FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MARGARET JONES
Builder Name:
SUANNED
Street: 3410 SLOAN RD.
Permit Office: ST. LUCIE COUNTY
BY
City, State, Zip: Fr. PIERCE, FL,
Permit Number.
St. Lucie Countv
Owner: MARGARET JONES
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types(1056.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1056.00 ft'
b. N/A
R= ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedroom�Bedrms In Addition) 3(3)
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (951.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 951.00 ft
6. Conditioned floor area above grade (ft2) 948
b. WA
R= ft'
Conditioned floor area below grade Ift) 0
c. WA
R= ft'
11. Duds
R ft'
7. Windows(126.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/C
6 125
a. U-Factor: Sgl, U=0.79 126.00 ft'
SHGC: SHGC=0.48
b. U-Factor. N/A ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
28.0 SEER:15.10
c. U-Factor N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.480
14. Hot water systems - None required
8. Floor Types (948.0 sqft.) Insulation Area
a.
Cap: N/A
a. Slab -On -Grade Edge Insulation R=0.0 948.00 ft'
b. Conservation features
EF: 0.000
b. N/A R= ft'
c. WA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.133 Total Proposed Modified Loads: 36.48
PASS
Total Baseline Loads: 37.87
1 hereby certify that the plans and specifications covered by
Review of the plans and
STgl�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�THE
�} , _ ; O
Code.
calculation indicates compliance
yt ir,I ryOj ' '
with the Florida Energy Code.
1; nr,,�'Y4v, :;;;€-•`;a'=„�O
PREPA Y
Before construction is completed
r
a
DATE:
this building will be inspected for
compliance with Section 553.908
��
t7 y
°
I hereby certify that IN bull ing, as desig d, is in compliance
Florida Statutes.
with the Florida Ener y Co
COp WE tip
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
5/28/2019 8:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPi:-..
SUMMARY CHECKLIST REPOR'
PROJECT
Title: MARGARETJONES
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 948
Lot #
Owner Name: MARGARET JONES
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
3410 SLOAN RD.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: Addition
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 948 7584
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 1 276
2208 No 2
1
1 Yes
Yes
Yes
2 BEDROOM 3 120
960 No 1
1
1 Yes
Yes
Yes
3 BEDROOM 2 96
768 No 1
1
1 Yes
Yes
Yes
4 BATH 35
280 No 0
1 No
Yes
Yes
5 Room5 45
360 No 0
1 No
Yes
Yes
6 A/C 15
120 No 0
1 No
Yes
Yes
7 LIVING/KITCHEN 361
2888 Yes 2
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 1 50 ft 0
276 ft'
_-
0 1
0
2 Slab -On -Grade Edge Insulatio
BEDROOM 3 22 ft 0
120 ft'
_
0 1
0
3 Slab -On -Grade Edge Insulatio
BEDROOM 2 18 ft 0
96 ft'
__
0 1
0
4 Slab -On -Grade Edge Insulatio
BATH 1 ft 0
35 ft'
-_
0 1
0
5 Slab -On -Grade Edge Insulatio
Room5 1 ft 0
45 ft'
—
0 1
0
6 Slab -On -Grade Edge Insulatio
A/C 1 ft 0
15 ft'
___
0 1
0
7SIab-On-Grade Edge Insulatio LIVING/KITCHEN 42 ft 0
361 ft'
_-
0 1
0
5/28/2019 8:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INP SUMMARY CHECKLIST REPOR'
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 999 ft'
0 ft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
160
948 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Free Truss Type
1
Under Attic (Vented) BEDROOM 1
30
Blown
279 ft-
0.1
Wood
2
Under Attic (Vented) BEDROOM 3
30
Blown
120 ft'
0.1
Wood
3
Under Attic (Vented) BEDROOM 2
30
Blown
96 ft'
0.1
Wood
4
Under Attic (Vented) BATH
30
Blown
35 ft-
0.1
Wood
5
Under Attic (Vented) Room5
30
Blown
45 W
0.1
Wood
6
Under Attic (Vented) A/C
30
Blown
15 ft-
0.1
Wood
7
Under Attic (Vented) LIVING/KITCHEN 30
Blown
361 ft-
0.1
Wood
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar
Below
1
N
Exterior Concrete Block - Ext InfiEDROOM 1
4.1 1
0 8
0
8.0 ft'
0
0 0.4
0
2
E
Exterior Concrete Block - Ext IndiEDROOM 1
4.1 13
0 8
0
104.0 ft-
0
0 0.4
0
3
S
Exterior Concrete Block - Ext IndIEDROOM 1
