Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE'FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODM ILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES- 1820 B MODEL Builder Name: ADAMS HOMES SCANNED Street: 5313 SAN BENDETTO PLACE Permit Office: ST LUCIE COUNTY BY City, State, Zip: FORT PIERCE, FL, Permit Number: St-. Lucia onlingy Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1890.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- EM Insul, Exterior R=4.1 1656.00 ft2 b. Frame- Wood, Adjacent R=11.0 234.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= 112 5. Is this a worst case? No 10. Ceiling Types (1820.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(199.3 sgft.) Description Area a. Sup: Attic, Ret Attic, AH: AHU CLST 6 150 a. U-Factor: Sgl, U=0.65 186.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 13.33 fN 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 35.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 27.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.253 14. Hot water systems 8. Floor Types (1820.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features EF: 0.900 b. N/A R= ft2 None c. N/A R= W 15. Credits None Glass/Floor Area: 0.110 Total Proposed Modified Loads: 61.75 PASS Total Baseline Loads: 63.87 1 hereby certify that the plans and specifications covered by Review of the plans and Srq?� this calculation are in compliance with the Florida Energy specifications covered by this QFTNg Code. calculation indicates compliance yk3 ,, '. °„ with the Florida Energy Code. nw2•; ;'::ice;>. O PREPARED BY: Y: Before construction is completed DATE: 4-2 this building will be inspected for compliance with Section 553.908 1:4 a r e I�iereby certify that this building, as designed, is in Florida Statutes. 9� with the Florida Energy Code. COp WE OWNER/Ar-' , �Yi " ` BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/29/2019 1:32 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ADAMS HOMES- 1820 B MO Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1820 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5313 SAN BENDETTO Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1820 16380 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM2 130 1170 No 0 1 1 Yes Yes Yes 2 CLST 2 17 153 No 0 1 Yes Yes Yes 3 BATH 2 54 486 No 0 1 Yes Yes Yes 4 BEDROOM 3 130 1170 No 0 1 1 Yes Yes Yes 5 CLST 3 27 243 No 0 1 Yes Yes Yes 6 AHU CLST 12 108 No 0 1 No Yes Yes 7 DINING ROOM 220 1980 No 0 1 Yes Yes Yes 8 BEDROOM 4 161 1449 No 0 1 1 Yes Yes Yes 9 CLST 4 21 189 No 0 1 Yes Yes Yes 10 FOYER 48 432 No 0 1 Yes Yes Yes 11 LAUNDRY 49 441 No 0 1 No Yes Yes 12 KITCHEN 262 2358 Yes 0 1 Yes Yes Yes 13 FAMILY ROOM 264 2376 No 0 1 Yes Yes Yes 14 HALL 32 288 No 0 1 No Yes Yes 15 0 BATH 131 1179 No 0 1 Yes Yes Yes 16 0 WIC 38 342 No 0 1 No Yes Yes 17 OWNERS BEDRO 224 2016 No 0 1 1 Yes Yes Yes 4129120191:32 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 33 ft 0 130 ft2 -___ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 17 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 54 W ____ 1 0 0 4SIab-On-Grade Edge Insulation BEDROOM 10ft 0 130W ---- 1 0 0 5SIab-On-Grade Edge Insulation CLST 3 3 ft 0 27 W -- 1 0 0 6SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 12 ft2 ___ 1 0 0 7SIab-On-Grade Edge Insulation DINING ROOM 11 ft 0 220 ft2 ____ 1 0 0 8SIab-On-Grade Edge Insulation BEDROOM 4 24 ft 0 161 ft. -- 1 0 0 9SIab-On-Grade Edge Insulation CLST 4 8 ft 0 21 ft2 _-__ 1 0 0 10SIab-On-Grade Edge Insulation FOYER E ft 0 48 ft' ____ 1 0 0 11SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 49 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 16 ft 0 262 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation FAMILY ROOM 13 ft 0 264 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ____ 1 0 0 1551ab-On-Grade Edge Insulation O BATH 11.9 it 0 131 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation OWIC 1ft 0 38 ft2 1 0 0 17SIab-On-Grade Edge Insulation OWNERS BEDR 40 It 0 224 ft2 -- 1 0 0 ROOF / Roof Gable Roof Solar SA Emilt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2035 ft2 0 ft2 Medium 0.6 No 0.9 No 0 26.6 ATTIC / `� # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 fl2 N N 4/29/20191:32 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 130 ft2 0.1 Wood 2 Under Attic (Vented) CLST 2 30 Blown 17 ft2 0.1 Wood 3 Under Attic (Vented) BATH 30 Blown 54 ft2 0.1 Wood 4 Under Attic (Vented) BEDROOM 30 Blown 130 ft2 0.1 Wood 5 Under Attic (Vented) CLST3 30 Blown 27 ft2 0.1 Wood 6 Under Attic (Vented) AHU CLST 30 Blown 12 fP 0.1 Wood 7 Under Attic (Vented) DINING ROOM 30 Blown 220 ft2 0.1 Wood 8 Under Attic (Vented) BEDROOM 4 30 Blown 161 W 0.1 Wood 9 Under Attic (Vented) CLST4 30 Blown 21W 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 48 ft2 0.1 Wood it Under Attic (Vented) LAUNDRY 30 Blown 49 ft2 0.1 Wood 12 Under Attic (Vented) KITCHEN 30 Blown 262 ft2 0.1 Wood 13 Under Attic (Vented) FAMILYROOM 30 Blown 264 ft2 0.1 Wood 14 Under Attic (Vented) HALL 30 Blown 32 ft2 0.1 Wood 15 Under Attic (Vented) 0 BATH 30 Blown 131 ft2 0.1 Wood 16 Under Attic (Vented) OWIC 30 Blown 38 ft2 0.1 Wood 17 Under Attic (Vented) OWNERS BEDR 30 Blown 224 fN 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE Exterior Concrete Block - Ext InsiBEDROOM 2 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0 2 SW Exterior Concrete Block - Ext InstBEDROOM 2 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0 _ 3 NW Exterior Concrete Block - Ext InstBEDROOM 2 4.1 13 0 9 0 117.0 ft2 0 0 0.6 0 4 SW Exterior Concrete Block- Ext Insul CLST 2 4.1 2 0 9 0 18.0 ft2 0 0 0.6 0 5 SW Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 9 0 54.0 fl2 0 0 0.6 0 6 SW Exterior Concrete Block - Ext InstBEDROOM 3 4.1 10 0 9 0 90.0 ft. 0 0 0.6 0 7 SW Exterior Concrete Block - Ext Insul CLST 3 4.1 3 0 9 0 27.0 W 0 0 0.6 0 8 SW Exterior Concrete Block - Et InsOINING ROO 4.1 11 0 9 0 99.0 ft. 0 0 0.6 0 9 BE Exterior Concrete Block- Ext Ins51EDROOM 4 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0 10 SW Exterior Concrete Block -Ext lnstSEDROOM4 4.1 13 0 9 0 117.0ft2 0 0 0.6 0 11 NE Exterior Concrete Block- Ext Insul CLST 4 4.1 5 0 9 0 45.0 fl2 0 0 0.6 0 12 BE Exterior Concrete Block - Ext Insul CLST 4 4.1 3 0 9 0 27.0 ft2 0 0 0.6 0 13 SE Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0 _14 NE Garage Frame - Wood FOYER 11 6 0 9 0 54.0 ft2 0 0.25 0.6 0 Ilk 15 SE Garage Frame -Wood LAUNDRY 11 7 0 9 0 63.0 f12 0 0.25 0.6 0 16 NE Exterior Concrete Block- Ext Insul KITCHEN 4.1 16 0 9 0 144.0 f12 0 0 0.6 0 17 SE Garage Frame -Wood KITCHEN 11 13 0 9 0 117.0W 0 0.25 0.6 0 18 NW Exterior Concrete Block- Ext lnsOAMILY ROO 4.1 13 0 9 0 117.0 f12 0 0 0.6 0 19 NE Exterior Concrete Block- Ext Insul 0 BATH 4.1 12 0 9 0 108.0 ft2 0 0 0.6 0 _20 NE Exterior Concrete Block -Ext lnsOWNERS BE 4.1 16 0 9 0 144.0 ft2 0 0 0.6 0 21 SW Exterior Concrete Block -Ext InsOWNERS BE 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0 22 NW Exterior Concrete Block -Ext InsOWNERS BE 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0 4/29/2019 1:32 PM EnergyGaug& USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPf)RT DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 SE NW Insulated Insulated FOYER None FAMILY ROO None .39 3 .39 2 8 6 8 6 8 20 ft2 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening _ 1 2 3 4 5 6 _ 7 8 9 10 NW 3 Metal SW 6 Metal SW 8 Metal SE 9 Metal SE 13 Metal NE 16 Metal NW 18 Metal NE 19 Metal NE 20 Metal NW 22 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.7 0.3 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 15.0 ft- 2 ft 0 in 1 ft 4 in 15.0 ft2 2 ft 0 in 1 ft 4 in 30.0 ft2 2 ft 0 in 1 ft 4 in 30.0 ft2 2 ft 0 in 1 fl4 in 13.3 ft2 2 ft 0 in 1 ft 4 in 30.0 ft2 2 ft 0 in 1 ft 4 in 30.0 ft2 2 ft 0 in 1 fl4 in 6.0 ft2 2 ft 0 in 1 fl4 in 15.0 ft2 2 ft 0 in 1 ft 4 m 15.0 ft2 2 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1911 104.91 197.3 .3005 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit' Split SEER: 15 35 kBtu/hr 1050 cfm 0.8 1 sys#1 ` HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60.9 gal 120 deg None 4/29/2019 1:32 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply— •-- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 W Attic 15 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable[[T��hermostat::[ Ceiling Fans: ]]N Venting [X) Jan [X] Feb f[X],] [ ] Mar [ ] Apr [XJ [ ] Jun [X� [ ] Jul D0 [ ] Aug [X] [ ] Sep [[X�] Nov Nov Dec Decec Venting [[ 11 Jan II 11 Feb IXl lxl Mar [XI May I 1 Jun [ 1 Jul I 1 Aug [) Sep Oct [X] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WO) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 HeaBng(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft, ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft, ft 0.3 CLST 3 Default(8 lbs/sgJt. ft2 ft 0.3 AHU CLST Default(8 lbs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST4 Default(81bs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 FAMILYROOM Default(8 lbs/sq.ft. ft2 ft 0.3 HALL • Default(8 lbs/sq.ft. ft2 ft 0.3 O BATH Default(8 lbs/sq.ft. ft2 ft 0.3 O W IC Default(8 lbs/s.ft. ft2 ft 0.3 OWNERS BEDRO ' Name: Rating Compant: Date: 4-29-19 4/29/2019 1:32 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1820 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.653 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.253 14. Heating system: Capacity 27.0 c) Area 7c. 199.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heal Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signa � e � - t1 Date: 1 I25 I ( c1 Address of New Home: 5313 SAN BENDETTO PLACE City/FL Zip: FORT PIERCE, FL 4/29/2019 1:32:51 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ST LUCIE COUNTY Permit #: Job Information Builder: ADAMS HOMES Community: Lot: NA Address: 5313 SAN BENDETTO PLACE City: FORT PIERCE State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The building or dwelling, unit shallbe tested and verified as having an air leakage rateof not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 Pascals) in Climate Zones 1 and 2. Q PERFORMANCE or ERI METHOD-Thebuilding or dwelling unit shall betested and verified as,having an air leakage rate of not exceeding - the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Calc.(Performance) or R406-2017 (ERQ; Z000 ; x 60 = 16380 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS Code 0 software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode of bial. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the lest, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 4/29/2019 1:33:20 PM EnergyGauga USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project SummaryJob: 1820MODELB wrightsoft' Entire House DDate: Apr29,2019 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fm 772466,6796 EnraiC OUICKCALCS@AOL.COM Project Information For. ADAMS HOMES 5313 SAN BENDETTO PLACE, FORT PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21540 Btuh Structure 18080 Btuh Ducts 5652 Btuh Ducts 8096 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27192 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24867 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4281 Btuh Ducts 2194 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Cool' (none) (ft�) 1820 1820 Equipment latent load 6475 Btuh Volume (ft3) 16380 16380 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 31342 Btuh Equiv. AVF (cfm) 104 55 Req, total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3600GOBO Cond CH14NBO3600GOBO AHRI ref 9162518 Coil FX4DNF049L AHRI ref 9162518 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24500 Btuh Heating output 34000 Btuh @ 477 Latent cooling 10500 Btuh Temperature rise 27 OF Total cooling 35000 Btuh Actual airflow 1167 cfm Actual airflow 1167 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point = 36 OF Backup: Input = 7 kW, Output = 24822 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed -rk- =rights ft- 2019-Apr-29 13:17:40 RlghtSuite® Universal 2018 18.0.31 RSU08101 -� ...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.nip Calc = MJ8 Front Door faces: SE Page 1 wrightsoft' Right-M Worksheet Job: 1820 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: OUICKCALCS@AOL.COM 1VRm me Entire House BEDROOM 2 2 3ight wall 183.9 It 9.0 ft 33.0 It 9.0 ft heat/cool 4mensions 5rea 1820.0 ft' 13.0 K 10.0 If 130.0 fl' Ty Construction number U-value (Btuh/WF) Or HTM (Btuh/ftj Area (w) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 I-G 13A4oc9 2 glazin cir lowe 2 glazrtg, clr lave 13A-0acs 2 glazing, cir low-e 2 glazing, cir lowe ___._ 13A flocs - _0:143 0.650 _ _ 0.650 0.143 0.650 0.650 _ _ 0.390 0.143 -rle- ne _ ire_ se se se _se_ sw ..