HomeMy WebLinkAboutENCLOSURE PAPERWORK - POOLi General Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2"NO,MINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MN.) MEETING APPROPRIATE ACT AND ASTM REQUIREMENTS MAY BE USED N LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. S. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES -,46 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING 4A 1%- ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WPM HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: L CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE OF -TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4TROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-O" IN HEIGHT. C. ALUMINUM:; 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-TS FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO 'PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, NC. WASHINGTON D.C. THE FLORIDA BUILDING CODE 6th ED177ON ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH. DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7, 1"X2"XO.045"NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN N WOOD & #IOX 1/2" EMBEDMENT SMS OR TEK SCREWS N ALUMINUM MEMBERS TYPICAL. D. FASTENERS: 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS T(' ., ' SIM A 325, PLATED WITH STANDARD ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED - - FLAT WASHERS AND NUTS. HOME. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HETI, RAWL, 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING EQUAL. BARRIER REQUIREMENTS OF THEFBC 61h EDITION R 4501.17IN 4. ALL xIETAL TIES AND ASSOCIATED ACCESSORIES SHALL BE ITS ENTIRETY. HOT DIPPED GALVANIZED. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X CONTRACTOR. BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MN.). 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT ENSURE BONDING AGENT IS USED FIRST AND ADHERED WITH GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF MINIMUM 3000 PSI GROUT. THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE 5. SCREENING MATERIAL SHALL BE I SX14XO.013 OR INSERTED IN PILOT HOLES BY TURNING AND UNDER NO EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED CIRCUMSTANCES BY DRIVING WITH A HAMMER. ON DRAWING S•2. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE. LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR DESIGN DATA: OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS 1. ULTIMATE DESIGN WIND SPEED Vtd , (3 SECOND GUST): COMPLYWITH S SHALL WITH A. CONNECTORS ALL CONNECTORS SHALL COMPLY WITH ASTM A653 NOMINAL DESIGN WIND SPEED Vasd: CLASS G-185. C 2. RISK CATEGORY: 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING 3. WIND EXPOSURE: SHALE BE 3/4" AND MIINIMUM CZMFER-TO-EDGE SHALL BE 1/2" 4. WIND LOADS: UNLESS NOTED OTHER WISE. SCREENROOF: 12PSF E. REFERENCE STANDARDS:i ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAGAA. ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTNI C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 6th EDITION (CHAPTERS 16,20 & 23). F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP --TYPICAL 2. SIM -- SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4. CONT- CONTINUOUS 5. VIF - VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER 5. ANY DETAILS NOT SHOWN ARE TO'13E ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. A" MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO SCREEN WALLS: 43 PSF SOLID ROOF (MwFRS): N/A COMPONENTS AND CLADDING LOAD: NIA ISO MPH 116 n1PH I C S. FACTOR APPLIED TO SCREEN WIND LOADS FOR IEX14XO.013 SCREEN MESH: 0.89 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ONPRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLNS. 10 PSF VERTICAL DOWNLOAD ON SOLID ROOF. 8. PROPOSED 12"X 12" WI (1) # 5 OR (2) 04 REBAR W/ 25" OVERLAP ON 3" CHAIRS FILLED W/ 3000 PSI SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE 9. SCREENROOFTYPE: MANSARD 10. SOLID ROOF TYPE: N/A ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2----------------------------------------2„ x 2" x 0.044„ 2 x 3------------------- •-------------------- 2" x 3" x 0.050" 2 x 4----------------------------------------2" x 4" x 0.050„ 2 x 5:---------------------------------------2" x 5" x 0.050„ 3 x 3:---------------------------------------3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2----------------------------------------- 1"x 2" x 0.040" 1 x 3:----------------------------------------I" x 3"x 0.045" SNAP SECTIONS 2 x 2 SMS----------------------------------2" x 2" x 0.045" 2 x 3 SMS:---------------------------------2"x 3" x 0.072" 2 x 4 SMS:--------------------------------- 2" x 4" x 0.045" 3 x 3 SMS:-- ---- 3" x 3" x 0.090„ SELF MATING (SMB 2 x 4 SMB:----;---------•------ 2" x 4" x 0.044" x 0.100" 2 x 5 SMB----------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:--•---------•-------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMBr------=-------------- 2" x 7" x 0.057" x 0.120" Z x 8 SMB-------------•-------- 2" x 8" x 0.072"x 0.224" 2 x 9 SMB--------------•-------- 2" x 9" x 0.072" x 0.224" Z x 10 SMBr------------------ 2" x 10" x 0.092" x 0.374" TUBE`SECTIONS Z x 2--------------------------------------2" x 2" x 0.090?' i4jao'Gt:p3a) REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 0i�i�v F AL, ®®� C�°� °OCEN, _® No- 70C m�a � <o STATE S °NA L' CI NIA �IJr�F GGn� 11 ENGINEER OF RECORD: David W' . Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson RE FLORIDA LICENSE: 38654 Mark R: Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services; Inc. 6272 Abbott Station Dr. Unit.101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824.7894 E-mail-erb@fbcplans.com W ebsite-Www.fbcplans,com C.O.A. #29054 DATE: 4/24/2019 DRAWN BY: TLX REVISION: DATE: RO 1 RO 2 RO 3 RO 4 job# 19-0417 109 PROJECT ADDRESS: SASSEBILLE 25 MAJESTIC WAY FT. PIERCE, FL 34949 POD ALUMINUM INC. 5 VICKIE CIR .BOURNE. FL 32904�, NOTES St" S-1 Agd` 7 e jGN l SHALL NOT BE REPRODUCED LX2 2X2 1X2 13'-814 IN -FILLS INCLUDED 36' Mansard Rise PROPOSE 8"X 8" W/ (1) #5 OR (2) #4 REBAR LINEAL FOOTING _ O 00 I I I -101 ' -loll REVIEWED FOR CODE_ COMPLIANCE ST_ LUCIE COUNTY ,�.MPIx nE -I/ .......... , a66 e o uI Ce W W 2 i iE AP.