Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION / Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Evan Miller Residence Builder Name: SCANNED 5437 Ideal Holding Road Permit Office: St. Lucie County BY City, Stale, Zip: Fort Pierce , FL, 34987 Permit Number: Owner: Evan Miller Jurisdiction: St. Lucie County St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1563.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1563.20 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1426.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1426.00 ft2 6. Conditioned floor area above grade (ft2) 1426 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(95.5 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 120 a. U-Factor. Dbl, U=0.65 75.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 20.50 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.283 ft. Area Weighted Average SHGC: 0.261 14. Hot water systems 8. Floor Types (1426.0 sqft.) Insulation Area a. Propane Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 1426.00 ft2 b. Conservation features EF: 0.600 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 49.14 PASS Total Baseline Loads: 51.58 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this p,THESptl� �S' Code. calculation indicates compliance with the Florida Energy Code. rnxr`•.: {;;i�,;:x°„ �O PREPARED Y: Before construction is completed :4F DATE: '' this building will be inspected for compliance with Section 553.908 8 �. I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy ode. C'0 WE OWNER/AGE T: BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as bertified-factory-sealed in accordance with R403.3.2.1. A - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). RECEIVED 4/18/2019 10:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Softwar MAY 9 12019 age 1 of 5 Si. Lucie County, Permitting ti FORM R465-2D17 INPUT SUMMARY CHECKLIST KEPUKI PROJECT Title: Evan Miller Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1426 Lot # Owner Name: Evan Miller Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5437 Ideal Holding Roa Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34987 New/Fxisting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1426 13404.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Healed 1 Master Bath 113 1062.2 No 0 1 Yes Yes Yes 2 Closet 55 517 No 0 1 Yes Yes Yes 3 Master Bedroom 245 2303 No 2 1 1 Yes Yes Yes 4 Pantry 16 150.4 No 0 1 No Yes Yes 5 Laundry 60 564 No 0 1 Yes Yes Yes 6 Kitchen 104 977.6 Yes 2 1 No Yes Yes 7 Dining 121 1137.4 No 2 1 Yes Yes Yes 8 Bedroom 3 182 1710.8 No 1 1 1 Yes Yes Yes 9 Bathroom 64 507.6 No 0 1 Yes Yes Yes 10 Bedroom 2 169 1588.6 No 1 1 1 Yes Yes Yes 11 Hall 24 225.6 No 0 1 No Yes Yes 12 Great Room 283 2660.2 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Master Bath 23 It 0 113 ft' _ 1 0 0 2 Slab -On -Grade Edge Insulatio Closet lift 0 551t, _ 1 0 0 3 Slab -On -Grade Edge Insulatio Master Bedroom 31 ft 0 245 ft' _ 1 0 0 4-Slab-On-Grade Edge Insulatio Pantry 1 it 0 16 ft' _ 1 0 0 15 Slab -On -Grade Edge Insulatio Laundry 16 ft 0 60 It, — 1 