4.1 23
0 8
0
184.0 ft-
0
0 0.4
0
4
W
Exterior Concrete Block - Ext IndiIEDROOM 1
4.1 13
0 8
0
104.0 ft'
0
0 0.4
0
5
N
Exterior Concrete Block - Ext IndiffDROOM 3
4.1 10
0 8
0
80.0 ft'
0
0 0.4
0
6
E
Exterior Concrete Block - Ext IndilEDROOM 3
4.1 12
0 8
0
96.0 fN
0
0 0.4
0
7
E
Exterior Concrete Block - Ext InfilEDROOM 2
4.1 12
0 8
0
96.0 ft'
0
0 0.4
0
8
S
Exterior Concrete Block - Ext InREDROOM 2
4.1 6
0 8
0
48.0 ft'
0
0 0.4
0
9
N
Exterior Concrete Block - Ext InddVING/KITC
4.1 18
0 8
0
144.0 ft'
0
0 0.4
0
10
W
Exterior Concrete Block - Ext InddIJING/KITC
4.1 24
0 8
0
192.0 ft'
0
0 0.4
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
_ /
Wall
Overhang
V
#
Omt ID Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade Screening
1
S 3 Metal Single (Clear) Yes
0.79 0.48
N
24.0 ft'
2 ft 0 in
1 ft4 in
None
None
2
W 4 Metal Single (Clear) Yes
0.79 0.48
N
15.0 ft'
2 ft 0 in
1 ft 4 in
None
None
3
N 5 Metal Single (Clear) Yes
0.79 0.48
N
12.0 ft'
2 ft 0 in
1 ft4 in
None
None
4
E 6 Metal Single (Clear) Yes
0.79 0.48
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
E 7 Metal Single (Clear) Yes
0.79 0.48
N
12.0 ft'
2 ft 0 in
1 ft 4 in
None
None
6
N 9 Metal Single (Clear) Yes
0.79 0.48
N
12.0 ft'
2 ft 0 in
1 ft 4 in
None
None
7
W 10 Metal Single (Clear) Yes
0.79 0.48
N
9.0 ft'
2 ft 0 in
1 ft 4 in
None
None
8
W 10 Metal Single (Clear) Yes
0.79 0.48
N
30.0 ft'
2 ft 0 in
1 ft 4 in
None
None
5/28/2019 8:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INP • ..'SUMMARY CHECKLIST REPOR
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000254
632 34.7 65.25
.0881
5
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Duds
1 Electric Strip HeatlSupplemen None
COPA
17 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/Supplemental for
Split
SEER: 15.1 28 kBtu/hr cfm
0.85
1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area
Volume
FEF
ft'
DUCTS
J — Supply —
— Return —
Air CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler TOT
OUT QN RLF
Heat Cool
1 Attic 6 125 ft'
Attic
65 ft' Default Leakage
A/C (Default)
(Default)
1 1
TEMPERATURES
Programablee(,]Thermostat: Y
Ceiling Fans:Cooling
Feb
[[[[XX
Venting Feb Mar
f
Apr
Mayr[[ ]]
Jun Jul
�X [[ ]]
[ Aug [X] Sep
[ j [[X]]
LJ
Dec
(Jan
[ ]Jan X�
Mov
ay lxl Jun [ Jul
LKl
[ Aug [( ]I Sep
lxl Occtt [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7 8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78 78
80
80
80
80
PM 80
80 78
78 78 78
78 78
78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78 78
78
78
78
78
PM 78
78 78
78 78 78
78 78
78
78
78
78
Heating (WD) AM 66
66 66
66 66 68
68 68
68
68
68
68
PM 68
68 68
68 68 68
68 68
68
68
66
66
Heating (WEH) AM 66
66 66
66 66 68
68 68
68
68
68
68
PM 68
68 68
68 68 68
68 68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM 1
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft'
It
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
Room5
Default(8 lbs/sq.ft.
ft'
ft
0.3
A/C
Default(8 Ibs/s .ft.
ft'
It
0.3
LIVINGIKITCHEN
5/28/2019 8:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 -AIR BARRIER AND INSL^=__rION INSPECTION COMPONENT t _", ERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MARGARET JONES Builder Name:
Street: 3410 SLOAN RD. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner. MARGARET JONES Jurisdiction:
_
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
-
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light factures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Dinino and wirino
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/28/2019 8:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Addition
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
A/C
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
28.0
a) Split system SEER
15.1
5. Is this a worst rase? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
948
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.790
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.480
14. Heating system: Capacity
17.0
c) Area
7c.
