HomeMy WebLinkAboutPLANSGround Access Point
i
-COGEN Disconnect
-- ----- - —
Located near
r1S
Utility meter
T g COPY
R-1
_
REVIEWED FOR
CODE COMPLIANCE
Utility Meter
o
ST. LUCIE COU! TY
O
BOCC O t
Inverter Type: Enphase
PV Panel: (6) Mission 305W
3' Access Pathway
Racking: Iron Ridge
Total Wattage: 1,830W
Roof Type: Composition Shingles
Wind Load: 7 to 27 Deg
Fastener Type: Use 5/16" Dia 4" Lags
R-1
# Modules (4)
Sheet Index
S-1 Cover Sheet / Site Plan
Pitch: 18°
S-2 Detail
E-1 One - Line
Azimuth: 180°
S-IA Mounting Plan
-
General Notes:
-Enphase IQ7 Micro Inverter
are located on roof behind each module.
-First responder access maintained and
from adjacent roof.
-Wire run from array to connection is 40 feet.
Godwin Engineering and
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad@godwineng.com
At least 2' from all gutter
R-2 R-3
# Modules (1) # Modules (1) 51_611
Ground Access Point
PA
Pitch: Pitch: 18°(� L_U
Azimuth: 270° Azimuth: 90° Layout Subject to Change Based on Site Conditions
FRONT OF HOUSE Sc"By �®
St. Lucie County
Legend ® Chimney Meets Florida Fire Prevention Code
® First responder access ;k Satellite
Utility Meter 0 Vent Pipe Represents all Fire Clearance 1 st Responder Access
PV Disconnect including Alternative methods minimum of 36" unobstructed as per
Section R324 of the 2015 IRC
2017 FL Residential Code,6th Edition (2015 International Residential Code - 2nd Printing
modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015
International Energy Conservation Code, County of St. Lucie Code, 2014 National Electric Code.
Customer Info:
Mark Douglas Bond
3408 Ave S,
Fort Pierce, FL
34947
561-685-5880
!&I EH S
�M Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
Date: 5.16.19
Drawn bv: TP
Rev Date: 6.13.19
Page: S-1
IemRld e-XR 100 Rill
General Notes:
GO,5-11
Mid QbMt3�-
9
_ !Yeemdo SCR 100 R211
- L Feet are secured to roof rafters.
@ 48" O.C. using 5/16" x 4" stainless
steel Lag bolts.
- Subject roof has One layer.
- All penetrations are sealed and flashed.
Roof Section I Pitch
R1-R3 1 4/12
Roof Rafter and Spacing Overhang Notes:
211x4" @ 24 O.C.
Designed as per ASCE7-10
Modules mounted flush to roof
no higher than 6" above surface.
1211 1 Generic Truss
Inverter Type: Enphase
PV Panel:
(6) Mission 305W
Racking:
Iron Ridge
Total Wattage:
1,830W
Roof Type:
Composition Shingles
Wind Load:
7 to 27 Deg
Fastener Type:
Use 5/16" Dia 4" Lags
Solar Module
3/8-10 X 3/4
HEX HEAD DOLT\
3/B-7B \
FLANCE NUT
Customer Info:
Mark Douglas Bond
3408 Ave S,
Fort Pierce, FL
34947
561-685-5880
3-5/811
REVIEWED FOR
CODE COMPLMNCE
ST. LUCIE COUNTY
BOCC
lC
``,�' ���.........
Godwin En
i�eerie and g �
Design, LLC * Z860
8378 Foxtail Loop
Pensacola, FL 32526 : 01 4r
D. Chad Godwin, PE®4ORIDP. '��
Chad@godwineng.com ////') ONAL E1�`
Date:
Rev Date:
EH S
MILM Efficient Home Services
9416 Intemational Ct,
St. Petersburg, FL 33716
844-778-8810
5.16.19
TP
6.13.19
S-2
RATEDAC OUTPUT CURRW A
NOMINAL OPERATINGAC VOLTAGE V
In Case of Emergency Call
Efficient Home Services
at 844-778-8810
Note:
-All wiring to meet the 2014 NEC and
Florida electric codes.
-Type of conduit to be determined
on site by contractor.