- 4.00 18.20 1820 406 18.20 1820 10.92 - -4.00 2.19 26.88 26.88 2.19 21.07 22.59 _,_10.34 2.19 .".-331 6 _ _ _ 45 180 30 13 20 585 ..-.__480 0 _.._ __ 0 117 15 5 _20 540 _.__..1922.. 109 819 -4-66 546 244 _ _ _ 219 2162 _.._.ice 161 1209 ---255- 632 303 208 - 1181 _.._._ 90 0 0 0 0 0 _ _ 0 �90 _- _..90 0 0 -- -- p 0 0 0 _ _90 _... __.360 0 0 --- 0 0 0 0 _ .. _ _3w 197 0 0 - �--0 0 0 0 - -197 V)J F�-ffD' V+/ - G 2 glazing. cir lowe 13A-4ocs ,__. 0.650 0.143 .sw rw __18.20 4.00 .21.07 2.19 _._..__45 360 ____22 282 ____819 1130 _. __948 617 _. _ __ -.0 117 _ - _.0 102 . _-_-0._---- 408 _.0 223 __ _ C_ .. _ 2 glazing, clr lowe 11DO _ . . ._ 16B30ad. _ _ 0.650 _ _0.390 ..0.032 mw rw _ - 18.20 10.92 _..0.90 26.88 _10.34 1.60 60 _ 18 .v_ 1820 0 _ __ 18 _ _. 4820 1092 __ 195 . _. 7631 1613 185 �- .2912 15 0 - 130 0 _ .. 0 . _ .130 273 _ . 0 403 _ _ _ 0 .. 208 22Q_toh _ _ _ _ _ _ _ 1.358 - . 38.02 _ U0 _ 1820 . __ 184 _ _ _ 6993 _ _ 0 ._ _ 130 33 _ _116 1255 _ 0 6 c) AFJD excursion 456 79 Emelope loss/gain 18348 11730 2773 1307 12 a) Infiltration 3192 900 573 161 b) Room ventilation 0 0 0 0 13 Internal gans: Occupants @ 230 0 0 0 0 Appliances/other 5450 0 Subtotal Qines 6to 13) 21540 18080 3346 1469 Less e#emal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 21540 0 0 18080 0 105 3451 0 46 1515 15 Duct loads 26% 45% 5652 8096 26% 45% 905 678 r187 Total mom load 27192 26176 4356 2193 PJr required (cfm) 1167 1167 98 Calculations aooroved bvACCA to meet all reauirements of Manual J 8th Ed -+}r- wr19�+�so4ft- 2019-Apr-2913:17:40 A RlghtSuite® Universal 2018 18.0.31 RSU08101 - Page 1 ...S HOMES. 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: SE wrightsoft, Right-J@ Worksheet Job: 1820 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name CLST 2 BATH 2 2 E)posed wall 2.0 It 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 0 heat/cool 4 Room dmensions 9.0 x 20 it 9.0 x 6.0 ft 5 Room area 18.0 ft' 54.0 W Ty Construction U-value Or HTM Area (ft') Load Area (ft-) Load number (Btuh/ftMF) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Coot Gross N/P/S Heat Cool 6 13A-00c§ _ .. .__ _. 0.143 , ne- _ . _4.00 "219 _0 . .0 .. _....0 _ _ . _ _.0 _ _ __0 0 ._. _ 0 0 t�-GG 2 glazing, co- lowe 0.650 m 1820 26.88 0 -0 0 0 0 0 0 0 2 glazing, clr low- _- .__ 0.650 -no 1&20 26.88 0 0 0 0 0 0 0 0 13A-0ocs 0.143 se 4.00 219 _._._0 __ _ 0_ __-_ 0 .... U - _.. _0 ___. _0 _ ___O ___ 0 11 2 glazing, clr low-e 0.650 as 18.20 21.07 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 se 18.20 22.59 0 0 0 0 0 0 0 0 �D 11DO _ _ _ __ , -- _0.390 _se _10.92 10.34 0 0 0 0 0 0 0 V,V 13A-0ocs 0.143 sw 4.00 _ ' 2A9 ___ „ 18 -� -__ .-0 18 __ _ _ 72 _ - - 39 - - --54 - - ---54 - - 2106 _-_-G 2glazing, clr low- .. .0.650 sw..__18.20 _ 21.07 .__ _ _0 ._._0 _ ._ . 0 _ -0 __ 0 w 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 _.._0 0 __ 0 .._._ ..0 0 ._...0 0 _ ... 0 2 glazing, clr lowe 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 _ _. 11DO _. 0.390 nw _ 10.92 10.34 0 0 0 0 0 0 0 ... 166-30ad__ . _ _._ _ _ .. __ 18 _ __ _ .18 _ _ _ _ 16 ._ _ _ 29 _ _ _ . , _ - 54 -_ __0 -_ 86 F P _ 22A-Iph _ . _ _ 1.358 . _ _ 1.358 .- _ 8.02 _ 38.02 0.00 _ 0,00 18 2 . _ .76 . - . 0 _ . .-54 54 . _ - _ 6 ._ _ _.98 _ _228 . _ .. . _ 0 6 c)AED excursion J -18 Envelope loss/gain 164 65 493 187 12 a) Infiltration 35 10 104 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 200 Subtotal Qms 6 to 13) 199 75 597 416 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -199 -75 107 51 14 Subtotal 0 0 704 467 15 Duct loads 26% 46% 0 0 26% 45% 185 209 Total room load 0 0 889 676 Air required (cfm) 0 0 38 30 Calculations approved byACCA to meet all requirements of Manual J 8th Ed y*F wr19M1�oii- 2019-Apr.2913:17:40 EA Ri13 S N BEN ETTOl 2018 .n4) alc RSU08101 Page 2 ...5 HOMES- 1820 8 MODEL- 5313 SAN BENDETTO PL.rup Calc = MJB Front Door faces: SE wrightsoft' Right-J®Worksheet Job: 1820MODEL B Entire House Date: Apr2922019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772466-6799 Fax: 772-466.6796 Email: OUICKCALCS@AOL.COM 1 2 3 Room name Eglosed wall Room height BEDROOM 3 10.0 It 9.0 ft heaticool CLST 3 3.0 ft 9.0 ft heat/cool 4 5 Room dimensions Room area 13.0 x 10.0 ft 130.0 W 9.0 x 3.0 H 27.0 ft- Ty Construction number U-value (BtuIVWF) Or HTM (BtuNft2) Area (ft') or perimeter (8) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/PIS Heat Cool 6 11 I---G 93A-0ocs 2 glazing, clr Iow4- 2 A-4olg, clr low-e_ 2 glazing, clr low-e 2 glazing, clr low-e 11DO -_ _ _ 13A-flocs 0.143 0.650 _0.650 0.650 0.650 _ - 0.390 0.143 ne rye -ne se se _se_ sw . _._ 4.00 18.20 - 18.20 18.20 18.20 - 10.92 4.00 - 2.19 28.88 _ _26.88 21.07 22.59 _ . 10.34 2.19 ..- _...0-0 0 ._. 0 0 0 _ 0 90 0 _-- 0 0 0 . 0 -- - 75 -_ 0 0 0 0 0 0 - 300 _0 0 0 0 0 0 -- 164 _ .0 0 0 0 0 _ 0 27 _-.. _...0 0 0 0 0 _ 0 27 _ ._ 0 0 0 0 0 _ 0 106 -0 0 --- 0 0 0 - - -59 _. . Uf! .L--C W l--li L:9 2glazing, clr lower.. 13A-4ocs 2 glazing, clr low-e 11DO _ _ 16B730ad . .. .. _ 22A-top _ _0.650 0.143 0.650 _0.390 _ ,0.032 _ 1.358 sw. nw nw nw -_ - _. ._1&20 4.00 18.20 10.92 ` - __0.90 .. 38.02 21.07 2.19 26.88 10.34 - -1.60 _ 0.00 _.15 0 0 - _. 0 .. 130 _ _ 130 _ . .7 0 0 0 __.__130 _ . _. 10 .273 0 0 _ 0 . 116 - - , 380 .. _.316 0 0 _ 0 .. 208 _.. _ 0 -0 0 0 0 _ _.27 - 27 ... _0 0 0 -_ _ 0 ._ .. 27 _ 3 _ ...0 0 0 _ 0 ._. 24 _ _-. 114 __ _ _0 0 0 0 .__ 43 _ 0 C . F,. 6 c)AED excursion 101 -5 Emelope lossfgam 1070 789 246 97 12 a) Infiltration b) Room ventilation 173 0 49 0 52 0 15 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 600 0 Subtotal(lines 6to 13) 1244 1438 298 112 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 26% 45% 0 0 159 1402 368 0 0 72 1510 676 26% 45% 0 0 -298 0 0 0 0 -112 0 0 Total room load Air required(cfm) 1770 76 2186 97 0 0 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -1'}F wrrghtso^R- 2019-Apr-2913:17:40 I&-h RlghtSuite® Universal 201818.0.31 RSU08101 Page 3 ...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: BE wrightsoft' Right-JOWorksheet Job: 1820MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name AHU CLST DINING ROOM 2 Biposed wall 0 ft 11.0 If 3 Room height 9.0 It heat/cool 9.0 it heat/ccol 4 Room dimensions 4.0 x 3.0 ft 20.0 x 11.0 H 5 Room area 12.0 ft' 220.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft? °F) (Btuh1ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Coal 6 v - 13A:4ocs ._ _ ___._.0.143 fie -..:4.00 2A9 _ -. _0._ 0 __ 0 __ _ 0 _ __ .0 . -0 ___---0.._._. ------ -0 2 glazing, clrlowc 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 -0 2 glazing,clr lowe _. 0.040 ne_ _ 18.20.. 28.88_ 0 0_ 0 0 0 13AAccs 0.143 se 4.00 2.19 _ _._0 0 0 __0_.- 0 _ 0 _ 0 0 __ _0 0 0 11 2 glazing, clr low-e 0.650 se 18.20 21.07 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 se 18.20 22.59 0 0 0 0 0 0 0 0 11D0 , _ 0.390 se_ 10.34 0 0 0 0- 0 0 _ _ _ _ Y- _ ___. 13A-4ocs ,_ _ 0.143 sw __10.92 4.00 2.19 - _ _0 0 _ _ - --0 __. , -_0 0 - - - 0 99 - -151 _ . _ 2 glazin clr low-e . _ - - -0.650 sw. 18.20 - 21.07 -_ -0 _._ 0 __.. _0 _ -0 ... _ 30 _ .15 __ __ 546 _ ._ _ 632 vrl 13A-0ocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 F�-CD 2 glazing, clr low-s 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 11D0 ,- -_ _0.390 nw 10.92 10.34 0_ 0 0 0 0 0 0 0 C. ... 166a0ad. _ ._ 0.032 _-_ ._0.90 -1.60 _ 12 _ .__12 _ .. . _ . 11 _.. _ _ 19 _ ._ ._.. _ 220 _ - -_ _.. 197 _ . F - 22A-tp - . - .._ -___1.358 ,-, _38.02 _0.00 __12 _ _ 0 _0 _0 _. ..220 It. _ _418 .352 0 6 c)AED excursion _1 264 Emelope loss/galn 11 18 1438 1399 12 a) Infiltration 0 0 191 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6to 13) 11 18 1629 1453 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution Al -18 153 63 14 Subtotal 0 0 1782 1515 15 Duct loads 26% 45% 0 0 26% 45% 467 678 Total room load 0 0 2249 2194 Air required(cfm) 0 0 97 98 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -}r- wrtgFi�so�PC- 2019-Apr-2913:17:40 AA RighlSuite® Universal 201818.0.31 RSU08101 Page 4 ...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.mp Calc = MJ8 Front Door faces: SE wrightsoft, Right-M Worksheet Job: 1820 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCSo@AOL.COM 1 Room name BEDROOM 4 CLST 4 2 2posed wall 24.0 ft 8.