Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutENERGY EFFICIENCY CODE'FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODM ILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ADAMS HOMES- 1820 B MODEL
Builder Name: ADAMS HOMES
SCANNED
Street: 5313 SAN BENDETTO PLACE
Permit Office: ST LUCIE COUNTY
BY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
St-. Lucia onlingy
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1890.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- EM Insul, Exterior
R=4.1 1656.00 ft2
b. Frame- Wood, Adjacent
R=11.0 234.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= 112
5. Is this a worst case? No
10. Ceiling Types (1820.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(199.3 sgft.) Description Area
a. Sup: Attic, Ret Attic, AH: AHU CLST
6 150
a. U-Factor: Sgl, U=0.65 186.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.70 13.33 fN
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
35.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
27.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.253
14. Hot water systems
8. Floor Types (1820.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
EF: 0.900
b. N/A R= ft2
None
c. N/A R= W
15. Credits
None
Glass/Floor Area: 0.110 Total Proposed Modified Loads: 61.75
PASS
Total Baseline Loads: 63.87
1 hereby certify that the plans and specifications covered by
Review of the plans and
Srq?�
this calculation are in compliance with the Florida Energy
specifications covered by this
QFTNg
Code.
calculation indicates compliance
yk3 ,, '.
°„
with the Florida Energy Code.
nw2•; ;'::ice;>. O
PREPARED BY:
Y:
Before construction is completed
DATE: 4-2
this building will be inspected for
compliance with Section 553.908
1:4 a
r e
I�iereby certify that this building, as designed, is in
Florida Statutes.
9�
with the Florida Energy Code.
COp WE
OWNER/Ar-' , �Yi
" `
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/29/2019 1:32 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
ADAMS HOMES- 1820 B MO
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
1820
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle:
0
Street:
5313 SAN BENDETTO
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
LOW
BLOCKS
Number
Name
Area
Volume
1
Entire House
1820
16380
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
BEDROOM2
130
1170
No
0
1
1
Yes
Yes
Yes
2
CLST 2
17
153
No
0
1
Yes
Yes
Yes
3
BATH 2
54
486
No
0
1
Yes
Yes
Yes
4
BEDROOM 3
130
1170
No
0
1
1
Yes
Yes
Yes
5
CLST 3
27
243
No
0
1
Yes
Yes
Yes
6
AHU CLST
12
108
No
0
1
No
Yes
Yes
7
DINING ROOM
220
1980
No
0
1
Yes
Yes
Yes
8
BEDROOM 4
161
1449
No
0
1
1
Yes
Yes
Yes
9
CLST 4
21
189
No
0
1
Yes
Yes
Yes
10
FOYER
48
432
No
0
1
Yes
Yes
Yes
11
LAUNDRY
49
441
No
0
1
No
Yes
Yes
12
KITCHEN
262
2358
Yes
0
1
Yes
Yes
Yes
13
FAMILY ROOM
264
2376
No
0
1
Yes
Yes
Yes
14
HALL
32
288
No
0
1
No
Yes
Yes
15
0 BATH
131
1179
No
0
1
Yes
Yes
Yes
16
0 WIC
38
342
No
0
1
No
Yes
Yes
17
OWNERS BEDRO
224
2016
No
0
1
1
Yes
Yes
Yes
4129120191:32 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 2
33 ft
0
130 ft2
-___
1
0
0
2 Slab -On -Grade Edge Insulation
CLST 2
2 ft
0
17 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulation
BATH 2
6 ft
0
54 W
____
1
0
0
4SIab-On-Grade Edge Insulation
BEDROOM
10ft
0
130W
----
1
0
0
5SIab-On-Grade Edge Insulation
CLST 3
3 ft
0
27 W
--
1
0
0
6SIab-On-Grade Edge Insulation
AHU CLST
1 ft
0
12 ft2
___
1
0
0
7SIab-On-Grade Edge Insulation
DINING ROOM
11 ft
0
220 ft2
____
1
0
0
8SIab-On-Grade Edge Insulation
BEDROOM 4
24 ft
0
161 ft.
--
1
0
0
9SIab-On-Grade Edge Insulation
CLST 4
8 ft
0
21 ft2
_-__
1
0
0
10SIab-On-Grade Edge Insulation
FOYER
E ft
0
48 ft'
____
1
0
0
11SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
49 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
KITCHEN
16 ft
0
262 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
FAMILY ROOM
13 ft
0
264 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
HALL
1 ft
0
32 ft2
____
1
0
0
1551ab-On-Grade Edge Insulation
O BATH
11.9 it
0
131 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
OWIC
1ft
0
38 ft2
1
0
0
17SIab-On-Grade Edge Insulation
OWNERS BEDR
40 It
0
224 ft2
--
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emilt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2035 ft2
0 ft2
Medium
0.6
No 0.9
No
0
26.6
ATTIC
/
`�
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
300
1820 fl2
N N
4/29/20191:32 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
130 ft2
0.1
Wood
2
Under Attic (Vented) CLST 2
30
Blown
17 ft2
0.1
Wood
3
Under Attic (Vented) BATH
30
Blown
54 ft2
0.1
Wood
4
Under Attic (Vented) BEDROOM
30
Blown
130 ft2
0.1
Wood
5
Under Attic (Vented) CLST3
30
Blown
27 ft2
0.1
Wood
6
Under Attic (Vented) AHU CLST
30
Blown
12 fP
0.1
Wood
7
Under Attic (Vented) DINING ROOM
30
Blown
220 ft2
0.1
Wood
8
Under Attic (Vented) BEDROOM 4
30
Blown
161 W
0.1
Wood
9
Under Attic (Vented) CLST4
30
Blown
21W
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
48 ft2
0.1
Wood
it
Under Attic (Vented) LAUNDRY
30
Blown
49 ft2
0.1
Wood
12
Under Attic (Vented) KITCHEN
30
Blown
262 ft2
0.1
Wood
13
Under Attic (Vented) FAMILYROOM
30
Blown
264 ft2
0.1
Wood
14
Under Attic (Vented) HALL
30
Blown
32 ft2
0.1
Wood
15
Under Attic (Vented) 0 BATH
30
Blown
131 ft2
0.1
Wood
16
Under Attic (Vented) OWIC
30
Blown
38 ft2
0.1
Wood
17
Under Attic (Vented) OWNERS BEDR
30
Blown
224 fN
0.1
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing
Solar
Below
0
1
NE
Exterior Concrete Block - Ext InsiBEDROOM 2
4.1
10
0 9
0
90.0 ft2
0
0
0.6
0
2
SW
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
10
0 9
0
90.0 ft2
0
0
0.6
0
_ 3
NW
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
13
0 9
0
117.0 ft2
0
0
0.6
0
4
SW
Exterior Concrete Block- Ext Insul CLST 2
4.1
2
0 9
0
18.0 ft2
0
0
0.6
0
5
SW
Exterior Concrete Block - Ext Insul BATH 2
4.1
6
0 9
0
54.0 fl2
0
0
0.6
0
6
SW
Exterior Concrete Block - Ext InstBEDROOM 3
4.1
10
0 9
0
90.0 ft.
