HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MARGARET JONES Builder Name: SUANNED Street: 3410 SLOAN RD. Permit Office: ST. LUCIE COUNTY BY City, State, Zip: Fr. PIERCE, FL, Permit Number. St. Lucie Countv Owner: MARGARET JONES Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types(1056.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1056.00 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedroom�Bedrms In Addition) 3(3) d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (951.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 951.00 ft 6. Conditioned floor area above grade (ft2) 948 b. WA R= ft' Conditioned floor area below grade Ift) 0 c. WA R= ft' 11. Duds R ft' 7. Windows(126.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 125 a. U-Factor: Sgl, U=0.79 126.00 ft' SHGC: SHGC=0.48 b. U-Factor. N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 28.0 SEER:15.10 c. U-Factor N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.480 14. Hot water systems - None required 8. Floor Types (948.0 sqft.) Insulation Area a. Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 948.00 ft' b. Conservation features EF: 0.000 b. N/A R= ft' c. WA R= ft2 15. Credits Pstat Glass/Floor Area: 0.133 Total Proposed Modified Loads: 36.48 PASS Total Baseline Loads: 37.87 1 hereby certify that the plans and specifications covered by Review of the plans and STgl� this calculation are in compliance with the Florida Energy specifications covered by this O�THE �} , _ ; O Code. calculation indicates compliance yt ir,I ryOj ' ' with the Florida Energy Code. 1; nr,,�'Y4v, :;;;€-•`;a'=„�O PREPA Y Before construction is completed r a DATE: this building will be inspected for compliance with Section 553.908 �� t7 y ° I hereby certify that IN bull ing, as desig d, is in compliance Florida Statutes. with the Florida Ener y Co COp WE tip OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 5/28/2019 8:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPi:-.. SUMMARY CHECKLIST REPOR' PROJECT Title: MARGARETJONES Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 948 Lot # Owner Name: MARGARET JONES Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3410 SLOAN RD. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 948 7584 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 1 276 2208 No 2 1 1 Yes Yes Yes 2 BEDROOM 3 120 960 No 1 1 1 Yes Yes Yes 3 BEDROOM 2 96 768 No 1 1 1 Yes Yes Yes 4 BATH 35 280 No 0 1 No Yes Yes 5 Room5 45 360 No 0 1 No Yes Yes 6 A/C 15 120 No 0 1 No Yes Yes 7 LIVING/KITCHEN 361 2888 Yes 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 1 50 ft 0 276 ft' _- 0 1 0 2 Slab -On -Grade Edge Insulatio BEDROOM 3 22 ft 0 120 ft' _ 0 1 0 3 Slab -On -Grade Edge Insulatio BEDROOM 2 18 ft 0 96 ft' __ 0 1 0 4 Slab -On -Grade Edge Insulatio BATH 1 ft 0 35 ft' -_ 0 1 0 5 Slab -On -Grade Edge Insulatio Room5 1 ft 0 45 ft' — 0 1 0 6 Slab -On -Grade Edge Insulatio A/C 1 ft 0 15 ft' ___ 0 1 0 7SIab-On-Grade Edge Insulatio LIVING/KITCHEN 42 ft 0 361 ft' _- 0 1 0 5/28/2019 8:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INP SUMMARY CHECKLIST REPOR' ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 999 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 160 948 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 1 30 Blown 279 ft- 0.1 Wood 2 Under Attic (Vented) BEDROOM 3 30 Blown 120 ft' 0.1 Wood 3 Under Attic (Vented) BEDROOM 2 30 Blown 96 ft' 0.1 Wood 4 Under Attic (Vented) BATH 30 Blown 35 ft- 0.1 Wood 5 Under Attic (Vented) Room5 30 Blown 45 W 0.1 Wood 6 Under Attic (Vented) A/C 30 Blown 15 ft- 