Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
File COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES- 1780 B MODEL Builder Name: ADAMS HOMES SCANNED Street: 5321 SAN BENDETTO PLACE Permit Office: ST LUCIE COUNTY BY City, State, Zip: FORT PIERCE, FL, Permit Number: L+i. Lucie St. Owner: Jurisdiction: ST LUCIE COUNTY L V l Count Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1837.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1487.00 ft2 b. Frame- Wood, Adjacent R=11.0 350.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft, 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1780.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1780.00ft- 6. Conditioned floor area above grade (W) 1780 b. N/A R= ft' Conditioned floor area below grade (1112) 0 c. N/A R= ff 11. Ducts R ft' 7. Windows (162.9 scift.) Description Area a. Sup: Attic, Reb Attic, AH: AHU CLST 6 150 a. U-Factor: Sgl, U=0.65 162.87 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 27.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1780.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft- b. Conservation features EF: 0.980 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.091 Total Proposed Modified Loads: 56.42 PASS Total Baseline Loads: 59.56 I hereby certify that the plans and specifications covered by Review of the plans and STq?F this calculation are in compliance with the Florida Energy specifications covered by this OF'Ci1H Code. calculation indicates compliance with the Florida Energy Code. h mro-'-:-:;5!l^=•',••""`n0 PREPARED BY: 1 I SL�Q�Q (,J Before construction is Completed DATE: 4-30-1 T- this building will be inspected for compliance with Section 553.908 � IV I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. Op WE 1�J - OWNER/AG NT: J 7� v BUILDING OFFICIAL: DATE: /3O Ict DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/29/2019 12:43 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ADAMS HOMES- 1780 B MO Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1780 Lot # Owner Name: - Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5321 SAN BENDETTO Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Emsting: New (From Plans) Comment: CLIMATE / Design Temp Inl Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1780 17172 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 OWNERS BEDRO 261 2610 No 0 1 1 Yes Yes Yes 2 O LINEN 20 160 No 0 1 Yes Yes Yes 3 0 BATH 113 904 No 0 1 Yes Yes Yes 4 O WIC 70 560 No 0 1 Yes Yes Yes 7 5 BEDROOM 2 150 1500 No 0 1 1 Yes Yes Yes 6 CLST 2 18 144 No 0 1 Yes Yes Yes 7 CLST 3 12 96 No 0 1 Yes Yes Yes 8 BATH 2 45 360 No 0 1 No Yes Yes 9 BEDROOM 3 136 1360 No 0 1 1 Yes Yes Yes 10 LAUNDRY 49 490 No 0 1 No Yes Yes 11 HALLWAY 84 840 No 0 1 No Yes Yes 12 AHU CLST 12 96 No 0 1 No Yes Yes 13 STORAGE 24 192 No 0 1 No Yes Yes 14 FAMILY 342 3420 No 0 1 Yes Yes Yes 15 KITCHEN 180 1800 Yes 0 1 Yes Yes Yes 16 FOYER 105 1050 No 0 1 Yes Yes Yes 17 DINING 159 1590 No 0 1 Yes Yes Yes 4/29/2019 12:43 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation OWNERS BEDR 32 ft 0 261 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation O LINEN 5 ft 0 20 ft2 ___- 1 0 0 3 Slab -On -Grade Edge Insulation O BATH 1811 0 113 ft2 ____ 1 0 0 4SIab-On-Grade Edge Insulation O W IC 6 ft 0 70 ft2 __-_ 1 0 0 5Slab-On-Grade Edge Insulation BEDROOM 2 10 ft 0 150 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation CLST2 aft 0 18 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation CLST3 2ft 0 12 ft2 -_-- 1 0 0 8 Slab -On -Grade Edge Insulation BATH 2 1 ft 0 45 ft2 ___ 1 0 0 9SIab-On-Grade Edge Insulation BEDROOM 3 10 ft 0 136 ft2 __-- 1 0 0 1081ab-On-Grade Edge Insulation LAUNDRY 1 fl 0 49 ft2 ___ 1 0 0 11SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 84 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 12 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation STORAGE 1 ft 0 24 ft2 ___ 1 0 0 14SIab-On-Grade Edge Insulation FAMILY 26 it 0 342 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation KITCHEN 12 ft 0 180 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation FOYER 5 ft 0 105 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation DINING 26.4 ft 0 159 ft2 ____ 1 0 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1991 ft2 0 ft2 Medium 0.6 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft2 N N 4/29/2019 12:43 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) OWNERS BEDR 30 Blown 261 ft2 0.1 Wood _ 2 Under Attic (Vented) OLINEN 30 Blown 20 ft- 0.1 Wood _ 3 Under Attic (Vented) OBATH 30 Blown 113 ft2 0.1 Wood 4 Under Attic (Vented) OWIC 30 Blown 70 ft2 0.1 Wood _ 5 Under Attic (Vented) BEDROOM 2 30 Blown 150 ft2 0.1 Wood 6 Under Attic (Vented) CLST2 30 Blown 18 ft2 0.1 Wood _ 7 Under Attic (Vented) CLST3 30 Blown 12 ft2 0.1 Wood 8 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood _ 9 Under Attic (Vented) BEDROOM 30 Blown 136 ft2 0.1 Wood _ 10 Under Attic (Vented) LAUNDRY 30 Blown 49 ft2 0.1 Wood 11 Under Attic (Vented) HALLWAY 30 Blown 84 ft2 0.1 Wood _ 12 Under Attic (Vented) AHU CLST 30 Blown 12 ft2 0.1 Wood _ 13 Under Attic (Vented) STORAGE 30 Blown 24 ft2 0.1 Wood 14 Under Attic (Vented) FAMILY 30 Blown 342 ft2 0.1 Wood _ 15 Under Attic (Vented) KITCHEN 30 Blown 180 ft2 0.1 Wood 16 Under Attic (Vented) FOYER 30 Blown 105 ft2 0.1 Wood 17 Under Attic (Vented) DINING 30 Blown 159 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 SW Exterior Concrete Block -Exl lnsOWNERS BE 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 2 NW Exterior Concrete Black -Ext InsOWNERS BE 4.1 18 0 10 0 180.0 ft2 0 0 0.6 0 3 NW Exterior Concrete Block -Ext Insul OLINEN 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 4 NE Exterior Concrete Block - Ext Insul O BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NW Exterior Concrete Block - Ext Insul O BATH 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 _ 6 NE Exterior Concrete Block- Ext Insul O W IC 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 7 SW Exterior Concrete Block - Ext InsOEDROOM 2 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 _ 8 SW Exterior Concrete Block - Ext Insul CLST 2 4.1 3 0 8 0 24.0 ft2 0 0 0.6 0 9 SW Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 _ 10 SW Exterior Concrete Block - Ext InstBEDROOM 3 4.1 10 0 10 0 100.0 f12 0 0 0.6 0 11 SE Garage Frame- Wood BEDROOM 3 11 13 0 10 0 130.0 ft2 0 0.25 0.6 0 12 SE Garage Frame -Wood LAUNDRY 11 7 0 10 0 70.0 ft2 0 0.25 0.6 0 _ 13 NE Exterior Concrete Block- Ext Insul FAMILY 4.1 19 0 10 0 190.0 f12 0 0 0.6 0 14 NW Exterior Concrete Block - Ext Insul FAMILY 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 15 NE Exterior Concrete Block- Ext Insul KITCHEN 4.1 12 0 10 0 120.0 f12 0 0 0.6 0 _ 16 BE Exterior Concrete Block- Ext Insul FOYER 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 17 SW Garage Frame - Wood FOYER 11 15 0 10 0 150.0 ft2 0 0.25 0.6 0 18 NE Exterior Concrete Block -Ext Insul DINING 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 19 E Exterior Concrete Block -Ext Insul DINING 4.1 4 3 10 0 42.5 ft2 0 0 0.6 0 20 SE Exterior Concrete Block -Ext Insul DINING 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 21 S Exterior Concrete Block -Ext Insul DINING 4.1 4 3 10 0 42.5 ft2 0 0 0.6 0 4/29/2019 12:43 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornl Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening _ 1 2 3 _ 4 5 6 _ 7 8 9 NW 2 Metal SW 7 Metal SW 10 Metal NE 13 Metal NW 14 Metal NE 18 Metal E 19 Metal SE 20 Metal S 21 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 0.65 0.25 N 30.0 W 2 ft 0 in 1 It 4 in 15.0 ft2 2 ft 0 in 1 ft 4 in 15.0 ft2 2 fl0 in 1 It 4 in 30.0 ft2 2 ft 0 in 1 ft 4 in 17.9 ft2 2 fl0 in 1 ft 4 in 15.0 ft2 2 ft 0 in 1 It 4 in 10.0 ft2 2 ft 0 in 1 it 4 in 20.0 112 2 ft 0 in 1 ft 4 in 10.0 ft2 2 It 0 in 1 It 4 in None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 35 It 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000429 2003.4 109.98 206.84 .3289 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 27 kBtu/hf 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 35 kBtu/hr 1050 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None Lj 4/29/2019 12:43 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS / ---- Supply-- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool 1 Attic 6 150 ft' Attic 15 ft' Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programabler[T']hermostat[[: CFans: ]]N Heating Jan [X] Feb r[�x]'] Mar Apr[[eilliing 44MayX]] i[�] Jul�[X]] 4 ]] Sep[ ri [[X]] N Nov Nov Doc, H Venting I 1 Jan [[ 11 Feb L 1 [Xl Mar Lxl Apr [ ] May L 1 Jun [ ] Jul [ ] Aug Sep Oct Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 fib 68 PM 68 68 68 68 fib 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft. Oft 0.3 OWNERS BEDRO Default(8 lbs/sq.ft. ft. ft 0.3 O LINEN Default(8 lbs/sq.ft. ft' It 0.3 O BATH Default(8 lbs/sq.ft. ft' ft 0.3 O W IC Default(8 