HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE COPY
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
/ Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Evan Miller Residence
Builder Name:
SCANNED
5437 Ideal Holding Road
Permit Office: St. Lucie County
BY
City, Stale, Zip: Fort Pierce , FL, 34987
Permit Number:
Owner: Evan Miller
Jurisdiction: St. Lucie County
St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1563.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1563.20 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1426.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1426.00 ft2
6. Conditioned floor area above grade (ft2) 1426
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(95.5 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
a. U-Factor. Dbl, U=0.65 75.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 20.50 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.283 ft.
Area Weighted Average SHGC: 0.261
14. Hot water systems
8. Floor Types (1426.0 sqft.) Insulation Area
a. Propane Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1426.00 ft2
b. Conservation features
EF: 0.600
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.067 Total Proposed Modified Loads: 49.14
PASS
Total Baseline Loads: 51.58
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
p,THESptl�
�S'
Code.
calculation indicates compliance
with the Florida Energy Code.
rnxr`•.: {;;i�,;:x°„ �O
PREPARED Y:
Before construction is completed
:4F
DATE: ''
this building will be inspected for
compliance with Section 553.908
8
�.
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy ode.
C'0 WE
OWNER/AGE T:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
bertified-factory-sealed in accordance with R403.3.2.1.
A - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
RECEIVED
4/18/2019 10:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Softwar MAY 9 12019 age 1 of 5
Si. Lucie County, Permitting
ti
FORM R465-2D17 INPUT SUMMARY CHECKLIST KEPUKI
PROJECT
Title: Evan Miller Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1426
Lot #
Owner Name: Evan Miller
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
5437 Ideal Holding Roa
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34987
New/Fxisting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1426 13404.4
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Healed
1 Master Bath
113 1062.2 No
0
1
Yes
Yes
Yes
2 Closet
55 517 No
0
1
Yes
Yes
Yes
3 Master Bedroom
245 2303 No
2
1
1
Yes
Yes
Yes
4 Pantry
16 150.4 No
0
1
No
Yes
Yes
5 Laundry
60 564 No
0
1
Yes
Yes
Yes
6 Kitchen
104 977.6 Yes
2
1
No
Yes
Yes
7 Dining
121 1137.4 No
2
1
Yes
Yes
Yes
8 Bedroom 3
182 1710.8 No
1
1
1
Yes
Yes
Yes
9 Bathroom
64 507.6 No
0
1
Yes
Yes
Yes
10 Bedroom 2
169 1588.6 No
1
1
1
Yes
Yes
Yes
11 Hall
24 225.6 No
0
1
No
Yes
Yes
12 Great Room
283 2660.2 No
2
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpel
1 Slab -On -Grade Edge Insulatio
Master Bath 23 It 0
113 ft'
_
1 0
0
2 Slab -On -Grade Edge Insulatio
Closet lift 0
551t,
_
1 0
0
3 Slab -On -Grade Edge Insulatio
Master Bedroom 31 ft 0
245 ft'
_
1 0
0
4-Slab-On-Grade Edge Insulatio
Pantry 1 it 0
16 ft'
_
1 0
0
15 Slab -On -Grade Edge Insulatio
Laundry 16 ft 0
60 It,
—
1 0
0
4/18/2019 10:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5
t
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
w
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
Kitchen 1 It
0
104 ft2
—
1
0
0
7 Slab -On -Grade Edge Insulatio
Dining 4 It
0
121 ft2
_
1
0
0
8 Slab -On -Grade Edge Insulatio
Bedroom 3 32 ft
0
182 112
_
1
0
0
9 Slab -On -Grade Edge Insulatio
Bathroom 6 ft
0
54 ft2
_
1
0
0
10SIab-On-Grade Edge Insulatio
Bedroom 2 26 It
0
169 ft2
—
1
0
0
11Slab-On-Grade Edge Insulatio
Hall 1 It
0
24 ft2
—
1
0
0
12SIab-On-Grade Edge Insulatio
Great Room 17 ft
0
283 ft2
—
1
0
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials
Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 1595 ft2
0 ft2
Light
0.6
No
0.9
No
20
26.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1426 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented)
Master Bath
20
Blown
113 ft2
0.1
Wood
2 Under Attic (Unvented)
