HomeMy WebLinkAboutPRODUCT APPROVAL1
..�-,
:w2
BLTs Home
I� M User Registration NO Topla `. SubMI surdurge Stets a Fats I Nbforio. Contact Us ' MS Site Map Un{ search
SCANNE®
dbpr
d --yA�+^ Product Approval ��
�'17�"IUSER:hiblicUser
ttte"""R��^Anmow.I
gyp. Lucie County
Qro111n
M11env> pm:1u[t or Aaopcahon S=artt > q r L t> ADpnmtion Derail
LLw._.._.�...�
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Emall
Authorized Signature
Technical Representative
Address/Phone/Emall
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida license
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL28059
New
2017
Applied For
MAY 21 2019
S - 60cm Cdunty,
Extreme Metal Fabricators, LLC
2160 SW Potna Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.cem
Richard MCKuhen
flvalidation@yahoo.com
FILE n
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Locke Bowden
PE-49704
Keystone Certifications, Inc.
04/22/2024
Diane Marotta, P.E.
Validation Checklist - Hardropy Received
FL28059 RD COI Product Reoort 1.0 Na'Ist ip 24GA Steel - SS odf
Standard Year
TAS 125 2003
UL 580 2006
Product Approval Method Method I Option D
Date Submitted 08/29/2018
Date Validated
Summary of Products
i
FL #
Model, Number or Name
Description
28059.1
Min..032" Aluminum 1.0 Nailstrip
Min..032" Aluminum 1.0 Nailstrip WITH SEALANT
WITH SEALANT
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-175
Other: - 175 PSF @6" O.C. Install per manufacturers
details and in compliance with FBC 2017. For HVHZ
application use RAS 133.
Installation Instructions
FL28059 RO II Product Report 1.0 Nailstrip 032 Aluminum
- S_S.Vdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL28059 RO AE Product Report 1.0 Nailstrip 03
Aluminum - SS.pdf
Created by Intlependent Third Party: Yes
28059.2
Min..032" Aluminum 1.0 Nailstrip
WITHOUT SEALANT
Min..032" Aluminum 1.0 Nailstrip WITHOUT SEALANT
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: -168.5 PSF @ 6" O.C. Install per manufacturers
details and in compliance with FBC 2017.
Installation Instructions
FL28059 RO II Product Report 1.0 Nailsc'p 032 Aluminum
-- 5
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL28059 RO AE Product Report 1,0 Nailstrip 032
Aluminum - SS odf
Created by Independent Third Party: Yes
28059.3
Min. 24GA Galvalume Steel 1.0
Nailstrip
Min. 24GA Galvalume Steel 1.0 Nailstrip
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: -206 PSF @ 6" O.C. Install per manufacturer's
details and in compliance with FBC 2017.
FL28059 RO it Product Report 1.0 Nallstrip 24GA Steel -
SS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL28059 RO AE Product Report 1.0 Nallstijo 24GA Steel -
SS.odF
Created by Independent Third Parry: Yes
28059.4
Min. 26GA Galvalume Steel 1.0
Nailstrip WITH SEALANT
Min. 26GA Galvalume Steel 1.0 Nailstrip"ITH SEALANT
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-176
Other: - 176 PSF @ 6' O.C. Install per manufacturer's
details and in compliance with FBC 2017. For HVHZ
application use RAS 133.
Installation Instructions
,FL28059 RO II Product Reoort 1.0 Nallst io 26GA
Galvalume - SS odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL28059 RO AE Product ReagEt 1 0 Nailst ' 26GA
Galvalume - 55 odf
Created by Independent Third Party: Yes
28059.5
Min. 26GA Galvalume Steel 1.0
Nailstrip WITHOUT SEALANT
Min. 26GA Galvalume Steel 1.0 Nailstrip WITHOUT SEALANT
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Installation Instructions
FL28059 RO IT Product Repot 1.0 Nailstrip 26GA
Galvalume - SS.odf
Impact Resistant: N/A
Design Pressure: +N/A/-116
Other: - 116 PSF @ 6" O.C. Install per manufacturer's
details and in compliance with F8C 2017. For HVHZ
application use RAS 133.
