HomeMy WebLinkAboutSUBMITTED DOCUMENTS'_„ DIVISION OF ENGINEERING MEMORANDUM 99-116 SCANNED To: Martha Schurmann, Building Division BY From: David Hays, Engineeri St. Lucie County Date: April 6, 1999 Subject: EKE Midway Mobile As -Built Acceptance Building Permit=_#.98100079= _S Engineering has reviewed the paving and drainage as-builts for this project and are excepting them for completion at this time. A copy of the Engineer's certification is attached for your records. If I can be of further assistance to you in this or any other matter, please let me know. cc: Donald West, County Engineer Charles Cangianelli, Code Compliance Manager File FRISCIA ENGINEERING 681 S.W. Whitmore Dr. a Port St. Lucie, Florida 34984 a (561) 340-4990 a Fax (561) 340-7996 email: joefriscia@hinet.com March 31, 1999 David Hays St. Lucie County Engineering 2300 Virginia Ave. Fort Pierce, FL 34982-5652 Re: EKE Midway Mobil MAR 2 9 rm� ( J NEC Selvitz & Midway Roads E ,-<_,".;_..--,,J I As -built Certification Building Permit No. 98100079 Dear Mr. Hays: This letter is to certify that construction of the subject project has been completed in substantial conformance with the approved plans, except as noted: 1. The car wash and the traffic separator on the north side of the car wash was not constructed. 2. The parking stalls and vacuum islands have been re -arranged on the south side. 3. The 6" step at the pavement and sidewalk interface at the east side of the store has been partially eliminated to avoid a tripping hazard. An as -built record drawing is attached for your records. Material test reports are on file at our office. If you have any questions, please call. Sincerely, J eph T. Friscia, P.E. Attachments: 1. Paving & Drainage Plan (2 prints, 1 vellum) cc: R. Priest File 98186sle.doc Site Plans a Water & Sewer Design Drainage Plans a Permitting ST. LUCIE COUNTY COMMUNITY DEVELOPMENT DEPARTMENT BUILDING & ZONING DIVISION 2300 VIRGINIA AVENUE FT. PIERCE, FL 34982 (561)462-1553 ST. LUCIE COUNTY ZONING COMPLIANCE Zoning Cert #: 44981 *001 Issue Date: 04/09/99 This is to certify that the following described property is properly zoned for: ERE MARKET: CONVENIENCE STORE & SANDWICH SHOP W/ �.'. ':-GAS AS AN ACCESSORY(5411)- NOTE*:60 DAY CONDITIONAL ZONING COMPLIANCE SUBJECT TO COMPLIANCE WITH CONDITIONS OF TEMPORARY CO Business Address: 4090 MIDWAY W RD Applicant's Name: PETER ECONOMYS Property Tax ID #: 3403-502-0154-000/1 Zoning: CH Subdivision: WHITE CITY S/D Lot: Block: STR: 05-36-40 Map#: 3405N signature Section 3.01.00 Zoning District Use Regulations G. RE-2 RESIDENTIAL. ESTATE - 2 1. Purpose ------`"= The purpose:of this-"distii&ls'to povideland protect an environment suitable for single-family - dwellings of a maximum gross density of two (2) dwelling -units per acre., together With such other . uses as may be necessary for and compatible with low density residential surroundings.