Loading...
HomeMy WebLinkAboutENGINEERING LETTER - GODWIN ENGINEERINGTo: Re: GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 chad(&godwineng.com May 16, 2019 SCANNED St. Lucie County Building Division BY 2300 Virginia Avenue St. Lucie County Ft. Pierce, FL 34982 Bond - Residential PV Roof Mount Installation 3408 Avenue South FILE CU Fort Pierce, FL 34947 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. 1 have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2017 Florida Building Code 6th Edition, FBC ASCE 7 Min. Design Loads for Buildings & Other Structures Per 2017 FBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V"it) - 160mph 3sec gust, Exposure Category - C The PV System consist of the modules, railing, and connection hardware. The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. %" plywood decking and 2" x 4" roof trusses 24" O.C. The roofing, decking, and roof trusses are in good condition. The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the Ironridge railing and flashings/attachments. The attachments can be attached up to 48" apart. The mounts should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The mounts shall be installed with a min. 5/16" lag screw with minimum 2-5/16" thread length. Please see attached documents and contact me should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp.02/28/2021 IC * ; 0 1360 ; =_ l 4 OR �0illAi E\\\\\ SIl6��� BUILDING DESIGN PROPERTIES SYMBOL VALUE UNIT BASICWINDSPEED V 16D I'� mph Figure 26S.1C, page 249a ROOF PITCH B a) to 27 degrees MEAN ROOF MIGHT h 15 F k ROOF SETBACK a 3 k ADJUSTMENT FACTOR FOR BUILDING HEIGHTAND EXPOSURE A 1.21 Figure 30.5-1, pg 347 TOPIGRAPHICALFACTOR K 1 Figure 26.8-1pg252 EXPOSURE C EFFECTIVE WIND AREA 10,:_ of ZONES ZONE2 ZONE3 VARIABLE DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT REFERENCE:ASCE 7.10 NET DESIGN WIND PRESSURE( UPLIFT( P_. 42.1 -73.4 -108.5 psf Figure 30.5-1, pg 346 NET DESIGN WIND PRESSURE (DOWN) P„,p 20.3 20.3 20.3 psf Figure 30.5-1, pe 346 NET DESIGN WIND PRESSURE (UP) P,..o -50.94 88.81 -131.29 psf Calculation: P,.,,p A K.x P..y NET DESIGN WIND PRESSURE (DOWN) P.. m.. 7A.56 24.56 24.56 psf Calculation: P..m.,,=Ax K.x P,.uo DESORPTION DEAD LOAD SNOW LOAD DESIGN WIND LOAD ASO DESIGN LOAD (UPLIFT) DOWNFORCE CASE I DOWNFORCE ME DOWNFORCECASE3 SYMBOL VALUE VALUE VALUE D 5 W Pe.b, Pa.b, P" Penh, m30131.29-9937327.5621.42 DESIGN FACTORS & CALCULATIONS FOR THE USE OF L-FOOT TO ROOFTRU55 DESCRIPTION SYMBOL VALUE VALUE VALUE MODULEWIDTH B TOTAL DESIGN LOAD (UPLIFT) P TOTAL DESIGN LOAD (DOWNFORCE) P DISTRIBUTED LOAD (UPLIFT) w DISTRIBUTED LOAD (DOWNFORCE) RAIL SPAN BETWEEN ANCHORS POINTS L POINT LOAD (UPLIFT) R POINT LOAD (DOWNFORCE) R L-FOOT CONNECTED BY LAG SCREW TO ROOF TRUSS/ RAFTER 5peci0c Gravity, Rafter G Min. Dia. of lag Screw, 5/16 D Pullout Value of W R of lag screws Thread Length T4 Design Pullout Value per Mount W, SAFTEY FACTOR SF 3.28 3.28 3.28 -37.13 -66A7 -99.37 27.56 27.56 27.56 -60.90 -109.01 -162.97 45.20 45.20 45.20 4 . 4 2 -243.61 -436.05 -325.93 190.81 180.81 90.41 0.55 0.55 0.55 0.3125 0.3225 0.3125 306.87 306.97 306.87 1 I 1 23125 2.3125 2.3125 709.64 709.636 709.636 2.91 2.63 2.18 3u.LOenwlaa3m73sIr..N.i1 119 ar/l�imnl YGa�44e�r4.nYdr pMmWN.ak\b a..PymnaYrvrAb� L 3.rl..dJgOalam3 a.3 eel ea.W .n FYa Ilmr Cabre Ree,(4a r)elle {EI UNIT PSI Psf Psf Pat Pat Pat Pat UNIT It psf psf pit pU k Ibs Its Calculation: Pa = D.SORT(0.6)W(asd) Calculation: Pay SDD.1.05 Calculation: Pm=1.DD.1.OW Calmlatlon: Pea m 1.0D.0.755.0.75W Calculation: w= Pa/2.__I.,- Cal.L.Uon:w=PB/2.L _u ae.- Calculation: R=PLB/2'"SY""•".me.�. Calculation: R = PLB/2 •"n"'"""'"`P"°" Table 11.2A, NDS 2005, page 6B (Southern Pine) In Ibs/in W=1800 GM DW4 In Table 12, ND52005 W,= W • R of Lags •Te Calculation: SF=WyR(Uplift) ❑ br�vim. � .a �' • �■ Carr+. lw..