0 0 4/18/2019 10:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 t FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT w FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio Kitchen 1 It 0 104 ft2 — 1 0 0 7 Slab -On -Grade Edge Insulatio Dining 4 It 0 121 ft2 _ 1 0 0 8 Slab -On -Grade Edge Insulatio Bedroom 3 32 ft 0 182 112 _ 1 0 0 9 Slab -On -Grade Edge Insulatio Bathroom 6 ft 0 54 ft2 _ 1 0 0 10SIab-On-Grade Edge Insulatio Bedroom 2 26 It 0 169 ft2 — 1 0 0 11Slab-On-Grade Edge Insulatio Hall 1 It 0 24 ft2 — 1 0 0 12SIab-On-Grade Edge Insulatio Great Room 17 ft 0 283 ft2 — 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1595 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1426 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Master Bath 20 Blown 113 ft2 0.1 Wood 2 Under Attic (Unvented) Closet 20 Blown 55 ft2 0.1 Wood 3 Under Attic (Unvented) Master Bedroom 20 Blown 245 ft- 0.1 Wood 4 Under Attic (Unvented) Pantry 20 Blown 16 ft2 0.1 Wood 5 Under Attic (Unvented) Laundry 20 Blown 60 ft2 0.1 Wood 6 Under Attic (Unvented) Kitchen 20 Blown 104 ft2 0.1 Wood 7 Under Attic (Unvented) Dining 20 Blown 121 ft2 0.1 Wood 8 Under Attic (Unvented) Bedroom 3 20 Blown 182 ft2 0.1 Wood 9 Under Attic (Unvented) Bathroom 20 Blown 54 ft2 0.1 Wood 10 Under Attic (Unvented) Bedroom 2 20 Blown 169 ft2 0.1 Wood _ 11 Under Attic (Unvented) Hall 20 Blown 24 ft2 0.1 Wood 12 Under Attic (Unvented) Great Room 20 Blown 283 112 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 S Exterior Concrete Block - Ext InsMaster Bath 4.1 7 0 9 5 65.9 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InsMaster Bath 4.1 16 0 9 5 150.7 ft2 0 0 0.6 0 _ 3 S Exterior Concrete Block - Ext Insul Closet 4.1 11 0 9 5 103.6 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Ext InNtister Bedro 4.1 14 0 9 5 131.8 ft2 0 0 0.6 0 4118/2019 10:32 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 5 S Exterior Concrete Block - Ext InMhster Bedro 4.1 16 0 9 5 150.7 ft' 0 0 0.6 0 -6 W Exterior Concrete Block - Ed Inddlister Bedro 4.1 1 0 9 5 9.4 ft' 0 0 0.6 0 -7 N Exterior Concrete Block- Ext Insul Laundry 4.1 6 0 9 5 56.5 ft' 0 0 0.6 0 _ 8 W Exterior Concrete Black - Ext Insul Laundry 4.1 10 0 9 5 94.2 ft' 0 0 0.6 0 -9 W Exterior Concrete Block - Ext Insul Dining 4.1 4 0 9 5 37.7 ft' 0 0 0.6 0 10 N Exterior Concrete Black - Ext Insd3edroom 3 4.1 14 0 9 5 131.8 ft2 0 0 0.6 0 _ 11 S Exterior Concrete Block - Ext Insdiledroom 3 4.1 5 0 9 5 47.1 ft' 0 0 0.6 0 _ 12 W Exterior Concrete Block- Ext InsiBedroom 3 4.1 13 0 9 5 122.4 ft' 0 0 0.6 0 _ 13 N Exterior Concrete Block- Ext InsuBalhroom 4.1 6 0 9 5 56.5 ft' 0 0 0.6 0 _ 14 N Exterior Concrete Block - Ext InsiBedroom 2 4.1 13 0 9 5 122.4 ft' 0 0 0.6 0 _ 15 E Exterior Concrete Block - Ext InsxBedroom 2 4.1 13 0 9 5 122A ft2 0 0 0.6 0 16 E Exterior Concrete Block - Ext Ins(Hreat Room 4.1 17 0 9 5 160.1 ft2 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Laundry None .39 2 10 6 10 19.4 ft' 2 E Wood Great Room None .39 3 6 10 20.5 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double Yes 0.65 0.25 N 7.5 ft' 1 It 7 in 1 