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL28059 RO AE Product Report 1.0 Nailst "0 26GA
Galvalume - SS odf
Created by Intlependent Third Party: Yes
Cbn= Us:: 2601 DlairSWne R d T II h FL 32399 Phene: 850d87-1824
Tha State of Florida is an aNtEO empbyer. Cnovriahf ]OW-20f3 sta0e of Florida :: Pdvad Statement :: �ibiliw Statement :: Lterund statement
UMu Florida law, ema0 addresses are public remr If you do trot want your e-mail address released in response w a public -rem request, do mts d elect k
mail l Nis entity. hvs0ead, f n . Ue onice by Phone or by traditional mail. ii you have any qugtlarts, please mndR a50.t t iM3 n •Pursuant m semen
4552]5(1), Florida StahrRs, eaeNve Oenber 1, 2012, li[ensr-� licensed uMv Uapter 555, F.S. mu# pmvido the Departrnenf wiN an emaJ add. If Ney have
one. The emails porvided may be used for official mmmunIadon wU Me licensee. However email addresses are public record. If you do not wish to wpply a
personal address, please ppyide the DepeNnent erid, an emml address which on be made available to die public To determine if you are a limosee under Chapter
40, F.S., please a icb hem.
Product Ppjpmmwal A
Credit Card
Safe
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec.1507.4.2
Yield strength: 40ksi: Attached to Wood Deck with screws.
16" Coverage
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate
3/16" thru 15/32" min. plywood deck
Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive
along male flange the full length of panel.
Underlayment: To be compliant with FBC Sec.1507
Slope: Shall be in compliance with FBC Sec.1507. 1.1
Install Details: Table Allowable Loads
MEiHODlmalnfie/d
METHOD2 perimeter
DESIGN PRESSURE*
-69.25 PSF
-121.75 PSF
FASTENER SPACING -ALONG ROWS
6" O.C.
61, O.C.
FASTENER SIZE:
#10
#10
ADHEISIVE:
NOT REQUIRED
3/8" BEAD (refer to
install details)
ncicreuce uaca: nueanit,ANE TEST LABORATORY, L.L.C. #TST ID:1527
Report#:0223-0313-02 TAS125-03(uL58o-o6iuL1897o4f)
Report#: 0223-1015-06 TAS125-03(uc 58o-o6luL 1897-o4f)
EQUIVALENCY., UL 2897.04 IS EQUIVALENT TO UL 1897.12 TESTSTANDARD *DESIGN PRESSURE MARGIN OF SAFETY2.1
r.eruncdce or maepenaence:
Locke Bowden, P.E. does not have, not will acquire a financial interest inranyld6wdany mar
under this evaluation. �;�� C. Bo"N,/',,''•, `L.Locke Bowden, P.E. is not owned, operated, or controlled by any �OL n- inaggfeRure� i
report. 1• .y.
d t mil/
-Of o
�` is PJ M
or distributing products
�7
products under this
Extreme Metal Fak (tors — Min..032" Aluminum 1.0 Nail Strip Panel
16" Wide Panel WITH SEALANT
Installation Details
Limitations: '
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 0 ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 eh ed., and per with Manufacturers installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
S. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6`h ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
PROFILE
FASTENER PATTERN ALONG VERTICAL SEAM:
FASTENED @ 6" O.C.
i' 16" O.C.
2320 sealant
Extreme Metal Fa:;g:4 ators — Min..032"
Aluminum 1.0 Nail Strip Panel
16" Wide Panel WITHOUT SEALANT
Installation Details
Limitations:
I. Underlayment to be compliance with current Florida Building Code (FBC)2017 a ed., see Chart 1507.2.1
2. Minimum slope to be compliant with Florida Building Code 2017 6u' ed., and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-1)
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
S. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6 h ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
PROFILE
FASTENER PATTERN ALONG VERTICAL SEAM:
FASTENED @ 6" O.C.
j 16" O.C.
l
FLORIDA PRODUCT APPROVAL
FLORIDA BUILDING CODE 2017
SX7RaG 7 METAL
FABRICATI CIS
Code Compliance:
The product herein has demonstrated compliance with the Florida Building
Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4
Product Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2027, as relates to Rule 61G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
Reference Data:
Testing: UL 580-06 Tests for Uplift Resistance of Roof Assemblies
Test Lab: Intertek-ATI Report #: G1195.09-450-44 Dated: 08/12/16
Testing: TAS125-03 Standard Requirements for Metal Roofing
Quality Assurance Entity:
Test Lab: Intertek-ATI Report #: G3443.36.450-44 Dated: 08/12/16
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2017, including Section
1515.2 and in accordance with manufacturer's recommendations.
Installation:
Install per manufacturers recommended details.
