HomeMy WebLinkAboutEVALUATION REPORTCREEK
TECHNICAL SERVICES, LLC
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6�
EDITION (2017)
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657
SCANNED
(800) 438-7465
www,owenscoming.com
BY
SCANNED
Manufacturing Location:
Brentwood, NH
St.,LudeC0UY1W
BY
Houston, TX
It wcieft*
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1.1507.1.1
Properties:
Physical properties
REFERENCES
Enti
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST5878)
NEI-039-02-01
ASTM D 1970
2015
PRf Construction
Materials Technologies (TST5878)
NEI-042-02-DIREV2
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
FRI Construction
Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction
Materials Technologies (rST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction
Materials Technologies (TST5878)
NEI-093-02-02
ASTM 0 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction
Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
OR] Construction
Materials Technologies (TST5878)
DCF-252-02-01
ASTM D 1970
2015
PRI Construction
Materials Technologies (rST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 188'
2012
ICC-ESAC48
2012
PRI Construction
Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF�318-02-01
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction
Materials Technologies TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction
Materials Technologies TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST5878)
OCF-355-02-01
UL 180
2012
'Determined to be equivalent to ASTM D 226-09, Type I
and 11
OCRI4002.8a FL9777-Rll Pane I of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer- shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recornmended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockO Self,%aling Ice & Water Barriers
WeatherLocko G
WeatherLock(D G is an ASTM D 1970 self-adhesive uncleflayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced With granules. The
product is supplied In 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
Weathert-ock(D G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days,
WeatherLockO Mat
WeatherLockO Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwoccl� NH or
SBS modified asphalt with a fiberglass mat reinforcement The product is supplied in 1-
Houston, DO
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
Weatherl-ock(l) Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLockS Metal
WeatherLock@ Metal Is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLockS
WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive undedayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied In 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, T)Q
WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONDP Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete file installations
without battens. Tile shall be stared on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
Weatherl-ocklD G (High
WeatherLock@ G (High Tear) is a self�aclhared, undadayment used as an alternative to
Tear)
ASTM D 226, Type I or Type 11 roofing felt and ASTM D 1970 self -adhering polymer
(Houston,
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat Internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
WeatherLockO G (High Tear) Is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
1 ------- r LUI ( f -M I I Page 2 of 4
Zis e�a ,alon,= provided for State of Florida product approval under R5ie 61 G20.3. The manufacturer shall notify CREEK
hn'cal' ery of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty. installation. recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TFcHNICAL SERVICES� ILLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatfierLock(D Self -Sealing Ice & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: Ali undertayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked.forprotrusion and corrected prior to underlayment
application. Prior to beginning installation, the underfayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
Into place to ensure complete contact with the deck. The undeflayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered min, 6-ft.from preceding course. Additionally, if
applying WeatherLockO Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It Is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads gush to the top surface of the
underlayment). Additionally, Weatherl-ock(D Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40OF; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FEIC Section 1504.9
Undedayment System No.1 — Weathert-ock S-Dedaltv Tile & Metal OnIv
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Undeflayment: WeatherLock@ Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnalled along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underiayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-Rll Page 3 or 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock& Self -Sealing Ice & Water Barriers
I ) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seems shall be Installed to shed water from the deck.
7) The undertayment may be used as described in other current FBC product approval documents.
8) Design Mind load pressures shall be determined for components and cladding in accordance with FBC:
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R
..........
No 74021
411
STATE F Z
�0 �4(f
...........
%
CERTIFICATION OF INDEPENDENCE
2017.10.1
09:06:29
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, RE does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product
END OF REPORT
OCR14002.8a FL9777-Rll Page 4 of 4
evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufactur shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that am not
specifically addressed herein.