ft 4 in None None 2 E 4 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 5 ft 0 in 1 It 4 in None None 3 W 9 Wood Low-E Double Yes 0.65 0.3 N 20.5 ft' 2 ft 0 in 1 ft 4 in None None 4 N 10 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 1 It 7 in 1 ft 4 in None None 5 N 13 Metal Low-E Double Yes 0.65 0.25 N 7.5 ft' 1 It 7 in 1 ft 4In None None _ 6 E 15 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 5 It 0 in 1 ft 4 in None None 7 E 16 Metal Low-E Double Yes 0.66 0.25 N 15.0 ft2 5 ft 0 in 1 It 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 1563.8 85.85 161.46 .318 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 S 4/18/2019 10:32 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 f FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / -- Supply — — Return— At CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 120 ft- Attic 30 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable T]hermosta�[t:]]Y Gelling Fans: Heating [X] Jan Feb [[ ]] pC] Mar Apr Mexl May Jun AugJul�rX�iX i rr Nov Nov Dec Venting [[ l) Jan [I )1 Feb l l [[fix]) Mar [ lApr Jun lxl Jul [ Aug [ Sep [X� Oct X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft- 0 ft 0.3 Master Bath Default(8 lbs/sq.ft. ft' ft 0.3 Closet Default(8 lbs/sq.fL ft' ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft' ft 0.3 Pantry Default(8 lbs/sq.ft. ft' ft 0.3 Laundry Default(8 lbs/sq.ft. ft' ft 0.3 Kitchen Default(8 lbs/sq.ft. ft' ft 0.3 Dining Default(8 lbs/sq.ft. ft ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. ft' ft 0.3 Bathroom Defaull(8-Ibs/sq.ft. ft' ft 0.3 Bedroom Default(8 lbslsq.ft. ft' ft 0.3 Hall Default 8lbsls A. ft' ft 0.3 Great Room Name: Signature: 4/18/2019Pr@.VpA'om(lant: EnergyGauge® USA Section tQ#3.qil UnopllwtS^tbver^ 4—` :�s Page 9 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Evan Miller Residence Builder Name: Street: 6437 Ideal Holding Road Permit Office: St. Lucie County City, Stale, Zip: Fort Pierce, FL, 34987 Permit Number. Owner: Evan Miller Jurisdiction: St. Lucie County = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit y pp 9 /soffit the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air border. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninina and Wrina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. hi ahhlmon, Inspecuvu ui luy waiiu shall be In accomance win me provisions Or 1GG-4UU. 4/18/2019 10:32 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 + + 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Att c 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1426 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.261 14. Heating system: Capacity 17.0 c) Area 7c. 95.