HomeMy WebLinkAboutTRUSS PAPERWORKNumber:
Lot Number:
Address:
l'russ Fabricator: East Coast Truss
.ipb Reference: #2244344 - MEL-RY - MORADI
Tampa, FL 33610
(913) 972-1135
22443-22444 06/02/2011
Engineering Index Sheet
61
A Professional Engineer's Seal affixed to this Index Sheet Indicates the acceptance of professional Engineering
responsibilities for Individual truss components fabricated in accordance with the listed and attached Time; Specification
Sheets. Determination as to the suitability of these Individual truss components for any strecture is the responsibllty of the
Building Designer, as defined in ANSNTPI 1.95, Section 2.2. Permanent files of the original Truss Specification Sheet are
maintained by East Coast Truss. Questions regarding this Index Sheet and/or the attached Specification Sheets may be
Date Mark
Data Mark
PLjit i..jA—
Date
Standard Loading:
T.C. Live
20 psf
T.C. Dead
15 pa£
H.C. Live
0 Paid!
B.C. Dead
5 ps£
Total
40 pa£
ANSI I ASCE 7-D5
Main Wind Force Res. Sys.
Wind Speed: 140
-Mean Roof HL: 20
Exposure Category: C
Occupancy Factor: 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load: 15.0
BC Dead Load : 6.0
Mark Notes:Referto Individual truss design drawings
for special loading conditions.
SUANNE®
BY
13t: LucieCunty
l� }
i�t 1r1 to �$y 1� tt1x'f' 1,j
J; � VAC EX8 • :V
Online Plus'• 0 Copyright MITekO 1996-2011 Version 28.0.006 Job Index Sheet 6=011 10.30:20 AM
• �j•p
IL
`* J
#22443-44 - MEL-RY - MORADI
Page: 1
22443-22444/
1
2
SP
A01G 3.20
29-07-11
00-00
00-00
4/4
22443-22444/
1—
_1
SP
- A02 3-.18
29-10-13
00-00
00-00
4/4
22443-22444/
1
1
SP
A03 3.18
30-01-12
00-00
00-00
4/4�
22443-22444/
1
1
SP
A04 3.18
30-04-11
00-00
00-00
4/4 �-
22443-22444/
1
1
SP
A05 3.18
30-07-09
00-00
00-00
4/4
22443-22444/
1
1
SP
A06 3.20
30-09-14
00-00
00-00
4/4
22443-22444/
1
1
SP
A7 3.20
30-09-14
00-00
00-00
4/4
22443-22444/
1
1
CAT5
A8 3.20
30-09-14
00-00
00-00
4/4 - �>
22443-22444/
1
1
SP
A9 3.20
30-09-14
00-00
00-00
4/4
22443-22444/
1
1
SP
A10 3.20
30-09-14
00-00
00-00
4/4
22443-22444/
1
1
SP
All 3.20
30-09-15
00-00
00-00
4/4
22443-22444/
1
1
SP
Al2 3.20
30-09-15
00-00
00-00
4/4 —
22443-22444/
1
2
SP
A13 3.20
30-02-08
00-00
00-00
4/4-
22443-22444/
1
2
SP
A14 2.95
29-00-13
00-00
00-00
4/4 —
22443-22444/
1
1
SP
A15 2.95
23-06-00
00-00
00-00
4/4 —
22443-22444/
1
2
SP
A16G 2.95
11-07-15
00-00
00-00
4/4
22443-22444/
'
2
1
ENDJ
-CJ1 3.20
01-00-00
00-00
00-00
4/4
)vl(ve PlmT"O Copyright Miiek®I996-20I1 Vealov 3g.0.0065vmmery Pege llussu Report D.t.06/OMI P.9.1
#22443-44 - MEL-RY - MORADI
Page: 2
22443-22444/
• 2
1
MON4
-CJ3 3.20
03-00-00
00-00
00-00
4/4 /
22443-22444/
-2-1
MON4-
- -CJ5 3.20
05-00-00
00-00
00-00
4/4 �
22443-22444/
1
1
MONO
-CJ7 3.10
07-02-15
00-00
00-00
4/4 �
/
j
22443-22444/
/
1
1
MON4
-CJA 3.20
06-11-02
00-00
00-00
4/4 —
22443722444/
1
1
MON4
-CJB 3.20
05-09-14
00-00
00-00
4/4 �
/
22443-22444/
1
1
MONO
-CJC 3.20
04-08-10
00-00
00-00
4/4 �
/
22443-22444/
1
1
MONO
-CJD 2.85
04-04-06
00-00
00-00
4/4 �
22443-22444/
2
1
MONO
-CJE 3.20
03-00-00
00-00
00-00
4/4 /
22443-22449/
1
1
ENDJ
-CJF 3.20
03-00-04
00-00
00-00
4/4 /
22443-22444/
/
1
1
ENDJ
-CJG 3.20
02-02-01
00-00
00-00
4/4
22443-22444/
7
1
MONO
-EJ7 3.20
07-00-00
00-00
00-00
4/4 /
22443-22444/
1
1
ENDJ
-EJ28 2.95
02-08-09
00-00
00-00
'
4/4
22443-22444/
1
1
ENDJ
-EJ36 2.95
03-06-11
00-00
00-00
4/4
22443-22444/
1
1
ENDJ
-EJ44 2.95
04-04-14
00-00
00-00
4/4
22443-22444/
1
1
ENDJ
-EJ52 2.95
05-03-01
00-00
00-00
4/4
22443-22444/
1
1
SP
-EJ511 2.95
05-11-06
01-14
00-00
4/4
22443-22444/
1
1
MON4
-HJ7 2.27
09-10-13
00-00
00-00
4/4
Online Hum 0 Copyright MTe1S 1996-2011 Version 28.0.006 Sommer, Page Treun Report Date(101111 Pnge:2
#22443-44 - MEL-RY - MORADI
Page: 3
22443-22444/
1
2
FLAT
FG1 0.00
08-07-15
00-00
00-00
4/4
22443-22444/
---1 -2-
FLAT
FG2 0.00
05-00-07
00-00
00-00
4/4
22443-22444/
1
1
SP
FT23 0.00
10-11-11
00-00
00-00
4/4
I
22443-22444/
1
1
SP
FT24 .0.00
10-11-15
00-00
00-00
4/4
22443-22444/
1
1
SP
FT25 0.00
11-00-02
00-00
00-00
4/4
22443-22444/
1
1
SP
FT26 0.00
11-03-00
00-00
00-00
4/4
22443-22444/
1
1
SP
FT27GE 0.00
11-03-00
00-00
00-00
4/4
22443-22444/
2
1
M100
FL3 0.00
11-11-08
00-00
00-00
2/2
22443-22444/
7
1
M100
FL4 0.00
13-00-00
00-00
00-00
2/2
22443-22444/
3
1
M100
FL5 0.00
13-03-08
00-00
00-00
2/2
22443-22444/
3
1
M100
FL6 0.00
07-10-08
00-00
00-00
2/2
22443FL�9440.00
\\
1
1
M100
04-04-09
00-00
00-00
2/2
U \I
22443-22444/
1
1
M100
FLB 0.00
09-09-14
00-00
00-00
2/2
22443-22444/
1
1
M100
FL9 0.00
13-05-06
00-00
00-00
2/2
22443-22444/
1
1
M100
FL10 0.00
13-00-09
00-00
00-00
2/2
22443-22444/
1
1
M100
FL11 0.00
13-03-08
00-00
00-00
2/2
22443-22444/
1
1
M100
FL12 0.00
13-06-07
00-00
00-00
2/2
Online Nairn 0 Copyright MTek®199&2011 Version 28.0.006 Summary Page Truman Report Date06102/11 Page:]
#22443-44 - MEL-RY - MORADI
Page: 4
22443-22444/
1
1
M100
FL13 0.00
10-05-14
00-00
00-00
22443-22444/
- --I—I
M100
- FL14 0.00
10-08-12
00-00
00-00
22443-22444/
3
1
M100
FL15 0.00
10-11-07
00-00
00-00
22443-22444/
2
1
M100
FL16 0.00
14-02-15
00-00
00-00
22443-22444/
1
1
M100
FL17 0.00
13-02-03
00-00
00-00
22443-22444/
1
1
M100
FL18 0.00
09-11-01
00-00
00-00
22443-22444/
1
1
M100
FL19 0.00
04-09-01
00-00
00-00
22443-22444/
1
1
M100
FL20 0.00
05-09-12
00-00
00-00
22443-22444/
3
1
M100
FL21 0.00
10-05-00
00-00
00-00
22443-22444/
3
1
M100
FL22 0.00
10-05-00
00-00
00-00
2/2
2/2 \\\\✓' �/
2/2 jjj�j 1'�-�Jjj
Online PlmTM 0 Copyright MTe1O 1996-1011 Version 28.0.006 Summary Page'Pweu Report DaleOWVI1 Pege:4
Job
Mark
Quan Type
Span
P1-H1
Left OH
Right OH
Engineering
22443-22444
AOIG
I
1*2P Sp
290711
3.203
0
0
#22443-44 - MEL-RY - MORADI
HO 3-14
NO 3-14
TC1 7-0-0
12-2-6
1
6-7-5
1 3_10-0
3.203
Sx8
3.6
2.4
6xe
4x8
H
N
O
C
3.179
- .Sx8"
_
-�1.548
.5x6
2-22-55y Q
. _..
D
Y=6& 46
9xE6
A
e I
M
L
J
3x6
3x6
4.8
18G-MTSH-Sx10 2x4
F
7x8
5x8 �1
5x6
0.9926
�- 5.6
IIIIII������111
Cant: I- 0- 0 M
�1
_ M Cant:11-15
WII:80II0
W:801
R:2560
R:2488
U:2121
U:2045
BC - - -7-0
1
11-9-126-4-
2-6-4 1-8-
29-7-11
EXCEPT AS SHOWN ALL PLATES ARE MT2020
Scale: 0.211" =1' .
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
ttttttttttrtt+t
* 2-Ply Truss
ttttttttttttttt
CSI -Size- ----Lumber----
TC 0.96 2x 4 SP-#1
-- 0.89 2x 4 SP-#2
A -B B -C C -D
BC 0.94 2. 4 SP-#2
-- 0.92 2x 4 SP-#1
I -H
-- 0.82 2x 4 SP-SS
H -G G.-F F -E
WB 0.63 2x 4 SP-#3
Brace truss as follows:
0. C. From To
TO Cont. '0- 0- 0 29- 7-11
BC Cont. 0- 0- 0 29- 7-11
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.00 Fc=1.00 Ft=1.00
BC Fb=1.00 Fc=1.00 Ft=1.00
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
J 2561 2122 U 157 R
F 2489 2045 U 175 R
at Brg Size Required
J 8.0" I.S.
