Roof Plan
scale: 1/8" = 1'-0"
SV Crimp (26 ga.) roofing
panels over Peel & Stick on
Lln
d.x. plywood fastened
iling schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
R20 SprayOthers
Foam Insul.See Connector
Schedule
Z x 4 p..t. 2 x 4 24"o.c.
Cont.
9'-4"-J$-- T.O_B_ - — -
5/8" d.w.J
1 x 4 p.t.
Firestop
Two Course Perimeter
Beatri with (1) #5 Rebar
in each course, Filled
with Grout
1 x 2 p.t. furring
strips 24"o.c. ---\
with R4.1 Foil
insulation
1/2" d.
#5 vert. rebar in
grout filled cell
See Floor Plan
for Locations
4" 3000# Fibermix Colic.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill --,.
0.00'*- F_F.E ---
v —
(2) #o
Rebar
Galy. Drip Edge
over 1 x 4 p.t.
�I
I
2 x 8 Cedar
Fascia Board
Stucco Soffit Over
High Ribbed Wire
F-6" Lath
Install one layer of 15#
felt to framing prior to
installing wire lath
8x16x8
CMU Typ.
Hardie Plank Siding
fastened to CBS block
as per Product Approval
#5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
Stucco Stop
v I Grade
0
r.
Typical Wall Section
0
(V
Area Tabulation
Living:
1426
Carport:
272
Porch:
207
Entry:
213
Total: 2118
Cubic Volume: 13,305 c.f.
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
A^N Q"
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 2118 s.f.
Building Code
6th Edition Florida Building Code: Residential
2014 National Electric Code NFPA 70
Scope of Work
New one level CBS single family
residence
Project Data
Project Name: Evan Miller
Street Address: T.B.D.
City: Ft. Pierce
County: St. Lucie
State: Florida
DesiLyn Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: N.A.
Wind Speed: 160 MPH
Wind Importance Factor: L0
Building Category: II
Wind Exposure: C
Internal Pressure Coefficent: .18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
oo
----------------------- 1014 --------------------
I
-- ° El
�
I
I
I
I
�
�
I
�
L-$
L-$
o
=
Carport
❑
o ----
------
------
o 0
a
=
L-1
i 9'-4" Ceiling
from F.F.E.
Porch
i
9'-4" Ceiling
from F.F.E.
L-4
N
I
0[Ell10
ion
11EAEl
•❑
Temp. Glass
Enclosure'(,.h.
V.LI'.
d..
co
in
�
w a an I
t` pan I
m
1
-
to
I
o
o
I
o
H32 s.h.
SafeGlass
v
^
Air Handler
I w.
in Attic
Optional
_
m
'o c
•
❑
L_—_J
Cabinet
w"
Bdrm. 3
in
Fla
o 0
AV
ILre
--- -----
Ref.
L-3
9'-4" Ceiling
❑•
�n
25
_
o
--- i
N
N eT--
�
Pantry
�
s.h.
Egress
2Ac x 36 �
21
Access I
Kitchen
L-1
5068
I 9'-4" Ceilint;
o
❑
AC Cond. on
Cones Pad
8
4'-8"
3'-2'
2' �0" 2'-1" 1'-6" -
12'-3"
3'-4" 8'-4'
8"
dw
' 0 ----J
Dining
5068
Range &
M
i o Exh. Hood
9'-4" Ceiling
o
d
N
1'-6"
�'
HB
I-IB
can
1�1
Header I
at 96"
v
m
a.f.f.
9'_4"
L-2
El
II
Clog.s.
o
Nn
m
ti�b� n
h.
Safety
Glass
bb _
O
� N
N
•
4068
8
71, 8
17'-4"
3'-4" 2'-6"
5.10„
El
a
o
Master
Bdrm.
Great
ROOM
o
o
9'-4" Ceiling
9'-4" Ceiling
B drm. 2
Fl
9'-4" Ceiling
L-1
25 Egress
Egress
L_3 L 1
25 1 1
I
m
Entry
s.h.
E es
Egress
Q
L-5
i
9'-4" Ceiling
j
I
from F.F.E.
I
o------------
------------ o------------
------------ o------------
------------ E71 ------------
------------lo
U
M
OH
�
�
of
0.
tjD
O
•�
U
w
Ln
00
r,
•r..4
Cn
U
W
O
f�ll
v
CA
CA
r^�,
v
CCU
r--q
E-"
-e�
a/
00
m
U-J 1, 6 L-6
5'-7" 5'-3" 5'-3" 5'-3" 5'-3" 5'-3" 5'-3" 5'-7" .7009
la'-lo" Ia-6" 1a-6" la'-lo° AINnoo 31oni
3o- . 3u l3131
Floor Plan
AY "31 201
ST. Lucie County, Permitting
�i
O
w
W
�
U
N
w
w
W
�
(D
z
drawn
s.l.
checked
s.l.
dare
5/_t,i19
scale
as noted
job number
18078
'tAN'04hii')
sheet
lily
A_ 1.
n
AdOO 311:1
T.O.B.
6 $„ -0�— Window Head
0.00'-0-F.F.E.— —
Left Elevation
scale: 14' = 1'-0"
Right Elevation
scale: 1/4" = l'-0"
PRODUCT APPROVAL
Approval
Product
Model Number
Manufacturer
Glass
Attachment Method
Building Rated
Product Rated
Number
Type
Design Pressures
Design Pressures
SH-5500
Per Manufacturers Product Approval
FL#: 239.6
Windows
singlehung
PGT Industries
Impact
3/16" Tapcons with 1 1/4" embedment in Cone.
+33.5 -44.8
+/- 50.0
in Mfg. supplied holes
FL#: 17184.5
FL#: 17184.9
Swing Doors
Fiberglass
Door
J?]astpro
Impact
Per Manufacturers Product Approval
+33.5 -36.3
+/- 50.0
Approval
Number
Product
Model Number
Manufacturer
Attachment Method
Building Rated
Product Rated
Design Pressures
Design Pressures
FL#:17443.1
Roofing
5 V Crimp
JA Taylor
Per Manufacturers Product Approval
-65.2
-129.25
FL#: 10892.1
Siding
Hardie Plank
James Hardie
Per Manufacturers Product Approval
-50.0
-92.0
FL#-9777.7
Roofing
Underlayment
Weatherl-ock Specialty
Owens Corning
Per Manufacturers Product Approval
Front Elevation
scale: 1/4" = 1'-0"
Rear Elevation
scale: 1/4" _- 1'-0"
4'
3 1 2 1 3
3
2 1 1 1 2 2 1
II — — — — — — — — — — L
I I
I
I I
12
I 1 I y
2 I I
I I
I I
--I----------------------I--
3 2 v I 3
I
3 i 2 v 1 3
--I-----------------------I--
I I
I I
I I
2 1 1 1 2
I I
I I
I I
I I
1 12
I I
--I------------------------I--
3 1 2 1 3
Wind Zones - Roof
CU
F"
^
Z
CNo
�
�
M
F
�
w
Z
•un
U
w
W
Q
ct
0
r l
C7
E
Z
O
ll
Q
C�
v
W
O
U/�
r�
c�
'--�i
>
00
CIA
Q
a/
00
M
w
W
U
7�
i—I
.r,
O
Attic Vents Calculation
�
�
—'
w
CARPORT, PORCH, ENTRY
Attic Area: 692 s.f. / 150 = 4.6 s.f required.
