Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 W: I He Copy FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES- 2508 CR MODEL Builder Name: ADAMS HOMES SCANNED Street: 8504 WATERSTONE BOULEVARD Permit Office: ST LUCIE COUNTY BY CityrState.Zip: FORT PIERCE, FL, Permit Number: Omer: Jurisdiction: ST LUCIE COUNTY St. Lucie County Design Location: FL, Fort Pierce County., St. Lucie (Florida Climate Zone 2 ) 1i New construction or eAsting New (From Plans) 9. Wall Types (2038.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1794.00 ftz b. Frame - Wood, Adjacent R=11.0 244.00 ft2 3. * Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2508.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2508.00 ft- 6. Conditioned floor area above grade (W) 2508 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 11. Ducts R ft2 7. Windows(271.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 200 a. U-Factor: SgI, U=0.65 218.00 ft2 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.70 53.33 W 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.30 a. Central Unit 47.0 SEER:15.00 c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: NIA ft, a. Electric Heat Pump 34.0 HsPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons B. FloorTypes (2508.0 scift.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2508.00 W b. Conservation features b. N/A R= fI2 None c. NIA R= ft� 16. Credits None Glass/Floor Area: 0.108 Total Proposed Modified Loads: 73.64 PASS Total Baseline Loads: 75.95 1 hereby certify that the plans and specifications covered by Review of the plans and 11 this calculation are in compliance with the Florida Energy specifications covered by this g Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 4-29-1 U this building will be inspected for compliance with Section 553.908 I t�ereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code WE OWNER/AGENT: BUILDING OFFICIAL: DXTE: 41 7 t?1--- DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/29/2019 11:44 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ADAMS HOMES- 2508 CR M Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2508 Lot # Omer Name: Total Stories: 1 Block/SubdiAsion: # of Units: I Worst Case: No PlatBook: Builder Name. ADAMS HOMES Rotate Angle: 0 Street: 8504 WATERSTONE B Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie -Jurisdiction:— ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE-,___ Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE *V Design Temp Int Design Temp Heating Design DailyTernp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume Entire House 2508 22072 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated I OWIC1 44 352 No 0 1 Yes Yes Yes 2 OWIC2 45 360 No 0 1 No Yes Yes 3 0 BATH 119 952 No 0 1 Yes Yes Yes 4 LIVING ROOM 182 1456 No 0 1 Yes Yes Yes 5 FOYER 72 720 No 0 1 Yes Yes Yes 6 DINING ROOM 169 1690 No 0 1 Yes Yes Yes 7 FAMILY ROOM 542 5420 No 0 1 Yes Yes Yes 8 BREAKFAST 65 650 No 0 1 Yes Yes Yes 9 HALLWAY 85 680 No 0 1 No Yes Yes 10 KITCHEN 156 1560 Yes 0 1 No Yes Yes 11 HALL2 52 416 No 0 1 No Yes Yes 12 LAUNDRY 73 584 No 0 1 No Yes Yes 13 AHU CLST 15 120 No 0 1 No Yes Yes 14 BATH 2 45 360 No 0 1 No Yes Yes 15 CLST 2 22 176 No 0 1 Yes Yes Yes 16 BEDROOM 2 143 1144 No 0 1 1 Yes Yes Yes 17 BEDROOM 3 132 1056 No 0 1 1 Yes Yes Yes 18 CLST 3 21 168 No 0 1 Yes Yes Yes 19 CLST 4 14 112 No 0 1 Yes Yes Yes 20 BEDROOM 4 143 1144 No 0 1 1 Yes Yes Yes 21 BATH 3 98 784 No 0 1 Yes Yes Yes 22 0 TOILET 24 192 No 0 1 No Yes Yes 4129/2019 11:44 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 7 FQR� R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 23 OWNERS BEDRO 247 1976 No 0 1 1 Yes Yes Yes FLOORS V# FloorType Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation owici 9 it 0 44 ft2 ---- 1 0 0 - 2 Slab -On -Grade Edge Insulation OWIC2 I it 0 45 ft2 ---- 1 0 0 3SIab-On-Grade Edge Insulation 0 BATH lift 0 119 ft2 ---- 1 0 0 4SIab-On-Grade Edge Insulation LIVING ROOM 32ft 0 182 W ---- 1 0 0 — 5SIab-On-Grade Edge Insulation FOYER 8 it 0 72 ftz 1 0 0 — 6 Slab -On -Grade Edge Insulation DINING ROOM 14 it 0 169 ft2 ---- 1 0 0 - 7 Slab -On -Grade Edge Insulation FAMILY ROOM 18 ft 0 542 ft- ---- 1 0 0 — 8SIab-On-Grade Edge Insulation BREAKFAST 9ft 0 65 ft2 - - - 1 0 0 9SIab-On-Grade Edge Insulation HALLWAY ift 0 85 it- 1 0 0 — 1 0SIab-On-Grade Edge Insulation KITCHEN ift 0 156 ft2 1 0 0 — 1 ISIalb-On-Grace Edge Insulation HALL2 ift 0 52 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 73 it' 1 0 0 13SIab-On-Grace Edge Insulation AHU CLST ift 0 15 ft2 1 0 0 - 14SIab-On-Grace Edge Insulation BATH 2 ift 0 45 ft2 1 0 0 - 15SIab-On-Grade Edge Insulation CLST 2 2ft 0 22 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 2 13 it 0 143 1`0 ---- 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 3 12 It 0 132 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation CLST 3 3ft 0 21 ft2 ---- 1 0 0 IgSlab-On-Grade Edge Insulation CLST 4 2ft 0 14 ft- ---- 1 0 0 20SIab-On-Grade Edge Insulation BEDROOM 4 24 ft 0 143 112 ---- 1 0 0 - 21SIab-On-Grade Edge Insulation BATH 3 14 it 0 98 ft2 ---- 1 0 0 22SIab-On-Grade Edge Insulation OTOILET Ift 0 24 ft2 ---- 1 0 0 2351ab-On-Grade Edge Insulation OWNERS BEOR 41 It 0 247 ft2 ---- 1 0 0 4/2912019 11:44 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF v Roof Gable Roof Solar SA Emift Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2805 ftz 0 ft2 Medium 0.6 No 0.9 No 0 26.6 ATTIC v# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2508 ft2 N N CEILING V# Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type - 1 Under Attic (Vented) OWIC 1 30 Blown 44 ft- 