• �9� c9 r_.111111110 ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE:38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans& Engineerir Services, Inc. 6272 Abbott Station Dr. Unit 101 ZephyrhiOs,FL33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.tb cplans.com C.OA-#29054 DATE: 4/24/2019 DRAWN BY: TLK REVISION: DATE: RO 1 7/17/2019 RO 2 IR03 I @R04 I I ;OJECT ADDRESS: iSEBILLE MAJESTIC WAY PIERCE, FL 34949 )D ALUMINUM INC. VICKIE CIR ;OURNE, FL 32904 FLOOR PLAN S-2 comw THIS PA T WTTNODT EXPRESSED WRITTEN PERMISSION OF T C DESIGN, UC 2" x _PURLINS (SEE S-2 FOR SIZE)ATTACHED TO BEAM — @/MIN (4) #10 x I X" SMS "B" NUMBER OF #12 x 3/4" SMS PER SECTION (2 PER—� SIDE 4 SECTIONS TOTAL) 9 w o� 1/8" (11 GA.) ALUMINUM GUSSET PLATE • QN Q(A BEAM "B" J BM TOTAL 2x4 14 28 56 2x5 14 28 56 2x6 14 28 56 2x7 16 32 64 2x8 16 32 64 2x9 18 36 72 2x10 18 36 72 G: 2" x 2"x2" ANGLE EA SIDE W/ (4) #12 X 3/3" SMS EA LEG- 2" x 2"EAVE RAIL SNAP SECTION (UNLESS OTHERWISE SHOWN ON S-2) -ATTACHED TO BEAM W/- (3) LOX 2" SMS INTO SCREW BOSS 1"X2"OPEN BACK SNAP ATTACHED TO EAVE RAIL w/(1)_ (3)LOX 2" SMS INTO SCREW BOSS (1) 1/2" 0 x 21/2" THRU BOLT W/NYLON LOCK NUT, JAM NUT W/_ THREAD LOCKER MAY BE USED AS ALTERNITIVE (1) #12X 3/4" SCREW (ONE ABOVE, CENTERED & ONE BELOW CENTERED) OPTIONAL: 1"X2"OPEN BACK ATTACHED TO HOST W/ (1) 1/4"0 CONCRETE SCREW OR LAG WITHIN 6" OF BEAM & @ 24" O.C. MAX D, BETWEEN BEAMS 0 E E G. 0 t O N D] #120X 3/4"SMS SHALL ? O MAINTAIN 1-1/4 D.C. H O SPACING AROUND SECTION (B) -1/4" 0 CONCRETE SCREW O W/ e" GUSSET PLATE PER c W/ 1-1/2" EMBEDMENT INTO O SECTION MASONRY (1-1/2" MIN. SPACING OR �i NOTES: 1. GUSSET DIMENSIONS AREA MINIMUM OF 8" PER SECTION PER SIDE OR 16". 2. TOTAL NUMBER OF SCREWS PER JOINT EQUALS 4 TIMES SECTION. 3. PLATE WIDTH SHALL BE DETERMINED ON DEPTH OF BEAM, LENGTH SHALL STAY CONSISTENT. 4. GUSSET PLATES EXTERNAL OR INTERNAL. 5. INTERNAL SCREWS FOR PURLIN CONNECTION MAY NOT BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPLICE WILL HAVE THE SAME PATTERN. SELF -MATING BEAM SHALLBE NOTCHED FOR UPRIGHT (MIN) UPRIGHT NOTE: INSTALLATION OFTHRU BOLT: BOLT IS NOT BE TIGHTENED AS TO DISTORT ALUMINUM MEMBER. / L \ UPRIGHT TO BEAM CONNECTION -THRU BOLT \ S_'; / SCALE: NTS (B)- 1/4" 0 X 2" LAG SCREWS INTO WOOD (1" MIN SPACING) (TYP 2 LOCATIONS) BEAM 2x4 2X5 2x6 2x7 2X8 2x9 2x10 EAVE (5)- #14 X ATTACHING ANGLE TO BEAM EACH SIDE (1" MIN. SPACING) / / LSLOPED OR FLAT ROOF BEAM (SEE SHEET S-2 FOR SIZE) _2"X2"X 0.125" ANGLE EA. SIDE OF BEAM 1. THE MINIMUM EDGE DISTANCE EXISTING HOST STRUCTURE IS 3" FOR MASONRY STRUCTURES. (CONCRETE, GROUT FILLED 2. IF A RECEIVING CHANNEL IS CMU OR WOOD) USED, USE TWICE THE NUMBER "B" ANCHORS INTO THE HOST STRUCTURE. ALL MINIMUM SPACING SHALL BE APPLICABLE. �\ OPTION #3 ( ti \ BEAM TO HOST TO CONNECTION DETAIL S-3 SCALE: NTS (2) 414X 2" SMS SCREWING BRACE TO (1) 1/4"0 THRU BOLT W/ NYLON LOCKING NUT OR THREAD LOCKING MATERIAL APPLIED W/ WASHER 1-1/2"X5".125"PLATE #14 X3/4" EACH MI ROOF "FENDER WASHER ,yp) EA END ( E \ ROOF BRACING CONNECTION DETAIL S`_'3 SCALE: N.TS 2" X6" X.0625" PLATE EA 2"x2"SNAP EXTRUSION (2)#10x 3" SMS x 2" OPEN NOTCH POST AS N • 0- 01p i�0 •• •• FLOta�pP��G 3lOR1PV\\�\ ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 OPTIONAL:2"X 7 X062"ANGLE Thomas L. Hanson P W/ (4) #12 EA LEG FLORIDA LICENSE: 38654 #12 x 31V TEKS Mark R. Dunn P.E. CHMEMBER FLORIDA LICENSE: 73968 Joel Falardeau P.E. ;HT FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineerh C Services, Inc. SLOPED OR FLAT PURLIN CONNECTION DETAIL 6272 Abbott Station Dr. Unit 101 S-3 SCALE: NTS Zephyrhills, FL 33542 Ph#(813)788-S314 Fax# 1-(866)824-7894 E-mail-erb@tbcplans.com W ebsite-www.fbcplans.com C.OA. #29054 NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (4) #10 x 5/8" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. 