Loading...
HomeMy WebLinkAboutPRE BUILDING PERMIT ADDENDUMSMATHERS ENGINEERING CORPORATION RECEIVED AUG 2 3 2018 ST. Lucie County, Permitting 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#004456 TE. 2 t� � (gyp(9'��F� PRE -BUILDING PERMIT ADDENDUM PILE COPY Date: August 09, 2018 To: St. Lucie County Building Department SCANNED 2300 Virginia Avenue BY Fort Pierce, FL 34982 St. Lucie County Referenced Project: Concrete Restoration for Exterior Balconies For Building #3 Unit Numbers 3 •A, 3-B, 3-C, 3-D, 3-E, 3-F, 3-G, 3-H, 3-I, 34, 3-K and 3-L. For Villa Del Sol Condominium Located at 11000 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: Blue Coast Construction 2587 SE Monroe Street Stuart, FL 34997 Enclosed is a copy of the structural threshold license for William J. Mathers, P.E. as the threshold inspector for the project referenced above in accordance with Florida Statutes 553.79. Sincerely, 111111//�� pENS�c • �F,p� =19658 TATE OF William J. Mathers, PE Florida License #19658 0 ��i �FSS ONA Special Inspector FL License #SI-15�Lj�///11 ALA r Y• 4 da Sta Boar KSW e4 �iLeers t tl�. 9© � � A s Q e C • r. r,,. , i r,�9 are • 11 B PE Is licensed as a Profes .q11 _)_'1 �0'_ i 1 /ter471, Florida Expiration: 1Gf,Il oil � P. � � , ._ " I 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 MATHERS ENGINEERING EB#004456 CORPORATION RECEIVED PRE -BUILDING PERMIT ADDENDUM SCANNEU AUG 2 3 2018 Date: August 09, 2018 BY St. Lucie Counts ST. Lucie County, Permitting To: St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Referenced Project: Concrete Restoration for Exterior Balconies For Building #3 Unit Numbers 3-A, 3-B, 3-C, 3-D, 3-E, 3-F, 3-G, 3-H, 3-I, 3-J, 3-K and 3-L. For Villa Del Sol Condominium Located at 11000 S. Ocean Drive, Jensen Beach, FL 34957 Contractor: Blue Coast Construction Tie P—V"�'1+�'j3C)8 -o60oG 2587 Monroe Street FILE COPY Stuart,Stua, FL 34997 Background: The removal and restoration of deteriorated concrete and steel within beams, columns, decks and adjacent walls will comply with the IRCI Guideline No. 03730 (a copy of which is attached hereto) or as modified by Engineer as work progresses. The anticipated work involves the initial demolition, and then the removal, replacement and restoration of concrete and reinforcement as required. The degree of restoration is currently unknown, until such time as the initial demolition has begun. The anticipated sequence of repairs, is as follows: • Shoring required for repairs of all columns, beams and decks (if required by engineer) • Removal and restoration of concrete and reinforcement steel within beams, columns and decks. (ICRI Guideline No. 03 73 0) • Minor chipping and patching of areas not requiring full depth repairs. • Applied deck coating. The following materials are approved for anticipated use in this restoration (see attached manufacturers specifications): • Sikacrete 211 Concrete Mix. • SikaTop 123 PLUS. • Sika Armatec 110 EpoCem bonding agent and rebar coating. • Sika FerroGard 903. • Sikagard 701 W. • Neogard Decorative Peda-Gard The above sequence is general in nature and will be modified as restoration work progresses. Observations of the initial demolition will determine any required modifications to the above procedures and materials selected for the final restoration process. OWN MATHERS ENGINEERING CORPORATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#004456 Based on initial visual observations, repairs will not require shoring; however, in the event the demolition work reveals that shoring will be required, the engineer will instruct the contractor to shore the area as weltas the number of levels required. The instructions given to the contractor will be submitted to the Building Department with the final close-out documents. We have been authorized by the Association to work with the contractor during the restoration and, will inspect work partially completed as well as observe results of the new demolition prior to field authorizing the repairs to be completed. The proposed concrete restoration work, except as authorized by the engineer's modified instructions, will comply with specifications outlined in the IRCI Guideline No. 03730, as well as the applicable minimum building codes and the applicable fire safety standards as determined by the local authority in accordance with Chapter 553 and Chapter 633 of the Florida Statutes where applicable to concrete restoration. Approved, \\\I111J II/ E 19658 STATE OF .Q� William J. ers, PE Florida License /SS/ONA I111 „���� Special Inspector FL License #SI-155 `A