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.60 A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11b, c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 30 / Address of New Home: _ 5437 Ideal Holding Road City/FL Zip: Fort Pierce, FL 34987 4/18/2019 10:32:44 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Job: wrightsoft' Entire House Byte. Quick Calcs, Inc. = 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickm1m@aol.com Promect Information For: Evan Miller 5437 Ideal Holding Road, Fort Pierce, FL 34987 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17949 Btuh Ducts 2368 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 20316 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatin Co1426 Area (ftJ 1426 Volume 13404 13404 Air changes/hour 0.45 0.23 Equiv. AVF (dm) 101 51 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow -Airflow-factor Static pressure Space thermostat Sensible Cooling Equipment Load Sizing Structure 15423 Btuh Duds 1604 Btuh Central vent (0 dm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 16176 Btuh Latent Cooling Equipment Load Sizing Structure 4146 Btuh Duds 1223 Btuh Central vent (0 dm) 0 Btuh (none) Equipment latent load 5370 Btuh Equipment Total Load (Sen+Lat) 21546 Btuh Req. total capacity at 0.70 SHR 1.9 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR40251-1 Coil TEM6AOB30H21++TDR AHRI ref 7567541 100 EFF Efficiency 6.0 kW Sensible cooling 20316 Btuh Latent cooling 23 OF Total cooling 800 dm Actual air flow 0.039 dm/Btuh Air flow 0.50 in H2O Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 16800 Btuh 7200 Btuh 24000 Btuh 800 dm 0.047 dm/Btuh 0.50 in H2O 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrlwtitsoft� 2019-Apr-1810:37:55 1-1 - -- Right-Suilc� U niversal 201919.0.01 RSU08101 Page ��...mentslWrightsoft HVACIEvan Miller Residence.rup Galc=MJ8 Front Doorfaces: E wrightsoft Right-l® Worksheet Job: Entire House Date: ay: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalea@aol.wm earn =dimensions ns Entire House 166.0 ft 9A ft 1426.0 ft' Master Bath 23.0 ft 9A ft heat/cool 1.0 • 113.0 ft 113.0 fl' Ty Construction number U-value (Btuh/fR°F I Or HTM (BtuNftO Area (ft') or perimeter (ft) Load (Btuh) Area (fP) or perimeter (it) Load (Btuh) Heat I Cool Gross I N/P/S I Heat I Cool I Grass I N/P/S Heat Cool 1 6 11 13A-4ocs 4A5-2am _4A5,;2om 13A-4ocs 4A5-2am 11DO 0.770 0.770 0.143 n n _o 1.56 2156 _2100 1.56 21.56 10.92, 4.00 �21.56 4.00 11.76 10.92 _7.59 9.31 19.31 12.19 388 5 15 344 0 0 762 1162 _394 1970 970 1438 145 290 290' 0 0 0 0 0 0 0 0 0 0 0 _0 � 0.770 0.770 0_390 a a a 2.26 3126 _10.34 2.19 19.31 2.19 25.04 10.34 445 45 �,20 367 8 414 20 19 __1426 1426 351 51 20223 359 407 7407 _211 - 786 0 0 0 66 8 0 0 0 0 0 0 0 0 yy!! G 13A-4ocs 4A5-2am 13A-40cs 10D4 11DO 0.143 —0.770 s _s_ w w w = 58 '233 __�,162 602 0 _,,,R__0 779 637 �0 128 —145 329 0 �,_0. 55 0 ley 0.143 0.420 0.390 Y,_0.408 0.989 .415 374 2 19 a��1426 166 ,_162 1497 240 �210 .,v�2261. 4597 __145 818 511 �_ 199 ,,,�_7951 0 150 0 0 —6 150 0 0 ,C� F .16X79 Omd 22A-tpl _ 1.37. —113 113 11 23 27.69 0.00 6 c) AED a— on 0 -15 Envelope loss/gain 14855 7976 1813 747 12 a) Inflbafon b) Room ventilation 3094 0 B47 0 1 429 0 117 0 13 Internal gains: Occupants@ 230 Appliances/other 101 1 2300 4300 01 0 0 Subtotal (lines 6 to 13) 17949 154231 1 1 2242 858 14 15 Less external load -less transfer — Redisbibution Subtotal Duel loads 13% 10% 0 0 0 17949 2368 0 0 0 15423 1604 13% L2242 0 0 0 858 89 X arequired (in) I I I 20�60I 