Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEProject Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1553 Certification for Design Load Compliance DAVIS Project Address: 137 DOMINION CT, FT PIERCE, FL 34949 JUN 2 7 2019 ST. Lucie County, Permitm 1905-0709 Occupancy Type: Constructions Type:,I�, INSTRUCTIONS FOR USE: REVIEWED FOR • This certification must be completed, signed, and sealed by the design professi(i OMCOMPI.I64NCE • Submit (2) copies for residential, (3) copies for commercial with all permit applic iryro.Ivinikt 6 NTy o New Residences (single or multi -family) 6B��1t��5S��EE o Residential. Addition BODD o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the N above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as'(check one): _Enclosed _Partially Enclosed —X-Open 3. Risk Category: I X II _III IV Exposure Category:_B C X D 4. Design Wind Velocity 165 mphASD X LRFD End Zone Width: 1' ft 5. Mean Roof Height 5'+/- DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based an 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zane 2: Zone 3: Zone 4:+60.6/-64.1 Zone 5:+70.1/-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure?%Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie strr�. County. I also c r •ffiVrtat' Anpral elements depicted on these plans provide adequate resistance to the design forces soecifis&X.0%S9a-6i'•. _ w • •O�„ sell , Signature,B4 • Sear' Revised 12/07/2018 DANIEL PAUL RETHERFORD 72451 Print Name Cert # & Co. Cart Auth. 1402 HARTMAN ROAD, FORT PIERCE, FL 34947 Company Name & Address