HomeMy WebLinkAboutENERGY EFFICENCY CODEFILE C®PY6r FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Osteen Residence I Milder Name: SCANNED Street: 8505 Immokolee Road JUL 0 2 ��'9 4rmit Office: St. Lucie CountyB� City, State, Zip: Fort Pierce, FL, 34951 P fruit Number: 7 L+4 St. Owner: Osleen Residence Jurisdiction: St. Lucie County Lucie Cou* Design Location: FL, Fort Pierce t C ck County, Permitting ST. Lu__ _. County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (848.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 848.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (602.0 sgft.) Insulation Area a. Under Attic (Vented) R=38.0 602.00 ft2 6. Conditioned floor area above grade (ft2) 602 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(93.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 85 a. U-Factor: Dbl, U=0.65 93.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.8 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.341 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (602.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 602.00 ft b. Conservation features EF: 0.950 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF. Pstat Glass/Floor Area: 0.154 Total Proposed Modified Loads: 25.32 PASS Total Baseline Loads: 26.65 a771t I hereby certify that the plans and specifications covered by Review of the plans and STgl, this calculation are in compliance with the Florida Energy specifications covered by this o'e-VUE �2 = 60 Code. calculation indicates compliance �7/1 = with the Florida Energy Code. y'� h rna,:,. ••. _',.••y�„ r0 PREPARED Before construction is completed r C DATE:M-(AQ� this building will be inspected for compliance with Section 553.908 I hereby certify that this building designe , is mpliance Florida Statutes. _ yt with the Florida Energy Code. G'0 WF. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/17/2019 11:29 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Osteen Residence Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 602 Lot # Owner Name: Osteen Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlalBook: Builder Name: Rotate Angle: 0 Street: 8505 Immokolee Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 602 4816 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Bathroom 54 432 No 0 1 Yes Yes Yes 2 Closet 30 240 No 0 1 Yes Yes Yes 3 Bedroom 154 1232 No 2 1 Yes Yes Yes 4 Great Room 182 1456 No 2 1 Yes Yes Yes 5 Kitchen 144 1152 No 2 1 Yes Yes Yes 6 Laundry 38 304 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Bathroom 15 ft 54 ft2 _ 1 0 0 2 Slab -On -Grade Edge Insulatio Closet lift 30 ft2 _ 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 14 ft 154 ft2 — 1 0 0 4 Slab -On -Grade Edge Insulatio Great Room 27 ft 182 ft2 __ 1 0 0 5 Slab -On -Grade Edge Insulatio Kitchen 25 It 144 ft2 1 0 0 6Slab-On-Grade Edge Insulatio Laundry 14 ft 38 ft2 ____ 1 0 0 6/17/2019 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 673 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 602 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Bathroom 38 Batt 54 ft2 0.1 Wood _ 2 Under Attic (Vented) Closet 38 Batt 30 ft' 0.1 Wood 3 Under Attic (Vented) Bedroom 38 Batt 154 ft2 0.1 Wood _ 4 Under Attic (Vented) Great Room 38 Batt 182 ft2 0.1 Wood _ 5 Under Attic (Vented) Kitchen 38 Batt 144 ft' 0.1 Wood 6 Under Attic (Vented) Laundry 38 Batt 38 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext InsuBathroom 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InsuBathroom 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 3 N Exterior Concrete Block - Ext Insul Closet 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 _ 4 E Exterior Concrete Block - Ext Insul Closet 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 5 E Exterior Concrete Block - Ext Insu®edroom 4.1 3 0 8 0 24.0 ft2 0 0 0.6 0 _ 6 W Exterior Concrete Block - Ext Insu®edroom 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 _ 7 S Exterior Concrete Block - Ext InsGreat Room 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext InsGreat Room 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 9 E Exterior Concrete Block - Ext Insul Kitchen 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block - 6d Insul Kitchen 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 _ 11 N Exterior Concrete Block - Ext Insul Laundry 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 12 E Exterior Concrete Block - Ext Insul Laundry 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 DOORS # Ornl Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 S Wood Great Room None .39 3 6 10 20.5 ft2 2 N Wood Laundry None .39 3 6 10 20.5 ft2 6/17/2019 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered. Proposed orientation. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int.Shade Screening 1 N 1 Metal Low-E Double Yes _ 2 W 6 Metal Low-E Double Yes 3 S 7 Metal Low-E Double Yes 4 W 8 Metal Low-E Double Yes 5 E 9 Metal Low-E Double Yes 6 S 10 Metal Low-E Double Yes 0.65 0.25 N 6.0 ft= 1 ft 5 in 1 ft 4 in 0.65 0.25 N 15.0 ft= 1 ft 5 in 1 ft4 in 0.65 0.25 N 12.0 ft- 5 ft 0 in 1 ft 4 in 0.65 0.25 N 24.0 ft= 1 ft 5 in 1 ft 4 in 0.65 0.25 N 24.0 ft- 1 ft 5 in 1 ft 4 in 0.65 0.25 N 12.0 ft- 5 it 0 in 1 ft 4 in None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 561.9 30.85 58.01 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 18.8 kBlu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM VV # System Type SubTpe Location EF Cap Use SelPnt Conservation 1 Electric None Laundry 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft= DUCTS / —Supply——Return— Air CFM 25 CFM25 V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 85 ft= Attic 15 ft= Default Leakage Attic (Default) (Default) 1 1 6/17/2019 11:29 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programabl[e Ceiling Fans: ]Thermosta[[t:��Y Heating [X] Jan [X] Feb [[ ]] [X] Me Mar Ap Apr May Jun �C] f ]Jul r Aug I [X� Sep Oct Oct ov Nov Dec Venting ll 11 Jan [[ ]] Feb ((fix]] Mar [ lXl Jun [ 1 Jul 111 Aug Ex� [ Sep XH Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 Bathroom Default(8 lbs/sq.ft. ft' ft 0.3 Closet Default(8 lbs/sq.ft. ft' ft 0.3 Bedroom Default(8 Ibs/sq.ft. ft' ft 0.3 Great Room Default(8 lbs/sq.ft. ft' ft 0.3 Kitchen Default 8 Ibs/s .ft. ft' ft 0.3 Laundry 6/17/2019 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Osteen Residence Builder Name: Street: 8505 Immokolee Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34951 Permit Number: V Owner: Osteen Residence Jurisdiction: St. Lucie County = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the lop plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Dining a dwiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler coyer plates and walls or ceilincis d. In auamon, inspection or log wars shall be in accordance with the provisions or ICU-4UU. 6/17/2019 11:29 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 18.8 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 602 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 93.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2, Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 14. Heating system: Capacity 17.