0.1 Wood 7 Under Attic (Vented) LIVING/KITCHEN 30 Blown 361 ft- 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Ext InfiEDROOM 1 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 2 E Exterior Concrete Block - Ext IndiEDROOM 1 4.1 13 0 8 0 104.0 ft- 0 0 0.4 0 3 S Exterior Concrete Block - Ext IndIEDROOM 1 4.1 23 0 8 0 184.0 ft- 0 0 0.4 0 4 W Exterior Concrete Block - Ext IndiIEDROOM 1 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 5 N Exterior Concrete Block - Ext IndiffDROOM 3 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 6 E Exterior Concrete Block - Ext IndilEDROOM 3 4.1 12 0 8 0 96.0 fN 0 0 0.4 0 7 E Exterior Concrete Block - Ext InfilEDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 8 S Exterior Concrete Block - Ext InREDROOM 2 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 9 N Exterior Concrete Block - Ext InddVING/KITC 4.1 18 0 8 0 144.0 ft' 0 0 0.4 0 10 W Exterior Concrete Block - Ext InddIJING/KITC 4.1 24 0 8 0 192.0 ft' 0 0 0.4 0 WINDOWS Orientation shown is the entered, Proposed orientation. _ / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Single (Clear) Yes 0.79 0.48 N 24.0 ft' 2 ft 0 in 1 ft4 in None None 2 W 4 Metal Single (Clear) Yes 0.79 0.48 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None 3 N 5 Metal Single (Clear) Yes 0.79 0.48 N 12.0 ft' 2 ft 0 in 1 ft4 in None None 4 E 6 Metal Single (Clear) Yes 0.79 0.48 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 7 Metal Single (Clear) Yes 0.79 0.48 N 12.0 ft' 2 ft 0 in 1 ft 4 in None None 6 N 9 Metal Single (Clear) Yes 0.79 0.48 N 12.0 ft' 2 ft 0 in 1 ft 4 in None None 7 W 10 Metal Single (Clear) Yes 0.79 0.48 N 9.0 ft' 2 ft 0 in 1 ft 4 in None None 8 W 10 Metal Single (Clear) Yes 0.79 0.48 N 30.0 ft' 2 ft 0 in 1 ft 4 in None None 5/28/2019 8:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INP • ..'SUMMARY CHECKLIST REPOR INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 632 34.7 65.25 .0881 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Strip HeatlSupplemen None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for Split SEER: 15.1 28 kBtu/hr cfm 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF ft' DUCTS J — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft' Attic 65 ft' Default Leakage A/C (Default) (Default) 1 1 TEMPERATURES Programablee(,]Thermostat: Y Ceiling Fans:Cooling Feb [[[[XX Venting Feb Mar f Apr Mayr[[ ]] Jun Jul �X [[ ]] [ Aug [X] Sep [ j [[X]] LJ Dec (Jan [ ]Jan X� Mov ay lxl Jun [ Jul LKl [ Aug [( ]I Sep lxl Occtt [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM 1 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 Room5 Default(8 lbs/sq.ft. ft' ft 0.3 A/C Default(8 Ibs/s .ft. ft' It 0.3 LIVINGIKITCHEN 5/28/2019 8:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 -AIR BARRIER AND INSL^=__rION INSPECTION COMPONENT t _", ERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MARGARET JONES Builder Name: Street: 3410 SLOAN RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner. MARGARET JONES Jurisdiction: _ Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to - exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light factures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Dinino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/28/2019 8:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location A/C 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.0 a) Split system SEER 15.1 5. Is this a worst rase? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 948 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.790 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.480 14. Heating system: Capacity 17.0 c) Area 7c. 126.