Closet
20
Blown
55 ft2
0.1
Wood
3 Under Attic (Unvented)
Master Bedroom
20
Blown
245 ft-
0.1
Wood
4 Under Attic (Unvented)
Pantry
20
Blown
16 ft2
0.1
Wood
5 Under Attic (Unvented)
Laundry
20
Blown
60 ft2
0.1
Wood
6 Under Attic (Unvented)
Kitchen
20
Blown
104 ft2
0.1
Wood
7 Under Attic (Unvented)
Dining
20
Blown
121 ft2
0.1
Wood
8 Under Attic (Unvented)
Bedroom 3
20
Blown
182 ft2
0.1
Wood
9 Under Attic (Unvented)
Bathroom
20
Blown
54 ft2
0.1
Wood
10 Under Attic (Unvented)
Bedroom 2
20
Blown
169 ft2
0.1
Wood
_
11 Under Attic (Unvented)
Hall
20
Blown
24 ft2
0.1
Wood
12 Under Attic (Unvented)
Great Room
20
Blown
283 112
0.1
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing
Solar
Below
_ 1
S Exterior Concrete Block - Ext InsMaster Bath
4.1 7
0 9
5
65.9 ft2
0
0
0.6
0
_ 2
W Exterior Concrete Block - Ext InsMaster Bath
4.1 16
0 9
5
150.7 ft2
0
0
0.6
0
_ 3
S Exterior Concrete Block - Ext Insul Closet
4.1 11
0 9
5
103.6 ft2
0
0
0.6
0
4
E Exterior Concrete Block - Ext InNtister Bedro
4.1 14
0 9
5
131.8 ft2
0
0
0.6
0
4118/2019 10:32 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Below
Space
_ 5
S
Exterior
Concrete Block - Ext InMhster Bedro
4.1
16
0
9 5
150.7 ft'
0
0
0.6
0
-6
W
Exterior
Concrete Block - Ed Inddlister Bedro
4.1
1
0
9 5
9.4 ft'
0
0
0.6
0
-7
N
Exterior
Concrete Block- Ext Insul Laundry
4.1
6
0
9 5
56.5 ft'
0
0
0.6
0
_ 8
W
Exterior
Concrete Black - Ext Insul Laundry
4.1
10
0
9 5
94.2 ft'
0
0
0.6
0
-9
W
Exterior
Concrete Block - Ext Insul Dining
4.1
4
0
9 5
37.7 ft'
0
0
0.6
0
10
N
Exterior
Concrete Black - Ext Insd3edroom 3
4.1
14
0
9 5
131.8 ft2
0
0
0.6
0
_ 11
S
Exterior
Concrete Block - Ext Insdiledroom 3
4.1
5
0
9 5
47.1 ft'
0
0
0.6
0
_ 12
W
Exterior
Concrete Block- Ext InsiBedroom 3
4.1
13
0
9 5
122.4 ft'
0
0
0.6
0
_ 13
N
Exterior
Concrete Block- Ext InsuBalhroom
4.1
6
0
9 5
56.5 ft'
0
0
0.6
0
_ 14
N
Exterior
Concrete Block - Ext InsiBedroom 2
4.1
13
0
9 5
122.4 ft'
0
0
0.6
0
_ 15
E
Exterior
Concrete Block - Ext InsxBedroom 2
4.1
13
0
9 5
122A ft2
0
0
0.6
0
16
E
Exterior
Concrete Block - Ext Ins(Hreat Room
4.1
17
0
9 5
160.1 ft2
0
0
0.6
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Wood Laundry
None
.39
2
10
6 10
19.4 ft'
2
E
Wood Great Room
None
.39
3
6 10
20.5 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S 1
Metal Low-E Double Yes
0.65
0.25
N
7.5 ft'
1 It 7 in
1 ft 4 in
None
None
2
E 4
Metal Low-E Double Yes
0.65
0.25
N
15.0 ft'
5 ft 0 in
1 It 4 in
None
None
3
W 9
Wood Low-E Double Yes
0.65
0.3
N
20.5 ft'
2 ft 0 in
1 ft 4 in
None
None
4
N 10
Metal Low-E Double Yes
0.65
0.25
N
15.0 ft'
1 It 7 in
1 ft 4 in
None
None
5
N 13
Metal Low-E Double Yes
0.65
0.25
N
7.5 ft'
1 It 7 in
1 ft 4In
None
None
_
6
E 15
Metal Low-E Double Yes
0.65
0.25
N
15.0 ft'
5 It 0 in
1 ft 4 in
None
None
7
E 16
Metal Low-E Double Yes
0.66
0.25
N
15.0 ft2
5 ft 0 in
1 It 4 in
None
None
INFILTRATION
# Scope
Method SLA CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000418 1563.8
85.85
161.46
.318
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COPA
17 kBtu/hr
1
sys#1
S
4/18/2019 10:32 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
f
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 16
24 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF
Cap
Use
SetPnt
Conservation
1 Propane
Tankless
Exterior
0.6
1 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
/ -- Supply —
— Return—
At
CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 120 ft-
Attic
30 ft'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable T]hermosta�[t:]]Y
Gelling Fans:
Heating [X] Jan Feb
[[ ]]
pC] Mar
Apr
Mexl
May
Jun
AugJul�rX�iX
i
rr
Nov
Nov
Dec
Venting [[ l) Jan [I )1 Feb
l l
[[fix]) Mar
[
lApr
Jun lxl Jul
[ Aug
[ Sep
[X� Oct X
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78 80
80
80
80
PM
80
80 78
78
78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78 78
78
78
78
PM
78
78 78
78
78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66
66 68
68
68 68
68
68
68
PM
68
68 68
68
68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66
66 68
68
68 68
68
68
68
PM
68
68 68
68
68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft-
0 ft
0.3
Master Bath
Default(8 lbs/sq.ft.