Underlayment:
Shall comply with Florida Building Code 2017 Section 1507, Table 1507.1.1
Roof Panel Fire Classification:
Any approved fire barrier having a current NOA. Fire classification is not part of
this acceptance.
Shear Diaphragm:
Shear Diaphragm values are outside the scope of this report.
Design Procedure:
For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs
outside the parameters listed on the load table, design wind loads shall be
determined for each project in accordance with FBC 2017 Section 1609 or ASCE
7-10 using allowable stress design. The maximum fastener spacing listed herein
shall not be exceeded.
,70NE2 ZONES
RIDGE
ZONE I
EAYE
ZONE2 GABLE ROOF
—RIDGE
ZONE
FL#
PRODUCTREPORT
Note: Dimension [a] is defined as 10% of the minimum width of the
building or as 40% of the mean height of the roof, whichever is
smaller.
Note: [a] cannot be less than either 4% of the minimum width of
the building or three [3] feet.
FLORIDA PRODUCT APPROVAL
FLORIDA BUILDING CODE 2017
=�7 EFVr r METAL.
FABRICATORS
1.0 Nailstrip .032" Aluminum WITH SEALANT
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1518.9,1523.6.5.2.4
Product Description:
1.0" Nailstrip .032" Aluminum Roofing Panel
Panel Material/Standards:
.032 Aluminum 0.028" MIN. To be in compliance with FBC 2017 Section
1507.4.3 Corrosion Resistant. Paint Finish (with approval) Optional
Panel Dimension(s):
As Tested: 16" Coverage Width
Fastener:
#10 x 1" panclip fastener through the nailstrip leg of the panel spaced 6" O.C.
Fastener goes through the nail strip panel and not the pre-existing nailstrip
slots.
The female leg of the panels snap -fit to the male leg of the adjacent panels.
Sealant:
Geocel 2320 Sealant — A continuous bead was used @ the nailstrip side of the
seam.
30# Asphalt saturated organic
A single layer was used with a 4" overlap between adjacent sheets.
felt paper:
Attachment — 0.120" x 1-1/4" galvanized annular ring shank roofing nails with
32GA tin caps spaced 6" o.c. at perimeter and overlaps, w/ 2 intermediate rows
spaced 6" o.c.
Fire Barrier:
A single layer was used with a 4" overlap between adjacent sheets.
Substrate Description:
15/32" 4-Ply CDX Plywood Sheathing
Attachment — use 8d coated ring shank nails spaced 4" o.c. over supports at 24"
o.c. maximum.
Design Uplift Pressures:
-175 PSF spaced @ 6" o.c.
FL#
PRODUCT REPORT
FLORIDA PRODUCTAPPROVAL
zzw n� FLORIDA BUILDING CODE 2017
FAB�Sf ;ATOFis
1.0 Nailstrip .032" Aluminum WITHOUT SEALANT
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4
Product Description:
1.0" Nailstrip .032" Aluminum Roofing Panel
Panel Material/Standards:
.032 Aluminum 0.028" MIN. To be in compliance with FBC 2017 Section
1507.4.3 Corrosion Resistant. Paint Finish (with approval) Optional
Panel Dimension(s):
As Tested: 16" Coverage Width
Fastener:
#10 x 1" panclip fastener through the nailstrip leg of the panel spaced 6" O.C.
Fastener goes through the nail strip panel and not the pre-existing nailstrip
slots.
The female leg of the panels snap -fit to the male leg of the adjacent panels.
Moisture Barrier:
Boral TileSeal — Self -adhered to the plywood roof deck.
30# Asphalt saturated organic
A single layer was used with a 4" overlap between adjacent sheets.
felt paper:
Attachment— 0.120" x 1-1/4" galvanized annular ring shank roofing nails with
32GA tin caps spaced 6" o.c. at perimeter and overlaps, w/ 2 intermediate rows
spaced 6" o.c.
Fire Barrier:
A single layer was used with a 4" overlap between adjacent sheets.
Substrate Description:
15/32" 4-Ply CDX Plywood Sheathing
Attachment— use 8d coated ring shank nails spaced 4" o.c. over supports at 24"
o.c. maximum.
Design Uplift Pressures:
-168.5 PSF spaced @ 6" O.C.