Inverter Type:
Enphase
PV Panel:
(6) Mission 305W
Racking:
Iron Ridge
Total Wattage:
1,830W
Roof Type:
Composition Shingles
Wind Load:
7 to 27 Deg
Fastener Type:
Use 5/16" Dia 4" Lags
m,lfrN1,011Zi
ram.Fri. �.i tz,t-
1 i ' (01
— Line Side Tap
Customer Info:
Mark Douglas Bond
3408 Ave S,
Fort Pierce, FL
34947
561-685-5880
Enphase Total Output Ckt
C Max Output Current
6
AC Max Output Current * 1.25%
7.5
Overcurrent Protection (A)
10
No. of Current Carrying Cond
<4
Conductor Gauge (AWG)
12
i/
Godwin Engineering and .N� 0 ., c E bs �,/,�%
Design, LLC
8378 Foxtail Loop3so t
Pensacola, FL 32526 0
{fir
D. Chad Godwin PE
Chad@godwineng.com �dNAL
�/lllnlu�����l►3�k
EH S
NOW Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
Date:
Rev Date:
Page:
5.16.19
TP
E-1
14'-
11
R-1
# Modules (4)
Pitch: 18'
Azimuth: 180'
R-3
# Modules (1)
Pitch: 18'
Azimuth: 90'
Max cantilever is 16" as per manufacturer spec.
Max Cantilever = Max Span * (�)=48*(1)=16"
Inverter Type:
PV Panel:
Racking:
Total Wattage:
Roof Type:
Wind Load:
Fastener Type:
R-2.
# Modules (1)
Pitch: 18'
Azimuth: 270'
17' 1
14'
7' �
4'
Flashings 22
UFO's 20
Sleeves/End Caps 16
Solardecks 1
Ground Lugs 4
Enphase
(6) Mission 305W
Iron Ridge
1,830W
Composition Shingles
7 to 27 Deg
Use 5/16" Dia 4" Lags
3
Customer Info:
Mark Douglas Bond
3408 Ave S,
Fort Pierce, FL
34947
561-685-5880
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Godwin Engineering and
Design, LLC
8378 Foxtail Loop =
Pensacola, FL 32526 =
D. Chad Godwin, PE
Chad@godwineng.com
5'-6tt
40 SF Z
T} /ATE
so
F Uia
u
EH S
LIM Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
5.16.19
TP
Rev #: 01
Rev Date: 6.13.19
Page: S-lA
PIERC 60
3OpSIT
I 40W
iCLASS'L'EADING POWER;OUTPUT-
18._ 6►•
;MIM AXUM EFFICIENCY
'POSITIVE P.QW..ER TQLERANGEt
iwwiv,missions'alaccom ;(i(nfo@mis'slorie;dlar:eom'
G1N1�IrE11r= C rWwwa. tali g..,b�4NP{1r - •r:Evls'r•:M e
1
CERTIFIED RELIABILITY
I Tested to UL1703 & IEC standards
1 PID Resistant
SUPERIOR AESTHETICS
I All -black design coupled with outstanding power output
I Ideal for residential & commercial applications
EXTREME WEATHER RESILIENCE
15631 Pa snow load (117 psf) tested load to UL1703
1 185 mph wind rating`
BAA COMPLIANT FOR GOVERNMENT PROJECTS
I Buy American Act
I American Recovery & Reinvestment Act
25=YEAR
LINEAR WARRANTY
12-`YEAR
PRODUCT WARRANTY
1 5 30 15 20 25
YEARS
CERTIFICATIONS
IEC61215/IEC61730/IEC61701 UL1703
L c �L us V6
Power lbard CEC
USUD
-As there are diffemntcertification requirements In different markets, please contact your bpi
Mission Sohr Energy salesrepresentative furtive specificcenifiates applicable to the products In
the region In which the products are to be used.
•135 mph wind radng based upon instzlladgn at 30Por less fixed nit mount
O® re
MISSION SOLAR s
ENERGY of
Electrlal Parameters at Standard Test Conditions (SfC)
Module Type
MSE300SPBT
MSE305SOBT
MSE3105Q8T -
PowerOutput
Pmax
Wp
300
305
310
Module EffidenW_
%
_ 18.05
-18.3_5 _
_.18.65
Tolerance
0'+3%
0-+3%
0'+3%
Short-Circuit.Gurria
lec
A
9.571
9;664-
9.760.
Open Circuit Voltage
Voc
V
40.08
40.10
40.12
RatedCurrent
-Imp-
A...
9.058
9202
'9.345
Rated Voltage
Vmp
V
33.12
33.14
33.17
15
o�
Normal Operating Cell Tempeia N7 (NOCn`
Temperature Coefficient of Pmax
-0.377%/=C
,TemperatureCoefficient'dfilfc
280%7"CT__
_
-
TemperatureCoeffictentofisc
0.039%/=C
Maximum System Voltage
I000VDC'
Operating Temperature Range
-40-C(-40'F) to+85°C(185-F)
Maxbnum Sedes Fuse Rating
20A
Fire Safety Classfication
Class
IFront:&Back Loid(UL standard);
'S63&Pa;(ilZ psf)-_
_
Idad t; uil_vR3 standard''.,�;1
Hail Safety lmpac'tVelocity
25mm at 23 m/s
Solar Cells
Ptype;Mono crystalkne Slicon•.(15675mm)'•
Cell orientation
60 cells (6x10), 5 busbar
16oinm x 999mm x 40mm -
Module drmeosion,
(65511n:x3933Iri:x157 in;).
