HomeMy WebLinkAboutGENERATOR PAPERWORK - MANUAL11Q� ; My
BY
St. Lucie County
INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'" Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
• System Status & Maintenance Interval LED
Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Capability to be installed within 18" (457 mm)
of a building*
FEATURES
ST.LAN REVIEW
GENERAC
®
PLAN REVIEW g6
BLOG:
°A� GUARDIAN° SERIES
ELE
DATE, - ci Residential Standby Generators
PLUMB: Air -Cooled Gas Engine
DATE:
DATE: FILE C qCa®®��yy
nc3by Power Rating
Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the head of Generates O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5%Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
GENERAL'
US QUIEfTfS-T---
certification only applies to unbundled units and units packaged with
:uil switches. Units oackaned with the Smart Switch are UL certified in
`Only if located away from doors, windows and fresh air intakes,
and unless otherwise directed by local codes.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULA710N:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at �1%.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
J PROTOTYPE TESTED J NEMAMGI.22EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
V SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
w GENERAC ; %I'26s. *'°�° Mole
PROMISE Z�®�° S.. 1
• &urt N M OF uI^O Avw uc oN M' NM Ou 4
GENERAC®
16/20/22 kW
features and benefits
Engine
•
GeneracG-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma molyrings helpsthe engine
run cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok' cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignitiorVspark advance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage to ±1 % prevents damaging voltage spikes.
•
UL 2200 listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers your vital electrical loads to the energized source of power:
•
NEMA 311
Can be installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
Evolution" Controls
•
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, al -a -glance status indication in any condition.
•
Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner. -
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
•
SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
•
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
•
Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 18' away from a building.
Installation System
• 10 (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life
16/20/22 kW
GENERACe
specifications
Generator
Mni1o1 G007035-0, G007036.0, G007038-0, G007039.0 G007042.1, G007043.1
Sated A6 Frequency 60 Hz _ 60 HE 60Hi
Power Factor 1.0 1.0 1.0
Engine
[IAnIOon System Solid -stale w%Magneto Solid-'state'w/Magneto Solid-state w/Ivlagneta
Governor System Electronic Electronic Electronic
Compression 8'atto —T.-5-1-9-5 1975.1—,
Starter 12 Vdc 12Vde 12 Vdc
Natural Gas W/hr (ma/hr)
1/2 Load 218 (6.17), 204 (5,78)
228 (6.46)
Full Load 309 (8.75) 301 (8.52)
327 (9.26).
Liquid Propane ft/hr (gaVhr) [Vhr]
112.Load 91.6 (2.52) 19.531 86 (2.37) 18.991
92 (2.53) [9,571
Full Load 106.8 (2.94) [11.11] 129.6 (3.56)-[13481.
142 (3.90) [14.771
Note: Fuel pipe must be sired for full load. Required fuel pressure to generator fuel inlet at all load ranges- 3.5-7° water column (7-13 mm mercury) for natural gas, 10-121water column (19-22 mm mercury)
for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megaloule content, multiply ma/hr x 93.15 (LP) or ma/hrx 37.26 (NG)
Controls
2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation.
Charger FaulVMissing ACWaRng _ Standard
Low Battery/Battery Problem Protection and Battery Condition Indication Standard `
-Sound levels as taken from he front orthe generator. Sound haelstakenhomother sides oflhegene atormaybe higher depending onhstallaonparameters. RatNgderinitons-Sandby.Applicableforsupplyng emergency lower torthe dua4m
of he ufflypmroutage No overload tapabiglyis available for this allng. (All ratings in accordancewih BS5514, IS03046 and DIN6271). ' Maximum Manuel amps a d current we subject to and limited by such factors as fuel BtLvmeploule
coolant, ambient lempealdre,aultude,engine power and mudguard, e1c. Maximum power demea as about 3.5percentfar each 1.000feet (304.8 meters) above sealml;aMalso Wil decrease about I percent for each 6°C(10°F)above 16°C(60°F)
16/20/22 kW
Limited Circuits Switch Features
• 16 space, 24 circuit, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2-pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA(UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1"standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
Height
Width
H7
H2
W1
W2
Depth
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
110-#14
2/0-#14
210-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to tour air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managedwhen used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, 1e
Open Transition Service Rated
Heigh)
Width
H1
H2
W1
W2
Depth
In
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
GENERAC`
switch options
Model
0007036-0 (ININ)
No. of Pales
2.
Current Rating (Amps)
100
Voltage Rating (VAC)
120/240.10
Utility Voltage Monitor (Feed)'
-Pick-up
-Dropout
60%
65%
Return to Utilily'
- approx. l5 sec
Exercises bi-weekly for 5 minutes'#
Standard
ULlisted
Standard
Total Circuits Available
24
Tandem Breaker Capabilities
8landems
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts
10,000
*Function of Evolution Controller
Exercise can be set to weekly or monthly
Model
G007037.0 (16 kW)/GO07039.0 (20IN)y
G007043-0 (22 kM
No. of Poles
2
Current Rating (Amps)
200
Voltage Rating (VAC) _
_ 120/240.10 _
utility Voltage Monitor (Faed)'
-Pickup
-Dropout
80%
65%
Bella to utility'
_ approx 13 sec
Exercises hi -weekly for 5 minutes'
Standard
UH:Ivted
Standard
Enclosure Type
NEMANL 311
Circuit Breaker Protected
22,000
Lug Range
250 MCM-#6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
1
16/20/22 kW
GENERAC
available accessories
Model # Product Description
The Wi-H enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Men
G007005-0
Wi-F LP Fuel Level Monitor
itorng the LP tank's fuel level is an important step in making sure your generator is ready to me during an
unexpected power failu re. Status alerts are available through a free application to notify when your LP tank
is in need of a refill.
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac-
G006463-4
Mobile Link'"
cess to an Internet connection from a PC orwith any smart device. You will even be notified via e-mail or
text message when a change in the generators status occurs. Available in the U.S. only.
G005819-0
26R Wet Cell Battery
Every standby generator requires a battery to stadthe system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
G907101-0
Battery Pad Warmer
The pad warmerrests underthe battery. Recommended for use if the temperature reguladyfalls below 0°F.
(Not necessary for use with AGM -style batteries).
G007102-0
Oil Warmer
Oil warmer slips directly over the oil fitter. Recommended for use if the temperature regularly falls below
0"F.
G005621-0
Auxiliary Transfer Switch
The auxiliary transfer switch contact lot allows the transfer switch to lock out a single large electrical load
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
Base Wrap Kit
Fascia Ba se
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
G007027-0 -Bisque
(Standard
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from
G005703-0- Bisque
Paint Kh
future corrosion. The paint kit includes the necessary paint to property maintain or touch-up a generator
enclosure.
G006485-0
Scheduled Maintenance Kit
Generates scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
G006873-0
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
(50Amps)
power management capabilities. Itprovides additional power management flexibility notfound in any other
power management system.
dimensions & PCs
Dimensions shown weappmdmate. Refer to installagan manual for met dimenslons. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
IE"SIOENEW
MOW MEW
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007042-0
696471070422
G007043-0
696471070439
GENE RAC® Generac Power Systems, Inc. " S45 W29290 HWY. 59, Waukesha, WI 53189 " generac.com
02017 Gen area Power Systems, Inc. All rights reserved. All specifications are subject to change who out notice. Part No. 10000DO0194-F 5/3/17
RECEIVED
MAY 2 0 201.9
ST. Lucie.county+ rermItting
FILE Copy
:OUNTY
VIEW
DATE:
ELE 1
DATE:���1
PLUMB:
DATE:
MECH:
DATE: