Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUIL TION Florida Department of Business and Professional Regulation - Resi od Project Name: AITKENS RESIDENCE- 2ND FLOOR ADDITION BullderName:. Street., 15354 NAVION DRIVE Permit Office: ST LUCIE COUNTY SCANNED )hv City, State, Zip: PORT ST LUCIE, FL, BY Pennit Number. Owner. LARRY AJTKENS St Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce Lucie CountVouny- St. Lucie (Florida Climate Zone 2) 1. New construction or wdsting Addition 9. Well Types (1200.0 sqft.) Insulation Anea 2. Single family or multiple family single-family a. Frame - Steel, E)fterior R=11.0 1200.00 1`12 b. N/A R= ft2 3. Number of units, if multiple farnily I c. NIA R= ft2 4. Number of Bedrooms (Bedmins In Addition) 0(0) d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (448.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 448.00 ft- 6. Conditioned floor area above grade 448 b. NIA R= fl? Conditioned floor area below grade (fl:2) 0 c. NIA R= 112 11. Ducts R 1`12 7. Windows(O.0 sqfL) Description Area a. Sup: Attic, Ret Attic, AH: Attic 6 100 a. U-Factor. NlA fI2 SHGC: b. U-Factor. NIA ITZ 12. Cooling systems kBtuthr Efficiency SHGC: a. Central Unit 24.0 SEER:18.00 c. U-Factor. N/A f12 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A 1`12 a Elechic Strip Heat 17.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 0.000 it Area Weighted Average SHGC: 0.000 14. Hot water systems - None required a. Cap: NIA 8. FloorTypes (448.0 sqft.) Insulation Area EF: 0.000 a. Raised Floor R=19.0 448.00 ftZ b. Conservation features b. NIA R= ft2 None c. NIA R= ft, 15. Credits None GlasslFloor Area: 0.000 Total Proposed Modified Loads: 19.67 PAQS Total Baseline Loads: 20.15 I hereby certify that the plans and specifications covered by Review of the plans and S this calculation are In compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy CGde. PREPARED BY: Before construction is completed DATE: 4 -19 this building Vill be inspected for compliance with Section 553.908 I hereby certify th t thi b "Id' designed, is in compliance a U' �0" aa- Florida Statutes. with the Florida EneZCo . e I 0 OWNERIAGEN * jft'4� BUILDING OFFICIAL: DATE: / 19�1-2ra I DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.11.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested In accordance with ANSIIRESNETIICC 380, Is not greater than 0.030 On for whole house. r-ILE COPY 4/2512019 10:36 AM EnergyGaugeg USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT T111w. AITKENS RESIDENCE- 2ND Bedrooms: 0 Address Type: Steel Address Building Type: User Conditioned Area: 448 Lot # Owner Name LARRY AITKENS Total Stories: I BlockiSubdMsion: # of Units: 1 Worst Gasff. No PlatBook'. Builder Namv. Rotate Angle., 0 Street: 15354 NAVION DRIVE Permit Office: ST LUCIE COUNTY Gross Ventilation: No County. St. Lucia Jurisdiction: ST LUCIE COUNTY WhoteHouseFan: No City. State, Zip: PORT ST LUCIE, Family Typff. Single-farry FL, New/E)dsting: Addition Comment: CLIMATE v Design Temp Int Design Temp Healing Design DailyTemp Design Location TMY Site 97.5% 2-5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 76 299 62 Law BLOCKS Number Name Area Volume I Entire House 448 4480 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 OFFICE 256 2560 No 0 1 Yes Yes Yes 2 WIC 54 540 No 0 1 Yes Yes Yes 3 STAIRS 72 720 No 0 1 Yes Yes Yes 4 BATH 66 660 No 0 1 Yes Yes Yes FLOORS v# Floor Type Spam Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor OFFICE — 256 fF 19 1 0 0 2 Raised Floor WIC — 54 fF 19 1 0 0 3 Raised Floor STAIRS — 72 If 19 1 0 0 4 Raised Floor BATH — 66 ft' 19 1 0 0 ROOF Roof Gable Roof Solar SA ErnIft Ernitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 462 IF 66 Q2 Light 0.2 No 0.9 No 0 14 ATTIC V/ Area RBS IRCC # Type Ventilation Vent Relic (1 in) 1 Full affic Vented 150 448 ft2 N N 4125/2019 10:36 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 4 0 IL ui to w U) I-- m IL z C� U) 0 0 0 a 0 0 a a 0 0 0 C4 N N N N N g '4 C4 CR ul LL, Mu Uq z Si w (a 0) U) U) ME W < 0 0 0 (0 z co U) z t5 t5 t b IL F- E B fn F- E 2 M z LU U) w co z w z LU 46 Z 6 L) ui V) 9 D w ,n 0 M LU x IL z CD C� 0 LL IrIall, 0 n N I op w ow W� ww mm QW zzz CY d w 0 L) C/) E < 000 0 L) sp sle 88 88 OXQ fm f2p 28 8 L) Ci Ci Ci ww �� m �sw mm ww E ww ww wo QW m im OWE -0-0 IL w ?2W ww �m WE w Pw om w wa wa Pw ww WE ow ME > 0 1 c z IL IL a- IL SEE 0 2 w a A ox c 0) 's m ra 0 E 0 L) E m z w cc m 0 I co :3 w In 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-fami y b) Return ducts R 6.0 c) AHU location Aftic/Atfic 3. No. of units (if multipleofamily) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity___14.0 a) Split system SEER 18.0 5. Is this a worst case? (yestno) 5. No b) Single package SEER c) Ground/Water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 448 d) Room unit[PTAC EER a) Other 7. Windows, type and area a) U-factor(weighted average) 7a. 0.000 b) Solar Heat Gain Coefficient (SHGQ 7b. -1.000 c) Area 7c.- 0.0 8. Skylights a) LI-factor(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (insulation R-value) 2. Masonry (insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 9b. 19.0 9c. IOAl. 11.0 1OA2. 14. Heating system: Capacity_L7.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system With tank EF a) Dedicated heat pump with tank EF f) Heat recovery unit HeatRedD/o 9) Other 10131. 1OB2. 16. WAC credits claimed (Performance Method) a) Ceiling fans Ila. 19.0 b) Cross ventilation No Ilb. c) Whole house fan No 11c. d) Multizone cooling credit lld. No a) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 15354 NAVION DRIVE - City/FLZip: PORTSTLUCIE.Fl- 4r25/2019 10:36:43 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402A1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: AITKENS RESIDENCE- 2ND FLOOR ADDITION Builder Name., Street: 15354 NAVION DRIVE Perml STLUCIECOUNTY City. State, Zip: PORT ST LUCIE, FL, Pernift Number. Owner. LARRY AJTKENS Jurisdiction: ST LUCIE COUNTY Lu X Design Location: FL, Fort Pierce COMPONENT AIR BARPJER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelopel Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks orjoints in the air barrier shall be sealed. Ceiling/al The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in arty dropped celikWsuffit insulation and any