HomeMy WebLinkAboutFIELD - LABORATORY REPORTA
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Ull5'Project No.: 0310.1900516.0003
Date Typed: December 11, 2019
RECIE
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 002 - 7105 Brookline Ave.
7105 Brookline Avenue, Ft. Pierce, Indian River County, FL
DEC 12 IBIS
Department
ie Col`^r
SCANNED
BY
St. Lucie County
As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or
field inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No.
I Data
I Type of Report
118357-1
1 11/25/2019
In -Place Density Test Report w/Activity Record
118427-1
1 11/26/2019
In -Place Density Test Report w/Activity Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
ICC Email: JT.Brenner@wadejumeyhomes.com
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization' No. 00 5�
,. Fa t:%a
21
.1e,f13j 1.5 1
D
} l,✓�jd`,,,'f41��7,i'�+%kno's�5`t}i
Richard E. Hoag11n;'PjE.,9
Professional Enqineer No. 48796
This item has been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital Signature. Printed
copies or this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
UNIVERSAL
118357-1
UES Report Noo:
ARC 12519
Ls!lENGINEERING SCIENCES On -Site Time (hrs): 0.50
Consultants In: Geotechnical Engineering • Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services - Materials Testing , Threshold Inspection Travel Time (hrs): 0.25
Building Code Administration, Compliance Inspection &Plan Review Total Time (hrs): 0.75
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 002 - 7105 Brookline Ave.
7105 Brookline Avenue, Ft. Pierce, Indian River County, FL
Date of Activity: Monday, 25 November, 2019
Technician: Russell Brause
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
House pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P:321.638.0808-F:321.638.0978
UES Project No: 0310.1900516.0003
UES DOCS No:
UES Report No: 118357-1 DT 112519
In -Place Density Test Report
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 002 - 7105 Brookline Ave.
7105 Brookline Avenue , Ft. Pierce, Indian River County, FL
Area Tested: House pad.
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 11/25/2019
Lab: ASTM D1557 Modified Proctor
Technician: Russell Brause
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvina soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
SW comer.
0 to -1 ft
12.00
9802
101.7
6.8
95
A
2
SE corner.
0 to -1 It
12.00
9802
102.6
11.1
96
A
3
NE corner.
0 to -1 ft
12.00
9802
102.2
10.2
96
A
4
NW corner.
0 to -1 ft
12.00
9802
102.6
10.7
96
A
(1) Ref. Datum: 0 = Top of Native
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
9802
107.0
12.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not he reproduced, except in full, without the written approval of Universal Engineering Sciences.
UE,�i-, +:Dject No: 0310.1900516.0003
LIES
U N I VERSAL
UES Report No: 118427-1 ARC 112619
ENGINEERING SCIENCES On -Site Time (hrs):0.25
Consultants In: Geotechnical Engineering • Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services • Materials Testing - Threshold Inspection Travel Time (hrs): 0.25
Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 0.50
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 002 - 7105 Brookline Ave.
7105 Brookline Avenue, Ft. Pierce, Indian River County, FL
Date of Activity: Tuesday, 26 November, 2019
Technician: Russell Brause
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
House pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
UES Project No: 0310.1900516.0003
UES DOCS No:
UES Report No: 118427-1 DT 112719
In -Place Density Test Report
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 002 - 7105 Brookline Ave.
7105 Brookline Avenue , Ft. Pierce, Indian River County, FL
Area Tested: House pad.
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 11/27/2019
Lab: ASTM D1557 Modified Proctor
Technician: Russell Brause
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvina soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
NW corner.
0 to -1 ft
12.00
9804
112.0
9.6
100
A
2
NE corner.
0 to -1 It
12.00
9804
112.6
12.1
101
A
3
SE corner.
0 to -1 It
12.00
9804
111.7
9.8
100
A
4
SW corner.
0 to -1 ft
12.00
9804
112.6
12.1
101
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
9804
112.0
11.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.