O
soffit area = 89.41.f. x 1.3 = 119 s.f
w
w
U
W
a
Venting Provided:
8 x 16 soffit vent: 85 sq. in. each vent
v
8 Vents along overhang = 680 sq. in.
680 sq. in. / 144 = 4.72 s.f.
Total Ventilation Provided: 4.72 sq. ft.
Wind Zones - Walls
drawn
s.l.
checked
s.l.
date
5/5/19
scale
as noted
job number
18078
sheet
A-2
E
O
U
Ri
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Nao
U
LL
0
a_
Cast Crete Lintel Schedule
All Rebar to be #5 Grade 60 min.
MARK
LENGTH OF
LINTEL
ALLOWABLE
GRAVITYLOAD
APPLIED
GRAVITYLOAD
ALLOWABLE
UPLIFTLOAD
APPLIED
UPLIFT LOAD
BEAM SPECS.
L-1
4'-6"
11809
1524
5861
415
SF321B/lT
L-2
3'-8"
11809
118
6627
34
8F321BAT
L-3
4'-8"
3966
1524
4594
415
8RF301B/lT
L-4
4'-4"
10893
967
6183
264
8RF301B/lT
L-5
5'-8"
4360
118
2093
34
SF161B/lT
L-6
10'-6"
1533
113
914
184
8F161B/lT
L-7
10'-0"
1533
118
914
34
8F161BAT
L-8
10'-4"
1533
937
914
220
817161B/lT
L-9
10'-8"
1366
671
798
202
8F161B/IT
L-10
12'-8"
1075
118
606
34
81`161B/lT
L-11
5'-O"
5365
118
2290
34
817161BAT
Mim. Beam depths shown, beams may be increased without comment
Ar —al
at boiry of reba,
atboaan of fI IinvA
F—fill,, av,ry
IIr
W
bar et boom
Iof
8F16-1B/1T
nomn d
bar at mp
518ryof#5�
lintel cavity
hugvh
Lintel Type Designation
Safe Load Table Notes
1. All values based on minimum 4" nominal bearing.
Exception: Safe loads for unfilled U lintels must
be reduced by 20% if bearing length is less than
6 1/2".
2. N.R. = Not Rated
3. Safe loads are superimposed allowable loads.
4. One #7 rebar may be substituted for two #5
rebar in 8 inch U lintels only.
5. All safe loads in units of pounds per linier foot.
6. All safe loads are based on simply supported span.
7. Safe load ratings based on rational design analysis
per ACI 319 and ACI 530.
Cast in Dlace sill or Tie Beam Option
Composite U Lintel Materials
1. Grout per ASTM C476 fg=3000 psi with maximum 3/8
inch aggregate and 8 to 11 inch slump.
I. Rebar per ASTM A615 Grade 60
3. Concrete masonry units (CMU) per ASTM C90 with
minimum net area compressive strength = 1900 psi
4. Mortar per ASTM C270 Type M or S
Installation Notes
1. Installation of U lintels must comply with architectural
and/or structural drawings.
2. U lintels can be field cut to the required length.
3. Cast ill place concrete may be provided in composite
U lintel in lieu of concrete masonry units.
4. The exterior surface of U lintels installed in exterior
concrete masonry walls shall have a coating of stucco
applied in accordance with ASTM C-926 or other
approved coating.
5. Concrete masonry units used in composite U lintel shall
be laid in a running bond.
6. Shore composite lintels as required.
7. U lintels are manufactured with a 5 1/2" long notch at
both ends to accomodate vertical cell reinforcing and
grout.
In the event that precast products are damaged in the
field cast in place sills and tie beams may be used (not
to exceed 5'-10") Typical cast in place tie beam to be
a min. 8" x 12" with (2) #5 top and (2) #5 bottom
FORMWORK & SHORING
No structural concrete shall be stripped until it has reached
at least 80% of the 28 day design strength.
Design, Erection, & Removal of all formwork, shores, & reshores
shall meet the ACI Standards 347 and 301
Contractor to verify all building setbacks prior to the start of
construction. A formboard survey shall be submitted to the building
department for approval prior to pouring concrete.
Dowel Rod Repair Note
In the event vertical steel has been omitted from the down
Vpour locations, drill 5" into concrete (no closer than 3 3/4"
rom edges and 5" from ends of cap walls) Remove dust
per manufacturers instructions and use Two hart eppoxy to
anchor the #5 rebar in place. Use either "Hilo C-I%" or
Simpson Epoxy -Tie.
SOIL STATEMENT:
Foundation has been designed for a soil bearing capacity of 2000 p.s.i.
Fill shall be laid in layers of 6". Each layer to be compacted to 95%
compaction.
If the contractor encounters, while digging the foundation, any
discrepancy to suggest the soil may be ma leeuate, he must
immediately report it to the owner and the Architect or Engineer
so as to order a soil boring test.
GENERAL FOUNDATION NOTES
Concrete shall be a minimum of 4" thick over clean, compacted,
termite treated fill and 6 nil] polyethylene vapor barrier.
If concrete slab contains 6" x 6" 10/10 W WM provide 1" coverage
Concrete shall have at minimum compressive strength of not less
than 3,000 p.s.i.
All 90% hooks are to be extended ] 0" minimum beyond the turn.
Field bends are to be done cold and the diameter of the bend,
measured on the inside of the bar, is not to be less than six
bar diameters.
Minimum coverage for rebar shall be 3" in footings and 1 1/2" in
bond beams. Hooks may be rotated horizoniuilly if required to
achieve minimum coverages.
Rebar overlap shall be 48 bar diameters. 30" for #5 rebar
The foundation design assumes that the soil has a minimum
load carrying capacity of 2000 p.s.f.
