Loading...
HomeMy WebLinkAboutENGINEERING TESTING - FIELD DENSITY TEST�11F-P A 1, ';�-'18 AGORA CIRCLE S.E. SUITE 5 'LM BAY, FLORIDA 32909 FIELD DENS ' FTE I M I DATE: 03/05/04 OJEMC�-z CLIENT: B & D GRADING, WC. I St. Lucie 250 S.W. 13TH AVENUE POMPANO BEACH, FLORIDA 33069 SGANNED SOILS BY St. Lucie Coun PERMIT NO. 9 Y010 46 & ADDRESS: ' 2790 COOLIDGE ROAD, fORT PIERCE, FLORIDA 34945 PROJECT:— PROPOSED RESIDENCE BUILDING PAD CASTLE PINES ADDRESS:— PGA VILLAGE BUILDING 49, PORT ST. LUCIE, FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND W/SOME CLAY & TRACES OF SHELL FRAGS LOCATION:- N.E. CORNER OF PAD LOCATION:— S.W. CORNER OF PAD LOCATION:— S.E. CORNER OF PAD T nCA FIELD DENSITY METHOD A-S.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 109.0 108.9 108.2 • MOISTURE 7.0 6.2 .7 • COMPACTION IN THE FIELD 98.6 98.5 97.9 • COMPACTION REQUIREMENT BY SPECS 95% PROCTOR VALUE, P.C.F. 110.6 OPTIMUM MOISTURE, % 10.5 LABORATORYNO. P-1530 DEPTH IN INCHES 12 PROCTOR A.S.T.M D-1557 METHOD ALL TEST RESULTS COMPLY WITH SPECIFICATIONS UNLESS OTHERWISE NOTED WITH AN ASTERISK(*). REMARKS:— SOIL NOT TESTED BELOW FOOTINGS '��STEDBY: SL ,�`IECKED BY: WN As a mutual protection to clients, the public and ourselves� all reports are submitted as the confidential property of clients, and authorization for publication ofstatements, conclusions or exu-4cts fimm or regarding our reports is reserved pending our written approval. Respectfully submitted. J J5 5 ,--Oft'SAMS.�fto P.E. FEDERAL ENGINEERING & TESTING FLORIDA REG. #39584 '