0
0
0.6
0
7
SW
Exterior Concrete Block - Ext Insul CLST 3
4.1
3
0 9
0
27.0 W
0
0
0.6
0
8
SW
Exterior Concrete Block - Et InsOINING ROO
4.1
11
0 9
0
99.0 ft.
0
0
0.6
0
9
BE
Exterior Concrete Block- Ext Ins51EDROOM 4
4.1
11
0 9
0
99.0 ft2
0
0
0.6
0
10
SW
Exterior Concrete Block -Ext lnstSEDROOM4
4.1
13
0 9
0
117.0ft2
0
0
0.6
0
11
NE
Exterior Concrete Block- Ext Insul CLST 4
4.1
5
0 9
0
45.0 fl2
0
0
0.6
0
12
BE
Exterior Concrete Block - Ext Insul CLST 4
4.1
3
0 9
0
27.0 ft2
0
0
0.6
0
13
SE
Exterior Concrete Block - Ext Insul FOYER
4.1
6
0 9
0
54.0 ft2
0
0
0.6
0
_14
NE
Garage Frame - Wood FOYER
11
6
0 9
0
54.0 ft2
0
0.25
0.6
0
Ilk 15
SE
Garage Frame -Wood LAUNDRY
11
7
0 9
0
63.0 f12
0
0.25
0.6
0
16
NE
Exterior Concrete Block- Ext Insul KITCHEN
4.1
16
0 9
0
144.0 f12
0
0
0.6
0
17
SE
Garage Frame -Wood KITCHEN
11
13
0 9
0
117.0W
0
0.25
0.6
0
18
NW
Exterior Concrete Block- Ext lnsOAMILY ROO
4.1
13
0 9
0
117.0 f12
0
0
0.6
0
19
NE
Exterior Concrete Block- Ext Insul 0 BATH
4.1
12
0 9
0
108.0 ft2
0
0
0.6
0
_20
NE
Exterior Concrete Block -Ext lnsOWNERS BE
4.1
16
0 9
0
144.0 ft2
0
0
0.6
0
21
SW
Exterior Concrete Block -Ext InsOWNERS BE
4.1
10
0 9
0
90.0 ft2
0
0
0.6
0
22
NW
Exterior Concrete Block -Ext InsOWNERS BE
4.1
14
0 9
0
126.0 ft2
0
0
0.6
0
4/29/2019 1:32 PM EnergyGaug& USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPf)RT
DOORS
#
Omt
Door Type
Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
2
SE
NW
Insulated
Insulated
FOYER None
FAMILY ROO None
.39 3
.39 2 8
6 8
6 8
20 ft2
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
_ 1
2
3
4
5
6
_ 7
8
9
10
NW 3 Metal
SW 6 Metal
SW 8 Metal
SE 9 Metal
SE 13 Metal
NE 16 Metal
NW 18 Metal
NE 19 Metal
NE 20 Metal
NW 22 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.7 0.3 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
0.65 0.25 N
15.0 ft- 2 ft 0 in 1 ft 4 in
15.0 ft2 2 ft 0 in 1 ft 4 in
30.0 ft2 2 ft 0 in 1 ft 4 in
30.0 ft2 2 ft 0 in 1 fl4 in
13.3 ft2 2 ft 0 in 1 ft 4 in
30.0 ft2 2 ft 0 in 1 ft 4 in
30.0 ft2 2 ft 0 in 1 fl4 in
6.0 ft2 2 ft 0 in 1 fl4 in
15.0 ft2 2 ft 0 in 1 ft 4 m
15.0 ft2 2 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
400 ft2
400 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.0004
1911 104.91 197.3 .3005
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit'
Split
SEER: 15
35 kBtu/hr 1050 cfm
0.8 1
sys#1
`
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
None
Garage
0.9 50 gal 60.9 gal 120 deg
None
4/29/2019 1:32 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Carl # Company Name
System Model #
Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
-- Supply—
•-- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6
150 W Attic
15 ft2
Default Leakage
AHU CLST (Default) c(Default) c
1 1
TEMPERATURES
Programable[[T��hermostat::[
Ceiling Fans:
]]N
Venting [X) Jan [X] Feb
f[X],]
[ ]
Mar [ ] Apr
[XJ
[ ] Jun
[X�
[ ] Jul
D0
[ ] Aug
[X]
[ ] Sep
[[X�]
Nov
Nov
Dec
Decec
Venting [[ 11 Jan II 11 Feb
IXl
lxl
Mar [XI
May
I 1 Jun
[ 1 Jul
I 1 Aug
[) Sep
Oct [X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (W D) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Cooling (W EH) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating (WO) AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
HeaBng(WEH) AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(81bs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 lbs/sq.ft.
ft,
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 lbs/sq.ft.
ft,
ft
0.3
CLST 3
Default(8 lbs/sgJt.
ft2
ft
0.3
AHU CLST
Default(8 lbs/sq.ft.
ft2
ft
0.3
DINING ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 lbs/sq.ft.
ft2
ft
0.3
CLST4
Default(81bs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
FAMILYROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
• Default(8 lbs/sq.ft.
ft2
ft
0.3
O BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
O W IC
Default(8 lbs/s.ft.
ft2
ft
0.3
OWNERS BEDRO
'
Name:
Rating Compant:
Date: 4-29-19
4/29/2019 1:32 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
35.0
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6. 1820
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.653
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.253
14. Heating system: Capacity
27.0
c) Area
7c. 199.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heal Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signa � e
� -
t1 Date: 1 I25 I ( c1
Address of New Home: 5313 SAN BENDETTO PLACE City/FL Zip: FORT PIERCE, FL
4/29/2019 1:32:51 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: ST LUCIE COUNTY
Permit #:
Job Information
Builder: ADAMS HOMES Community: Lot: NA
Address: 5313 SAN BENDETTO PLACE
City: FORT PIERCE State: FL Zip:
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
O PRESCRIPTIVE METHOD -The building or dwelling, unit shallbe tested and verified as having an air leakage rateof not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g.(50 Pascals) in Climate Zones 1 and 2.