In the event the soil bearing capacity falls below 2000 p.s.f. This
foundation plan may be superceded by Foundation Design Engineer.
Satisfactory compaction test of fill does not verify lower soils are
adequate.
All specifications and dimensions to be verified by contractor_
All exterior slabs shall slope a minimum 1 /8" per foot for drainage
Connector Notes:
Do not substitute connectors
Do not sheath trusses before all straps are in place
Attach valley trusses and piggy back cusses, if present,
to main trusses per truss manufacturer drawing.
Truss to truss connection by truss company, installed
per manufacturers specs.
Lateral forces perpendicular and parallel to wall has been
considered (less than 300 p.l.f.)
Contractor to approve temporary bracing to prevent toppling
of trusses, see HIB-9.
Other specs, if different from above, have priority.
A.T.R. = All Treaded Rod
Drill and Epoxy Set all A.T.R.
Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy
Provide equal number of studs under girders equal to
the number of plys.
Connector Schedule
Truss
Bearing
Truss
Connector
Qaty.
Connector
Fasteners
Point
Uplit
ID
Uplift
All trusses
Each
to CBS
Brag.
<1000
HETA20
1
1810
(9) 10d x 1 1/2"
Developed from the Truss Placement Plan and Engineering
Sheets prepared by A-1 Roof Trusses. Job Number 75539
Dated 3/25/19
Missed Tie Down Strap Note
In the event the Tie Down Strap has been omitted from the
Layout location, install one NITS 18 strap at the proper location.
Fasten with (4) 1/4" x 2 1/4" Hex Head Titen screw to C.B.S.
and (7) 10d to truss. MAXIMUM UPLIFT 1000 lbs.
F-1
0F1
F-1
00
r— — —
I
— — — — —
— — — — —
I
i F_I
I
I
1
I o
N
I
I
I
F-1
F-1
F-11
L---
------
-----
--------�
o
I
1
a
31-8" T-s„
I
1
I
Z
I
I
_4,'
I
o
F-1
f-2 0 0 o F-2 0 0 4„
�a
— — — — — — — — — — — — — — — — — — — — —
a r — r— — I I
o
I I I
M
M
F-3 I F-2 0 0 0
F-2 ❑
1
4„ I I F-2I— — — — — — — — — — — — -
M
--} I
—J L---- ----_J I U
4" 2500#
I I
cone. pad
I 1
0
1 � I
1 ❑
8, 13- 0" 13'- V �
I
n
F1 I F-1
-1
0
1
p I II I m
I ii I
I
I
o
M
I II I o
I I
-
o
I 4" 3000# FIBERMIX CONC. I
1
M
OVER .006 VAPOR BARRIER I O
o
I ON CLEAN, COMPACTED, I
n
1 TERMITE TREATED FILL I
I I
I ASSUMED F.F.E. 0.00'
❑
1
I l
I 1
F-1 j I
I I
❑ I I
I
I ❑
I 1 .
I I
I
n
I
I F-I
L---------------------------------------------------1
o
O 0 O F - 2 no1i O F 2
❑ o 0 o a o
I 4?'
I 3_q3,�,� 1
F-1 I o F-1
L------------_---
----------------------------------1
n
o F-1 F-1 no F-1
I I , o
Foundation & Footing Flan
scale: 1/4" = 1'-0"
F-1
F-2
F-3
18" x 18" mono. footing
18" x 18" mono. footing
with (2) #5 rebar cont,
8" x 8" thick edge
with (2) 0 rebar Cont.
with (I) #5 rebar Cont.
4"
18'
4" 4„
4„
4'
4„ •
18"
I T .
8"
MONO. EDGE FOOTING
18
SHOWER EDGESTEP
FOOTING
FOOTING
V
M
E
a
w
z
I
•�
w
00
QCA
9_
•�
L/1
W
U
U
UQ
t7
�o
�
Q
7t
t
�
v1
_v
H
W�
CC
ter,
N
00
CC3
a/
pp
m
O
w
w
�
U
a
w
w
�ll
C7
z
to
drawn
$1
checked
s.l.
date
5/5/9
scale
as noted
job number
18078
sheet
A-3
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY FILE COPY
BOCC
Ceramic Tile
Shall be installed in accordance with ANSI A108.1, A108.4, A108.5
A108.6, A108.11, A118.1, A118.3, A136.1, & A137.1. Fiber mat reinforced
backer shall be used behind wall applied ceramic tiles in the tub
and shower areas and conform to ASTM C 1325. Per Durock,
cement board exceeds ASTM C1325.
Gypsum Note
Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047
C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential
code. Per USG, Wallboard conforms to C1396.
Gypsum Board & Gypsum Panel Products
Gypsum board and gypsum panel products shall be applied
at right angles or parallel to framing members. All edges and
ends of gypsum board and gypsum panel products shall
occur on framing members, except those edges and ends that
are perpendicular to the framing members. Interior gypsum
board shall not be installed where it is directly exposed to
weather or to water.
Wall and ceiling gypsum board shall be fastened with screws
spaced at 12"o,c. Screws for attaching gypsum board and gypsum
panel products to wood framing shall be Type W or Type S in
accordance with ASTM C1002 andshall penetrate thewood not
less than 5/8" inch (15.9mm) Gypsum board and Gypsum panel
products shall be attached to cold formed steel framing less
than 0.033" (lmm) thick shall be Type S in accordance with
ASTM C1002 or bugle head style in accordance with ASTM C1513
and shall penetrate the steel not less than 3/8" to 0.112"
(lmin to 3mm) thick shall be in accordance with ASTM C954 or
bugle head style in accordance with ASTM 1513. Screws for
attaching gypsum board or gypsum panel products to structural
insulated panles shall penetrate the wood structural panle facing
not less than 7/16"o.c. (11.1mm).
Gypsum board used as the base orbacker for adhesive application
of ceramic tile or other required nonabsorbent finish material shall
conform to ASTM C1396, C1178, C1278. Use of water resistant
gypsum backing board shall be permitted on ceilings. Water
resistant gypsum board shall not be installed over a Class 1 or
Class 2 vapor retarder in a shower or tub compartment. Cut or
exposed edges, including those at wall intersections, shall be
sealed as recommended by the manufactuer. Water resistant
gypsum backing board shall not be used where there will be
direct exposure to water, or areas subject to continuous high
humidity.
Cold Formed Steel Note
Cold formed steel framing supporting gypsum board and gypsum
panel products shall be not less than 1 1/4" (32mm) wide in the
least dimension. Non Load bearing cold formed steel framing
shall comply with AISI S220 and ASTM C645, Section 10. Load
bearing cold formed steel framing shall comply with AISI S200
and ASTM C955, Section 8.
