.Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 915TM Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead applicallon along base of male. rib verkical Jf lge at E®acch panel
seam. CODE COMPLIANCE
FOR
Underlayment: To be compliant with FBC Sec 1507.1.1
ST. L.UCIE COUmTy
Slope: Shall be in compliance with FBC Sec.1507.
1 Install Details:- Table A Allowable, Loads
METHOD 1.
METHOD 2 ._ •_ ,- "
t DESIGN PRESSURE*
-96 PSF Main field
-97.25 PSF Perimeter
FASTENER SPACING
6" O.C.
6" O.C.
SEAM ADHESIVE i`
Not required
3/16" continuous bead
(see details)
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580,06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/1S Specimen #1 & #2
EQUIVALENCY: UL7897-04 is equivalent to Test Standard UL7897-12. *Desi n Pressure, mar in of safe --2:1. _
Certificate of Independence:
Locke Bowden, P.E: does not have, not will acquire a
underthisevaluation.
Locke Bowden, P.E. is not owned, operated, or contri
report;l'<
• c. � d �'� II
a
manufacturing or distributing products
or distributing products under this
'cam'`'" // -
• 'r • seal
•� STATE OF ; ( Q7
O f rv,:
% '("0 ZOR10%•�fi'.
P.oz63o
6�
Limitations:
1. Underiayment to be compliance with current Florida Building Code (FBC)2017 6"' ed..
2. Minimum slope to be compliant with Florida Building Code 2017 61� ed., and per with Manufacturers installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G203. Compliance Method:1-D
4. Engineering analysis for "project specific approval by local authorities wfjurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report
6. Support framing in compliance w/FBC 2017 61' ad., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report
FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
16"
—17—
3/4"
—_
Panel Profile
16" O.C.
FA
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3/16" Bead Bostik 915TA1 Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. per Table "A'
Pancake Head Mood Screw
(Typical Fastening Pattern Across Width)
Ili
FL 17022.5 1.0 Nail Strip (26GA Steel), W Wide Roof Panel -Details
15/k" or greater Plywood, or
- Wood plank
Pncf.ncr
Isometric View
1 4,
Apply 3MW' Bead Bostik 915" Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A)