F B.I. 1.5"
LC# 1 Standard Loading
Dur Fctre - Lbr 1.25 Plt 1.25
plf - Dead Live* From To
TC V 30 40 0.0' 29.61
BC V 10 0 0.0' 29.6'
TO V 38 50 8.01 28.01
BC V 13 0 8.01 28.01
BC V 180 180 7.01 CL-LB
TC V 162 162 7.0' CL-LB
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Cass(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CHI P Los Axl-CSI-Bnd
MiTek® Online Plus-
---------- Top Chords ----------
A -Q 0.23 482 T 0.00 0.23
Q -B 0.57 8298 C 0.47 0.10
B -N 0.83 11029 C 0.64 0.19
N -0 0.89 11943 C 0.69 0.20
O -C 0.83 11943 C 0.69 0.14
C -P 0.75 10903 C 0.63 0.12
P -D 0.60 7244 C 0.42 0.18
D -E 0.96 7083 C 0.08 0.88
--------Bottom Chords ---------
* -J 0.20 460 C 0.03 0.17
J -I 0.63 5778 T 0.53 0.10
I -M 0.74 7979 T 0.57 0.17
M -L 0.92 11029 T 0.80 0.12
L -H 0.90 10796 T 0.78 0.12
H -E 0.54 10386 T 0.49 0.05
K -G 0.92 10394 T 0.49 0.33
G -F 0.73 6723 T 0.32 0.41
F -E 0.74 6745 T 0.32 0.42
J -Q
0.63
6167 C
Q -I
0.37
2309 T
I -B
0.06
461 T
8 -M
0.51
3205 T
M -N
0.10
852 C
N -L
0.15
970 T
L -0
0.07
628 T
L -C
0.19
1206 T
H -C
0.06
392 T
H -P
0.07
456 T
K -P
0.06
379 T
P -G
0.34
3478 C
G -D
0.15
964 T
TL Defl -1.44" in L -H L/218
LL Defl -0.58" in L -H L/546
DL Da£1 -0.58" at L L/547
Hz Disp LL DL TL
it F 0.14" 0.21" 0.35"
Shear // Grain in I -I 0.43
Plates for each ply each face.
Plate - MT20 20 Ga, Grose Area
Plate - MT8H 18 Ga. Gross Area
Jt Type Plt Size X Y JSI
A MT20 4.Ox 6.0 Ctr 0.1 0.43
Q MT20 5.0x 8.0-1.0-0.3 0.92
8 MT20 5.Ox 8.0 Ctr-0.1 0.93
E MT20 4.Ox 6.0 Ctr 0.1 0.97
J MT20 5.Ox 8.0 0.5 Ctr 0.86
I MT20 3.Ox 6.0 0.6-0.1 0.81
M MT20 3.Ox 6.0-0.5 Ctr 0.84
H MT8H S.Ox10.0 Ctr-1.0 0.79
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
MC2007
TPI 2002
2 COMPLETE TRUSSES REQUIRED.
Fasten together in staggered
pattern. (1/2" bolts -OR-
sD53 screws -OR- 10d nails
as each layer is applied.)
----Spacing (In) ----
Rows Nails Screws Bolts
TC 1 12 24 0
BC 1 12 24 0
WB 1 8 8
This truss has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truas is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 2.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
BC Dead Load 3.0 psf
Max comp. force 11943 Lbs
Max tens. force 11029 Lbs
Connector Plate Fabrication
Tolerance =-20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 5 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. IIICAUTIONII! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus^' C Copydght Mtrek®1996-2011 Version 28.0.008 Englneenng -PoNait =1111 10:27:55AM Pagel
Job
Mark
Quan Type
Span
Pl-Hl Left OH
Right OH
Engineering
22443-22444
A02
1 SP
291013
3.179 0
0
FJ2443-44 - MEL-RY
- MORADI
NO 3-13
NO 3-14
.1
TCj7-0-9
1 4-2-1 1
9-8-4
1
8-11-144
1.547r Sx6
3x6
5.5
5x8 C
L
D
�3.203
-- -- 3 .179�
B
3x12
2-8-11 2x4
M
Qj
-/tl 4x6 N
5x5
A
EP
J I
H
R
Sx8 5x8 0.4832
--
Sx8
0 G
�
13x4#3x4
5.5 -
Cent: 1- 0- 3 7
0.9926
7 Cant:l- 0- 0
W:801
W: 800
R:1164
R:1227
U: 986
U:1041
BC_8_2 _
- q_ _
_ _
_ _ - _
ALL PLATES ARE MT2020, # - PLATE SELECTED IN PLATE MONITOR
Scale: 0.204" = 1'
Online Plus -- version 28.0.006
RUN DATE: 27-MAY-11
CHI -Size- ----Lumber----
TC 0.71 2X 4 SP-SS
-- 0.58 2x 4 SP-#2
B -C C -D D -E
BC 0.94 2x 4 SP-#1
-- O.B5 2x 4 SP-#2
A -K K -J J -I
WE 0.39 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 29-10-13
BC Cont. 0- 0- 0 29-10-13
psf-Ld Dead Live
TC 15.0. 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 2.25
Plate Duration Factor 1.25
TO Fb-1.15 Fc=1.10 Ft-1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
K 1164 987 U 53 R
G 1228 1042 U 39 R
Jt Beg Size Required
x 8.1^ 1.5"
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr
CSI
P Lbs
Axl-CSI-Bnd
__________Top Chords_____-_---
- -N
0.71
3070 C
0.04
0.67
N -B
0.36
3637 C
0.19
0.17
B -C
0.50
3918 C
0.41
0.09
C -L
0.58
3889 C
0.41
0.17
L -D
0.51
3297 C
0.34
0.17
D -M
0.49
3372 C
0.34
0.15
M -E
0.42
1161 C
0.01
0.41
-------- Bottom Chords _______-_
A -K
0.85
2875 T
0.48
0.37
MiTek® Online Plus^
x -J
0.85
2880 T
0.48
0.37
J -I
0.84
3548 T
0.59
0.25
I -H
0.87
4052 T
0.34
0.53
e -0
0.64
2699 T
0.22
0.42
o -G
0.93
1049 T
0.13
0.80
G -E
0.94
1107 T
0.14
0.80
N -J
0.21
672 T
J -B
0.04
153 T
B -I
0.14
461 T
I -C
0.07
259 T
I -L
0.10
236 T
L -H
0.39
807 C
H -D
0.17
537 T
H -M
0.18
583 T
M -O
0.39
1002 C
TL Defl -0.93" in I -H L/340
LL Defl -0.36" in I -H L/886
DL Defl -0.36" at I L/893
Hz Disp LL DL TL
it G 0.11" 0.17" 0.28"
Shear // Grain in O -G 0.97
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Axes
Plate - MTBH 20 Ga, Gross Area
Jt Type Plt Size K Y JSI
A MT20 4.Ox 6.0 Ctr 0.2 0.85
B MT20 S.Ox 8.0 1.0 0.1 0.71
M 14T20 3.Oxl2.0 1.9-0.5 0.78
E MT20 S.Ox 5.0-0.6 0.6 0.43
I MT20 S.Ox 8.0 Ctr-1.0 0.76
H MT20 S.Ox 8.0 1.0-1.0 0.99
G# MT20 3.Ox 4.0-0.1 0.1 0.58
# = Plate Monitor used
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
NOTE: USER MODIFIED PLATES
This design may have plates
selected through a plate
monitor.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 3918 the
Max tens. force 4052 Lbs
Connector Plate Fabrication
Tolerance = 20%
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,PL 34946
S. Salim Carol, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EH5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
!!!CAUTION!!! READ "SCSI-Bl
SUMMARY SHEET' BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online PNs" 0 Copyright RLTeIis 1996-2011 Vemlon 28.0.008 Engneenn9- Ponmit 6=01 1 10:28:00 AM Pagel
Job
Mark
Quan
Type
Span
pi -HI
Left OH Right
OH
I Engineering
22443-22444
A03
1 1
SP
300112
3.179
0 0
#T2443-44 - MEL-RY - MORADI
HO 3-13
HO 3-14
TC�
10-3-0 1108121
7-2-1
1
10-11-15
5.8
Sx5
3x6
3x5
-�
3.179(- 1.548 r-B
C
P
D
----13.203
3.6
3.8
3-3-1
L,
M
8-11J
4x6
4.6
-
9-72
_
F
9-7H A
K
N 6.8
5.8
�0.4832
5x8
0
G
' #316
2x4-0.9926
1- 3x4
#3x6
Cant:l- 0- 3 fl
fl Cant:l- 0- 0
W:801
W:800
R:1173
R:1237
U: 994
U:1049
BC 1-8-2
e_9_
_ _
_ _g
_8_
I
30-1-12
ALL PLATES ARE MT2020, # = PLATE SELECTED IN PLATE MONITOR
Scale: 0.203" = 1'
MiTek® Online Plus"
Online Plus -- Version 28.0.006
K -N 0.84 2581 T 0.34 0.50
2- 0- 0 wide
RUN DATE: 27-MAY-11
N -J 0.74 3481 T 0.28 0.46
will fit between the H.C.
J -I 0.80 3387 T 0.36 0.44
and any other member.
CHI -Size- ----Lumber----
I -H 0.81 3437 T 0.37 0.44
Design checked for 10 psf non-
TC 0.60 2x 4 SP-#2
H -0 0.50 2951 T 0.15 0.35
concurrent LL on BC.
BC 0.84 2x 4 SP-#1
0 -G 0.72 1280 T 0.11 0.61
NOTE: USER MODIFIED PLATES
-- 0.72 2x 4 SP-SS
G -F 0.72 1334 T 0.11 0.61
This design may have plates
A -K R -G G -F
-------------Webs-------------
selected through a plate
-- 0.81 2x 4 SP-#2
N -L 0.23 970 C
monitor.
J -I I -H
L -J 0.05 233 T
Wind Loads - ANSI / ASCE 7-05
WB 0.42 2x 4 SP-#3
J -B 0.13 429 T
Truss is designed as a Main
B -I 0.05 277 C
Wind -Force Resistance System.
Brace truss as follows:
I -C 0.07 245 T
Wind Speed: 140 mph
O.C. From To
I -P 0.05 180 T
Mean Roof Height: 20-0
TC Cont. 0- 0- 0 30- 1-12
P -H 0.10 356 T
Exposure Category: C
BC Cont. 0- 0- 0 30- 1-12
H -D 0.15 494 T
Occupancy Factor : 1.00
H -M 0.10 323 T
Building Type: Enclosed
psf-Ld Dead -.'Live
M -0 0.42 1801 C
Zone location: Exterior
TC 15.0 20.0
TO Dead Load 9.0 psf
BC 5.0 0.0
TL Defl -0.76" in I -H L/421
BC Dead Load 3.0 psf
TC+BC 20.0 20.0
LL Defl -0.30" in I -H L/999
Max comp. force 3506 Lbs
Total 40.0 Spacing 24.0"
DL Defl -0.30" at I L/999
Max tens. force 3481 Lbs
Lumber Duration Factor 1.25
Hz Diap LL DL TL
Connector Plate Fabrication
Plate Duration Factor 1.25
Jt G 0.10" 0.15" 0.26"
Tolerance = 20%
- TC E'b=1.15 Fc=1.10 Ft=1.10
Shear // Grain in O -G 0.92
This truss is designed for a
BC Fb=1.10 Fr-1.10 F1r1.10
creep factor of 1.5 which
Plates for each ply each face.
is used to calculate total
Total Load Reactions (Lbs)
Plate - MT20 20 Ga. Gross Area
load deflection.