ft'
ft
0.3
Closet
Default(8 lbs/sq.fL
ft'
ft
0.3
Master Bedroom
Default(8 lbs/sq.ft.
ft'
ft
0.3
Pantry
Default(8 lbs/sq.ft.
ft'
ft
0.3
Laundry
Default(8 lbs/sq.ft.
ft'
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft'
ft
0.3
Dining
Default(8 lbs/sq.ft.
ft
ft
0.3
Bedroom 3
Default(8 lbs/sq.ft.
ft'
ft
0.3
Bathroom
Defaull(8-Ibs/sq.ft.
ft'
ft
0.3
Bedroom
Default(8 lbslsq.ft.
ft'
ft
0.3
Hall
Default 8lbsls A.
ft'
ft
0.3
Great Room
Name: Signature:
4/18/2019Pr@.VpA'om(lant: EnergyGauge® USA Section tQ#3.qil UnopllwtS^tbver^ 4—` :�s Page 9 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Evan Miller Residence Builder Name:
Street: 6437 Ideal Holding Road Permit Office: St. Lucie County
City, Stale, Zip: Fort Pierce, FL, 34987 Permit Number.
Owner: Evan Miller Jurisdiction: St. Lucie County
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
y pp 9 /soffit
the Insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air border.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall,
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninina and Wrina
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be Installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. hi ahhlmon, Inspecuvu ui luy waiiu shall be In accomance win me provisions Or 1GG-4UU.
4/18/2019 10:32 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
+
+ 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Att c
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
24.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1426
d) Room uniUPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.261
14. Heating system: Capacity
17.0
c) Area
7c.
95.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
0.60
A. Exterior.
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a.
20.0
b) Cross ventilation
No
b) Single assembly
11b,
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: 30 /
Address of New Home: _ 5437 Ideal Holding Road City/FL Zip: Fort Pierce, FL 34987
4/18/2019 10:32:44 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Project Summary Job:
wrightsoft' Entire House Byte.
Quick Calcs, Inc.
= 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickm1m@aol.com
Promect Information
For: Evan Miller
5437 Ideal Holding Road, Fort Pierce, FL 34987
Notes:
Design
Information
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Structure
17949
Btuh
Ducts
2368
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
20316
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Heatin
Co1426
Area (ftJ
1426
Volume
13404
13404
Air changes/hour
0.45
0.23
Equiv. AVF (dm)
101
51
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
-Airflow-factor
Static pressure
Space thermostat
Sensible Cooling Equipment Load Sizing
Structure
15423
Btuh
Duds
1604
Btuh
Central vent (0 dm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
16176
Btuh
Latent Cooling Equipment Load Sizing
Structure
4146
Btuh
Duds
1223
Btuh
Central vent (0 dm)
0
Btuh
(none)
Equipment latent load
5370
Btuh
Equipment Total Load (Sen+Lat)
21546
Btuh
Req. total capacity at 0.70 SHR
1.9
ton
Cooling Equipment Summary
Make Trane
Trade TRANE
Cond 4TTR40251-1
Coil TEM6AOB30H21++TDR