0.1 Wood 2 Under Attic (Vented) OWIC2 30 Blom 45 ft2 0.1 Wood - 3 Under Attic (Vented) 0 BATH 30 Blom 119 ft2 0.1 Wood 4 Under Attic (Vented) LIVING ROOM 30 Blom 182 ft2 0.1 Wood - 5 Under Attic (Vented) FOYER 30 Blown 72 ft- 0.1 Wood 6 Under Attic (Vented) DINING ROOM 30 Blown 169 ft2 0.1 Wood 7 Under Attic (Vented) FAMILY ROOM 30 Blom 542 W 0.1 Wood - 8 Under Attic (Vented) BREAKFAST 30 Blown 65 ft2 0.1 Wood 9 Under Attic (Vented) HALLWAY 30 Blom 85 ft, 0.1 Wood - 10 Under Attic (Vented) KITCHEN 30 Blom 156 ft- 0.1 Wood 11 Under Attic (Vented) HALL2 30 Blom 52 ft2 0.1 Wood 12 Under Attic (Vented) LAUNDRY 30 Blown 73 ft2 0.1 Wood 13 Under Attic (Vented) AHU CLST 30 Blom 15 ft2 0.1 Wood 14 Under Attic (Vented) BATH 2 30 Blown 45 ft2 0.1 Wood 15 Under Attic (Vented) CLST 2 30 Blown 22 ft' 0.1 Wood - 16 Under Attic (Vented) BEDROOM 2 30 Blown 143 ft2 0.1 Wood 17 Under Attic (Vented) BEDROOM 3 30 Blown 132 ft2 0.1 Wood - 18 Under Attic (Vented) CLST 3 30 Blom 21 ft- 0.1 Wood 19 Under Attic (Vented) CLST 4 30 Blown 14 ft- 0.1 Wood 20 Under Attic (Vented) BEDROOM 4 30 Blom 143 ft- 0.1 Wood 21 Under Attic (Vented) BATH 3 30 Blown 98 ft2 0.1 Wood 22 Under Attic (Vented) 0 TOILET 30 Blom 24 ft- 0.1 Wood 23 Under Attic (Vented) OWNERS BEDR 30 Blown 247 ft2 0.1 Wood WALLS V Adjacent CaAty Width Height Sheathing Framing Solar Below 9 nrnt T� IA/nll Type Space PA/A.'. Pt In Ft In A,,, P-Vnhip Pr�finn Alh�or rrndp0l. 1 S Exterior Concrete Block - Ext Insul 0 WIC 1 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 2 S Exterior Concrete Block - Ext Insul 0 BATH 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Ext InsLIJIVING ROO 4.1 5 0 a 0 40.0 fF 0 0 0.6 0 4 E Exterior Concrete Block - Ext InsL111VING ROO 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Ext InstHIVING ROO 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block - EA Insul FOYER 4.1 8 0 10 0 80.0 ft. 0 0 0.6 0 4129/2019 11:44 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS V ft O�f Adjacent T, WAII Tvpp Space Cavity Width Pt In Height Ft 1� A- Sheathing Framing F,,,M, Solar Ah��, Beim rr,vi,PA - 7 E Exterior Concrete Block - Ext Ins(NNING ROO 4.1 13 0 10 0 130.0 It' 0 0 0.6 0 - 8 S Exterior Concrete Block - Ext InsOINING ROO 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 - 9 N Garage Frame - Wood DINING ROO 11 2 0 10 0 20.0 ft' 0 0.25 0.6 0 _10- W Exterior Concrete Block - Ext InsdRAMILY ROO 4.1 18 0 10 0 180.0 ft- 0 0 0.6 0 11 SW Exterior Concrete Block - Ext InstBREAKFAST 4.1 5 0 10 0 50.0 W 0 0 0.6 0 12 W Exterior Concrete Block - Ext InstBREAKFAST 4.1 4 0 10 0 40.0 ft- 0 0 0.6 0 _ 13 E Garage Frame -Wood LAUNDRY 11 8 0 8 0 64.0 f? 0 0.25 0.6 0 14 N Garage Frame -Wood LAUNDRY 11 2 0 8 0 16.0 ft2 0 0.25 0.6 0 15 E Garage Frame -Wood BATH 2 11 5 0 8 0 40.0 ft- 0 0.25 0.6 0 16 N Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 8 0 16.0 ft, 0 0 0.6 0 17 E Garage Frame -Wood CLST 2 11 11 0 8 0 88.0 W 0 0.25 0.6 0 18 S Garage Frame - Wood CLST 2 11 2 0 8 0 16.0 ft- 0 0.25 0.6 0 19 N Extenor Concrete Block - Ext InsiBEDROOM 2 4.1 13 0 8 0 104.0 ft- 0 0 0.6 0 20 N Exterior Concrete Block - Ext InstSEDROOM 3 4.1 12 0 a 0 96.0 ft- 0 0 0.6 0 21 N Exterior Concrete Block - Ext Insul CLST 3 4.1 3 0 8 0 24.0 ft2 0 0 0.6 0 22 N Exterior Concrete Block - Ext Insul CLST 4 4.1 2 0 8 0 16.0 ft- 0 0 0.6 0 23 N Exterior Concrete Block - Ext InstSEDROOM 4 4.1 13 0 8 0 104.0 ft- 0 0 0.6 0 24 W Exterior Concrete Block - Ext InsiBEDROOM 4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 25 S Exterior Concrete Block - Ext Insul BATH 3 4.1 5 0 8 0 40.0 ft- 0 0 0.6 0 26 W Exterior Concrete Block - Ext Insul BATH 3 4.1 9 0 8 0 72.0 W 0 0 0.6 0 27 N Exterior Concrete Block - Ext InsWWNERS BE 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 28 S Exterior Concrete Block - ExI InsQWNERS BE 4.1 18 0 8 0 144.0 ft- 0 0 0.6 0 29 W Exterior Concrete Block - Ext InsOWNERS BE 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 DOORS V Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In E Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V, # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 S 2 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None - 2 E 4 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in I ft 4 in None None - 3 S 5 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft- 2 It 0 in 1 ft 4 in None None - 4 E 7 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft- 2 ft 0 in 1 ft 4 in None None - 5 W 10 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2ft0in I ft 4 in None None 6 W 10 Metal Low-E Single Yes 0.7 0.3 N 17.8 ft2 2 ft 0 in 1 ft 4 in None None - 7 SW 11 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft- 2 ft 0 in 1 ft 4 in None None - 8 W 12 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None - 9 N 19 Metal Low-E Single Yes 0.65 0.25 N 15.0 f? 2 ft 0 in 1 ft 4 in None None 10 N 20 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None - 11 W 24 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in I ft 4 in None None 4/29/2019 11:44 AM EnergyGaug0i) USA Section R405.4.1 Compliant Software Page 5 of 7 FOR� R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. v # Wall Orm ID Frame Panes NFRC Overhang U-Factor SHGC imp Area Depth Separation IntShade Screening — 12 — 13 — 14 S 25 Metal Low-E Single N 27 Metal L=-E Single W 29 Metal Low-E Single Yes Yes Yes 0.7 0.3 N 17.8 W 2 It 0 in 1 ft 4 in None 0.7 0.3 N 17.8 ft- 2 It 0 in 1 ft4in None 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None None None GARAGE VFloor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 528 ft2 528 ft2 30 Ift 