Loading...
HomeMy WebLinkAboutPOOL PLANS6 X 6 WATERLINE TILE 2 X 6 STEP TIL,E___�__� OVER POUR HAND HOLDS_ GEM FINISH BABY BARRIER i DECKING ll AQUA RITES SALT C111LORINAT01 I I I WOODEN FENCE SURIRC►UNDIh' lG YARD 46 ft. 10 in. EFFECTIVE JANUARY i FLA. STATUTE CHAPTER 424 REQUIRES ALL SYVII+AM'NG POOLS TO COVERS, SELF -CLOSING DOC" OR ALAIiAit SYSTrall's. LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 POOL: 393 SI FT. X 81 LF. DECK: 889 SC FT. 00 B�ol�r�dW1�D Illme YFO � Y, J . MUSTEE'�'ND 6ffM No eItispva II C pd wail oar °oil q SE M.40E —w----------------------------------------- --———— — — — --- 1 ® 6 MIL. VISQUEEN s� I I I I I WATER DEPTH AT BOTTOM I I. I STEP WILL NOT EXCEED 48" I I, I PER FBC 6.2.2.2 5 fr.. 4ln 1 24 ft. 6; 3'DEEP I 74_ft. 0 in. _ I i TILED II STEP L LIGFI( EDGE � I a O I SKIMME AC ---------- Al �Nlq la' I F i' ------------------------------ DEEP TILED EDGE Ar� ® SU DECK I I I' KOOL DECK _____________-- EXISTING PATIO SAFETY BARRIER IS NOT CLOSER THAN 20" FROM POOL SAFETY BARRIER PER FBC 424..17.3 AND ANSI/NSPI-6.1995 — i77-----------------------------------------I THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. illy I BY St. LucieCour THE°� HillEN EVER R;VIEWED I � ; Imf a�ICE WITH THE FLORIDA e POOL SPECIFICATIONS I MAXIMUM WIDTH 21 MAXIMUM LENGTH 24`5" MINIMUM DEPTH 3 Mawmiu88 efRRTY 5 J 300 WATT NA M UT THERAPY WITH I ELECTRICAL HOOKUP ENERGIZED 1 1 MOASICS NO 1 OWNERS HEREBY ASSUME AND AGREE TO THE PROVISIONS OF THE CONTRACT FOR POOL CONSTRUCTION, AND APPROVE THESE PLANS WHICH ARE MADE APART OF THAT CONTRACT I OWNERS SIGNATURE ADDRESS: 913 Jackson Way Ft Pierce, FI 34949 AGENT SIGNATURE: 'DANA LAINi LS by G RE The B ache family _ A BARRIER OR ALARM IS NOT A SUBSTITUTE FOR PARENTAL SUPERVISION. NO CHILD SHOULD BE LEFT UNATTENDED. PARENTS SHOULD KNOW THAT ADULT SUPERVISION IS THE ONLY WAY TO PREVENT AN ACCIDENT, THEY SHOULD MAINTAIN CONSTANT EYE CONTACT WTH THE CHILDREN WHENEVER THEY ARE NEAR, OR COULD GET NEAR ANY BODY OF WATER. UNFORTUNATELY, MOST ACCIDENTS OCCUR WHEN THERE IS A LAPSE IN SUPERVISION EVEN FOR A SMALL TIME. NEVERTHELESS, PARENTS SHOULD BE AWARE THAT ANY BODY OF WATER POSES A RISK, ESPECIALLY FOR CHILDREN UNDER 5 YEARS OF AGE, POOLS BY GREG CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH OR INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM WHEN USED BY THE CUSTOMER, FOR ANY REASON BEYOND ITS CONTROL UNDER ANY CIRCUMSTANCES, FOR ANY REASON WHATSOEVER. THE CUSTOMER ASSUMES ALL RISKS DIRECTLY OR INDIRECTLY RELATED TO MALFUNCTIONING OR FAILURE OF BARRIER OR ALARM, POOLS BY GREG, INC. MAKES NO CLAIM WHATSOEVER TO THE DIFFERENCE OF THESE PRODUCTS RULES FOR POOLS > INSTRUCT BABY-SITTERS ABOUT POTENTIAL POOL HAZARDS TO YOUNG CHILDREN N AND ABOUT THE USE OF PROTECTIVE DEVICES SUCH AS DOOR ALARMS AND LATCHES EMPHASIZE THE NEED FOR CONSTANT SUPERVISION. ➢ DURING SOCIAL GATHERINGS AT OR NEAR A POOL APPOINT A DESIGNATED WATCHER TO PROTECT YOUNG CHILDREN FROM POOL ACCIDENTS. ADULTS MAY TAKE TURNS BEING THE WATCHER OTHERWISE, ADULTS MAY BECOME PREOCCUPIED AND ASSUME SOMEONE ELSE IS WATCHING THE CHILDREN. > IF A CHILD IS MISSING, CHECK THE POOL FIRST. SECONDS COUNT IN PREVENTING DEATH OR DISABILITY. 