lbs/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 CLST 2 Default(81bs/sq.ft. W ft 0.3 CLST 3 Default(8 lbs/sq.ft. ft' ft 0.3 BATH 2 Default(S lbs/sq.ft. fP ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Defaull(8 lbs/sq.ft. ft' ft 0.3 HALLWAY Default(81bs/sq.ft. IF ft 0.3 AHU CLST Default(8 lbs/sq.ft. fl' ft 0.3 STORAGE Default(81bs/sq.ft. ft. ft 0.3 FAMILY Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. fl' ft 0.3 FOYER Default(8 lbsls.ft. fl' ft 0.3 DINING Name: Signature: Rating Compant: Date: 4-30A9 4/29/2019 12:43 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1780 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c) Area 7c. 162.9 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Cade, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. BuilderSignatut�� Q 4taY-rC-rZ Date: 6ALZOAft Address of New Home: 5321 SAN BENDETTO PLACE City/FL Zip: FORT PIERCE. FL 4/2912019 12:44:02 PM EnergyGauge@ USA 6.0.02 - FaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ST LUCIE COUNTY Permit #: Job Information Builder: ADAMS HOMES Community: Lot: NA Address: 5321 SAN BENDETTO PLACE City: FORT PIERCE State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The building or.dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at pressure of 0.2 Inch w.g. (50'Pascals) in Climate Zones 1;and 2: Q PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakagerate of not exceeding the selected ACH(50) value; as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, subsection ACH50: ACH(50) specified on Form R405-2017-Energy Cold (Performance) or R406-2017 (ERI):. 7.000 x 60 = 17172 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS Code 0 software calculated ❑ When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(D, (g), or (i) or an approved third parry. A written report of the results of the test shall be signed by the parry conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the lest, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 4/29/2019 12:44:28 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ADAMS HOMES- 1780 B MODEL Builder Name: ADAMS HOMES Street: 5321 SAN BENDETTO PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner: Jurisdiction: ST LUCIE COUNTY w= Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls Thejunction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Thejunction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvenled crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind vining and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plate,s and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of IL;(;-4DD. 4/29/2019 12:44 PM EnergyGauge(D USA FBC 6lh Edition (2017) Compliant Software Page 1 of 1 wrightsoft` Pro ect Summary Job: 17a09,2019 ' 7 MODELDate: Apr 22019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Emit: OUICKCALCS@AOL.COM For. ADAMS HOMES 5321 SAN BENDETTO PLACE, FORT PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19256 Btuh Structure 18332 Btuh Ducts 5651 Btuh Ducts 8093 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24907 Btuh Use manufacturers data IT Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25104 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3891 Btuh Ducts 2188 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 1780 1780 Equipment latent load 6079 Btuh Volume (ft3) 17172 17172 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 31182 Btuh Equiv. AVF (cfm) 109 57 Req. total capacity at 0.70 SHR 3.0 ton Heatirig Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3600GOBO Cond CH14NBO3600GOBO AHRI ref 9162518 Coil FX4DNF049L 9162518 Efficiency 8.5 HSPF E icency 12.5 EER, 15 SEER Heating input Sensible cooling 24500 Btuh Heating output 34000 Btuh @ 47'F Latent cooling 10500 Btuh Temperature rise 27 OF Total cooling 35000 Btuh Actual air flow 1167 cfm Actual air flow 1167 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Capacity balance point = 34 OF Backup: Input = 7 kW, Output = 22263 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoR- 2019-Apr-29 12:36:26 RightSuite® Universal 2018 18.0.31 RSU08101 Page 1 ...ADAMS HOMES. 1780 B MODELSAN BENDETTO 5321.rup Calc = MJ8 Front Door faces; SE wrightsoft' Right-J@ Worksheet Job: 1780 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House OWNERS BEDROOM 2 E posed wall 155.4 1t 32.0 If 3 Room height 9.6 1t 10.0 it heat/ccol 4 5 Room dimensions Room area 1780.0 ft2 1.0 x 261.5 it 261.5 ft2 Ty Construction U-value Or HTM Area (1`12) Load Area (ft2) Load number (Btuh/ft2-F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross WP/S Heat Cool 6 VN L43 13A46cs 2g1azirg,clrlowe 13A-0 0.1 0.650 0.143 ne nee e' 4.00 __.18.20 4.00 � 219 -. 