HomeMy WebLinkAboutPOOL PLANS6 X 6 WATERLINE TILE
2 X 6 STEP TIL,E___�__�
OVER POUR
HAND HOLDS_
GEM FINISH
BABY BARRIER
i
DECKING ll
AQUA RITES SALT C111LORINAT01
I
I I
WOODEN FENCE
SURIRC►UNDIh' lG YARD
46 ft. 10 in.
EFFECTIVE JANUARY i
FLA. STATUTE CHAPTER 424
REQUIRES ALL SYVII+AM'NG
POOLS TO COVERS, SELF -CLOSING DOC"
OR ALAIiAit SYSTrall's.
LOCATION OF GFI RECEPTACLE TO BE
DETERMINED IN FIELD PER NEC 680
POOL: 393 SI FT. X 81 LF.
DECK: 889 SC FT.
00 B�ol�r�dW1�D
Illme YFO � Y, J .
MUSTEE'�'ND 6ffM
No eItispva II C pd wail oar °oil q SE M.40E
—w-----------------------------------------
--———— — — —
--- 1
® 6 MIL. VISQUEEN
s� I
I I I
I WATER DEPTH AT BOTTOM I
I. I STEP WILL NOT EXCEED 48" I
I, I PER FBC 6.2.2.2
5 fr.. 4ln 1 24 ft. 6; 3'DEEP I
74_ft. 0 in. _
I i TILED
II STEP
L LIGFI(
EDGE �
I a O I
SKIMME
AC ---------- Al
�Nlq
la'
I F
i' ------------------------------
DEEP TILED EDGE Ar�
® SU DECK
I I
I'
KOOL DECK
_____________--
EXISTING PATIO
SAFETY BARRIER IS NOT CLOSER THAN 20" FROM POOL
SAFETY BARRIER PER FBC 424..17.3 AND ANSI/NSPI-6.1995
— i77-----------------------------------------I THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
illy I
BY
St. LucieCour
THE°� HillEN EVER R;VIEWED
I � ; Imf a�ICE WITH THE FLORIDA
e
POOL SPECIFICATIONS I
MAXIMUM WIDTH 21 MAXIMUM LENGTH 24`5"
MINIMUM DEPTH 3 Mawmiu88 efRRTY 5
J
300 WATT
NA
M
UT THERAPY
WITH
I ELECTRICAL HOOKUP ENERGIZED 1
1 MOASICS NO 1
OWNERS HEREBY ASSUME AND AGREE TO THE
PROVISIONS OF THE CONTRACT FOR POOL
CONSTRUCTION, AND APPROVE THESE PLANS
WHICH ARE MADE APART OF THAT CONTRACT
I OWNERS SIGNATURE
ADDRESS: 913 Jackson Way
Ft Pierce, FI 34949
AGENT SIGNATURE: 'DANA LAINi
LS
by
G RE
The B ache family
_
A BARRIER OR ALARM IS NOT A SUBSTITUTE FOR PARENTAL SUPERVISION. NO CHILD
SHOULD BE LEFT UNATTENDED. PARENTS SHOULD KNOW THAT ADULT SUPERVISION IS THE
ONLY WAY TO PREVENT AN ACCIDENT, THEY SHOULD MAINTAIN CONSTANT EYE CONTACT
WTH THE CHILDREN WHENEVER THEY ARE NEAR, OR COULD GET NEAR ANY BODY OF
WATER. UNFORTUNATELY, MOST ACCIDENTS OCCUR WHEN THERE IS A LAPSE IN
SUPERVISION EVEN FOR A SMALL TIME. NEVERTHELESS, PARENTS SHOULD BE AWARE THAT
ANY BODY OF WATER POSES A RISK, ESPECIALLY FOR CHILDREN UNDER 5 YEARS OF AGE,
POOLS BY GREG CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH OR
INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM WHEN USED BY THE
CUSTOMER, FOR ANY REASON BEYOND ITS CONTROL UNDER ANY CIRCUMSTANCES, FOR
ANY REASON WHATSOEVER. THE CUSTOMER ASSUMES ALL RISKS DIRECTLY OR INDIRECTLY
RELATED TO MALFUNCTIONING OR FAILURE OF BARRIER OR ALARM, POOLS BY GREG, INC.
MAKES NO CLAIM WHATSOEVER TO THE DIFFERENCE OF THESE PRODUCTS
RULES FOR POOLS
> INSTRUCT BABY-SITTERS ABOUT POTENTIAL POOL HAZARDS TO YOUNG CHILDREN
N
AND ABOUT THE USE OF PROTECTIVE DEVICES SUCH AS DOOR ALARMS AND LATCHES
EMPHASIZE THE NEED FOR CONSTANT SUPERVISION.
➢ DURING SOCIAL GATHERINGS AT OR NEAR A POOL APPOINT A DESIGNATED WATCHER
TO PROTECT YOUNG CHILDREN FROM POOL ACCIDENTS. ADULTS MAY TAKE TURNS
BEING THE WATCHER OTHERWISE, ADULTS MAY BECOME PREOCCUPIED AND ASSUME
SOMEONE ELSE IS WATCHING THE CHILDREN.