Jt Down Uplift Horiz-
Plate - 14TBH 2O Ga, Gross Area
FABRICATOR NOTES:
K 1174 995 U 64 R
Jt Type Plt Size X Y JSI
1. EAST COAST TRUSS
G 1237 1049 U 59 R
A MT20 4.Ox 6.0 Ctr 0.2 0.77
5285 ST.LUCIE BLVD.
L MT20 3.Ox 6.0-1.4-0.6 0.79
FORT PIERCE,FL 34946
Jt Brg Size Required
B 14T20 5.Ox 8.0 0.5 0.1 0.68
K 8.1" 1.5"
M MT20 3.Ox 8.0 1.8-O.e 0.81
S. Selim Cerci, P.E.
G 8.0" 1.5"
F MT20 4.Ox 6.0 Ctr 0.1 0.44
5407 Wellcraft Dr.
K# MT20 3.Ox 6.0-0.2 0.2 0.84
Greenacres, FL.33463
Plus 6 Wind Load Case(s)
I MT20 5.Ox 8.0 Ctr-1.0 0.65
Plus 1 UBC LL Load Case(s)
H MT20 5.Ox 8.0 1.0-1.0 0.84
MAURICE A. SHASHOUA,
Plus 1 DL Load Case(s)
O 14T20 3.Ox 4.0-0.5-0.2 0.91
P.E.#EB5251 6 19554
G# MT20 3.Ox 6.0-0.1 0.2 0.44
1908 NW 112 AVE.
• Checked for NonConcurrent 200
CORAL SPRINGS, FL 33071
Lbs Moving Point Load applied
# = Plate Monitor used
2. !!!CAUTION!!! READ 'SCSI-B1
at Panel Points and Mid -panel
REFER TO ONLINE PLUS GENERAL
SUMMARY SHEET" BEFORE
- on BC
NOTES AND SYMBOLS SHEET FOR
HANDLING , INSTALLING 6
ADDITIONAL SPECIFICATIONS.
BRACING TRUSSES.
Membr CSI P Lbs Axl-CSI-Bnd
3. SEE ATTACHED DETAIL SHEET
--Top Chords----------
NOTES:
FOR: 1-JACK NAILS.
A -L 0.59 2708 C 0.27 0.32
Trusses Manufactured by:
2-TBRACE. 3-BEARING BLACK.
L -B 0.54 3506 C 0.36 0.18
East Coast Truss
B -C 0.41 3355 C 0.36 0.05
Analysis Conforms To:
C -P 0.45 3332 C 0.35 0.10
FBC2007
P -D 0.47 3181 C 0.34 0.13
TPI 2002
D -M 0.60 3265 C 0.34 0.26
This truss has been designed
M -F 0.45 1391 C 0.01 0.44
for 20.0 psf LL on the B.C.
--------Bottom Chords---------
in areas where a rectangle
A -K 0.67 2604 T 0.22 0.45
3- 6- 0 tall by
ONins Plus"' C CopydgM MI7ek®1996-2011 Vembn 28.0.008 EngineeMg
-Portrait 6=011 1028:04 AM Pagel
Job
Marx
Quan
Type
Span Pl-Hl
Left OH Right
OH
Engineering
22443-22444
A04
1 1
Sp
300411 3.179
0 0
#1'2443-44 - MEL-RY
- MORADI
HO 3-13
HO 3-13
VC�
13-1-4
1
4-3-5 1
13-0-2
5.6
5x5
B
C
T
3.179
----13.203
3x6
3x6
3-9-8
K
L
11-7H
Sx6
11-7G 5x6
_ _
E
A
H
G
J
5x8
5x8
M
I
#4x6
2x�0.
9926
2x4
F
#4x6
Cant:1- 0- 3 fj
M Cant:l- 0- 0
W: 801
W:800
R:1215
R:1215
U:1029
U:1028
BC1-B-21
11- -9
1
4-0-7 1
if-9-9
ALL PLATES ARE MT2020, #
= PLATE SELECTED IN PLATE MONITOR
Scale: 0.201" = P
Online Plus -- Version 28.0.006
RUN DATE: 27-MAY-11
CSI -Size- ----Lumber----
TC 0.71 2x 4 SP-SS
-- 0.54 2x 4 SP-#2
B -C
BC 0.77 2x 4 SP-SS
-- 0.65 2x 4 SP-#2
H -G
WE 0.41 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 30- 4-11
BC Cont. 0- 0- 0 30- 4-11
ps£-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
I 1216 1030 U 76 R
F 1215 1029 U 76 R
it Erg Size Required
I 8.1" 1.5"
F 8.0" 1.5"
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MiTek® Online Plus^
H -G 0.65 3186 T 0.53 0.12
G -M 0.54 3605 T 0.31 0.23
M -F 0.77 3590 T 0.31 0.46
F -E 0.77 3589 T 0.31 0.46
------------- Webs -------------
J -K 0.04 181 T
K -H 0.35 526 C
H -B 0.15 475 T
B -G 0.07 204 T
G -C 0.13 443 T
G -L 0.41 538 C
M -L 0.04 196 T
TL Defl -1.03" in G -M L/316
LL Defl -0.41" in G -M L/781
DL Defl -0.39" at G L/834
Hz Disp LL DL TL
it F 0.13" 0.19" 0.32"
Shear // Grain in I -K 0.40
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TSH 20 Ga, Gross Area
it Type Plt Size X Y JSI
A MT20 5.Ox 6.0 1.2 0.7 0.92
B MT20 5.Ox 6.0 0.5 Ctr 0.76
E MT20 S.Ox 6.0-1.2 0.7 0.92
I# M720 4.Ox 6.0 Ctr 0.5 0.94
H MT20 5.Ox 8.0-1.0-1.0 0.78
G MT20 5.Ox 8.0 1.0-1.0 0.78
F# MT20 4.Ox 6.0 Ctr 0.5 0.94
# = Plate Monitor used
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms TO:
FBC2007
TPI 2002
This truss has been designed
for 20.0 pef LL on the B.C.
Membr
CSI
P Lbs
Axl-CSI-Bnd
in areas where a rectangle
----------Top Chords----------
3- 6- 0 tall by
A
-K
0.71
3760 C
0.09
0.62
2- 0- 0 wide
K
-B
0.41
3291 C
0.10
0.31
will fit between the B.C.
B
-C
0.54
3204 C
0.34
0.20
and any other member.
C
-L
0.50
3293 C
0.12
0.38
Design checked for 10 psf non-
*
-E
0.69
3744 C
0.09
0.60
concurrent LL on BC.
--------Bottom Chords---------
NOTE: USER MODIFIED PLATES
A
-L
0.75
3607 T
0.31
0.44
This design may have plates
I
-J
0.75
3609 T
0.31
0.44
selected through a plate
J
-H
0.54
3623 T
0.31
0.23
monitor.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 ps£
BC Dead Load 3.0 pelf
Max comp. force 3760 Lbs
Max tens. force 3623 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAUR ICE A. SHASHOUA,
P.E.#EB5251 & 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3, SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLACK.
Online Plus"' ® CopyrightMHeR®199G-2011 Version 26.0.006 Engineering-PoMait GM01110:26:07 AM Pagel
Job
Mark
Quan
Type Span Pl-Hl
Left OH Right
OH
Engineering
22443-22444
A05
1 1
Sp 300709 3.179
0 0
#22443-44 - MEL-RY
- MORADI
HO 3-13
NO 3-13
TC]
15-4-6
1
15-3-1
5.6
B
3.179F- 3.6
3x6
T
R
N
4.6
-13.203 3.6
4-3-14
Q
0
1-1-9F
4x6
4.6
D
A
F
P
6x8
M
G
3.6
0.9926
3.6
E
5.8
5x8
Cant: 1- 0- 3 M
M Cant: 1- 0- 0
W: 802
W: 800
R:1225
R:1224
U:1037
U:1036
30-7-!
ALL PLATES ARE MT2020
Scale: 0.200" = 1'
MiTek® Online Plus -
Online Plus -- Version 28.0.006
O -D 0.40 1854 C 0.18 0.22
in areas where a rectangle
RUN DATE: 31-MAY-11
--------Bottom Chords---------
3- 6- 0 tall by
A -G 0.88 1858 T 0.31 0.57
2- 0- 0 wide -
CSI -Size- ----Lumber----
G -P 0.89 3781 T 0.38 0.51
will fit between the B.C.
TC 0.62 2x 4 SP-#2
P -F 0.90 3576 T 0.38 0.52
and any other member.
BC 0.90 2x 4 SP-#2
F -M 0.90 3627 T 0.39 0.51
Design checked for 10 pef non-
WB 0.81 2x 4 SP-#3
M -E 0.86 3672 T 0.37 0.49
concurrent LL on BC.
E -D 0.89 1782 T 0.29 0.60
Wind Loads - ANSI / ASCE 7-05
Brace truss as follows:
-------------Webs-------------
Truss is designed as a Main
O.C. From To
G -Q 0.81 2041 C
Wind -Force Resistance System.
TC Cont. 0- 0- 0 30- 7- 9
Q -P 0.05 232 T
Wind Speed: 140 mph
BC Cont. _0- 0- 0 30- 7- 9
P -R 0.11 346 T
Mean Roof Height: 20-0
R -F 0.39 811 C
Exposure Category: C
psf-Ld Dead .Live
F -B 0.36 1136 T
Occupancy Factor : 1.00'
TO 15.0 20.0
F -N 0.46 852 C
Building Type: Enclosed
BC 5.0 0.0
N -M 0.09 288 T
Zone location: Exterior
TC+BC 20.0 20.0
M -0 0.05 159 T
TO Dead Load 9.0 psf
Total 40.0 Spacing 24.0"
0 -E 0.60 2025 C
BC Dead Load 3.0 psf
Lumber Duration Factor 1.25
Max comp. force 3791 Lbs
Plate Duration Factor 1.25
TL Defl -0.78" in P -F L/419
Max tens. force 3781 Lbs
TO Fb=1.15 Fc=1.10 Ft--1.10
LL Defl -0.31" in P -F L/999
Connector Plate Fabrication
BC Fb=1.10 FC`1.10 Ft=1.10
DL Defl -0.31" at F L/999
Tolerance = 20%
Hz D1sp LL DL TL
This truss is designed for a
Total Load Reactions (Lbs)
Jt E 0.12" 0.181, 0.30"
creep factor of 1.5 which
Jt Down Uplift Horiz-
Shear // Grain in E -E 0.64 -
is used to calculate total
G 1225 1037 U 89 R
load deflection.
E 1225 1037 U 89 R
Plates for each ply each face.
FABRICATOR NOTES:
Plate - MT20 20 Ga, Gross Area
1. EAST COAST TRUSS
it Brg Size Required
Plate - MTBH 18 Ga. Gross Area
5285 ST.LUCIE BLVD.
G 8.1^ 1.5.,
Jt Type Plt Size X Y JSI
FORT PIERCE,FL 34946
E 8.0" I.S.
A MT20 4.Ox 6.0 Ctr 0.2 0.57
Q MT20 4.Ox 6.0-1.4-0.4 0.87
S. Salim Cerci, P.E.
Plus 6 Wind Load Case(s)
O MT20 3.Ox 6.0 2.9-0.8 1.00
5407 Wellcraft Dr.
Plus 1 UBC LL Load Case(s)
D MT20 4.Ox 6.0 Ctr 0.2 0.56
Greenacres, FL.33463
Plus 1 DL Load Case(s)
F MT20 6.Ox 8.0 Ctr-0.5 0.70
MAURICE A. SNASHOUA,
Checked for NonConcurrent 200
REFER TO ONLINE PLUS GENERAL
P.E.#EB5251 6 19554
Lbs Moving Point Load applied
NOTES AND SYMBOLS SHEET FOR
1908 NN 112 AVE.
• at Panel Points and Mid -panel
ADDITIONAL SPECIFICATIONS.