Wood Framing Note
Wood framing supporting gypsum board and gypsum panel
products shall be not less than 2" (51mm) nominal thickness
in th least dimension except that wood furring strips not less
than 1" by 2" (25mm x 51mm) nominal dimension shall be
permitted to be used over solid backing or framing spaced
not more than 24"o.c. (610mm)
Wire Lath Attachment
Over wood framing the paper
backed wire lath shall be installed
over one layer of approved plastic
house wrap. Lath shall be attached
horizontal framing members with 1.5"
roofing nails and to vertical wood
framing members with 6d common
nails or 1" roofing nails driven to
penetration of not less then 3/4"
of an inch, or 1" wire staples
driven flush with the plaster base.
Staples shall have crowns not less
than 3/4" and shall engage not less
than three strands of lath and
penetrate the wood framing members
not less than 3/4". The fasteners must
penetrate the wood framing members
not less than 3/4". Fasteners shall be
711 o.c. max.
9. x 4 hmt.. r,,M hrarin ,
10'-0"
Bottom Cord Lateral Bracing
2 x 4 diagonal "X"
bracing at 8'-0"o.c.
starting from ridge
with (3) 12d each
end
2 x 4 blocking at 4'-0"o.c.
starting from ridge between (2) 12d trusses 24"o.c.
both top and bottom cords sees out
for two truss spaces from y
gable end
See truss shop -
drawings
Continuous 2 x 4 Lateral
bracing at 1/3 points of
span. Nail with (2) 16d
each truss btm. cord
Continuous 2 x 4 bracing
fastened to beam with
5/8" x 6" wedge bolts
with 1/8" x 2" washer 24"o.c.
Gable End Bracing Detail
Alum, window
frame
3/8" continuous bead of
caulk (back bedding) behind
shim to prevent liquid passage
1/4" struct. shim
set flange in continuous
bead of caulk across the
entire face of buck
perimeter caulk
stucco finish
Galv. drip edge
min. 4" lap
1 x 3 p.t. over 2 x 6
Paint Grade Fascia
Gable end truss
by truss mfgr.
19/32" c.d.x. plywood
with 8d nails 4"o.c.
Cover with House Wrap
2x "L" web stiffener
as required by the
truss mfgr.
"Simpson" RETA16 truss
to bond beam with (14)
10d x 1 1/2"
located at each truss
vertical
Concrete Bond
Beam
corrosive resistant
Tapcon concrete
stews installed as
specified in window
manufacturers product
approval
,-window sill
a
Gunable sealants shall comply with
ASTM C 920 Class 25 grade or
greater for proper joint expansion
and contraction
precnst
cone, sill
Typical Precast Conc. Sill Detail
3/8" continuous bead of
caulk (back bedding) behind
buck to prevent liquid passage
set flange in continuous
bead of caulk across the
entire face of buck .. %
ww �
8� °
a� ab
00 O° a
0
�c00� °..
CBS
Min. 1 1/4" embedment
a at windows and min.
1 1/2" embedment at
a ° ° sl. gl. doors
a
4 °
`1/2" drywall
stucco finish J
perimeter caulk J/
Attach p.t. bucks
1/4" max. struct. shim
with 8d coil nails at
caulk
12"o.c.
attach as per
Typ. Alum. window
manufacturers
jamb or sliding glass
product approvals
door jamb
NOTE: Method of attachment and
Gunable sealants shall comply with
waterproofing procedures are the
ASTM C 920 Class 25 grade or
same at poured concrete sill.
greater for proper joint expansion
and contraction
Coat Bucks with DryLock Waterproofing
after they have been installed and Chaulked
Window & Door Flashing Detail
at CBS Wall
Includes Buck Attachment Method
GENERAL ROOFING NOTES
Roofing to be composed of and attached to pre manufactured
wood trusses as follows:
Felt underlayment (min. ASTM 0 226 Type II) with 4" min. side and
end laps, fasten with coorosion resistant annular ring shank nails
at 6"o.c. in laps and in staggered rows spaced 12"o.c. in field.
If roof pitch is < 4/12 install (2) layers 15# felt.
If roof pitch is 4/12 or greater, install (1) layer 30# felt.
19/32" plywd. sheathing or equal installed with staggered 'oints & GI clips,
nailed to trusses with 8d corrosion resistant annular ring sliank nails
spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends.
All roof trusses are to be pre -manufactured assemblies provided by
a licensed wood truss fabricator with seperate drawings and data
prepared for actual project conditions by a Florida registered
professional engineer certified for truss design. Any deviation from
the proposed plans as shown regarding placement or bearing shall
be brought to the attention of the truss engineer prior to fabrication
of the trusses. The truss manufacturer's certified layout shall govern
after fabrication.
The handling, erection, and fixing of wood trusses shall be in
accordance with the specifications contained on the certified mfgr's.
drawings and data.
All engineered headers and truss hangers to be provided by the
truss manufacturer.
Splitting or cracking of structural components due to installation of
hardware is not permitted.
Unless otherwise noted, the installation of specified hardware shall
conform to the truss manufacturers installation instructions and
standard practice.
BUCK ATTACHMENT NOTES
AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS
TO BLOCK WITH 1/4" DIA. TAPCONS WITH 1 14' EMBEDMENT
INTO C.B.S. SET A 6" FROM CORNERS AND AT 12"o.c. MAX.
AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH
BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS
OR "T" NAILS" 4" FROM ENDS AND 12"o.c,
USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION
SHEATHING NAILING NOTES
Nailing Pattern
Zone 1: 8d at 6"o.c. field & 4"o,c. edges
Zone 2: 8d at 4' o.c. edges & fiold
Zone 3: 8d at 4"o.c. edges & field
Pneumatic Nails
Pneumatic or mechanicaly driven nails will
be accepted under the following conditions:
Min. nails size 8d or larger ring shank with
Min. shank diameter:.113
Min. Length 2"
Min. Head Diameter:.280 Full Round
Min. Ring Diameter .012 over shank dia.
Min. 16 to 20 Rings per Inch
Note
Gun nails shall be permitted as an
acceptable fastener from any manufacturer
Wood screws meeting the same size requirement
may be used in lieu of nails widiout comment
Nailing Schedule
ROOF & FLOOR DIAGRAM
Use sheathing with #8 gun nails at 6"o.c.
at supported panel edges and #8 gun
nails at 6"o.c. at intermediate supports.
ROOF SHEATHING TO GABLE END FRAME
Use #8 gun nails at 4"o.c.