gaps In the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filing the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorlambs; and framing, and and doors skylights and framing shall be sealed. Rimjoists Rim joists shag include the air barrier. Rim joists shag be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shag be Installed to (including madritain permanent contact with the underside of above -garage subfiDor decking, or floor framing cavity insull shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation Installed on the underside of floor frarring and extends from the bottal I to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit. or narrow cavilles shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided betvveen the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air Ught and IC rated. Plumbing and wiring Bait insulation shall be cut neatly to fit around wiring ar J plumbing in exterior walls, or Insulation that an Installation readily conforms to available space shall extend behind piping and wiring. Showeritub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. Insulated. Electricalifiptione, box an The air barrier shall be installed behind electrical or commurficauan exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shad] be sealed to the sub -floor or drywall. Concealed When required to be sealed. concealed fire sprinklers shall only be sealed I sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Males and walls a celings. a. In addition, inspection of log walls shall be in accordancewith the provisions of IGG-400. 412512019 10:36 AM EnergyGaul USA FBC 6th Edition (2017) Compliant Sollware Page 1 of 1 wrightsoft- Project Summary Job: Date; Apr25,2019 Endre House By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE FL 34946 Phonw. 772466-6799 Fax 772466,6796 Effiall: QUICKCALCS@AOLCOM --- -- Project Information For AITKENS RESIDENCE- 2ND FLOOR ADDITION 15354 NAVION DRIVE, PORT ST LUCIE, FL Notes: Design Information Weather. Fort Pierce, Fl, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr1lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 7117 Btuh Structure 15306 Btuh Ducts 1886 Btuh Ducts 2789 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfrn) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Plpipg 0 Btuh Equipment load 9003 Btuh Use manufacturer's data n Ratelswil multiplier 0.95 Infiltration Equipmewsensible load 17190 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2998 Btuh Ducts 723 Btuh Central vent (0 cfm) 0 Btuh Heafi!4g Cool Z� (none) Area (W) Equipment latent load 3721 Btuh Volume (" 4480 4480 Air changeafhour 0.61 0.32 Equipment Total Load (Sen+Lat) 20912 Btuh Equiv. AVF (cfm) 46 24 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTX8024A1000ABA AHRI ref Coll TAM9A0B30V31 AHRI ref Efficiency IGO EFF Efficiency 13.3 EER, 18 SEER Heating input 2.3 kW Sensible cooling 16800 Btuh Heating output 7864 Btuh Latent cooling 7200 Btuh Temperature rise 9 OF Total cooling 24000 Btuh Actual air flow 800 dm Actual air flow 800 Cfm Air flow factor 0.089 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H20 Static pressure 1.00 in H20 Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _PW �rlsllf - - 2019-Apr-25 10:36:00 Right-SullegUih�a]201818.0.31RSL)08101 Page I ... netsWrightsaft WACWTKENS HANGER 2ND FUR.,up Cale - MJB Building Front faces: S 4�- wrightsaft Right -AD Worksheet Job: Date: Apr25,2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE L41,E. FORT PIERCE FL34946 Phone: 772-46M799 F=772-466W96 Emag;QUCKCALCS@AOL.COM 1 Roorn name Entire House OFFICE 2 EVOsed wall 120.0 It 43.0 It 3 Room height 10.0 It 10.0 It heal/cool 4 Roonn dmenslons 1.0 x 258.0 ft 5 Roomarea, 448.0 Ift? 258.0 ft2 TY Construction U-Xdue Or Anse (" Load Am (ft-) Load number qItuWWF) or penmEter (ft) (B") or Perimeter (11) (B") Gross NIFIS Heat Cool Gross NIPIS Heat cool a w 12B-Osm - 0.122 -n 3.42 Z94 ISO ISO M7 470 0 0 0 0 w 1213-Osm 0.122 a 3-42 Z94 440 432 1476 1270 150 ISO 512 441 L—G 2 glazing, cIr lo�e 0.650 a 18.20 33.77 a 0 M 270 0 0 0 0 w 12B-Oam. 0.122 a &42 2.94 160 160 547 470 76 70 239 2D6 I I w 12B-Osm 0.122 w 3.42 Z94 440 440 1503 1294 210 210 717 617 C -168-11md O.OB1 - 2-V 4.05 448 448 1016, 1814 256 255 sBi 1037 F 19A-19bstp 0.049 - 1.08 0.58 w 448 482 258 256 258 275 147 81 )AED ..1. 16 01 Emeloloe lossfgaan 5715 5862 2325 2449 12 a) Wiftn3flM 1402 394 502 141 b) Room veftlabon 0 0 0 0 13 Kemal gains: Occupants @ 230 0 a a 0 Appliancestather 9050 2))] Subtabal (linen, 6 to 13) 7117 imm 2W 1990 Less ademal lost! a 0 0 0 Less transfer 0 0 0 ReclIstributm 0 0 0 0 14 Subtatel 7117 15306 ZB27 4590 15 Duct loads M 18% 1886 2789 27% 18% 749 S360 Total room loW WOO 18ON 35M Air re*rW (cfm) SOO 800 318 __!2�4O Calculations appiroved by ACCA to meet all requirements of Manual J Bth Ed. -Fw 2019-Apr-25 10.,35:00 A&K RTght-SuiteQ I.Inhersall 201818.0.31 RSUO8101 Page I ... nelsWrightsoft WACWTKENS RANGER Z413 FUR.wP Cate - IVIJB Building Front faces: S wrightsoft Right-M Worksheet Job: Date: Apr26,2019 Endre House By: QUICK CALCS, INC. 317 ST WClE LAN=, FORT PIERCF FL 34946 Phone: T72-466-6799 Few 772-466-3796 Ernall: OtACKCALCS@AOLCOM 1 Roonnnanne, wic BOSTING 2 EVMW Wall 21.0 ft 39.0 ft 3 Roxn height 10.0 ft heal/cod 10.0 It heaticod 4 5 Roonn climensloca Roxn area 6.0 x 9.0 ft 54.0 it- 1.0 x 7ZO It 72 0 fL- TY Construction U-value Or HTM Area (fe) LOW Anea (ft-) Load mmb� (Etuh/WF) (Bwft2) w perimeter (ft) (Btuh) w pentreter (ft) (Btuh) H;i�cod Gnoss WRIS Heat cool Gam NIPIS Heat cool 6 w w 12B-03m 12B-Osm OA22 0.122 n a 3.42 3.42 2B4 294 0 60 a so 0 2D5 0 176 50 170 so 170 171 Sal 147 5m L—G 2 glazing, clr lo�e 0.650 0 10,2D 33.7 7 0 a 0 0 a a 0 0 w 12B-Osm 0.122 a &42 - 2.94 go 90 -3(17 285 a 0 _0 0 11 w 12B Osm 0.122 w 3.42 2-94 60 60 2D5 176 170 170 5al 500 C 1613-11rral 0.081 2.27 - 4.0 54 54 122 219 72 72 163 292 F 19A-19bstp 0.049 1.08 0.58 54 58 31 72 72 77 41 61 AED .1. 0 Emelope lossigain 1 898 867 1573 1490 12 a) Wfibation 245 69 456 128 b) Racal venblation 0 0 0 0 13 internal gaim: Occupants @ 230 a 0 0 0 Appliancedother 0 7000 Subtotal (lines 6 to 13) 1143 936 2028 SSW Less edernal load 0 0 0 0 Less hansfer a a 0 0 Reolistri-bution 0 a a 0 14 Subtotal 1143 W6 2101 Was 15 Duct loals Zr/. 