CORAL SPRINGS, FL 33071
on BC
2. !!!CAUTION!!! READ 'SCSI-B1
NOTES:
SUMMARY SHEET- BEFORE
Membr CSI P Lbs Axl-CSI-Bnd
Trusses Manufactured by:
HANDLING , INSTALLING 6
----------Top Chords----------
East Coast Truss
BRACING TRUSSES.
A -Q 0.47 1932 C 0.19 0.28
Analysis Conforms To:
3. SEE ATTACHED DETAIL SHEET
Q -R 0.59 3791 C 0.40 0.19
FBC2007
FOR: 1-JACK NAILS.
R -B 0.49 2886 C 0.30 0.19
TPI 2002
2-TBRACE. 3-BEARING BLOCK.
B -N 0.53 2892 C 0.30 0.23
This truss has been designed
N -0 0.62 3784 C 0.39 0.23
for 20.0 psf LL on the B.C.
Onroo PWs°mCopydghtM7ek®1090-2011Version28.0.W EnBmeering-PoNat6/220111028:09AM Pagel
Job
Mark
Quan
Type Span
Pl-Hl
Left OH
Right OH
I Engineering
22443-22444
A06
1
Sp 300914
3.203
0
0
# 2443-44 - MEL-RY
- MORADI
NO 3-14
NO 3-14
TC1
15-4-9
1
15-5-5
5x5
C
B
3.203 r- 3x6
3x6
-�3. 185
T
W
P
3x6
4-5-2
5xfi
S1
Sx6
M
4
1-1-11F 4x6
4.6
A
1
F
D
L J
6x8
O
G
3.6
3x6
E
Sx8
5x8
Cant:l- 0- 0 fl
fl Cant:l- 0- 0
W: 800
W:800
R: 1232
R:1232
U:1044
U:1044
.. 14
"ALL PLATES ARE MT2020
Scale: 0.198" = 1,
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
CSI -Size-
TC 0.59 2x 4 SP-#2
BC 0.89 2x 4 SP-#2
WE 0.82 2x 4 SP-#3
MiTek® Online Plus-
--------
Bottom
Chords ---------
* -G
0.49
467 T
0.07
0.42
G -L
0.75
306E T
0.51
0.24
L -F
0.89
3135 T
0.34
0.55
P -0
0.88
3173 T
0.34
0.54
O -E
0.72
2903 T
0.29
0.43
E -D
0.46
506 C
0.06
0.40
Brace truss as follows:
G
-M
0.62
2996
C 1 Br
O.C. From To
M
-L
0.05
194
T
TC Cont. 0- 0- 0 30- 9-14
L
-N
0.08
262
T
BC Cont. 0- 0- 0 30- 9-14
N
-F
0.31
645
C
One Continuous Lateral Brace
F
-C
0.32
1011
T
G -M
F
-P
0.33
681
C
Attach CLB with (2)-10d nails
P
-O
0.07
246
T
at each web.
O
-Q
0.10
352
T
Q
-E
0.82
3015
C
psf -Id Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TO Fb=1.15 Fo-1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift„ Horiz-
G 1233 1045 U 90 R
E 1233 1045 U 89 R
Jt Erg Size Required
G 8.0" I.S.
E 8.0" 1.5"
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Casa(s)
Plus 1 DL Load Caae(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lba Axl-CSI-Hnd
----------Top Chords ----------
A -M 0.42 489 C 0.00 0.42
M -N 0.53 3228 C 0.33 0.20
N -C 0.47 2598 C 0.27 0.20
C -P 0.53 2602 C 0.27 0.26
P -SS 0.59 3202 C 0.33 0.26
SS-Q 0.56 3253 C 0.33 0.23
Q -D 0.28 519 T 0.00 0.28
TL Defl -0.64" in L -F L/516
LL Defl -0.25" in L -F L/999
DL Defl -0.25" at F L/999
Hz Disp LL DL TL
it E 0.10" 0.15" 0.26"
Shear // Grain in G -G 0.47
Plates for each ply each face.
Plate - MT20 20 Gar Gross Area
Plate - NISH 18 Ga, Gross Area
Jt Type Plt Size R Y JSI
A MT20 4.Ox 6.0 Ctr 0.1 0.43
M MT20 5.Ox 6.0-1.4-0.4 0.88
Q MT20 5.Ox 6.0 1.9-0.5 0.93
D MT20 4.Ox 6.0 Ctr 0.1 0.43
G 14T20 5.0x 8.0 0.5 Ctr 0.86
F MT20 6.Ox 8.0 Ctr-0.5 0.61
E MT20 5.0x 8.0-0.5 Ctr 0.88
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TO Dead Load 9.0 psf
EC Dead Load 3.0 psf
Max comp. force 3253 Lbs
Max tens. force 3173 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
190E NW 112 AVE.
CORAL SPRINGS, FL 33071
!!!CAUTION!!! READ 'SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus"' ®Copyright MiTeM 199 2011 Version 28.0.006 Engineering-Portalt 61212011 111,28.11 AM Pagel
Job
Mark
Quan
Type Span P1-H1
Left OH
Right OH
Engineering
22443-22444
A7
1
Sp 300914 3.203
0
0
#22443-44 - MEL-RY
- MORADI
He3-14
-
SO 3-14
TC�
15-4-15
15-4-15
5.5
B
T3.203f-
3x6
3x6
- -I - -
3x6 '7
K
3.6
5x6 Sl
S2 5.6
4-5-4
I
L
1-1-12E
4x6
4x6
A
8
C
H
6x8
G
F
3.6 1
3x6
D
5x8
5x8
Cant:l- 0- 0 fl
rl Cant: 1- 0- 0
W:800
W:800
R:1232
R:1232
U:1044
U:1044
8C 1-8-
1 -8-
1 -8-15
1-8-0
�30
s 14
ALL PLATES ARE MT2020
Scale: 0.198" = 1'
MiTek® Online Plus -
Online Plus -- Version 28.0.006
--------Bottom Chords---------
RUNDATE: 31-MAY-11
A -F 0.52 488 T 0.08 0.44
F -H 0.75 3068 T 0.51 0.24
CSI -Size- ----Lumber----
H -E 0.88 3138 T 0.34 0.54
TC 0.53 2x 4 SP-#2
E -G 0.88 3138 T 0.34 0.54
BC 0.88 2x 4 SP-#2
G -D 0.75 3068 T 0.51 0.24
WE 0.63 2x 4 SP-#3
D -C 0.52 488 T 0.08 0.44
------------- Webs -------------
Brace truss as follows:
F -I 0.63 2995 C 1 Br
O.C. From To
I -H 0.05 201 T
TC Cont. 0- 0- 0 30- 9-14
H.-J 0.07 248 T
BC Cont. 0- 0- 0 30- 9-14
J -E 0.32 651 C
One Continuous Lateral Brace
E -B 0.32 999 T
F -I L -D
E -K 0.32 651 C
Attach CLB with (2)-10d nails
K -G 0.07 248 T
at each web.
G -L 0.05 201 T
L -D 0.63 2995 C 1 Br
psf-Ld Dead Live
TC 15.0 20.0
TL Defl -0.64" in E -G L/515
BC 5.0 0.0
LL Defl -0.25" in E -G L/999
TC+BC 20.0 20.0
DL Defl-0.251' at E L/999
Total 40.0 Spacing 24.0"
Hz Disp LL DL TL
Lumber Duration Factor 1.25
Jt D 0.101' 0.15" 0.26"
Plate Duration Factor 1.25
Shear // Grain in F -F 0.47
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc-1.10 Ft=1.10
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Total Load Reactions (Lbs)
Plate - MT8H 18 Ga, Grose Area
Jt Down Uplift Horiz-
Jt Type Plt Size K Y JSI
F 1233 1045 U 90 R
A MT20 4.Ox 6.0 Ctr 0.1 0.43
D 1233 1045 U 90 R
I MT20 5.0x 6.0-1.4-0.4 0.88
L MT20 5.0x 6.0 1.4-0.4 0.88
Jt erg Size Required
C 14T20 4.Ox 6.0 Ctr 0.1 0.43
F 8.0" 1.5"
F MT20 S.Ox 8.0 0.5 Ctr 0.86
D 8.0" 1.5"
E MT20 6.Ox 8.0 Ctr-0.5 0.60
D MT20 5.Ox 8.0-0.5 Ctr 0.86
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
REFER TO ONLINE PLUS GENERAL
Plus 1 DL Load Case(e)
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
Checked for NonConcurrent 200
-
Lbs Moving Point Load applied
NOTES:
at Panel Points and Mid -panel
Trusses Manufactured by:
on BC
East Coast Truss
Analysis Conforms To:
Membr CSI P Lbs Axl-CSI-Bnd
FBC2007
----------Top Chords----------
TPI 2002
A -I 0.42 510 C 0.00 0.42
This truss has been designed
I -S1 0.47 3258 C 0.33 0.14
for 20.0 psf LL on the B.C.
SS-J 0.53 3215 C 0.33 0.20
in areas where a rectangle
J -B 0.47 2594 C 0.27 0.20
3- 6- 0 tall by
B -K 0.47 2593 C 0.27 0.20
2- 0- 0 wide
K -S2 0.53 3215 C 0.33 0.20
will fit between the B.C.
S2-L 0.47 3258 C 0.33 0.14
and any other member.
L -C 0.42 510 C 0.00 0.42
Design checked for 10 psf non-
Cnfne Plus"' *Copyright MTek®1996-2011 Version 28.0.006 Engineering
-PoNad 602011 10:28:13 AM Pagel
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 3258 Lbs
Max tens. force 3138 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Joe
Nark
Quan Type
Span
Pl-Hl Left OH
Right OH
Engineering
22443,22444
A8
1 1 CAT5
300914
3.203 0
0
22443-44 - MEL-RY
- MORADI
SO3-14
No 3-14
TC�
15-4-15
15-4-15
Sx5
H
T
3.203 (--3
x6 3.6
3.6 3.6
82 J
K Sl
5x6
5x6
4-5-4
I
L
1-1-12E
4x6
4.6
A
E
C
N �1
6x8
G
F
3.6
3.6
D
#5x8
#4x8
Cant:l- 0- 0 ri
fl Cant:l- 0- 0
W:800
W:800
R:1232
R:1232
U:1044
U:1044
HC 1-8-0
1 -8-15
3- -
1- -
30-9-14
ALL PLATES ARE MT2020,
# = PLATE SELECTED IN PLATE MONITOR
Scale: 0.198" = 1'
MiTekO Online Plus -
Online Plus -- Version 28.0.006
--------Bottom Chords---------
Design checked for 10 psf non -
RUN DATE: 31-MAY-11
A -F 0.50 473 T 0.07 0.43
Concurrent LL on BC.
F -H 0.75 3077 T 0.51 0.24
NOTE: USER MODIFIED PLATES
CHI -Size ------ Lumber----
H -E 0.89 3139 T 0.34 0.55
This design may have plates
TC 0.54 2x 4 SP-#2
E -G 0.89 3139 T 0.34 0.55
selected through a plate
BC 0.89 2x 4 SP-#2
G -D 0.75 3077 T 0.51 0.24
monitor.