Q PERFORMANCE or ERI METHOD-Thebuilding or dwelling unit shall betested and verified as,having an air leakage rate of not exceeding -
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACH50.
ACH(50) specified on Form R405-2017-Energy Calc.(Performance) or R406-2017 (ERQ; Z000 ;
x 60 = 16380 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
❑ PASS Code
0 software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode of bial. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the lest, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
4/29/2019 1:33:20 PM EnergyGauga USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Project SummaryJob: 1820MODELB
wrightsoft' Entire House DDate: Apr29,2019
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fm 772466,6796 EnraiC OUICKCALCS@AOL.COM
Project Information
For. ADAMS HOMES
5313 SAN BENDETTO PLACE, FORT PIERCE, FL
Notes:
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/Ib
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 21540
Btuh
Structure
18080
Btuh
Ducts 5652
Btuh
Ducts
8096
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 27192
Btuh
Use manufacturers data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
24867
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
4281
Btuh
Ducts
2194
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Area
Cool'
(none)
(ft�) 1820
1820
Equipment latent load
6475
Btuh
Volume (ft3) 16380
16380
Air changes/hour 0.38
0.20
Equipment Total Load (Sen+Lat)
31342
Btuh
Equiv. AVF (cfm) 104
55
Req, total capacity at 0.70 SHR
3.0
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIER
Trade CARRIER
Model CH14NBO3600GOBO
Cond CH14NBO3600GOBO
AHRI ref 9162518
Coil FX4DNF049L
AHRI ref 9162518
Efficiency 8.5 HSPF
Efficiency 12.5 EER, 15
SEER
Heating input
Sensible cooling
24500
Btuh
Heating output 34000
Btuh @ 477
Latent cooling
10500
Btuh
Temperature rise 27
OF
Total cooling
35000
Btuh
Actual airflow 1167
cfm
Actual airflow
1167
cfm
Air flow factor 0.043
cfm/Btuh
Air
flow factor
0.045
cfm/Btuh
Static pressure 1.00
in H2O
Static
pressure
1.00
in H2O
Space thermostat
Load sensible heat ratio
0.80
Capacity balance point = 36 OF
Backup:
Input = 7 kW, Output = 24822 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
-rk- =rights ft- 2019-Apr-29 13:17:40
RlghtSuite® Universal 2018 18.0.31 RSU08101
-� ...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.nip Calc = MJ8 Front Door faces: SE Page 1
wrightsoft' Right-M Worksheet Job: 1820 MODEL B
Entire House Date: Apr29,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: OUICKCALCS@AOL.COM
1VRm
me
Entire House
BEDROOM 2
2
3ight
wall
183.9 It
9.0 ft
33.0 It
9.0 ft heat/cool
4mensions
5rea
1820.0 ft'
13.0 K 10.0 If
130.0 fl'
Ty
Construction
number
U-value
(Btuh/WF)
Or
HTM
(Btuh/ftj
Area (w)
or perimeter (ft)
Load
(Btuh)
Area (ft')
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
I-G
13A4oc9
2 glazin cir lowe
2 glazrtg, clr lave
13A-0acs
2 glazing, cir low-e
2 glazing, cir lowe
___._
13A flocs
- _0:143
0.650
_ _ 0.650
0.143
0.650
0.650
_ _ 0.390
0.143
-rle-
ne
_ ire_
se
se
se
_se_
sw
..- 4.00
18.20
1820
406
18.20
1820
10.92
- -4.00
2.19
26.88
26.88
2.19
21.07
22.59
_,_10.34
2.19
.".-331
6
_ _ _ 45
180
30
13
20
585
..-.__480
0
_.._ __ 0
117
15
5
_20
540
_.__..1922..
109
819
-4-66
546
244
_ _ _ 219
2162
_.._.ice
161
1209
---255-
632
303
208
- 1181
_.._._ 90
0
0
0
0
0
_ _ 0
�90
_- _..90
0
0
-- -- p
0
0
0
_ _90
_... __.360
0
0
--- 0
0
0
0
_ .. _ _3w
197
0
0
- �--0
0
0
0
- -197
V)J
F�-ffD'
V+/ -
G
2 glazing. cir lowe
13A-4ocs
,__. 0.650
0.143
.sw
rw
__18.20
4.00
.21.07
2.19
_._..__45
360
____22
282
____819
1130
_. __948
617
_.
_ __ -.0
117
_ - _.0
102
. _-_-0._----
408
_.0
223
__ _
C_ .. _
2 glazing, clr lowe
11DO _ . . ._
16B30ad. _ _
0.650
_ _0.390
..0.032
mw
rw
_ -
18.20
10.92
_..0.90
26.88
_10.34
1.60
60
_ 18
.v_ 1820
0
_ __ 18
_ _. 4820
1092
__ 195
. _. 7631
1613
185
�- .2912
15
0
- 130
0
_ .. 0
. _ .130
273
_ . 0
403
_ _ _ 0
.. 208
22Q_toh _ _ _ _ _ _
_ 1.358
- .