AHRI ref 7567541
100 EFF
Efficiency
6.0
kW
Sensible cooling
20316
Btuh
Latent cooling
23
OF
Total cooling
800
dm
Actual air flow
0.039
dm/Btuh
Air flow
0.50
in H2O
Static pressure
Load sensible heat ratio
13.0 EER, 16 SEER
16800
Btuh
7200
Btuh
24000
Btuh
800
dm
0.047
dm/Btuh
0.50
in H2O
0.76
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wrlwtitsoft� 2019-Apr-1810:37:55
1-1 - -- Right-Suilc� U niversal 201919.0.01 RSU08101 Page
��...mentslWrightsoft HVACIEvan Miller Residence.rup Galc=MJ8 Front Doorfaces: E
wrightsoft Right-l® Worksheet Job:
Entire House Date:
ay:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalea@aol.wm
earn
=dimensions
ns
Entire House
166.0 ft
9A ft
1426.0 ft'
Master Bath
23.0 ft
9A ft heat/cool
1.0 • 113.0 ft
113.0 fl'
Ty
Construction
number
U-value
(Btuh/fR°F
I Or
HTM
(BtuNftO
Area (ft')
or perimeter (ft)
Load
(Btuh)
Area (fP)
or perimeter (it)
Load
(Btuh)
Heat
I Cool
Gross
I N/P/S
I Heat
I Cool
I Grass
I N/P/S
Heat
Cool
1
6
11
13A-4ocs
4A5-2am
_4A5,;2om
13A-4ocs
4A5-2am
11DO
0.770
0.770
0.143
n
n
_o
1.56
2156
_2100
1.56
21.56
10.92,
4.00
�21.56
4.00
11.76
10.92
_7.59
9.31
19.31
12.19
388
5
15
344
0
0
762
1162
_394
1970
970
1438
145
290
290'
0
0
0
0
0
0
0
0
0
0
0
_0
�
0.770
0.770
0_390
a
a
a
2.26
3126
_10.34
2.19
19.31
2.19
25.04
10.34
445
45
�,20
367
8
414
20
19
__1426
1426
351
51
20223
359
407
7407
_211
- 786
0
0
0
66
8
0
0
0
0
0
0
0
0
yy!!
G
13A-4ocs
4A5-2am
13A-40cs
10D4
11DO
0.143
—0.770
s
_s_
w
w
w
=
58
'233
__�,162
602
0
_,,,R__0
779
637
�0
128
—145
329
0
�,_0.
55
0
ley
0.143
0.420
0.390
Y,_0.408
0.989
.415
374
2
19
a��1426
166
,_162
1497
240
�210
.,v�2261.
4597
__145
818
511
�_ 199
,,,�_7951
0
150
0
0
—6
150
0
0
,C�
F
.16X79 Omd
22A-tpl
_ 1.37.
—113
113
11
23
27.69
0.00
6
c) AED a— on
0
-15
Envelope loss/gain
14855
7976
1813
747
12
a) Inflbafon
b) Room ventilation
3094
0
B47
0
1
429
0
117
0
13
Internal gains: Occupants@ 230
Appliances/other
101
1
2300
4300
01
0
0
Subtotal (lines 6 to 13)
17949
154231
1
1
2242
858
14
15
Less external load
-less transfer —
Redisbibution
Subtotal
Duel loads
13%
10%
0
0
0
17949
2368
0
0
0
15423
1604
13%
L2242
0
0
0
858
89
X arequired (in)
I
I
I 20�60I
17800I
I
I
2100I
945I
Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed
-rw 2019-Apr-1810:37:55
Right -Suite® Universal 201919.0.01 RSU08101 Pagel
...mentsWightsolt WAC1Evan Miller Residence.rup Cale =MJ8 Front Door faces: E
+ wrightsoft Right -A) Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
• 317 St. Lurie Lane. Fort Pierce. FL 34M Phone: 772466-6799 Email: quickcalcs@aoLcom
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Roam area
Closet
11.0 ft
9.4 ft heat/cool
5.0 X 11.0 it
55.0 fP
Master Bedroom
31.0 it
9.4 It heat/mot
1.0 X 245.0 ft
245.0 fit°
TY
Construction
number
U-value
(Btuh/ftz°F
Or
I HFM
(etuh/ft�
I Area (f t')
or perimeter (ft)
I Load
(Btuh)
I Area (fit')
of perimeter (ft)
I Load
(Stuh)
Heat
I Cool
Gross
N/P/S
Heal
Cool
Gross
I N/P/S
Heat
I Cool
-
T
1
T
I
8
11
vj2
�L�C`
13A40M
4A5-20M
465:20m_
13A-4aa
4A5-2om
11D0
13A4o s
4A5-tom
0.143
0.770
^0.770
0.143
0.770
0.390
0.143
.,_____0.770
n
n
_o_
a
a
_a
s
._s_
w
w
w
=
4.00
21.56
21.56
4.00
21.56
10.92
4.00
-21.56.
