Loading...
HomeMy WebLinkAboutGENERATOR PAPERWORK9/11 _kW _ GENERAC® MAY S 0 2019 GUARDIAN° SERIES -- &. Lucie County, mitti Pen"sidential Standby -Generators-- Air -Cooled Gas Engine INCLUDES: '/ALp� • True Power- Electrical Technology �®t}.e+Q9 Standby Power Rating Models G0Q070�9-1, G007030-1 (Aluminum - Bisque) - 9 kW 60 Hz • Two Line LCD Multilingual Digital Models G007032-1, G007033-1 (Aluminum - Bisque) -11 kW 60 Hz Evolution" Controller (English/Spanish/ French/Portuguese) Model G007031-1(Aluminum - Bisque) 11 kW 60 Hz • Two Transfer Switch Options Available: / 100 Amp 16 Circuit Switch or 200 Amp Service Rated Switch. See Page 5 for Details. ST.LUCIE COUNTY J _ PLAN REVIEW _ • Standard Wi-Fle Remote Monitoring q • Electronic Governor BLDG: • System Status & Maintenance Interval LED IndicatDOTE • Sound Attenuated Enclosure ELEQ'✓_ � • Flexible Fuel Line Connector DATE • Direct -To -Dirt Composite Mounting Pad PLUMB: DATE: • Natural Gas or LP Gas Operation MECH., • 5 Year Limited Warranty DATE: • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18' (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hl!llppss Nassers.swn.orgllrDrwyiDirectoryOlLisWPMductslConstructiminduslry/ 9Y3_D.0 204_l3204-01-01Reva.Pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of Mended run times in high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave farm produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: V PROTOTYPE TESTED V NEMA MG-22 EVALUATION J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY GENERAC' c(glus QUIETI VI - Note: CUL certification only applies to unbundled units and units paclaged with limited circuit switches. Units packaged with the Smart Switch are UL candied in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state -of -Heart power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at �l %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O MOBILE LINK" REMOTE MONITORING: FREE with every Guardian Series Home standby gene Allows you monitor the status of your generator from in thehe worlda d using a smartphone, tablet, or PC. Easily access ConnectPR0MISE'�.•. = GENERAC Q®;P,anywhere information, such as the current operating status and maintenance alerts. F �,•*� your account to your authorized service dealer for fast, friendly and proactive service. With Mobile Link, you are taken care of before the next power outage. �• GENERAC 1/11 kW features and benefits ngine • GeneracG-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine - - - - - - - - -run cooler reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls • Electronic ignition/spark advance • Full pressure lubrication system • Low oil pressure shutdown system • High temperature shutdown Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unitthat operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage totl % prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, al -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences, • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80%pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five (5) seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for five (5) minutes every other week Also offers a selectable setting for weekly or monthly cperation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending an outdoor air temperature. Compatible with lead acid and AGM -style batteries. . • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Litt -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 181 away from a building. 9/11 kW GENERAC® features and benefits Installation System • 1 If (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct-lo-di cr�osite mounting pad- - Complex lattice design prevents settling- or sinking of the generator system: -- - -- - - — - - - -- • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Remote Monitoring • Ability to view generator status Monitor your generator via your smadphone,tablet, or computer at anytime via the Mobile Linkapplication for complete peace of mind • Ability to view generator Exercise/Run Review the generators complete protection profile for exercise hours and total hours and Total Hours • Abilityto view generator maintenance Provides maintenance information for your specific model generator when scheduled maintenance is due information • Monthly report with previous month's Detailed monthly reports provide historical generator information activity. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery • Weather information Provides detailed local ambient weather conditions for generator location GENERAC 9/11 kW , specifications Generator -% Model GOD7029-1, G007030-1(9 kW) G007031-1, G007032-1, G007033.1(11 Irm pared Maximum Continuous Power Capacity(LP) .