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 2575.1 141.37 265.86 .2919 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34 kBtuthr I sys#1 COOLING SYSTEM v # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 47 kBtulhr 1410 cfm 0.8 1 sys#1 HOT WATER SYSTEM v# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM v FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft, DUCTS # --- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Atfic 6 200 ft- Attic 20 ft- Default Leakage AHU CLST (Default) c(Default) c 1 1 4/29/2019 11:44 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Prograrnable Thermostat: N Ceiling Fans: Cooling HJan Heating Jan H Feb Feb N Mar Mar Apr Apr I j May may n Jun Jun Jul Jul n A ug Aug S:p S Oct Oct J� ov N IN Dec Dec Venting Jan Feb Mar Apr may Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule -Type- 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Hearing (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Hqating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 011? 0 ft 0.3 OWIC1 Default(8 lbs/sq.ft. ft2 ft 0.3 OWIC2 Default(8 lbs/sq.ft. ft2 ft 0.3 0 BATH Default(8 lbs/sq.ft. fp ft 0.3 LIVING ROOM Default(8 lbs/sq.ft. fp ft 0.3 FOYER Defauft(B lbs/sq.fi. ft 0.3 DINING ROOM Default(8 lbs/sq.ft. ft 0.3 FAMILYROOM Default(B lbs/sq.ft. ft, ft 0.3 BREAKFAST Default(8 lbstsq.ft. W ft 0.3 HALLWAY Default(8 lbs/sq.ft. ftz ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft- ft 0.3 HALL2 Default(8 [bs/sq.ft. 112 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. IF ft 0.3 AHU CLST Default(8 bs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft- ft 0.3 BEDROOM2 Default(8 lbs/sq.ft. 112 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. f? ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft- ft 0.3 CLST 4 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft 0.3 0 TOILET Default(8 lbstsq.ft. ft� ft 0.3 OWNERS BEDRO Name: Rating Compant: Date: 4-29-19 OEM 4/2912019 11:44 AM EnergyGauge@) USA Section R405.4.1 Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1 . New home or, addition 1 . New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-fami y b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity__47.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 2508 d) Room unit/PTAC EER a) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.660 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 34.0 c) Area 7c.271.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA a) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 1 0A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 1 OA2. 4.1 0 Heat recovery unit HeatRecO/ B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10BI. 11.0 2. Masonry (Insulation R-value) 110132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1 la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No a) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signat a4t_t1';tC ?- Date: 14.2q.11 Address of New Home: 8504 WATERSTONE BOULEVARD Cfty1FL Zip: FORT PIERCE, FL 4/29/2019 11:45:06 AM EnergyGauge@ USA 6.0.02 - FIaRes2017 FBC 6th Edition (2017) Compliant Software Page I of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Liudsdiction ST LUCIE COUNTY Permit #: -Job-Information— Builder: ADAMS HOMES Community: Lot: NA Address: 8504 WATERSTONE BOULEVARD City: FORT PIERCE State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, I ERI Method ci� 0 PRESCRIPTivr METHOD ' -The bu idling or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air, changes par hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. 0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verifted as having an air leakage rate of not exceeding the selected ACH(60) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub-section'ACH50. ACH(50) specified on Form R405-2017-Energy Calo (Performance) or R406-2017 (ERO: x 60 22072 Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans 1-1 PASS 0 Code software calculated F-1 When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordancevAth ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (t) or an approved third party. A written report of the results of the test shall be signed bythe party conducting thetest and prmided to thecode official Testing shall be performed at my time after creation of all penetrations of the buOing thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and himit recovery ventilators shall be closed and sealed. 5. Healing and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. [Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 4/2912019 11:45:35 AM EnergyGauge@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of I wrightsoft- Project Summary Job: 2508MODELCR Date: Apr29,2019 Entire House By: QUICK CALICS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fa;c 772466-6796 Emil: QUICKCALCS@AOL.COM Project Information For. ADAMS HOMES 8504 WATERSTONE BOULEVARD, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF D:Ilay M t!angemi R ive dity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25109 Btuh Structure 23089 Btuh Ducts 8723 Btuh Ducts 12441 Btuh Central vent (0 cfm) 0 Stuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Plpipg 0 Btuh Equipment load 33832 Btuh Use manufacturer's data In Ratelswin multiplier 0.95 Infiltration Equipmen?sensible load 33753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4459 Btuh Ducts 3483 Btuh Central vent (0 cfm) 0 Btuh Heatin Area Coolin (none) (ft2) 2509 2 53 Equipment latent load 7942 Btuh Volume (ft3) 22073 22073 Air changes(hour 0.32 0.16 Equipment Total Load (Sen+Lat) 41695 Btuh Equiv. AVF (cfm) 118 59 R6q. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carder Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO4800GOA0 Cond CH14NBO4800GOA0 AHRI ref 9162926 Coll FX4DNF061L AHRI ref 9162926 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 32900 Btuh Heating output 44500 Btuh @ 47'F Latent cooling 14100 Btuh Temperature rise 26 OF Total cooling 47000 Btuh Actual air flow 1667 cfm Actual air flow 1567 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H20 Static pressure 1.00 in H20 Space thermostat Load sensible heat ratio 0.82 Capacity balance point 35 OF Backup: Input = 9 kW, Output 29806 Btuh, 100 AFU E Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -17- Aj- �riglliiios;�rt- 2019-Apr-29 11:32:17 s- Right-SulteCg) Universal 2018 18.0.31 RSU08101 Page 1 WATERSTONE 8504- 2508 CR MODEL GAR RIGHTrup Colo = MJ8 Front Door faces: E wrightsoft, Right-M Worksheet Job: 2508 MODEL CR Entire House Date: Apr2g,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire Home OWIC1 2 3 Exposed wall Room height 212.0 It 8.8 ft 9.0 ft 8.0 It heaticool 4 5 Room dimensions Room area 2508.3 ft2 5.0 X 9.0 It 45.0 ft2 TY Construction number 1.1-value (BluIVftW) Or HTM (Btuh/ft� Area (ft2) ar perimeter (ft) Load (Btuh) Anea (ft2) or perimeter (ft) Load (Btuh) Heat FG-I Gross NIPIS Heat Cool Gross N/PIS Heat Coal 6 13AAo6s--- iglazing, cIr low-e 2gIaaIrg,.cIr_1ow:e -0--143 0.650 0.650 n -'4.00 18.20 2:19 14.99 1 4.99 480 30 1_8 ­432 0 - 1730 546 .450 26_8 0 0 0 ---0 0 ---'o 0 A '0 0 11 13AAocs 2 g1ming, cIr low-e 0.143 0.650 ._n_ a a _18.20 4.00 18.2D - 2.19 3Z42 314 30 _0 228 2 _325 913 5Q 499 973 0 0 __0 0 0 0 0 -0 0 0 2 g1ming, cIr Iow-e -11DO J�KAZ;cs 0.650 0.390 0.143 a -' a s 18.20 1 - 0.92 4.00 32.65 --- 10.34 2.19 36 20 466 2 _20 424 655 219 1698 1175 _208 928 0 0 72 0 0 72 0 0 29B 0 0 168 �`glazing, clr Iow� 2 glazing. cIr low-e 0.650 0.650 s a 18.20 18.20 14.99 14.99 9 15 9 15 164 273 135 225 0 0 0 0 0 0 0 0 2gIazIng.cIrIcw-e- 1aA-400s 2 glazing, cir Icw-e im-4ocs' ---- 2 glazing, cIr low-e O.&M 0.143 0.650 6.143 O.W -a- sw sw -,W- w ---18.20 4.00 18.20 -4.00 18.20 -14.99 2.19 19.57 - 2.19 32.42 18 50 8 - -484 90 42 5 ­376 6 - 325 168 146 -'- -1506 1638 -.--268 92 157 2918 A 0 0 -0 0 ---0 0 0 -- -0 0 0 0 0 0 0 -.0 0 0 -- 0 0 C 2g1azing,,cIrIow-e__ . 16B-30ad -' 22A-tph-:- 0.650 ' 0.032 -1.35B _w 1&2D 0.90 ---'38.02 ... 32.76 1.60 --'--0.00 _18 2508 2508 _1 2508 -,---212 325 2247 -8061 _.5ffi 4013 -- 0 _O 45 _45 __0 45 '---g 0 40 -342 ------ 0 72 -0 6 a) AED excursion 558 -13 Erwelope loss/gain 21486 15218 671 217 12 a) Infiltration 3623 970 145 39 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 6900 0 Subtotal (lines 6 to 13) 25109 23089 816 256 Loss external load 0 0 0 0 14 Less transfer Recristnbution Subtotal 0 0 25109 0 0 23089 0 0 816 0 0 256 15 Duct loads 35%1 54% 8723 12441 35% SVI. 284 138 Total room load Air required (cfnn) 1 331132 1567 355M 1567 1100 51 394 17 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. RigWSuiteO Uniwrsal 2018 18.0.31 RSU08101 2019-Apr-29 11:32:17 I&N ... S-WATERSTONE8504-2508 CR MODEL GAR RIGHTup CsIc=MJ8 FrontDoorfaces: E Page 1 wrightsoft, Right-J@ Worksheet Job: 2508MODELCR Date: Apr29,2019 Entire House By; QUICK CALCS, INC. 317 ST LUC I E LANE, FORT PIERCE. FL 34946 Phone: 772-466-6799 Fac 772-466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name 0 WIC 2 0 BATH 2 Exposed wall 0 It 11.0 It 3 Room height 8.0 It heat/ccol 8.0 It heat/cool 4 5 Room dimensions Room area 5.0 x 9.0 ft 45.0 ft- 1.0 x 119.0 ft 119.0 Iff TY Construction U-value Or HTM Area (112) Lead kea (w) Lead number (BtuWftk'F) pulml or perimeter (ft) (Btuh) or penmeler (ft) (Btuh) He Cool Gross N/PIS Heat Cool Gross NIF/S Heat Cool 6 V6 13A:21ocs 2 Slating, cir Icw-e 2 glazing, cIr low-s, 0.143 0.650 0.650 n' n n -4.00 18.20 18.20 2�19 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 A 0 0 0 0 0 0 0 0 --- 0 0 0 11 13A-4ocs 2 glazing, cir low-e 0.143 0.650 a a 4.00 18.20 2. 19 3Z42 0 0 0 0 0 0 0 0 0 0 b 0 0 -0 0 2 glazing, cIr low-e 11DO 13A-4&�s 0.650 0.390 0.143 a a --a- 18.20 10.92 4.00 32.65 10.34 - 2A9 0 0 -0 0 0 -0 0 0 -0 0 0 0 0 88 0 0 79 0 0 �S,6 0 0 --- 173 v 2 glazing, cir low� 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 9 0 9 0 164 0 135 0 T-G 2glmlng, cirlow-e- 13A41ocs 2 glazing, cIr Iow-e -0.650 0.143 0.650 s sw sw -18.20 4.00 18.20 .14.99 Z19 19.57 _0 0 0 0 0 0 - G 0 0 -0 0 0 -0 0 0 0 0 0 - 0 0 0 .0 0 0 13A-4ocs- - - --- 2 glazing, cIr low-e 0.143 0.650 W- w - '4.6D 18.2) 2�.19 32.42 0 0 0 0 0 0 -0 0 - 0 0 0 0 - 0 0 0 0 C 2 glazing, cir low-e 16B-30ad 0.650 0.032 w --18.20 0.9) 32.76 1.60 . ..... . 0 45 0 45 0 40 �G 72 -0 119 ----0 119 0 107 .0 190 F- 22A:tph 1.358 38.02 '0.00 '45 0 -0 0 119 418 -0 61 0) AED -3 40 Emelope loss/gin 40 69 1OD5 458 12 a) Infiltration 0 0 178 48 b) Room ventilation 0 0 0 0 13 Internal gams: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal (lines 6 to 13) 40 69 1183 806 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 40 69 1183 806 15 Duct loads 1 35%1 541/61 14 37 35% 549/6 411 434 Total mm load 1 54 1 106 1594 1240 Adr required (cfm) 3 5 74 55 Calculations approved by ACCA to meet all Mulrements of Manual J 8th Ed. �rllolft��Vt- 2019.Apr-29 11:32:17 Right -Suite@ Univemal 2018 18.0.31 RSU08101 Page 2 S- WATERSTONE 8504- 2508 CR MODEL GAR RIGHTrup Calc=MJ8 FmntDoorfaces: E wrightsoft, Right-.10 Worksheet Job: 2508 MODEL CR Entire House Date: Apr29,2019 QUICK CALICS, INC. 13y: 317 ST LUCIE LANE, FORT PIERCE, Fl. 34946 Phone: 772466-6799 Fa� 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING ROOM FOYER 2 3 Eqxsed wall Room height 32.0 It 8.0 it heat/cool 8.0 it 10.0 it heat1cool 4 5 Room dimensions Room area 13.0 x 14.0 It 18ZO W 8.0 x 9.0 ft 72.0 ft2 Ty Construction number U-valw (Btula/ft�'F) Or HTM (Btuh/ft2) A- (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) H Ccol Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4oci- 2 gluing, cir low-e 2 glazing, qlrlow� DA43 0.650 0.650 6' n n 4.00 18.20 18.20 2.19 14.99 14.99 40 0 0 40 0 0 ----160 0 0 -88 0 0 0 0 0 -0 0 0 0 0 0 13A-40cs 2 gluing, cIr low -a 0.143 0.650 e e 4.00 18.2D 2.19 32.42 104 30 74 2 546 -162 973 80 0 60 0 M 0 131 0 2 gluing, cIr low-e 1100 13A-4ocs 2 gluing, cIr Iow� 2 g1ming, cir Iow-e 0.65D 0.390 0.143 0.650 0.650 e -e a a a 18.2D 10.92 4.00 18.2D 18.20 3265 . 