4.00
11.76
10.92
_7.59
27.69
2.19
19.31
�19.31
2.19
31.26
10.34
2:19
-19.31
2.19
25.04
10.34
�1.3Z
0.00
0
0
0
0
0
0
0
0
0
0
0
-- 0
0
0
0
0
0_
0
0
0
__
-- 0
0
0
0
0
0
103
-0
0
0
_0
103
___0
0
0
0
55
11
-------0
0
0
0
414
__0
0
0
0
132
15
0
150
-0
117
9
0
150
0
467
323
0
255
469
0
0
, 22
yy/1
� G
4y
226
_____,__0
602
13A4ocs
10D4
11D0
-0mtl
.16X790.408
22A4pl
0.143
0.420
_0.390
0.989
0
0
0
�55
55
0
0
0
0
0
0
__75
0
9
0
_0
245
245
9
0
0
-245
31
-0
38
0
0
__0
21
0
0
__335
0
,C_
F
87
305
388
858
61
0) AED excursion
.e
-57
Envelope loss/gain
806
295
2877
1358
12
a) Infiltration
b) Room ventilation
205
0
56
0
578
0
158
0
13
Internal gains: Occupants 230
Appliances/other
0
0
0
2
460
900
Subtotal (ines 6 to 13)
1011
351
1
3255
2876
14
15
Less external load
Less lrensfe�
Redistribution
Subtotal
Duct loads
13%
10%
0
0
0
1011
133
0
0
0
351
37
13%
10%
0
0
0
3255
429
0
0
0
2876
299
LI
Air rTotae9 fired (oho) I
I
I
11�I
388I
I
I
3145
1753149I
_ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
#k• wrl9tiofC 2019-Apr-1810:37:55
/ A � Right -Suite® e.rup Universal Doorfa s Page2
...menu\Wrighlsofl HVAC\Evan Miller Residence.mp CaIc=MJB Front Door races: E
wrightsoft• Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lurie Lane. Fort Pierce. FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Pantry
0 ft
9.4 ft heat/cool
4.0 x 4.0 ft
16.0 ft-
Laundry
16.0 ft
9.4 ft heat/000l
10.0 x 6.0 ft
60.0 fl'
Ty
Construction
number
U-value
(Bluh/ftx°F
I Or
HTM
(Btuh/ft9
Area (ft2)
I or perimeter (ft)
Load
I (Btuh)
Area (ft.)
I or perimeter (ft)
Load
I (Btuh)
Hea(
Cool
Gross
WP/S
Heal
Cool
Gross
NIP/S
Heat
Cool
6
11
VI/
II--GG
13A-00cs
4/S20M
4Ag20m
13A.4ocs
4AS2om
71 DO
13A-0acs
4A5-2om
13A4ocs
10D-f
11D0
X19-
160mtl
22A-tpl
0.143
0.770
_0.770
0.143
0.770
0,390
0.143
_0.770
0.143
0.420
0.390
-0.408
0.989
n
n
_n_
a
a
a
s
vs_
w
w
v
4.00
21.56
�21.56
4.00
21.56
10.92
4.00
_._.21.56
4.00
11.76
19.92
_1.59,
2.19
19.31
- 19.31
2.19
3126
�70.34
2.19
-19.31
2.19
25.04
10.34
_1.37
0
0
0
0
0
0
0
0
0
0
0
56
0
0
56
0
0
226
0
0
123
0
0
0
0
0
0
0
0
0
0
0
_0
0
0
0
0
0
0
0
0
0
-0
0
0
0
_ 0
0
0
�- -'0
T_0
l41
I-G
0
______0
0
__0
0
_.,_,0
0
-0
0
-0
0
0
0
0
0
0
0
25
0
0
0
22
94
0
19
75
0
19
� �60
299
0
210
-95
164
0
199
�82
0
'-9 -
C_
F
-0
-16
-0
16
_80
27.69
0.00
18
0
0
0
60
16
443
61
c) AED excursion
1
0
-Y0
Envelope loss/gain
25
22
7274
548
12
a) Infiltration
b) Room ventilation
0
0
6
0
298
0
82
0
13
Internal gains: Occupants@ 230
Appliances/other
0
0
0
0
0
500
Subtotal Dines fi to 73)
25
22
1572
1130
14
15
Less external load
Less transfer
Redistribution
Subtotal
Ducl ds
13%
10%
0
0
0
25
3
9
0
0
22
2
13%
10%
0
0
0
1572
207
0
0
0
1130
117
oa
TotaLI Air required(efm) I
I
I
21I
21I
I
I
1770I
7259I
Calculations aooroved by ACCA to meet all requirements of Manual J Sth Ed
wrr!1�ft.`oTC 201 9-Apr-1 8 10:37:55
Right-Sulle® Universal 201919.0.01 RSU08101
...menlsWightsoft HVACEvan Miller Residence.mp Calc=MJ8 Front Door faces: E Page3
'+}+ wrightsoft• Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com
1
2
3
4
5
Room name
Exposed wail
Room height
Room dimensions
Room area
Kitchen
0 ft
9.4 ft hea0cool
1.0 x 104.0 ft
104.0 ft'
Dining
4o ft
9.4 ft heat/cool
11.0 x 11.0 ft
121.0 ft'
�I
Ty
Construction
number
U-value
(Btuh/f11-F
Or
I HiM
(BtTft�
I Area (ft')
or perimeter (ft)
I Load
(Btuh)
I Area (ft.)