38.02
_ U0
_ 1820
. __ 184
_ _ _ 6993
_ _ 0
._ _
130
33
_ _116
1255
_
0
6
c) AFJD excursion
456
79
Emelope loss/gain
18348
11730
2773
1307
12
a) Infiltration
3192
900
573
161
b) Room ventilation
0
0
0
0
13
Internal gans: Occupants @ 230
0
0
0
0
Appliances/other
5450
0
Subtotal Qines 6to 13)
21540
18080
3346
1469
Less e#emal load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
0
21540
0
0
18080
0
105
3451
0
46
1515
15
Duct loads
26%
45%
5652
8096
26%
45%
905
678
r187
Total mom load
27192
26176
4356
2193
PJr required (cfm)
1167
1167
98
Calculations aooroved bvACCA to meet all reauirements of Manual J 8th Ed
-+}r- wr19�+�so4ft- 2019-Apr-2913:17:40
A RlghtSuite® Universal 2018 18.0.31 RSU08101 - Page 1
...S HOMES. 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: SE
wrightsoft, Right-J@ Worksheet Job: 1820 MODEL B
Entire House Date: Apr29,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
CLST 2
BATH 2
2
E)posed wall
2.0 It
6.0 ft
3
Room height
9.0 ft heat/cool
9.0 0 heat/cool
4
Room dmensions
9.0 x 20 it
9.0 x 6.0 ft
5
Room area
18.0 ft'
54.0 W
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area (ft-)
Load
number
(Btuh/ftMF)
(Btuh/ft�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Coot
Gross
N/P/S
Heat
Cool
6
13A-00c§ _ .. .__
_. 0.143
, ne-
_ . _4.00
"219
_0
. .0
.. _....0
_ _ . _ _.0
_ _ __0
0
._. _ 0
0
t�-GG
2 glazing, co- lowe
0.650
m
1820
26.88
0
-0
0
0
0
0
0
0
2 glazing, clr low-
_-
.__ 0.650
-no
1&20
26.88
0
0
0
0
0
0
0
0
13A-0ocs
0.143
se
4.00
219
_._._0
__ _ 0_
__-_ 0
.... U
- _.. _0
___. _0
_ ___O
___ 0
11
2 glazing, clr low-e
0.650
as
18.20
21.07
0
0
0
0
0
0
0
0
2 glazing, clr lowe
0.650
se
18.20
22.59
0
0
0
0
0
0
0
0
�D
11DO _ _ _ __ ,
-- _0.390
_se
_10.92
10.34
0
0
0
0
0
0
0
V,V
13A-0ocs
0.143
sw
4.00
_
' 2A9
___ „
18
-� -__ .-0
18
__ _ _
72
_ - - 39
- - --54
- - ---54
- - 2106
_-_-G
2glazing, clr low-
.. .0.650
sw..__18.20
_ 21.07
.__ _ _0
._._0
_ ._ . 0
_
-0
__
0
w
13A-4ocs
0.143
nw
4.00
2.19
0
0
0
_.._0
0
__
0
.._._ ..0
0
._...0
0
_ ...
0
2 glazing, clr lowe
0.650
nw
18.20
26.88
0
0
0
0
0
0
0
0
_ _.
11DO _.
0.390
nw
_ 10.92
10.34
0
0
0
0
0
0
0
...
166-30ad__ . _
_._
_
_
.. __ 18
_ __
_ .18
_ _
_ _ 16
._ _ _ 29
_ _
_
. , _ -
54
-_ __0
-_
86
F
P _
22A-Iph _ . _ _
1.358
. _ _ 1.358
.- _
8.02
_ 38.02
0.00
_ 0,00
18
2
. _ .76
. - . 0
_ . .-54
54
. _
- _ 6
._ _ _.98
_ _228
. _ ..
. _ 0
6
c)AED excursion
J
-18
Envelope loss/gain
164
65
493
187
12
a) Infiltration
35
10
104
29
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
200
Subtotal Qms 6 to 13)
199
75
597
416
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
-199
-75
107
51
14
Subtotal
0
0
704
467
15
Duct loads
26%
46%
0
0
26%
45%
185
209
Total room load
0
0
889
676
Air required (cfm)
0
0
38
30
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
y*F wr19M1�oii- 2019-Apr.2913:17:40
EA Ri13 S N BEN ETTOl 2018 .n4) alc RSU08101 Page 2
...5 HOMES- 1820 8 MODEL- 5313 SAN BENDETTO PL.rup Calc = MJB Front Door faces: SE
wrightsoft' Right-J®Worksheet Job: 1820MODEL B
Entire House Date: Apr2922019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772466-6799 Fax: 772-466.6796 Email: OUICKCALCS@AOL.COM
1
2
3
Room name
Eglosed wall
Room height
BEDROOM 3
10.0 It
9.0 ft heaticool
CLST 3
3.0 ft
9.0 ft heat/cool
4
5
Room dimensions
Room area
13.0 x 10.0 ft
130.0 W
9.0 x 3.0 H
27.0 ft-
Ty
Construction
number
U-value
(BtuIVWF)
Or
HTM
(BtuNft2)
Area (ft')
or perimeter (8)
Load
(Btuh)
Area (ft')
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
N/PIS
Heat
Cool
6
11
I---G
93A-0ocs
2 glazing, clr Iow4-
2 A-4olg, clr low-e_
2 glazing, clr low-e
2 glazing, clr low-e
11DO -_ _ _
13A-flocs
0.143
0.650
_0.650
0.650
0.650
_ - 0.390
0.143
ne
rye
-ne
se
se
_se_
sw
. _._
4.00
18.20
- 18.20
18.20
18.20
- 10.92
4.00
- 2.19
28.88
_ _26.88
21.07
22.59
_ . 10.34
2.19
..- _...0-0
0
._. 0
0
0
_ 0
90
0
_-- 0
0
0
. 0
-- - 75
-_ 0
0
0
0
0
0
- 300
_0
0
0
0
0
0
-- 164
_ .0
0
0
0
0
_ 0
27
_-.. _...0
0
0
0
0
_ 0
27
_ ._ 0
0
0
0
0
_ 0
106
-0
0
---
0
0
0
- - -59
_. .
Uf!
.L--C
W
l--li
L:9
2glazing, clr lower..