26.88 219 '512 _____45 42 - '467 .. ___0 32 1870 _819_ 130 '----1022 _ _12 71gcs 71 --�� �--�0 �.. __ 0 0 ����- -0 __., -.. 0 0 0 _ 0 ' "0 _ 0 _.G W L--G, 2glazina, clr low-e_-, 13A-4ocs __. __0.650 0.143 _ e se- 18.20 ---4.00 _32.42 2.19 ____10 -140 1 -- 100 182 ' _-400 324 -�-- 219 0 - - -0 0 -' - --0 0 _..__. _0 0 .__ _ _ _0 2 glazing, clr Iowa 11D0 13A-4ocs 2 glazing, clrlava _ 13AAocs 0.650 _ . 0.390 0.143 _ _0.650 0.143 as _se_ s a- sw 18.20 _ 10.92._ 4.00 _,18 20 4,00 21.07 10.34 219 _ 14.99 2.19 '20 _._ __..20 42 10 380 10 .,_20 32 _ _ 10 350 364 -__219 130 _ 182 1401 421 208 71 150 -- 766 0 -_. __0 0 0 - 140 0 .__ ___0 0 0 140 0 -_ , _0 0 _ _ 0 561 0 --�---0 0 - --306 W ! -G W, �.._ . V)J 2glazing, clr Iowa _ 13A-4ocs 2 glazing, clr Iowa ._. 0.650 0.143 0.650 sw. nw nw _ 18.20 4.00 1820 - .21.07 2.19 26.88 _ _30 370 30 _ - __15 322 0 _ ___546 1290 546 ____ 632 705 806 ..-. --0 180 30 _ ._.0 150 0 _._ .0 601 546 ___,0 328 806 C-_ 2 glazing, clr,low-e 16B30ad __ _ _0.650 -0.032 rnq_ - _ _ _ 18.20 _ - _0.90 26.88 -� 1.60 _ - __ 18 _ 1780 _ _ __ 0 ._ _ 1780 _ _ 325 �7595 ._- 480 _ 2848. 0 �._ 262 -.._ . 0 . - 262: 0 .. _234 _ -..-. 0 _ 418 F _ -. 22A-tph__.___ _. _., _ 1.358 _. 38.02 0.00 1780 155 5910 0 __.-_262 3.2 _-__1217 0 6 c)AED excursion 206 217 Enw1ope loss/gain 15909 10138 3158 2076 12 a) Infiltration 3347 944 720 203 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 7250 800 Subtotal (lines 6 to 13) 19256 18332 3878 3079 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 153 64 14 Subtotal 19256 18332 4031 3143 15 Duct loads 29% 44% 5651 8093 29% 44°/ 1183 1388 Total mom load 1 24907 1 26425 5215 4531 Air required(cfm) 1167 1167 244 200 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- -4 wrlgtirso_R- 2019-Apr-2912:36:26 P. Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 ...ADAMS HOMES- 1780 B MODEL-SAN BENDETTO 5321.mp Calc = MJ8 Front Door faces: SE wrightsofY Right-M Worksheet Job: 1780 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: DUICKCALCS@AOL.COM 1 Room name O LINEN O BATH 2 5yosed wall 5.0 ft 18.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 4.0 It 20.0 W 1.0 x 113.0 fl 113.0 W -Ty Construction U-value Or HTM Area (01 Load Area (ft.) Load number (Btuh/ft''F) (Btuwftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V11-- � T�_ 13A-0ocs 2 glazing. clrlowa_ 13A-0ocs 0.143 _ _ 0.650 0. rle ne a 4.00 __18.20 4.20 . _ 2_19 ._. 26.88 2. _..__ _.. 0 _ _.. _ _ 0 0 0 ._�0 0 __.. _0 _ . 0 0 _.. _ _ 0 _ _0 0 ._..� ___... 0.._ 0 s. __ .� _0 0 ..___._.2$6 _._.__.0 0 140 _.. _0 0 _. W, F--G IIIL------DDDDDD W, 2glazing, clr laws 18P.-4acs 2 glazing, clr lave 11D0__._.. 13A-0gcs _ __0.650650 0.143 0.650 .0.390 0.143 _e se as se_ s __ 1.20 4.00 18.20 __ 10.92 4.00 _ 32.42 2.1919 21.07 __ 10.34 2.19 __-0 0__. . 0 __ ._ __0.__ 0 0 --0 0 ----- 0. 0 0 --0 0 .____0 0 0 __ _ 0_-___0 0 _ _._0 0 0 0 _ __0 0 0 .0 0 0 0 0 . _._ _0 0 _ _ 0. 0 0 ____..0 0 ---------0 0 _�_ _G_ T 2 glazing, clr low-e -_ 13A-0dcs - 0.650 0.143 .-s_ sw 18.20 4.00 _ 14.99 2.19 _ 0 0 - _ ___0 - 0 - .0 0 _ 0 _.. .0 _ _- _ 0 0 _ _ 0 _ _ 0 0 _. _ _ 0 0 __ _� -r Yt/ 2 g1ming,.clr lmw 13A-0acs 2 glazing, clr low-e ___0.650 0.143 0.650 sw_ nw nw _ 18.20_._..21.07 4.00 18.20 2.19 26.88 _.. ___0 40 0 ___0 40 0 _____.._0 160 0 _..-__0 88 0 .___-0 80 0 .. _0_. 80 0 __ 0 320 0 175 0 I'G C -_ . 2 glazing, clr low-e 16B30ad_._ -. _ _ 0.650 _ . _0.032 nw = _ 18.20 _ 0.90 26.88 1.60 0 .. - 20 ___ _ 0 __ _ 0 _. 78 _ 0 32 _ 0 _ 113 0 113 _ _ 0 _ 0 F _ 22A-ipr� ... . _ _ _ .1.358 _. _ 38.02 0.00 20 _20 5 ... _. 190 _ _ 10 _ _ _ _ 113 _ _ _ _ _- 18 _ _101: 68-4 ..181 _ _ -0 6 c)AED=ursion -3 -13 Enwlope loss/gain 368 116 1362 483 12 a) Infiltration 90 25 324 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6to 13) 458 142 1686 575 Less wdemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 _458 0 0 _142 0 0 317 2004 0 98 673 15 Duct loads 1 29% 449/6 0 0 29% 44% 588 297 Total room load Air required(cfm) 0 0 0 0 2592 121 970 43 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r'}� wrrghtso£t- 2019-Apr.2912:36:26 p RlghtSuite@ Universal 2018 18.0.31 RSU08101 Page 2 ...ADAMS HOMES 1780 B MODELSAN BENDETTO 5321.rup Calc = MJ8 Front Door faces: SE wrightsoft• Right-J® Worksheet Job: 1780 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name O WIC BEDROOM 2 2 Exposed wall 6.0 it 10.0 it 3 Room height 8.0 0 heat/cool 10.0 ft heat cool 4 5 Room dimensions Room area 1.0 x 70.0 ft 70.0 ft2 1.0 x 149.5 ft 149.5 ft2 Ty Construction U-value Or HTM Area (ft2) Lead Area (112) Load number (Btuhlft2-'F) (Btulvft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P(S Heat Cool 6 Y Ll2 13A-4ocs 0.143 he 4.00 2.19 48 ._ -48 192 105 --- - 0 _ 0 -- - -0 - -0 2 glazing, clrloec _ 13A-4ocs _ _ _. 