HomeMy WebLinkAboutREVISION - BUIILDING PEMITJ
OFFICE USE ONLY:
DATE FILED•
k a:) ?C
REVISION FEE:
PERMIT # 1905-0746
RECEIPT# {'
PLANNING & DEVELOPMENT SERVICES BY
BUILDING & CODE REGULATION DIVISION St. Lucie CiOMAY
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
553
APPLICATION FOR BUILDING PERMIT REVISIONS'LE CO
PROJECT INFORMATION N011S
LOCATION/SITE e
ADDRESS:
1405 PLATTS LANE. FORT PIERCE
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CHANGE TO POLYGLASS 3-PLY SYSTEM (W-131) INSTEAD OF INSULATION AND MODIFIED
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1325895
BUSINESS NAME: JA TAYLOR ROOFING INC
QUALIFIERS NAME: KYLE WHITE
ADDRESS: 302 MELTON DR
CITY: FT PIERCE STATE -
PHONE (DAYTIME): 772-466-4040
OWNER/BUILDER INFORMATION:
NAME: N/A
CITY:
PHONE (DAYTIME:
FL
STATE:
ARCHITECT/ENGINEER INFORMATION:
NAME: WA
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130117
STATE:
ST. LUCIE CO CERT. #: 23018
ME"
I
ZIP: 34982
772-468-8397
ZIP:
AUG 2 2 2019
Permitting Department
St. Lucie County, FL
R7 St, Lucie County 0*&&
Permit 19050746
Permit Sums: Issued
Job I)wmfpam FLAT ROOF ONLY, TEAR OFF MODIFIM ROOF, RENAIL DECK INSTALL NEW POLYGLASS (W-61) MODIFIED BTITIMEN ROOF SYSTEM (RJ1654.1)
5GOSQ.F1.
To pay a raimpection fee, please click PyFM link for esch fee due. You may use Visa, MarUnro:4, Discow Card.
= ocheck to pay dw fire using the Govueller grtway.
To schedule sm Inapecdon, plarso, select Request far cach inspection yon would 10a, to schedule. 1wPectiom mW be scheduled in the order oftho Primiry listed below. An mspedon M
not schedule uroll all inspectioms with a louvenrPrio* number show = "Approved" seems red ALL rciespeclion fees have heart PAID.
To add a•note for the IMector for scheduled inspections, plesso salare Add care now in InspectionNotes undbox: below, and click Update link far each inspectim you would bilm
to add a nme in
Ifyoumumbletoschc&Oe=hispecdon"rcqumeanyoasis m pleaseooNazttbeBm'lftDiyWmd(M)462-2172.
1y1
rbtl
Scum . 1Pemltlype
Name
rmway
I
PtyCe
ft
Contracter
MOM
AcUm
ROOF- MODIFIED lUTUMM
I
JATAWRRWRNGMC
(37Z) 456�10
P.que,t
;,ti Note
Pay F
1Fee1
code
soom
I ftft I
uctcl.,coed
Lu;,ro
lrsmWOa
LLWedbn wsso,
Add New
payree
134-ROOF
Amesbcl
I
SAV"19
8A4M19
0
F RDDFARIDAWEI@ v
SWI G
Add Mla
Pay Fee
Acombel
1
EV1412DI9
8/14f20
0
PERROOFARIDAVIr51GtlFD BY
INYO
as rcRed
CONiRACIOROFR AHUMM�
AddNrte
Pay Fee
PamWWW
2
8mfnlg
8/19POV)
S
co�.P*&e
NAr1WAYPOIM
TMAppmM.
oppw, �W 4�
ap;Ccdmps�lsoe&�*are
W�6/161s019
1,38W PIN.
MdNoo,
Pay Fee
DRYIN"
2
TAS
Md NOM
Pay Fes
FASRiBS
3
Add NOR
Pay Fee
N
3
Iyotr- b-7y�
REVIEWED F
CODE COMPL CE
ST. LUCIE C UNTY
BOCC
%It 20\9
V:a cool
ONEMOjetc.