EXTERIOR SHEATHING
Use #8 gun nails at 4"o.c, at panel edges
and #8 gun nails at 4"o.c. at panel top and
bottom and 6"o.c. in field
THRESHOLD NOTE
At egress door (see floor plan) the max. hgth.
of the threshold shall be 1/2"
comer bars at beam
(outside only) (2) corner
bars at footing (min.) —
vert. dowel lapped with
wall reinforcing, all
laps 25" (min.) in grout
filled cell
all corner bars to be the
same size, number, and
Il spacing as horizonti i bars
t in footing, beams, and walls
Corner Reinforcing Detail
STRUCTURAL NOTES:
All reinforcing steel shall be high strength billet steel and shall
conform to ASTM A-615 grade 60 specifications. Lap continuous
reinforcing 48 bar diameters or 30" in beams and in slabs. Lap
bottom steel over supports and top steel at midspan. Hook
discontinuous ends of all top bars. Reinforcing steel shall have
a minimum of 1" concrete cover, or as follows:
BOTTOM TOP SIDES
Beams: 11/2" 11/2" 11/2"
Slab on Grade: 1 1/2" 1" _
Structural Poured: 3/4" 3/4"
Poured Walls: 3/4"
Slabs exposed
to the weather 3/4" 1"
Reinforcing steel shall be detailed and fabricated in accordance
with the "Manual of Standard Practice of Detailing Reinforcing
Concrete Structures" and the current "ACI Building Code 318'
All structural steel shall conform to current ASTM Specification A-36
All wood in contact with masonry shall be pressure treated or approved
seperating material.
All dimensions shall be verified in field by the contractor. If there are
any discrepancies the Architect or Engineer shall be notified before
proceeding.
No slum over 5" shall be permitted for any structural concrete without
the Architect or Engineer approval.
All Design and Construction shall be inaccordance with the current
American Concrete Institute (ACI). and the American Institute of Steel
Construction (AISC), The Florida Building Code and all applicable
local codes.
Structural Concrete shall attain a minimum ultimate compressive strength
(Fc') in 28 days as follows:
Column Footing and Wall Footing: 3000 p.s.i.
Column and walls from foundation to roof: see column schedule.
All other concrete: 3000 p.s.i.
Footing sizes and reinforcing are based on allowable soil bearing
capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this
is not the case, the Architect or Engineer shall be notified before
proceeding with the work.
Timber (Heavy Timber Construction)
(a) Truss manufacturer shall submit a signed and sealed shop
drawings by a registered Engineer.
(b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i.
(c) Roof members should be secured to the beams or other
structural components with hurricane anchors for wind uplift.
All wood members shall have a minimum fiber stress in bending
of 1200 p.s.i. with 1/360 max. deflection.
All bolted connections shall be 1/2" Cadmium plated or better.
Lag bolts to be used only in shear connections with minimum
4" threaded penetration past steel plate.
Lag bolted conditions shall be drill tapped no larger than the
internal thread diameter and shall not be hammer driven.
Under Girder Trusses provide equal number of studs as girder
plys at frame bearing locations
GENERAL REQUIREMENTS
All work to be as per the current edition of the Florida Building Code
and meet or exceed all applicable local requirements.
General contractor is responsible for all labor, materials, utilities, testing,
waste removal, storage, securing of site, accomodation, transport/freight,
and all other cost related to the completion of this project., unless explicitly
identified here.
Owner is responsible for all municipal related charges such as impact
fees, and water connection, except building permit fees, which are to be
included in the construction bid,
General contractor to check all drawings for errors and ommissions and
bring them to the attention of the architect prior to starting any work, or
ordering any materials of the respective division of work. If such errors
and ommissions are not reported in writingto the architect, any resulting
damages or costs shall be born entirely by the general contractor.
Architect is not responsible for the contractors method or means of
construction.
General contractor is to keep the site in a clean and safe state through
out the course of construction. On building turnover, general contractor to
clean all surfaces so as to be free of dust, grease, stains, scuffs, etc.
Unless otherwise noted, the installation of specified hardware shall
conform to the manufacturers instructions and standard practice.
All plans and drawings are not considered complete until they have been
reviewed and approved by the St. Lucie County Building Department
and the building permit has been issued.
EXTERIOR CEILING & SOFFIT NOTE
7/8" Stucco finish over 3/8" high ribbed galv. wire lath fastened to
framing members with No. 11 guage nails with 1 3/4" embed. with 3/8"
dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. Provide one
layer of 15# felt to framing prior to installing wire lath.
INTERIOR WALL FRAMING NOTE
Interior non bearing walls to be 2 x 4 studs 24"o_c.
Spruce, Pine, Fir (SPF) #2 Grade lumber or better
or metal studs (25 Ga.) Crimper may be used in
lieu of screws.
H
E-
z00
N
E�
a
w
to
U
In
�'
a
so
U
w
0
n
�
�
W
U
U
C�
A
U
p
U
Z
O
A
�
a)
�
`�
U
W
.
t\
W,
UoZ
00
cn
W
.b
U
w
w
�
4-;
z
rn
drawn
ai.
checked
s.l.
date
5/5/19
scale
as mued
job number
18078
sheet
A-4
R
V VVyle MpL Aoc
GopE cle G0UN
LAV
SOT S®co FILE Copy
Show
Plumbir
water ha
each fix
Insulate all hot water lines
Plumbing Riser Diagram
PLUMBING NOTES:
to sewer
system
Plumber to consult with contractor and equipment ordered
for rough in dimensions.
Verify all dimensions with the floor plan. The floor plan
dimensions dictates all other dimensions on other sheets.
Do not scale drawings, if any conflicts arise, contact the
Architect or Engineer for clarification prior to construction.
All sanitary lines 2" or less shall have a slope of 1/4" per
foot minimum.
All sanitary lines above 2" shall have a slope of 1/8" per
foot minimum.
Provide Anti -Scalding Valve in all showers
Lowest living area floor elevation (refered as 0.00') to be
set by a professional land surveyor to the required building
department elevation, but not less than 18" above the crown
of the road.
a.
(3) #3/0 (THW) copper
and (1) #4 ground (THW)
copper in 2' galy. conduit
Panel: 150 A.M.C.13
1 A 3W 40 Circuit
120/240 Volt
disc.