0.650 0.143 n e. a 18.20 4.00 _ _ 26.88 2.19 _ - 0 0 . 0 0 - . _ 0 0 _ 0 0 . _ _ 0 0 . 0 0 _ _ _ _0 0 _ _ _0 0 t-G 11 - 2 glazinq, clr low-e 13A-0acs _0.650 0.143 _ e se _ _ 18.20 4.00 _ 32.42 2.19 0 ._ ._ 0 0 _ _.-0 0 _ .0 0 _ ._0 0 _0 0 ._ 0 0 .._ ..0 0 _. .0 2 glazing, clr Iowa 11D0- _ _- -_.. 13A�1ocs 0.650 ..._ 0.390 0.143 se se_ s 18.20 - 10.92 4.00 21.07 ._ 10.34 2.19 0 _0 0 0 _ .. 0.... 0 0 .0 0 0 ._.._0 0 0 0 0 0 __.__0: 0 0 _ -0. 0 0 _ _-0 0 W, T-G IN 2 glazina. clr_ low-e 13A-0dcs _ _ 0.650 0.143 s sw _ 18.20 4.00 14.99 Z19 0 _ .0 _ _ _ 0 _ _ - 0 _ . 0 _ .100 _ _ .� 85 _ .340 . - 186 �--G 2 glazing, clr Iowa _ 13A-4ocs 2 glazing, clr Iowa _ _0.650 0.143 0.650 sw nw rw - 18.20 4.00 18.20 _. 21.07 Z19 26.88 ..0 0 0 . - -0 0 0 -_ _.0 0 0 _. _ 0 0 0 _15 0 0 _. 7 0 0 .. 273 0 0 _316 0 0 C 2 nlazinq, clr low-e 16B30ad - _ 0.650 `0.032 nw - _ _ 18.20 0.90 26.88 '1.60 0 . - -70 0 _. 70 0 _ 63 _ 0 112 0 -- - 150 _ 0 150 0 134 0 239 F 22A-tph - - . 1.358 - 38.02 0.00 _ --70 _ 6 _ 228 0 _ 150 - - 10 380 - _ 0 6 c)AED excursion S 131 Envelope loss/gain 483 212 1128 873 12 a) Infiltration 108 30 225 63 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6to 13) 591 242 1353 1436 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 9 204 93 14 Subtotal 596 251 1557 1529 15 Duct loads 29% 44% 175 111 29% 44% 457 675 Total room load Air required (cfm) 771 36 362 16 2014 94 2204 97 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -rl&- wri9rifsoTY- 2019-Apr-2912:36:26 /euA RightSuite® Universal 2018 18.0.31 RSU08101 Page 3 ...ADAMS HOMES. 1780 B MODELSAN BENDETTO 5321.mp Calc = MJ8 Front Door faces: SE wrightsoft• Right-JO Worksheet Job: 1780 MODEL Entire House Date: Apr29,2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name CLST 2 CLST 3 2 Exposed wall 3.0 If 20 If 3 Room height 8.0 it heat/cool 8.0 it hest/coe 4 5 Room dimensions Room area 6.0 x 3.0 ft 18.0 fit' 6.0 x 2.0 If 12.0 VP Ty Construction U-value Or HTM Area (ft2) Load Area (fP) Load number (Btuh/fl? °F) (Btuh/f8) or perimeter (ft) (Btuh) or Perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 yJ LG 13A4ocs _ .. ...... 2 glazing, clr love _ 13A4ocs _. _ 0.143 _ 0.650 0.143 i1e ,re, a � 4.00 - 18.20 4.00 2.19 26.88 2.19 � 0 _ 0 -0 . � 0 0 0 0 _ .__ 0 0 _ ... _� _ 0. 0 _.. _ _ 0 _0 0 _ - 0 _ 0 0 _ .0 _ _ _0 0 . 0 _ 0 0 W 11 L-G % � 2 glazinc. clr Iowa 13A4ocs _ 0.650 _ 0.143 e as _ 18.20 4.00 32.42 2.19 0 �_ ..0 0 0 0 _ _ _ 0 0 _ 0 0 _ ....-_0 0 _ . _0 0 _ _. .0 0 _ 0 � (D L- . ___ . W 2 glazing, ilr Iowa 11D0. _. 13A4ocs 0.650 _ 0.390 0.143 se se_ s 18.20 _ 10.92 4.00 21.07 _ .10.34. 2.19 0 _ _ 0 0 0 - ..0 0 0 - __.. 0... 0 0 _ 0 0 0 .___0 0 0 ._. 0 0 0 _ ..0 0 0 _ 0 0 Y-C Y+1- 2 glazing, clr low-e 1344acs - - 0.650 � 0.143 s sw 18.20 4.00 14.99 2.19 0 24 0 24 0 -� 96 _ _ 0 - 53 _ 0 16 0 16 _ 0 61 _ 0 35 -G 2 glazing, dr.low-e _ 13A-4ocs 2 glazing, clr love _ _ 0.650 0.143 0.650 sw w nw - 18.20 4.00 18.20 21.07 219 26.88 _ _ . 0 0 0 0 0 0 _ _ 0 0 0 . . --0 0 0 _ _ .0 0 0 -0 0 0 . .- _. 0 0 0 _ 0 0 0 L�-CC C - 2 glazing, clr low-e 16B30ad - 0.650 -_ -0.032 nw - _ 18.20 _ 0.90 26.88 1.60 _ 0 18 _ _ 0 _ 18 0 - 16 . 0 29 0 _ -_-12 _ _ 0 '12 0 ii _ 0 19 F _. 22A-tph_„. - _ - - . 1.358 _= 38.02 _ 0.00 - .. 18 3 - ----114 _ _._ 0 - 12 - 2 _ 76 _ _ 0 6 c)AED excursion _2 _1 Enw1ope loss/gain 226 79 151 53 12 a) Infiltration 54 15 36 10 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 280 94 187 63 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 -280 0 0 -94 0 0 -187 0 0 -63 0 15 Duct loads 1 29% 44% 0 0 29% 449/6 0 0 Total mom load Air required (cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pk- wrl9htsoPt- 2019-Apr-2912:36:26 A RightSuite® Universal 2018 18.0.31 RSU08101 Page 4 ...ADAMS HOMES- 1780 B MODELSAN BENDETrO 5321.rup Caic = M38 Front Door faces: SE +� wrightsoft• Right-JO Worksheet Job: 1780 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name BATH 2 BEDROOM 3 2 E)q)osed wall 0 ft 10.0 If 3 Room height 8.0 0 heat/cool 10.0 ft heat/ccol 4 5 Room dimensions Room area - 9.0 x 5.0 It 45.0 fit' 1.0 x 136.0 0 136.0 ft' Ty Construction U-value Or HrM Area (ft') Load Area (ft') Load number (BtuNWF) (Btut✓R') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Coal 6 y!