<She number in "Q"'following eacfi-identified use correspond§ to the SIC code reference described in Section 3.01.02(Bf ' The number 999 applies to muse not defined under the SIC`code but may be further defined in Section.2.00.00 of this code. 2. Permitted Uses a. Family day care homes. c m) ' b. Family restdehtial homes provided thatsuch homes'shall not be located within a radius of one thousand (1000) —'-"t of ahotheV existing such family residential home and provided that the sponsoring agericy`or Department of Health and Rehabilitative Services (HRS) notifies the Board of County Commissioners at the time of home occupancy that the home is licensed by HRS. (sea) y C. Single-family detached dwellings. (ees) — 3. Lot Size Requirements Lot size requirements shall be in accordance`with Section 7.04.00: :. C_. 4. Dimensional Regulations Dimensional requirements shall be in accordance with Section 7.04.00. 5. Off-street Parking Requirements Off-street parking requirements shall be in accordance with Section 7.06.00. 6. Conditional Uses a. Bed & Breakfast Residences - Subject to the requirements of Section 7.10.20; (ees) b. Family residential homes located within a radius of one thousand (1,000) feet of another such family residential home. (m) C. Telecommunication towers - subject to the standards of Section 7.10.23 (ties) 7. Accessory Uses Accessory uses are subject to the requirements of Section 8.00.00, and including the following: a. Guest house subject to the requirements of Section 7.10.04. teegl b. Horses, subject to the requirements of Section 7.10.03. (ees) Adopted August 1. 1990 104 Revised Through10101197 RATE:PERMIT NO: /� ID �4` C�� ,.. FEErY ��� 00 RECEIPT NO: ep Ttl nm -- 0"ICa "SX OWLY.- f j ST. LUCIE COUN'1`X 1 D 'VEGETATION REMOVAL PERMXT APPLICATION eat of Comaraal please complete the requested information and submit all hems to the St. Luce County Department � � Development, 2300 Virgtnla Avenue, Ft. Pleree, FL, 349U U it is determined that Countypro vegedtk be removed, a fee of $50.00 (residential) or $100.00 (eommerdai) will be required. For additional detalls-oa the information necessary for submission of a vegetation removal perm(t application, please refer to Section LLOSA69 St. Ludo County land Development Code For additional information, please contact the St. Lack County Department of Community Development at 5611462-1553. AtLVFX;ETA71ON RFMOVALAPFUCATIONS MOST BECObOLLrMANDFII=wR?;TMDEPARTNE NrBEFORM 4aG PM FACa BUSTIGMS OAV. ..•NN•HNKNN.••.•N..•N S1BMi1TAL)K9QU RW02M FOR VEGETA'1xON REMOVAL PERMITS 1) One (1) original copy of the completed vegetation removal permit application; ands 2) Two (2) copies of a site vegetation survey. A- For individual single-family or duplex development lots, the site vegetation survey may be schematic provided that the appiicatioa is accompanied by sufficient photographs that accurately and completely depict the areas for vegetation removal or"protection. 13L For any residential development activity which mquhes tho•submittai of a site plan approval. or any non-residential development activity, the site vegetation'survey must accurately depict the location of all protected vegetation, as defined by the St. Ludo County Land Development Oode, and shall include a sufficient number of ground photographs that accurately and completely depict the areas for vegetation removal. Aerial photogmpb may bo used in conjunction with the vegetation survey. All site vegetation surveys mast clearly depict the following information:. . L. Location and eft of all County defined ptWmded vegetation on the propatty proposed for dearnl& All protected vegetatioa abaci be identified by Us common or scientific frames; Z. Identify ttII protected atq efatian proposed far removal (rvgoleed fmioimtuht dumekrc of ft probated trees air shown in the tablo below). PmWo the number of trees, species cad fret diameters in a tabular data boa on the site vrgiefation survey. 