Loading...
HomeMy WebLinkAboutPROJUCT SUMMARYPro ect Summa Job: 160 SE Celesta Court ry SCANNED Data: Jan 24, 2020 WebREPS Entire House BY ST. Craig C Brooks 1-800•810-3280 WebREPS, LLC Plan: 160 SE Celesta Court. St. Lucie County 188082nd Nenue Suite #203, Vero Beach, FL 32966 Phone: 800-810J280 Fax:888-971-2999 Email: manual]@ ebrepsusa.00m- License:C4C054709 For. Jamie McNair, McNair Empire LLC 5359 NW South Lovett Circle, Port St Lucie, FL 34986 � L.NLiVC L� Phone: 772-446-2155 Email: jamiemcnair@icloud.com Notes: 160 SE Celesta Court, PortSt Lucie, FL 34986 W 8 2020 ST. Lude County, Permitting. D» • • • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13727 Btuh Structure 16280 Btuh Ducts 5475 Btuh Ducts 7815 Btuh Central vent (82 cfm) 2525 Btuh Central vent (82 cfm) 1353 Btuh Outside air Outside air Humidification 3500 Btuh Blower 1707 Btuh Piping 0 Btuh Equipmentload 25227 Btuh Use manufacturer's data y Rate/swingg multiplier Equipmentload 1.00 27154 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5450 Btuh Ducts 2125 Btuh Central vent (82 cfm) 3428 Btuh Heating cool[ nngg Outsideair Area (its 1485 1485 Equipment latent load 11003 Btuh Volume (ft3) 11883 11883 Airchangeslhour 0.45 0.23 Equipment Total Load(Sen+Lat) 38157 Btuh Equiv.AVF (cfm) 89 46 Req. total capacity at0.71 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX140421 K* AHRI ref Coil AS48A4Z4G++V AHRI ref 201225964 Efficiency 60AFUE Efficiency 12.2 EER,14 SEER Heating input 0 Btuh Sensible cooling 27335 Btuh Heating output 0 Btuh Latent000ling 11165 Btuh Temperature rise 0 OF Total cooling 38500 Btuh Actual airflow 1283 cfm Actual airflow 1283 cfrn Airflowfaclor 0.067 cfm/Btuh Airflowfactor 0.038 cfin/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.71 Le Calculations approved byACCA to meet all requirements of Manual J St � �0p t 4t wriq!?LIt R` 2020-Jan-2412:57:47 ^-k- ....» .» Poght-Suite®Unirersa1201919.0.15 RSU16998 Page 1 ACCA.AACWlmairErnpire, LLM160 BE Celesta Courtmp CaIC=MJ8 Front Doorlaces:S ii Level 1 R E CETV E D BEDOOM 4 i LST. JAti 2 8 2020 166 cfm Lucie County, perrnitting v cLa BATH4 VEST � 61 ofm LAUNDRY 42 cfrn BEDROOM 1 CK217 cfm CRk 43 cfrn I O�44cfm BATH 1 BATH 2 1 AHU 187 cfmjI BEDROOM 2 BEDROOM 3 II CL2 CL3 ° CHk 127 cfm 148 cfm KITCHEN 'Eq 82chn GREAT ROOM 'Ek82 cfrn 0�k 146 cfm OFFICE ® 94 cfM Job #: 160 SE Celesta Court WebREPS, LLC Scale: 1 :101 Perfoffned by Craig C Brooks for. Page 1 Jamie McNair 1880 82ndAvenue Suite # 203 RightSude® Universal 2019 5359 NVJ South Lovett Circle Vero Beach, FL 32966 19.0.15 RSU16998 Port St. Lucie, FL 34986 Phone: 800.810-3280 Fax: 8BB-971-2999 2020Jan-24 13:00:59 Phone: 772-446-2155 manualj@webrepsusa.com ...re, LLQ160 BE Celesta Court.rup jamiemmair@icloud.com