5/8" dia. x 10'-0"
long ground rod 3/4" copper
water pipe
10'-0"
150 Amp
Panel
(3) #3/0 (THW) copper
and (1) #4 ground (THW)
copper in 2" galy. conduit
F.P.L. service
P.L.
overhead
Wall service)
150A meter
;�t, 015G -
(3) #3/0 (THW) copper
and (1) #4 ground (THW)
copper in 2" galy. conduit
F.P.L. service
(if underground
service)
I— -
IL
r tie ground wire
to footing rebars
Electrical Riser Dinyram
Electrical Load Calculations
1426 Living S.F. at VA
4278 watts
Two 20 Amp Appliance Ckts.
3000 watts
One Laundry Cir. @ 1500 watts
1500 watts
One Range
9000 watts
One Dishwasher & One Disposal @
1500 watts each 3000 watts
One Microwave @ 2000 watts
2000 watts
One Water Heater @ 4.5 kw
4500 watts
One Dryer @ 5 kve
5000 watts
One Ref. @ 1500 watts
1500 watts
Two Baths @ 1500 watts each
3000 watts
One Well Pump
2025 watts
Total 37,803 watts
First 10 KVA at 100% 10,000 watts
Remainder at40°/h 11,121watts
Total 21,121 watts
One AC Heat at 100% 10,000 watts
Total 31,121 watts
31,121 W / 240 V = 129.6 Amps
Use 150A Service
Smoke detectors wired to 120V Bathroom lights
Non Switchable, Not GFI
Electrical contractor to verify all equipment loads prior to
start of construction. Electrical contractor to recalculate
electrical schedule it loads are to be modified
Electrical Notes
1. All loads to be checked by a Florida Licensed Electrician
2. All work to meet the National Electrical Code
3. Calculations and panels below are for sizing conduit and overall
building load requirements only
4. All conductors to be copper; all insulation to be THHN. Conduit as
follows: PVC below ground, Rigid from underground to service box
for exterior lights on building; AC, MC, or EMT conduit elsewhere.
5. Ensure min. 36" clear between equipent and disconnects, Typical.
6. Protective ratings shall comply with NEC 110-9 & NEC 110-10
7. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1
Electrical Plan
scale: 114" = 1'4Y
ELECTRICAL LEDGEND
I -
RECESSED LIGHT WITH LENS @ EXTERIOR & WET LOCATIONS
SURFACE MOUNTED LIGHT FIXTURE
F---? i ---�
SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE
UNDER CABINET FLUORESCENT FIXTURE ( INCH LIGHTS )
RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN
CEILING FAN WITH LIGHT OPTION
O
EXHAUST FAN OUTLET
b
CARBON MONOXIDE
DETECTOR
THERMOSTAT DETECTOR
DUPLEX OUTLET - SWITCHED DOOR CHIVIES
DUPLEX OUTLET ® SMOKE / CARBON
S
�
MONOXIDE DETECTOR
220 V OUTLET
_W
SWITCH 4+ TELEVISION
THREE WAY SWITCH TELEPHONE
D
DIMMER SWITCH PUSH BUTTON
NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F.
ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING
OUTLETS THAT ARE NOT GFCI MUST BE AFCI.
TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE
PHASE 15 & 20 AMP BRANCH CIRCUITS
U
h-�
Q
�
M
�
E" l
a
w
g
. ,..t
y
W
U
C)
ct
Q
O
U
C7
o
Meter
r�
r�
E-�
U
F
t
S~
N
U
Z
N
a/
m
Chi
0
w
cC
U
�
z
�
o
�
U
�
ct
�
N
w
w
U
W
a
C7
z
Cn
drawn
S.I.
checked
s. i.
date
5/5A9
scale
as noted
job number
18078
sheet 5
R
ODErO
ME NTY
G 001E
ST • gOGG
E
(OJ
Rl
0
LL
tct
0
0-
lvliLieLL
LL
i
22'8"
20'
I
I
INC—
N
241
'1
.
.
.
-
-
'
fJ 4F
} 7'C
L1> g�P
�kfi,Ld
,
5E
'-VG,'FO
W-S,'
,' ,'
,' ,' ,'
�, �,
,' ,' ,-
.
,CA
5'
2'
18'8"
Ln
m
L
A
NG
@ 4"
iN
2'
2'
2'
N
N
N
N
N
N
N N N N N N N N N 2'
2'
2'
lol
11
W
c- cV N N N N N N N N N N ce) Ln U) to Ln N
i21$n
12
(f,
P-6°
TYPICAL END DE"[ "AIL
*NOTE: ALLTRUSS TO WALL AND/OR TRUSS TO
LEDGER CONNECTIONS BY BUILDER
a L L
(UNLESS NOTED OTHERWISE)
c
0 ° a
c L c r
0 3 L � 0
* NOTE: ALL CEILING DROPS BELOW BEAMO
5 6
BY BUILDER (UNLESS NOTED OTHERWISE)
o m a a o 0
L
c
* NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW
N
L .�
a m 2 `° c
TRUSS I.D. AND TRUSS LOCATION ONLY. THE BUILDING
a
m a — a ~
DESIGNER IS REPSONSIBLE FOR THE STRUCTURAL
v a� m o�� m
STABILITY OF THE ENTIRE STRUCTURE.REFER TO THE
mYE&oaNm
INDIVIDUALTRUSS ENGINEERING DRAWINGS FOR
~ a '00 8 n 2 °
O C
j
GRAVITYAND UPLIFT LOADS.
p tN � D -
Ofs � ° to g w
FOR BRACING & ERECTION DETAILS REFER TO
a cg a aL
BCSI-03 AND/OR ENGINEER OF RECORD
0 y N o a
a a
ED
L `a = a c
LLJ
Ca oEc -.o
REPRESENTS THE LEFT SIDE
n o E � o
® OF EACH TRUSS DRAWING
< 2 � > E .a m•
�� F
G N =Lp
O m N U '`
( NOTE: REFER TO USP CONNECTOR
N .N...0
o m m z & � c -8 Co,
¢
o E'o o m .