or perimeter (ft)
I Load
(Btuh)
Heal
Cool
Gross
NIP/S
1 Heat
Cool
Gross
NIP/S
Heal
Cool
6
11
W
I��G
_ _
13A 40cs
4AS2om
4AS2om
13A-4acs
4A5-2om
11D0
13A-40cs
4A5-2am
13A4oce
10D-f
11D0
J 1970mtl
22A-tpl
0.143
0.770
_-„_-0.770
0.143
0.770
0390
n
n
_n_
a
a
e_
4.00
21.56
_21.55.
4.00
21.56
10.92
4.00
,21.56
4.00
11.76
10.92
_1.59,
27.69
2.19
19.31
19.31.
2.19
31.26
70.34
2.19
_19.31
2.19
25.04
10.34
-.1.37.
0.00
0---0
0
_,_0
0
0
0
0
0
0
0
0
0
0
i 0
0
0
0
0
0
0
0
0
0.
0
0
G
tD
_0
0
0
0
__0
0
0
0
0
0
0
-0
0
0
0
0
0
0
__o
0
0
0
y4�/1
`G
0.143
_0.770
0.143
0.420
0.390
_0.408
0.989
s
_s_
w
w
w
_
0
-0
0
0
0--
104
104
0
0
0
-0
-0-0-0-0
- 0
0
0
0
y/
0
0
0
.104
0
0
0
0
^165
0
__0
0
0
0
_142
0
38
20
0
^121
121
17
1
_ _0
121.
4
69
240
0
,-._792
ill
_..-0.
38
511
0
_166
0
_
.C_
F
61
c) AED excursion
461
1
1
249
Envelope losstgain
165
97
1
617
964
12
a) Infiltration
b) Room ventilation
0
0
0
0
75
0
20
0
13
Internal gains: Occupants @ 230
Appliances/other
2
1
460
2000
2
460
0
Subtotal Qines 6 to 13)
165
2557
686
1444
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
13%
10%
0
0
0
165
22
0
0
0
2557
266
13%
10%
0
0
4
690
91
0
-0
3
14 77
751
L I
Autrequired(chn) I
I
I
187I
2133I
I
I
738111
1s75I
Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed
_- wr19!'•��, 2019-Apr-1810:37:55
Right-3uiteG Universal 201919.0.01 RSU08101 ' ...ments\Wrightsoft HVAC\Evan Miller Residence.rup Calc=MJS Front Doorfaces: E Page 4
L
F wrightsoft• Right-J RO Worksheet Job:
Entire House Date:
sy:
Quick Calcs, Inc.
317 St. Lucie Lane. Fort Pierce. FL 34946 Phone: 772-466-6799 Email: quickniw@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Bedroom 3
32.0 R
9.4 R heat/ceol
13.0 X 14.0 ft
182.0 ft-
Bathroom
6.0 ft
9.4 R heat/cool
9.0 x 6.0 R
54.0 ft'
Ty
Construction
number
U-value
(Btuh/ft 1
Or
HTM
I (Btuh/fl-
Area (fP)
I or perimeter (R)
Lead
I (Bmh)
Area UP)
I or perimeter (R)
Load
I (Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
T
6
11
vII�--�
�-G
13A-tom
4A5-tom
,4S2om
13AAocs
4AS-2cm
11DO
13A-40cs
4A5-2om.