- -- LC 13A46cs _.. _ __ - 0.143 . ne _ 4.00 _ .. _ 2.19 -_.._ _ ..0 .. _ .0 .... _., 0 _ . u _0 _ ..0 _.._ _ o .p _._. 0 2glazing_cirlow_e -.. 13A-4ocs _.._ 0.650 0.143 .re a - _18.20 4.00 ___. 26.88 2.19 _ _ _ 0 0 . 0 0 _ ---0 0 -0 0 _ _ _. 0 0 . _ _ -0 0 ._. 0 0 .0 0 WI 11 � Li. `N 2 clazina, c(r lower _, 13A-0ocs _ , _ 0.650 0.143 _ e - se -__ 18.20 400- _ 32.42 2.19 0 _ ._0. 0 0 0 __0 .__.__0. .0 0 0__. 0 ___0 0 __. -.0 0 >.��. 0 �C 2 glazing. clr Iowa 1ID0. ----__ _ 0.650 -__0.390 se se.. 18.20 ___1092 21.07 ___10.34 0 _. ._0 0 0. 0 .__ 0 0 _ ._0. 0 ._0 0 _. _ 0 0 _._ 0 0 0 V+/ 13A-4ocs 0.143 s 4.00 219 0 0 0 0 0 0 0 0 _,_ VN 2 glazim. clr lowe_,. 13A-0ocs _.,,-0.650 0.143 _s sw _18.20 4.00 _ 14.99 2.19 -_ 0 0 0 - ' 0 0 --- 0 0 - -� 0 _. 0 100 0 --- - 85 _ 0_ 340 0 186 �_G' T 2 glazing, clr.low-e 13A-00cs 2 glazing, clr low-e _ . 0.650 0.143 0.650 sw. nw my -18.20 4.00 18.20 . _21.07 219 26.88 .. - 0 0 0 _ __ _0 0 0 _ ..__0 0 0 . _ -0 0 0 _ _ .15 0 0 ___ 7 0 0 .. 273 0 0 __ _. 316 0 0 _ C.. __ 2 glazipp, cIr low_e -_ 16B30ad._. _ _ _- __0.650 _ 0.032 my __ _ 18.20 -0.90 - 26.86 _ 1.60 - _ _ 0 45 _ 0 _45 __- 0 ._ _ 40 -, - _ 0 _ _._72 __ 0 __ _ 136 0 _ ---136 _ _ 0 .122 0 __218 F-_ R 22A-tph____. __. ._ _ 1.353 _µ _ _ 38.02 .... 0.00 , 45 - _- 0 _ _ ,. 0 0 ... 136 _ _ 10 _ . „380 _ ,__.. 0 6 c)AED excursion -2 132 Emelope loss/gain 40 70 1115 851 12 a) Infiltration 0 0 225 63 b) Room Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal(lines 6to 13) 40 70 1341 1415 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 151 66 147 59 14 Subtotal 191 136 1487 1473 15 Duct loads 29% 44% 56 60 29% 44% 436 650 Total room loaf 247 197 1924 2124 Air required (cfm) 12 9 90 94 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. y}t wri9�+>�oiY- 2019-Apr.2912:36:26 A&A RlghtSuite® Universal 2018 18.0.31 RSU08101 Page 5 ...ADAMS HOMES- 1780 B MODELSAN BENDETTO 5321.rup Cale = MJ8 Front Door faces: SE wrightsoft' Right-M Worksheet Job: 1780 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY HALLWAY 2 Exposed wall 0 It 0 ft 3 Room height 10.0 ft heat/cool 10.0 It heat/cool 4 Room dmenslons 7.0 x 7.0 It 1.0 x 84.0 ft 5 Room area 49.0 ft' 84.0 ft2 Ty Construction U-value Or HTM Area (w) Load Area (ft') Load number (Btuh/$'--°F) (Btut ft2) or perimeter (0) (Btuh) or perimeter (f) (9tuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _..- -G, 13A46cs _ 0543 ne 4.00 � 2.19 - _ - _ 0 _ 0 �0 ., - 0 .. 0 .. .. -0 _- .0 . .0 -. ._ b 2glazing, clr.low-e _ 0.650 ne 18.20 . 26.88 _0 _ - 0 _ - _._ _0 _ 0 _ . _0 0. _ 0 _ _ 0 W, 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 �G 2 glazinq, clr lcw-e 0.650 a 18.20 32.42 0 0 0 11 '�1 13A-4ms � - - -0.143 se 4.00 _ 2.19 _ _0 0 _ _0 0 _ _ - 0 0 _ _ _0 0 _ 0 _ _0 0 -0 0 F--G �D 2 glazing, clr low-e 0.650 se 18.20 21.07 0 0 0 0 0 0 0 0 1100.---- ---- _0.390 se _ 10.92_ 10.34 ._0 _..0. .._0 .____.0 _._._0. - 0. _-.0._ 0 V+/ 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 _ --_C_ 2 olazin, clr low-,_ 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 t13A-4ocs __ 0.143 _ sw __ 4.00 _ 2.19 --- 0- _ - 0 _-_ 0 _ 0 - . 0 0 _ 0 0 -G 2 glazing, ch low-e- _ _ (LM . sw_ 18.20 21.07 _ 0 - -0 - ._ -0 _ _ _ 0 0 _ 0 0 _ .. 0 l�/ F�-CC' 13A flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr lowe 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 _ 2 glazinq, clr low_e 0.650 nw 18.29 26.88 0 0 0_ 0 0 0 0 0 C 1613-30ad .. _ _ 0.032 - 0.90 _ 1'60 49 _ '_ 49 _- 44 - 78 84 84 75 134 F 22A-toh 1.358 38.02 0.00 49 0 0 0 84 0 0 0 6 c)AFJJ munsion -18 -3 Envelope loss/gain 44 61 75 131 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 750 0 Subtotal (Imes 6 to 13) 44 811 75 131 Less exlemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 13 23 -75 -131 14 Subtotal 57 833 0 0 151 uct loads 29% 44% 17 368 29% 44% 0 0 Total room load 73 1 1201 0 0 Air required (cfm) 3 53 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AS-pp- wr;�9!+troR- 2019-Apr-2912:36:26 , RightSuite® Universal 2018 18.0.31 RSU08101 Page 6 ...ADAMS HOMES- 1780 3 MODEL-SAN BENDETTO 5321.rup Calc = MJ8 Front Door faces: SE wrightsoft Right-J® Worksheet Job: 1789 MODEL B Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name AHU CLST STORAGE 2 Emposed wall 0 It 0 ft 3 Room height 8.0 ft heaUccol 8.0 ft heat/cool 4 5 Room dimensions Room area 3.0 x 4.0 It 12.0 fix 3.0 x 8.0 it 24.