Weight
18.2 kg (40.1 lb)
Frame
3 2mm{OA26 rat )tempered;
Low don:Anh eflectiyecoating ,
Anodized aluminum alloy
EnrapstiladG
Ethylene WnA ace6te lE*
1-Box
Protection class IP67 with 3 bypass -diodes
Giles.
J.V wire}' m (39 37)nl) _4mm2J 12 AW.G • -
Connector
MC4
Container.___.!-_
Palleis��Pain ,
`305W'_--.._._.�-_)
53'
Double stack
36 936
285AS kW
Iq0',
�l7oublesfack;
28. _ "728
'222.04 kW
Panels
Weight Height
Width Length
Pallet ___
_26_ _1;1051bs,
_ `45:501'45:50'_
'ri7.00'I
Mission Solar Energy reserves the right to make specification changes without notice
DCMMENT CC-MKTC.U012 REY191011 DATE 4-REVISICN Y.0
CLASS LEADING 300-31OW
IEC
61215/ 61730/ 61701
UL 1703 listed
r
uL IS PowerGuard CEC
ti USED
MSE305SQBT:305WP, 60CELLSOLAR MODULE
Cells Temp.=25'C
to -----—Indduntlrrd•=.1,0e0—.dW/m
.305.1 W
B ( Incident. Irrd: 800 'Wlfn
a 2 ,1w
s I Incident Irrd.=600 [W(m
1 .'W
tg a I. Incident Ind.=400 1. m 12
= Incident Irrd.-200 aW/m 58
o�
0 M m A 4
Voltage M
Current -voltage characteristic; with dependence on irradiance
and module temperature
BASIC DESIGN (UNITS: mm)
DraN corm
HNe I�r'T
1 III 1�
MOD
Mounting "do J
eaxuu
i
r
16.00
a.oa-
esaro -
Front View Back View
o®
MISSION SOLA
ENERGY ®�
Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235
Info®missionsolar.com I www.misslonsolar.com
Data Sheet
Enphase Microinverters
Region: AMERICAS
Enphase
M7and 9Q7+
Microinverters
�L
To learn more about Enphase offerings, visit enphase.com
The high-powered smart grid -ready
Enphase IQ 7 Micro'" and Enphase IQ 7+ Microw
dramatically simplify the installation process while
achieving the highest system efficiency.
Part of the Enphase IQ System, the IQ 7 and
IQ 7+ Microinverters integrate with the Enphase
IQ Envoy'", Enphase IQ Battery'", and the Enphase
Enlighten'" monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power -on testing,
enabling Enphase to provide an industry -leading
warranty of up to 25 years.
Easy to Install
Lightweight and simple
Faster Installation with improved, lighter two -wire cabling
Built -In rapid shutdown compliant (NEC 2014 & 2017)
Productive and Reliable
Optimized for high powered 60-cell and 72-cell* modules
More than a million hours of testing
Class II double -Insulated enclosure
UL listed
Smart Grid Ready
• Complies with advanced grid support, voltage and
frequency ride -through requirements
• Remotely updates to respond to changing
grid requirements
• Configurable forvarying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
• The IQ 7+ Micro is required to support 72-cell modules.
ENPHASE.
Enphase IQ 7 and IQ 7+ Microinverters
1UDIIT nerA rnr% 1n7_An_9_Irc / 1n7_An_R_IIc In7D1 IIS_79_9_IIS / rn7D111C49_R_IIS
Carrinvonly usedmodulepairingsl' -
-235W=350W+ -
_ 35�W:. 44U W+ -
`2
Module compatibility
60-cell PV modules only
60-cell and 72-cell PV modules
+ j- m inp_ _—voltage-'
- 4�V'- -
-60 V
.ti
Peak power tracking voltage
27 V - 37 V
27 V -45 V
Opereti.grange..
Min/Max start voltage.
22 V / 48 V
22 V / 60 V
i M6z,6C'shoit ciicbltcGrfent4nioddle lso).