T
CATALOG FOR INSTALLATION DETAILS)
c' O� a Um e
-Lo. � o 2a�i'V E
D
A
JUS24
H
THD46
Q---
o a� N L mN
.3
B
JUS26
J
MSH422
R---
o o N N
(�
THD26
K
MUS26
S
---
>.`0L m=
m p E m c O
p
THD28
L
HJC26
T---
L a N a E c
T m L - m
E
THD262
M
---
U
---
E22aaWMoaao
_ c� E
�_ ° o
F
THD28-2
N
---
V
---
O❑ N� C D W��
G
JUS46
P
---
�(
---
� � ° �� 0
N N w L
0 0 0
HBB
HANGER BY BUILDER
BBB
1
BEAM BY BUILDER1
N 3 0~
u
= 3 W
m
cH o oacC on-0
Z
LSTA12 @TC & BC
N= G
z
o o n 0 o E
INDICATED TO BE USED IN
FL °
Zt
LSTA12 @TC
CONCORDANCE WITH
m m @ N ° a .m ,
CORNERSET DETAIL
c a$ o M `o w 2 0
Zbj
LSTA12 @ BC
STDTL01
m a r -o m o «Q
LOADING
ROOF
FLOOR
WIND LOAD
r � `m c''°
c a Y 0 c m N
m
�
LIVE LOAD
30
ASCE 7-10
° ED ❑ o N
ao
020, � F
� U
DEAD LOAD
15
-
160
C
c'7- o �0- '01 ` c a a
5m�y��'�ma'
LIVE LOAD
0
Residential - CAT II
_ ¢
m - m m « 0 >Of
c
0
L
c a m
m U
DEAD LOAD
10
-
Closed
o$
N D 3 z
U
�
m rn a o 3= o L
C ,p = � (0 (0 N
N N
v
TOTAL LOAD
55
-
FBC 2017 RES
y
D o m c a ° N `0
c
o❑ me 0-0 ` y
DURATION FACTOR
1.25
-
TPI 2014
Z
5 a = .N 0 o m
M
N r U Q,- N c N
MAY 31 2019
! ST. Lucie County, Permltting
Anthony T.
N:Mnv
1.9
+A ?�? -'. '-' -$' way. w
• t4o90003a.�
W,
r
��
a �.`
'�R
9ERIAL
4d36b989999e20a51b6cde8
RE
Owr+
e
DATE
BY
REMARKS
u F 0W
OL L C C= 2 C
-
--�--�----
-
w co)_ _ «
o
« c 0.
-N •_'O L
«
E
o _ 2 s o
-
--/-a----
-
o
O
N (0
U
a�n�Uv o'.o Ear
N = 0
N «
N m O m« O w
G "O um .: N O@ N
w
5 L = T 's G a
U� N
a 3 0
It is understood that above ❑ APPROVED
N _ . E
U
conditions have been reviewed &
v ¢ ❑ « N
o E a « c
are acceptable for the fabrication ❑ APPROVED AS NOTED
, L o
U 33
`
at trusses, elevations, pitches,
0° a � m -�1- 2 o m
overhangs, fascias,ceiling ❑ REVISE AND RESU BM17
0 °'- z co a E ; L
elevations/pitches, bearing
c a
F 0 Eo N F, p m
conditions &all detail pertaining ❑REJECTED
m g 8 0 .o o
W ME a❑
to this truss placement plan. No
° C = a
back charges will be accepted
= a= S a m m a
without previous written approval DATE
o,5 o 0 0 N a, 5 N
from an A-1 Roof Trusses
a� d _ TL 9 U
E 2c
y a a o 0
representative. REVIEWED BY
`o E 2 ¢ ❑ '0 30 o
s Z6 c a o2 -� o d m
PLAN DATE
ARCH: /--/---
STRUCT: /--/----
Cp
VV
L O CQLw c.O
.-
CUSTOMER
TREFELNER CONSTRUCTION
N L L > L N
N N a
N G N V
O O D C 9 N
JOB NAME
MILLER RESIDENCE
0
0 v _ 0° a o
(O N �' L= P .o m
O
j c U �'
c O O Z E L
O m - N N
OPTION(S)
m o 9 a c -W-o m
U U L c O c Y 'p� 8 m
.c`F.a `°mw ,
c N
COMMNTY
N m DI O .`
o c To ° v a L
/LOT#
rrim«�mcRoy m
O U O C C N;` 2 t
`O N c' W 2 C H Ow
CITY
a .W 0 N m= Y
COUNTY
0 0 0
a m
BLDG
BLDG
c o° 1O E' R- O
0 a_
TYPE
#
o 0 W y m
ac c o>m�aa«
0 �0o O~md
ro m a m o a)
JOB #
75539
MASTER-
S& 8 M0 a) T a a
R
m -E`u m-0h-E o =
0 C N m 6 a O
F m 30 C CC
u
ne,
DRAWN
SCALE
DATE
0
� _' L as E `o
3/25,119
m
°zML❑WTDSlm
BS
NTS
N
8 � E ❑ &
�
N
❑ o E 3 D a a
Z« "
=A-1 ROOF
E N
���v��Q��*6
j - L
N =
TRUSSES
g € ° m o
e
A FLORIDA CORPORATION
u) � 2°6 9 m 3 00 0
Ph 772-409-1010 / Fax 772-409-1015
o a
http://www.a1truss.com
V rn f- 8 -o = o 0
ii
r——_-----------,
I I
3/12
IL -------------1
I I
I I
I
I
I I I
I I r- I
L__J I
I 6/12
I I
I I
I I
I I
I I
I �
I I
6/12
I I
I I
I I
I I
I I
I I
I I
I----------------------------1
3/12 I
I I
L—--- -------------------------1
Roof Plan
scale: 1/9" = F-0"
5V Crimp (26 ga.) roofing
panels over Peel & Stick on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
R20 Spray
Others
Foam Insul.
See Connector
Schedule
91-41t-$- T.O.B. - — -
5/8" d.w
1 x 4 p.t.
Firestop
Two Course Perimeter
Beam with (1) #5 Rebar
in each course, Filled
with Grout
1 x 2 p.t. furring
strips 24"o.c. —,
with R4.1 Foil
insulation
1/211 d.
#5 vert. rebar in
grout filled cell
See Floor Plan
for Locations
4" 3000# Fibermix Conc.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill —\
0.00' F.F.F.
/12 2x4pA.
Q 6Cont.
2 x 4 24"o.c.
Galv. Drip Edge
over 1 x 4 p.t.
2x8Cedar
Fascia Board
Stucco Soffit Over
High Ribbed Wire
l'-6" Lath
Install one layer of 15#
felt to framing prior to
installing wire lath
8x16x8
CMU Typ.
Hardie Plank Siding
fastened to CBS block
as per Product Approval
#5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
Stucco Stop
Grade
(2) #5
Rebar
Typical Wall Section
Area Tabulation Climatic & Geographic Design Criteria
Living: 1426 Weathering: Negligible Termite Area: Very Heavy
Carport: 272
Porch: 207 Flame Spread Index & Smoke Developed Index
Entry: 213 Insulation Flame Spread: Not to exceed 25
Total: 2118 Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
42'-8"
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 2118 s.f.
Building Code
6th Edition Florida Building Code: Residential
2014 National Electric Code NFPA 70
Scope of Work
New one level CBS single family
residence
Project Data
Project Name: Evan Miller
Street Address: T.B.D.