13A-4ocs
2 glazing, clr low-e
11DO _ _
16B730ad . .. .. _
22A-top
_ _0.650
0.143
0.650
_0.390
_ ,0.032
_ 1.358
sw.
nw
nw
nw
-_
- _.
._1&20
4.00
18.20
10.92
` -
__0.90
.. 38.02
21.07
2.19
26.88
10.34
- -1.60
_ 0.00
_.15
0
0
- _. 0
.. 130
_ _ 130
_ . .7
0
0
0
__.__130
_ . _. 10
.273
0
0
_ 0
. 116
- - , 380
.. _.316
0
0
_ 0
.. 208
_.. _ 0
-0
0
0
0
_ _.27
- 27
... _0
0
0
-_ _ 0
._ .. 27
_ 3
_ ...0
0
0
_ 0
._. 24
_ _-. 114
__ _ _0
0
0
0
.__ 43
_ 0
C .
F,.
6
c)AED excursion
101
-5
Emelope lossfgam
1070
789
246
97
12
a) Infiltration
b) Room ventilation
173
0
49
0
52
0
15
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
600
0
Subtotal(lines 6to 13)
1244
1438
298
112
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
26%
45%
0
0
159
1402
368
0
0
72
1510
676
26%
45%
0
0
-298
0
0
0
0
-112
0
0
Total room load
Air required(cfm)
1770
76
2186
97
0
0
0
0
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
-1'}F wrrghtso^R- 2019-Apr-2913:17:40
I&-h RlghtSuite® Universal 201818.0.31 RSU08101 Page 3
...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: BE
wrightsoft' Right-JOWorksheet Job: 1820MODEL B
Entire House Date: Apr29,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM
1
Room name
AHU CLST
DINING ROOM
2
Biposed wall
0 ft
11.0 If
3
Room height
9.0 It heat/cool
9.0 it heat/ccol
4
Room dimensions
4.0 x 3.0 ft
20.0 x 11.0 H
5
Room area
12.0 ft'
220.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft')
Load
number
(Btuh/ft? °F)
(Btuh1ftj
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PIS
Heat
Coal
6
v -
13A:4ocs ._ _
___._.0.143
fie
-..:4.00
2A9
_ -. _0._
0
__ 0
__ _ 0
_ __ .0
. -0
___---0.._._.
------
-0
2 glazing, clrlowc
0.650
ne
18.20
26.88
0
0
0
0
0
0
0
-0
2 glazing,clr lowe
_. 0.040
ne_
_ 18.20..
28.88_
0
0_
0
0
0
13AAccs
0.143
se
4.00
2.19
_ _._0
0
0
__0_.-
0
_
0
_
0
0
__ _0
0
0
11
2 glazing, clr low-e
0.650
se
18.20
21.07
0
0
0
0
0
0
0
0
2 glazing, cir low-e
0.650
se
18.20
22.59
0
0
0
0
0
0
0
0
11D0 , _
0.390
se_
10.34
0
0
0
0-
0
0
_ _ _ _
Y-
_ ___.
13A-4ocs
,_ _
0.143
sw
__10.92
4.00
2.19
- _ _0
0
_ _ - --0
__. , -_0
0
-
- - 0
99
- -151
_
.
_
2 glazin clr low-e . _
- - -0.650
sw.
18.20
- 21.07
-_ -0
_._ 0
__.. _0
_ -0
... _ 30
_ .15
__ __ 546
_ ._ _ 632
vrl
13A-0ocs
0.143
nw
4.00
2.19
0
0
0
0
0
0
0
0
F�-CD
2 glazing, clr low-s
0.650
nw
18.20
26.88
0
0
0
0
0
0
0
0
11D0 ,- -_
_0.390
nw
10.92
10.34
0_
0
0
0
0
0
0
0
C. ...
166a0ad. _
._ 0.032
_-_
._0.90
-1.60
_ 12
_ .__12
_ ..
. _ . 11
_.. _
_ 19
_ ._
._.. _ 220
_
-
-_
_.. 197
_ .
F -
22A-tp - .
- .._
-___1.358
,-,
_38.02
_0.00
__12
_ _ 0
_0
_0
_.
..220
It.
_ _418
.352
0
6
c)AED excursion
_1
264
Emelope loss/galn
11
18
1438
1399
12
a) Infiltration
0
0
191
54
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6to 13)
11
18
1629
1453
Less eMemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
Al
-18
153
63
14
Subtotal
0
0
1782
1515
15
Duct loads
26%
45%
0
0
26%
45%
467
678
Total room load
0
0
2249
2194
Air required(cfm)
0
0
97
98
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
-}r- wrtgFi�so�PC- 2019-Apr-2913:17:40
AA RighlSuite® Universal 201818.0.31 RSU08101 Page 4
...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.mp Calc = MJ8 Front Door faces: SE
wrightsoft, Right-M Worksheet Job: 1820 MODEL B
Entire House Date: Apr29,2019
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCSo@AOL.COM
1
Room name
BEDROOM 4
CLST 4
2
2posed wall
24.0 ft
8.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heaVcool
4
Room dimensions
1.0 x 161.0 It
3.0 x 7.0 ft
5
Room area
161.0 IF
21.0 fl2
Ty
Construction
U-value
Or
HTM
Area (fl2)
Load
Area (ft2)
Load
number
(13tuh/ft2-°F)
(Btuhlf.)
or perimeter (f)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
134.4o6s - ._
. 0343
re
4.00
219
0
- 0
- .. - .0
-'0
-_ 45
_. ._ 45
__ 18o
.- _ 98
2 glazing, clr lower
0.650
ne
18.20
26.88
0
0
0
0
0
0
0
0
2 glazing, clr lower -
_ 0.650
ne_
26.BB
0
0
0
0
0
0
0
0
13A4ocs
0.143
se
..18.20
4.60
__
2.19
_ _
99
_ _
69
., _-.. _
278
-
151
_ _
27
_
- 27
_ _
168
59
11
2 glazing, clr low-e
0.650
se
18.20
21.07
30
15
546
632
0
0
0
0
2 glazing, clr Im-e
0.650
se
18.20
22.59
0
0
0
0
0
0
0
0
11D0 __ -
0.390
se-
10.92
10.34
0
0
0
0
0
0
0
0
13A-4ocs
0.143
sw
_
4.00
2.19
- - 117
117
- -- 468-
256
- - - 0
- 0
- - - 0
- 0
2 glazing, clr low-e _
0.650
sw
18.20
21.07
- 0
0
. 0
.0
0
_ _ .0
.0
.0
0.143
nw
4.00
2.19
0
0
0
0
0
0
0
0
L13A-0acs
�D
2 glazing, clr low-e
0.650
rw
18.20
26.88
0
0
0
0
0
0
0
0
_
11DO _
0.390
nw
10.92
10.34
0
0
0
0
0
0
0
0
C
16Mad- -
_ _ 0.032
-
_ _ 0.90
1.60
161
_
161
- _ 144
_
258
_
21
21
19
34
F
22A-toh _ -
_ 1.358
38.02
0.00
161
24
_ 913
_..