3. Lomtioa of an e:dtit and prvpaaed shndrrres (c.& houses, septic tanks, dri+ ways); NOTE Site deecloamcnt oians mug have the wzmf papimd toThe muse sale or Ina mumer which Wustoks the reLftoashtps Wawa EMAS or retetadon and proposed sffe lmpN+coaenb. — o ___ o.�o ,. a.•ocrn • r•caa�.an. r. c_ .�oa o•.o •vvo r. oo PERbvr woRMATION DESCRnrnON OF VEGETATION REMOVAL ACTIVTI•Y (LAND CLEARING A.NDIOR TREE REMOVAL): __Land --clearing and tree removal for new construction. NUMBER .AND TYPES OF TREES TO BE REMOVED (5 OAKS, 10 PINES, ETC): 4 pines 3 oaks PURPOSE OF VEGETATION REMO VAL (DESCRIPTION OF PROPOSED DEVELOPMENT ACTIV M: To construct convenience store/filling station DATE WORK IS EXPECTED TO BEGIN: DATE WORK IS EXPECTED TO BE COMPLETE: CONTRACTORS NAME: 8/11/98 R.K. Davis Construction ADDRESS: P.O. Box 186 9/1/98 PHONE(DAXT�)__ 561-461-8335 Ft. Pierce CITY: STATE: FL ZIP: 34954 FL REG/CERT. # ST. LUCIE CO. CERT. # PLEASE HAVE THE FOLLOWING ACKNOWLEDGEMENTS NOTARIZED: '' I CERTIFY THAT. (CHECK ONE) - A. ( ) --I-AM THE -OWNER OF RECORD OF THE ABOVE DESCRIBED PROPERTY- B. (KX) I AM NOT THE OWNER OF REOORD OF THE ABOVE DESCRIBED PROPERTY, HOWEVER, I HAVE AUTHORITY TO ACT AS AOF.NP FOR THE OWNER OF RECORD. (PLEASE PROVIDE DOCUMENTATION). I CHRTIFYTHATALL INFORMATION SUBMITT M WrM THIS APPLICAMON IS TRUE AND COMPLETE TO THE BEST OF MY KNOWLEDGE, SIONATUR&- / ` r-• .. DATE 4 i 1 OWN) VA( ENT SIGN Peter Economys, PScesident, Ekonomy Enterprises, Inc. STATE OF EWRIDA, COUNTY OF Sr. LU'CIE The foregoing Instrument was ac$mowiadged before me this .7.7wd day of a" 67 19 9fr , by PETCR EGoA/O "'y f .who Daliy Im to me or has produced as identTBcation. S ture of No Type or Mat Name of MhMq 7f.1 NGSb5.�u MYCM0N721tel o;-• AINJAW WUM ID-lk-P ARY ) ...............0"t FOR OFFICE VSB ONLY APPROVED ( ) DMAPPROVW f CONDMONS: 424er ry 2 - IS7 / Gs en,? lzs P trh ENVIRONMENTAL PL ANNER: DATE: SITE INSPECTION: DATE: FINAL INSPECTION: DATE: Y PROJECT WORMATION PROJSGT ADDRESS: Northeast corner Selvitz & MIdway Roads PRO= NAME EKE MIDWAY MOBIL Summon White City S/D LOT: 90 BM - SECT: 5 TWNSBP: 36S ZONING: C& i ARID I FSF?- PROPERTY TAX ID #: PARCEL SIZE (ACRES OR SQ. FT.): RNG: 40E MAP#: U07/71 3.84 Acres LEGAL DESCRIPTION (ATTACHED EXTRA SHEET IF NECESSARY): See attached Exhibit "A" OWNER NAME: Marvin & Frances C. Naftal and Martin Naftal ADDRESS: P.O. Box 1288 CITY: Palm City STATE: FL - ZW: HOME #: (�a CHECK APPROPRIATE BOX: SINGLE-FAMILY/DUPLEX () NON-RESIDENTIAL ( ) MULTI FAMILY () PUBLIC ( ) MAST ST. LUCIE COUNTY PROPERTY APPRAISER REQUEST ( ) * PARCEL MASTER SCREEN I.D•.