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft2j Load number (Btulllft2-°F) (BtuMft.) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Caol Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 WI 13A406s 291azing, cIrlow-e ._. 13A4ocs 0.143 .- 0.650 0.143 .ne. ne. a ..- 4.00 -._ 18.20 4.00 .__,2.19 -26.88 2.19 ._ .---- ,0 _ .-_ ._0._ 0 .._ ...0 _ _ _0 0 _. _ 0 _0 0 _ _0 _ _0 0 0 . 0 0 _- ... _0.__. ._ -0 0 ._0 _-.._ __0 0 _. ___0 _ .._ .0 0 ---G- 2 glazing, clr low-e.� ___ 0.650 e,-._ 18.20. _ 32.42 ____0 ____ ,._0 _ _ .0 _ 0 _. _0 _ 0 ------------ 0 2 glazing, clr low-e 11D0__.-- _ _ .._ 13A40cs 0.650 ._- _0.390 0.143 se se, s 18.20 _.. 10.92 4.00 21.07 _ 10.34 2.19 0 - _- 0.. 0 0 __0 0 0 ___._ _ 0. 0 0 __-! .0._. 0 0 _ __ 0 0 0 ._ _0 0 0 _ ._0 0 .0 __.0 0 _�- - w� 2 glazino. clr low-e 13A4ocs - 0.650 . - 0.143 s "sw 18.20 a.00 14.99 `--21s -._ _ 0 o'--_- 0 o 0 ----o --`-o -'o -- -'o 0 ---- li 0 ' o .__.. V)! 2 glazing, clr low-e. _ 13A4ocs 2 glazing, clr low-e _ _0.650 0.143 0.650 sw. nw my _ 18.20 4.00 18.20 - _21.07 219 26.88 _ -0- 0 0 ___ 0 0 0 _ _ __0 0 0 _ ._--0 0 0 .._. .0 0 0 _ _ _ _ _0 0 0 _- __ 0 0 0 _ .0 0 0 . C ... 2 glazinq, clr Iowa_ 160.v'Oad.. .. _ _ 0.650 _ _ A.032 my .. -- _18.20 � 0.90 _ _26.88 � 1.60 _ 0 _ _72 0 =_ �.:. ,12 _ _ 0 � .. 11 0 . 19 0 ' _24 _ 0 ...24 . _ 0 _ . 22 0 _ . _ 38 F- _. 22A-tCh _. _ _ 1.358 __. _. °�8.02 0.00 _ 12 _ .. _ _ 0 0 _ 0 _. 24 .. _. _0 0 _ ,0 6 c)AED excursion 0 -1 Emelope loss/gain 11 19 22 38 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliaaces/alher 0 0 Subtotal (lines 6 to 13) 11 19 22 38 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -11 -19 -22 -38 14 Subtotal 0 0 0 0 15 Duct loads 29% 44% 0 0 29% 44% 0 0 Total mom load 0 0 0 0 Air required (cfm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -I - w-rr9F+TsoH- 2019-Apr-2912:36:26 A -' RightSuile® Universal 201818.0.31 RSU08101 Page 7 ...ADAMS HOMES- 1780 B MODELSAN BENDETrO5321.wp Calc = MJ8 Front Docr laces: SE wrightsoft' Right-M Worksheet Job: 1780 MODEL B v Entire House Date: Apr29,2O18 QUICK CALCS, INC. By. 317 ST LUCM LANE, FORT PIERCE. FL 34946 Phone: 772-466-6799 Fax: 772-466.6796 Email: OUICKCALCS@AOL.COM 1 Room name FAMILY KITCHEN 2 Exposed wall 26.0 It 12.0 If 3 Room height 10.0 It heat/cool 10.0 It heat/cool 4 5 Room dimensions Room area 18.0 x 19.0 ft 342.0 ft2 15.0 x 120 It 180.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (B%Wft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (f) (Btuh) Heat I Cool Gross WP/S Heat Cecil Gross N/P/S Heat Coal 6 4)1 - - 13A-4o6s _ _ ... ..0.143 �ne �� 4.00 � 219 . _ ._1� . _. _.1� _ _ �1 __.,.-350 � 120 _.. __ 120 -�. __� - LCa Vj/ 291azing, cirlcwce _- 13A-0a'a 0.650 0.143 re. a 18.20 4.00 _26.68 2.19 ------ _ 30 0 _ 0 0 . 546 0 ._ . 806 -0 - 0 0 ._. ._ 0 0 ._.. 0 0 ._ . __0 0 11 _�_-_-_G 4)/ - 2 glazinq. clr lower._._ 13A-0gds _ ._0.650 0.143 e_ se _ 18.2) 4.00 �32.42 219 -.0 0 _ _ 0 0 0 0 0 ` �� -- -0 -� -0 0 0 -- � -0 0 --' VO 0 � -0 2 glazing, clr lave 11D0. 0.650 _._.0.390 se se- 18.20 _..1O.92___10.34 21.07 0 .'__0 0 0 0 0 0 ____0 0 0 _0 V)/ s 0.650 s 2.99 _ 0 ___.___0 0 __0 0 ___._0 0 ----- _-0 0 _._ 0 ----- _0 0 ___ 0 . .__ U+/ 2 olaan 13A-4 q. clr lowe 13A-0ads - 0.650 _ _.-0:143 s sw 8.20 14.00 4.00 _12.19 - 219 0 �._ ._...0 0 _ ..0 0 _ ._.__.0 0 ___.. O 0 _ _ _0 0 ._____.0 0 _ _ .-._0 0 .._ 2 glazing, clr lower _ . .--0.650-sw_ .. 18.20-_21.07 ._ .-_0 ------ .0. _ .0 ___._.0 - _0 __ _ _-0 _ _ 0 __ _.0 Ytl �L---(C' 13A-4ccs 2 glazing, clr law-e 0.143 0.650 nw nw 4.00 18.20 2.19 26.88 70 0 52 0 209 0 114 0 0 0 0 0 0 0 0 0 _ C _ F 2glazinq. clr low_e. 16B3Oad_ _ _ 22A-toh -- 0.650 -0.032 1.358 mv_ . c - ___18.20. _ 0.90 38.02 26.88 _ _ 1.60 0.00 _ 18 __ 342 342 , _ _ 0 _ _ _ _ 342 26 ,. 325 . _ 306 989 480 . _ _ 647 0 -_ „ 0 - _ 180 180 _ 0 . _ _ _180 12 _ _ 0 _ _ ..J61 456 .,. _. 0 _ . 