APPENDIX
TABLE
1: ATTACHM ENT REQUIREMENTS FOR WIND
DECK
UPLIFT RESISTANCE
APPLICATION
TYPE
DESCRIPTION
PAGE
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
SB
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
1C
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
ID
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
12
1E
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-14
1F
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
15-18
1G
I Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
18-22
1H
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
23-28
11
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
29
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
30.32
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
33-37
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-1
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
38-39
2D
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mech. Attached Velociflex, Bonded Roof Cover
40-41
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
42-50
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
50
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
51-53
48
Lightweight concrete
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
54
4C
Lightweight concrete
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
55-58
5A
Cementitlous wood Ober
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
59
513
Cementitious wood Ober
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
60
Sc
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
61
SO
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
61
5E
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
61
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
62-64
6B
Existing gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
64
6C
Existing gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
64
6D
Existing gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
64
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
65-69
78
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
69
The following notes apoly to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-Inch embedment Into pilot hole In accordance with fastener manufacturer's published Installation Instructions.
NEMO ETC, LLC Evaluation Report P9290.02.08-RZ2 for FL1654-1124
Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 69
ONEMOletc.
3. Unless otherwise noted, insulation maybe anyone layer or combination of polylsocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the OA requirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete maybe substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet
fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural
members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval
documentation.
5. Preliminary Insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width Is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published Instructions.
➢ Hot asphalt (HA):
Full coverage at 25-30lbs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS):
Continuous 0.75 to 1-Inch wide. ribbons, 12-Inch o.c.
D Millennium One Step Foamable Adhesive(M-OSFA):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c.
D Millennium PG-1 Pump Grade Adhesive (M-PG1):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c.
D OMG OlyBond 500 (OB500):
Continuous 0.75 to 1-Inch wide ribbons,12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
D OlyBond Classic (OB Classic):
Full coverage at 1 gal/square.
D ICP Adhesive & Sealants Polyset CR-20:
Continuous 2.5-3.5-Inch wide ribbons,12-Inch o.c.
D Note: When multiple layers(s) of insulation and/or coverboard are Installed In ribbon -applied adhesive, board joints shall be staggered.
D Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polylsocyanurate at the following thickness limitations maybe substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MOP listings In the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the
thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: '
D Millennium One Step Foamable Adhesive(M-OSFA):
MDP -157.5 psf (Min. 0.5-inch thick)
D Millennium PG-1 Pump Grade Adhesive(M-PG3):
MDP -157.S psf (Min. 0.5-inch thick)
D OMG OlyBond 500 (013500):
MDP -45.0 psf (Min. 0.5-Inch thick Multi -Max FA-3)
D OMG OlyBond 500 (OB500):
MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+GL)
D OMG OlyBond 500 (OB500):
MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3)
D OMG OlyBond 500 (OB500):
MDP -487.5 psf (Min. 0.5-Inch thick ACFoam II)
D ICP Adhesives& Sealants Polyset CR-20:
MDP -117.S psf (Min. 1.0-inch thick)
8. Bonded polylsocyanurate insulation boards shall be maximum 4x 4 ft.
9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk" carry the limitations set forth In Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements. -
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (far recover) shall be capable of resisting project design pressures on Its own merit to the satisfaction of the AuthorityHaving Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the Insulation Is optional; however, the existing roof system shall be suitable for a recover application.
NEMO ETC, LLC
Certificate of Authorization #32455
Prepared by: Robert Nleminen, PE-59166
6" EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233.1330
Evaluation Report P9290.02.08-R22 for FL3654-R24
Revision 22: 04/11/2019
Appendix 1, Page 2 of 69
NNEMOjetc.