3. HINGESSHALLBE ATTACHED TO DOOR WITH (4)910 x 5/B" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. REVIEWED FOR TYPICAL SCREENrTYPICALSCREEND kWOMA IANCE s-3 5Y• LUCIE COUNTY DATE: 4/24/2019 DRAWN BY: TLK REVISION: DATE: RO1 7/17/2019 RO 2 RO 3 RO 4 PROJECT ADDRESS: MAJESTIC WAY . PIERCE, FL 34949 )D ALUMINUM INC. VICKIE CIR ;OURNE, FL 32904 DETAILS S-3 IK 1' "" ]'� IN WHOLE OR IN PART WNHOOT EXPRESSED WRNTEN PERMISSION OF TRAC DESIGN, LLD 2° x 2 x.125° ANGLE UPRIGHT - TYP 2'X2'X325' ANGLE W(I)1/2' CAP SCREW w/ NYLOCK JAM NUT - IN LIEU SECONDARY I OF NYLOCK ]AM NUT, JAM NUT w/ 2-X2'X325'ANGLEW/ r�00 T HREAD LOCKER MAYBE USED (3) #12 X3/4' SMS EA, TIGHTEN TO CONTACT. DO NOT SIDE ADD (1) H12 FOR OVER TIGHTEN. EVERT INCREASE IN UPRIGHT SIZE &ANGLE O �1'x 2'O.B. OPTION #1 fA)#10 x I%"SMS INTOSCREW BOSSES�W/.062 BACKER PLATE OPTION #2 RECEIVING CHANNEL EA. SIDE ORANGLEICKNESS (typJ (•0625"THICKNESS) . j 2"x6" SMS EXAMPLE J 1 ^n 3n / ° 325'ANGLE JAM NU -CAP SIDE VIEW'_ OFNYLO KJAMNK)AMNUUT W/ LIEU SCREW IpE USE w/ OFREAD LOCKER MAYBE THREAD LOCKER MAY BH USED TIGHTEN TO CONTACT • DD NOT O — — — — (3)1/4" ox'-3/4° OVER TIGHTEN. — — — — EMBEDMENT MIN. 1' x 2' BASE PLATE ANCHORED TO 2"X2"OR2"X3" #10X3 4"SMS (2) / SECONDARYANGLE CONCRETE W/1/4'0X 3' MASONRY PURLIN OR GIRT (typ)EA. LEG) TYPE SCREW EACH SIDE OF UPRIGHT (TOTAL 6 SCREWS P C. (8) IN ANGLE AND 2M1°O.G. MAX-1 -3/4" SCREWS ANGLE EA. — — — EMBEDMENT CONNECTION) A H n PURLIN OR GIRTTO BEAM OR POST DETAIL S 4 SCALE:NTS NOTES: FRONTVIEW' 1. ALL ANGLES SECURING UPRIGHT TO CONCRETE SHALL BE 2'X3"XZ"X12S"OR 2"X2"X2"X325" W/ (1) TAPCON PER- ANGLE. MINIMUM (2) ANCHORS PER UPRIGHT (typ). 2. OTHER CONCRETE ANCHORS OF EQUIVALENT SPECIFICATIONS MAYBE USED. 3.2"XZ" THIRD 2"x5" SMB SHALL HAVE PRIMARY ANGLE ONLY-2"X6" SMB &ABOVE SHALL USE SECONDARY 2"X3"X2"X325" ANGLE W/ (3) #12 x 3/4" SMS & (1) 1/4" 0X2" TAPCON CONCRETE ANCHOR PER SIDE. / G \ 2" v 2" HnT.I.nW f1R LARGF.RIIPRIGHTTO CONCRETE IIRTAIIS (1) #5 CONTINUOUS (OR (2) #4 25" OVERLAP ON 3" 12"x 12" LINEALFOOTING NOTES FOR ALL FOUNDATION TYPES: 1. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF LSOO PSF. THE BEARING CAPACITY OF THE SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO ANY POURING Op CONCRETE. 2. THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND COMPACTED PRIOR TO POURING OF ANY CONCRETE. 3. CONCRETE MEET THE SPECIFICATIONS 1NA, S-1 NOTES PAGE. K CONTINUOUS FOOTING S4 NUi lUbLALb REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY It101it A'R D eee®`P� i�NSE 4U ; 66Z o tX ®0 �� °ate N°- 4 su,® ' �FFSSIONP� \ee® ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE:70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824.7894 E-mail-erb@ fb cplans.conR W ebsite-www.fbeplans.com C.O.A. #29054 DATE: 4/24/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 Job# 19 0417_109 PROJECT ADDRESS: 3ASSEBILLE 75 MAJESTIC WAY FT. PIERCE, FL 34949 CONTRACTOR: TRIPOD ALUMINUM INC. 6915 VICKIE CIR MELBOURNE,FL32904( DETAILS S-4 OR IN PART WITHOUT