NOTICE OF ACCEPTANCE
Decra Roofing Systems Inc.
1230 Railroad St.
Corona, CA 92882
,SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Decr` atoof�S Decra Tile, Decra Shake, Decra Shake Plus, & Decra Shingle Plus
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA N 03-1028.03 and consists of pages 1 through 11.
The submitted documentation was reviewed by Frank Zuloaga, RRC
O""' —007-5- NOA No 04-0831.01
` Expiration Date: 01/25/09
0 11 L Approval Date: 05/19/05 C YPage 1 of 11
z`dO
ROOFING SYSTEM APPROVAL:
Category
Roofing
Sub -Category:
Metal, Panels (Non -Structural)
Material:
Steel
Deck Type:
Wood
Maximum Design Pressure
-1425 psf (See General Limitations #1)
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Test
Product
Product
Dimensions
Specifications
Description
Decra Tile
Width=161/2"
PA 110
Corrosion resistant, coated, preformed,
Length = 52 1/4"
metal panels in a the profile.
Thickness = 0.0179
Decry Shake
Width=14-%z"
PA 110
Corrosion resistant, coated, preformed,
Length = 53 '/,"
metal panels simulating a shake profile
Thickness = 0.0179
Decra Shingle Plus
Length = 1521s"
PA 110
Corrosion resistant, coated, preformed,
Width = 51-%"
metal panels simulating a shake profile
Thickness = 0.0179
Decry Shake Phis
Length = 15-'/:"
PA 110 -
Corrosion resistant, coated, preformed,
Width = 53- h"
metal panels simulating a shake profile
Thickness = 0.0179
Trim Pieces
1= varies
PA 110
Standard flashing and trim pieces
w = varies
Thickness = 0.0179
TRADE NAMES OF PRODUCTS MANUFACTURED OTBERS
Product Dimensions Test Product Description Manufactnrer
Specifications
Fasteners min. #8 x 11/a" PA 114 Pan head wood screws generic
(Plywood Deck or Appendix E or annular ring shank
into Wood Truss) min. 12 ga. hot dipped electro or
mechanically gale.
roofing nails for
attachment of plywood
deck to wood trusses
Wood Battens 2" x 2" Grading Rule Southern Pine Select #2, generic
Agency SPiB or equivalent with a
specific gravity of 0.55
or better.
NOA No 04-MI.01
Expiration Date: 01/25/09
Approval Date: 05/19/05
Page 2 of 11
Nails
No. 16d x 3%"
PA 114
Corrosion resistant,
generic
(Batten
long x 0.131"
Appendix E
coated steel nails for
Approved
Attachment)
diameter
batten installation
manufacturer
Screws
No. 8 x 3 1/2"
PA 114
Corrosion resistant,
generic
(Batten
long x 0.126"
Appendix E
Phillips flat head coated
Approved
Attachment)
diameter
steel screws for batten
manufacturer
installation
Sealant
N/A
N/A
Sealant for use at foam
generic
closure strip.
Valley Flashing
min. 26 ga.
ASTM A 525
Galvanized steel valley
generic
min. 16" width
flashing
Screws ( Panel
Hextta No. 12 x
PA 114
Corrosion resistant, hex
171W Buildex
attachment for all
1 W long
Appendix E
head, sheet metal screws
panels)
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name /Report
Date
Underwriters Laboratories Inc.
03CA11899
UL 580
Oct. 2003
PRI Asphalt Technologies
TARI-004-02-01
TAS 110
Mar. 2003
PRI Asphalt Technologies
TARI-005-02-01
TAS 110
Mar. 2003
PRI Asphalt Technologies
TARI-006-02-01
TAS 110
Mar. 2003
The Center for Applied Engineering,
MTS 25-7248B
ASTM G 26
Aug.,1990
The Center for Applied Engineering,
No. 307WMDC
PA 100
April, 1995
The Center for Applied Engineering,
MTS 25-7248A
ASTM B 117 "
Aug., 1995
Western Fire Center, Inc.
Project No. 95022 Fire Resistance ASTM E 108June, 1995
The Center for Applied Engineering,
MTS 25-7248A
ASTM B 117
Aug., 1995
The Center for Applied Engineering,
MTS 25-7248B
ASTM G 26
Aug.,1990
The Center for Applied Engineering,
MDC-124 & 127
April, 1995
United States Testing Co., Inc.