10.34 2.19 14.99 14.99 0 0 112 0 15 0 0 97 0 15 0 0 -388 0 273 0 0 M 0 225 0 20 - 0 0 0 0 20 0 0 0 0 219 0 0 0 0 208 0 0 0 2 gluing, cIr Iow-e 13A-4ws 2 gluing, cir Iow-e 13A4Rs---- - 2 glazing, cIr Iow� --0.650 0.143 0.650 0143 0.&90 -a sw sw -W w -18.20 4.00 18.20 - 4.00 18.20 14.99 219 19.57 - Z19 32.42 A 0 0 0 0 -0 0 0 0 0 __a 0 0 -0 0 -0 0 0 0 0 0 0 0 0 0 -0 0 0 - 0 0 -0 0 0 0 0 --o 0 0 0 0 G F 2 gluing, cl� jow-e . 16B-30ad 22A-tph (LIM90 0.032 1.358 -w 18.20 0.90 38.02 32.76 1.60 0.00 0 182 182 0 182 32 0 163 1217 0 291 0 0 72 72 0 72 8 -0 65 304 -0 115 0 6 c) AED excursion -99 -24 Emelope lossigain 3044 1851 828 430 12 a) Infiltration 517 138 162 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 01 0 Subtotal (lines 6 to 13) 3561 1990 990 474 Less e)demal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 343 3903 0 164 2154 0 -990 0 0 -474 0 15 Duct loads 35% 54% 1356 1161 0 0 Total nown load Air required (cfm) 1 5259 244 3314 146 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rP- 2019-Apr-29 11-32-17 ------ -.-- Right-Suite(D Uniwrsal 2018 18.0.31 RSUG8101 S- WATERSTONE 8504- 2508 CR MODEL GAR RIGHT.rup Cale = MJ8 Front Door faces: E Page 3 wrightsoft' Right-.10 Worksheet Job: 2508 MODEL CR Entire House Date: Apr2g,2019 QUICK CALCS, INC. By: 317 ST LUC I E LANE. FORT PIERCE, FL 34946 Phone: 772466-6799 Fa�: 772466-6796 Emil: QUICKCALCS@AOL.COM I Room name DINING ROOM FAMILYROOM 2 E>posed wall 14.0 ft 18.0 ft 3 Room height 10.0 It heat/cocl 10.0 it heatlecof 4 5 Room dimensions Room area 13.0 x 13.0 It 169.0 f? 1.0 x 541.5 ft 541.5 ft2 Tl�-- --- Construction Ll-value Or HTM Area (111) Load Area OF) Load number (Btuhlft�F) (BtutVft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat TC---I Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 \613A�40U 2 glazing, cir lcw� 2 glahing, cIr low-e 0.143 0.650 -___0.650 n n n 4.00 18.20 18.20 219 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 --- 0 0 0 0 0 0 i 1 13A-4ocs 2 glazing, cIr low� 0.143 0.650 e e 4.00 18.20 �.ig 32.42 �aI 0 ---94 0 �n 0 -J66 0 0 0 0 0 6 0 6 0 2 giming, cir low-e -11DO 1:M-46-cs- 0.650 -1 ... -0 390 0 143 a a s 18.20 10.92 4,00 32.65 10.34 219 36 0 -10 2 0 10 &1Z 0 -�* 1175 0 22 0 __0 0 0 0 0 0 _-0 0 0 0 0 2 glazing, cIr low-e 2 glazing, cIr lcw� O.M 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 gladng, cIr Icw-e ---0.650 -a --18.2D --14.99 0 0 __0 -.0 -0 A - 0 0 13A-4ocs 2 glazing, cIr low-e 0.143 0.650 sw sw 4.00 18.20 2.19 19.57 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13AA6cs-- -- 2 glazing, cIr lcw� - - -'-0.143 0.650 vi w -4.00 18.20 -219 3242 0 0 0 0 - 0 0 0 0 180 30 132 2 529 546 289 973 C 2glazingl,,clrlow� 1613-30ad 0.650 0.032 vv - 18.20 0.90 3Z76 1.60 0 169 - 0 169 0 151 0 270 18 542 1 542 ---325 485 5B5 866 F 22A-t ph 1.358 - 38.02 0.00 169 '14 532 - 0 542 18 694 �O 6 c) AED excursion 435 Ernelope loss/gain 1755 1617 2570 3148 12 a) Infiltration 2113 76 363 97 b) Room %entilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Apoiances/other 0 2500 Subtotal (lines 6 to 13) 2038 1693 2933 5746 Less odernad load 0 0 0 0 Less transfer 0 0 0 0 Recristribution 343 164 318 169 1 ublotal 2381 1857 3252 5915 15 Duct loads 35% 54% 827 1001 35% 54% 1130 3187 Total room load 3208 2&98 4381 9102 Air required (cfm) 149 126 203 401 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Apr-29 :32:17 RIgWSuite& Universal 2018 18.0.31 RSU08101 Page 4 ... S-WATERSTONE 8504-2508 CR MODEL GAR RIGHTrup Calc=MJB FrontDoorfaces: E wrightsoft Right-M Worksheet J013: 2508 MODEL CIR Entire House Date: Apr29,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name BREAKFAST HALLWAY 2 Eiposed wall 9.0 It 0 It 3 Room height 10.0 ft heat/cocil 8.0 It heatIccol 4 5 Room dimensions Room area 1.0 X 65.0 ft 65.0 ft2 17.0 x 5.0 fit 85.0 ft2 Ty Construction U-Value Or HTM Area (ft2) Load Area (W) Load number (BtulVft�*F) (BtulVW) or perimeter (fit) (Btuh) or penmeter (ft) (Btuh) Heat Cool Gross N/P/S Heat cool Gross N/P/S Heat Coal 6 13A-4o5s- 2 glazing, clir low-e 2 glazing, dF low-e 0143 0.650 0.650 in n. -4.00 18.2D 18.20 '2. . 19 1 4.99 14.99 0 0 0 0 0 0 0 0 0 '0 0 0 -0 0 0 0 0 0 0 0 0 0 it 13A-4ocs 2 glazing, clr low-e 0.143 0.650 a a 4.00 18.20 219 3242 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 2 g1ming, clr Im-e 1100 13A41cZs' 0.650 0.390 0.143 a a s 18.20 10.92 4.00 3265 10.34 2.19 0 _O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cIr Icw-e 2 g1ming, clr low-e 0.650 0.650 a s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cIr low -a 0.650 -s- 18.23 -14.99 __0 0 ____o -0 0 -0- 0 0 T-G 13A-4ocs 2 glazing, cir ow-e 0.143 O.PW sw �S�w 4.00 18.20 2.19 19t57 50 8 42 5 168 146 92 157 0 0 0 0 0 0 0 0 13A-4ocs' - - - - 2 glazing, cir ow-e 0.-143 0.650, �W w -4.00 18.2D - 2 . 