17800I I I 2100I 945I Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed -rw 2019-Apr-1810:37:55 Right -Suite® Universal 201919.0.01 RSU08101 Pagel ...mentsWightsolt WAC1Evan Miller Residence.rup Cale =MJ8 Front Door faces: E + wrightsoft Right -A) Worksheet Job: Entire House Date: Quick Calcs, Inc. By: • 317 St. Lurie Lane. Fort Pierce. FL 34M Phone: 772466-6799 Email: quickcalcs@aoLcom 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Roam area Closet 11.0 ft 9.4 ft heat/cool 5.0 X 11.0 it 55.0 fP Master Bedroom 31.0 it 9.4 It heat/mot 1.0 X 245.0 ft 245.0 fit° TY Construction number U-value (Btuh/ftz°F Or I HFM (etuh/ft� I Area (f t') or perimeter (ft) I Load (Btuh) I Area (fit') of perimeter (ft) I Load (Stuh) Heat I Cool Gross N/P/S Heal Cool Gross I N/P/S Heat I Cool - T 1 T I 8 11 vj2 �L�C` 13A40M 4A5-20M 465:20m_ 13A-4aa 4A5-2om 11D0 13A4o s 4A5-tom 0.143 0.770 ^0.770 0.143 0.770 0.390 0.143 .,_____0.770 n n _o_ a a _a s ._s_ w w w = 4.00 21.56 21.56 4.00 21.56 10.92 4.00 -21.56. 4.00 11.76 10.92 _7.59 27.69 2.19 19.31 �19.31 2.19 31.26 10.34 2:19 -19.31 2.19 25.04 10.34 �1.3Z 0.00 0 0 0 0 0 0 0 0 0 0 0 -- 0 0 0 0 0 0_ 0 0 0 __ -- 0 0 0 0 0 0 103 -0 0 0 _0 103 ___0 0 0 0 55 11 -------0 0 0 0 414 __0 0 0 0 132 15 0 150 -0 117 9 0 150 0 467 323 0 255 469 0 0 , 22 yy/1 � G 4y 226 _____,__0 602 13A4ocs 10D4 11D0 -0mtl .16X790.408 22A4pl 0.143 0.420 _0.390 0.989 0 0 0 �55 55 0 0 0 0 0 0 __75 0 9 0 _0 245 245 9 0 0 -245 31 -0 38 0 0 __0 21 0 0 __335 0 ,C_ F 87 305 388 858 61 0) AED excursion .e -57 Envelope loss/gain 806 295 2877 1358 12 a) Infiltration b) Room ventilation 205 0 56 0 578 0 158 0 13 Internal gains: Occupants 230 Appliances/other 0 0 0 2 460 900 Subtotal (ines 6 to 13) 1011 351 1 3255 2876 14 15 Less external load Less lrensfe� Redistribution Subtotal Duct loads 13% 10% 0 0 0 1011 133 0 0 0 351 37 13% 10% 0 0 0 3255 429 0 0 0 2876 299 LI Air rTotae9 fired (oho) I I I 11�I 388I I I 3145 1753149I _ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed #k• wrl9tiofC 2019-Apr-1810:37:55 / A � Right -Suite® e.rup Universal Doorfa s Page2 ...menu\Wrighlsofl HVAC\Evan Miller Residence.mp CaIc=MJB Front Door races: E wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lurie Lane. Fort Pierce. FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Pantry 0 ft 9.4 ft heat/cool 4.0 x 4.0 ft 16.0 ft- Laundry 16.0 ft 9.4 ft heat/000l 10.0 x 6.0 ft 60.0 fl' Ty Construction number U-value (Bluh/ftx°F I Or HTM (Btuh/ft9 Area (ft2) I or perimeter (ft) Load I (Btuh) Area (ft.) I or perimeter (ft) Load I (Btuh) Hea( Cool Gross WP/S Heal Cool Gross NIP/S Heat Cool 6 11 VI/ II--GG 13A-00cs 4/S20M 4Ag20m 13A.4ocs 4AS2om 71 DO 13A-0acs 4A5-2om 13A4ocs 10D-f 11D0 X19- 160mtl 22A-tpl 0.143 0.770 _0.770 0.143 0.770 0,390 0.143 _0.770 0.143 0.420 0.390 -0.408 0.989 n n _n_ a a a s vs_ w w v 4.00 21.56 �21.56 4.00 21.56 10.92 4.00 _._.21.56 4.00 11.76 19.92 _1.59, 2.19 19.31 - 19.31 2.19 3126 �70.34 2.19 -19.31 2.19 25.04 10.34 _1.37 0 0 0 0 0 0 0 0 0 0 0 56 0 0 56 0 0 226 0 0 123 0 0 0 0 0 0 0 0 0 0 0 _0 0 0 0 0 0 0 0 0 0 -0 0 0 0 _ 0 0 0 �- -'0 T_0 l41 