13A-4ocs
10D-f
11D0
78X79;Ome
22A-Ipl
0.143
0.770
_0.770
0.143
0.770
__g390
0.143
-0.770
0.143
0.420
0.390
�0.408
0.989
n
n
_n_
a
a
a
s
_s_
w
w
w_
-
4.56
21.56
_21.56
4.00
21.56
_70.92
4.00
_21.56
4.00
11.76
10.92
_1.59
27.69
9.31
19.31
_79,31
2.19
31.26
_10.34
2.19
_19.31
2.19
25.04
10.34
_1.37
132
0
777
0
0
460
0
_ 323
-_ 0
0
0
255
0
290
0
0
0
_
58
8
0
49
0
162
162
07
145
745
�75
0
0
0
0
0
__0
47
0
0
0
-0-0
0
0
0
0
0
__0
0
0
0
LDDD-
4l�}/
47
18ti
103
0
0
_0
i 0
�0
.�_._G
Vy
��DG
-0-0-0
122
0
-0
182
122
0
0
_182
489
0
0
-0-0-0-0
267
0
0
,249
0
0
0
0
_ _ -54
54
0
0
0
0
0
0
_0
0
0
0
_74
0
.C_
F
�289
__54
6
-86
166
0.00
182
32
886
61
c) AED excursion
-27
-6
Envelope lossigain
2642
1137
609
319 11
12
a) In8ltmtion
b) Room ventilation
596
0
163
0
112
0
31
0
13
Internal gains: Occupants@ 230
Appliances/other
1
230
0
0
0
0
Subtotal tines 6 to 13)
3239
1530
721
350
d
=ta
13%
10%
0
0
8
3246
428
0
0
8
1536
160
13%
10%
0
0
11
732
97
0
0
10
360
37
Air rel qulred (ahn)
I
I
145I
16800I
I
I
82393I
399I
Calculations approved by ACCA to meet all requirements of Manual J Sth Ed.
2019-Apr-1810:37:55
Right-Suile® Unive.rup sal =M.18019 .Fron Doorta s Page5
...merits\lMighisoR HVAC\Evan Miller Residence.mp CaIc=MJB Front Door faces: E
1
wrightsoft' Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St Lucie Lane, Fort Pierce, FL 34W Phone: 772<86-6799 Email: quickcalcsQaol.com
=dimehngwon.
s
Bedroom 2
26.0 ft
9A R heat/cool
13.0 x 13.0 R
169.0 ft2
Hall
0 ft
9.4 R heaUcool
4.0 x 6.0 ft
24.0 ft2
Ty
Constmction
number
U-value
(Btuh/fP-°F
Or
HTM
I 2)
Area (ft2)
I or perimeter (ft)
Load
I Ohuh)
Area (ft2)
I or perimeter (ft)
Load
I (Btuh)
Heal(eluh/fl
Cool
Grass
I WP/S
Heal
Cool
Grass
I WP/S
Heal
Cool
I
I
I
1
I
I
e
1
13A-4ono
4A5-tom
,AS2om
13A4ocs
4AS20m
11D0
13A-40cs
4AS2om
13A-4ocs
tOD-f
11 DO
18XlMmd.
22Mtpl
0.
0.770 770
0,770
0.143
0.770
-0.390
0.143
-_0.7.70
0.143
0.420
n
n
-n_
a
a
_e_
s
,_s_
w
w
w
4D0
21.56
21.55
4.00
21.56
10.92
4.00
_21.56
4.00
11.76
10.92
=1.59.
27.69
2.
19.31 37
_79.3-1.
2.19
31.26
10.34
122
0
0
12
0 0
48
0 0
267
0
0
0
0
0
0
0
0
0
0
__ --
0
0
-0
122
15
0
-0-0
107
9
0
429
323
0
235
469
0
0
0
0
0
0
0
0
0
0
0
0
�D
_
2.19
-19.31
2.19
25.04
10.34
=1.37
0.00
0'
0
0-0
0-0-0--0
0--
0
0
0
0
-0-0-0
0
0
0
O
0
0
0
0
0
0
0
0
0
0
0
0
0
O
0
0
0
-0
0
0
0
-
F
_0.390
-0.408
0.989
�,
�169
169
� 16 9
26
266
720
231
0
,_„24
24
_24
�36
---33
0
0
0
61
c) AED excursion
_27
-7
Envelope loss/gain
2230
117
38
32
12
a) Infiltration
b) Rcamventilation
465
0
133
0
0
0
0
0
13
Internal gains: Occupants@ 230
Appliances/other
1
230
0
0
0
0
Subtotal (lines 6to 13)
2714
15371
1
1
38
32
14
15
Less external load
- Less transfer-
Redistribution
Subtotal
Duct loads
13%
10%
0
0
8
2722
359
0
0
6
1544
161
1
13%
1
10%
0
0
-38
0
0
0
0
-32
0
0
AiI
n)
I
I
1
312I
17o�( 80I
I
I
OI
Ita
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
F wn Right -Suite® Universal 201919.0.01 RSU08101 2019-Apr-181 Page6
...mentsXANghtsoft HVACIEvan Miller Residence.rup Calc=MJS Front Door faces: E
wrightscift Right-M Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St Lurie Lane. Fort Pierce. FL 34946 Phone: 77246"799 Email: quicAcalcs@aol.mm
1
2
3
4
5
Room name
Exposed wall
1 Room height
Room dimensions
Room area
Great Room
17.0 ft
9.4 it heat(cool
1.0 x 283.0 it
263.0 it
Ty
Construction
number
U-value
(Bluh/ft"F
Or
HIM
I (Btuh/ft0
Area ifP)
I or perimeter (it)
Load
I (Btuh)
Area
I or perimeter
Load
Heal
Cool
Gross
WP/S
Heat
Cool
Gross
I N/P/S
Heal
Cool
6
11
H—G
�G
13A-4ocs
4A5-2om
4A5-2om
13A4ocs
4A5-tom
11D0_
13AAocs
4A5-tom
13A-4ocs
10Pf
1100
-16X79-0md
0.143
0.770
0:770
0.143
0.770
_ 0390
0.143
—0.770
0.143
0.420
_,_0.390
_0.408
0.989
n
n
_n_
a
a
e_
s
_s_
w
w
w
4.00
21.56
_21,56
4.00
21.56
10.92
4.00
2.19
19.31
_19.31
2.19
31.26
10.34
2.19
0
0
0
0
0
0
0
0
0
0
1�
I--G
160
15
-0
124
9
__ 20
0
-0
498
323
223
0
272
469
_211
0
Yy��ll
_20
0
Vl/
LL_pG
_21,56.