19 32.42 40 15 25 1 -100 273 486 0 - 0 0 - 0 0 0 2 glazing, cIr low� 16B-30ad 22A-tph 0.650 0.032 1.358 w m 18.2D 0.90 38.02 32.76 1.60 0.00 _0 65 '65 ---0 65 _ 0 58 342 _-__O 104 0 -0 85 85 0 85 0 -0 76 0 0 136 --0 C: F- 6 c) AED excursion 238 -6 Envelope loss/gam 1 1087 1132 76 130 12 a) Infiltration 182 49 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliarreaslother 400 0 Subtotal (lines 6 to 13) 1269 1581 76 130 Less iodemal load 0 0 0 Less banister 0 0 0 0 Redistribution 16 27 -76 -130 14 Subtotal 1285 1 607 0 0 15 Duct loads 35% 54% 446 866 35% 54% 0 0 Total room load Adr required (cfm) I 1731 80 I 2473 1091 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -rp- 2019-Apr.29 11:32:17 Right-SuiteOUni�mal2Ol8l8.0.31RSU08101 Page 5 ... S-WATERSTONE 8504- 2508 CR MODEL GAR RIGHT.rup Calc=MJ8 FrontDoorfaces: E wrightsoft, Right-J@ Worksheet Job: 2508 MODEL CR Entire House Date: Apr2g,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN HALL 2 2 3 Eq)osed wall Room height 0 ft 10.0 ft heaticoo�l 0 Ift 8.0 It heat/cooll 4 5 Room dimensions Room me 13.0 x 12.0 It 156.0 ft2 13.0 x 4.0 ft 52.0 W TY construction number U-value (Btuh/ft�F) Or HTIVI (BtulVft5 Area (ft!) or perimeter (ft) Load (8tuh) Ares, (ft2) or perimeter (ft) Load (Btuh) Heat Fccol Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 V�'j 13A4ocs- 2 gluing, cir low -a 2 gluing, S;lr low-e laA-4ws 2 gluing, cir low-e 2 gluing, cir low-e 11DO 13A-4&is 0.'143 0.650 0.650 0.143 0.650 0.650 0.390 0.143 'n n n a a a -' e a 4.00 18.20 18.20 4.DO 18.2D 18.2D 10.92 4.00 2.19 14.99 14.99 2.19 32.42 32.65 10.34 2.19 0 0 0 0 0 0 _O 0 0 0 0 -0 0 0 _-O 0 0 0 0 0 0 0 _0, 0 -'-0 0 0 -0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 --0 0 0 0 - 0 -0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 2 gluing, cIr low-e 2 gluing, cir low -a 0.650 0.650 a a 1112D 11120) 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T-a 2 glazin cIr low -a 13A-40cs 2 gluing, cir law-e '13AA(ics- - 2 gluing, cir lowe 0.650 0.143 0.650 - - 0.143 0.650 �s sw sw -%W w -18.20 4.00 18.20 -4.00 18.20 14,99 2.19 19.57 2:19 3Z42 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 -0 0 0 - 0 0 0 0 0 -0 0 0 0 0 0 0 c F- --- 2 gluing, clrlowwe 16B-30ad 22A-tph- - 0.650 0.032 1.358 w 18.20 0.9) 38.02 32.76 1.60 0.00 0 156 156 0 156 0 -0 140 0 250 0 --.-o 52 52 -0 52 --G .0 47 0 - - - 83 0 6 c)AED excursion -69 4 E�elolpe losstgain 140 181 47 79 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 1200 0 Subtotal (lines 6 to 13) 140 1381 47 79 Leas e)demal load 0 0 0 1 Less transfer Reclistribution Subtotal 0 45 185 0 76 1457 151 Duct loa 35%1 54%1 64 785 35% 54% Tctal =in load Air required (cfm) 1 1 249 12 2243 99 Calculations waroved bvACCA to meet all reouirements of Manual J 8th Ed Right-Sulteg) Uniwisal 2018 18.D.31 RSUD8101 2019-Apr.29 11:32:17 S- WATERSTONE 8504-2508 CR MODEL GAR RIGITErup Calc=MJ8 FrontDoorfaces: E Page 6 wrightsoft Right-J@ Worksheet Job: 2508MODELCR Entire House Date: Apr29,20ig QUICK CALICS, INC. By: 317 ST LUCIE LANE, FORT PIERCE. FIL 34946 Phone: 772466-6799 Fax 772�66-6796 Email: QUICKCALCS@AOL.COM I Rcam name LAUNDRY AHU CLST 2 5posed wall 0 If 0 it 3 Room height 8.0 ft heat/cool 8.0 It heat/ccol 4 5 Room dimensions Room area 1.0 x 73.0 it 73.0 it- 3.0 x 5.0 it 15.0 1? Ty Constnuction U-valw Or HTM Area (ft2) Load Area (112) Load number (BtulVft�*F) (Btutvft2) or perimeter (ft) (Btuh) or perimeter (ft) (13tuh) Heat C-1 Gross N/PIS Hmt Cool Gross NIP/S Heat Ccol 6 13A-4ccs- 2 glazing. cir Icw-e 2 g!azing, chrlm-e 0. 143 0.650 0.650 n n n- 4.00 18.20 18.20 2.19 14.99 14.99 0 0 0 0 0 0 ---G a 0 0 0 0 0 0 0 0 0 0 0 0 0 11 13A-4ocs 2 glazing, cIr Icw-e 0.143 0.650 a a 4.00 18.20 2.19 3Z42 0 0 0 0 0 0 -0 0 0 -0 0 0 0 0 a 0 �0 0 0 2 glazing, cIr Icw-a 11D0 13A46cs 0.650 0.390 -0.143 a a s� 18.20 10.92 - 4.01) 3Z65 10.34 -2.19 0 0 0 0 .0 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 0 0 0 '0 2 glazing, cIr Im-e 2 glazing, cIr Iow-e 0.650 0.650 a s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T-a 2 glazing, cir Iow-e 13A-4acs 2 glazing, cir low-e - -- 2 glazing, cir Iow-e 0.650 0.143 0.650 GL.143 0.650 a sw sw w w 18.20 4.00 11121) 4.00 11120 14.99 219 19.57 2.19- 32.42 -0 0 0 ---'0 0 0 0 0 -0- 0 ...0 0 0 0 0 0 0 0 --- 0 0 0 0 0 0 0 0 0 -0 0 0 - -0 0 -0 0 0 0 0 ---,o 0 "L13AAocs 21 C 2 glazing, c1r Icw�e 16B-30ad 0.650 0.032 w 18.20 0.91) 32.76 1.60 -- 0 73 0 73 -0 65 - 0 117 ----- - - 0 15 -0 15 . . . 0 13 __0 24 F 22A4ph .358 31102 .0.00 73 0 0 -0 15 0 0 ---a 6 c) AED mursion -29 -1 Envelope lossIgain 65 88 131 23 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 App(lariceslother 500 0 Subtotal Qinw 6 to 13) 65 M 13 23 Less wdennal load 0 0 0 0 Less mansfer 0 0 0 Redistribution 16 27 -13 -23 14 ubtotal 81 614 0 1 1 5 Duct loads 1 35%1 54%1 28 331 35% 549/61 0 01 0 Total morn load 109 1 946 0 - 0 Air required (dm) 5 42 01 10 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -F$- 2019-Apr-29 IT �2V lap, Rlght�Sulte@) Uni�rsal 2018 18.0.31 RSU08101 Page 7 ... S- WATERSTONE 8504- 2508 CR MODEL GAR RIGIiTruP Cale = MJ8 Front Door faces: E wrightsoft, Right-M) Worksheet Job: 2508MODELCR Entire House Date: Apr29,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Emil: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2 0 If 8.0 ft heat/cool 5.0 X 9.0 If 45.0 ft2 CLST 2 2-0 ft 8.0 It heaticool 11.0 x 2.0 ft 22.0 W -fy Construction number U-value (BtuIVW-'F) 0, HTM (Btuhlft� A. (ft2) or perimeter (ft) Lead (Btuh) Anse, (ft2) or pollinator (it) Lead (Btuh) Heaft Coal Gross N/PIS Host Coul G ross WRIS Heat Cool 6 13A-��s 2 glazing, clir Icw� 2 glazingfc1�1my-q ....... 