Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCES� •" L J' 1 Planning & Development Services Department ° Building & Code Regulations Division RECEIVED ------ -- 2300VirginiaAvenue, Fort Pierce, FL34982—(772)462-1553 MAY S 12019 Certification for Design Load Compliance n, Lucie County, Permitting Project Name: Wade Jurney Homes -1402 ,er,nnlNED Project Address: 022LWP002 - 7105 Brookline ave Ft. Pierce, FL 34951 BY St. Lucre Cwty Permit INSTRUCTIONS FOR USE: Type: Construction This certification must be completed, signed, and sealed by the design professional of re§qEVI EWED FOR Submit (2) copies for residential, (3) copies for commercial with all permit applicatioCOVE t"OMPLIANCE o New Residences (single or multi -family) i.r o Residential Addition ST. LUCIE COUNTY o Any accessory structure requiring a building permit E®CiCr o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X II _III_IV Exposure Category:B X C _D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft 5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (13517, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.3.-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3, 78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,44.8 Garage: +31.7/-38.6 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y Yes NotApplicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also, jq ffi fyj� - - \/ structural elements depicted on these plans provide adequate resistaihce to the design force se�eti � c$ --• �., .� � �i. James G. Frilinq N it -n ATE�111 iigna j�fQ,C nOd $�0 /� toNr /j AI_ Revised 12/07/iid1$111111 Print Name ',Cent # & Co. Cert Auth. PE #77824 COA #27228 'ate Mulhern + Kulp StructuraLEng_Ineering - 300 Brookside Ave, Ambler, PA 19002 Company Name & Address,