I-G 0 ______0 0 __0 0 _.,_,0 0 -0 0 -0 0 0 0 0 0 0 0 25 0 0 0 22 94 0 19 75 0 19 � �60 299 0 210 -95 164 0 199 �82 0 '-9 - C_ F -0 -16 -0 16 _80 27.69 0.00 18 0 0 0 60 16 443 61 c) AED excursion 1 0 -Y0 Envelope loss/gain 25 22 7274 548 12 a) Infiltration b) Room ventilation 0 0 6 0 298 0 82 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 0 0 500 Subtotal Dines fi to 73) 25 22 1572 1130 14 15 Less external load Less transfer Redistribution Subtotal Ducl ds 13% 10% 0 0 0 25 3 9 0 0 22 2 13% 10% 0 0 0 1572 207 0 0 0 1130 117 oa TotaLI Air required(efm) I I I 21I 21I I I 1770I 7259I Calculations aooroved by ACCA to meet all requirements of Manual J Sth Ed wrr!1�ft.`oTC 201 9-Apr-1 8 10:37:55 Right-Sulle® Universal 201919.0.01 RSU08101 ...menlsWightsoft HVACEvan Miller Residence.mp Calc=MJ8 Front Door faces: E Page3 '+}+ wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wail Room height Room dimensions Room area Kitchen 0 ft 9.4 ft hea0cool 1.0 x 104.0 ft 104.0 ft' Dining 4o ft 9.4 ft heat/cool 11.0 x 11.0 ft 121.0 ft' �I Ty Construction number U-value (Btuh/f11-F Or I HiM (BtTft� I Area (ft') or perimeter (ft) I Load (Btuh) I Area (ft.) or perimeter (ft) I Load (Btuh) Heal Cool Gross NIP/S 1 Heat Cool Gross NIP/S Heal Cool 6 11 W I��G _ _ 13A 40cs 4AS2om 4AS2om 13A-4acs 4A5-2om 11D0 13A-40cs 4A5-2am 13A4oce 10D-f 11D0 J 1970mtl 22A-tpl 0.143 0.770 _-„_-0.770 0.143 0.770 0390 n n _n_ a a e_ 4.00 21.56 _21.55. 4.00 21.56 10.92 4.00 ,21.56 4.00 11.76 10.92 _1.59, 27.69 2.19 19.31 19.31. 2.19 31.26 70.34 2.19 _19.31 2.19 25.04 10.34 -.1.37. 0.00 0---0 0 _,_0 0 0 0 0 0 0 0 0 0 0 i 0 0 0 0 0 0 0 0 0 0. 0 0 G tD _0 0 0 0 __0 0 0 0 0 0 0 -0 0 0 0 0 0 0 __o 0 0 0 y4�/1 `G 0.143 _0.770 0.143 0.420 0.390 _0.408 0.989 s _s_ w w w _ 0 -0 0 0 0-- 104 104 0 0 0 -0 -0-0-0-0 - 0 0 0 0 y/ 0 0 0 .104 0 0 0 0 ^165 0 __0 0 0 0 _142 0 38 20 0 ^121 121 17 1 _ _0 121. 4 69 240 0 ,-._792 ill _..-0. 38 511 0 _166 0 _ .C_ F 61 c) AED excursion 461 1 1 249 Envelope losstgain 165 97 1 617 964 12 a) Infiltration b) Room ventilation 0 0 0 0 75 0 20 0 13 Internal gains: Occupants @ 230 Appliances/other 2 1 460 2000 2 460 0 Subtotal Qines 6 to 13) 165 2557 686 1444 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 13% 10% 0 0 0 165 22 0 0 0 2557 266 13% 10% 0 0 4 690 91 0 -0 3 14 77 751 L I Autrequired(chn) I I I 187I 2133I I I 738111 1s75I Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed _- wr19!'•��, 2019-Apr-1810:37:55 Right-3uiteG Universal 201919.0.01 RSU08101 ' ...ments\Wrightsoft HVAC\Evan Miller Residence.rup Calc=MJS Front Doorfaces: E Page 4 L F wrightsoft• Right-J RO Worksheet Job: Entire House Date: sy: Quick Calcs, Inc. 317 St. Lucie Lane. Fort Pierce. FL 34946 Phone: 772-466-6799 Email: quickniw@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bedroom 3 32.0 R 9.4 R heat/ceol 13.0 X 14.0 ft 182.0 ft- Bathroom 6.0 ft 9.4 R heat/cool 9.0 x 6.0 R 54.0 ft' Ty Construction number U-value (Btuh/ft 1 Or HTM I (Btuh/fl- Area (fP) I or perimeter (R) Lead I (Bmh) Area UP) I or perimeter (R) Load I (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool T 6 11 