NOTICE OF ACCEPTANCE (NC)A) T(786)315-2590F(786)315-2599
Southeastern Metals Manufacturing Company, Inc. SCHRIN�D
11801 Industry Drive g�
Jacksonville, FL 32218 St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.'The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHI (in areas other than Miami Dade :County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control: Section that this product or material fails to meet the
requirements.of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Weather Vent
LABELING: Each unit shall bear a permanent.label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County.Pmduct Control Approved", unless otherwise noted herein.
-RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or. if there has been a revision or change in the
materials; use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The. NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 13-0,814.08 consists of pages 1 through 3.
The submitted documentation was reviewed by Freddy Semino a
MaftWADECOLW" NOA No.: 18-1212.10
Expiration Date: 4/15/24
Approval Date: - 01/31/19
Page I of
ROOFING ASSEMLYAPPRODAL
Category: Rig.
Sub.Cik ft y: Ventilation
Material:_ Steel
Miolmnm Slope: 2:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:.
ManaPactpred by Test Product
e _ o SoeciHattonu Description
Weather Vent Vent:4-3rx 19" x.46" TAS 106 Galvanized metal roof vent
DeckFlange.24" X 52".
Tbick ness: 0.0217 inch.
MANUFACTURING LOCATION
L Jacksonville; FL'
EVD)ENCE SUBM[TTEb
TestAgencv 'TedIclentlfler TestNtme/Renort Daft
PRI Aspbalt Tecbnologkes, Inc. TAS 100 SEM-002.02-01 08/14/03
ICC-ES AC132 SEM-023-02-01 01/07/14
APPROVED APPLICATIONS -
Deck Type: Wood.
Deck Description: U/32" or Wester plywood or wood plank
System Type A: Mechanical attachment of vent
Cutout: Mark a 31r X460 opening centered between layout lines and aligned minimum 6 inches from
the ridge. Set blade to thickness of sheathing and out opening Brush away sawdust and debris.
Iuehllatlon: Vents should be evenly spaced on the rear slope of the rocit •.
Center vent In opening and set it in a 1/8"thick ofan approved ASTM D 4586 asphalt roofing
cement. Seem vck ent to the roof dewith l-'/a" galvanized ring abank roofing nails spaced
apprax. 8"o.c. and 1" from the oxide edge ofthe flange. Use a minimum of 18 nails per vent.
Seal all nails and vent flange with an approved ASTM D 4586rooflng cement. (See drawings
barei4
Net Pone Ara: 99 squem inches:
NOANo.:1B W210
. Esphudon Date: 04I1=4
Approval Date: 01/31/19
Page 2 of 3
IMMAITONS:
1. Refer to applicable building code for required ventilation
2. Weather Vern shall comply with the mamlfacturds cnnant published.application instructions and the
requirements set forth in the applicable building code.
3. This acceptance is for installations -
4. Weather Vent shall not be installed on roof mean heights greater than 33 feet.
S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code,
6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of
the manufaet:urer's name or logo, city, state, and following statement: 'Maori -Dade County Product.
Control Approved" or the Miami Dade County Product Control Seal as shown below:
DRAWINGS
ROOF FLANGE NAILPLACEMENr
• •
END OF TMS ACCEPTANCE
NOA Nos 1&121210
Espiradon Date: 04/15a4
Approval Date: OW1/19
Page 3 or 3