Loading...
HomeMy WebLinkAboutPLANSGround Access Point i -COGEN Disconnect -- ----- - — Located near r1S Utility meter T g COPY R-1 _ REVIEWED FOR CODE COMPLIANCE Utility Meter o ST. LUCIE COU! TY O BOCC O t Inverter Type: Enphase PV Panel: (6) Mission 305W 3' Access Pathway Racking: Iron Ridge Total Wattage: 1,830W Roof Type: Composition Shingles Wind Load: 7 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags R-1 # Modules (4) Sheet Index S-1 Cover Sheet / Site Plan Pitch: 18° S-2 Detail E-1 One - Line Azimuth: 180° S-IA Mounting Plan - General Notes: -Enphase IQ7 Micro Inverter are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com At least 2' from all gutter R-2 R-3 # Modules (1) # Modules (1) 51_611 Ground Access Point PA Pitch: Pitch: 18°(� L_U Azimuth: 270° Azimuth: 90° Layout Subject to Change Based on Site Conditions FRONT OF HOUSE Sc"By �® St. Lucie County Legend ® Chimney Meets Florida Fire Prevention Code ® First responder access ;k Satellite Utility Meter 0 Vent Pipe Represents all Fire Clearance 1 st Responder Access PV Disconnect including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 2017 FL Residential Code,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of St. Lucie Code, 2014 National Electric Code. Customer Info: Mark Douglas Bond 3408 Ave S, Fort Pierce, FL 34947 561-685-5880 !&I EH S �M Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Date: 5.16.19 Drawn bv: TP Rev Date: 6.13.19 Page: S-1 IemRld e-XR 100 Rill General Notes: GO,5-11 Mid QbMt3�- 9 _ !Yeemdo SCR 100 R211 - L Feet are secured to roof rafters. @ 48" O.C. using 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed and flashed. Roof Section I Pitch R1-R3 1 4/12 Roof Rafter and Spacing Overhang Notes: 211x4" @ 24 O.C. Designed as per ASCE7-10 Modules mounted flush to roof no higher than 6" above surface. 1211 1 Generic Truss Inverter Type: Enphase PV Panel: (6) Mission 305W Racking: Iron Ridge Total Wattage: 1,830W Roof Type: Composition Shingles Wind Load: 7 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags Solar Module 3/8-10 X 3/4 HEX HEAD DOLT\ 3/B-7B \ FLANCE NUT Customer Info: Mark Douglas Bond 3408 Ave S, Fort Pierce, FL 34947 561-685-5880 3-5/811 REVIEWED FOR CODE COMPLMNCE ST. LUCIE COUNTY BOCC lC ``,�' ���......... Godwin En i�eerie and g � Design, LLC * Z860 8378 Foxtail Loop Pensacola, FL 32526 : 01 4r D. Chad Godwin, PE®4ORIDP. '�� Chad@godwineng.com ////') ONAL E1�` Date: Rev Date: EH S MILM Efficient Home Services 9416 Intemational Ct, St. Petersburg, FL 33716 844-778-8810 5.16.19 TP 6.13.19 S-2 RATEDAC OUTPUT CURRW A NOMINAL OPERATINGAC VOLTAGE V In Case of Emergency Call Efficient Home Services at 844-778-8810 Note: -All wiring to meet the 2014 NEC and Florida electric codes. -Type of conduit to be determined on site by contractor. Inverter Type: Enphase PV Panel: (6) Mission 305W Racking: Iron Ridge Total Wattage: 1,830W Roof Type: Composition Shingles Wind Load: 7 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags m,lfrN1,011Zi ram.Fri. �.i tz,t- 1 i ' (01 — Line Side Tap Customer Info: Mark Douglas Bond 3408 Ave S, Fort Pierce, FL 34947 561-685-5880 Enphase Total Output Ckt C Max Output Current 6 AC Max Output Current * 1.25% 7.5 Overcurrent Protection (A) 10 No. of Current Carrying Cond <4 Conductor Gauge (AWG) 12 i/ Godwin Engineering and .N� 0 ., c E bs �,/,�% Design, LLC 8378 Foxtail Loop3so t Pensacola, FL 32526 0 {fir D. Chad Godwin PE Chad@godwineng.com �dNAL �/lllnlu�����l►3�k EH S NOW Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Date: Rev Date: Page: 5.16.19 TP E-1 14'- 11 R-1 # Modules (4) Pitch: 18' Azimuth: 180' R-3 # Modules (1) Pitch: 18' Azimuth: 90' Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * (�)=48*(1)=16" Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: R-2. # Modules (1) Pitch: 18' Azimuth: 270' 17' 1 14' 7' � 4' Flashings 22 UFO's 20 Sleeves/End Caps 16 Solardecks 1 Ground Lugs 4 Enphase (6) Mission 305W Iron Ridge 1,830W Composition Shingles 7 to 27 Deg Use 5/16" Dia 4" Lags 3 Customer Info: Mark Douglas Bond 3408 Ave S, Fort Pierce, FL 34947 561-685-5880 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC Godwin Engineering and Design, LLC 8378 Foxtail Loop = Pensacola, FL 32526 = D. Chad Godwin, PE Chad@godwineng.com 5'-6tt 40 SF Z T} /ATE so F Uia u EH S LIM Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 5.16.19 TP Rev #: 01 Rev Date: 6.13.19 Page: S-lA PIERC 60 3OpSIT I 40W iCLASS'L'EADING POWER;OUTPUT- 18._ 6►• ;MIM AXUM EFFICIENCY 'POSITIVE P.QW..ER TQLERANGEt iwwiv,missions'alaccom ;(i(nfo@mis'slorie;dlar:eom' G1N1�IrE11r= C rWwwa. tali g..,b�4NP{1r - •r:Evls'r•:M e 1 CERTIFIED RELIABILITY I Tested to UL1703 & IEC standards 1 PID Resistant SUPERIOR AESTHETICS I All -black design coupled with outstanding power output I Ideal for residential & commercial applications EXTREME WEATHER RESILIENCE 15631 Pa snow load (117 psf) tested load to UL1703 1 185 mph wind rating` BAA COMPLIANT FOR GOVERNMENT PROJECTS I Buy American Act I American Recovery & Reinvestment Act 25=YEAR LINEAR WARRANTY 12-`YEAR PRODUCT WARRANTY 1 5 30 15 20 25 YEARS CERTIFICATIONS IEC61215/IEC61730/IEC61701 UL1703 L c �L us V6 Power lbard CEC USUD -As there are diffemntcertification requirements In different markets, please contact your bpi Mission Sohr Energy salesrepresentative furtive specificcenifiates applicable to the products In the region In which the products are to be used. •135 mph wind radng based upon instzlladgn at 30Por less fixed nit mount O® re MISSION SOLAR s ENERGY of Electrlal Parameters at Standard Test Conditions (SfC) Module Type MSE300SPBT MSE305SOBT MSE3105Q8T - PowerOutput Pmax Wp 300 305 310 Module EffidenW_ % _ 18.05 -18.3_5 _ _.18.65 Tolerance 0'+3% 0-+3% 0'+3% Short-Circuit.Gurria lec A 9.571 9;664- 9.760. Open Circuit Voltage Voc V 40.08 40.10 40.12 RatedCurrent -Imp- A... 9.058 9202 '9.345 Rated Voltage Vmp V 33.12 33.14 33.17 15 o� Normal Operating Cell Tempeia N7 (NOCn` Temperature Coefficient of Pmax -0.377%/=C ,TemperatureCoefficient'dfilfc 280%7"CT__ _ - TemperatureCoeffictentofisc 0.039%/=C Maximum System Voltage I000VDC' Operating Temperature Range -40-C(-40'F) to+85°C(185-F) Maxbnum Sedes Fuse Rating 20A Fire Safety Classfication Class IFront:&Back Loid(UL standard); 'S63&Pa;(ilZ psf)-_ _ Idad t; uil_vR3 standard''.,�;1 Hail Safety lmpac'tVelocity 25mm at 23 m/s Solar Cells Ptype;Mono crystalkne Slicon•.(15675mm)'• Cell orientation 60 cells (6x10), 5 busbar 16oinm x 999mm x 40mm - Module drmeosion, (65511n:x3933Iri:x157 in;). Weight 18.2 kg (40.1 lb) Frame 3 2mm{OA26 rat )tempered; Low don:Anh eflectiyecoating , Anodized aluminum alloy EnrapstiladG Ethylene WnA ace6te lE* 1-Box Protection class IP67 with 3 bypass -diodes Giles. J.V wire}' m (39 37)nl) _4mm2J 12 AW.G • - Connector MC4 Container.___.!-_ Palleis��Pain , `305W'_--.._._.�-_) 53' Double stack 36 936 285AS kW Iq0', �l7oublesfack; 28. _ "728 '222.04 kW Panels Weight Height Width Length Pallet ___ _26_ _1;1051bs, _ `45:501'45:50'_ 'ri7.00'I Mission Solar Energy reserves the right to make specification changes without notice DCMMENT CC-MKTC.U012 REY191011 DATE 4-REVISICN Y.0 CLASS LEADING 300-31OW IEC 61215/ 61730/ 61701 UL 1703 listed r uL IS PowerGuard CEC ti USED MSE305SQBT:305WP, 60CELLSOLAR MODULE Cells Temp.=25'C to -----—Indduntlrrd•=.1,0e0—.dW/m .305.1 W B ( Incident. Irrd: 800 'Wlfn a 2 ,1w s I Incident Irrd.=600 [W(m 1 .'W tg a I. Incident Ind.=400 1. m 12 = Incident Irrd.-200 aW/m 58 o� 0 M m A 4 Voltage M Current -voltage characteristic; with dependence on irradiance and module temperature BASIC DESIGN (UNITS: mm) DraN corm HNe I�r'T 1 III 1� MOD Mounting "do J eaxuu i r 16.00 a.oa- esaro - Front View Back View o® MISSION SOLA ENERGY ®� Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235 Info®missionsolar.com I www.misslonsolar.com Data Sheet Enphase Microinverters Region: AMERICAS Enphase M7and 9Q7+ Microinverters �L To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Microw dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster Installation with improved, lighter two -wire cabling Built -In rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -Insulated enclosure UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable forvarying grid profiles • Meets CA Rule 21 (UL 1741-SA) • The IQ 7+ Micro is required to support 72-cell modules. ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters 1UDIIT nerA rnr% 1n7_An_9_Irc / 1n7_An_R_IIc In7D1 IIS_79_9_IIS / rn7D111C49_R_IIS Carrinvonly usedmodulepairingsl' - -235W=350W+ - _ 35�W:. 44U W+ - `2 Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules + j- m inp_ _—voltage-' - 4�V'- - -60 V .ti Peak power tracking voltage 27 V - 37 V 27 V -45 V Opereti.grange.. Min/Max start voltage. 22 V / 48 V 22 V / 60 V i M6z,6C'shoit ciicbltcGrfent4nioddle lso). "15A, - .- :15A, - OvervoltageclassDCport II II DCport backfeedcurrenC 1 PV array configuration 1x 1 ungmupded array; No additional OC side protection required, -AC side woutc6on requites max 20A.6erbranch circuit VeaK OUIPUI power az>o:vsr Maximum continuous output power 240 VA 290 VA Nominal (L"L) Soltagelrarig'e? _ 240 V I 208V h `240 V / 308 V/ _ 211 264 V+ 183229 V 21,11264 V 183 229 V_- Maxlmum continuous output current 1.0 &(240 V)` 1.15 A.(203 V) 1.21 A (240 V) 1 39 AA (208 V) Nominal ttequeney,� ��_ 60�Hz _ 6D Extended frequency range _ 47 68 Hz _ 47 68 Hz AC�hort:clicunffault�curFent over3-.cycles �5 8'Arms ' Maximum units per 20 A (UL) branch eircuiN 16 (240 VAC) 13 (208 VAC) 73 (MO VAC) _ 11 (<OB VAC) AC port backfeed current 0 A 0 A EFFICIENCY @240 V @209 V @240 V @208 V Pea�kCEC'efhciehcyy _ 9Li 97.6,•m._ ,97_Lyl4_ 7913,% ' _ ♦..- _ ._ �97.096 � �97.0% � CECwelghted effic'ienoy 97,0`•W 97�0% MECHANICAL DATA b y�A�mlent lerjlperatufe.fan+3a - -40°G to+65tiC_ - _ - _ _ Relative humidity range _ 4%to 100%(condensing) - ,Conrtectdrty`pe (fQ760,�2-U5&iQ7pCUS'.j22.Us) tvtC4r(orAmp(�eeno(N4U1;K.Wpiladdjt(ofjaIQ Connectoatype (IQ7,-60-B-US 81g7PLUS72-B-US) Friends PV2 .(MC4 intermateable'). Adaptors for modules with MC4or UTX connectors: • PV2 to MC4:.order - PV2 to UTX: order yet locations yes ee•-- __,�___� __ -- --- Classy td, corrosion iesistagtpolymerioenclosure� +Communlcat�om - Monitoring - .-eowenelneepmmumcanontl•. U Enlighten Manager and MyErtlightert monitoring options Both options require installation of an Enphase IQ Envoy. Drsconn—eecUng means: — _ T_I :The AC and DC conneclors'Itave been ev$(vate3 and approved.liy ULidnuse as the toed:b?eak -Complance alsconnecttequlredb,pfEG690� _ __ _ _ CARuie21 (L 1,1741 SA) UL 62109.1, UL1741lIEEE7547. FCC Part 15 Class B, ICES-0003 Class B. CAN/CSA-C22.2 NO. 107.1.01 This product Is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when Installed according manufacturer's Instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at hltna-//ennhane.com/en-us/stipport/modyle-comnatibil6ly. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v EN PHAS E. m 2018 Enphase Energy. All rights reserved. Al trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 ' • ' B M SWar Os Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. s'� XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently _ `� transfer loads into the building structure.,;;¢: -� __�, Their superior spanning capability t_ > requires fewer roof attachments,_. reducing the number of roof .;:,, penetrations and the amount�'Y of installation time. XR Rail Family t � L. , Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specialty designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat S Pitched Roofs XR Rails are IronRidge offers compatible with e a range of tilt leg ; FlashFoot anoptions for flat ® other pitched roof Illiol roof mounting attachments. applications. l Corrosion -Resistant Materials All XR Rails are made of 6000-sedes WF' aluminum alloy, then protected with an anodized finish. Anodizing prevents surfaceand structural corrosion, while also providing I�aa more attractive appearance. y e r, XR�RaifrFamily The XR Rail_ Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. rr XR10 . XR10 is a sleek, low -profile mounting rail, designed for regions with light or ;no snow. It achieves 6 toot spans, while 'fetnaihing light and economical. •NB'spanning capability • Moderate load capability Clear & black anodized finish • latemal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8'spanningcapability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. • 12'spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based.on the -following criteria: ASIDE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. 3P# (cos- 05��