> IF A CHILD IS MISSING, CHECK THE POOL FIRST. SECONDS COUNT IN PREVENTING
DEATH OR DISABILITY. 00 TO THE EDGE OF THE POOL AND SCAN THE ENTIRE POOL
BOTTOM AND SURFACE, AS WELL AS THE POOL AREA.
> DO NOT ALLOW A YOUNG CHILD ON THE POOL WITHOUT AN ADULT.
➢ DO NOT CONSIDER YOUNG CHILDREN TO BE DROWWPROOF BECAUSE THEY HAVE HAD
SWIMMING LESSONS OR ARE WEARING A LIFE JACKET.
> LEARN CPR, BABY-SITTERSAND OTHER CARETAKERS, SUCH AS GRANDPARENTS AND
OTHER SIBLINGS, SHOULD ALSO KNOW CPR
➢ KEEP RESCUE EQUIPMENT BY THE POOL, BE SURE A TELEPHONE IS POOL SIDE WITH
EMERGENCY NUMBERS POSTED NEARBY.
EQUIPMENT
D REMOVED TOYS FROM IN AND AROUND THE POOL WHEN IT IS NOT IN USE. TOYS CAN
PAD
ATTRACT YOUNG CHILDREN TO THE POOL.
PER FBC424.2.22
D NEVER PROP OPEN THE GATE TOAPOOL.
> NO RUNNING, PUSHING, WRESTLING OR DISTURBANCE IN THE POOL AREA. NO
CHEWING GUM PERMITTED IN THE POOL AREA (RED CROSS SAFETY SUGGESTION FOR
THE PREVENTION OF CHOKING).
➢ DON'T LET LONG HAIR GET NEAR A POOL OUTLET. THE SUCTION CAN CAUSE HAIR OR
BODY ENTRAPMENT AND DROWNING.
> HAVE A FIRST AID KIT AT POOL SIDE.
➢ NEVER SWIM ALONE
t, *^
❑
D NO JUMPING OR DIVING IN THE SHALLOW AREA OF THE POOL.
D DON'T ALLOW CHILDREN TO PLAY AS THOUGH THE ARE DROWNING. A FALSE ALARM
1
MIGHT DELAY A RESCUE IN THE EVENT OF A REAL EMERGENCY.
> WHEN DIVING, ALWAYS ENTER THE WATER WITH YOUR ARMS EXTENDTD FIRMLY
OVERHEAD AND KEEP YOUR HANDS TOGETHER TO PROTECT YOUR HEAD, DIVING INTO
SHALLOW WATER CAN RESULT IN CERVICAL SPINE INJURIES CAUSING PERMANENT
PARALYSIS. NEVER DIVE INTO AN ABOVEGROUND POOL.
> AVOID THE USE OF ALCOHOL OR OTHER DRUGS AROUND WATER.
ITp,2VEY E:v-31 S£0 -68 ��� O
v,0 �.FrofessloTi111 T'::ne -9 �9 3 a 3S d
7205 Lucie,
fi�hle
I ��� /fedrt St office:
7 1� I ,. 93 21Z ° a uls IS Sold
�� O (22, 303I35 I
NOTE: POOL PUMP MOTOR LOCATED ABOVE
ELECTRICAL DIAGRAM GRADE. CIRCUIT R
PUMP MOTOR(S)AND HEATER(S) ETC
(NO SCALE)
RAIN TIGHT OUTDOOR NOTE: INSTAi
_ELECTRICAL PANEL AMP WEATH
(SIZED PER LOAD) DUPLEX RECE
r1AIN SERVICE PANEL IN
O F I
LEAST 10 Avvn. h- -
ROVED ONDUIT BRED
ouTLEr
NOT MORE THAN 20'
LOAD)
FROM THE INSIDE WALL
WIRING TO POOL LIGHT IN
TDOOR TIMEt CK OF THE POOL
APPROVED CONDUIT
UL APPROVED DECK BOX
FOR DIRECT CONNECTIO
TO WET NICHE
NOTES:
(1) POOL PANEL AND SWITCHES MUST BE AT
LEAST S' FROM THE INSIDE WALL OF THE POOL
°
°
(2) ALL ELECTRICAL WIRING AND EQUIPMENT
POOL LI HT SWITCH
MUST INSTALLED IN ACCORDANCE WITH THE
UNDERWATER EITHER INDOOR OR
1999 EDITION OF THE NATIONAL ELECTRICAL
LIGHT OUTDOOR
CODE
APPROVED WIRING IN 1" °
(3) PROVIDE PROPER WORKING CLEARANCE
SCH 40 PVC W1 #B
SPACES FOR ELECTRICAL EQUIPMENT AS PER
BONDING CONDUCTOR
HO-26 OF NFPA TO
•
M1aOC'`Rx L D ET'!�_I!
(1.) VENT L.NE TO BE
Gi.iNTEii
TEcu iiv
BETWEEN DRAINS
VENT LINE NOI TO
i.