187260-1 & 2
ASTM E 108
April, 1992
United States Testing Co., Inc.
187853-1 '
ASTM E 108
June, 1993
Western Fire Center, Inc.
Project No. 95022
ASTM E 108
Jung 1995
NOA No 044831.01
'r 1?apiration Date: OV25/09
Approval Date: 05/19/05
Page 3 of 11
APPROVED SYSTEMS
SYSTEM A-1: Decra Shake & Decra Tile (installed on battens)
Deck Type: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank. For re -roof applications, refer below.
Slope Range: In accordance with applicable Building Code. .
Maximum Uplift
Pressure: The maximum allowable uplift pressure for System A-1 shall be -75 psf (See
General Limitations #1).
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than
# 8 x 2 Yx" long screws spaced 6" O.C. In reroofing, where the deck is less than
thick (Minimum 1$/„^) The above attachment method must be in addition to
existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type B installed with a
minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with
corrosion resistant tin -caps and 12 gauge 1 '/<" annular ring -shank nails, spaced
6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any
Miami -Dade County Product Control Approved underlayment having a current
NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Or for class A or B fire rating,
install minimum 1l/a" thick Georgia Pacific "Dens Deck" (with current NOA) or
minimum 4mm thick of Tritex, RockRoof (with current NOA) or s/8" water
resistant type X gypsum sheathing with treated core and facer.
Eave Termination Eave metal drip edge shall be installed in a 1/8" continuous bed of approved
ASTM 4586 flashing cement with sealed laps. Eave metal drip edge shall be
fastened to deck at 4" o.c. in accordance with RAS 111.
Battens: Install minimum 2" x 2" wood battens over underlayment, running perpendicular
to the roof slope, at a maximum spacing of 12ils" for the Decra Shake, or 14-%:
"o.c. for the Decra Tile. Attach wood battens through deck to wood trusses
spaced 24" o.c. with two approved 16d nails at each rafter or truss.
Valleys: Valley construction shall be as detailed in Decra Roofing Systems Inc. current
published specifications, and incompliance with the minimum requirements
provided in RAS 133.
Metal Panels and
Accessories: Install the "Decra Shake or Tile" and accessories in compliance with Decra
Roofing Systems Inc current, published installation instructions and details.
Flashing, penetrations, valley construction and other details shall be constructed
in compliance with the minimum requirements provided in RAS 133. Panels
fastened to battens with approved Hextra No. 12 x 1 '/s" long screws driven into
the (lower) butt edges course and upper edge of adjacent lower course spaced 7
inches o.c. Four approved screws for each full panel.
o NOA No 04-0831.01
Expiration Date: 01/25/09
Approval Date: 05/19/05
Page 4 of 11
System A-2: Decra Shake or Shake Plus & Decra Tile or Shingle Plus (installed on battens)
Deck Type: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank. For re -roof applications, refer below.
Slope Range: In accordance with applicable Building Code.
Maximum Uplift
Pressure: The maximum allowable uplift pressure for System A-1 shall be —142.5 psf (See
General Limitatioms#1).
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than
# 8 x 2 VV long screws spaced 4" O.C. In reroofing, where the deck is less than
:e/32" thick (Minimum "/32") The above attachment method must be in addition
to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a
minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with
corrosion resistant tin -caps and 12 gauge 1 %" annular ring -shank nails, spaced
6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any
Miami -Dade County Product Control Approved underlayment having a current
NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Or for class A or B fire rating,
install minimum''/<" thick Georgia Pacific "Dens Deck" (with current NOA) or
minimum 4mm thick of Tritex, RockRoof (with current NOA) or 5/s" water
resistant type X gypsum sheathing with treated core and facer.
Eave Termination Eave metal drip edge shall be installed in a I/s" continuous bed of approved
ASTM 4586 flashing cement with sealed laps. Eave metal drip edge shall be
fastened to deck at 4" o.c. in accordance with RAS 111.
Counter Battens: Install minimum 1 x 4 inch counter battens fastened over underlayment, (and/or
fire barrier) through the wood deck into the joist or trusses spaced 24 inches o.c.
Counter battens shall be spaced at 24 inches o.c. and fastened with 16d by 3-%"
long corrosive resistant twist shank nails. Twist shank nails shall be fastened 7
inches o.q along the entire length of the counter batten.