City: Ft. Pierce
County: St. Lucie
State: Florida
Design Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: N.A.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: H
Wind Exposure: C
Internal Pressure Coefficent:.18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
--
o
o
Carport
rV
I 9'-4" Ceiling
from F.F.E.
Porch
m
9'-4" Ceiling
i
o
from F.F.E.
,
N
i
Temp. Glass
Enclosure
M
f
t
1 rlp ,
I
Optional
abinets
H32 s.h.
Air r
o0 0
Safety
Glass
M
z' in + 11
7LT
11:1
I M w
e
-
Bdrm.3
Us
z
°
�AAA ---- ---- �
N
9'-4n Ceiling
25 s.h.
c
N
c
Egress
0 4
i10r
r" v,
lo�?
5068
,
TY-4"
8,11
4
'_2'
,
On 2r_1n 1�_ �_On
ll
jl 12'_3n
8'-4'
8u
`.
i
p i ei n� }
Dinin
5068
io
(;� 9'-4" eil' g
0 c
4" Ceil'
o
i�
Y
Y
[
N
(V
o
i F_6"
I
it
o
M
'
M
n
-
-
O
6
Z
I
CV
H32 s.h.
tti M
ti n
'jV`
1
Safety
Glass
4068
17- "
'4"
2'-6"
5'-10"
8"
1Z1,
ko
Master
Bdrm.
Great
Room
k o
9'-4" Ceiling
9'-4" Ceiling
B drm. 2
9'4" Ceiling
25 s.h.
25
25 s.h.
Egress LIEEnt
�
s.h.
Egress
,
c
c
I
9'-4" Ceiling
I____________
____________ ET ____________
from F.F.E.
____________ TT ____________
____________ TT --------------------------
Floor Plan
scale: 1/4" =1'-0"
TLCI- d!Si§l,
a�'Ycyr (C tcs:V'C ,
V4aw- _ rcrK Xtl
C�4e t'81c��5 r
0
w
�
F.
�
�
w
a0
O
03
w
W
�4
drawn
S.I.
checked
S.I.
date
1/30/19
scale
as noted
job number
18078
sheet
A-1
I
-----�
r I
3/12 1
— — — — — — — — — — — — ,
I I
I I
----------------�
------�
I I F- I
6/12 I
I I
I I
I I
I I
I I
I I
I I
6/12
I I
I I
I I
I I
I I
I I
I 1
I I
------------------�
I 3/12
I I
L---------------------------- J
Roof Plan
scale: 1/8" = F-0"
R20 Spray
Foam Insul.
9'-4"�-- T.O_B_ - — -
5/8" d.w
l x 4 p:1.
Firestop
Two Course Perimeter
Beam with (1) #5 Rebar
in each course, Filled
with Grout
1 x 2 p.t.furring
"
strips 24 O.C. —�
with R4.1 Foil
insulation
1/2"
#5 vert. rebar to
grout filled cell
See Floor Plan
for Locations
4" 30004 Fibermix Cone.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill --\
F.F.E.
(2) #5
Rebar
9.
5V Crimp (26 ga.) roofing
panels over Peel & Stick on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
Others
See Connector
Schedule
/ 12 2 x 4 p..t. 2 x 4 24"o.c.
Q 6� Cont.
Galv. Drip Edge
over 1 x 4 p.t.
2 x 8 Cedar
Fascia Board
Stucco Soffit Over
High Ribbed Wire
Lath
Install one layer of 15#
felt to framing prior to
installing wire lath
8x1.6x8
/- CMU Typ.
Hardie Plank Siding
fastened to CBS block
as per Product Approval
#5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
Stucco Stop
a I Grade
O
Typal Wall Section
Area Tabulation Climatic & Geographic Design Criteria
Living: 1426 Weathering: Negligible Termite Area: Very Heavy
Carport: 272
Porch: 207 Flame Spread Index & Smoke Developed Index
Entry: 213 Insulation Flame Spread: Not to exceed 25
Total: 2118 Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
n i l-R"
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 2118 s.f.
Building Code
6th Edition Florida Building Code: Residential
2014 National Electric Code NFPA 70
Scope of Work
New one level CBS single family
residence
Project Data
Project Name: Evan Miller
Street Address: T.B.D.
City: Ft. Pierce
County: St. Lucie
State: Florida
Design Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: N.A.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: II
Wind Expc)sure: C
Internal Pressure Coefficent:.18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
----------------------- ------------------------
Carport
---- -----------------------
v
I
9'-4" Ceiling
LJ ----
------
------
-
I from F.F.E.
I
I
I
Porch
1
9'-4" Ceiling I
o
from F.F.E.
I
O
I
I
I
O
Temp. Glass
I
Enclosure
ih
l668
0
— — — �„
Optional
I
Air Handler I
Cabinets
I
O0
0
H32 s.h.
Safe
Glass
r
in Attic
I
i
^ w
_ _ _
Bdrm. 3
00
------- -----
L1181
9'-4" Ceiling
25s.h.
o
voEgress
NFanny
0
_
a
0 4
_
5068
r.
8"
4'-8"
3'-2'
I
2" 0" 2'-1" F-6" 3'-0"
12'-3„
3'-4" 8'-4'
8"
¢o Kitchen
Dining
5068
0
1 9' 4" Ceil' g o
9 _4" Ceiling
o
o
(I� Q
FloN
I
EJ
o
o
I
I
I
_
7
r
M
9,-4a
b
66�
Z
Cing.
a
M
H32 s.h.
M
1w�D n
' I
Safety
�J
Glass
�Cb
� o
N N
o
4068
8"
1P_8"
17-4"
3'-4" T-6"
5'-10"
8"
0
o
'^
Master
Bdrm.
Great
v
Room
o
9'-4" Ceiling
9'-4" Ceiling
Bdrm. 2
9'-4" Ceiling
TF-
Egress
LID
T
Ent
E
25
s.h.
25 s.h.
Egress
Q
I
9'-4" Ceiling
I
�,
I
I____________
____________ ____________
TT
from F.F.E.
______________ __________
____________ ____________
____________I
Floor Plan
scale: 1/4" = 1'-0"
N
uu�
I�
E�
N
A••I
z
Q
M
0
F
a
w
z
•�
U
w
o
ai
• •--I
r�
>
v
U
C7
N
•'"i
z
o
Q
�
N
o
N
�
�
FDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supersedes All Previous Site Plans for
OSTDS - - Q t & WAI get-2,9W
drawn
S.I.
checked
s.l.
date
1/30/19
scale
as noted
job number
18078
sheet
A-1