0
_
21
8
_ _
304
- _ 0
6
c) AED excursion
105
-9
Emelope loss/gain
2348
1402
611
182
12
a) Infiltration
416
117
139
39
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2764
1519
750
221
Less Warm] load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
625
184
-750
-221
14
Subtotal
3389
1703
0
0
1151
Duct loads 1
269/6
45%
889
763
26%
45%
0
0
Totiral room load
4278
2466
0
0
Arequired (cfm)
184
110
0
0
Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed
- wrlghtsoft- 2019-Apt.2913:17:40
AM, RightSuiteO Universal 201818.0.31 RSU08101 Page 5
...5 HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.rup Colo = Mill Front Door faces: SE
wrightsoft• Right-J® Worksheet Job: 1820 MODEL 8
Entire House Date: Apr29,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM
i
2
3
4
5
Room name
F)posed wall
Room height
Room dimensions
Roam area
FOYER
6.0 ft
9.0 It heat/cool
6.0 x 8.0 0
48.0 ft2
LAUNDRY
0 ft
9.0 It heatfcool
7.0 x 7.0 it
49.0 ft2
Ty
Construction
number
U-value
(Btuf✓ft' °F)
Or
HTM
(Btuhlft2)
Area (ft2)
or perimeter (ft)
Load
(Bluh)
Area (ft2)
or perimeter (0)
Load
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
NIP/S
Heat
Cool
6
11
Val
�C
13A=flocs "_.. _
2 grazing, clr lowe
2 glaring, clr Iowa -
13A-4ocs _
2 glazing, clr Iowa
2 glazing, clr Iowa
11D0� _
13A'13cs
2 glazing, ciclava _
'a
2 glazing, clr lowe
11DO _., -
_ . _ -
22A-tph-_ __ _
- -' 6.143
0.650
0.650
..0.143
0.650
0.650
_ 0.390
0.143
_ .._ 0.650
0.143
0.650
_-0.390
1.358
1.358
fie
ne
re
�as
as
as
_se
sw
sw..
my
my
my
, -
=
4.00
18.20
1820
406
1820
18.20
_ 10.92
4.00
.. _18.20
4.00
18.20
- 10.92
0.00
38.02
..2:19
26.88
26.88
.2.19..
21.07
22.59
_ _10.34
2.19
...21.07
2.19
26.88
10.34
_'1.00
0.00
. _. _ 0
-0
0
_.54
0
13
20
_... 0
_ . _ .0
0
0
0
_ _ _ _ 48
48
. _..__0
0
0
_ _. 21
0
5
20
... 0
__ _ 0
0
0
_-_0
._ _... _48
6
_ 0
0
0
82
0
244
- 219
0
.. .. 0
0
0
- __ 0
... _ 43
228
------0
0
0
45
0
303
208
_ _ . 0
._ _._ 0
0
0
- 0
77
- 0
_ .. _0
0
0
.__. _ _0
0
0
_ 0
.. 0
_ _ _ 0
0
0
-0-
_ 49
49
_ . __ 0
0
0
._ __.0
0
0
0
-._0
_ .. .0
0
0
-_0
_ . __ 49
0
_ .. _0
0
0
_.__d
0
0
_ 0
.. 0
__ .0
0
0
0.
_ 44
0
. -0
0
0
_ _ ..0
0
0
0
_ __ 0
. _ _ -0
0
0
0
- 0
_ _ _78
- , _ 0
_
W,
VLZliA
_
F16B30ad-
F _,.
6
c)AED mursion
59
-32
F_melope loss/gain
817
691
44
46
12
a) Infiltration
b) Room ventilation
104
0
29
0
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
700
Subtotal (lines 6to 13)
921
720
44
746
14
15
Less eldemal load
Less transfer
Redistribution
Subtotal
Duct loads
26%
450A
0
0
125
1046
274
0
0
37
757
339
26%
45%
0
0
0
44
12
0
0
0
746
334
Total room load
Airrequired(cfm)
1320
57
1096
49
55
2
1081
48
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
A -r}f wrlgtiisoT2- 2019-Apr-29 13:17:40
RighlSuite® Unly rsal 201818.0.31 RSU08101 Page 6
...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJB Front Door faces: SE
1 wrightsoft Right-JO Worksheet Job: 1820MODELB
Date: Apr 29, 2019
Entire House
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fa�c 772466-6796 Email: OUICKCALCS@AOL.COM
1
Room name
KITCHEN
FAMILYROOM
2
3
Exposed wall
Room height
16.0 It
9.0 0 heatlowl
13.0 ft
9.0 ft heat/cml
4
5
Room dimensions
Room area
1.0 x 2620 ft
262.0 fP
1.0 x 264.0 ft
264.0 ft'
Ty
Construction
U-value
Or
HTM
Area (f')
Load
Area (f8)
Load
number
(Btuh/0'-°F)
(Btulvft�
or perimeter (f)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Grass
N/P/S
Heat
Cool
Gross
N/PIS
Heat
Caol
6
11
1--G
13A7-4obs -
2 glazing, clr lowe
2 glazing,, clr I=7e -
13A-0ocs
2glazing, clr low-e
2 glazing, clr lcwe
11D0 ,_ ._ _ _
13A-0ocs
2glaztrg,.clrlow-e._ .._
13A-4ocs
0.143
0.650
,0.650
0.650
O.fi50
0.650
_. __0.390
0.143
_-.0.650
0.143
re
ne
na
as
se
as
_ se.
sw
sw.
nw
.--.4.00
18.20
.1820
1820
420
1820
1092
4.00
...18.20
4.00
`- 2.19
26.88
26.88
1.07
21.07
2259
_. 10.34
2.19
_... 21.07.