(3403-502-0154-000/1 ) PAGE (01) OF 1 NAFTAL, MARVIN & FRANCES G NAFTAL, MARTIN NA,FTAL, JOSEPH (EST) NAFTAL, ANNA (EST) ET AL PO BOX 1288 PALM CITY,FL 34991-6288 ------ LEGAL/PROPERTY DESC ----- WHITE CITY S/D 05 36 40 S 1/2 OF LOT 90-LESS W 50 FT FOR SELVITZ RD R/W & LESS TO MIDWAY RD R/W AS IN OR 44 P 445- (3.85 AC) (MAP 34/05N) (OR 524-793: 933-2178) OLD TRAN-PRO FUNC ( ) 10/14/98 11:52 TAX YEAR(C) 1998 VOID YIN(N) D.O.R. CODE 1000 DATE SOLD CLASS. USE CODE SALE AMT SECTION O5 O.R. BOOK TOWNSHIP 36S O.R. PAGE RANGE 40E MAP ID SPECIAL DIST 0154 TAX AUTH. SUBDIVISION 3403502 NOTES LENDING INST. * LAND(MKT) LOAN * IMPR VACANT/IMPRV * CLASS USE V VAC SALE * ASSESSED QUAL/CODE * AMEND 10 01 DISQ SAL * EXEMPTION 07/31/96 V 100 1034 0848 34/05N 02COUNTY YES 61900 61900 PARENT ID NO. * TAXABLE = 61900 ----------------------------- EXEMPTIONS ----------------------------------------- NOT:H: W: C: M: EXEMPT STATUS *** THIS INFO IS BELIEVED CORRECT BUT IS SUBJECT TO CHANGE AND NOT WARRANTED *** 1-LI 2-NA 3-NA 4-NA 2:10 PAGE FMT ON KBD v2.64 NCR 301 r KASER I MGMEERWG AND "I' S MG, INC. 3506 INDUSTRIAL 33id snuier FORT PIERCE FLORIDA 34946 i167 FORT PIERCE(561) 461.75M SMART (561)283.7711 FIE. PERRCE 1-S00-233.9011 14 Report Of DENSITY OF SOII, IN PLACE ASTM D2922 r CLIENT: Ekonomy Enterprises DATE: 11/16/98 1 CONTRACTOR: Pave Tech „ 1 SITE: Mobil Station - Midway Road & Selvitz Road Perm' �t=ee# 9.8T_ OD0,79"r Foundation Fill DENSITY TEST NO. DATE TESTED LOCATION ELEVATION MID DEN RELAI-IONSI01P IN PLACE 'DRY DENSITY PERCENT COMPACTION TEST NO. MAR. DRYRT. B 102 11/16/98 S.E. Comer 0 - 1' 13101 116.3 114.4 98A 103 S.E. Comer 1- T 115.3. 99.1 104 S.E. Comer 2 - 3' 116.0 99.7 105 Center 0 - 1' 114.3 98.3 106 Center 1- T 115.1 99.0 107 N.W. Comer 0- 1' 115.3 99.1 108 N.W. Comer 1 - 2' 115.7 99.5 ALL ELEVATIONS BELOW SLAB GRADE Copie's: Client -I ' Contractor - 1 OD C 1998 COMMU EVELOPMENT ST. LUCIE COUNTY FL Respectfully submitted, FRASER ENGINEERING AND TESTING, INC. Alexander H. Fraser", P.E. Fla. Reg: No. 16778 GEOTECHNICAL ENGINEERING FOUNDATION INVESTIGATIONS CONCRETE. SOIL. AND ASPHALT TESTING e FRASER AGINEERING AND TjaTMG, INC. 3501 INDUSTRIAL 33RD STREET FORT PIERCE, FLORIDA 34M VERO BEACH (56123676167 FORT PIERCE (561) 461.7598 STUAFiT (581) 789-7711 Fr PIERCE t-nnr-m 9011 Report Of MOISTURE DENSITY ASTM 1557-78 CLIENT: Ekonomy Enterprises i CONTRACTOR: Pave Tech SITE: Mobil Station - Midway Road & Selvitz Road Foundation Fill P.C.F. Dry WeigE e le 12 14 Moisture % or Dry weight DATE: 11/16/98 Test No. Test Method Sample Location Op' um um Moisture % Mac Dry Density- P.C.F. Soil Description B101 B Composite IO.o 116.3 Brown, slightly silty, slightly clayey, fine sand. Respectfully submitted, FRASER ENGINEERING AND TESTING, INC. 94J. " Alexander H. Fraser, P.E., Florida Reg. No.' 16178 GEOTECHNICAL ENGINEERING FOUNDATION INVESTIGATIONS CONC°E'E. SOIL AND ASPHALT TESTING REQUEST FOR 30 DAY TEMPORARY POWER RELEASE DATE: /V%AsLcH /6, /999 - PERMIT NUMBER: PROPERTY ADDRESS: St. Lucie County Comm. Devel. Dept. Code Compliance Division 2300 Virginia Avenue Fort Pierce, FL 34982-5652 Ph. (561) 462- 2165 Fax (561) 462-1735 �Ofo GY- 1t11Dq//!Y AVAC .. THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FORA PERIOD NOTTO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARA- TION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THIS REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release is requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. All conditions and requirements listed in the attached document entitled "Requirements for 