1 COUNTY GENERATOR CHECKLIST
M Residential ❑ Commercial
GF,NERATOR SPECS:
Manufacturer: GENERAC Model: 22K
Maximum Electrical Output: 22,000 KW
Proposed Electrical Demand to be served: 79.55 AMPS
Fuel Source:
❑ Gasoline ❑ Diesel ❑ Propane M LP ❑ Other
Tank Size: 500 Gals
Tank Type: M Underground ❑ Above Ground
Generator)
ONew ❑ Used
❑ Existing Tank Ei Sub -Base Tank (Attached to
Maximum Noise Output: (Full Load) 65 Db (Exercising/Test) 59 Db
**Max 60db—Martin County Noise Ord. (Ch. 67, Article 10, Sec. 67.301)
X] Insulated Housing ❑ Non -Insulated Housing ❑ No Housing
Generator Location:
❑ A* ❑ AE* ❑ AH* ❑ V ❑ VE* IN X Other
*All generators installed below FEMA base flood elevation must be anchored. If you are in a Flood Zone, all
mechanicals MUST be elevated to meet the minimum base flood elevation PLUS ONE FOOT.
Proposed Minimum Clearance is: ft. below ft. above 5ft. horizontally from building &
ventilation openings. (Minimum 5 feet required from structures and openings in walls — NFPA 37-
Section 4.1.4)
Proposed Setbacks From Lot Line:
Front: ft. Side 1: ft. Side 2: ft. Rear: ft.
*Generator must meet minimum County setbacks. Clearances and setbacks must be shown on the
Site Plan.
Mounted: ❑ Inside Structure N *Outside Structure (Answer the following:)
*Mounted On: El Existing Concrete Slab CK New Concrete Slab Other:
Slab Size: Length: 4'8" ft. Width: 3' ft. Thickness: 4 Inches
*Anchoring Specs (Type, Size & Spacing): 3/8 X 2 "EXPANSION ANCHORS PER MANUFACTURER
SPECIFICATIONS
ADA Accessibility Disclosure Statement — This document may be reproduced upon request in an alternative format
bk contacting the County ADA Coordinator (772) 320-3131, the County Administration Office (772) 288-5400, Florida
Relay 711, or by completing our accessibility feedback form at www.martin.fl.us/accessibility-feedback.
Rev.01-19
,
i
T
STUART, FL 34994
(772)288-5916
FAX (772) 288-5911
lectrical Load Calculations
Electrical Contractor: OWNER BUILDER
Phone No.: -772-260-1039 Fax No.:
Project: GENERATOR Location: 18705 MACH ONE DR., PORT ST LUCIE, FL., 34987
Existing Service Feeder Size: 210 Existing Panel Size: 200
Main Breaker Size: 200 Number of Breakers: 36
Existine Loads -
2400 Sq. ft. x3 watts per sq. ft. 7200 watts
Appliance cir. @ 1500 watts each
watts
PROPOSEDLOADS TO
Laundry cir. @ 1500 watts each
watts
BE SERVED BY THE
Range @ 8 kw
watts
GENERATOR
Dishwasher and disposal @ 1500 watts each
watts
1 Microwave @ 2000 watts
2000
watts
1 Water heater @ 4.5 kw
4500
watts
Tankless water heater
watts
Dryer @ 5 kw
watts
1 Refrigerator @ 1500 watts
1500
watts
1 Bathroom 1 @ 1500 watts
1500
watts
Sprinkler Pump
watts
1 Other well pump
5000
watts
Other
watts
Other
watts
Sub Total 20230 watts
New Loads
Pool pump
watts
Pool light
watts
Heat pump
watts
Chlorine generator
watts
Air blower
watts
Boatlift
watts
Other
watts
Other
watts
Other
watts
First 10 kw @ 100%
Remainder @ 40%
A/C heat @ 100%
Total watts 19092
Prepared by:
Total20230 watts
10000 watts
4092 watts
5000 watts
Divided by 240 volts = 79.55
Date:
Amps
ADA Accessibility Disclosure Statement— This document may be reproduced upon request in an alternative format by
contacting the County ADA Coordinator (772) 320-3131, the County Administration Office (772) 288-5400, Florida
Relay 711, or by completing our accessibility feedback form at www.martin.fl.us/accessibility-feedback.
Rev.02-19
EXISITNG 300 AMP
No
300
AMP
100 AMP
SUBPANEL
EXISTING
NOT BEING
SERVED
3-2/0
cu
2" SCHEDULE 80
PVC
EXISTING 200
AMP PANEL
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
DATE:
EL '
DATE:S'Zz' /7
PLUMB:
DATE.
MECH
DATE;.-
RECEIVED
MAY 2 0 2019
ST: huele Gourity, pmm'"IRfIf10
22K GENERATOR