"15A, -
.- :15A, -
OvervoltageclassDCport
II
II
DCport backfeedcurrenC
1 PV array configuration
1x 1 ungmupded array; No additional
OC side protection required,
-AC side woutc6on requites max 20A.6erbranch circuit
VeaK OUIPUI power
az>o:vsr
Maximum continuous output power
240 VA
290 VA
Nominal (L"L) Soltagelrarig'e? _
240 V I
208V h
`240 V /
308 V/ _
211 264 V+
183229 V
21,11264 V
183 229 V_-
Maxlmum continuous output current
1.0 &(240 V)`
1.15 A.(203 V)
1.21 A (240 V)
1 39 AA (208 V)
Nominal ttequeney,� ��_
60�Hz
_
6D
Extended frequency range
_
47 68 Hz
_
47 68 Hz
AC�hort:clicunffault�curFent over3-.cycles
�5 8'Arms
'
Maximum units per 20 A (UL) branch eircuiN 16 (240 VAC)
13 (208 VAC)
73 (MO VAC)
_
11 (<OB VAC)
AC port backfeed current
0 A
0 A
EFFICIENCY
@240 V @209 V @240 V @208 V
Pea�kCEC'efhciehcyy _ 9Li 97.6,•m._ ,97_Lyl4_ 7913,% ' _
♦..- _ ._
�97.096 � �97.0% �
CECwelghted effic'ienoy
97,0`•W 97�0%
MECHANICAL DATA
b y�A�mlent lerjlperatufe.fan+3a - -40°G to+65tiC_ - _ - _ _
Relative humidity range
_
4%to 100%(condensing) -
,Conrtectdrty`pe (fQ760,�2-U5&iQ7pCUS'.j22.Us)
tvtC4r(orAmp(�eeno(N4U1;K.Wpiladdjt(ofjaIQ
Connectoatype (IQ7,-60-B-US 81g7PLUS72-B-US)
Friends PV2 .(MC4 intermateable').
Adaptors for modules with MC4or UTX connectors:
• PV2 to MC4:.order
- PV2 to UTX: order
yet locations yes
ee•--
__,�___� __ -- --- Classy
td, corrosion iesistagtpolymerioenclosure�
+Communlcat�om -
Monitoring
- .-eowenelneepmmumcanontl•. U
Enlighten Manager and MyErtlightert monitoring options
Both options require installation of an Enphase IQ Envoy.
Drsconn—eecUng means: — _
T_I
:The AC and DC conneclors'Itave been ev$(vate3 and approved.liy ULidnuse as the toed:b?eak
-Complance
alsconnecttequlredb,pfEG690�
_
__ _ _
CARuie21 (L 1,1741 SA)
UL 62109.1, UL1741lIEEE7547. FCC Part 15 Class B, ICES-0003 Class B.
CAN/CSA-C22.2 NO. 107.1.01
This product Is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC
and DC conductors, when Installed according manufacturer's Instructions.
1. No enforced DC/AC ratio. Seethe compatibility calculator at hltna-//ennhane.com/en-us/stipport/modyle-comnatibil6ly.
2. Nominal voltage range can be extended beyond nominal if required by the utility.
3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings, visit enphase.com v EN PHAS E.
m 2018 Enphase Energy. All rights reserved. Al trademarks or brands used are the property of Enphase Energy, Inc.
2018-05-24
' • ' B M
SWar Os Not Always Sunny
Over their lifetime, solar panels experience countless
extreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing
enough to buckle a panel frame. s'�
XR Rails are the structural backbone preventing
these results. They resist uplift, protect
against buckling and safely and efficiently _
`�
transfer loads into the building structure.,;;¢: -� __�,
Their superior spanning capability
t_ >
requires fewer roof attachments,_.
reducing the number of roof .;:,,
penetrations and the amount�'Y
of installation time.
XR Rail Family
t
�
L.
,
Force -Stabilizing Curve
Sloped roofs generate both vertical and lateral
forces on mounting rails which can cause them
to bend and twist. The curved shape of XR Rails
is specialty designed to increase strength in both
directions while resisting the twisting. This unique
feature ensures greater security during extreme
weather and a longer system lifetime.
Compatible with Flat S Pitched Roofs
XR Rails are IronRidge offers
compatible with e a range of tilt leg ;
FlashFoot anoptions for flat
® other pitched roof Illiol roof mounting
attachments. applications. l
Corrosion -Resistant Materials
All XR Rails are made of 6000-sedes WF'
aluminum alloy, then protected with an
anodized finish. Anodizing prevents surfaceand structural corrosion, while also providing I�aa more attractive appearance. y e
r,
XR�RaifrFamily
The XR Rail_ Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match.
rr
XR10 .
XR10 is a sleek, low -profile mounting
rail, designed for regions with light or
;no snow. It achieves 6 toot spans, while
'fetnaihing light and economical.
•NB'spanning capability
• Moderate load capability
Clear & black anodized finish
• latemal splices available
Rail Selection
XR100
XR100 is the ultimate residential
mounting rail. It supports a range of
wind and snow conditions, while also
maximizing spans up to 8 feet.
• 8'spanningcapability
• Heavy load capability
• Clear & black anodized finish
• Internal splices available
XR1000
XR1000 is a heavyweight among
solar mounting rails. It's built to handle
extreme climates and spans 12 feet or
more for commercial applications.
• 12'spanning capability
• Extreme load capability
• Clear anodized finish
• Internal splices available
The following table was prepared in compliance with applicable engineering codes and standards. Values are
based.on the -following criteria: ASIDE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.
3P# (cos- 05��