HomeMy WebLinkAboutCARPORT PLANSI REINFORCED FOOITR 2 5" PLAN VIEW BUILDING FRAMING-7 J" RECESS------.. 7�_k "�L__UOOIR WIDTH-------� ELEVATION VIEW BUIL ING FRAMING RECESS--- -7 —4� DOOR WIDTH ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS 4"x5j" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END -WALL POST 2" MINIMUM SOIL BEARING CAPACITY 2,000 PSF (TYP.) RAIL 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. OR FIBER MESH (2) #5 RESAR 0 6" O.C. CONTINUOUS WITH MINIMUM 12* OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL - I ANCHOR D TAIL_ NOTES - SUB —GRADE SOILS, —TO BE TERMITE TREATED AND COVERED WITH 6 M11 VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION CONCRETE- -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCIUG STEEL (REBAR) REQUIREMENTS, —MINIMUM GRADE 40 STEEL —REBAR MAY HE BENT IN SHOP OR WIELD PROVIDED: —THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 5—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF I" HORIZONTALLY TO 6" VERTICALLY. —COVER: —2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 14' ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF I" FOR FINE GROUT. AND " FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL REELAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 1j" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION, —METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GArV41ZED. PSI e CONCRETE SLW3 WITH W.W.F. (OR FIBER AND 12�x12" RONFORCED F007R PERIVEIER MAY 2 3 '119 ST. Lucie County, SCANNED BY St. Lucie CoUntv E��� REVIEWED FOR CODE COMPLIANII ST. LUCIE COUN7 BOCC 10 1 10 a 1 0 I MOE VERSION IFBC W17 Oth 05W� AKE-7-101 1 BUILD No 1��' MMMI TYPE 'ON ZE SUOPECISIIN SYSTEM JOCCURANCY ENCLOSURE JOOF DEAD LOM I0PSF ME VIE UOM 2.PEF OR 3OOI� PONT LOAD ,on, to.2.!' W'SF RATING OF WAU_S. FUWR. ROOF N/A 7IODULES PER BUILDING I NOR SHEL LR UWE 0 SMEtFE)CIAGETE 17100 so. FL REVISIONS MTB H,. 3/20/19 5701 Sucharar, Dr., Ft. Pierce. 34982 70'L X 30'W X 14'H 1.15 BUILDING 0 DEMPT FROM THE Woo ENERGY' CONSERVATION CODE PER SECTION C101.4�. � STHE_ TOTING S�OLL, BE 50 WO STI PLUMBING, FLFCTRIC� INGRESS/ECRESS, PROPERTY sET_S0XHS. AND/CR OTHER UDtA_ CODE REWIRWEN75 ME Ole RESPONSiXUffY OF NE OWNER. RODF AND WAL. SHEA7H;NC SECURED 'EUF-QRIUU1G SCREWS WITH SE& WASHERS 0 6' O.C. NAX FIELD PRIWNG OVINKECTIONS SECURED WITH #12-14x3/4' SELF-DRIUUNG DORM. �L SHOP FR-UNG CONNECTIONS ME TO BE WEUDED. NO WELDING ONSIDE. ALL WC_DIN. DONE IN SHOP. CONCRETE DORANSIONS MOTORS ME TO BE MINIMUM 1/2'.3'. MOULD TENST_E STRENGTH. 12 OR 14Gk FRAWING IS 2-5',Q.5­ TUBI STM_. N.,FPLES xl� E m Li > t a— aldwin P.E. Florida License #64608 < 1160 Pn�lv R�d. D�nd. R. U720 __j C__ Sheet: CA-1 OF 4 MINIMUM 6" I'S NIPPLE. NIPPLE SECURED TO WAUL POST WITH X)#12-I4,j' SELF -DRILLING SCREWS POST TO BASF RAIL CONNECTION MINIMUM 6' TS NIPPLE. NIPPLE SECURED TO WAL, POST WITH (4)&12-i4,,T SOLF-011WRIG SCREWS 2%2�2' 16 Gk ANGLE CLIP 2*X2*a* 16 GA. ARGUE CLIP SECURED SECURED WITH (4) #12-144- WITH (4) #12-14,d' 5EU`-DRA_UNG 16 GA. ANGLE CUP SECURED SELF-ORR.L.NG SCREWS SCREWS I � 1 2: WITH 141 #12-144' SELF-DRIWNG SCREWS S%GLE OR COURTS IS HEADER INTERMEDIATE POST TO - END POST TO BASE RAIL HEADER/E3ASF RAIL/OR HEADER. CONNECT ION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 1 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi- SELF -DRILLING 16 GA. ANGLE CLIP WITH (4) #12-144- LUNG SCREWS NON-STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL -- MAX. MAX. MIN. SIDE WALL ROLL -UP DOOR HEADER DETAIL 25 GAUGE ROOF SHEADANG SECURED WITH (1)#12-tA4' SELF-DRLUNG SCREWS 0 6' DID. Is" D.C. MAX.) 1" 16 GAUGE FURRING CHANNEL 48- OC� VAX_ SECURED WITH (2)#12-14xl' SELF -DRILLING SCREWS TO EACH RAFTM ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION MINIMUM 6" IS GPPUE- NIPPLE TO WALL POST WITH 4,j- SELI'-DRIWING SCREWS OR DOUBLE IS HEADER HEADER CONNECTION DETAIL OPTION 2 NIPPLE MINIMUM 6' IS NIPPUE- NIPPILZ SECURED TO WALL POST if," (4)112-14,4- SEUF-DRILUNG SCREWS POST TO TRUSS CONNECTION J12-141j' SELF -DR -LUNG NSTA� PER MANUFACTURERS INSTRUCTIONS 2 bl4xl� SELF -DRILLING SCREWS 0 61 Q�C. MAX. NIPPLE Td\1A:L TRU&S� V\ 26 Glk. RIDGE CAP SCREWS 0 10' O.C_ MAX, 3" IF MAX. MOM CORNERS MAIL FROM CORNERS HORIZONTALLY/ 4" MAX. MOM CORNERS VMMALLY 4 15 Gk U-CHANNEL BRACE, MIN. 24- UP TO 7' POR7, Mft 48� YlER 7' POST. MIN. 16 GA. ROOF 4u TO MAX 67 MOM SHEATHING INTEROR EXTERIOR A, FIORIZ. (EXCLUDE END -WALLS 26 GAUGE ROOF SHEATHING SECURED M;NIMUM 6' TS NIPPLE. NIPPLE \ h, ANIMUM 24* Ts NIPPm """A S, Nep., SCREWS a 9, D.C. 14M 91" -.1 SECURED TO WALL POST WITH (4)#t2-I4,j- SELF-DRILUNG SCREWS DOOR FRAME TO POST ROLL -UP DOOR TO BOX EAVE RAFTER TO TRUSSED RAFTER ROOF RIDGE CAP CONNECTION POST CONNECTION DETAIL -POST CONNECTION CONNECTION DETAIL REINFORCEMENT DESIGN PRESSURES — 160 Mph ROOF +22.0/-48.4 WALLS +25.4/-22.8_ DOORS +25.4/-22.8_ WINDOWS +25.4/-22.8 1 2 3 1 4 1 5 ZONE + 11.7 —25.8 +14_3 —39.1 +22.0 —48.4 +25.4 —22.8 +23.8 —20.1 APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY I'Ll 7996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION I'Ll 2765.4 SERIES 3100 WINDOW MI WINDOWS AND DOORS I'Ll 7499.1 —R2 MODEL 185 SH 2017 69, Edrimm. rRucTioN �E CATEGORY' PROTECTION SUPPRESiSION SPEED INTERNAL PRESSURE COEFFICIENT I- a'. IMPORTANCE FACTOR 1.15 ROOF DuW LOAD 1.11 ROOF URE LOAD Tlj�.R . -.1w I... FLOOR DEAD LOAD FLOOR UW LOAD Cos, 'R" RATING OF WALLS. PUGOR� ROOF N/A MODULES PER BUILDING I HURRICANE PROTECTION USAGE NO -- HURRICANE SHELTER USAGE 1SQUARE FOOTAGE 12,100 50. FT. V.TB 5701 B.chanon Dr., F',. Pie,ce, 34982 701 X 30*W X 14'H SEF-SADRS, ANG/GR OTHER LOCAL MOE REXIOREMENTS ME pe RESPONSIBILITY or THE O^ER. Boor AND WALL S.�I.N�'SECURED WITH #12-14xl' SEUF-DRIUJNG SCREWS WITH SEAL. WASHERS 0 6' D.C. MAX. FELD FRAMING CONNECTIONS SECURED WITH #12-14xs/e SELF-DRILUNG SCREWS. ALL SHOP FRAMING CONNECTIONS ARE TO BE WEUUEa NO WELDING ONSDE. ALL WELDING GORE IN SHOP - CONCRETE SlPANVONS ANCHORS ME TO BE M NIMUM 1/2�ll'. 2.50013 TENSILE STRENCRA. 12 OR HIGX FRAMING 6 2.5,UL5' TUBE STI RIPPLES I 3/23/19 Matthew T. Baldwin P.E. Florida License #64608 1160 Priveh, ftm. DvWnd. FL 32720 Sheet: CA-4 OF 4