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 11DO 1 -s-- 3A-4oc 2 glazing, cIr Im-e 2 glazing, cIr low-e 2 glazing, clir.lomr-e 2 giming, cIr low� IZA40cs� 2 glazing, cIr Icw-e 2 glming,,cir lcw�e 16B-30ad 2?A:tph-7-----' -- O.W 0.650 Q.650 0.u� 0.650 0.650 0.390 0.650 0.650 0.650 0.143 0.650 0.143 0.650 _,0.650 0.032 1.3513 -- -- ---- -fi n n - - a a a a a s -s.- sw sw --v� w _%v - - - 4,00 18.20 - 18.20 18.2) 18.20 10.92 4.00 18.2D 18.2D --18.20 4.00 18.2D -47.00 18.20 _J8.20 0.90 '38.02 .19 -:r 14.99 14.99 32.42 32.65 ---10.34 2.19 14.99 14.99 --:14.99 2.19 19.57 "2-19 32.42 32.76 1.60 '0 00 -0 0 ___O 0 0 0 0 0 0 0 0 0 0 -'---o 0 __0 45 -45 0 0 0 -0 0 0 0 0 0 0 --0 0 0 ---0 0 _,_,__O 45 0 0 0 0 -0 0 0 0 0 0 0 0 0 -0 0 40 ------- 0 0 0 0 0 0 0, 0 0 0 --0 0 0 0 72 -0 - ----- -- 16 0 -0 0 0 0 0 0 0 --0 0 0 ------o 0 �-.I) 22 --22 16 0 0 '0 0 0 0 0 0 0 ----- - 0 0 0 0 0 -0 22 -- 2 --64 0 _�__p 0 0 0 0 0 0 0 '--,--0 0 0 0 �0 ---'-jD 20 --76 35 0 _ 0 0 0 0 0 0 0 0 _0 0 - 0 0 0 --,----0 35 __0 VE_G13AAocs C F- 6 c) AEC) excursion -13 -4 Envelope loss/gain 40 59 160 66 12 a) Infiltration 0 0 32 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 200 0 Subtotal Oines 6 to 13) 40 259 192 75 14 1151 Less external load Less transfer Redistribution Subtotal Duct loads 35% 54% 0 0 13 53 18 0 0 22 281 151 35% 540/6 0 0 -192 0 0 0 0 -75 0 0 T at room load .'trequired (cfm) 71 3 432 19 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 2019-Apr-29 11:32:17 ACCK Right-Suitea, Uniwi-sal 2018 18.0.31 RSU08101 Page 8 S- WATERSTONE 8504- 2508 CR MODEL GAR RIGHTrup Calc = MJ8 Front Door faces: E wrightsoft' Right-M Worksheet Job: 2508MODELCR Entire House Date: Apr29,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email; QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 BEDROOM3 2 EVosed wall 13.0 ft 12.0 ft 3 Room height 8.0 It heat/cool 8.0 It heatfcool 4 5 Room dimensions Room area 11.0 x 13.0 It 143.0 W 11.0 x 12.0 ft 132.0 1? TY Construction U-value Or HTM Area (ft2) Lead Area Lead number (Btuh/ftk*F) (BtuiVftl at perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat FC-I Gross N/P/S Heat Coal Ems N/P/S Heat Coal 6 l3A-4o6S-- 2 glazing, cir low� 2 glazing, cIr ow-e 0.143 0.650 0.650 6 n n --4.06 18.20 18.20 '2:19 14.99 14.99, 104 15 0 - ------ 89 0 0 ---'356 273 0 195 225 0 ­96 15 0 ----81 0 0 ­ --3f4 273 0 177 225 0 13A:42cs 2 glazing, cIr ow-e --0. 1-43 0.650 e- a --A.0-0 18.20 --2.-19 32.42 -6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cIr low-e .11DO 13A-46�j­ -- -- - O�650 0.390 -- -0.143 a a -s- 18.20 _ _10.92 -4.00 32.65 _10.34 2.19 0 0 -0 0 0 0 0 0 0 -0 0 _'_0 0 0 __'_0 0 0 Q 0 0 ---- 0 0 2 glazing, cir low-e 2 glazing, ch- low-e 0.650 0.650 a a 18.2D 18.20 14.99 14.99 0 0 0 0 0 0 0' 0 0 0 0 , 0 0 0 0 0 2glazing,.cIrlow-e- 0.650 -a. -18.20 -14.99 -.---0 -,,---0 -0 --0 -0 -0 . -0 0 t-G 13A-4ocs 2 glazing, cir low-e 0.143 0.650 sw sw 4.00 18.20 2.19 19.57 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A�s- - - - - - 2 g1ming, cir low-e --Cf.143 0.650 -%W w 7�17. 00 18.20 _Y19 3242 ­ 0 0 -0 0 --'--o 0 7 -0 0 -b 0 0 --0 0 '0 0 C F:--- - - - 2 glazing, cIr low�e__ 16B-30ad 22A-tph--. - - - - -- - 0.650 0.032 - .358 1 _w_ 18.20 0.90 -38.02 _32.76 1.60 - 0.00 _0 143 - - - - - 0 M '13 - - ---- - ---- --- 0 128 �-4941 -- _-_-O 229 ___0 132 132----' - - - - - - - -_- 0 132 12 ----,0 118 -4515 -0 211 -----,0 6 c) AEC excursion -71 -69 Enwlope loss/gain 1252 5T7 1172 544 12 a) Infiltration 210 56 194 52 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 ApAances/other 800 800 Subtotal (Imes 6 to 13) 1462 1433 1366 1396 Less odennal lead 0 0; 0 0 Less trarzfer 0 0 0 0 Redistnbution 198 85 285 108 14 Subtotal 1660 1519 1651 1503 15 Duct loads 35%1 54% 5-n 818 31.5%. 54% 574 810 Total morn load 1 M7 M7 2225 2314 Air required (Gfm) 104 103 103 102 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -rw �� 2019-Apr-29 11:32:17 Right -Suite@ Uniwmal 2018 1&0.31 RSU08101 Page 9 S- WATERSTONE 8504- 2508 CR MODEL GAR RIGHT.nup Cale = MJ8 Front Door feces: E wrightsoft, Right-M Worksheet Job: 2508MODELCR Date: Apr29,2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone; 772466-6799 Fzoc 772466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name CLST 3 CLST 4 2 Bq�osed wall 3.0 ft 2.0 It 3 Room height 8.0 ft heat/cool 8.0 ft heat/ccol 4 5 Room dimensions Room area 7.1 x &0 ft 21.3 W 7.0 x 2.0 ft 14.0 W TY Construction U-value Or HTM Area M Lead Area (ft') Load number (BtuIVftMF) (BtutVft') or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat C-1 Gross N/P/S Heat CMI Gross NIP/S Heat Cool 6 T� QAA�S7--' 2 glazing, cIr lom-e 2 gLoAng,cir low-e 0.'143 0.&50 0.65D n In 18.20 18.21) '2.19 14.99 14.99 '24 0 0 "---'-24 0 96 0 53 0 0 16--- 0 0 0 a -64 0 35 0 0 11 13A-4ms 2 g1ming, cIr low-e 0.143 0.650 e a 4.00 18.20 219 3242 0 0 __.___o -0 0 -0 0 0 0 0 0 0 0 __0 'S 0 0 0 2 g1ming, cIr lcw� 11DO i'ALd�S­­ --- 0.650 0.390 ---- 0.143 a a -S- 18.2D 10.92 --4.00 3265 __10.34 2.19 0 0 --0 0 0 0 0 ------o 0 0 -'--0 0 0 --"--o a 0 ------o 0 -0 0 0 --o 0 "----o �gladng, cIr Im-e 2 g1ming, cIr low-c 0.650 0,650 a s 18.21) 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Y-a VL13A�-,Iocs 2gIa;Jng,cIrIcw-e--- 13A-4ocs 2 glazing, cIr low-e 2 g1ming, cIr Icw� ----0.650 0.143 0.650 0.143 0.650 -s.. sw sw -W- w -18.2) 4.01) 18.21) '74.00 18.2) - -14.99 219 19.57 -- -Z19 32.42 -0 0 0 -0 0 ---- -0 0 0 0 0 -0 0 0 0 0 -0 0 0 -0 0 --0 0 0 --0 0 -- -0 0 0 --0 0 ----0 0 0 0 0 0 0 0 0 C F 2 glazing, clrlcw� 16B,30ad 22Atph .0.650 0.032 1.358 -W_ 18.20 0.90 38.02 _32 76 1.60 .