14. Lightweight Insulating Concrete (LWC) shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat
thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Paint 1. For "pre-existent' LWC references, listings were established through testing over lightweight concrete cast
using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted,
use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications
POLYGLAss ROOF
REFERENCE
LAYER
I MATERIAL
APPLICATION
BP -AA
Base Ply
One or more lies Polyglass G2 Base, FBC Approved ASTM D4601, Type 11
Hot Asphalt at 20-40
(Base and Ply sheets,
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Ibs/square
Asphalt -Applied)
Note:
Asphalt -applied sheets or Insulation shall not be applied to poly -film surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex 56 HP, Elastoshleld HT
PG350 at 1.5-2.0
SBS-CAI
Elastoflex V G, Elastoflex V G FR, Elastoflex 56, Elastoflex S6 HP, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshleld TS G, Elastoshield TS
gal/square
Cap Ply
G FRI, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 HP
Polyplus 35 at 1.5-2.0
SBS-CA2
Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshleld TS
Cap Ply
G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
gal/square
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
SBS-AA
Base Ply or Ply
S6 HP, Elastoshield HT
Hot Asphalt at 20.40
(SBS, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex V G; Elastoflex V G FR, Elastoflex S6, Elastoflex 56 HP, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS G,
Ibs/square
Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or Insulation shall not be applied to poly -film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex 56 HP, Elastoshield HT
SBS-TA
Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex 56, Elastoflex S6 HP, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS G,
Torch -Applied
(SBS, Torch -Applied)
Cap Ply
Elastoshleld TS G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V, Elastoflex SA V Fit, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P Fit, Polyreflect
Self
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substratesfors85-SA are limited to the SBS-SA Base Ply options herein,
-Adhering
Elastobase (Poly/sand) or Elastobase (poly/poly).
APP-CAI
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass Base, Polyflex, Polybond
Torch
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
-Applied
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP SA
Note:
Unless otherwise noted, permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
(APP, Self -Adhering)
Elastobase (poly/sand) or Elastobase (poly/poly).
NEMO ETC, LLC Evaluation Report P9290.02.08-R22 for FL3654-R24
Certificate of Authorization #32455 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 69
16. Vapor barrier options for use over structural concrete deck followed by adhered Insulation carry the following Maximum Design Pressure (MDP) limitations.
applies:
fONEMOjetc.
The lesser of the MDP listings below vs. those In Table 3A
OPTION
#
PRIMER
OPTIONS;VAPOR BARRIER STRUCTURAL CONCRETE DECK;
VAPOR BARRIER
"ATTACH
INSULATION. ADHESIVE
MDP (PSF)
TYPE
`
VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stlk or CR-20, 12-Inch D.C.
-60.0
. VB-2.
PG100
Polyglass Base
Torch -applied
Inta-Stik or CR-20, 12-inch D.C.
-75.0
VB-3.
PG100
Elastoflex SAP
Self -Adhering
Insta-Stik, 12-Inch D.C.
-75.0
VB-4.
PG100
Elastoflex SAP
Self -Adhering
Millennium One Step Foamable Adhesive,12-inch D.C.
-157.5
VB-S.
PG100
Elastoflex SAP
Self -Adhering
CR-20, 12-inch D.C.
-270.0
VB-6.
PG100
Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V
Plus, Elastoflex SA V Plus FR
Self -Adhering
I
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-Inch D.C.
2900
17. The following surfacing maybe applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for
aoolicatlon limitations and a Roofing Materials Directory for fire ratings associated with coating usage.
Option #
SURFACING NS FOR POLYGI.ASS BITUMEN F SYSTEMS
•Surfacing MODIFIED ••
Florida Product Approval
SURF-1.
PG300 Fibered Roof Coating
FL10291
SURF-2.
PG600 Non-Fibered Aluminum Roof Coating
FL10291
SURF-3.
PG650 Fibered Aluminum Roof Coating
FL10291
SURF-4.
PG700 High Quality Elastomeric Roof Coating
FL10291
SURF-5.
PG7000S (Quick Set) High Quality Elastomeric Roof Coating
FL10291
SURF-6.
PG800 Asphalt Emulsion Roof Coating
FL10291
SURF-7.
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating
FL10291
SURF-8.
Polyplus 65 Premium Fibered Aluminum Roof Coating
FL10291
SURF-9.
Polybrite 70 Premium Grade Elastomeric Roof Coating
FL10291
SURF-30.
Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating
FL10291
SURF-11.
Polybrite 71 HS
FL10291
SURF-12.