2.19
_. --144
0
_ 30
'. 0
0
0
_ _. _ 0
0
_ _ .0
0
iib
0
0
0
0
0
_.___ __0
0
. _ _. 0
0
___--456
0
546
- __. .0
0
0
_ _0
0
_0
0
249
0
806
.,_ 0
0
0
_ _ .-0
- 0
_ _ 0
0
__ _. .0
0
0
_. .. _0,
0
0
_ _ __ 0
-'0
_- .__.0
117
.__ __ 0
0
0
_. .. e_ 0._._
0
0
_ _ 0
0
- 69
----..,0
0
__._0
0
0
0
_ ._ 0.
0
277
_ �.0
0
0
_._ _ .0
0
0
__. ._ 0
0
- -151
vf/
�(GD
Lt.
IN
2 glazing, clr lowe
11D0 - - _ _
168-36ad
0.650
0.390
0.032 _
rnv
nw
-
18.20
10.92
..
_ 0.90
26.88
10.34
...
_1.60
0
_ 0
_ 262
0
0
..... 262
0
_ _ - 0
235
0
_ _ 0
419
30
18
. 264
0
-18
546
_ 795
806
_ _ 185
422
_
C
F-_
22A tph
1.358
_ r
38.02
y0.00
_ - _ 262
_ ._ 1_6
_ _
_. 608
.._
- 0
_ ._ 264
__264
13
_ ...237.
. _. 494,
- _ _.
._ 0
6
c)AED excursion
-130
156
Envelope loss/gain
1846
1345
1749
1721
12
a) Infiltration
278
78
226
64
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
1600
1200
Subtotal (lines 6to 13)
2123
3023
1974
2984
Less e)demal load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
0
2123
0
0
3023
0
13
19W
0
23
3007
15
Duct loads
26%
45%
W7
1354
26%
45%
522
1347
Total room load
2680
4377
2509
4354
Air required (cfm)
115
195
108
194
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
=Lle lsan- 2019-Apr-29 13:17:40
.4•C�'A Ri13 S N BE Universal 2018 .n4) alc RMJB F 7 Page 7
...6 HOMES- 1820 B MODEL- 5313 6AN BENDETTO PL.rup� Calc = MJ8 Front Door (aces: 8E
wrightsofr Right-M) Worksheet Job: 1820 MODEL B
Entire House Date: Apr29,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1VRwm
HALL
O BATH
2ll
0 It
11.9 ft
3t
9.0 ft heat/cocl
9.0 ft heaUcool
4nsions
4.0 x 8.0 ft
1.0 x 130.5 ft
5
32.0 W
130.5 fN
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area (ft')
Load
number
(Btuh/ft' °F)
(Btuhlf .)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
.0343
ne
4.00
.. _219
_ ---0
_. _ --0
0
. _0
_.-108
-LL.. _-102
"` __.�8
._. _ 223
IL-GG
2 glazing, clr Iowa
0.650
ne
18.20
26.88
0
0
0
0
6
0
109
161
•
2 glazng,.clrlow-e
.._ 0_650
ne:
1820
26.88
_.._ 0
0
0
0
0
0
0
___. -
13A-0acs
0.143
se
400
2.19
0
�. _ 0
_ _0.
U
_ __ _._0
. ___0
. 0
.0
.. .0
11
2 glazing, clr Iowa
0.650
se
18.20
21.07
0
0
0
0
0
0
0
0
2 glazing, clr Iowa
0.650
se
18.20
22.59
0
0
0
0
0
0
0
0
_ _
11D0 , . _ _ __
_ 0.390
se_
�sw
10.92
10.34
0
0
0
0
0
Wi
93A-0ocs
_
0343
___4.00
� _. 2.19
-_� _.0
_..�
0
_ ._.
0
- .. _ 0
_.._. __0
.-0
0
- _.0
_ 0
. _---G
2 glazing, clr Iowa_
__ 0.650-sw.
-18.20
__21.07
._. _.. 0_.__......._0
-_.0...
.. _0
._.. _.0
.. ._..:0
0
13A-flocs
0.143
nw
4.00
2-19
0
0
0
0
0
0
_ .___0
0
_
0
2 glazing, clr Iowa
0.650
nw
18.20
26.88
0
0
0
0
0
0
0
0
11D0 _ _
_ 0.390
nw-
10.92
10.34
0
0
0
0
0
0
0
0
_
'C _
16B30ad, -. ---,
_ _0.032
r
_ 0.90
.-- 1.60
_ _
_.32
. - �32
_- _ 29,
,51
_
_117
_
F _
22A-tph ._ .
1.358
-
38.02
0.00
---32
_0
0
_0
----131
131
_._ _131
_ _ . 12
_-
....453
- ,200
._ _ _..0
6
c)AED excursion
-2
-37
Envelope loss/gain
29
49
1088
556
12
a) Infiltration
0
0
208
59
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants Q 230
0
0
0
0
Apqianceslother
0
250
Subtotal (lines 6to 13)
29
49
1296
865
Less exdemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
-29
-49
0
0
14
Subtotal
0
0
1296
865
15
Duct loads
26%
45-A
0
0
26%
45%
340
387
Total room load
0
0
1836
1252
Air required (cfm)
0
0
70
56
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
-}/- wrigh,�oft- 2019-Apr.2913:17:40
149& RightSulte® Universal 201818.0.31 RSU08101 Page 8
...S HOMES. 1820 B MODEL- 5313 SAN BENDETTO PL.mp Cato = MJ8 Front Door faces: SE
wrightsoft' Right-J®Worksheet Job: 1820 MODEL
Entire House Date: Apr29,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
E:yxrsad wall
Room height
Room dimensions
Room area
O WIC
0 8
9.0 ft heaVcocl
1.0 x 37.5 it
37.5 ft2
OWNERSBEDROOM
40.0 ft
9.0 0 heat/cool
14.0 x 16.0 It
224.0 ft'
Ty
Construction
number
U-value
stultlf W)
Or
HTM
(Btuh/ftg
Area (ft')
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(8tuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Y�1'
1-G
13A-06cs -
2 glazing, clr Iowa
2glazirg; cfrlow-e _
13A-4ocs
2 glazing, clr Iowa
2 glazing, clr Iowa
11D0 _
13A46cs7
2glazing, cir Iowa . _
13A-0acs
2 glazing, clr Iowa
12 _
IS _
22A_toh _ - _
0143
0.650
0.650
0.149
0.650
0.650
_0.390
0.143
.__ 0.650
0.143
0.650
_ 0.390
_ _1.358
_ _ _ 1.358
ne
ne
ne
se
se
se
se
sw
_sw.