126.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
1 la.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be i stalled (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be compl9t�ld ased on installegWode compliant features.
Builder Signature: /(it/�� Date: 0�T
Address of New Home/ 3410 SLOAN RD. City/FL Zip: FT. PIERCE. FL
5/28/2019 8:05:28 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
+ wrightsofte
r�
Project Summary
Enbre House
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Kam 772-466-6799 Email: OUICKCALCS@A0LC0M
Project• •
For. MARGARET JONES
3410 SLOAN RD., FT. PIERCE, FL34947
Notes:
Job:
Data:
By.
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42
OF
Outside db
90
OF
Inside db
70
OF
Inside db
75
OF
Design TD
28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure
15737
Btuh
Structure
18234
Btuh
Duds
3056
Btuh
Ducts
4234
Btuh
Central vent (0 cfin)
0
Btuh
Central vent (0 c1m)
0
Btuh
(none)
(none)
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
18793
Btuh
Use manufacturers data
n
Rate/swingg multipplier
Equipmenisensibleload
0.95
21345
Btuh
Infiltration
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2599
Btuh
Ducts
1205
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Cool'
(none)
Area (ft�
971
971
Equipment latent load
3805
Btuh
Wlume
8739
8739
Airchangeslhour
OA5
0.23
Equipment Total Load (Sen+Lat)
25150
Btuh
Equiv. AVF (cBT1)
66
33
Req. total capacity at 0.70 SHR
2.5
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Lennox
Trade
Trade LENNOX
Model
Cond 14ACX-030-230A**
AHRI ref
Coil CBA25UHV-030-23V*
AHRI ref 202540515
Efficiency
100 EFF
Efficiency 12.5 EER,15.1
SEER
Heatinglnput
5.0
WV
Sensible000ling
19600
Btuh
Heating output
17156
Btuh
Latent000ling
8400
Btuh
Temperature rise
50
OF
Total cooling
28000
Btuh
Actual airflow
312
dm
Actual airflow
933
cfin
Airflowfactor
0.017
cfmBtuh
Airflowfactor
0.042
cfmBtuh
Static pressure
0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.86
Calculations approved byACCAto meet all requirements of Manual J Sth Ed.
wrights ft- 2019-May-2808..05554
���..� •..,.., Ri9M-Stile®Uriversa1201919.0.07 RSW8101 Page I
...KMDcaa TMWdghmftHVACUONES,MARGARETnp Calc=MI8 Fmit Dwrfaces: S
I wrightsoftRight-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. sr
317ST, LUCIE LANE, FORTPIERCE,FL34946 Ptcm:772-466-6799 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
ftmedwell
Room height
Room dimensions
Room area
FsBre House
1320 ft
9.0 ft
971.0 W
BEDROOM
50.0 It
9.0 It heaVcool
13.0 x 23.0 ft
299.0 W
Ty
Consbucdm
number
U-Ndue
(BUTAIft `F)
Or
HTM
(BtuK"
Area (fe)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter (fl)
Load
(Bluh)
Heat
I Cod
Gross
NOS
Heat
Cod
Gross
N/PIS
Heat
Cod
6
11
-ll44!!
_G
— —949
—M
1237
853
—949
1553
1117
320
1600
519
13A-
1Ac1am
0.143
_1270
n
_n_,
a
_e_
s
_s_
w
w
w
4.00
._.35.56
4.00
35.56
4.00
_35.56
4.00
35.56
35.56
219
—34.77
219
85.05
_219
.a34.77.
219
84.36
87.06
_,2.45
0.00
251
__24
333
24
_ 261
—24
333
9
45
_97.1,
237
___0
309
2
9
9
36
0
20
LQ!