30 Day Power for Testing" have been fulfilled and the premises is ready for compliance inspection. We hereby release and agree to hold harmless, St. Lucie County, and their employees from all liabilities and claims of any type or nature which may arise now or in the future out of this transaction, including any damages which may be incurred due to the disconnection of electrical power in the event of violation of this agreement. v -1,� I J MAR 17 1999 COMMUNITY DEd EL FL I . i trir r.OU Total Roofing Systems Inc. OR 2 9 1999 ' 7205 Roofing • A/C Mechanical • Custom Sheet Metal Fabrication State Cert. CCC056811 CMC042537 2, 1999 Building Department St Lucie County Fax: 561-462-1148 Reference: Convenience Store and Self Serve Gas Station ) Midway Road Fort Pierce, FL G C Pe:AL/Y i7T Z& 99 - /oo 99 — 2 k: D.4IPS The Rigid Insulation for the above project was installed as follows: 1) 3" Polyisocynurate (R=21) was installed over plywood deck. Secured with screws and 3" galvalume insulation plates and according to FM I-90 fastening pattern (enclosed). 2) 1/2" Perlite 4 x 4 sheets (R=1.32) fully adhered in hot asphalt. Installed over ISO. The Johns Manville Four Ply Built -Up Roof Specification 4GIS (enclosed) was then installed. The insulation and built-up roof was installed according to manufacturers recommendations. Respectfully, TOT L ROOFING STEMS, INC. Ha7y Tassell Project Estimator (561) 340-5539 2100 Conant Avenue Port St. Lucie, Florida 34953 Fax (561) 340-2779 Ij P.O. BOX 3030 FT. PIERCE FL. 34948-3030 2400 RHODE ISLAND AVE. FT. PIERCE FL. 34950 ST. LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PLAN REVIEW TELEPHONE FAX NO. (561)-462-2312 (561)-462-2323 JURISDICTION: St. Lucie County F.P.B. # 1074 OCCUPANCY: EKE Midway Mobile BUILDING DEPT. NO: 98100079 ADDRESS: 4090 Midway Rd. " NUMBER OF STORIES: One CONTRACTOR: Richard K. Davis PHONE NO: 461-8335 ARCHITECTIENGINEER: Richard Wensing PHONE NO: (561)-684-1990 BUILDING OWNER: Ekonomy Enterprises, Inc. > - REVIEW DATE: 10-22-98 OCCUPANCY TYPE: Mercantile "C" AUTOMATIC SP'KLRS: No GROSS SO FT: 3,600 sq ft. = "= NET SO FT: Sales-1,745 sq ft. OCCUPANT LOAD: 58 persons BASED ON: 30 sq ft PIP net sales. CONSTRUCTION TYPE:( NFPA-220) Type: 111-(200) SBCCI: Type: V- Unprotected New Construction: X Automatic Sprinkler. Contractor. Tenant Improvement: Fire Alarm System Contractor. Shell Only: Fixed Fire Suppression: Contractor. Addition: Hood & Duct System: Contractor. l , Renovation: Fuel Storage: Contractor. " 1. All revisions must be in compliance before the final inspection, or so noted. 2. The Fire Marshal requires 24 hr. notice on all inspections. 3. The Building Departments schedule all final inspections by the Fire Marshal. 4. A copy of the required revisions has been mailect.to the Architect: _ Contractor: _ Yes: _ No: X_ Required Revisions: This permit review is for the construction of the mercantile occupancy only. A separate permit is required for the installation of the underground storage tanks, piping, and the dispensers. 1. If the exterior doors marked D-1 & D-2 are sliding doors they shall meet the requirements for a power operated doors as indicated in NFPA 101-5-2.1.9. or a side hinged door shall be provided. 2. Provide a 3A-40 BC rated fire extinguisher. 