nw
nw
nw
_. -
. -
. -74.00
1020
18.20
4.06
18.20
18.20
-, 10.92
4.00
. .:18.20
4.00
18.20
10.92
_._0.90
38.02
-- 2.19
26.88
_ 26.88
2.19
21.07
22.59
-10.34
_ _2.19
_21.07
2,19
26.88
_ 10.34
_ 1.60
_ 0.00
_ ---0
0
0
0
0
0
_ _ _0
0
_ .: . 0
0
0
0
. ._ 38
_ -38
__ _ . 0
0
_ 0
0'
0
0
_ - -_0
� 0
_.. -. 0
0
0
0
_. _ 38
_ 0
..._ _..-0
0
___ 0
_0
0
0
_ -, - 0
0
_ 0
0
0
0
34
- _ _ 0
._.. _ _ -0
-0
___-- 0
0
0
0
0
--.- -0
. __ _0
0
0
0
_ -60
- _ _0
......1m
0
_ _ _15
� 0
0
0
0
- OD
. ..-0
126
15
0
_224
- 224
... ..129
0
_ 0
0
0
0
0
� -�90
_ _ .0
111
0
0
_ __.224
_ 40
._--- 517
0
-___27.3
0
0
0
_ _ _ 0
360
_. __ _0
444
273
_ 0
_ _. 201'..
1521
.. _ 2B2
0
4.03
___
6
0
0
_ 0
� � 707
243
403
_ 0
_ 358
0
V7!
{L-----GD
_._..
_
C
F _
6
c)AED excursion
-2
89
Ernelope losslgam
34
58
3589
1818
12
a) Infiltration
b) Room ventilation
0
0
0
0
694
0
196
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
900
Subtotal (lines 6 to 13)
34
58
4283
2914
14
15
Less eldemal load
Less transfer
Redistribution
Subtotal
Duct loads
26%
45%
0
0
0
34
9
0
0
0
58
26
26%
46%1
0
0
0
4283
1124
0
0
0
2914
1305
Total room load
Air required (cfm)
42
2
83
4
5407
232
4218
188
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
-rw wr�gh�oR- 2019-Apr-2913:17:40
Ri13 S N BEN niversa12 .ru 18Calc RMJ8 F 1 Page 9
...5 HOMES- 1820 B MODEL- 5313 SAN BENDErfO PL.rup Calc = MJe Front Door faces: SE
wrightsoft Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM
Project Information
For. ADAMS HOMES
5313 SAN BENDETTO PLACE, FORT PIERCE, FL
Extemal static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
in/10Dft
1167
cfm
180
Job: 1820 MODEL B
Date: Apr29,2019
By:
Cooling
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
iN100ft
1167
cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
CIg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH 2
h 889
38
30
1.000
5.0
OX0
VIFx
15.7
115.0
SO
BEDROOM 2
h 4356
187
98
1.000
7.0
OX0
VIFx
21.7
115.0
st1
BEDROOM 3
c 2186
76
97
1.000
7.0
OX0
VIFx
18.9
115.0
st1
BEDROOM 4
h 4278
184
110
1.000
7.0
OX0
VIFx
21.6
115.0
st3
DINING ROOM
c 2194
97
98
1.000
7.0
OX0
VIFx
20.4
115.0
st3
FAMILY ROOM
c 2177
54
97
1.000
7.0
OX0
VIFx
15.8
115.0
st1
FAMILY ROOM -A
c 2177
54
97
1.000
7.0
OX0
VIFx
17.1
115.0
st1
FOYER
h 1320
57
49
1.000
6.0
OX0
VIFx
19.9
115.0
st3
KITCHEN
c 2189
56
98
1.000
7.0
OX0
VIFx
27.2
115.0
st2
KITCHEN -A
c 2189
58
98
1.000
7.0
OX0
VIFx
25.2
115.0
st2
LAUNDRY
c 1081
2
48
1.000
6.0
OX0
VIFx
23.6
115.0
st3
DBATH
h 1636
70
56
1.000
6.0
OX0
VIFx
23.0
115.0
st2
OWIC
c 83
2
4
1.000
4.0
OX0
VIFx
43.8
135.0
st4
OWNERS BEDROOM
h 2703
116
94
1.000
7.0
OX0
VIFx
40.3
135.0
st4
OWNERS BEDROOM -A
h 2703
116
94
1.000
7.0
OX0
VIFx
44.7
135.0
1 SW
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st4
PeakAVF
234
192
1.000
670
8.0
0 x 0
VinIFIX
st2
st2
PeakAVF
419
443
1.000
671
11.0
0 x 0
VinlFlx
st3
PeakAVF
339
305
1.000
768
9.0
0 x 0
VinlFlx
SH
PeakAVF
409
419
1.000
636
11.0
0 x 0
VinlFlx
wrightsoft' tots-Apr-2s 13: t7:at
CA •�»•� •- -.•-+. RightSuiteS, Universal 201818.0.31 RSUD8101 Page 1
...S HOMES. 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: BE
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
ox0
1167
1167
0
0
0
0
Ox 0
VIFx
wrightsoft' 2019-Apr-2913:17:41
•�+ •�—+�-+-, Right -Suite® Universal 201818.0.31 RSU08101 ,Page 2
'�` ...S HOMES- 1820 B MODEL-5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: SE