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 1062. 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11 a. 38.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied it the Florida Building Code, Energy Conservation, through the above energy saving features which will be in d r exceeded) in this home before final inspection. /tIrwise anew EPL display card will be completed be d n install d cc a compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: Fort Pierce, FL 34951 611712019 11:29:42 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft 317 St. Lude Lane. Fort Project Summary Entire House Quick Calcs, Inc. SCANNED St. Job: Date: By: R,E�.EIVED For: Osteen Residence 8505 Immokolee Road, Fort Pierce, FL 34951 2 ?ONIles: FILE C `� c- ,•^County, Permitting 'Design ormation Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10191 Btuh Structure 11921 Btuh Ducts 1846 Btuh Ducts 2391 Btuh Central vent (0 din) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12036 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 13596 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2473 Btuh Ducts 736 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 602 602 Equipment latent load 3209 Btuh Volume (ft) 4816 4816 Air changes/hour 0.61 0.32 Equipment Total Load (Seri+Lot) 16805 Btuh Equiv. AVF (cfm) 49 26 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40181-1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.6 kW Sensible cooling 13160 Btuh Heating output 12320 Btuh Latent cooling 5640 Btuh Temperature rise 18 OF Total cooling 18800 Btuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +� wrlgFs�oi�t- 2019-Jun-1709:55:19 Right -Suite® Universal 201919.0.01 RSU08101 Pagel ...\Dowments\VJrtghtsoft HVAC\Osteen Residence.rup Cale =MJS Front Door faces: N +# wrightsoft• Right -A) Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772<66-6799 Email: quickcalcs@aol.com 11 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 106.0 ft &0 ft 602.0 ft2 Bathroom 15.0 ft 8.0 If heat/cool 9.0 x 6.0 ft 54.0 ft2 Ty number number I jl�value (Bluhttt'-°F,9I I Or HfM (Btuh/ft2) Area (ete or perimeter t2) (ft) Load Load Area ((te I or perimeter (ft) Load I Load Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool tllll r 6 11 G 13A-40cs 4A5-2om ^^ 1100 13A-4ocs 4A5-20m 0.143 0.770 n n. '= 4400 2156 -�2.19 19.31 30 _ 70,4 2.19 47.10 "— 184 6 ;158 -,. 0 __20'_s223 216 0 631 129 865 517 345 116 _211 473 113C T9— -72 6 _�___,_0 0 0 66 0 A 0 0 ._: 264 129 0 144 ' 116 c " 0 Vj1 L—G ___0.390 0.143 0.770 ,n a a -r10.92. 4.00 21.56 �.2 240 24 0 0 0 0 i—G 13A 4ocs • - 4A5-2om 11D0 0.143 0.77D -,_,-_ 0,39D 0.143 0.770 0.770 a 0.026 - s s _.a w w w 4 00 21.56 __ 0.92 4.00 21.56 21.56 r0.73 —2.19 19.31 70,34 2.19 47.10 47.10 184 24 _20 240 24 15 140 -24 r20 589 . 517 __223 305 463 211 - - 0 0 L_O — 0 . 0 0 0 „S 0 L - p : 00 , ° 0 ,w;_0 II----DD 13A-40cs. 4A5-2om 4A5-2om J6B-38nIE V� 22A-[pl 201 0 0 805 517 323 440 1130 707 = 783 0 48 0 _ 0 '„ '_54 54 48 0 0 192 0 0 =39. 415 105 0 0 =70 0 F ,T fM =.602 �„_602 =438 =54 15 0.989 27.69 0.00 602 106 2— 7�- 61 AED excursion 174 -25 Envelope loss/gain i 8684 6487 1 1 1041 411 12 a) Infiltration b) Room ventilation 1507 0 423 0 213 0 60 0 13 Internal gains: Occupants @ 230 Appliances/other 7 1610 3400 0 0 0 Subtotal (lines 6 to 13) 10191 11927 1254 471 14 15 Less eMemal load Less transfer Redistribution Subtotal Duct loads 18% 20% 0 0 0 10191 1w 0 0 0 11921 2391 18% 20% 0 0 0 1254 227 0 0 0 471 94 Toal mom load65 Air required(cfm) I I I 12662271 74312 627I I I 81 7477I 525I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wNgti!Md2tr 2019Jun-Jun09:55:19 Right-S esidennlvers Cale= 1J8 Fr RSUor faces- Pagel ...