--0.00 0 21 _21 --- - - - 0 21 ---.,-3 -- ---- 0 19 114 .... . ... �O 34 0. ---- - -- 0 14 ----,14 _0 14 ----- -- _0 13 "76 -------- ---0 22 "-,o 6 c)AED excursion -5 -3 Ernelope lcsslgaln 229 81 153 54 12 a) Infiltration 48 13 32 9 b) Room wnfilabon 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 277 94 185 63 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Rechstribution -277 -94 -185 -63 1 ubtatal 0 0 0 0 15 1 Duct loads 359/6 54% 0 0 35% 54% 0 0 Total room load -7 0 0 0 0 Ak required (cfm) 0 0 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. ='Isil 20119�Apr-29 11:32:17 Right-Suite&Uni�emal2Ol8l8.0.31RSU08101 Page 10 ... S-WATERSTONE 8504-2508 CR MODEL GAR RIGHT.rup Calc=MJ8 FrontOoorfaces:E wrightsoft, Right-JO Worksheet Job: 2508MODIELCR, Entire House Date: Apr29,2019 QUICK CALICS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QU:CKCALCS@AOL.COM 1 Room name BEDROOM 4 BATH 3 2 3 Expcsed wall Room height 24.0 It 8.0 ft heatfcool 14.0 it 8.0 it heat/cool 4 5 Room dimensions Room anea 11.0 x 13.0 It 143.0 it' 1.0 x 97.5 It 97�5 ft2 Ty Construction number U-value (BtulVWF) Or HTM (BtulVftxl Area W) or perimeter (it) Load (Bluh) Area (it') or perimeter (ft) Lead (Btuh) Heat T -CWI -Gross N/F/S Heat Cool Gross NIFIS Heat Cool 6 U 13A466F'-- 2 gluing, Or lw� 2 ghazling, or low-e-_ 13A4ocs 2 glazing, clr low-e 2 gluing, cIr low-e 11DO 13A4Fcs 0.143 0.650 -,_--0.650 0.143 0.650 0.650 .0.390 0. 143 6- n _ n a a e -a s -' -4.00 18.2) _18.20 4.00 18.20 18.20 _-_10.92 4.00 - - f19 14.99 _14.99 2.19 32.42 32.65 _10.34 2.19 104 0 0 0 0 0 0 104 0 _0 0 0 0 0 0 ­416 0 0 0 0 0 0 0 ---- 228 0 ------0 0 0 0 0 0 -­-0 0 0 0 0 0 0 - ----- 40 ­ -- - 0 0 0 0 0 0 0 -22 '--0 0 0 0 0 0 0 89 - ' 0 0 0 0 0 0 0 48 2 gluing, cIr low-e 2 gluing, cIr low-e 0.650 0.650 a a 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T:: C F 2 gluing. cIrlow-e- 13A-4ocs 2 gluing, cir Im-e 13A;46ci---- --- 2 gluing, cir Im-e 2g1azing,c1rlWe--, 1613-30ad 22A-tph 0.650 0.143 0.650 V-1143 0.650 0.650 0.032 .35B --s- sw sw -W w vw�- .. -18.20 4.00 18.20 -4.00 18.2D _18.29 0.90 -38.02 ----14.99 2.19 19.57 - -2:19 3242 _32.76 1.60 0.00 0 0 0 ----88 15 -.--,0 143 -143 -0 0 0 .... 73 1 . . .... �O 143 24 -0 0 0 -292 273 _ 0 128 .----913 - _0 0 0 ---160 486 229 --18 0 0 72 0 98 --- ---- 98---- --18 0 0 72 0 0 98 1 -325 0 0 -288 0 _0 87 .--532 ----.268 0 0 ---158 0 0 156 0 6 c) AED enoursion 159 -33 Enwlope loss/gain 2022 1261 1322 597 12 a) infiltration 338 104 226 61 b) Room ventilation 0 0 0 0 131 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 2410 1365 1548 658 14 15 Less external lead Less thansfer Redistribution Subtotal Duct loads 35%. 54% 0 0 193 2603 904 Oi 0 76� 1442 777 35% 54./. 0 0 12 1560 542 0 0 20 678 3651 Total =in load Air required (cfm) 3507 162 2218 98 2101 97 1D43 46 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed 2019-Apr-29 11:32:17 Right-Suileg) Uriwnsal 2018 18.0.31 RSU08101 Page 11 ... S-WATERSTONE8504-2508 CR MODEL GAR RlGh-rrup Calc=MJ8 FrontDoorfaces: E 0 z YE; L) !Wto 2 0 0 5 C% xv ---- ----- IlM 0 a z IR 0 ------- —Q 33.10 0.9 t5 F FT PRE S, Z VE E is EISO so v;b— ...... so L awl wrightsofto Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM Project Information For. ADAMS HOMES 8504 WATERSTONE BOULEVARD, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H20 0 in H20 1.00 in H20 0.500 / 0.500 in H20 1.000 in/1 0011 1567 cfm 215 Job: 2508MODELCR Date: Apr29,2019 By: Cooling 1.00 in H20 0 in H20 1.00 in H20 0.500 / 0.500 in H20 1.000 Intl 00ft 1567 cfm I Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Cig (cfm) Design FR Diann (in) HxW (in) Duct Matt Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk BATH 2 C 432 3 19 1.000 5.0 OX0 VIFx 6.5 115.0 st2 BATH 3 h 2101 97 46 1.000 6.0 OX0 VIFx 29.1 135.0 st4 BEDROOM 2 h 2237 104 103 1.000 7.0 OX0 VIFx 10.5 115.0 st2 BEDROOM 3 h 2225 103 102 1.000 7.0 OX0 VIFx 15.1 115.0 sti BEDROOM 4 h 3507 162 98 1.000 7.0 OX0 VIFx 30.3 135.0 st4 BREAKFAST C 2473 80 109 1.000 7.0 OX0 VIFx 32.1 135.0 st4 DINING ROOM h 3208 149 126 1.000 7.0 OX0 VIFx 10.1 115.0 st2 FAMILY ROOM C 3034 68 134 1.000 7.0 OX0 VIFx 42.3 135.0 st5 FAMILY ROOM -A C 3034 68 134 1.000 7.0 0XI) VIFx 58.8 155.0 St6 FAMILY ROOM-B C 3034 68 134 1.000 7.0 OX0 VIFx 29.8 115.0 st3 KITCHEN C 2243 12 99 1.000 7.0 OX0 VIFx 14.1 115.0 sti LAUNDRY C 946 5 42 1.000 6.0 OX0 V]Fx 8.0 115.0 st2 LIVING ROOM In 5259 244 146 1.000 8.0 OX0 VIFx 34.6 115.0 st3 • BATH h 1594 74 55 1.000 6.0 OX0 VIFx 43.2 135.0 st5 • TOILET C 56 1 2 1.000 4.0 OX0 VIFx 30.2 115.0 st3 OWIC 1 h 1100 61 17 1.000 4.0 OX0 VIFx 45.8 135.0 St5 0 WIC 2 C 106 3 5 1.000 4.0 OX0 VIFx 41.8 135.0 St5 OWNERS BEDROOM h 2988 138 98 1.000 7.0 OX0 VIFx 60.3 155.0 st6 OWNERS BEDROOM -A h 2988 1 138 1 98 1.000 1 7.0 1 OX0 VIFx 55.4 155.0 st6 ,�, * wrightsaft- 2019-Apr.29 11:32:19 19M S- Right-SufteQD UniWisal 2018 18.0.31 RSU08101 Page 1 ... WATERSTONE 8504-2508 CR MODEL GAR RIGHTnip Calc=MJ8 FrentDoorfaces: E Supply Trunk Detail Table Name Trunk Type Htg (cfm) Cig (cfm) Design FIR Veloc (fpm) Diam (in) HxW (in) Duct Material Trunk st6 Peak AVF 344 330 1.000 632 10.0 0 x 0 VinIFIx st5 st5 Peak AVF 539 541 1.000 689 12.0 0 x 0 VinIFIx st3 st3 PeakAVF 852 823 1.000 694 15.0 0 x 0 VinIFIx st4 — -PeakAVF 340 253 1.000 770 9.0 0 x 0 VinIFIx sit SH Peak AVF 455 454 1.000 689 11.0 0 x 0 VinIFIx st2 Peak AVF 261 290 1.000 656 9.0 0 x 0 VinIFIx I Return Branch Detail Table Name Gd1le Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FR WOO (fpm) Diam (in) HxW (in) Stud/Joist Opening (in) Duct Mati Trunk rbl OX0 1567 1567 0 0 0 0 Ox 0 VIFx -t� -F�- wrightsaft- 2019-Apr-29 11:32:19 AM5 s- Rlqht�Suite@ Uniwrsal 2018 18.0.31 RSUD8101 Page 2 ... WATERSTONE 8504- 2508 OR MODEL GAR RIGHT.rup Calc = MJ8 Front Door faces: E This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.