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1 la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be i stalled (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be compl9t�ld ased on installegWode compliant features. Builder Signature: /(it/�� Date: 0�T Address of New Home/ 3410 SLOAN RD. City/FL Zip: FT. PIERCE. FL 5/28/2019 8:05:28 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 + wrightsofte r� Project Summary Enbre House QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Kam 772-466-6799 Email: OUICKCALCS@A0LC0M Project• • For. MARGARET JONES 3410 SLOAN RD., FT. PIERCE, FL34947 Notes: Job: Data: By. Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15737 Btuh Structure 18234 Btuh Duds 3056 Btuh Ducts 4234 Btuh Central vent (0 cfin) 0 Btuh Central vent (0 c1m) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18793 Btuh Use manufacturers data n Rate/swingg multipplier Equipmenisensibleload 0.95 21345 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2599 Btuh Ducts 1205 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool' (none) Area (ft� 971 971 Equipment latent load 3805 Btuh Wlume 8739 8739 Airchangeslhour OA5 0.23 Equipment Total Load (Sen+Lat) 25150 Btuh Equiv. AVF (cBT1) 66 33 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond 14ACX-030-230A** AHRI ref Coil CBA25UHV-030-23V* AHRI ref 202540515 Efficiency 100 EFF Efficiency 12.5 EER,15.1 SEER Heatinglnput 5.0 WV Sensible000ling 19600 Btuh Heating output 17156 Btuh Latent000ling 8400 Btuh Temperature rise 50 OF Total cooling 28000 Btuh Actual airflow 312 dm Actual airflow 933 cfin Airflowfactor 0.017 cfmBtuh Airflowfactor 0.042 cfmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. wrights ft- 2019-May-2808..05554 ���..� •..,.., Ri9M-Stile®Uriversa1201919.0.07 RSW8101 Page I ...KMDcaa TMWdghmftHVACUONES,MARGARETnp Calc=MI8 Fmit Dwrfaces: S I wrightsoftRight-M Worksheet Job: Entire House Date: QUICK CALCS, INC. sr 317ST, LUCIE LANE, FORTPIERCE,FL34946 Ptcm:772-466-6799 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name ftmedwell Room height Room dimensions Room area FsBre House 1320 ft 9.0 ft 971.0 W BEDROOM 50.0 It 9.0 It heaVcool 13.0 x 23.0 ft 299.0 W Ty Consbucdm number U-Ndue (BUTAIft `F) Or HTM (BtuK" Area (fe) or perimeter (ft) Load (Btuh) Area or perimeter (fl) Load (Bluh) Heat I Cod Gross NOS Heat Cod Gross N/PIS Heat Cod 6 11 -ll44!! _G — —949 —M 1237 853 —949 1553 1117 320 1600 519 13A- 1Ac1am 0.143 _1270 n _n_, a _e_ s _s_ w w w 4.00 ._.35.56 4.00 35.56 4.00 _35.56 4.00 35.56 35.56 219 —34.77 219 85.05 _219 .a34.77. 219 84.36 87.06 _,2.45 0.00 251 __24 333 24 _ 261 —24 333 9 45 _97.1, 237 ___0 309 2 9 9 36 0 20 LQ! �--G �—< 13A4= 1AKl= 13A� 1Ac10n 0.143 1270 0.143 _835 676 2065 ^ 519 _835 610 759 3918 _2379 0 —0 117 _0 207 �24 117 0 15 =298 299 —0 117 0 783 24 102 0 1 468 _ 0 733 _853 40B 0 533 .,_ 410 1385 —A 256 _ o 400 835 223 0 1306 �,733 0 237 �24, 279 1 3 4pJ L�—GG .C_ F 13A = 1A-dom 1A-dom 168.19atl 22LW �1270 0.143 1270 1270 �0.049 0.969 — � = � �1_.32 2T69 �07.1. 132 =1392 3655 _299 50 971 _—_ 61 c)AED e>mzdm 1188 241 Envelopelossrgain 13720 14302 4827 4014 12 a) Mltaton b) Roon %,erNlatim 2017 0 552 0 764 0 209 0 13 fnleMal gaits Oovpanl5@ 230 Appliarlomofller 6 1380 2DO01 2 I 460 1 0 Subbtal Qines6b 13) 15737 18234 5591 4683 14 15 Lesse&rral load Lessfransfer Redisbibuton Subbtzl Ductloads 19% 23% 0 0 0 15737 3056 0 0 0 18234 4234 190/0 23% 0 0 13 5605 1088 0 0 23 4705 1093 Total room load Airrequired(cim) 18793 312 22468 933 6693 111 5798 241 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. =RQN . t- 2019-May-280895:54 AC& -^ Rigtt-Shce®Udversa1201919.0.07 RSU08101 Pagel ...KOoa rts\WdgtboftWACUONES,MARGARETnp Calc=MIB Frort Doorfaces: S wrightsoft• Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST.. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS AOL.COM Job: Date: By: 1 2 3 4 5 Room name Eposedwall Rcom height Rcom dimensions Raamarea BEDROOM3 22.0 ft 9.0 ft head000l 12.0 x 10.0 ft 120.0 ft BEDROOM2 18.0 a 9.0 ft heaftd 120 x 8.0 ft 95.0 ft' Ty Construmon number U-value (Bluhfti'q Or HTM (Bfuhln Area (fF) or penmeler (ft) Load AM) Area (fe) or perimeter (ft) Load (Btah) Heat I Cad Gross N/PIS Heat Cool Gross N/P/S Heat Cod 6 11 11qqJJ -. 13A-0o6 JA-dom— 0.143 .,..a_1270 n _.n_ a a n vs_ w w w =; - 4.00 -35.56 4.00 3556 4.00 35.56 4.00 35.56 35.56 = 37 27.69 219 _34.77. 219 86.05 219 —34.77 219 84.36 87.06 ,e 245 0.00 90 ______12 108 12 —78 312 427. 171 417 0 0— 0 0 --0 lqJ . U�J� `C 13A-4= 1Aclom 13X4&i JA-c1bm 13A4= 1Ac1om 1Ac1om J6&19ad 22A-fpl o.143 1270 0.143 1270 �0.16 1270 1270 =6049 0.969 —0. 96 1. 384 427 210 1033 —0 108 12 —0 96 1 384 427 —0 210 1033 —118 --0 —0 0 0 0 V120 120 0 _.-0 0 0 �_0 ,_,—.,.,120 22 — 6 0 ' 0' 54 0 - 54 —0-0 0 0 ______0 - 96 216 l/tJ LI—(C` = —0 0 0 0 ,®®_165 0 0 0 '=294 0 0 ,0 — 96 0 0 0 ___eJ32 498 —0 0 0 v_.,___..0 �..�235 0 _ ;C� F 609 0 96 18 6 c)AED exarson -142 52 Ernelope loss/gain 2324 1982 1657 1544 12 a) Infiltration b) Room ventilation 336 0 92 0 275 0 75 0 13 Inlernalgains O—Pants@ 230 Appliancestother 1 230 0 1 1 230 1 0 Subtotal (lines6 t313) 2660 2304 1933 1849 14 15 Lesse#enralload Lesstrarrsrer Redistribution SubDobl Dudloads 190/0 23- 0 0 0 2560 517 0 0 0 2304 535 19% 23% 0 0 0 1933 375 0 0 0 1849 429 Total room load Airregdred(dm) 3177 53 2839 118 2308 38 2279 95 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -PW wrighiso�f^[- 2019-May-2808:05:54 A%k •-^ - Rig"Ute®Uriversal 201919.0.07 RSU08101 Paget .K\Dume ..orts\WdgltsoftHVACUONES,MARGARETnp Calc=Ml8 FrontDoorfaces: S +wrightsoftRight-J®Worksheet Job: Entire House Date: QUICK CALLS, INC, sy 317ST. LUCIE LANE, FORTPIERCE, FL34946 Plrm:772366-6799 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Roan rune EVosedwall Roan height Room dimensions Roan area RATH O ft 9.0 ft heaticod 7.0 x 5.0 It 35.0 fe Room5 O ft 9.0 ft heaVood 9.0 x 5.0 ft 45.0 fe Ty Consbvcfion number U-value (BWhdt *q Or HTM (Bluh" Area (W) or perimeter (ft) Load (Btuh) Area (fF) or permeter (ft) Load (Btuh) Heat I Cod Gross NOS Halt Cool Gross NIPS Heat Cod 6 11 lrrl 13A-0ocs JAc1Cm 0.143 ,.-�1270 n „_n_ a _e 5 -s_ w w w 4.00 _35.56 4.00 _35.56 4.00 �35.56 4.00 35.56 35.56 219 -34.77 2.19 86.05 " 2.19 -34.7Z Z19 84.36 87.06 0 ,.__0 0 0 -6--6--0 -0. 0 0 0 0 --0 0 0 -0 0 0 0 0 0 0 0 0 0 0 '-0 �0 0 0 -"'--0 .-0 Y�J I--G _.- 44ppJJ `C 13AAo s 1Ac1am 13A4as 1Ac1om- 0.143 1270 0:143 . - 270 0.143 1270 1270 ___-__0 0 0 0 0 0 -0-0-0-0 0 0 �'�0 _0 0 0 Y'-0 �0. 0 0 ��0 13AAors 1Ac1om 1Aytom 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IF F 18&'19ad 22A�1p1 �0.989 0.989 - ,� 7.69 27.69 _. 0.00 0.00 35 35 30 0 ,a,�_40 0 , 80 =45 ___-_,,. 