\Documen4s\Wrightsoft HVAC\Osteen Residence.nrp CaIc=MJB Front Door faces: N + wrightsoft Right-JO Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fad Pierce, FL 34946 Phone: 772.466-6799 Email: quickcalcs@aol.wm 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Closet 11.0 ft 8.0 ft heat1cool 5.0 x 6.0 ft 30.0 W Bedroom 14.0 R 8.0 ft heat1cool 14.0 x 11.0 It 154.0 fP Ty Construction number U-value (Btuh/fl'-'FJ� or HTM (Btuh/fl� I Area (W) or perimeter (ft) I Load (Btuh) I Area (M or perimeter (0) I Load (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross WP/S Heal Cool 6 11 13A-flocs 4A5-tom 1100 13A-40cs 465.2om 0.143 0.770 0.390 0.143 0.770 n n _n_ a a 4.00 21.56 _10.92 4.00 21.56 2.19 19.31 70.34 2.19 47.10 40 0 -0 48 0_ 40 0 0 160 0 0 88 0 0 0 0. 0 " 0 0 0 0 0 0 0 0 0 _ y/ L-G 48 0_ 192 0 105 0 24 0 24 0 96 0 53 0 13A-0ocs 4A5-20m 11 DO 13A-0aa 4A5-2om .4A5- am 16B-38md 22LM 0.143 0.770 0.390 0.143 0.770 0.770 _0.026 s s _s w w w �_ 4.00 21.56 10._92. 4.00 21.56 21.56 --0-.73 27.69 2.19 19.31 10,34 2.19 47.10 47.10 _130 0.00 U 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 . 0 0 0 0 �' 0 0 _ _ _ q0. •' 0 0 �D - Yy C_ F 0 0 0 --30 30 0 0 0 ,._30 11 0 0 0 ��22-__39 305 0 0 0 0 88 0 15 _154 154 73 0 0 „ 154 14 292 0 323 ,�,-112 388 160 0 707 _200 0 0.989 _ _ 61 c) AED excursion _1q 224 Envelope lossfgain 679 218 1 1 1212 1343 12 a) Infiltration b) Room ventilation 156 0 44 0 58 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 2 E01411 460 0 Subtotal lines 6 to 13) 835 262 1859 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 18% 20% 0 0 0 835 151 0 0 0 262 53 18% 20% 0 0 0 1411 256 0 0 0 1859 373 Alr�equired (efm) I I I 951I 314I I 18g7I �g81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed rr+s- '2" 2019-Jun-1709:55:19 Right-Sulle® Universal 201919.0.01 RSU08101 Page J e 2 ...\Documents\Wrightsoft HVACIOsteen Residence.mp Colic =MJB Front Door faces: N +� wrightsoft' Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quicxcalos@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Great Room 27.0 It 8.0 it heaVcool 14.0 x 13.0 R 182.0 fP Kitchen 25.0 8 8.0 it healfcool 9.0 x 16.0 0 144.0 fP Ty Construction number U-value (Btuh/ftk'F Or I HiM (Btuh/ft' I Area (W) or perimeter (it) I Load (BNh) I Area (fl•) or perimeter (0) I Load (Btuh) Heal Coal Gross WP/S Heal Cool Gross N/P/S Heal Cool r 6 11 Vjr G 13A4ocs 4A5-2om 1100 13A4ocs 4A5.2om 0.10 0.770 0-390 n n n 4.00 21 Elt _10.92 4.00 21.56 2.19 19.31 _10.34 2.190 47.10 0 0 ___0 0 0 0 0 0 0 --_0 0 0 '0 0 0 0 0 0 0 '0 0 "0 0 0 T^� 0 po 0 L-D y/ �G 0.143 0.770 a a 0 0 0 0 128 24 104 0 416 517 228 1130 W I�-DG 13A-0ocs. 4A5.2om 1100 13A-4ocs 4A5.2am 4AS20m _163738mtl 22A-tpl 0.743 0.770 0.390 0.143 0.770 0.770 _0.026 0.969 s s = w w w 4.00 21.56 10.92_70.34 4.00 21.56 21.56- _0.73. 27.69 2.79 19.31 2.19 47.10 4710 _.__,1.30 112 12 20 104 24 0 so 12 i_20 80 0 0 319 259 223 320 517 0 174 232 �211 175 113C 0 72 12 80 12 0 240 259 0 -- 731 2.32 0 _ Vf/ _,0 0 0 0 0 0 0 0 0 0 0 0 0 C_ F ,__182 �182 _„_,._732 -237 -749 144 _744 25 105 692 �187, 0 0.00 182 27 748 0 6 c) AED exalrsion I 272 _222 Envelope loss/gain I 2516 2430 2230 7887 12 a) Infiltration b) Roomventilation 384 0 108 0 355 0 100 0 13 Internal gains: Occupants@; 230 Appliances/other 2 460 gop 2 1 460 2000 Subtotal (lines 6 to 13) 2902 Me 25851 4246 14 15 Less external load Less transfer Redistribution Subtotal Duct leads 18% 20% 0 0 b 2902 526 0 0 0 3898 782 18% 20% 0 0 0 2585 468 0 0 0 4246 852 Ahlrequvetl (cfm) I I 1178I 4205I I I 307554 9I 5223I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -1}.'J- wrlgt=IDs� Te- 2019-Jun-1709:5519 Right-S esid Universal Cale= 1J8 Fr RSUor faces: Page3 ...