Loading...
HomeMy WebLinkAboutEVALUATION REPORTI 1, 1VALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION- • 126_GA. SV=CRIMP PANEL' , , SCANNED BY , St. Lucie County FLORIDA BUILDING CODE 6 TH EDITION (301[7) FLORIDA PRODUCT APPROVAL ,, f, ;Fi`L 14645.3-R3 ROOFING-. METALROOFING- Prepared For " Metal Sales Manufacturing Corporation 545 South 3rd 9treet,'Suite 200„ Lori Ville, KYV 40202, f 1' °sTelephone (502) 855=4300 ";:Fai: (502) 8554200 fig "I Xj t. ='Prepared•By .; , Bala Sockalingam,'PhD P.E Flot1da,Professional Engineer #62240 „ t 1216NSLansing- Ave, 'SuneC . Talsa,.OK 74106 Telephone: (918) 492-5992 ,- 6,36' 1543i=,', . , ThIs repOCt COn51St5 Of n r, , ,i' Evaluation Re ort 3 Pages including cover j n�nnu , �p g , g ) Ana uq� 411,,Jnstalla'tion Details (1 Page) ��` So0KAt4y pE NIf g:'Gq 62240 *: - - °• i ! ,v a :.ea , � "* ... s 4si 8:, Vi i-, ti atj I„ e STATE OF '�: Report No: C2182 3 • ,:'� Date:9.9.17 ;, •sir F < 0 R' o • Cs $ It a ii`SSrfl A����,� 0 FL 14645.3-R3 C2182-3 9.9.t7 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 3/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with TAS 125-03 'Standard Requirements for Metal Roofmg Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #I & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/1/09 I NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) DQSPNG SHINGLES (OPTIONAL) EXISTING UNDERIAYMENT (OPTIONAL) NEW UNDERLAYMENT - (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) E.c . AT ...n n eT TRUSS AT WAX 24` O.C. TYPICAL PANEL INSTALLATION X-SECTION #9-.I6 OR 110-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36' O.C. DETAIL 1 SV-CRIMP MIN 26 GA (MIN.) /9-15 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36' O.C. 5V-CRIMP MIN 26 GA EXISTING UNDERIAYMENTJ (OPTIONAL) PLYWOOD DETAIL 2 ' THICK (MIN.) SV-CRIMP ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PST) 35 41.6 16 74.0 B 196,75; GENEFLAL NOTES 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA (I = 0.01697. EFFECTIVE COVERING WIDTH OF PANEL = 24'. 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING @ STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM NAY NOT BE INSTALLED WHEN THE REWIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON TH6 DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING k THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. r. a w