3. Provide a kill switch for both dispenser islands. Mount in the vicinity of the check out window. 4. The A/C automatic fan shut down requires a.listed duct type smoke detector mounted in the supply air only of each unit. Because a fire alarm system is not required a remote test station with a sounder shall be provided. Mount in'a normally occupied area. Y: Reviewed By Date: October 22, 1998 John K. H yde Whole.Building Performance Method for Commercial Buildings ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-94 Version 2.1A PROJECT NAME_EKONOMY-MIDWAY ADDRESS: _MIDWAY ROAD FT. PIERCE OWNER: _EKONOMY ENTERPRISES AGENT: Form 40OA-94 PERMITTING OFFICE: _Fort Pierce CLIMATE ZONE: 6 PERMIT NO: _PENDING JURISDICTION NO: 661100 BUILDING TYPE: _Mercantile (Retail) CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _3425 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 8 NUMBER OF ZONES: 1 COMPLIANCE CALCULATION: METHOD A DESIGN CRITERIA RESULT --------------- A. WHOLE BUILDING 72.91 100.00 PASSES $RESCRIPTIVE REQUIREMENTS: LIGHTING EXTERIOR LIGHTING 1225.00 10260.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. EER 9.00 8.90 PASSES IPLV 9.40 8.30 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION LEVEL 1. Conditioned Space 4.20 0.00 N/A WATER HEATING EQUIPMENT 1. EF 0.90 0.89 PASSES PIPING INSULATION REQUIREMENTS : 1. Non -Circulating 1.00 1.00 PASSES ---------------------------------------------------------------------------- COMPLIANCE ION: I hereby cethe plans and Review of the plans and specifica- specificatiby this calcu- tions covered by this calculation lation are ce with the 4cv indicates compliance with the Florida Eneency Code. Florida Energy Efficiency Code. PREPARED BY Before construction is completed, DATE: this building will be inspected for compliance in accordance with I hereby certi a his building is Section 553.908, Florida Statutes. in compliance wi the Florida Energy BUILDING OFFICIAL: -Efficiency Code. DATE: OWNER/AGENT: DATE: I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. _ DESIGNER /STATE ARCHITECT : MECHANICAL: PLUMBING / i ELECTRICAL: LIGHTING (*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. a BUILDING INFORMATION COMPLIANCE CHECK 401.------GLAZING--ZONE 1------------------------------------------------ v- Elevation 'Type U SC VLT Shading Area(Sgft) -------------- ---------- ------------------------ ---- ---- ---- North Commercial 1.1 .67 .55 Continuous Ove 23 East Commercial 1.1 .67 .55 Continuous Ove 96 East Commercial 1.1 .67 .55 Continuous Ove 105 South Commercial 1.1 .67 .55 Continuous Ove 294 South Commercial 1.1 .67 .55 Continuous Ove III - South Commercial 1.1 .67 .55 Continuous Ove 146 Total Glass Area in Zone 1 = 774 Total Glass Area = 774 402------- WALLS --ZONE 1------------------------------------------------ --- Elevation Type U Added R Gross(Sgft) ----- ------- ----------- ----------------------------------------- North L & Hvywt. Concrete Block + 8" H 0.172 0 1170 East L & Hvywt. Concrete Block + 81, H 0.172 0 540 South L & Hvywt. Concrete Block + 811 H 0.172 0 1260 West L & Hvywt. Concrete Block + 811 H 0.172 0 540 Total Wall Area in Zone 1 = 3510 Total Gross Wall Area = 3510 403.