WB 0.62 2x 4 SP-#3
D -C 0.50 473 T 0.07 0.43
Wind Loads - ANSI / ASCE 7-05
-------------Webs-------------
Truss is designed as a Main
Brace truss as follows:
F -I 0.62 2995 C 1 Br
Wind -Force Resistance System.
O.C. From To
I -H 0.05 191 T
Wind Speed: 140 mph
TC Cont. 0- 0- 0 30- 9-14
H -J 0.08 264 T
Mean Roof Height: 20-0
BC Cont. 0- 0- 0 30- 9-14
J -E 0.32 647 C
Exposure Category: C
One Continuous Lateral Brace
E -B 0.32 1004 T
Occupancy Factor : 1.00
F -I L -D
E -K 0.32 647 C
Building Type: Enclosed
Attach CLB with (2)-10d nails
K -G 0.08 264 T
Zone location: Exterior
at each web.
G -L 0.05 191 T
TC Dead Load : 9.0 psf
L -D 0.62 2995 C 1 Br
BC Dead Load : 3.0 psf
psf-Ld Dead Live
Max comp. force 3240 Lbs
TC 15.0 20.0
TL Defl -0.65" in E -G L/511
Max tens. force 3139 Lbs
BC 5.0 0.0
LL Defl -0.25" in E -G L/999
Connector Plate Fabrication
TC+HC 20.0 20.0
DL Defl -0.25" at E L/999
Tolerance = 20%
Total 40.0 Spacing 24.0"
Hz Disp LL DL TL
This truss is designed for a
Lumber Duration Factor 1.25
it D 0.10" 0.15" 0.26"
creep factor of 1.5 which
Plate Duration Factor 1.25
Shear // Grain in F -F 0.47
is used to calculate total
TC Fb=1.15 Fc=1.10 Ft=1.10
load deflection.
BC Fb=1.10 Ft 1.10 Ft=1.10
Plates for each ply each face.
FABRICATOR NOTES:
Plate - MT20 20 Ga, Gross. Area
1. EAST COAST TRUSS
Total Load Reactions (Lbs)
Plate - 14TBH 20 Ga, Grose Area
5285 ST.LUCIE BLVD.
it Down Uplift Horiz-
it Type Plt Size K Y JSI
FORT PIERCE,FL 34946
F 1233 1045 U 90 R
A MT20 4.Ox 6.0 Ctr 0.1 0.43
D 1233 1045 U 90 R
I MT20 5.Ox 6.0-1.4-0.4 0.88
S. Salim Cerci, P.E.
L MT20 S.Ox 6.0 1.4-0.4 0.88
5407 Wellcraft Dr.
it Erg Size Required
C MT20 4.Ox 6.0 Ctr 0.1 0.43
Greenacres, FL.33463
F 8.0" 1.5"
F# MT20 5.Ox 8.0 1.2 2.9 0.88
D 8.0" 1.5"
E MT20 6.0x 8.0 Ctr-0.5 0.60
MAURICE A. SHASHOUA,
D# MT20 4.Ox 8.0-2.6 3.0 0.93
P.E.#EB5251 6 19554
Plus 6 Wind Load Case(s)
190E NW 112 AVE.
Plus 1 UBC LL Load Cane(s)
# = Plate Monitor used
CORAL SPRINGS, FL 33071
Plus 1 DL Load Case(s)
REFER TO ONLINE PLUS GENERAL
2. I!!CAUTION!!I READ "SCSI-B1
NOTES AND SYMBOLS SHEET FOR
SUMMARY SHEET" BEFORE
Checked for NonConcurrent 200
ADDITIONAL SPECIFICATIONS.
HANDLING , INSTALLING 6
Lbs Moving Point Load applied
BRACING TRUSSES.
at Panel Points and Mid -panel
NOTES:
3. SEE ATTACHED DETAIL SHEET
• on BC
Trusses Manufactured by:
FOR: 1-3ACK NAILS.
East Coast Truss
2-TBRACE. 3-HEARING BLOCK.
Membr CSI P Lbs Axl-CSI-Bnd
Analysis Conforms To:
----------Top Chords----------
FBC2007
A -I 0.43 495 C 0.00 0.43
TPI 2002
I -S2 0.48 3240 C 0.33 0.15
This truss has been designed
S2-J 0.54 3197 C 0.34 0.20
for 20.0 pef LL on the B.C.
J -E 0.47 2598 C 0.27 0.20
in areas where a rectangle
e -K 0.47 2598 C 0.27 0.20
3- 6- 0 tall by
K -S1 0.54 3197 C 0.34 0.20
2- 0- 0 wide
S1-L 0.46 3240 C 0.33 0.15
will fit between the B.C.
L -C 0.43 495 C 0.00 0.43
and any other member.
Online Plus- 0 Copyright MITek®1996-2011 Verelon 28.0.006 Engineering -Portrait 6=011 10:28:15 AM Pagel
Job
Mark
Quan
Type
Span
Pl-Hl
Left OH
Right OH
Engineering
22443-22444
A9
1 1
SP
300914
3.203
0
0
,#22443-44 - MEL-RY - MORADI
BO 3-14
SO 3-14
TC�12-8-6
1
3-10-14 1
14-2-10
5.6
5.8
C
T
3.203F-
1.25-B
-�3.203
5.8
5.6
4-1-7
L
M
1-0-14G
1-1-6F 4x6
4.6
A
-J 1
J
G F
5x5
1
D
K
3x6
6.6 _
0.3903
1
R
2.4
3.6
E
55.8
5.8
Cant:l- 0- 0 rl
M Cant:l- 0- 0
W:800
W:800
R:1232
R:1232
U:1044
U:1044
BC -0
1
N
-4-911-8-01
0
n
0
ag
30-9-14
ALL PLATES ARE MT2020
Scale: 0.198" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
CSI -Size- ----Lumber----
TC 0.70 2x 4 SP-#2
BC 0.91 2x 4 SP-#2
WE 0.67 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 30- 9-14
HC Cont. 0- 0- 0 30- 9-14
One Continuous Lateral Brace
H -L M -E
Attach CLB with (2)-10d nails
at each web.
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lba)
it Down Uplift Horiz-
H 1233 1045 U 83 R
E 1233 1045 U 74-R
Jt Erg Size Required
H 8.0" 1.5"
E 8.0" 1.5"
Plus 6 Wind Load Case(s)
Plus 1 UEC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConourrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr
CSI
P Lbs
Axl-CSI-End
----------Top Chords ----------
* -L
0.53
512 C
0.00 0.53
L -B
0.57
3031 C
0.32 0.25
B -C
0.39
2899 C
0.31 0.08
C -M
0.70
3390 C
0.37 0.33
M -D
0.63
603 C
0.00 0.63
--------Bottom
Chords ---------
A -H
0.48
491 T
0.08 0.40
MiTeke Online Plus-
* -K
0.89
3210 T
0.53
0.36
K -J
0.81
3217 T
0.36
0.45
J -G
0.63
2926 T
0.31
0.32
G -F
0.52
2780 T
0.46
0.06
F -I
0.87
2684 T
0.29
0.58
I -E
0.91
3283 T
0.55
0.36
E -D
0.54
B78 T
0.09
0.45
H -L 0.60 2900 C 1 Br
K -L 0.06 205 T
L -J 0.29 447 C
J -B 0.11 343 T
B -G 0.04 212 C
G -C 0.07 246 T
F -C 0.15 480 T
C -I 0.62 704 T
I -M 0.08 325 T
M -E 0.67 2873 C 1 Br
TL Defl -0.70" in F -I L/472
LL Defl -0.27" in F -I L/999
DL Defl -0.26" at F L/999
Hz Disp LL DL TL
it E 0.11" 0.16" 0.26"
Shear // Grain in E -E 0.64
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MTSH 18 Ga. Gross Area
Jt Type Plt Size X Y JSI
A MT20 4.Ox 6.0 Ctr 0.1 0.43
L MT20 5.Ox 8.0-0.5-0.1 0.83
B MT20 5.Ox 8.0 0.5 0.1 0.49
C Mr20 5.0x 6.0-0.3-0.4 0.86
M MT20 5.Ox 6.0 1.5-0.4 0.85
D MT20 4.Ox 6.0 Ctr 0.1 0.43
J MT20 3.Ox 6.0-1.1-0.1 0.39
F MT20 5.Ox 5.0 Ctr-0.9 0.84
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007-
TPI 2002
This truss has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
RC Dead Load 3.0 pef
Max comp. force 3390 Lbs
Max tens, force 3283 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 4 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION111 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus"'CCopoght MTekOl9 2011Version28.0.006 Engineering-PoWk 6nn01110:28:18AM Pagel
Job
Mark
Quan
Type Span Pi -Hi
Left OH Right
OH
Engineering
22443-22444
A10
1 1
SP 300914 3.203
0 0
##?2443-44 - MEL-RY
- MORADI
HO 3-14
NO 3-14
TC,
12-10-12
1 8-3-0
9-8-2
Sx5
g 3.6
_T_
3.203�
Sx16
M
�1.25
Sx8
C �3.203
3-9-3
L
5x6
N
1-0-1G 4x6
46
9-13F
A
G F
D
g
x
3.6
5x6 0.3903 - 6.6
3.6
g
6x6
2x4J 1
1�
3x8
Cant:l- 0- 0 M
fl Cant: 1- 0- 0
W:800
W:800
R:1232
R:1232
U:1044
U:1044
HC - -
-0-
5-7-7
9- -1
- -
v
3 o 14
All. PLATES ARE MT2020
Scale: 0.198" = 1'
MiTek® Online Plus -
Online Plus -- Version 28.0.006
K -J 0.79 3257 T 0.54 0.25
RUN DATE: 31-MAY-11
J -G 0.62 2638 T 0.31 0.31
G -F 0.75 3422 T 0.37 0.38
CSI -Size- ----Lumber----
F -I 0.67 3205 T 0.33 0.34
TC 0.62 2x 4 SP-#2
I -E 0.79 2964 T 0.30 0.49
BC 0.98 2x 4 SP-#2
E -D 0.55 509 T 0.08 0.47
WE 1.00 2x 4 SP-#3
------------- Webs -------------
H -L 0.55 2678 C 1 Br
Brace truss as follows:
K -L 0.07 235 T
O.C. From To
L -J 0.06 258 T
TC Cont. 0- 0- 0 30- 9-14
J -B 0.14 456 T
BC Cont. 0- 0- 0 30- 9-14
B -G 0.20 637 T
One Continuous Lateral Brace.
G -M 0.11 396 C
H -L
M -F 0.05 174 T
Attach CLS with (2)-10d nails
F -C 0.11 361 T
at each web.
I -C 0.06 216 T
I -N 0.09 335 T
psf-Ld Dead Live
N -E 1.00 2953 C
TC 15.0 20.0
BC 5.0 0.0
TL Defl -0.70" in G -F L/470
TC+BC 20.0 20.0
LL De£1 -0.28" in J -G L/999
Total 40.0 Spacing 24.0"
DL Defl -0.28" at G L/999
Lumber Duration Factor 1.25
Hz Disp LL DL TL
Plate Duration Factor 1.25
Jt E 0.11" 0.16" 0.27"
TC Fb=1.15 Fc=1.10 Ft=1.10
Shear // Grain in H -H 0.63
BC Fb=1.10 Fc=1.10 Ft=1.10
Plates for each ply each face.