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heaVcool 4 Room dimensions 1.0 x 161.0 It 3.0 x 7.0 ft 5 Room area 161.0 IF 21.0 fl2 Ty Construction U-value Or HTM Area (fl2) Load Area (ft2) Load number (13tuh/ft2-°F) (Btuhlf.) or perimeter (f) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 134.4o6s - ._ . 0343 re 4.00 219 0 - 0 - .. - .0 -'0 -_ 45 _. ._ 45 __ 18o .- _ 98 2 glazing, clr lower 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing, clr lower - _ 0.650 ne_ 26.BB 0 0 0 0 0 0 0 0 13A4ocs 0.143 se ..18.20 4.60 __ 2.19 _ _ 99 _ _ 69 ., _-.. _ 278 - 151 _ _ 27 _ - 27 _ _ 168 59 11 2 glazing, clr low-e 0.650 se 18.20 21.07 30 15 546 632 0 0 0 0 2 glazing, clr Im-e 0.650 se 18.20 22.59 0 0 0 0 0 0 0 0 11D0 __ - 0.390 se- 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw _ 4.00 2.19 - - 117 117 - -- 468- 256 - - - 0 - 0 - - - 0 - 0 2 glazing, clr low-e _ 0.650 sw 18.20 21.07 - 0 0 . 0 .0 0 _ _ .0 .0 .0 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 L13A-0acs �D 2 glazing, clr low-e 0.650 rw 18.20 26.88 0 0 0 0 0 0 0 0 _ 11DO _ 0.390 nw 10.92 10.34 0 0 0 0 0 0 0 0 C 16Mad- - _ _ 0.032 - _ _ 0.90 1.60 161 _ 161 - _ 144 _ 258 _ 21 21 19 34 F 22A-toh _ - _ 1.358 38.02 0.00 161 24 _ 913 _.. 0 _ 21 8 _ _ 304 - _ 0 6 c) AED excursion 105 -9 Emelope loss/gain 2348 1402 611 182 12 a) Infiltration 416 117 139 39 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2764 1519 750 221 Less Warm] load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 625 184 -750 -221 14 Subtotal 3389 1703 0 0 1151 Duct loads 1 269/6 45% 889 763 26% 45% 0 0 Totiral room load 4278 2466 0 0 Arequired (cfm) 184 110 0 0 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed - wrlghtsoft- 2019-Apt.2913:17:40 AM, RightSuiteO Universal 201818.0.31 RSU08101 Page 5 ...5 HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.rup Colo = Mill Front Door faces: SE wrightsoft• Right-J® Worksheet Job: 1820 MODEL 8 Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM i 2 3 4 5 Room name F)posed wall Room height Room dimensions Roam area FOYER 6.0 ft 9.0 It heat/cool 6.0 x 8.0 0 48.0 ft2 LAUNDRY 0 ft 9.0 It heatfcool 7.0 x 7.0 it 49.0 ft2 Ty Construction number U-value (Btuf✓ft' °F) Or HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load (Bluh) Area (ft2) or perimeter (0) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 11 Val �C 13A=flocs "_.. _ 2 grazing, clr lowe 2 glaring, clr Iowa - 13A-4ocs _ 2 glazing, clr Iowa 2 glazing, clr Iowa 11D0� _ 13A'13cs 2 glazing, ciclava _ 'a 2 glazing, clr lowe 11DO _., - _ . _ - 22A-tph-_ __ _ - -' 6.143 0.650 0.650 ..0.143 0.650 0.650 _ 0.390 0.143 _ .._ 0.650 0.143 0.650 _-0.390 1.358 1.358 fie ne re �as as as _se sw sw.. my my my , - = 4.00 18.20 1820 406 1820 18.20 _ 10.92 4.00 .. _18.20 4.00 18.20 - 10.92 0.00 38.02 ..2:19 26.88 26.88 .2.19.. 21.07 22.59 _ _10.34 2.19 ...21.07 2.19 26.88 10.34 _'1.00 0.00 . _. _ 0 -0 0 _.54 0 13 20 _... 0 _ . _ .0 0 0 0 _ _ _ _ 48 48 . _..__0 0 0 _ _. 21 0 5 20 ... 0 __ _ 0 0 0 _-_0 ._ _... _48 6 _ 0 0 0 82 0 244 - 219 0 .. .. 0 0 0 - __ 0 ... _ 43 228 ------0 0 0 45 0 303 208 _ _ . 0 ._ _._ 0 0 0 - 0 77 - 0 _ .. _0 0 0 .__. _ _0 0 0 _ 0 .. 0 _ _ _ 0 0 0 -0- _ 49 49 _ . __ 0 0 0 ._ __.0 0 0 0 -._0 _ .. .0 0 0 -_0 _ . __ 49 0 _ .. _0 0 0 _.__d 0 0 _ 0 .. 0 __ .0 0 0 0. _ 44 0 . -0 0 0 _ _ ..0 0 0 0 _ __ 0 . _ _ -0 0 0 0 - 0 _ _ _78 - , _ 0 _ W, VLZliA _ F16B30ad- F _,. 6 c)AED mursion 59 -32 F_melope loss/gain 817 691 44 46 12 a) Infiltration b) Room ventilation 104 0 29 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 700 Subtotal (lines 6to 13) 921 720 44 746 14 15 Less eldemal load Less transfer Redistribution Subtotal Duct loads 26% 450A 0 0 125 1046 274 0 0 37 757 339 26% 45% 0 0 0 44 12 0 0 0 746 334 Total room load Airrequired(cfm) 1320 57 1096 49 55 2 1081 48 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed A -r}f wrlgtiisoT2- 2019-Apr-29 13:17:40 RighlSuite® Unly rsal 201818.0.31 RSU08101 Page 6 ...S HOMES- 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJB Front Door faces: SE 1 wrightsoft Right-JO Worksheet Job: 1820MODELB