Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL.. ED AIL s _ COPY ®Y"'Zra.n St. Lucie County pas H me : Log In u rRegbtraren I Hut Topim 5-b-1 Sru n nle Sore, SFa[6 i PotA.Hlm E SSd Nav links 5^zrt�. 0� Product Approval ^, 11uspR: wino user a-...>vt Ctir'.ttM, enlni 25—rd>4ncEc t lsl>APP1kxti0n Detail FL C Application Type Code Version Application Status Comments Archlved Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance. Method FL17022-R7 Revision 2017 Approved REVIEWED FOR CODE COMPLIANCE IBOCC O811812017u. date reapply 06/21/17 Extreme Metal Fabricators, LLC 2160 SW Portia Drive Palm City, FL 34990 (772)872-8034 nvalidation@Yahoo.com Richard MCKuhen fivalidation@yahoo.com Richard MCKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Fonda Professional Engineer CJ Evaluation Report - Hardwpy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 validated By zactury R. Priest, P.E. Z Validation Checklist - Hardcopy Received Certificate of Independence FLi 7022 RJ C_Oi eL 17022.1 5 V CRIMP <5-odf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code year 2003 2012 2006 Palm City, FL 34990 Compliant with Florida Building Code 2017 (6t1i ad.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength. 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/81' Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/1V min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" O.C. 8" o.c. 6" O.C. FASTENER SPACING (ALONG Panel width 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENERSIZE #9 #10 #10 #10 d Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report EMS93.01-450-18 05/02/14 Test Report F3366.01-450-18 12/19/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent M test standard UL 1897-1i7i*Design pressure margin of safety 2.1 •tnik Locke Bowden, P.E. does not have, not will acquire a financial under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by i report. cgj4prdy4Niacturingor distributing products compartiomltitilf9tureo, or distributing products under this E a / 1� 1 .f�Y _• x.J j+� _ ' ST:11 ;•.Fteralo. .O. IAL FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ad. 2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wfjurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6� ad., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 49. 1-11, MI. or at0.1-12'Rlin. per ay¢A'br Roux �6V Crimp Root Panel Spar and ASm ms Hex Washer HeaC dWw Woad Spews Cedc Wmd -arBreda P.'ywaf,a -Vdgodplank 24' 1r� L Panel Profile 12" \ ' f Fasten x 1-1/2" Min. or 910 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Panel Spaced 12" o.c. across the Panel Width Refer to Table "A" far Spacing Along Panel Overlap Length Deck-15132" or greater Plywood, or -Wood plank F7Orida Building Code Online Page 1 of 2 SCANNED m ll g • r4 t, BY� St. Lucie Countv i BOS Home I Log In i User Registration •I Hot Topic I Submit Surcharge I stabs 6 Facts I Publications ( contact us I SCIS site Map i Unks i Search ( d[lod da�� FILE P Product Approval 9 USER: Public User e '' , ,. + product Approval Menu > Product or Aoolication Search > poollcaUY on Lis Application Detail � �� b ' • FL # FL5259-1128 FI L Application Type Revision Code Version 2017 fi'9EVIE ED [� •�a'� Application Status Approved CODE COMPLIANCE ®fa P 16ANCE Comments ST. LUCIE C®U�Ty ❑ Archived B®CC (�, Product Manufacturer POLYGLASS USA J Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912)429-8610 MAlpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W. Knezevich, PE 9 Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R28 COI 2018 01 COI NIEMINEN.odf Referenced Standard and Year (of Standard) Standard Vear ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2vSd/o2... 6/5/2019 , Florida Building Code Online UL 1897 Page 2 of 2 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 Summary of Products r FL # Model, Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R28 II 2018 OS FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R28.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular FL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R28.odf underlayment system (over concrete deck) for use under foam -on the systems (where Created by Independent Third Party: Yes the underlayment forms part of the load - path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us :: 2601 Blair SWe Road. Tallahassee FL 32399 Phone, 850-487-1824 The State of Honda Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by trad clonal mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4ss, F.S. must provide the Department with an email address if they have one. The emals provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please crick bey. Product, Approval Accepts: ® R�57 -°E Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2vS%2... 6/5/2019