------DOORS--ZONE 1------------------------------------------------ --- Elevation Type U Area(Sgft) ----- ---------- •--------------------------------------------------- West 1-3/4 Steel Door -Polyurethane core (24 0.20 28 Total Door Area in Zone 1 = 28 Total Door Area = 28 404------- ROOFS --ZONE 1------------------------------------------------ --- Type Color U Added R Area(Sgft) ------ ---------------------- ------------------------------------ 1" Wood with 1" Insulation Medium 0.170 6 3600 Total Roof Area in Zone 1 = 3600 Total Roof Area = 3600 405.------FLOORS-ZONE 1------------------------------------------------ --- Type R Area(Sgft) ----------------- ------------------------------------------------ Slab on Grade/Uninsulated 0 3600 Total Floor Area in Zone 1 = 3600 Total Floor Area = 3600 406------- INFILTRATION -------------------------------------------------- --- CHECK Infiltration Criteria in 406.1.ABC.1 have been met. I 407------- COOLING SYSTEMS----------------------------------------------- --- Type No Efficiency IPLV Tons ---------------------------- ------------- ------------------- 1. Air Cooled ( >= 65,000 Btu/h 1 9 9.4 7.50 408------- HEATING SYSTEMS----------------------------------------------- --- Type No Efficiency BTU/hr -------------------------------- ------------- -------------- 1. Electric Resistance 1 1.0 32000 409.------VENTILATION --------------------------------------------------- --- CHECK Ventilation Criteria in 409.1.ABC.1 have been met. I 410------ AIR DISTRIBUTION SYSTEM---------------------------------------- --- AHU Type Duct Location R-value A, 1. Split / PTAC Air Conditioner Conditioned Space 4.2 411.-----PUMPS AND PIPING -ZONE I --------------------------------------- Type R-value/in ---------- Diameter -------- Thickness ------------------------ 1. Non -Circulating 4 •75 1 412.-----WATER HEATING SYSTEMS -ZONE 1 ---------------------------------- Type Efficiency StandbyLoss -------------------- InputRate Gallons -------- ---------------------------------- 1. Electric(<=12 KW) .9 0 3500 30 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------------- ICHECK Metering criteria in 413.1.ABC.1 have been met. Transformer criteria in 413.1.ABC.2 have been met. 414.-----MOTORS --------------------------------------------------- ----- Motor efficiencies in 414.1.ABC.1 have been met. .415.-----LIGHTING SYSTEMS -ZONE 1 --------------------------------------- Sgace Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- •Type C(Mix 1 On/Off 6 On/Off 2 8393 3335 Toilet and 2 No visual task 1 None 0 240 90 Total Watts for Zone 1 = 8633 Total Area for Zone 1 = 3425 Total Watts = 8633 Total Area = 3425 CHECK Lighting criteria in 415.1.ABC have been met. ------------------------------------------------------------------ 16. HVAC load sizing has been performed. (407.1.ABC.1) ------------------------------------------------------------------ 17. Duct sizing and design have been performed. (410.1.ABC.1.2) ------------------------------------------------------------------ 18. Testing and balancing will be performed. (410.1.ABC.4) ------------------------------------------------------------------ 19. Operation/maintenance manual will be provided to owner.(102.1) ------------------------------------------------------------------