\DocumentslNkightsoft HVAClOsteen Resitlence.mp CaIc=MJB Front Door faces: N +wrightsoft Right-M Worksheet Job: Enure House Date: eY: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qu1Ucalcs@a0Lc0m 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Laundry 14.0 ft 8.0 ft heattwol 1.0 x 38.0 ft 38.0 ill Ty Construction number U-value (BtuNftz-F Or I HrM (Btuh/ft� I Area (ft-) or perimeter (ft) I Load (Stuh) I Area or perimeter I Load Heal I Cool Gross NIP/S Heat Cool Gross I N/P/S Heat Cool 6 71 W�--G 73A-40cs 4A5-2om 11 D0_ 13A.4ocs 485-20m 0.743 0.770 ri n �4.00 21.56 �10,I 4.00 21.56 2.18 19.31 10.34 2.19 47.10 72 0 20 52 0 20 40 0 207 _ 0 __-223 160 0 773 0 e._211 88 0 _ ! -=^ YpI I---G _0._390 0.143 0,770 _n-, a a 40 0- �-G _ 13A-flocs 4A5-2om 11D0 _ 13A-40cs 4A5-2om 0,5r2om 16B-38md 22A-tpl _ 0.143 0.770 _ 0.390 0.143 0.770 _0.770 . s s __s_ w w w_ = 4.00 21.55 _10.92 4.00 21.56 �21.58 = 0.73. 27.69 2.19 19.31 70.34 2.19 47.10 47.10 �_1.30 0.00 0 0 _ _0 0 0 0 ____38 38 0 0 0 0 0 0 0 0 0 _ _28 388 0 0 , - t�1 �G 0 0 0 _- 38 14 __0 0 0 Lam' C- F _49 0 __0026 0.989 6 c) AED excursion -82 Envelope loss/gain i 1005 399 12 a) Infiltration b) Room ventilation 199 0 56 0 13 Internal gains: Occupants 230 Appliances/other 1 230 5 00 Subtotal (lines 6 to 13) 1 12041 1185 14 15 Less external load Less transfer Redistribution Subtotal Duct leads 18% 20% 0 0 0 1204 218 0 0 0 1185 238 brrequired (cfin) I I ia7gl 1462I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -sw wrigtsiso-T 2019-Jun-1709:55:19 Right -Suite® Universal 201919.0.01 RSU08101 Page ...\DocumentstWrightsoft HVAC\Osteen Residence.mp Cale =MJ8 Front Door faces: N '�- WrightsoftDuct System Summary Entire House Quick Calcs, Inc. 317 St Lucia Lane, Fart Pierce. FL 34946 Phone: 772-466-6799 Email: quickcalcs@aoLcom For: Osteen Residence 8505 Immokolee Road, Fort Pierce, FL 34951 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (fEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.376 in/100ft 627 cfm 133 ft Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.376 in/100ft 627 cfm Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FIR Diam (in) H x W (in) Dud Mad Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bathroom h 1481 77 25 0.393 6.0 Ox 0 VIFX 12.2 115.0 stl Bedroom c 2231 87 98 0.398 7.0 Ox 0 VIFx 10.7 115.0 stl Closet h 986 51 14 0.399 5.0 Ox 0 VIFX 10.4 115.0 stl Great Room c 2340 89 102 0 0 Ox0 VIFX 0 0 Great Room -A c 2340 89 102 0 0 Ox 0 VIFx 0 0 Kitchen c 2549 80 112 0.377 7.0 Ox 0 VIFX 17.7 115.0 st2 Kitchen -A c 2549 79 112 0.376 7.0 Ox 0 VIFx 18.1 115.0 st2 Laundry h 1422 74 62 0.390 6.0 Ox 0 VIFx 13.2 115.0 stl 1 4J= 1 ;,I Supply Trumk.betAil Table Trunk Htg Clg Design Veloc Diam H x W Dud Name Type (Cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 159 223 0.376 505 9.0 0 x 0 VinlFlx st1 Peak AVF 289 199 0.390 530 10.0 0 x 0 VinlFlx Name Grille Size (in) Htg (dm) Clg (Cfm) TEL (ft) Design Veloc FIR (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Mad Trunk rbl Ox0 627 627 0 01 0 0 Ox 0 VIFx Wrightsoft- 2019-Jun-17 09:55.20 Right -Suite® Universal 201919.0.01 RSU08101 Pagel Hwn...0.cumems\Wrightsoft HVAC\Osteen Residence.mp Cale =MJ8 Front Door taws:N