45 �, --6 . �_..,�62 „_110 0 45 0 8 C)AED exalraorl -5 -6 Envelope lossgain 48 81 62 104 12 a) Infiltration b) Room wifilaim 0 0 0 Ol 0 1 0 0 0 13 InMmd gains Oavparhss@ 230 Appliarxeslotw 0 0 0 0 0 0 Subtdal(lines(S b 13) 48 81 62 104 14 15 Lesse)lemal load Lesstransfer Redisdbutm Submlal Ductloads 19% 23% 0 0 19 67 13 0 0 32 112 28 190/0 23% 0 0 -62 0 0 0 0 -104 0 0 Tolal mom load Airrequired (dm) 80 1 138 6 0 0 0 0 _ Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrYgtitsof t- 2019-May-2808:05:54 A&k - RigfFSUteOUriv =1201919.0.07RSW8101 Page _H�MrtslWdgtLroftWACUONES,MARGARET.np CaIc=MI8 Frorl Doorfaces' S t ' wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. sy 317ST. LUCIE LANE, FORTPIERCE, FL34946 PPore:772-466-6799 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Roan name EVOsedwall Roan height Room dimensions Roxn area P/C 0 ft 9.0 it he8V0]C9 3.0 x 5.0 It 15.0 IF LMNGKITCHEN 420 ft 9.0 ft heaVoxi 1.0 x 361.0 It 361.0 IF Ty Conshdw number U-value (BtuhTe-'F) Or HTM (BLh*) Area (IF) x perimeter (ft) Load (Btuh) Area (ft� or perimeter Qt) Load (BUh) Heat Cad Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 11 13P.-' JAcIom —0.143 n _n_ a _s_ w w w 400 _,_35.56 4.00 _35.56 4.00 35.56 35.56 e_. �1.37 27.69 2]8 _,_,34.77_ 219 —34.77. 219 84.36 97.06 T_ ,_2.45 0.00 0 0 0 �0 - 6 —0 0 0 0 — 162 12 150 _601 427 0 328 _ 417. 0 „-0 lQJ `G 13A-40cs 13 _1Aciom _1270 0.143 e12700 0.143 1270 1270 0 —0. 0 0 0 10 0 `0 0 0 —0 0 i — 13A-0as 1Aclan IAclOm 18&19ad ..._�Q989 22A-ml 0 0 0 _'16.. 15 —0-0-0-0-0 0 0 0 0 0 0 216 9 30 177 1 21067 709 320 387 759 2612 C F 0.989 - 0 0 =30 0 ,� 361 361 `342 42 1163 1183 860 0 0 6 o)AEDeminzi n -2 1155 Ernelope lossigain 21 35 4781 6543 12 a) Witation b) Roomvenblalim 0 1 0 0 Ol 642 0 176 0 13 Internal gains O=pants@ 230 Applianoe.4ofher 0 0 0 2 460 20M Subbtal(Ims6 to 13) 21 35 5423 9179 14 15 Lessa#emalload Lesstransfer Redistribution Subtotal Ductloads 19% 23% 0 0 -21 0 0 0 0 -35 0 0 19% 239/6 0 0 50 5473 1063 0 0 84 9263 2151 Total roan load Airrequired(dm) 0 0 0 0 6536 109 11414 474 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. wrlghiso_it- 2019-M%,2808:05:54 A& Rigt4Sdte&Udversal 201919.0.07 RSU08101 Page 4 ...Krpoa its\WdgFfsoftHVACUONES,MARGARETnQ Calc=Ml8 FrortDoorfaces: S l Ducstem Summary Job: �- wrightsoft t System rY oar: Entire House By. QUICK CALCS, INC. 317ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 7724688799 Email: QUICKCALCS@AOL.COM For. MARGARETJONES 3410 SLOAN RD., FT. PIERCE, FL34947 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.28 in H2O 0.28 in H2O Available static pressure 0.22 in H2O 0.22 in H2O Supply/return available pressure 0.11010.110 in H2O 0.110/0.110 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual airflow 312 cfrrl 933 clim Total effective length (TEL) 81 ft Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FIR Diam (in) HxW (in) Dud Mat Actual Ln (it) Ftg.Egv Ln (ft) Trunk BATH c 138 1 6 0.080 4.0 Ox0 VIFx 5.0 70.0 BEDROOM 1 c 5798 111 241 0.080 8.0 OxO VIFx 11 A 70.0 BEDROOM2 c 2279 38 95 0.080 6.0 Ox0 VIFx 10.0 70.0 BEDROOM3 c 2839 53 118 0,080 6.0 OxO VIFx 9.8 70.0 LNBJGMRCHEN-A C 5707 54 237 0.080 8.0 Ox0 VIFx 6.0 70.0 uwNl c 5707 54 237 0.080 8.0 OxO VIFx 1 5.1 70.0 Grille Htg Clg TEL Design Meloc Diam H x W Stud/Joist Dud Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk rb3 Ox0 56 243 0 0 0 0 Ox 0 VIFx rb1 Ox0 165 478 0 0 0 0 Ox 0 VIFx rb2 Ox0 91 213 0 0 0 0 Ox 0 VIFx BoldStaft values have been manually overridden wrightsoR' 2019-May-2808:51.45 ^'� ...+•.`.�. RigltSuleOUiwmal 201919.0.07 RSU08101 Pagel ACCA ...KOo rlslWdgW.OftWACUONES,MARGARETrtp Calc=Ml8 Rod Doorfares: S 1 O-. . 1�1BEDROOM M BATH • ���' ` . f�E111h0 ill�`'fG�w'""M'"'"�� of, BEDROOM 1 LRANGXITCHEW „ -237 ctn 14X8X8 ortred for. QUICK CALCS, INC. S a `� 3PRErJONES )SLOA317SLWCELANE Paa gel Pa MCE,FL3W47 CC 349 FORTPERCF, 34M PhOW772-0ffi457W 19DURM08101 2019-MW28075208 QUICKCALCS@AOLCOM 4ftcftWACUCN6iMAR&REftW