Horizontal Batten: Install minimum 2" x 2" wood battens over counter battens, running
perpendicular to the roof slope, at a maximum spacing of of 12-5/g" for the Decra
Shake or Shake Plus, or 14-%2 "o.c. for the Decra Tile or Shingle P1us.Attach
wood battens trough deck and counter battens'to the joists or trusses using two
#10 x 3-%" long wood screws at each batten intersection.
o NOA No 04-OS31.01
Expiration Date: O1/25/09
Approval Date: 05/19/05
Page 5 of 11
Valleys: Valley construction shall be as detailed in Deem Roofing Systems Inc current
published specifications, and in compliance with the minimum requirements
provided in RAS 133.
Metal Panels and
Accessories: Install the Decra Shake Plus or Decra Shingle Plus and accessories in
compliance with Decra Roofing Systems Inc current, published installation
instructions and details. Flashings, penetrations, valley construction and other
details shall be constructed in compliance with the minimum requirements
provided in RAS 133. Panels shall be fastened to battens with No. 10 x I W
long corrosion resistant screws driven into the (lower) butt edge course spaced 6
inches o.c for a total of eight screws for each full panel.
NOA No 04-0831.01
0 Expiration Date: O1/25109
Approval Date: 05/19/05
Page 6 of 11
SYSTEM A-3: Decra Shake Plus & Decra Shingle Plus (direct to deck)
Deck Type: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank. For re -roof applications, refer below
Slope Range: In accordance with applicable Building Code.
Maximum Uplift
Pressure: The maximum allowable uplift pressure for System A-1 shall be -102 psf (See
General Limitations #1).
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than
# 8 x 2 '/z" long screws spaced 4" O.C. In reroofing, where the deck is less than
19/32" thick (Minimum rs/32") The above attachment method must be in addition
to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a
minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with
corrosion resistant tin -caps and 12 gauge 1 VV annular ring -shank nails, spaced
6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any
Miami -Dade County Product Control Approved underlayment having a current
NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Or for class A or B fire rating,
install minimum'/a" thick Georgia Pacific "Dens Deck" (with current NOA) or
minimum 4mm thick of Tritex, RockRoof (with current NOA) or °/s" water
resistant type X gypsum sheathing with treated core and facer.
Eave Termination Eave metal drip edge shall be installed in a'/a" continuous bed of approved
ASTM 4586 flashing cement with sealed laps. Eave metal drip edge shall be
fastened to deck at 4" o.c. in accordance with RAS 111.
Valleys: Valley construction shall be as detailed in Deem Roofing Systems Inc current
published specifications, and in compliance with the minimum requirements
provided in RAS 133.
Metal Panels and
Accessories: Install the Decra Shake Plus or Decra Shingle Plus and accessories in
compliance with Decra Roofing Systems Inc current, published installation
instructions and details. Flashings, penetrations, valley construction and other
details shall be constructed in compliance with the minimum requirements
provided in RAS 133.
Install a 1 x 4 inch wood starter batten at the eave fastened to wood deck with
410 x 1-'/z inch long corrosion resistant wood screws spaced six inches o.c.
Panels fastened to starter strip and wood deck with No. 10 x 1 W' long corrosion
resistant screws driven into the (lower) butt edge course spaced 6 inches o.c for a
total of eight screws. And eight additional screws in the back end of each panel
fastened to the deck for a total of sixteen screws per each full panel. (See detail
drawing herein)
NOA No 04-0831.01
Expiration Date: 01/25/09
Approval Date: 05/19/05
Page 7 of 11
GENERAL LOUTAT1ONs
1. The maximum designed pressure listed herein shall be applicable to all roof pressure zones O.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers).
2. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following
statement: "Miami -Dade County Product Control Approved."
3. Any modifications to this Notice of Acceptance shall void such approval.
o ' NOA No 04-0831.01
Expiration Date: 01/25/09
Approval Date: 05/19/05
Page 8 of 11
16-
Detail Drawings
Decra Tile
8 Fastener installation
Ir— 52-1/4" �I
Decra Shake
8 Fastener Installation
NOA No 04-0831.01
Expiration Date: O1/25/09
Approval Date: 05/19/05
0 Page 9 of 11
Decra Shake Plus
16 Fastener Installation
Decra Shingle Plus
16 Fastener Installation
15.875"