�--G
�—<
13A4=
1AKl=
13A�
1Ac10n
0.143
1270
0.143
_835
676
2065
^ 519
_835
610
759
3918
_2379
0
—0
117
_0
207
�24
117
0
15
=298
299
—0
117
0
783
24
102
0
1
468
_ 0
733
_853
40B
0
533
.,_ 410
1385
—A
256
_ o
400
835
223
0
1306
�,733
0
237
�24,
279
1
3
4pJ
L�—GG
.C_
F
13A =
1A-dom
1A-dom
168.19atl
22LW
�1270
0.143
1270
1270
�0.049
0.969
—
�
=
�
�1_.32
2T69
�07.1.
132
=1392
3655
_299
50
971
_—_
61
c)AED e>mzdm
1188
241
Envelopelossrgain
13720
14302
4827
4014
12
a) Mltaton
b) Roon %,erNlatim
2017
0
552
0
764
0
209
0
13
fnleMal gaits Oovpanl5@ 230
Appliarlomofller
6
1380
2DO01
2
I
460
1 0
Subbtal Qines6b 13)
15737
18234
5591
4683
14
15
Lesse&rral load
Lessfransfer
Redisbibuton
Subbtzl
Ductloads
19%
23%
0
0
0
15737
3056
0
0
0
18234
4234
190/0
23%
0
0
13
5605
1088
0
0
23
4705
1093
Total room load
Airrequired(cim)
18793
312
22468
933
6693
111
5798
241
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
=RQN . t- 2019-May-280895:54
AC& -^ Rigtt-Shce®Udversa1201919.0.07 RSU08101 Pagel
...KOoa rts\WdgtboftWACUONES,MARGARETnp Calc=MIB Frort Doorfaces: S
wrightsoft• Right-J® Worksheet
Entire House
QUICK CALCS, INC.
317 ST.. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS AOL.COM
Job:
Date:
By:
1
2
3
4
5
Room name
Eposedwall
Rcom height
Rcom dimensions
Raamarea
BEDROOM3
22.0 ft
9.0 ft head000l
12.0 x 10.0 ft
120.0 ft
BEDROOM2
18.0 a
9.0 ft heaftd
120 x 8.0 ft
95.0 ft'
Ty
Construmon
number
U-value
(Bluhfti'q
Or
HTM
(Bfuhln
Area (fF)
or penmeler (ft)
Load
AM)
Area (fe)
or perimeter (ft)
Load
(Btah)
Heat
I Cad
Gross
N/PIS
Heat
Cool
Gross
N/P/S
Heat
Cod
6
11
11qqJJ -.
13A-0o6
JA-dom—
0.143
.,..a_1270
n
_.n_
a
a
n
vs_
w
w
w
=;
-
4.00
-35.56
4.00
3556
4.00
35.56
4.00
35.56
35.56
= 37
27.69
219
_34.77.
219
86.05
219
—34.77
219
84.36
87.06
,e 245
0.00
90
______12
108
12
—78
312
427.
171
417
0
0—
0
0
--0
lqJ
.
U�J�
`C
13A-4=
1Aclom
13X4&i
JA-c1bm
13A4=
1Ac1om
1Ac1om
J6&19ad
22A-fpl
o.143
1270
0.143
1270
�0.16
1270
1270
=6049
0.969
—0.
96
1.
384
427
210
1033
—0
108
12
—0
96
1
384
427
—0
210
1033
—118
--0
—0
0
0
0
V120
120
0
_.-0
0
0
�_0
,_,—.,.,120
22
— 6
0
' 0'
54
0
- 54
—0-0
0
0
______0
- 96
216
l/tJ
LI—(C`
=
—0
0
0
0
,®®_165
0
0
0
'=294
0
0
,0
— 96
0
0
0
___eJ32
498
—0
0
0
v_.,___..0
�..�235
0
_
;C�
F
609
0
96
18
6
c)AED exarson
-142
52
Ernelope loss/gain
2324
1982
1657
1544
12
a) Infiltration
b) Room ventilation
336
0
92
0
275
0
75
0
13
Inlernalgains O—Pants@ 230
Appliancestother
1
230
0
1
1
230
1 0
Subtotal (lines6 t313)
2660
2304
1933
1849
14
15
Lesse#enralload
Lesstrarrsrer
Redistribution
SubDobl
Dudloads
190/0
23-
0
0
0
2560
517
0
0
0
2304
535
19%
23%
0
0
0
1933
375
0
0
0
1849
429
Total room load
Airregdred(dm)
3177
53
2839
118
2308
38
2279
95
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-PW wrighiso�f^[- 2019-May-2808:05:54