___ ___ __ 9,000 Waits" - 11,000Waas'__� Rated Maximum Continuous Power Capacity (NG) Q000 Watts' 10,000 Watts' ,Rated Voltage _, -. _ 240 _ 240 Rated Maximum Continuous Load current-- 240 Volts (LPMG) 37.5/33.3 45.8/41.7 �eYotal Harmonic Distortion — -_ - ___ __ Less than 5% Less than 5%—_] _ Main Line Circuit Breaker 40 Amp 50 Amp Number of Rotor Poles 2 z (_Oted AC riequency 60 H2 60 H� Power Factor 1.0 1.0 Sound output in d8(A) at 23 it (7 m) with generator operating at normal load" 63 tie [Soun—do t inn d3(A) at 23 ff (71 with geerator In Dufei--TeaC' low-s'paaH exercise mode" 54 58 Number 112 Load 90 (2.55) 107 (3.03) Full Load 120 (3.40) 159 (4.50) Liquid Propane f137hr (gaVhr) [I/hr] 1/2 Load 32 (0.87) [3.29] 44 (1.22) [4.62] Full Load 50 (1.37) [5.20] 72 (1.97) [7.45] Controls ICommon Fate'mel Fault CapaSilityT _ Sla'nda�d ] Field Upgradable Firmware _ Standard '-Sued leeekare taken from he lent of de genaator. Sound leldstA nham orervtlesmNe gecealor may be higher depereing on ine66ation pardmeta5. Rating definitions-S^cegby Apptitadeforsupptymg emergency paev rude du26on of meutililypoxeroubge.No mfkad mpabillly isMOMefordnsating. (All ratings in acoeftce with BS5514. IS03045 and DIN6271). • Memmm� Filmodampsand amemare sutjetlroand limilnd M such Iddorsazhrel BtiJme�lwle cententambierdkmpeabnc, MUInde, engine pm am ceMitian, etc Mamnum power de xearesabou13.5 gune !bream 1,000feet(3D4.8 mesxs)abossealeael; and alsowl) de=re aboutt pawdloreadl6°C(10 Tj above 16'C(60.9. GENERAC 9/11 kW Limited Circuits Switch Features • 16 circuits, breakers not included. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time, • Dual Coil Design. • Main contacts are silver plated or silver alloy to resist welding andsiicking. • NEMA/UL 3R aluminum outdoor enclosure. Multi listed for use with 1"standard, tandem, GFCI and AFCI breakers from • Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Dimensions Height Width Depth 111 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Service Rated Smart Switch Features available on 11 kW model only • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure. Dimensions 20OAmps 120240, 1e Open Transition Service Rated Height Width Depth HI H2 Wl W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 ons Model G007030-1(9kMU —G007032-1(11kW) No. of Pales 2 2 Current Rating (Amps). Voltage Rating (VAC) 100 120/240.10 100 120/240, 16 UtilityVoltage Monitor (Fixed)* -pickup -Dropout 80% 65% 80% 65% Return to utility* approx 15 sec approx 15 see Exercises bi-weekly for 5 minules't Standard Standard UL Listed Standard Standard Total Circuits Available 16 16 Tandem Breaker Capabilities Braden 81randems Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 10.000 *Function of Evolution Controller t Can be set to weekly or monthly Model G007033-1 (11kM No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 1201240,10 UtilityVoltage Monitor (Feed)' -pickup -Dropout 80% 65% Return to Utility* approi 13 sec Exercises bl- lay for 5 minutes*t Standard UL listed Standard Enclosure Type NEMA41L3R Circuit Breaker Protected 22,000 Lug Range 250 MGM-#6 *Function of Evolution Controller t Can be set to weekly or monthly 3/11 kW GENERAC' available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. G007005-0 _ Wi-Fi LP Fuel Level Monitor Monitoring the LP tanks fuel level is an Importantstepin making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact®). The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. G007101-0 Battery Pad Warmer (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly falls below 0°F. The breather wanner is for use in extreme cold weather applications. For use with Evolution controllers only G007103-1 BrealherWarmer in climates where heavy icing occurs. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621-0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, G007027-0 Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006482-0 - 9 kW Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine G00648M -11 kW cheduleMaintenance Scheduled Mice Kit maintenance on a Generac automatic standby generator. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its r7771 Smart Management Module power management capabilities. it provides additional power management flexibility not found in any other (50 Amps) power management system. dimensions & UPCs Dlmenslons shmm are approdmete. Refer to Installatian mould Ideaddimemlom DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. IFF .EVIEW GENERAC° Model UPC G007029-1 696471074109 G007030-1 696471074116 G007031-1 696471074123 G007032-1 696471074130 G007033-1 696471074147 Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02018 Generac Pa Systems, Inc. As dAMs r ftflecL AD spe mIlons are sublsgto dWpewlhod norm. Pan No. 1ODDDD00191-G Ba30/18