HomeMy WebLinkAboutENGINEERING LETTERPAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com May 10, 2019 SCANNED Re: Fugazzoto Re -Roof BY 10701 S Ocean Dr. #728 St. Lucie County Jensen Beach, FL 34957 RECEIVED MAY 2 0 1019 perMlttln St, Ly9;��PU�tyent SCOPE OF WORK: Install new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp" FL #17022.1) at the above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2017 ASCE7-10 PROJECT DATA: BUILDING HIEGHT = I V-0" A= 3' MEAN ROOF HIEGHT = <15' ROOF ANGLE = 3:12 SHAPE = PITCHED GABLE ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR =1.00 WIND VELOCITY V ult = 165MPH WIND VELOCITY V asd =128 MPH EXPOSURE = D ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF): ZONE 1 (Field) = -40.3 ZONE 2 (Perimeter/ Ridge) = -68.0 ZONE 3 (Comers) = -99.8 Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 May 10, 2019 AAl 10701 S Ocean Dr. #728 Jensen Beach, FL ✓ 1 of 3 Metal roofing to be attached with corrosion resistant Hex -Head wood screws #10 x 1 %z" minimum with weather sealing washers (minimum 3/16" penetration through deck). Fasteners shall be placed through the panel ribs at 12" on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING = 16" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C. ZONE 3 (Comers): FASTENER SPACING= 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-101PSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be 30# Roofing Felt. DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL # 17022.1), manufacturer's specifications, and the Florida Building Code 2017. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 May 10, 2019 10701 S Ocean Dr. #728 Jensen Beach, FL / 2 of 3 Ll ROOF ZONE PLAN A=3 , 1QQ2 , 3Q= ZONE DESIGNA770N (MICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HOR7, Paul Welch Inc. P ul Welch P.E. Reg. No. 29945 May 10, 2019 10701 S Ocean Dr. #728 Jensen Beach, FL 3 of 3