Polybrite 90 High Solids Silicone Roof Coating
FL10291
SURF-13.
Polybrite 95 Silicone Roof Coating
FL10291
SURF-14.
KM Acryl 15
FL27409
SURF-15.
KM Acryl 15 QS
FL27409
SURF-16.
KM Acryl 25
FL27409
SURF-17.
KM Acryl 25 CIS
FL27409
SURF-18.
KM Acryl 40 HS
FL27409
SURF-19.
KM Acryl 85
FL27409
SURF-20.
KM PS4250
FL27409
SURF-21.
KM PS#220
FL27409
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO ETC, LLC Evaluation Report P9290.02.08-R22 for FL3654-R24
Certificate of Authorization #32455 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 69
t9
ONEMOletc.
TABLE 1G: WOOD . CONSTRUCTION ..
SYSTEMTYPEE: NON -INSULATED, MECHANICALLY ATTACHED BASE BONDED ROOF
System.
Base Sheet
Roof Cover (Note 151
MDP
No.
Deck (Note 1)
Type
Fasten
Attach
-Base Ply
.Cap Ply
(Psfl
APA rated, 7/16 CAT,
Simplex MAxx Cap
8-inch o.c. at min. 3-inch lap and 8-inch o.c. at
W-128
0.418In., Exposure 1
Elastobase (poly -film top)
Note:MAxX Cops are to be primed with PGl00 or
three(3), equally spaced, staggered center
SBS-SA
SBS-SA, APP-SA, SBS-
-60.0
OSB
ASTM D41 primer
rows
TA, APP-TA
APA rated plywood
ed plywood
rated
Min. 19/32-Inch
Elastobase, Elastobase P
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
8-inch a.c. at min. 4-inch lap and 8-inch o.c. at
SBS-SA, APP-SA, SBS-
W-129
plywood
(poly -film top)
ring shank nails
three (3), equally spaced, staggered center
SBS-SA
TA APP TA
-60.0
TOWS
Min. 19/32-Inch
Elastobase, Elastobase P
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
8-Inch o.c. at min. 4-Inch lap and 8-inch o.c. at
W-130
plywood
(poly -film top)
ring shank nails
three(3), equally spaced, staggered center
Polyflex SA Base
APP-TA
-60.0
rows
y131
VIg7
Min. 19/32-Inch
Elastobase, Elastobase P
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
flinch o.c. at min. flinch lap and flinch o.c. at
SBS-SA
SBS-SA, APP-SA, SBS-
5
C
-plywood
(poly -film top)
ring shank nails.
four(4), equally spaced, staggered center rows
TA,APP-TA
W-132
Min. 19/32-Inch
Elastobase, Elastobase P
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
flinch o.c. at min. flinch lap and flinch o.c. at
Paly#ex SA Base
APP-TA
-97.5
plywood
(poly -film top)
ring shank nails.
four(4), equally spaced, staggered center rows
Min. 19/32-Inch
Elastobase, Elastobase P
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
6-Inch o.c. at min. flinch lap and 6-Inch o.c. at
Elastofiex SA V Plus,
SBS-SA, APP-SA, SBS-
W-133
plywood
(poly -film top)
ring shank nails. Note: T/n caps are [o be primed with
four(4), equallyspaced, staggered center rows
Elastofiex SA V Plus
TA, APP-TA
-112.5
PG100 orASTM D4I primer.
FR
Min. 19/32-Inch
Elastobase, Elastobase P
32 ga.,1-5/8-Inch diameter tin caps with 11 ga. annular
5-inch o.c. at min. 4-Inch lap and 6-inch o.c. at
W-134
Plywood
(poly -film top)
ring shank nails. Note: Tin caps are to be primed with
four (4), equally spaced, staggered center rows
PolyflexSA Base
APP-TA
-112.5
PG100 or ASTM D41 primer.
I
NEMO ETC, LLC
Certificate of Authorization #32455
Prepared by: Robert Nieminen, PE-59166
6- EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233.1330
Evaluation Report P9290.02.08-R22 for FL1654-RZ4
Revision 22: 04/11/2019
Appendix 1, Page 22 of 69