00 TO THE EDGE OF THE POOL AND SCAN THE ENTIRE POOL BOTTOM AND SURFACE, AS WELL AS THE POOL AREA. > DO NOT ALLOW A YOUNG CHILD ON THE POOL WITHOUT AN ADULT. ➢ DO NOT CONSIDER YOUNG CHILDREN TO BE DROWWPROOF BECAUSE THEY HAVE HAD SWIMMING LESSONS OR ARE WEARING A LIFE JACKET. > LEARN CPR, BABY-SITTERSAND OTHER CARETAKERS, SUCH AS GRANDPARENTS AND OTHER SIBLINGS, SHOULD ALSO KNOW CPR ➢ KEEP RESCUE EQUIPMENT BY THE POOL, BE SURE A TELEPHONE IS POOL SIDE WITH EMERGENCY NUMBERS POSTED NEARBY. EQUIPMENT D REMOVED TOYS FROM IN AND AROUND THE POOL WHEN IT IS NOT IN USE. TOYS CAN PAD ATTRACT YOUNG CHILDREN TO THE POOL. PER FBC424.2.22 D NEVER PROP OPEN THE GATE TOAPOOL. > NO RUNNING, PUSHING, WRESTLING OR DISTURBANCE IN THE POOL AREA. NO CHEWING GUM PERMITTED IN THE POOL AREA (RED CROSS SAFETY SUGGESTION FOR THE PREVENTION OF CHOKING). ➢ DON'T LET LONG HAIR GET NEAR A POOL OUTLET. THE SUCTION CAN CAUSE HAIR OR BODY ENTRAPMENT AND DROWNING. > HAVE A FIRST AID KIT AT POOL SIDE. ➢ NEVER SWIM ALONE t, *^ ❑ D NO JUMPING OR DIVING IN THE SHALLOW AREA OF THE POOL. D DON'T ALLOW CHILDREN TO PLAY AS THOUGH THE ARE DROWNING. A FALSE ALARM 1 MIGHT DELAY A RESCUE IN THE EVENT OF A REAL EMERGENCY. > WHEN DIVING, ALWAYS ENTER THE WATER WITH YOUR ARMS EXTENDTD FIRMLY OVERHEAD AND KEEP YOUR HANDS TOGETHER TO PROTECT YOUR HEAD, DIVING INTO SHALLOW WATER CAN RESULT IN CERVICAL SPINE INJURIES CAUSING PERMANENT PARALYSIS. NEVER DIVE INTO AN ABOVEGROUND POOL. > AVOID THE USE OF ALCOHOL OR OTHER DRUGS AROUND WATER. ITp,2VEY E:v-31 S£0 -68 ��� O v,0 �.FrofessloTi111 T'::ne -9 �9 3 a 3S d 7205 Lucie, fi�hle I ��� /fedrt St office: 7 1� I ,. 93 21Z ° a uls IS Sold �� O (22, 303I35 I NOTE: POOL PUMP MOTOR LOCATED ABOVE ELECTRICAL DIAGRAM GRADE. CIRCUIT R PUMP MOTOR(S)AND HEATER(S) ETC (NO SCALE) RAIN TIGHT OUTDOOR NOTE: INSTAi _ELECTRICAL PANEL AMP WEATH (SIZED PER LOAD) DUPLEX RECE r1AIN SERVICE PANEL IN O F I LEAST 10 Avvn. h- - ROVED ONDUIT BRED ouTLEr NOT MORE THAN 20' LOAD) FROM THE INSIDE WALL WIRING TO POOL LIGHT IN TDOOR TIMEt CK OF THE POOL APPROVED CONDUIT UL APPROVED DECK BOX FOR DIRECT CONNECTIO TO WET NICHE NOTES: (1) POOL PANEL AND SWITCHES MUST BE AT LEAST S' FROM THE INSIDE WALL OF THE POOL ° ° (2) ALL ELECTRICAL WIRING AND EQUIPMENT POOL LI HT SWITCH MUST INSTALLED IN ACCORDANCE WITH THE UNDERWATER EITHER INDOOR OR 1999 EDITION OF THE NATIONAL ELECTRICAL LIGHT OUTDOOR CODE APPROVED WIRING IN 1" ° (3) PROVIDE PROPER WORKING CLEARANCE SCH 40 PVC W1 #B SPACES FOR ELECTRICAL EQUIPMENT AS PER BONDING CONDUCTOR HO-26 OF NFPA TO • M1aOC'`Rx L D ET'!