HomeMy WebLinkAboutINSPECTION CARDInspection Card
Permit # : 22050855
Online address:
SCANNED
Lucie St. L County
http:ltww .stlucieco.org/planning/permitfing.htm
Quick Links:
Permit Status Lookup
Online Building Inspection System
Page 1 of 3
Permit# -
-SLC-22050855 —
— Confirmation
Status VOI
Issued:
7/2/2002
Type:
BUILDING (MISCELLANEOUS)
Job Location:
6439 Peterson Rd
City:
Fort Pierce
Jurisdiction:
ST LUCIE COUNTY
Parcel:
2313-122-0004-000/0
Subdivision:
Lot: Block:
Flood:
X
Elev:
Flood Map: 280F
Set backs:
Left: 175.72
Right:
26.80 Front: 40.00 Rear: 69.98
Job Description:
Construct Front Covered Porch & Add Laundry Room On Rear Of House
Property Owner David & Leitha Senior
6399 Peterson Rd / Ft Pierce Fort Pierce, FL
SUB -PERMITS
Permit No Status Permit Type Cert # DBA Owner/Builder
22060094 Void ROOF - FIBERGLASS SHINGLE
22060092 Void ELECTRIC- RESIDENTIAL
22060093 Void PLUMBING - RESIDENTIAL
Go to htto://codeinspectionRublic.stiucieco.cov to schedule online. For the Automated inspection system call (866) 284-1280.
All inspections requested prior to 9:00 PM will be scheduled for the next business day. Inspection requests between 9:00 PM
Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you require any assistance please contact the
Building Department at (772) 462-1574. YOU ARE REQUIRED TO REQUEST INSPECTIONS IN THE ORDER
THEY ARE LISTED BELOW UNDER DESCRIPTION.
Inspection Notes:
Permit # Code Description
22050855 128 BOND BEAM
1. ALL OPENINGS MUST HAVE LINTEL AT TOP PER
OLEAST 25" & ALL VERTICAL STEEL MUST END IN
WINDOW SIZES HAVE CHANGED FROM 94
22050855 105 FORM BOARD SURVEY -
OFFICE
JO-ANN (LEGACY INSPECTION)
Priori Schad. Date Res Description Inspector Insp. Date
0 8/28/2002 81 Disapproved 8/28/2002
R OPLAN 2. ALL HORIZONTAL REBAR MUST OVERLAP AT
OTHE BOND BEAM WITH A 10 " HOOK 5. PLAN OREVISION -
OTO 6'3 (LEGACY INSPECTION)
1 7/25/2002 90 Approved 7/25/2002
Report prepared on 4/11/2019 12:03:21 PM
Inspection Card
Permit # : 22050855
Online address:
http:/Awvvri.stlucieco.org/planning/permitUng.htm
Quick Links:
Permit Status Lookup
Online Building Inspection System
22050855 115 SLAB 2 7/31/2002
81 Disapproved
AUTOMATED RESULT 08:21:53 31 JUL 2002 (LEGACY INSPECTION)
22050855 115 SLAB 2 8/14/2002
90 Approved Scott Attey
AUTOMATED RESULT 10:44:36 14 AUG 2002 (LEGACY INSPECTION)
Disapproved-
22050855 115 SLAB 2 8/8/2002
82 Reinspect Fee
Required
DOWELS STILL NOT EXPDXIED INTO EXISTING SLAB OIN LAUNDRY
ROOM AS PER DETAIL
TO FAILED INSP 08:21:53 31 JUL 2002 (LEGACY INSPECTION)
22050855 121 TERMITE SPRAY 2 7/31/2002
81 Disapproved
AUTOMATED RESULT 08:22:23 31 JUL 2002 (LEGACY INSPECTION)
22050855 121 TERMITE SPRAY 2 8/8/2002
90 Approved
RCVD FAXED TERMITE CERT FOR LAUNDRY ROOM 11LAID ON GEORGE BELLER'S DESK
TO FAILED INSP 08:22:23 31 JUL 2002 (LEGACY INSPECTION) "
7/3112002
8/14/2002
8/8/2002
OREQ DUE
7/31/2002
8/8/2002
OREQ DUE
Disapproved-
22050855 420 PLUMBING ROUGH 2 7/26/2002 82 Reinspect Fee Billy Hatcher
7/262002
Required
PLUMBING: WASHING MACHINE NOT VENTED OR OTRAPPED ONEED: 2"
VENT AND TRAP
FOR WASHING MACHINE OAUTOMATED RESULT 10:38:34 26 JUL 2002 (LEGACY INSPECTION)
'
22050855 420 PLUMBING ROUGH 2 7/312002 81 Disapproved
7/312002
1. IMPROPER TERMITE STICKER FORM NOT FILLED GOUT 2. STEEL TOO CLOSE TO DIRT 3. MISSING
ODOWELS INTO EXISTING SLABS DRILLED 8 EPOSIED 048" O.C. 4. WASH MACHINE WASTE ARM HAS BACK