A%k •-^ - Rig"Ute®Uriversal 201919.0.07 RSU08101 Paget
.K\Dume ..orts\WdgltsoftHVACUONES,MARGARETnp Calc=Ml8 FrontDoorfaces: S
+wrightsoftRight-J®Worksheet Job:
Entire House Date:
QUICK CALLS, INC, sy
317ST. LUCIE LANE, FORTPIERCE, FL34946 Plrm:772366-6799 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Roan rune
EVosedwall
Roan height
Room dimensions
Roan area
RATH
O ft
9.0 ft heaticod
7.0 x 5.0 It
35.0 fe
Room5
O ft
9.0 ft heaVood
9.0 x 5.0 ft
45.0 fe
Ty
Consbvcfion
number
U-value
(BWhdt *q
Or
HTM
(Bluh"
Area (W)
or perimeter (ft)
Load
(Btuh)
Area (fF)
or permeter (ft)
Load
(Btuh)
Heat
I Cod
Gross
NOS
Halt
Cool
Gross
NIPS
Heat
Cod
6
11
lrrl
13A-0ocs
JAc1Cm
0.143
,.-�1270
n
„_n_
a
_e
5
-s_
w
w
w
4.00
_35.56
4.00
_35.56
4.00
�35.56
4.00
35.56
35.56
219
-34.77
2.19
86.05
" 2.19
-34.7Z
Z19
84.36
87.06
0
,.__0
0
0
-6--6--0
-0.
0
0
0
0
--0
0
0
-0
0
0
0
0
0
0
0
0
0
0
'-0
�0
0
0
-"'--0
.-0
Y�J
I--G
_.-
44ppJJ
`C
13AAo s
1Ac1am
13A4as
1Ac1om-
0.143
1270
0:143
. - 270
0.143
1270
1270
___-__0
0
0
0
0
0
-0-0-0-0
0
0
�'�0
_0
0
0
Y'-0
�0.
0
0
��0
13AAors
1Ac1om
1Aytom
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
IF
F
18&'19ad
22A�1p1
�0.989
0.989
-
,� 7.69
27.69
_. 0.00
0.00
35
35
30
0
,a,�_40
0
, 80
=45
___-_,,. 45
�, --6 .
�_..,�62
„_110
0
45
0
8
C)AED exalraorl
-5
-6
Envelope lossgain
48
81
62
104
12
a) Infiltration
b) Room wifilaim
0
0
0
Ol
0
1 0
0
0
13
InMmd gains Oavparhss@ 230
Appliarxeslotw
0
0
0
0
0
0
Subtdal(lines(S b 13)
48
81
62
104
14
15
Lesse)lemal load
Lesstransfer
Redisdbutm
Submlal
Ductloads
19%
23%
0
0
19
67
13
0
0
32
112
28
190/0
23%
0
0
-62
0
0
0
0
-104
0
0
Tolal mom load
Airrequired (dm)
80
1
138
6
0
0
0
0
_ Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrYgtitsof t- 2019-May-2808:05:54
A&k - RigfFSUteOUriv =1201919.0.07RSW8101 Page
_H�MrtslWdgtLroftWACUONES,MARGARET.np CaIc=MI8 Frorl Doorfaces' S
t '
wrightsoft• Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. sy
317ST. LUCIE LANE, FORTPIERCE, FL34946 PPore:772-466-6799 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Roan name
EVOsedwall
Roan height
Room dimensions
Roxn area
P/C
0 ft
9.0 it he8V0]C9
3.0 x 5.0 It
15.0 IF
LMNGKITCHEN
420 ft
9.0 ft heaVoxi
1.0 x 361.0 It
361.0 IF
Ty
Conshdw
number
U-value
(BtuhTe-'F)
Or
HTM
(BLh*)
Area (IF)
x perimeter (ft)
Load
(Btuh)
Area (ft�
or perimeter Qt)
Load
(BUh)
Heat
Cad
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cool
6
11
13P.-'
JAcIom
—0.143
n
_n_
a
_s_
w
w
w
400
_,_35.56
4.00
_35.56
4.00
35.56
35.56
e_.
�1.37
27.69
2]8
_,_,34.77_
219
—34.77.
219
84.36
97.06
T_
,_2.45
0.00
0
0
0
�0
- 6
—0
0
0
0
— 162
12
150
_601
427
0
328
_ 417.
0
„-0
lQJ
`G
13A-40cs
13
_1Aciom
_1270
0.143
e12700
0.143
1270
1270
0
—0.