�_I! (1.) VENT L.NE TO BE Gi.iNTEii TEcu iiv BETWEEN DRAINS VENT LINE NOI TO i. BE FURTHER THEN • (2.) ANSI / iASME 40 FT. FROM POOL , H DRO-STATIC RELI F DRAIN COVERS 15' MAX. WET LENTH DEVICE INSTALLED I AREAS THAT EXCEED V WATER TABLE IN SHELL TO AIR VENT MINIMUM (2) SUCTION LINES PER PUMP 3 FT. SEPARATION i r 1 F7 1 FILTE P MP- I I - 1) I O GRAVEL BED Aff MAIN DRAIN 2" PVC VENT LINES TO BE 1" MIN 2" MAX PVC APPROVED WITH 424.2.0.E OF THE 2002 FLORIDA BUILDING CODE MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF OEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED+6" F10" MIN. 12" MAX. N.TS. IDR O DING WHERE APPLICABLE #0 GROUND WIRE STEPS • STEP DETAIL 1. TREAD IS MIN. Of 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 40DO PSI. FOOTER DETAIL (2) #3 REBAR OR (1) #5 REBAR 8" 00 8" NO SCALE SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 20' m x. N.T.S. OUTSIDE NOLEOF REPOSE V AND FURT 9' TO 6 .6" HICK WALLS REBAR S WM3 REBAR @12" O.C. WAY EACH W V D' TO 3' w #' THICK WALLS WM3 REBAR @ 12" O.C. EACH W'( 9 It b I ae 3ftJ` / / roi 6/ ESHORIN 13 INTINSTALLEDTTTHE LE OF EXCAVATION AND SHORING I!DULDOSE IS DBE • SHORIEN SUFFICIENT TO SECURE SOILS FROM EROSION ORET • NO UNDERMININGOCCURS OR ENGINEER APPROVVEDD IF IF JY JY DOES TE • COMPACTION TEST OF THE BACKFILLED MARTIAL ARE FDVIDED AT C.O. OF THE SWIMMING POOL (NO SCALE) ALL PLUMBING SCH. 40 PVC. SUCTION SIDE 2" RETURN SIDE 1.5" MAIN F.TER LOCATION OF GFI RECEPTACLE TO BE i DETERMINED IN FIELD PER NEC 660 RAISED AREA ELEV. & GRADE RAISED CONCRETE EXPOSED & TOPPED B t EXISTING GRADE OR 1' TO 4' IESAR POOL PERIMETER SLOPE 03 RERAR 0VERPOUR BEND INTO DECK 114" PER FT SLOPE NOTE:REMOVEGRATE& HELL POINT PLUG FROM MAIN (OR CAPTILI6', WHERE @4$"O,G, MAX. -----► DRAIN& ATTACH AUX. PUMP gPPLICABL LINE WHEN EMPTYING POOL./8'rX8"TIE 1., 4" SLAB INTERIOR - 2500 FIBE GRATE SHALL FINISH TYPICAL WALL BE SECURED IN 4 12" TYP. SECTION & PLACE SO WALL WELL POINT THAT TOOLS (NO SCALE) ARE REQUIRED FOR REMOVAL STEEL-TEX FORM 6" TYP R KRAFT WALL FLOOR A3 @ 12" O.C.B.W. NOTE: FOR DEPTHS 1READE REATER THAN 8' ADD 1- PLUG #3 COVE BAR @ 8" O.C. TO PUMP —10 I, GRAVEUBED a � STATIC WATER OR AIR PRESSURE NO LESS THAN ,1 5 PSI FOR 16 MINUTES. r f19d,1011111 J HAR & LINT C/TCHER (COMPOMNT OF PUMP) PO'IGLPATIO/ WATER LEVEL f'— FROM/ 1. /LIGHT POWER CONDUIT SUPPLY UNDERWATER NICHE LIGHT DETAIL (NO SCALE) NICHE ENCASED IL;'<'. rGROUND CLAMP IN GUNITE ? NTINUOUS BOND WIRE POOL FINISHMMON TO POOL STEEL, RAILS & EQUIPMENT .�. 1 RON OF WATERLINE TILE 13 1,2" O/C E.W. CYCOLAC MAIN (NO SCALE) THESE PLgNS gRESUBJEC gNDALLPROP MAYBE EDBYFIELDNNSPORRECTIODDE NSORK COMPLyWM NquRNC SLZTO ILE COPY WALLS. .. ... -.. .. .. __ _. SHALL NOT SLOPE GREATER 6� THAN 11 BY St. Lucie Cosa S 0 9b a�3 z �n ' v '4 dA L ;old a