OPITCH 5. USED A SANITARY TEE ON ITS BACK MUST OBE COMBINATION 6. SIDING CANNOT BE INTO
' OCONCRETE OAUTOMATED RESULT 08:22:63 31 JUL 2002 (LEGACY INSPECTION)
22050855 420 PLUMBING ROUGH 2 8/8/2002 90 Approved
8/8/2002
REQ DUE TO FAILED INSP 08:22:53 31 JUL 2002 (LEGACY INSPECTION)
22050865 118 COLUMN 3 8/28/2002 93 Not Required
8/282002
LEITHA461-3928 (LEGACY INSPECTION)
22050855 128 BOND BEAM 3 9/6/2002 90 Approved
9/6/2002
LEITHA 461-3928 OREQ ADDED DUE TO FAILED INSP 09:45:52 28 AUG 2002 (LEGACY INSPECTION)
22050855 900 PLAN REVISION 3 12/512002 90 Approved
12/52002
(LEGACY INSPECTION)
22050855 134 ROOF SHEATHING 4 9/18/2002 81 Disapproved Scott Alley
9/182002
AUTOMATED RESULT 08:07:30 18 SEP 2002 (LEGACY INSPECTION)
22050855 134 ROOF SHEATHING 4 9/19/2002 90 Approved Scott Attey
9/192002
REQ DUE TO FAILED INSP 08:07:30 18 SEP 2002 (LEGACY INSPECTION)
22050855 135 WALLSHEATHING 4
REQ DUE TO FAILED INSP 08:07:54 18 SEP 2002 (LEGACY INSPECTION)
22050855 135 WALL SHEATHING 4 9/18/2002 81 Disapproved Scott Attey
9/18/2002
AUTOMATED RESULT 08:07:54 18 SEP 2002 (LEGACY INSPECTION)
22050855 136 ROOF DRY-IN/TIN TAB 4 9/18/2002 81 Disapproved Scott Attey
9/182002
AUTOMATED RESULT 08:08:14 18 SEP 2002 (LEGACY INSPECTION)
22050855 136 ROOF DRY-INfTIN TAB 4 10/8/2002 90 Approved Scott Attey
10/82002
AUTOMATED RESULT 12:39:12 08 OCT 2002 (LEGACY INSPECTION)
22050855 137 STRAPPING 4
REQ ADDED DUE TO A CANCEL,ROLLOVER,OR PARTIAL 14:15:43 19 SEP 2002 (LEGACY INSPECTION)
Report prepared on 4/11/2019 12:03:22 PM
Inspection Card SCANNED
Permit # : 22050855 �Y
Online address:
http:/lvnvvv.stiucieco.org/planning/permitting.htm St. Lucie County
Quick Links:
Permit Status Lookup
Online Building Inspection System
Page 3 of 3
22050855. 137 STRAPPING 4 9/19/2002
91
Partial Approval
Scott Alley 9/19/2002
FRONT PORCH ONLY. OREQ DUE TO FAILED INSP 08:08:33 18 SEP 2002
(LEGACY INSPECTION)
22050855 137---ZTRA P-NG 4 9/18/2002
81
Disapproved
Scott Alley 9/182002
AUTOMATED ESULS 08:08:33 18-SEP 2002 (LEGACY INSPECTION)
22050855 148 WINDOW/DOOR 4
ATTAGVHj NT
t
Q DfJE70 FAILED INSP 08 0856 8 SEP 20l)2 `(LEGACY INSPECTION)
22050855 148 WINDOW/DOOR 4 9/18/2002
ATTACHMENT
81
Disapproved
Scott Alley 9/182002
AUTOMATED RESULT 08:08:56 18 SEP 2002 (LEGACY INSPECTION)
22050855 167 ROOF FINAL 4 12/6/2002
90
Approved
12/62002
AUTOMATED.RESU6T-ID:W-:37 06 DEC 2002 (LEGACY INSPECTION)
22050855 V 238 ELECTRIC ROUGH 4 _
REQ DUE TO FAILED INSP 08:09,14 18 SEP 2002 (LEGACY INSPECTION)
22050855 238 ELECTRIC ROUGH 4 9/18/2002
81
Disapproved
Scott Attey 9/182002
AUTOMATED RESULT 08:09:14 18 SEP 2002 (LEGACY INSPECTION)
22050855 4 Utv1BING TQW OUT 4 -
o
REQ DUE TO FAILED INSP 08:09:34 18 SEP 2002 (LEGACY INSPECTION)
22050855 423 PLUMBING TOP OUT 4 9/18/2002
81
Disapproved
Scott Alley 9/182002
AUTOMATED RESULT 08:09:34 18 SEP 2002 (LEGACY INSPECTION)
22050855 806 STATUS 4 322/2004
90
Approved
Scott Alley 3/222004
100%COMPLETED NEED BILLY TO LOOK OVER 0LETHA 461-3928
(LEGACY INSPECTION)
22050855 810 HEALTH DEPT- SEPTIC 4
12/3/2002 90 Approved 12/32002
R.CVVDD L`E'TTE_R,EROMj0DI/jUEAL F�DEPT STATING oEXISTING SEPTIC SYSTEM OKAY (LEGACY INSPECTION)
22050855 147 ttWSUV-P , -NAY
�111EGACY INSPECTION)
2F205085 999 � FINAL INSPECTION
-�LEGACYINSPEOTION)
Total Inspections: 33
Report prepared on 4/11/2019 12:03:22 PM