4.00
11.76
10.92
__1.59_
_19.31
2.19
26.04
10.34
�1.37,
—0-0-0-0
0
0
_ 0
_283
0
0
_ _0
�283
0
0
0
449
471
0
0
0
—387
0
_
C_
F
_
22A-lpl _
27.69
0.00
_283
17
_
6
c) AED excursion
49
Envelope la5a/galn
1964
1290
12
a) Infiltration
b) Roam ventilation
317
0
87
0
13
Internal gains: Occupants® 230
Appliances/other
2
460
900
Subtotal (lines 6 to 13)
2281
2737
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
13%
10%
0
0
8
2288
302
0
0
6
2743
285
1
or Atae= a,1 1
1
1
2199001
3019
1
1
1
1
Calculations aooroved by ACCA to meet all reouirements of Manual J 8th Ed
*4- It. ofC 2019-Apr-1810:37:55
RlghtSuile® Universal 201919.0.01 RSU08101 page
...menls\Wrightsoft HVA(AEvan Miller Residence.mp Cale =MJ8 Front Door faces: E
Duct S stem Summa Job:
wrightsoft' Y � Date:
Entire House BY:
Quick Calcs, Inc.
317 St. Lucia Lane, Fort Pierce, FL 34W Phone: 772AG"799 Email: quickcelce@aol.com
Project• •
For: Evan Miller
5437 Ideal Holding Road, Fort Pierce, FL 34987
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest.friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.261
in/100ft
800
cfm
192 ft
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.261 in/100ft
800 cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mail
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bathroom
h 829
33
19
0.267
5.0
OxO
VIFx
32.5
155.0
st4
Bedroom 2
h 3081
121
80
0.266
7.0
Ox 0
VIFX
33.2
155.0
st4
Bedroom 3
h 3675
145
80
0.261
7.0
Ox 0
VIFx
36.9
155.0
st4
Closet
h 1144
45
18
0.387
5.0
Ox 0
VIFx
14.2
115.0
st2
Dining
c 1598
31
75
0.322
6.0
Ox 0
VIFx
20.4
135.0
st3
Great Room
c 3029
102
142
0.314
7.0
Ox0
VIFx
24.1
135.0
st3
Kitchen
c 2823
7
133
0.406
7.0
Ox0
VIFX
8.1
115.0
st1
Laundry
h 1779
70
59
0.398
6.0
Ox 0
VIFX
10.7
115.0
stl
Master Bath
h 2538
100
45
0.391
7.0
Ox0
VIFX
12.8
115.0
st2
Master Bedroom
o 3175
145
149
0.363
8.0
Ox0
VIFX
22.8
115.0
St2
Pantry
c 29
1
1
0.401
4.0
Ox 0
I VIFx
1 9.6
115.0
stl
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st4
Peak AVF
299
178
0.261
548
10.0
0 x 0
VinlFlx
st3
st3
Peak AVF
431
396
0.261
549
12.0
0 x 0
VinlFlx
sit
st1
Peak AVF
510
588
0.261
550
14.0
0 x 0
VinlFix
st2
Peak AVF
290
212
0.363
532
10.0
0 x 0
VinlFlx
C - wrtghtsofC 2019-Apr-1810:37:55
r-�..d... RlghtSuite® Universal 201919.0.01 RSU08101 Pagel
^��v...mentsXMghtsoft WACIEvan Miller Residence.rup Calc=MJB Fmnt Doorfaces:E