vII�--� �-G 13A-tom 4A5-tom ,4S2om 13AAocs 4AS-2cm 11DO 13A-40cs 4A5-2om. 13A-4ocs 10D-f 11D0 78X79;Ome 22A-Ipl 0.143 0.770 _0.770 0.143 0.770 __g390 0.143 -0.770 0.143 0.420 0.390 �0.408 0.989 n n _n_ a a a s _s_ w w w_ - 4.56 21.56 _21.56 4.00 21.56 _70.92 4.00 _21.56 4.00 11.76 10.92 _1.59 27.69 9.31 19.31 _79,31 2.19 31.26 _10.34 2.19 _19.31 2.19 25.04 10.34 _1.37 132 0 777 0 0 460 0 _ 323 -_ 0 0 0 255 0 290 0 0 0 _ 58 8 0 49 0 162 162 07 145 745 �75 0 0 0 0 0 __0 47 0 0 0 -0-0 0 0 0 0 0 __0 0 0 0 LDDD- 4l�}/ 47 18ti 103 0 0 _0 i 0 �0 .�_._G Vy ��DG -0-0-0 122 0 -0 182 122 0 0 _182 489 0 0 -0-0-0-0 267 0 0 ,249 0 0 0 0 _ _ -54 54 0 0 0 0 0 0 _0 0 0 0 _74 0 .C_ F �289 __54 6 -86 166 0.00 182 32 886 61 c) AED excursion -27 -6 Envelope lossigain 2642 1137 609 319 11 12 a) In8ltmtion b) Room ventilation 596 0 163 0 112 0 31 0 13 Internal gains: Occupants@ 230 Appliances/other 1 230 0 0 0 0 Subtotal tines 6 to 13) 3239 1530 721 350 d =ta 13% 10% 0 0 8 3246 428 0 0 8 1536 160 13% 10% 0 0 11 732 97 0 0 10 360 37 Air rel qulred (ahn) I I 145I 16800I I I 82393I 399I Calculations approved by ACCA to meet all requirements of Manual J Sth Ed. 2019-Apr-1810:37:55 Right-Suile® Unive.rup sal =M.18019 .Fron Doorta s Page5 ...merits\lMighisoR HVAC\Evan Miller Residence.mp CaIc=MJB Front Door faces: E 1 wrightsoft' Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St Lucie Lane, Fort Pierce, FL 34W Phone: 772<86-6799 Email: quickcalcsQaol.com =dimehngwon. s Bedroom 2 26.0 ft 9A R heat/cool 13.0 x 13.0 R 169.0 ft2 Hall 0 ft 9.4 R heaUcool 4.0 x 6.0 ft 24.0 ft2 Ty Constmction number U-value (Btuh/fP-°F Or HTM I 2) Area (ft2) I or perimeter (ft) Load I Ohuh) Area (ft2) I or perimeter (ft) Load I (Btuh) Heal(eluh/fl Cool Grass I WP/S Heal Cool Grass I WP/S Heal Cool I I I 1 I I e 1 13A-4ono 4A5-tom ,AS2om 13A4ocs 4AS20m 11D0 13A-40cs 4AS2om 13A-4ocs tOD-f 11 DO 18XlMmd. 22Mtpl 0. 0.770 770 0,770 0.143 0.770 -0.390 0.143 -_0.7.70 0.143 0.420 n n -n_ a a _e_ s ,_s_ w w w 4D0 21.56 21.55 4.00 21.56 10.92 4.00 _21.56 4.00 11.76 10.92 =1.59. 27.69 2. 19.31 37 _79.3-1. 2.19 31.26 10.34 122 0 0 12 0 0 48 0 0 267 0 0 0 0 0 0 0 0 0 0 __ -- 0 0 -0 122 15 0 -0-0 107 9 0 429 323 0 235 469 0 0 0 0 0 0 0 0 0 0 0 0 �D _ 2.19 -19.31 2.19 25.04 10.34 =1.37 0.00 0' 0 0-0 0-0-0--0 0-- 0 0 0 0 -0-0-0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 -0 0 0 0 - F _0.390 -0.408 0.989 �, �169 169 � 16 9 26 266 720 231 0 ,_„24 24 _24 �36 ---33 0 0 0 61 c) AED excursion _27 -7 Envelope loss/gain 2230 117 38 32 12 a) Infiltration b) Rcamventilation 465 0 133 0 0 0 0 0 13 Internal gains: Occupants@ 230 Appliances/other 1 230 0 0 0 0 Subtotal (lines 6to 13) 2714 15371 1 1 38 32 14 15 Less external load - Less transfer- Redistribution Subtotal Duct loads 13% 10% 0 0 8 2722 359 0 0 6 1544 161 1 13% 1 10% 0 0 -38 0 0 0 0 -32 0 0 AiI n) I I 1 312I 17o�( 80I I I OI Ita 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed F wn Right -Suite® Universal 201919.0.01 RSU08101 2019-Apr-181 Page6 ...mentsXANghtsoft HVACIEvan Miller Residence.rup Calc=MJS Front Door faces: E wrightscift Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St