HomeMy WebLinkAboutMOBILE H OME INSPECTION REPORTSt Lucie County Building & Zoning
2300 Virginia Avenue
Ft Pierce. FL 34982
SCANNED
C N ED
Mobile Home Inspection Report St. Lucie County
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone 11 certified.
Owner. Y ! 1 t L" ELD&C01 \ Date:
(Print or type) ,
Address:
rtwno a yr
Year/ Manufacturer 19 ag I AAF R I Z Serial
/ t
Width Length_ Single
C = In Compliance N = Not in Compliance
t 5P11541 LME
_ FAIRWAYS 1400,
�as�a
HUD Plate # a
Double V/ Wind Zone
Fire Safety / Electrical
e_ f. Smoke Detector: Installed_V00- Missing
2. Electrical System Checked: Exposed Wiring _Other
�L 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_
Unplugged Opening Other
_ 4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire_
GFCI receptacles not where required_
—C 5. Electrical Ground: Chassis Main Panel Gas Pipe RECEIVED
h^AY 2 2 2019
-rip _a ancy,Permltting
REVIEWED FOR
Reviud 3/9105 Page 1 of CODE COMPLIANCE
ST. L.UCIE COUNTY
BOCC
Construction
C 1. Exit Doors Operable: Front Back Other
2. Exit Door Locks: Missing Inoperable
3. Egress windows: Missing Inoperable
G 4. Windows: Broken Glass Inoperable
_C 5. screens: Missing Damaged_
C_ 6. Floor System: Joist Decking Area Damaged
7. Interior Paneling: Missing _ Loose _ Damaged_
8. Rodent Proofing: Bottom Board _ Pipe openings _ Other
S_ 9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof
10. Vertical tie -down straps: Missing _ Short _ Damaged_
_C- 11. Structural modifications since manufactured: YES_ Nov
—12. Walls: Structurally Unsound —Loose —Weather tight
Plumbing
1. Trap: Missing Not connected Other
_ 2. Plumbing fixtures: Missing _ Not installed _ Not Vented
3. Relief Valve: Missing Inoperable Other
4. Drain Waste and Venting Piping: Missing Not supported_
Clean outs _ Use of fittings _ Not capped_
Heating and Air Conditioning
1. Heating Appliances: Missing Not Connected Other
2. Deleted Heating/AC system: Not installed Other
-jC- 3. Thermostat: Missing Inoperable
4. Air registers: Missing Inoperable
C 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
(ram 6. Gas furnace Water heater vent: Missing Loose
G 7. Return Air: To Furnace To A/C From rooms
s_8. Range: Vent Hood
C 9. Gas Valve: Accessible Installed improperly
_ 10. Gas lines: Not capped Not supported Kinked
Not bonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated?
2. Will a remodeling permit be required? YES NOw�/_
YES NO—%t/--
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected: '01119
L q Q
Inspected By: J . �, License # L J U `�YSV�11
S/gr, Nra requlmd2 CPhone Number:( - 3) E I
Page 3 of 3 STEVEN G. WOOD, P.E.
FL LICENSE 84398
950 SULTAN DR
TORT ST LUCIE, FL