0
0
0
10
0
`0
0
0
—0
0
i
—
13A-0as
1Aclan
IAclOm
18&19ad ..._�Q989
22A-ml
0
0
0
_'16..
15
—0-0-0-0-0
0
0
0
0
0
0
216
9
30
177
1
21067
709
320
387
759
2612
C
F
0.989
-
0
0
=30
0
,� 361
361
`342
42
1163
1183
860
0
0
6
o)AEDeminzi n
-2
1155
Ernelope lossigain
21
35
4781
6543
12
a) Witation
b) Roomvenblalim
0
1 0
0
Ol
642
0
176
0
13
Internal gains O=pants@ 230
Applianoe.4ofher
0
0
0
2
460
20M
Subbtal(Ims6 to 13)
21
35
5423
9179
14
15
Lessa#emalload
Lesstransfer
Redistribution
Subtotal
Ductloads
19%
23%
0
0
-21
0
0
0
0
-35
0
0
19%
239/6
0
0
50
5473
1063
0
0
84
9263
2151
Total roan load
Airrequired(dm)
0
0
0
0
6536
109
11414
474
Calculations approved bVACCAto meet all requirements of Manual J 8th Ed.
wrlghiso_it- 2019-M%,2808:05:54
A& Rigt4Sdte&Udversal 201919.0.07 RSU08101 Page 4
...Krpoa its\WdgFfsoftHVACUONES,MARGARETnQ Calc=Ml8 FrortDoorfaces: S
l
Ducstem Summary Job:
�- wrightsoft t System rY oar:
Entire House By.
QUICK CALCS, INC.
317ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 7724688799 Email: QUICKCALCS@AOL.COM
For. MARGARETJONES
3410 SLOAN RD., FT. PIERCE, FL34947
Heating
Cooling
External static pressure
0.50
in H2O
0.50
in H2O
Pressure losses
0.28
in H2O
0.28
in H2O
Available static pressure
0.22
in H2O
0.22
in H2O
Supply/return available pressure
0.11010.110
in H2O
0.110/0.110
in H2O
Lowest friction rate
0.080
in/100ft
0.080
in/100ft
Actual airflow
312
cfrrl
933
clim
Total effective length (TEL)
81 ft
Name
Design
(Btuh)
Htg
(Cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
HxW
(in)
Dud
Mat
Actual
Ln (it)
Ftg.Egv
Ln (ft)
Trunk
BATH
c 138
1
6
0.080
4.0
Ox0
VIFx
5.0
70.0
BEDROOM 1
c 5798
111
241
0.080
8.0
OxO
VIFx
11 A
70.0
BEDROOM2
c 2279
38
95
0.080
6.0
Ox0
VIFx
10.0
70.0
BEDROOM3
c 2839
53
118
0,080
6.0
OxO
VIFx
9.8
70.0
LNBJGMRCHEN-A
C 5707
54
237
0.080
8.0
Ox0
VIFx
6.0
70.0
uwNl
c 5707
54
237
0.080
8.0
OxO
VIFx
1 5.1
70.0
Grille
Htg
Clg
TEL
Design
Meloc
Diam
H x W
Stud/Joist
Dud
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Mat
Trunk
rb3
Ox0
56
243
0
0
0
0
Ox 0
VIFx
rb1
Ox0
165
478
0
0
0
0
Ox 0
VIFx
rb2
Ox0
91
213
0
0
0
0
Ox 0
VIFx
BoldStaft values have been manually overridden
wrightsoR' 2019-May-2808:51.45
^'� ...+•.`.�. RigltSuleOUiwmal 201919.0.07 RSU08101 Pagel
ACCA ...KOo rlslWdgW.OftWACUONES,MARGARETrtp Calc=Ml8 Rod Doorfares: S
1
O-. .
1�1BEDROOM
M
BATH
• ���' `
. f�E111h0 ill�`'fG�w'""M'"'"��
of,
BEDROOM 1
LRANGXITCHEW „
-237 ctn
14X8X8
ortred for.
QUICK CALCS, INC.
S a `�
3PRErJONES
)SLOA317SLWCELANE
Paa gel
Pa
MCE,FL3W47 CC 349
FORTPERCF, 34M
PhOW772-0ffi457W
19DURM08101
2019-MW28075208
QUICKCALCS@AOLCOM
4ftcftWACUCN6iMAR&REftW