HomeMy WebLinkAboutGENERATOR CHECKLIST�STUART , FL 34994 SCANNED (772) 288-5916 FAX (772) 288-5911 BY St. Lucie County 1 COUNTY GENERATOR CHECKLIST M Residential ❑ Commercial GF,NERATOR SPECS: Manufacturer: GENERAC Model: 22K Maximum Electrical Output: 22,000 KW Proposed Electrical Demand to be served: 79.55 AMPS Fuel Source: ❑ Gasoline ❑ Diesel ❑ Propane M LP ❑ Other Tank Size: 500 Gals Tank Type: M Underground ❑ Above Ground Generator) ONew ❑ Used ❑ Existing Tank Ei Sub -Base Tank (Attached to Maximum Noise Output: (Full Load) 65 Db (Exercising/Test) 59 Db **Max 60db—Martin County Noise Ord. (Ch. 67, Article 10, Sec. 67.301) X] Insulated Housing ❑ Non -Insulated Housing ❑ No Housing Generator Location: ❑ A* ❑ AE* ❑ AH* ❑ V ❑ VE* IN X Other *All generators installed below FEMA base flood elevation must be anchored. If you are in a Flood Zone, all mechanicals MUST be elevated to meet the minimum base flood elevation PLUS ONE FOOT. Proposed Minimum Clearance is: ft. below ft. above 5ft. horizontally from building & ventilation openings. (Minimum 5 feet required from structures and openings in walls — NFPA 37- Section 4.1.4) Proposed Setbacks From Lot Line: Front: ft. Side 1: ft. Side 2: ft. Rear: ft. *Generator must meet minimum County setbacks. Clearances and setbacks must be shown on the Site Plan. Mounted: ❑ Inside Structure N *Outside Structure (Answer the following:) *Mounted On: El Existing Concrete Slab CK New Concrete Slab Other: Slab Size: Length: 4'8" ft. Width: 3' ft. Thickness: 4 Inches *Anchoring Specs (Type, Size & Spacing): 3/8 X 2 "EXPANSION ANCHORS PER MANUFACTURER SPECIFICATIONS ADA Accessibility Disclosure Statement — This document may be reproduced upon request in an alternative format bk contacting the County ADA Coordinator (772) 320-3131, the County Administration Office (772) 288-5400, Florida Relay 711, or by completing our accessibility feedback form at www.martin.fl.us/accessibility-feedback. Rev.01-19 , i T STUART, FL 34994 (772)288-5916 FAX (772) 288-5911 lectrical Load Calculations Electrical Contractor: OWNER BUILDER Phone No.: -772-260-1039 Fax No.: Project: GENERATOR Location: 18705 MACH ONE DR., PORT ST LUCIE, FL., 34987 Existing Service Feeder Size: 210 Existing Panel Size: 200 Main Breaker Size: 200 Number of Breakers: 36 Existine Loads - 2400 Sq. ft. x3 watts per sq. ft. 7200 watts Appliance cir. @ 1500 watts each watts PROPOSEDLOADS TO Laundry cir. @ 1500 watts each watts BE SERVED BY THE Range @ 8 kw watts GENERATOR Dishwasher and disposal @ 1500 watts each watts 1 Microwave @ 2000 watts 2000 watts 1 Water heater @ 4.5 kw 4500 watts Tankless water heater watts Dryer @ 5 kw watts 1 Refrigerator @ 1500 watts 1500 watts 1 Bathroom 1 @ 1500 watts 1500 watts Sprinkler Pump watts 1 Other well pump 5000 watts Other watts Other watts Sub Total 20230 watts New Loads Pool pump watts Pool light watts Heat pump watts Chlorine generator watts Air blower watts Boatlift watts Other watts Other watts Other watts First 10 kw @ 100% Remainder @ 40% A/C heat @ 100% Total watts 19092 Prepared by: Total20230 watts 10000 watts 4092 watts 5000 watts Divided by 240 volts = 79.55 Date: Amps ADA Accessibility Disclosure Statement— This document may be reproduced upon request in an alternative format by contacting the County ADA Coordinator (772) 320-3131, the County Administration Office (772) 288-5400, Florida Relay 711, or by completing our accessibility feedback form at www.martin.fl.us/accessibility-feedback. Rev.02-19 EXISITNG 300 AMP No 300 AMP 100 AMP SUBPANEL EXISTING NOT BEING SERVED 3-2/0 cu 2" SCHEDULE 80 PVC EXISTING 200 AMP PANEL ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: EL ' DATE:S'Zz' /7 PLUMB: DATE. MECH DATE;.- RECEIVED MAY 2 0 2019 ST: huele Gourity, pmm'"IRfIf10 22K GENERATOR