BE FURTHER THEN
•
(2.) ANSI / iASME
40 FT. FROM POOL
,
H DRO-STATIC RELI F
DRAIN COVERS
15' MAX. WET LENTH
DEVICE INSTALLED I
AREAS THAT EXCEED V
WATER TABLE IN SHELL
TO AIR VENT
MINIMUM (2)
SUCTION LINES PER
PUMP 3 FT. SEPARATION
i
r
1
F7
1
FILTE P MP- I I - 1) I O GRAVEL BED
Aff MAIN DRAIN 2" PVC
VENT LINES TO BE 1" MIN 2" MAX PVC
APPROVED WITH 424.2.0.E OF THE 2002 FLORIDA
BUILDING CODE
MISC. NOTES
1. ALL STEPS AND SWIMOUT BENCH EDGES
WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE
COLOR OF OEM FINISH FOR VISIBILITY
2. HAND HOLD TO BE INSTALLED AT ARE
WHERE DECK RAISED+6"
F10" MIN.
12" MAX.
N.TS.
IDR O DING
WHERE APPLICABLE
#0 GROUND WIRE
STEPS
• STEP DETAIL
1. TREAD IS MIN. Of 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN
(3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID GUNITE 40DO PSI.
FOOTER DETAIL
(2) #3 REBAR OR
(1) #5 REBAR
8" 00
8"
NO SCALE
SWIMOUTS
WHEN PROVIDED
SHALL BE AT 20" MAX.
BELOW THE
WATERLINE
20' m x.
N.T.S.
OUTSIDE NOLEOF REPOSE
V AND FURT
9' TO 6 .6" HICK WALLS REBAR S WM3 REBAR @12" O.C. WAY
EACH W V
D' TO 3' w #' THICK WALLS WM3 REBAR @ 12" O.C. EACH W'(
9 It
b I
ae 3ftJ`
/
/ roi
6/
ESHORIN 13 INTINSTALLEDTTTHE LE OF EXCAVATION AND SHORING I!DULDOSE IS DBE
• SHORIEN
SUFFICIENT TO SECURE SOILS FROM EROSION ORET
• NO UNDERMININGOCCURS OR ENGINEER APPROVVEDD IF IF JY JY DOES
TE
• COMPACTION TEST OF THE BACKFILLED MARTIAL ARE FDVIDED AT C.O.
OF THE SWIMMING POOL
(NO SCALE)
ALL PLUMBING SCH. 40
PVC. SUCTION SIDE 2"
RETURN SIDE 1.5"
MAIN
F.TER
LOCATION OF GFI RECEPTACLE TO BE i
DETERMINED IN FIELD PER NEC 660
RAISED AREA ELEV. & GRADE
RAISED CONCRETE
EXPOSED & TOPPED
B
t EXISTING GRADE
OR 1' TO 4'
IESAR POOL PERIMETER SLOPE
03 RERAR
0VERPOUR
BEND INTO DECK 114" PER FT SLOPE
NOTE:REMOVEGRATE&
HELL POINT PLUG FROM MAIN
(OR CAPTILI6',
WHERE
@4$"O,G, MAX. -----►
DRAIN& ATTACH AUX. PUMP
gPPLICABL
LINE WHEN EMPTYING POOL./8'rX8"TIE
1.,
4" SLAB
INTERIOR
-
2500 FIBE
GRATE SHALL
FINISH
TYPICAL WALL
BE SECURED IN
4
12" TYP. SECTION &
PLACE SO
WALL WELL POINT
THAT TOOLS
(NO SCALE)
ARE REQUIRED
FOR REMOVAL
STEEL-TEX FORM
6" TYP
R KRAFT WALL
FLOOR
A3 @ 12" O.C.B.W.
NOTE: FOR DEPTHS
1READE
REATER THAN 8' ADD 1-
PLUG #3 COVE BAR @ 8" O.C.
TO PUMP —10
I, GRAVEUBED
a �
STATIC WATER OR AIR
PRESSURE NO LESS THAN
,1 5 PSI FOR 16 MINUTES.
r
f19d,1011111
J HAR & LINT
C/TCHER
(COMPOMNT OF PUMP)
PO'IGLPATIO/
WATER LEVEL f'—
FROM/
1. /LIGHT
POWER
CONDUIT
SUPPLY
UNDERWATER
NICHE
LIGHT DETAIL
(NO SCALE)
NICHE ENCASED IL;'<'. rGROUND CLAMP
IN GUNITE ? NTINUOUS BOND WIRE
POOL FINISHMMON TO POOL STEEL,
RAILS & EQUIPMENT
.�. 1 RON OF WATERLINE TILE
13
1,2" O/C E.W.
CYCOLAC MAIN
(NO SCALE)
THESE PLgNS
gRESUBJEC gNDALLPROP
MAYBE EDBYFIELDNNSPORRECTIODDE
NSORK
COMPLyWM NquRNC SLZTO
ILE COPY
WALLS. .. ... -.. .. .. __ _.
SHALL
NOT
SLOPE
GREATER 6�
THAN 11
BY
St. Lucie Cosa
S 0 9b a�3
z �n ' v
'4 dA L ;old
a