed Other -jC- 3. Thermostat: Missing Inoperable 4. Air registers: Missing Inoperable C 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 (ram 6. Gas furnace Water heater vent: Missing Loose G 7. Return Air: To Furnace To A/C From rooms s_8. Range: Vent Hood C 9. Gas Valve: Accessible Installed improperly _ 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? 2. Will a remodeling permit be required? YES NOw�/_ YES NO—%t/-- The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: '01119 L q Q Inspected By: J . �, License # L J U `�YSV�11 S/gr, Nra requlmd2 CPhone Number:( - 3) E I Page 3 of 3 STEVEN G. WOOD, P.E. FL LICENSE 84398 950 SULTAN DR TORT ST LUCIE, FL