Date: Apr 29, 2019 Entire House QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fa�c 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name KITCHEN FAMILYROOM 2 3 Exposed wall Room height 16.0 It 9.0 0 heatlowl 13.0 ft 9.0 ft heat/cml 4 5 Room dimensions Room area 1.0 x 2620 ft 262.0 fP 1.0 x 264.0 ft 264.0 ft' Ty Construction U-value Or HTM Area (f') Load Area (f8) Load number (Btuh/0'-°F) (Btulvft� or perimeter (f) (Btuh) or perimeter (ft) (Btuh) Heat Cool Grass N/P/S Heat Cool Gross N/PIS Heat Caol 6 11 1--G 13A7-4obs - 2 glazing, clr lowe 2 glazing,, clr I=7e - 13A-0ocs 2glazing, clr low-e 2 glazing, clr lcwe 11D0 ,_ ._ _ _ 13A-0ocs 2glaztrg,.clrlow-e._ .._ 13A-4ocs 0.143 0.650 ,0.650 0.650 O.fi50 0.650 _. __0.390 0.143 _-.0.650 0.143 re ne na as se as _ se. sw sw. nw .--.4.00 18.20 .1820 1820 420 1820 1092 4.00 ...18.20 4.00 `- 2.19 26.88 26.88 1.07 21.07 2259 _. 10.34 2.19 _... 21.07. 2.19 _. --144 0 _ 30 '. 0 0 0 _ _. _ 0 0 _ _ .0 0 iib 0 0 0 0 0 _.___ __0 0 . _ _. 0 0 ___--456 0 546 - __. .0 0 0 _ _0 0 _0 0 249 0 806 .,_ 0 0 0 _ _ .-0 - 0 _ _ 0 0 __ _. .0 0 0 _. .. _0, 0 0 _ _ __ 0 -'0 _- .__.0 117 .__ __ 0 0 0 _. .. e_ 0._._ 0 0 _ _ 0 0 - 69 ----..,0 0 __._0 0 0 0 _ ._ 0. 0 277 _ �.0 0 0 _._ _ .0 0 0 __. ._ 0 0 - -151 vf/ �(GD Lt. IN 2 glazing, clr lowe 11D0 - - _ _ 168-36ad 0.650 0.390 0.032 _ rnv nw - 18.20 10.92 .. _ 0.90 26.88 10.34 ... _1.60 0 _ 0 _ 262 0 0 ..... 262 0 _ _ - 0 235 0 _ _ 0 419 30 18 . 264 0 -18 546 _ 795 806 _ _ 185 422 _ C F-_ 22A tph 1.358 _ r 38.02 y0.00 _ - _ 262 _ ._ 1_6 _ _ _. 608 .._ - 0 _ ._ 264 __264 13 _ ...237. . _. 494, - _ _. ._ 0 6 c)AED excursion -130 156 Envelope loss/gain 1846 1345 1749 1721 12 a) Infiltration 278 78 226 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1600 1200 Subtotal (lines 6to 13) 2123 3023 1974 2984 Less e)demal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 2123 0 0 3023 0 13 19W 0 23 3007 15 Duct loads 26% 45% W7 1354 26% 45% 522 1347 Total room load 2680 4377 2509 4354 Air required (cfm) 115 195 108 194 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. =Lle lsan- 2019-Apr-29 13:17:40 .4•C�'A Ri13 S N BE Universal 2018 .n4) alc RMJB F 7 Page 7 ...6 HOMES- 1820 B MODEL- 5313 6AN BENDETTO PL.rup� Calc = MJ8 Front Door (aces: 8E wrightsofr Right-M) Worksheet Job: 1820 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1VRwm HALL O BATH 2ll 0 It 11.9 ft 3t 9.0 ft heat/cocl 9.0 ft heaUcool 4nsions 4.0 x 8.0 ft 1.0 x 130.5 ft 5 32.0 W 130.5 fN Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft' °F) (Btuhlf .) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool .0343 ne 4.00 .. _219 _ ---0 _. _ --0 0 . _0 _.-108 -LL.. _-102 "` __.�8 ._. _ 223 IL-GG 2 glazing, clr Iowa 0.650 ne 18.20 26.88 0 0 0 0 6 0 109 161 • 2 glazng,.clrlow-e .._ 0_650 ne: 1820 26.88 _.._ 0 0 0 0 0 0 0 ___. - 13A-0acs 0.143 se 400 2.19 0 �. _ 0 _ _0. U _ __ _._0 . ___0 . 0 .0 .. .0 11 2 glazing, clr Iowa 0.650 se 18.20 21.07 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.650 se 18.20 22.59 0 0 0 0 0 0 0 0 _ _ 11D0 , . _ _ __ _ 0.390 se_ �sw 10.92 10.34 0 0 0 0 0 Wi 93A-0ocs _ 0343 ___4.00 � _. 2.19 -_� _.0 _..� 0 _ ._. 0 - .. _ 0 _.._. __0 .-0 0 - _.0 _ 0 . _---G 2 glazing, clr Iowa_ __ 0.650-sw. -18.20 __21.07 ._. _.. 0_.__......._0 -_.0... .. _0 ._.. _.0 .. ._..:0 0 13A-flocs 0.143 nw 4.00 2-19 0 0 0 0 0 0 _ .___0 0 _ 0 2 glazing, clr Iowa 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 11D0 _ _ _ 0.390 nw- 10.92 10.34 0 0 0 0 0 0 0 0 _ 'C _ 16B30ad, -. ---, _ _0.032 r _ 0.90 .-- 1.60 _ _ _.32 . - �32 _- _ 29, ,51 _ _117 _ F _ 22A-tph ._ . 1.358 - 38.02 0.00 ---32 _0 0 _0 ----131 131 _._ _131 _ _ . 12 _- ....453 - ,200 ._ _ _..0 6 c)AED excursion -2 -37 Envelope loss/gain 29 49 1088 556 12 a) Infiltration 0 0 208 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Apqianceslother 0 250 Subtotal (lines 6to 13) 29 49 1296 865 Less exdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -29 -49 0 0 14 Subtotal 0 0 1296 865 15 Duct loads 26% 45-A 0 0 26% 45% 340 387 Total room load 0 0 1836 1252 Air required (cfm) 0 0 70 56 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -}/- wrigh,�oft- 2019-Apr.2913:17:40 149& RightSulte® Universal 201818.0.31 RSU08101 Page 8 ...S HOMES. 