18%1 303 171 27% 181% 538 1568 Tctal :=n load 1446 1 1107 2%6 10176 Air required (cfm) 129 49 228 450 Calculations approved by ACCA to meet all reciuirements Of Manual J 8th Ed. -PW 2019Apt-25 10-.38:00 Atk Right-Sulte(D Lhh�al 2010 18.0.31 RSLD8101 Page 2 ... nets%VWdghlsoff HVACWTKENS HAMER 2ND FLR.np Calc - MJB BuiTcrmg Fmt faces: S wrightsoft Right -AD Worksheet Job: Date: Apr25,2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 I= T72-466-6796 Ernail: QUICKCAUCS@AOLCOM I Rcornnamne BATH 2 E)Vosed wag 17.0 It 3 Room height 10.0 It heaVocd 4 Rcorn climensim 6.0 x 11.0 It 5 Rwrnzuea 68.0 fl. TY Construction U-ualue Or HTM AM (Ift?) Load Am Lead nuniber (ftHWF) (Bftfflt2) a perimeter (11) (Btuh) or perimeter H�� �Ced GIms NIF/S Heat cool Gress WKS Heat cool 6 w 12B-Osm 0.122 n &42 294 110 110 376 323 Y—G 12B.Osm 2 gl&ng. clr lowe 0.122 0.650 a a &42 IEL20 2-94 33.77 60 8 52 0 178 146 153 270 w 12B-Osm 0.122 a 3.42 Z94 0 a 0 a I w 121110sm 0.122 w 3,42 294 0 0 0 0 C 1613-11find 0.081 - 227 4.05 66 66 150 257 F 19A-l9bSIP 0.049 - 1.08 0.58 66 68 71 38 6 c) AED =Lffs'cm is Emelcpe Imsfgain 920 1067 12 8) MitratiOn 199 56 b) Reant%eftlatim 0 0 13 Internal gains: Occupants @ 230 a 0 AppIkMC8V&ff 50 Subtatal (flnes 6 to 13) 1118 1173 Less culennal load 0 0 Less transfer RecrLitnbution 14 SuIAcW 1118 1173 15 Duct leads 2M 18% 296 214 Total roenn load 1415 1386 Air required (dm) 126 61 Calculations approved by ACCA to meet all reciulrements of Manual J 8th Ed. -Fk- 2019-Apr-25 10-.36:00 A&K Right -Suite@ Unh�al 2018 10.0.31 RSU08101 Page 3 --- natsWrightsolt WACWTKENS HAMER 2ND FUR.wp Cale - MUB Building Frent f3cm: S wrightsoft. Duct System Summary Endre House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCF, FL 34946 Phme: T72466-6799 Far 772-46M796 Eina: QUCKCALCS@AOLCOM Project Information For. AITKENS RESIDENCE- 2ND FLOOR ADDITION 15354 NAVION DRIVE, PORT ST LUCIE, FL E)demal static pressure Pressurelosses Available stadc pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heafing 1.00 in H20 0 in H20 1.00 in H20 0.50010.500 in H20 1.000 WIWI: 800 cfm Job: Date: Apr25,2019 By: Cooling 1.00 in H20 0 in H20 1.00 in H20 0.500 / 0.5GO in H20 1.000 inil 0011 800 Cfm 172 ft I Supply Branch Detail Table Design Htg CIg Design Diam HxW Duct Actual I Ftg-Eqv Name (8tuh) (cfm) (dm) FIR (in) (I n) Mati Ln (ft) Ln (ft) Trunk BATH h 1415 126 61 1.000 6.0 0XID RtFg 34.0 130.0 sti EXIS'nNG-A C 10176 228 450 1.000 120 OX0 RtFg 31.1 130.0 stl OFFICE h 1788 159 120 1.000 7.0 0XID RtFg 30.0 140.0 sti OFFICE -A h 1788 159 120 1.000 7.0 OX0 RtFg 22.0 150.0 sH WIC h 1446 129 49 1.0001 6.0 OxO RtFg 9.0 160.0 sH I Supply Trunk Detail Table Name Trunk Type Htg (Cfm) 61g (Cfm) Design � FIR Veloc (fpm) Dim (in) HxW Cin) Duct Material Trunk stl Peak AVF 800 800 1.000 868 13.0 0 x 0 RectFbg Return Branch Detail Table I Name Grille Size (in) Htg (cfm) � Cig (cfm) I TEL (ft) IDesign FR Veloc; I (fpm) Dim I (I n) HxW I (I n) StudlJoist I Opening (in) Duct I Matl Trunk I rb1 OX0 8001 8001 0 1 01 01 01 ox 0 1 1 RtFg I -F�- wrightsaft- 20`19-Apr-25 10-.38:00 At. Page 1 RigiTt-Suiteg)Lkfl�a]20181&0.31RSLNDBIOI "Irm ...'etsAWrIghtsoft WAMAITKENS HANGER 2ND FUR.ntp Cedc=Mja BuRcringF=tf�:S