Total Load Reactions (Lbs)
Plate - MT20 20 Ca, Gross Area
Jt Down Uplift Soria-
Plate - MT8H 18 Gar Gross Area
H 1233 1045 U 55 R
Jt Type Plt Size X Y JSI
E 1233 1045 U 75 R
A MT20 4.Ox 6.0 Ctr 0.1 0.43
L MT20 S.Ox16.0-1.9-0.5 0.75
Jt Erg Size Required
C MT20 S.Ox 8.0-0.5 0.1 0.52
H 8.0" 1.5"
N MT20 5.Ox 6.0 1.9-0.5 0.93
E 8.0" 1.5"
D MT20 4.Ox 6.0 Ctr 0.1 0.43
H MT20 6.Ox 6.0 0.5 Ctr 0.93
Plus 6 Wind Load Case(s)
G MT20 5.0x 6.0 Ctr-0.9 0.87
Plus 1 UBC LL Load Case(s)
I MT20 3.Ox 6.0 1.1-0.1 0.39
Plus 1 DL Load Case(s)
E MT20 S.Ox 8.0-0.5 Ctr 0.88
Checked for NonConcurrent 200
REFER TO ONLINE PLUS GENERAL
Lbs Moving Point Load applied
NOTES AND SYMBOLS SHEET FOR
at Panel Points and Mid -panel
ADDITIONAL SPECIFICATIONS.
on HC
NOTES:
Membr CSI P Lbs Axl-CSI-Bnd
Trusses Manufactured by:
----------Top Chords----------
East Coast Truss
A -L 0.56 631 C 0.00 0.56
Analysis Conforms To:
L -B 0.62 3209 C 0.34 0.28
FBc2007
B -M 0.46 3092 C 0.33 0.13
TPI 2002
M -C 0.47 3406 C 0.36 0.11
This truss has been designed
C -N 0.49 3301 C 0.34 0.15
for 20.0 psf LL on the B.C.
N -D 0.38 533 C 0.00 0.38
in areas where a rectangle
--------Bottom Chords---------
3- 6- 0 tall by
A -H 0.56 604 T 0.20 0.46
2- 0- 0 wide
H -K 0.98 3133 T 0.52 0.46
will fit between the H.C.
Online Phis^ C Ccpoght MRek®1996-2011 Version 28.0.008 Engineering -Pomeit 6=01110:2&n AM Pagel
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
BC Dead Load 3.0 psf
Max comp. force 3406 Lbs
Max tens. force 3422 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EH5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
!!!CAUTION!!! HEAD "BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Job
Mark
Quan
Type
Span Pl-Hl Left OH
Right OH
Engineering
22443,22444
All
1
I
SP
300915 3.203 0
0
# 2443-44 - MEL-RY - MORADI
SO 3-14
BO 3-14
TC11-6-14
1
12-7-2 1
6-7-15
5.5
3.203(-
B
3x6
Sx6
I �1.25 6x6
3-4-15
K
C
�3.203
30-11G 4.6
4x6
6-13F A
G.
D
-L $
5x16
0.3903 - 6.8
E
5x8
-0.9999
1i 6x6
Cant:l- 0- 0 M
M Cant:l- 0- 0
W:800
W:900
R:1233
R:1233
U:1044
U:1044
BC - _
_ _
_ _
_ _ 4 - _
TALI.
30-9-15
Da
PLATES ARE M2020
Scale: 0.198" = 1'
MiTekO Online Plus -
Online Plus -- Version 28.0.006
L -C 0.79 3832 C 0.39 0.40
RUN DATE: 31-MAY-11
C -D 0.87 1270 C 0.00 0.87
--------Bottom Chords---------
CSI -Size- ----Lumber----
A -H 0.88 817 T 0.13 0.75
TC 0.87 2x 4 SP-#1
H -G 0.86 3163 T 0.25 0.61
-- 0.79 2x 4 SP-#2
G -F 0.65 4133 T 0.22 0.43
A -B B -C
F -E 0.91 3313 T 0.43 0.48
BC 0.91 2x 4 SP-#1
E -D 0.78 1188 T 0.16 0.62
-- 0.88 2x 4 SP-#2
------------- Webs -------------
A -H E -D
H -K 0.68 2963 C 1 Br
-- 0.65 2x 4 SP-SS
K -G 0.10 321 T
G -F
B -G 0.25 780 T
WB 0.68 2x 4 SP-#3
G -L 0.55 875 T
L -F 0.16 460 T
Brace truss as follows:
F -C 0.18 633 T
O.C. From To
C -E 0.46 2219 C 1 Br
TC Cont. .0- 0- 0 30- 9-15
BC Cont. 0- 0- 0 30- 9-15
TL Defl -1.06" in G -F L/311
One Continuous Lateral Brace
LL Defl -0.41" in G -F L/805
H -K C -E
DL Defl -0.34" at F L/965
Attach CLE with (2)-10d nails
Hz Diap LL DL TL
at each web.
it E 0.12" 0.18" 0.30"
Shear // Grain in E -E 0.98
psf-Ld Dead Live
TC 15.0 20.0
Plates for each ply each face.
BC 5.0 0.0
Plate - MT20 20 Ga, Gross Area
TC+BC 20.0 20.0
Plate - 14TBH 18 Ga. Gross Area
Total 40.0 Spacing 24.0"
Jt Type Plt Size X Y JSI
Lumber Duration Factor 1.25
A MT20 4.Ox 6.0 Ctr 0.1 0.43
Plate Duration Factor 1.25
K MT20 5.0x 6.0-1.9-0.5 0.94
TO Fb-1.15 Fc=1.10 Ft=1.10
D MT20 4.Ox 6.0 Ctr 0.1 0.43
BC Fb=1.10 Fc=1.10 Ft=1.10
R MT20 5.Ox 8.0 0.5 Ctr 0.93
G MT20 5.Oxl6.0-1.0-0.7 0.71
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
REFER TO ONLINE PLUS GENERAL
H 1233 1045 U 37 R
NOTES AND SYMBOLS SHEET FOR
E 1233 1045 U 71 R
ADDITIONAL SPECIFICATIONS.
Jt Erg Size Required
NOTES:
H 8.0" 1.5"
Trusses Manufactured by:
E 8.0" 1.5"
East Coast Truss
Analysis Conforms To:
Plus 6 Wind Load Cases)
FBC2007
Plus 1 UBC LL Load Case(s)
TPI 2002
Plus 1 DL Load Case(s)
This trues has been designed
for 20.0 pef LL on the B.C.
Checked for NonConcurrent 200
in areas where a rectangle
Lbs Moving Point Load applied
3- 6- 0 tall by
at Panel Points and Mid -panel
2- 0- 0 wide
on BC
will fit between the B.C.
and any other member.
Menbr CHI P Lbs Axl-CSI-Bnd
Design checked for 10 psf non-
---------- Top Chords----------
concurrent LL on BC.
A -K 0.47 B48 C 0.00 0.47
Wind Loads - ANSI / ASCE 7-05
K -B 0.51 3118 C 0.32 0.19
Truss is designed as a Main
e -L 0.59 3301 C 0.34 0.25
Wind -Force Resistance System.
Odin Plus' C Copyngm 6kTek®1998-2011 Vemion 28.0. 0 EngineeMg -Portrait BWOl l 1029:24 AM Pagel
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
BC Dead.Load 3.0 pef
Max comp. force 3832 Lbs
Max tens. force 4133 Lbs
Connector Plate Fabrication
Tolerance = 209:
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellora£t Dr.
Greanacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
111CAUTION111 READ ^SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Job
Mark
Quan
Type Span
Pl-Hl Left
OH Right OH
Engineering
22443-22444
Al2
1 1
SP 300915
3.203 0
0
#22443-44 - MEL-RY - MORADI
NO 3-14
HO 3-14
Tel
10-3-0 1
16-11-4
1 3-7-11
5.5
3.203F_ B
3.6
-r
5x6
M
4x6 3.6
L
SI N �1.25
6x8---13.203
3-0-11
C
9-6G 4x6
_ 4x6
3-13F A
D
.J_
H
G
K 5x5
J
F I f'
3.6
9998
0.3903 -3x6
7x0
1 ` 2x4 5x5
r55.8
Cant:1- 0- 0 n
I Cant: 1- 0- 0
W: 800
W:800
R:1233
R:1233
U:1045
U:1044
BC _3 _ 0 1
9-4-104_
_ 1
1 3-9-10_8_
30-9-15
ALL PLATES ARE MT2020
MSTek0 Online
Plus.
Online Plus -- version 28.0.006
--------Bottom Chords---------
RUNDATE: 31-MAY-11
A
-H
0.39
407
C
0.06
0.33
H
-K
0.77
3077
T
0.51
0.26
CSI -Size- ----Lumber----
K
-G
0.85
3055
T
0.51
0.34
TC 0.76 2x 4 SP-#2
G
-J
0.92
4827
T
0.93
0.29
Be 0.92 2x 4 SP-#1
J
-F
0.91
5136
T
0.42
0.49
-- 0.85 2x 4 SP-#2
F
-I
0.49
2253
T
0.29
0.20
A -H H -G E -D
I
-E
0.85
2216
T
0.29
0.56
WB 0.64 2x 4 SP-#3
E
-D
0.84
869
T
0.14
0.70
_____________Webs_____________
Brace truss as follows:
H
-L
0.61
2999
C
1 Br
O.C. From' To
L
-K
0.03
123
T
TC Cont. 0- 0- 0 30- 9-15
K
-B
0.10
316
T
Be Cont. 0- 0- 0 30- 9-15
B
-G
0.30
936
T
One Continuous Lateral Brace
G
-M
0.64
1341
C
H -L
M
-J
0.12
380
T
Attach CLB with (2)-10d nails
J
-N
0.09
367
T
at each web.
N
-F
0.48
1276
C
F
-C
0.56
1749
T
psf-Ld Dead Live
I
-C
0.05
280
C
TC 15.0 20.0
C
-E
0.31
1451
C
Be 5.0 0.0
TC+BC 20.0 20.0
TL Defl -1.28"
in
J -F
L/257
Total 40.0 Spacing 24.0"
LL Defl -0.51"
in
J -F
L/641
Lumber Duration Factor 1.25
DL De£1 -0.51"
at
J
L/645
Plate Duration Factor 1.25
Hz Disp LL
DL
TL
TC Fb=1.15 Fc:�1.10 Ft=1.10
Jt
E 0.14"
0.21"
0.34"
Be E2>=1.10 Fc=1.10 Ft=1.10
Shear
// Grain
in
E -E
0.86
Total Load Reactions (Lbs)
Plates for each ply each face.
Jt Down Uplift Horiz-
Plate - MT20 20 Ga. Gross Area
H 1233 1045 U 18 R
Plate - MT8H 18 Ga, Gross Area
E 1233 1045 U 66 R
Jt Type Plt Size K Y JSI
A MT20 4.Ox 6.0 Ctr 0.1 0.43
Jt Brg Size Required
L MT20 5.Ox 6.0-0.5-0.1 0.91
H 8.0" 1.5"
S1 MT20 4.Ox 6.0 Ctr-0.2 0.96
E 8.0" 1.5"
N mT20 3.Ox 6.0 2.0-0.4 0.88
C MT20 6.Ox 8.0-1.9-0.7 0.84
Plus 6 Wind Load Case(s)
D MT20 4.Ox 6.0 Ctr 0.1 0.43
Plus 1 UBC LL Load Case(e)
H MT20 S.Ox 8.0 0.5 Ctr 0.84
Plus 1 DL Load Case(s)
G MT20 5.Ox 8.0 Ctr-0.9 0.94
Checked for NonConcurrent 200
REFER TO ONLINE PLUS GENERAL
Lbs Moving Point Load applied
NOTES AND SYMBOLS SHEET FOR
at Panel Points and Mid -panel
ADDITIONAL SPECIFICATIONS.