Lurie Lane. Fort Pierce. FL 34946 Phone: 77246"799 Email: quicAcalcs@aol.mm 1 2 3 4 5 Room name Exposed wall 1 Room height Room dimensions Room area Great Room 17.0 ft 9.4 it heat(cool 1.0 x 283.0 it 263.0 it Ty Construction number U-value (Bluh/ft"F Or HIM I (Btuh/ft0 Area ifP) I or perimeter (it) Load I (Btuh) Area I or perimeter Load Heal Cool Gross WP/S Heat Cool Gross I N/P/S Heal Cool 6 11 H—G �G 13A-4ocs 4A5-2om 4A5-2om 13A4ocs 4A5-tom 11D0_ 13AAocs 4A5-tom 13A-4ocs 10Pf 1100 -16X79-0md 0.143 0.770 0:770 0.143 0.770 _ 0390 0.143 —0.770 0.143 0.420 _,_0.390 _0.408 0.989 n n _n_ a a e_ s _s_ w w w 4.00 21.56 _21,56 4.00 21.56 10.92 4.00 2.19 19.31 _19.31 2.19 31.26 10.34 2.19 0 0 0 0 0 0 0 0 0 0 1� I--G 160 15 -0 124 9 __ 20 0 -0 498 323 223 0 272 469 _211 0 Yy��ll _20 0 Vl/ LL_pG _21,56. 4.00 11.76 10.92 __1.59_ _19.31 2.19 26.04 10.34 �1.37, —0-0-0-0 0 0 _ 0 _283 0 0 _ _0 �283 0 0 0 449 471 0 0 0 —387 0 _ C_ F _ 22A-lpl _ 27.69 0.00 _283 17 _ 6 c) AED excursion 49 Envelope la5a/galn 1964 1290 12 a) Infiltration b) Roam ventilation 317 0 87 0 13 Internal gains: Occupants® 230 Appliances/other 2 460 900 Subtotal (lines 6 to 13) 2281 2737 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 13% 10% 0 0 8 2288 302 0 0 6 2743 285 1 or Atae= a,1 1 1 1 2199001 3019 1 1 1 1 Calculations aooroved by ACCA to meet all reouirements of Manual J 8th Ed *4- It. ofC 2019-Apr-1810:37:55 RlghtSuile® Universal 201919.0.01 RSU08101 page ...menls\Wrightsoft HVA(AEvan Miller Residence.mp Cale =MJ8 Front Door faces: E Duct S stem Summa Job: wrightsoft' Y � Date: Entire House BY: Quick Calcs, Inc. 317 St. Lucia Lane, Fort Pierce, FL 34W Phone: 772AG"799 Email: quickcelce@aol.com Project• • For: Evan Miller 5437 Ideal Holding Road, Fort Pierce, FL 34987 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest.friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.261 in/100ft 800 cfm 192 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.261 in/100ft 800 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bathroom h 829 33 19 0.267 5.0 OxO VIFx 32.5 155.0 st4 Bedroom 2 h 3081 121 80 0.266 7.0 Ox 0 VIFX 33.2 155.0 st4 Bedroom 3 h 3675 145 80 0.261 7.0 Ox 0 VIFx 36.9 155.0 st4 Closet h 1144 45 18 0.387 5.0 Ox 0 VIFx 14.2 115.0 st2 Dining c 1598 31 75 0.322 6.0 Ox 0 VIFx 20.4 135.0 st3 Great Room c 3029 102 142 0.314 7.0 Ox0 VIFx 24.1 135.0 st3 Kitchen c 2823 7 133 0.406 7.0 Ox0 VIFX 8.1 115.0 st1 Laundry h 1779 70 59 0.398 6.0 Ox 0 VIFX 10.7 115.0 stl Master Bath h 2538 100 45 0.391 7.0 Ox0 VIFX 12.8 115.0 st2 Master Bedroom o 3175 145 149 0.363 8.0 Ox0 VIFX 22.8 115.0 St2 Pantry c 29 1 1 0.401 4.0 Ox 0 I VIFx 1 9.6 115.0 stl Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 299 178 0.261 548 10.0 0 x 0 VinlFlx st3 st3 Peak AVF 431 396 0.261 549 12.0 0 x 0 VinlFlx sit st1 Peak AVF 510 588 0.261 550 14.0 0 x 0 VinlFix st2 Peak AVF 290 212 0.363 532 10.0 0 x 0 VinlFlx C - wrtghtsofC 2019-Apr-1810:37:55 r-�..d... RlghtSuite® Universal 201919.0.01 RSU08101 Pagel ^��v...mentsXMghtsoft WACIEvan Miller Residence.rup Calc=MJB Fmnt Doorfaces:E