Loading...
HomeMy WebLinkAboutNOAF1D O PY REVIEW OR CODE p pCOR PLOANCE MIIAAM�t� S p , LUCIE COU.�Ty MIAMI DADS COUNTY .�-.•,....®C� PRODUCTCONTROLSECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 1.1805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE (NC)A) T(786)315-2590F(786)315-2599 Southeastern Metals Manufacturing Company, Inc. SCHRIN�D 11801 Industry Drive g� Jacksonville, FL 32218 St. Lucie County SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.'The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHI (in areas other than Miami Dade :County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control: Section that this product or material fails to meet the requirements.of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Weather Vent LABELING: Each unit shall bear a permanent.label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County.Pmduct Control Approved", unless otherwise noted herein. -RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or. if there has been a revision or change in the materials; use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The. NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 13-0,814.08 consists of pages 1 through 3. The submitted documentation was reviewed by Freddy Semino a MaftWADECOLW" NOA No.: 18-1212.10 Expiration Date: 4/15/24 Approval Date: - 01/31/19 Page I of ROOFING ASSEMLYAPPRODAL Category: Rig. Sub.Cik ft y: Ventilation Material:_ Steel Miolmnm Slope: 2:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:. ManaPactpred by Test Product e _ o SoeciHattonu Description Weather Vent Vent:4-3rx 19" x.46" TAS 106 Galvanized metal roof vent DeckFlange.24" X 52". Tbick ness: 0.0217 inch. MANUFACTURING LOCATION L Jacksonville; FL' EVD)ENCE SUBM[TTEb TestAgencv 'TedIclentlfler TestNtme/Renort Daft PRI Aspbalt Tecbnologkes, Inc. TAS 100 SEM-002.02-01 08/14/03 ICC-ES AC132 SEM-023-02-01 01/07/14 APPROVED APPLICATIONS - Deck Type: Wood. Deck Description: U/32" or Wester plywood or wood plank System Type A: Mechanical attachment of vent Cutout: Mark a 31r X460 opening centered between layout lines and aligned minimum 6 inches from the ridge. Set blade to thickness of sheathing and out opening Brush away sawdust and debris. Iuehllatlon: Vents should be evenly spaced on the rear slope of the rocit •. Center vent In opening and set it in a 1/8"thick ofan approved ASTM D 4586 asphalt roofing cement. Seem vck ent to the roof dewith l-'/a" galvanized ring abank roofing nails spaced apprax. 8"o.c. and 1" from the oxide edge ofthe flange. Use a minimum of 18 nails per vent. Seal all nails and vent flange with an approved ASTM D 4586rooflng cement. (See drawings barei4 Net Pone Ara: 99 squem inches: NOANo.:1B W210 . Esphudon Date: 04I1=4 Approval Date: 01/31/19 Page 2 of 3 IMMAITONS: 1. Refer to applicable building code for required ventilation 2. Weather Vern shall comply with the mamlfacturds cnnant published.application instructions and the requirements set forth in the applicable building code. 3. This acceptance is for installations - 4. Weather Vent shall not be installed on roof mean heights greater than 33 feet. S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code, 6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufaet:urer's name or logo, city, state, and following statement: 'Maori -Dade County Product. Control Approved" or the Miami Dade County Product Control Seal as shown below: DRAWINGS ROOF FLANGE NAILPLACEMENr • • END OF TMS ACCEPTANCE NOA Nos 1&121210 Espiradon Date: 04/15a4 Approval Date: OW1/19 Page 3 or 3