.
on Be
NOTES:
Membr CSI P Lbe Axl-CSI-Bnd
Trusses Manufactured by:
----------Top Chords----------
East Coast Truss
A -L 0.40 415 T 0.00 0.40
Analysis Conforms To:
L -B 0.51 3196 C 0.34 0.17
FBC2007
B -M 0.59 3340 C 0.37 0.22
TPI 2002
M -S1 0.76 4987 C 0.28 0.48
This trues has been designed
SI-N 0.64 5007 C 0.51 0.13
for 20.0 psf LL on the B.C.
N -C 0.73 3943 C 0.40 0.33
in areas where a rectangle
C -D 0.69 965 C 0.00 0.69
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on Be.
Wind Loads = ANSI / ASCE 7-05
Trues is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
Be Dead Load : 3.0 pef
Max comp. force 5007 the
Max tens. force 5136 the
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
111CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLACK.
Online Plus- O Copyrighl MTekO ISW2011 Version 28.0.006 Engineering-Pomail 602011 10:28:28 AM Pagel
Job Mart
Qum Type
Span
P1-H1 Left OH Right OR
Engineering
22443-22444 A.
1*2P SP
30020B
3.203 0 0
T4092723
#22443-44 - MEL-RY - MORADI
HO 3-14
HO 5-14
m
0
N
0
TC #-8-01 4-11-11 I 8-11-2 I 14-3-0
I 19-6-13 122-6-1 I 28-4-9
0
I to j .
5x5 =
3.203 E:::- B.
3x6=
3x6=
- 3x6-
N
3x6=31 3x6=
2-8-7 M
O
go_I
5x6 =
4x6=
T
8-1G A
C
12F/
t
- L G
E
82 .'oo.a J
4
R .3x6= 5x10=
3x6=
4x6= 3x6=
F IF2z411
#6x8
5x5 = 0.9996
1
=
Cant:l- 0- 0 M
M Cant: 9- 1
W:800
W:308
R:1241
R:1174
D:1053
D: 943
ta_ _ _ _ _ _ _ _
_ _ _ _ _ _
m m
ri O
N
a
O O
m o
N m
ra
30-2_8
..
ALL PLATES ARE MT2020,
# = PLATE BEI.ECTED IN PLATE MONITOR
Bcale:0205'=1'
MiTebb Online Plus- APPROX. TRUSS WEIGHT: 161.2 LBS
Online Plus -- Version 28.D.011
G -N 0.69 5608 T 0.47 0.22
RUN DATE: 01-JUS-31
E -S2 0.72 7251 T 0.60 0.12
S2-J 0.55 7250 T 0.47 0.08
+ 2-Ply Tres. •
J -Q 0.88 6119 T 0.40 0.48 '
+++++++++++++++
Q -F 0.88 6106 T 0.40 0.48
F -9 0.74 6086 T 0.26 0.48
CBI -Size- ----Lumber----
U -T 0.74 6183 T 0.26 0.48
TC 0.86 2a 4 SP-#1
____________Webs_____________
-- 0.48 2z 4 SP-#2
H -M 0.30 2939 C
A -B B -S1
H -L 0.02 193 T
BC 0.88 2z 4 SP-#1
L -E O.D2 219 C
-- 0.72 2z 4 SP-#2
B -G 0.19 1190 T
A -H H -G G -S2
G -N 0.20 1793 C
-- 0.74 2z 4 SP-08
E -N 0.04 311 T
F -T
A -0 0.21 1662 C
We 0.30 2z 4 SP-0
J -O OAT 133 T
J -R 0.18 1165 T
Brace true. as £allows:
Q -R 0.04 352 T
O.C. From, To
'
TO Cont. 0- 0- 0 30- 2- 0
TL Def1 -1.48" in J -Q L/223
DC Coat. 0- 0- 0 30- 2- 8
LL Defl -0.59" in J -Q L/556
LL Cant 0.01- in U -C L/689
p.f-Ld Dead Liva
DL Defl -0.59" at J L/560
TC 15.0 20.0
Ez Disp LL DL TL
HC 5.0 0.0
it U 0.30" 0.14" 0.24"
TC+BC 20.0 20.0
Shear // Grain in F -U 1.00
Total 40.0 Spacing 24.0•
Lumber Duration Factor 1.25
Plates for each ply each fare.
Plate Duratio. Factor 1.25
Plate - =20 20 Gs, Grose Area
TO Fb=1.15 Faml.10 Ft 1.10
Plate - =89 20 G., Gross Area
BC Fbal.10 Fo•1.10 Fb1.10
it Type' Plt Size E Y MI
A Ff120 4.Ox 6.0 Ctz 0.1 0.43
Total Load Reactionn (Lb.)
M =20 3.0. 6.0-1.1-0.3 0.70
it Dom uplift Horiz-
T M72D S.Ox 6.0-3.2 0.3 0.90
H 1241 1053 U 13 R
G =20 S.Ox10.0 1.0-0.9 0.72
U 1175 943 U 53 R
E =20 3.Ox 6.0 1.2 Ctr 0.41
82 W20 4.0. 5.0 Ctz 0.2 0.9D
it Br, Size Required
F# =0 6.Ox 8.0 0.1 1.3 0.60
B 8.0" I.S.
U 3.5" 3.5"
# a Plate Monitor used
REVIEWED BY:
Plan 6 Wind Load Con. (a)
HiT'ek Industries, Inc.
Plus 1 UBC LL Load Came (m)
6904 Parke East Blvd.
Plus 1 DL Load Came (a)
Temps, FL 33610
Checked for NonConcurxmt 200
REFER TO ONLINE PLUS GENERAL
Lb. Moving Point Load applied
NOTES AND SYMBOLS SHEET FOR
at P.nel Pointe sad Mid -panel
ADDITIONAL SPECISICATI0H9.
on HC
MISS:
Much. CSI P Lee Axl-CSI-Bnd
Traces. Xma f.ctured by:
-Top Chords----------
Beet Coast Trues
A -M 0.16 467 T 0.00 0.16
Analysis C..forms To:
M -B 0.23 3096 C 0.16 0.07
FBC2007
e -H 0.29 3979 C 0.20 0.09
TPI 2002
N -0 D.41 5631 C 0.29 0.12
0 -S1 0.48 7263 C 0.38 0.10
S1-R 0.47 7274 C 0.3D 0.17
R -T 0.86 6164 C 0.06 DAD
---Bottom Chords---------
* -N 0.16 457 C 0.02 0.14
e -L 0.36 2919 T 0.24 0.12
L -G 0.40 3182 T 0.26 0.14
2 COMPLSTE TRDSSES BEQDIRRS.
Fasten together in staggered
pattern. (1/2" bolts -OR-
MS3 ..rare -OR- 10d nails
as each layer is applied.)
____spacing (Me)____
Rove Naila Bassin Bolts
TC 1 12 24 0
BC 1 12 24 0
WB 1, 8 8
This trams has been designed
for 20.0 pef LL on the B.C.
in areas .hare a rectangle
3- 6- 0 tall by
2- 0- 0 .id.
Will fit between the B.C.
and say other ,ember.
Design checked for 10 p.f emn-
Concurrent LL an W.
N01E: USER FDDIFIED PLATES
This design may have plates
.slanted through a plate
monitor.
Wind Leads - ANSI / ASCE 7-05
Trans is designed a. a Main
Wiad-Force Resistance System.
Wind Speed: 140 mph
Mean Reef Refight: 20-0
Exposure Category: C
Occupancy Facts. : 1.00
Building Type: Enclosed
Eon. location: Exterior
TC Dead Load 9.0 p.f
BC Dead Load 3.0 p.f
Mmm Camp. fore. 7274 Lb.
Max tons. force MEb1 Comments.,
C.ants. Plata Ha023.atiom
creep xae.�o L:s�.Baacma • "%�I i
is usedg,Y.`ae
lead de6`3•ee pn. 93 380 •'�'y
FL Cert. 6634
June 1,2011
Job
Mack
Ql1BN Type
Span
P1-H1 Left OR
Right OH
Rmo-e-mg
22443-22444
Z
1+zP SP
290013
2.949 0
0
ra#vz�za
#22443-44 - MEL-RY - MORADI
NO 3-13
SO 3-11
n m
rl M
V O
O O
TO 4-3-14
1
11-0-2 1 14-10-2
1
19-5-12 1 24-6-0
r• m
1 27-3-3 fY
6x6= Q3.203
3x4=
4x6=
3x6=
E
I
T
S3 3x6=
D
2-4-3
4x6 =
1.25 C
^"
//1 I "
4x6=
p #4x6 =
M
�lH 2-g4}y 1.25
6-12L rl
_
_
N
m
2x411
3x6=
5x5=3x4=
J
4x4 =
Cent:1- 1-11
W.
W:600 W:6 0
R:1069
R:1545R: 178
U: 801
D:1287U: 246
SO _ _
_ _ _
_4 1
14-4-3 1m - -
n 1 of
m
r4 m m
rNl
N N N
-
29-0-13
ALL PLATES ARE MT2020, # =
PLATE SELECTED IM PLATE MONITOR
Scale: 0.211'=1'
HSTekO online Plus- APPROX. TRUSS WEIGHT; 153.1 IRS
Canon Plus -- Version 28.0.011
E -F 0.40 2147 C 0.00 0.40
RUN DATE: 01-JCN-11
F -B 0.30 1553 T 0.13 0.17
++r•oa+a••a+•+
9 -I 0.22 2503 T 0.12 0.10
• 2-Ply Truax +
--- __-__Becton Chords_________
•++++++++•+++++'
B -N 0.66 6009 T 0.50 0.16
N -H 0.63 6008 T 0.50 0.13
CSI -size- ----Lumber----
M -L 0.39 4476 T 0.37 0.22
TO 1.00 2. 6 SP-#2
L -x 0.43 2058 T 0.17 0.26
-- 0.40 2z 4 SP-42
E -J 0.40 310 T 0.02 0.38
E -F F -H H -I
J -I 0.47 1547 C 0.00 0.47
HC 0.66 2z 4 SP-12
------ _----- Wake _____________
WB 0.27 2z 4 SP-#3
H -C 0.01 251 T
0.15 1557 C
Br... [rase on follore:
M -D 0.04 288 T
O.C. From To
D -L 0.18 2839 C
TO Cont. -2-11- 4 24- 8-10
L -E 0.14 900 T
HC Cont. -2-11- 4 24- 8-10
E -E 0.02 153 T
E -F 0.27 1733 T
pef-Ld Dead Live
F -J 0.23 2153 C
TO 10.0
5.0 20.0
HC 5.0
TL Defl -0.98" in B -H L/295
TC+SC 20.0 20.0
LL Defl -0.39" in B -N L/740
Total 40.0 Spacing 24.0"
DL ➢on -0.39" at N L/735
Lumber Duration Factor 1.25
Hz Drop LL DL m
Plate Duration Factor 1.25
Jt A 0.06" 0.09" 0.15"
TC Fb-1.15 Pc-1.10 F 1.10
Shear // Grain in A -H 0.3B
HC SD=1.30 re-1.30 F 1.10
Plates for each ply each face.