FL#
PRODUCTREPORT
IRIDA PRODUCT APPROVAL
RIDA BUILDING CODE 2017
Product Report
EXTREME METAL FABRICATORS, LLC
1.0" Naiistrip .032" Aluminum over Min.15/320 4-Ply CDX Plywood
Florida Product Approval #
Florida Building Code 2017
Per Rule 61G20-3
Method:l-D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005 (1)(d)
WITH SEALANT: HVHZ
WITHOUT SEALANT: NON-HVHZ
Product Manufacturer:
Extreme Metal Fabricators LLC
21505W Poma Drive
Palm City, FL 34990
Engineer Evaluator:
Locke Bowden, P.E. # 49704
9450 Alysbury Place
Montgomery, AL 36117
Va6dator:
Diane G. Marrotta, P.E. #82591
1915 NE 451 St. #107
Fort Lauderdale, FL 33308
Contents:
Product Report
Certificate of Independence:
Locke Bowden, P.E. does not have, nor will acquire a financial interest in any company manufacturing or distributing products under
this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer or distributing products under report.
FL#
PRODUCT REPORT
FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6a' ad..
2. Minimum slope to be compliant with Florida Building Code 2017 6a' ad., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4: Engineering analysis for "project specific approval by local authorities wfiurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6U ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Fastener.
+la Pancake -Head
- `-- anti' Bead Scsrtnad�v
-1S3-T `Aood Dedt own nu amrT aVe rib
(Rder OTable'A5
I6" O.C.
Wood Deck
integral Snap Lock
Seam Adhesive
Apply 3/8" bead Bosfik Sealant
entire length of panel
along male flange
:1Dx 1"
Pancake -Head Scre%�
dFlorida
y K.� pr
,..ecrr.::i
BCIS Home wgN User Begls Uon j Hot TOPi6 i
j-Suy^ Product Approval
USE0.. Pubac User
i1a5-oSly
u
V>_
Subma Sumhmge SUM&Fams Publig.. ContaR Us BC651@Map ❑nl¢' Seamb
iz a > P -n er APO at'on 5 > Aoolirat on UNt> Appliraeon Detail
FL *
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL36048-116
Revision
2017
Approved
rK
Tri-Bullt Materials Group, LLC
PO Box 70
Rutherford, NI 07070
(800) 516-1485
david.rulz@tribuiltmg.com
David Ruiz
davi d.ruiz@tribuiltmg.mm
SCASY ED
St. Lucie County
RECETVED
MAY
Sr. LuG19 Sgunty, P^.rn,ittln9
David Ruiz
250 Route 17 North
East Rutherford, NJ 07
(201) 842-2449
david.roiz@tribuiitmateria ICI
m
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardmpy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
Li Validation Checklist - Hardcopy Received
FL16048 R6 COI 2917 01 COI Nieminen ndf
Standard
ASIM D1970
ASTM G155
FM 4474
FRSA/rRI April 2012 (04-12)
UL 1897
y
2015
2005
2011
2012
2012
Product Approval Method Method 1 Option D
Date Submitted 09125/2017
Date Validated 10/012017
Date Pending FBC Approval 10103/2017
Date Approved 12/12/2017
Summary of Products
r��l
FL Af
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: NO
FL1604B R6 H 2017 09 FINAL ER TRi
Approved for use outside HVHZ: Yes
BSIILT (INDERLAYMFNTS 16046-R6 df
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Parry: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop the self -adhering
FL1604B R6 AE 2017 09 FINAL R TRi
underlayment for one particular application. See ER Section
BUILT UNDERLAYMENTS 16048-R6 df
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Parry: Yes
Use.
Contact Us:: 2601 Bah Shoo Road. TllM1sse= ft 323" phone: 85h-0R7-1824
The Stale of Florida Is an AAXW employes coovdbht 2007-2013 State of rddda.:: Pdvicv Statemem:: A¢e Milite St aement ;: Rafted Statement
Under Florida law, email add —are public recoMs. If you do not want your a -mail address releasM in response to a pub4o-recoms request, do not send electronic
mail to this entity. instead, contact Me office by phone or by traditional mall. nyou have any questions, please coned 850.487.1395. 'Pursuant to Section
455.275(1), Honda SMtutes, effective October 1, 2012, licensees ficame0 under chapter 455, F.S. must provide Me Department with an email address If they have
outsideone. The outside provided may be used for official communiotion with Me hoensee. However email addresses are public record. If you do net wish M supply a
personal add., please provide Me Department with an email address, which can be made available M Me public To determine if you are a licensee under Chapter
455, RS., please dick here .
Produtt Approval Accepts:
fjj�l99® °=-1 RE