288 0 6 c)AED emurslon -107 39 Envelope loss/gain 3016 2191 1098 511 12 a) Infiltration 585 165 270 76 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants gQ 230 0 0 0 0 Appliances/other 2500 1200 Subtotal (lines 6 to 13) 3601 4856 1368 1787 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 39 68 0 0 14 Subtotal 3640 4924 1368 1787 15 Duct loads 1 29% 440/6 1068 2174 29% 44% 402 789 Total room load 1 4708 7098 1770 2576 Air required (cfm) 221 313 83 114 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -1'}H wrigheso�T--t- 2019-Apr-2912:36:26 Right -Suite@ Uniwrsal 2018 18.0.31 RSU08101 Page 8 ...ADAMS HOMES- 178D B MODELSAN BENDETT05321.mp Calc = MJ8 Front Door faces: SE wrightsoft• Right-M Worksheet Job: 1780 MODEL Entire House Date: Apr29,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 7724666796 Ema l: OUICKCALCS@AOLCOM 1 Room name FOYER DINING 2 Bglosed wall 5.0 It 26.4 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dmensions Room area 5.0 x 21.0 It 105.0 fP 1.0 x 159.0 It 159.0 fN Ty Construction U-value Or HTM Area (ftq Load Area p) Load number (BtuhrffW) (BtufJft� or perimeter (ft) (Btuh) or pedmeter (ft) (Btuh) Heat r Cool Grass N/P/S Heat Cool Gross N/P/S Heat Cool I--fi 2glazing, clr.low-e __ 13A4ccs 0:143 _. .. 0.650 0.143 ne ne a - 4.0u __ 18.20 4.00 2.19 _. 26.88 2.19 .... ---0 _ _ 0 0 0 0 0 ._ __O _. 0 0 0 _ _. --0 0 _. _-� a_ _ 15 42 _. _ 75 .._ _ _0 32 -. _300 . _..273 130 - _164 403 71 __._. Nil 11 ' 2 glazinq, clr low-, 13A-4ccs _ _ 0.650 _ _ _0.143 e- se 18.20 4.00 _-32.42 2.19 -_-.0 -50 0 - - _-.30 0 . __ 120 0 .__. _ 65 10 90 1 - - -. -70 _ __ 182 �280 __ 324 153 2 glazing, clr low-e 11D0_.-._ 13AAocs 0.650 _. _.0.390 0.143 se _se. s 18.20 _.. 10.92 4.00 21.07 _ 10.34 2.19 0 _ _ .20 0 0 __. _ 20 0 0 219 0 0 __- 208 0 20 ------ -0 42 10 _ _ .._ 0 32 364 _._____0. 130 421 - .0 71 ._.._ IN _, _ G 2 glazinq _ch- low-e_, -.---0.650 -sw 4.00 2.19 - 0 0 0 0 0 -0 '- --- 0 - ' 0 UIJ 2 glazing, clr Iowa, 2 glazing, clr lower 2 g1wi g, _ _ 0.650 0.650 0.650 . sw nw my _ 18.20 4.60 18.20 _ 21.07 26.88 6.88 _ 0 0 0 .- _ _ .0 0-� 0 0 0 0 - - _ - 0 0 0 ------ 0 0 0 _ . _ .A- 0 0 _ 0 0 0 _ .. 0 0 0 L�GC - C- _- 2 glazinq, clr low-e_ _ 16630ad__� _ .._ _ - _ 0.650 _ 0.032 my _� -. 18.20 _... 0.90 _ 26.88 .._ 1.60 _ 0 _ . 105 - _ 0 _ _ '105 0 .- 94 _ 0 ., _ 168 _ 0 �-' -159 0 ;' �159 _ . _ _ 0 142 0 .254 F - _ 22A4oh_- .- - 1.358 -__ _ 38.02 _ 0.00 105 - 5 _ _ _190 - ,.._ 0 -_ _ 159 -__ 26 - 1004 _. 0 6 c)ASO excursion -32 -47 Envelope loss/gain 623 409 2988 1965 12 a) Infiltration 113 32 596 168 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 0 Subtotal(Imos; 6to 13) 736 1441 3584 2133 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 4 8 0 0 14 Subtatal 740 1449 3584 21W 15 Duct loads 29% 44% 217 640 29% 44% 1052 942 Total mom load Air required (cfm) 958 45 2088 92 4636 217 3075 136 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrrgrilgo,TS- 2019-Apr-2912:36:26 �A - RlghtSuite® Universal 201818.0.31 RSU08101 Page 9 ...ADAMS HOMES- 1780 B MODELSAN BENDET70 5321.rup Calc = MJ8 Front Door faces: SE - wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For. ADAMS HOMES 5321 SAN BENDETTO PLACE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1167 cfm Job: 1780 MODEL B Date: Apr29,2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1167 cfm 169 ft I Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 247 12 9 1.000 4.0 Ox0 VIFx 10.3 115.0 st2 BEDROOM c 2204 94 97 1.000 7.0 Ox0 VIFx 11.3 115.0 st1 BEDROOM 3 c 2124 90 94 1.000 7.0 0x0 VIFx 14.3 115.0 st2 DINING h 4636 217 136 1.000 7.0 Ox0 VIFx 33.9 135.0 st4 FAMILY c 3549 110 157 1.000 8.0 Ox0 VIFx 11.1 115.0 st2 FAMILY -A c 3549 110 157 1.000 8.0 Ox0 VIFx 12.0 115.0 SH FOYER c 2088 45 92 1.000 7.0 Ox0 VIFx 26.6 135.0 st4 KITCHEN c 2576 83 114 1.000 7.0 Ox0 VIFx 25.9 135.0 st4 LAUNDRY c 1201 3 53 1.000 6.0 OX0 VIFx 9.8 115.0 st2 O BATH h 2592 121 43 1.000 6.0 Ox0 VIFx 18.4 135.0 St3 OWIC h . 771 36 16 1.000 5.0 Ox0 VIFx 19.3 135.0 SO OWNERS BEDROOM h 2607 122 100 1.000 7.0 Ox0 VIFx 21.2 115.0 Sit OWNERS BEDROOM -A h 2607 122 100 1.000 7.0 Ox0 VIFx 14.2 115.0 SH Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 158 59 1.000 802 6.0 0 x 0 VinlFlx SO SO Peak AVF 607 513 1.000 772 12.0 0 x 0 VinlFlx st4 Peak AVF 345 342 1.000 633 10.0 0 x 0 VinlFlx st2 st2 PeakAVF 560 654 1.000 833 12.0 0 x 0 VinlFlx 'Or�- wrightsoft- 2019-Apr-2912:36:28 MCA •"••�.••••-••-�.-+ RightSuite® UnNersal 201818.0.31 RSU08101 Page 1 ...ADAMS HOMES- 1780 B MODEL-SAN BENDET(O 5321.rup Calc = MJ8 Front Door faces: BE Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rbl Ox0 1167 1167 0 0 0 0 Ox 0 VIFx W rightsOR' 2019-Apr-29 12:36:28 p �W�.•r .�—.-+ Right -Suite® Uniwrsal 201818.0.31 RSU08101 Page 2 ...ADAMS HOMES- 1780 B MODELSAN BENDETfO 5327.rup Catc = MJB Front Doer faces: SE This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.