1820 B MODEL- 5313 SAN BENDETTO PL.mp Cato = MJ8 Front Door faces: SE wrightsoft' Right-J®Worksheet Job: 1820 MODEL Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E:yxrsad wall Room height Room dimensions Room area O WIC 0 8 9.0 ft heaVcocl 1.0 x 37.5 it 37.5 ft2 OWNERSBEDROOM 40.0 ft 9.0 0 heat/cool 14.0 x 16.0 It 224.0 ft' Ty Construction number U-value stultlf W) Or HTM (Btuh/ftg Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (8tuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Y�1' 1-G 13A-06cs - 2 glazing, clr Iowa 2glazirg; cfrlow-e _ 13A-4ocs 2 glazing, clr Iowa 2 glazing, clr Iowa 11D0 _ 13A46cs7 2glazing, cir Iowa . _ 13A-0acs 2 glazing, clr Iowa 12 _ IS _ 22A_toh _ - _ 0143 0.650 0.650 0.149 0.650 0.650 _0.390 0.143 .__ 0.650 0.143 0.650 _ 0.390 _ _1.358 _ _ _ 1.358 ne ne ne se se se se sw _sw. nw nw nw _. - . - . -74.00 1020 18.20 4.06 18.20 18.20 -, 10.92 4.00 . .:18.20 4.00 18.20 10.92 _._0.90 38.02 -- 2.19 26.88 _ 26.88 2.19 21.07 22.59 -10.34 _ _2.19 _21.07 2,19 26.88 _ 10.34 _ 1.60 _ 0.00 _ ---0 0 0 0 0 0 _ _ _0 0 _ .: . 0 0 0 0 . ._ 38 _ -38 __ _ . 0 0 _ 0 0' 0 0 _ - -_0 � 0 _.. -. 0 0 0 0 _. _ 38 _ 0 ..._ _..-0 0 ___ 0 _0 0 0 _ -, - 0 0 _ 0 0 0 0 34 - _ _ 0 ._.. _ _ -0 -0 ___-- 0 0 0 0 0 --.- -0 . __ _0 0 0 0 _ -60 - _ _0 ......1m 0 _ _ _15 � 0 0 0 0 - OD . ..-0 126 15 0 _224 - 224 ... ..129 0 _ 0 0 0 0 0 � -�90 _ _ .0 111 0 0 _ __.224 _ 40 ._--- 517 0 -___27.3 0 0 0 _ _ _ 0 360 _. __ _0 444 273 _ 0 _ _. 201'.. 1521 .. _ 2B2 0 4.03 ___ 6 0 0 _ 0 � � 707 243 403 _ 0 _ 358 0 V7! {L-----GD _._.. _ C F _ 6 c)AED excursion -2 89 Ernelope losslgam 34 58 3589 1818 12 a) Infiltration b) Room ventilation 0 0 0 0 694 0 196 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13) 34 58 4283 2914 14 15 Less eldemal load Less transfer Redistribution Subtotal Duct loads 26% 45% 0 0 0 34 9 0 0 0 58 26 26% 46%1 0 0 0 4283 1124 0 0 0 2914 1305 Total room load Air required (cfm) 42 2 83 4 5407 232 4218 188 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -rw wr�gh�oR- 2019-Apr-2913:17:40 Ri13 S N BEN niversa12 .ru 18Calc RMJ8 F 1 Page 9 ...5 HOMES- 1820 B MODEL- 5313 SAN BENDErfO PL.rup Calc = MJe Front Door faces: SE wrightsoft Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM Project Information For. ADAMS HOMES 5313 SAN BENDETTO PLACE, FORT PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/10Dft 1167 cfm 180 Job: 1820 MODEL B Date: Apr29,2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 iN100ft 1167 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) CIg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 889 38 30 1.000 5.0 OX0 VIFx 15.7 115.0 SO BEDROOM 2 h 4356 187 98 1.000 7.0 OX0 VIFx 21.7 115.0 st1 BEDROOM 3 c 2186 76 97 1.000 7.0 OX0 VIFx 18.9 115.0 st1 BEDROOM 4 h 4278 184 110 1.000 7.0 OX0 VIFx 21.6 115.0 st3 DINING ROOM c 2194 97 98 1.000 7.0 OX0 VIFx 20.4 115.0 st3 FAMILY ROOM c 2177 54 97 1.000 7.0 OX0 VIFx 15.8 115.0 st1 FAMILY ROOM -A c 2177 54 97 1.000 7.0 OX0 VIFx 17.1 115.0 st1 FOYER h 1320 57 49 1.000 6.0 OX0 VIFx 19.9 115.0 st3 KITCHEN c 2189 56 98 1.000 7.0 OX0 VIFx 27.2 115.0 st2 KITCHEN -A c 2189 58 98 1.000 7.0 OX0 VIFx 25.2 115.0 st2 LAUNDRY c 1081 2 48 1.000 6.0 OX0 VIFx 23.6 115.0 st3 DBATH h 1636 70 56 1.000 6.0 OX0 VIFx 23.0 115.0 st2 OWIC c 83 2 4 1.000 4.0 OX0 VIFx 43.8 135.0 st4 OWNERS BEDROOM h 2703 116 94 1.000 7.0 OX0 VIFx 40.3 135.0 st4 OWNERS BEDROOM -A h 2703 116 94 1.000 7.0 OX0 VIFx 44.7 135.0 1 SW Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 PeakAVF 234 192 1.000 670 8.0 0 x 0 VinIFIX st2 st2 PeakAVF 419 443 1.000 671 11.0 0 x 0 VinlFlx st3 PeakAVF 339 305 1.000 768 9.0 0 x 0 VinlFlx SH PeakAVF 409 419 1.000 636 11.0 0 x 0 VinlFlx wrightsoft' tots-Apr-2s 13: t7:at CA •�»•� •- -.•-+. RightSuiteS, Universal 201818.0.31 RSUD8101 Page 1 ...S HOMES. 1820 B MODEL- 5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: BE Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 ox0 1167 1167 0 0 0 0 Ox 0 VIFx wrightsoft' 2019-Apr-2913:17:41 •�+ •�—+�-+-, Right -Suite® Universal 201818.0.31 RSU08101 ,Page 2 '�` ...S HOMES- 1820 B MODEL-5313 SAN BENDETTO PL.rup Calc = MJ8 Front Door faces: SE