Total Load Reactions (Lbs)
Plate - MT20 20 Go, Gros. Area
Jt Dorn Uplift Horie-
Plate - MOB 20 Go, Grose Area
A 2069 802 U 49 R
Jt Type Plt Size E y JSI
J 1545 =87 V
C MT20 3.0z 6.D 1.1 0.1 0.39
I 179 247 G 23 R
E =20 6.Ox 6.0 Ctr-0.2 0.46
G w Gravity Uplift
H# MT20 4.0z 4.0 Ctr-2.5 0.40
M =20 3.0. 6.0-1.2 Ctr 0.37
Jt Brg Sire Required
L M20 5.Ox 5.0-0.5-0.9 0.82
A 16.9"-51•-to- -34"
E HT20 3.0z 4.0 1.6-0.1 0.76
J B.O. I.S.
I 6.0" 1.5"
# s Plato Monitor need
REVIEWED BY:
LC# 1 Standard Loading
HiTek Induatriee, Iou.
Der Fetze - Lbr 1.25 Ph 1.25
6904 Parka Suet Blvd. .
plf - Used Live+ Prom To
Tampa, FL 33610
TO v 30 40 -4.41 24.71
SC v 10 0 0.01 24.7'
REFER TO ONLINE PLUS GTHI AL
TO v 20 0 -4.4' 0.0'
NOTES AND SDKBOLS SHEM POR
AODITICNAL SPEDISICATIONS.
Plua 6 Wind Load Came (a)
Plus 1 UBC LL Lood Casa (e)
NOTES:
Pluo 1 DL Load Oman to)
?.a... Manufeetured by:
East Count Truea
Mocked for NonConcurrent 200
- Analyela Caere. To:
Lb. Moving Point Load applied
MC2007
at Panel Pointe and Hid -penal
TPI 20D2
on SC
2 COMPLETE TRUSSES REQUIRED.
Fenton together in ataw ... d
Membr CSI P Lbs Aml-CSI-Bnd
pattern. (1/2" bolts -OR-
----------Top Chortle----------
SDS3 acrava -DR- led nail.
A -A 0.03 6 T O.OD 0.03
an each layer is applied.)
A -B 1.00 83 C 0.00 1.00
----Spacing (In)----
H -S1 0.42 6037 C 0.22 0.20
Rors Nail. S..a Suite
91-C 0.35 6016 C 0.22 0.13
TC 1 12 24 0
C -D 0.27 4490 C 0.17 0.10
BC 1 12 24 0
D -E 0.18 2672 C 0.10 0.08
WB 1 B 8
nw.. Avp efw"cW YRW, W' Lfa„ V�•M. 9P nM,
GM.wF". 4+"Y u,nIM1 Nl"R WI Cw,
This truce ban been designed
for 20.0 psf LL . the B.C.
In are. there . rectangle
3- 6- 0 tell by
2- 0- 0 ride
ill fit betze. the B.C.
and 'any other member.
Deelgn chocked for 10 psf non -
concurrent LL on W.
NDTH: USSR NODIFiED PLATES
Th1S doelgn may have Platte
Selected through a plate
mmn.tor.
Wind Load. - ANSI / ASCE 7-05
Trv.e Ss designed as a Hain
Wind -Force Resistance Syetam.
WSM Speed: 140 mph
Hem Roof Haight: 20-0
Bayou. Category: c
Occupancy Factor : 1.00
Building Type: Encloead
2... location: Exterior
TO Dead Load : 9.0 pat
BC Dead Load : 3.0 paf
User -defined rind -exposed BC
regions __F._
21- 0-12 23- 6-15
Haz comp. force 6037 Lb.
Haz te.. force 6009 Me
Connector Plate Fabrication
Tolermea - 20%
This Cruse 18 designed for a
creep factor of 1.5 which
i. need to calculate total
load deflection.
S�OMPS'A
o` 39380 ?�
ATE
^OP ,A��R1�PU�Z%
S
s1O N AXi0�,
FL Cert. 6634
June 1,2011
Jab Mark
Qum Type
Span Pl-Hl
Left OH
Right OH
Engineering
22443-22444 A15
I
1 Sp
230600 2.949
0
0
T4092725
022443-44 - MEL-RY - MORADI
HD 3-14
No 3-11
a a
0 0
m , n
0 0
m r
TC 1 4-3-10 I
10-6-14
I 16-0-14
I'�
23-6-0
4x6.
D
7x8- 4x4
B
�3.203
4x4=
C
" Sx5 -
N
v 1.25
4xBo
2-0-011
1 259�
-�
mW
2.949
1-11-15 I
//I I//��`
3x4=
j-3j A
M9 9 9��R
1
2x411 0.3903
5x8-0 3x4=
G
3x4=
4x6=
Cant:2- 1-11
W:10415
W:800
R: 913
R:1009
U: 667
U: 932
Sc _ _
_ _
_ _
v
0 0
_ _ _ _
rn r
0 0
23-6-0
�
=j
' ALL
PLATES ARE MT2020
Srate:0266`=1'
M1Tek® Online Plus^ APPROX. TRUSS WEIGHT: 121.7 LBS
Online Plus -- Version 28.0.011 Membr CSI P Lbs Axl-CSI-Bnd NOTES:
RUN DATE: 01=JUN-11----------Top Chords---------- Trusses Manufactured by:
A -A 0.04 6 T 0.00 0.04 East Coast Truss
CSI -Size-----Lnmber---- A -I 0.89 70 T 0.00 0.89 Analysis Conforms To:
TC 0.89 2x 6 SP-SS I -S1 0.38 4315 C 0.18 0.20 FEC2007
-- 0.71 2x 6 SP-02 SI-N 0.71 4296 C 0.34 0.37 TPI 2002
SI-B N -B 0.42 2514 C 0.19 0.23 This truss has been designed
-- 0.47 2x 4 SP-82 B -C 0.39 2078 C, 0.23 0.16 for 20.0 psf LL on the B.C.
B -C C -D D -F C -D 0.42 1612 C 0.16 0.26 in areas where a rectangle
BC 0.94 2x 4 SP-01 D -F 0.47 823 T 0.03 0.44 3- 6- 0 tall by
-- 0.74 2x 4 SP-82--------Bottom Chords--------- 2- 0- 0 wide
H -G G -F I -M 0.90 4293 T 0.62 0.28 will fit between the B.C.
WB 0.70 2x 4 SP-43 M -H 0.94 4296 T 0.62 0.32 and any other member.
H -O 0.57 2077 T 0.38 0.19 Design checked for 30 psf non -
Brace truss as follows: O -H 0.58 1594 T 0.29 0.29 concurrent LL on SC.
O.C. From To E -G 0.74 1626 T D.30 0.44 Wind Loads - ANSI / ASCE 7-05
TC Cont. -2-10- 6 19- 2-11 G -F 0.48 810 C O.OD 0.48 Truss is designed as a Main
BC Cont. -2-10- 6 19- 2-11-------------Webs------------- Wind -Force Resistance System.
M -N 0.05 167 T Wind Speed: 140 mph
psf-Ld Dead Live N -H 0.70 2796 C Mean Roof Height: 20-0
TC 15.0 20.0 H -B 0.29. 601 T Exposure Category: C
BC 5.0 0.0 O -B 0.02 109 T Occupancy Factor : 1.00
TCiBC 20.0 20.0 O -C 0.24 756 T Building Type: Enclosed
Total 40.0 Spacing 24.0^ I -C 0.03 210 C Zone location: Exterior
Lumber Duration Factor 1.25 I -D 0.04 191 T TC Dead Load : 9.0 psf
Plate Duration Factor 1.25 D -G 0.50 2013 C BC Dead Load : 3.0 psf
TC lb-1.00 F�1.00 Ft-1.00 Max comp. force 4315 Lbs
BC Fb-1.00 Fc=1.00 Ft=1.00 TL Defl -1.17" in I -M L/197 Max tone. force 4296 Lbs
LL Defl -0.47^ in I -M L/489 Connector Plate Fabrication
Total Load Reactions (Lbs) LL Cant 0.0511 in G -F L/539 Tolerance - 2�%11111 Millll
Jt Down Uplift Horiz- DL Defl -0.45^ at M L/511 This truss is%11bdor l/l
A 913 667 U 51 R Hz: Disp LL DL TL creep fac?<b�PI�.5 - wbA'q
G 1010 932 U 11 R it G 0.08^ 0.12" 0.19" is used go fipp�,
Shear // Grain in C -D 0.65 load d�1R bn,� J�''��j�Y
Jt Beg Size Required
A 16.9"-50^-to- -33^ Plates For each ply each Pace. - 99360
G 8.0" 1.5^ Plate - MT20 20 Ga, Gross Area " * :•
Plate - 14TBH 18 Ga, Gross Area
LC$ 1 Standard Loading Jt Type Plt Size I Y JSI •ram
Dur Fetre - Lbr 1.25 Plt 1.25 N MT20 4.Ox 4.0 1.5 Ctr 0.82
if - Dead Live* From To B MT20 7.Ox 8.0-0.5-0.9 0.83 i S ATE
TC V 30 40 -4.3' 19.2' D MT20 4.Ox 6.0 0.5-0.1 0.88 i 0�
BC V 10 0 0.0' 19.21 H MT20 5.Ox 8.0-0.5-0.9 0.93 '•'c( pQ:• ���
TC V 20 0 -4.3' 0.0. G MT20 4.Ox 6.0-0.5 Ctr 0.83 �R 1
Plus 6 Wind Load Case(s) REVIEWED BY: 1111111111
; ����,
Plus 1 UBC LL Load CaBe(9) MiTek Industries, Inc. 11
Plus 1 DL Load Cases) 6904 Parke East Blvd.
Tampa, FL 33610
Checked for NonConcurrent 200 FL Cert. 6634
Lba Moving Point Load applied REFER TO ONLINE PLUS GENERAL
at Panel Points and Mid -panel NOTES AND SYMBOLS SHEET FOR
on BC ADDITIONAL SPECIFICATIONS. JUDO 1,2011
ruo..w.•+nrw.hw uew,s+ma.vm+v..Y.,+un m+cw,..u... P^.w w+,m++•ncaw o..�+
Job
Mark
Quan Type Span
P1-H1
Left
OH Right OH
Engineering
22443-22444
A16G
I 1*2P Sp 110715
2.949
0
0
#22443-44 - MEL-RY - MORADI
8o 11-10
8o 3-11
TCI
12-6-12
1
5-4-7 I
Sx5
1.25
3J4
8
-T
x4
6.6 X
12.949
F
1-7-8
3x3
A
C
I
8
2.4
3.3
Cant:1- 0- 6
w:loeoe
w:eoo
R:1121
R:1200
U: 982
U:1052
BC 6-3-4
iL
11-7-1
ALL PLATES ARE MT2020
Scale: 0.34T' = 1'
Online Plus -- Version 28.0.006
RUN DATE: 27-MAY-11
* 2-Ply Truss +
CSI -Size- ----Lumber----
TC 0.73 2x 6 SP-SS
-- 0.46 2x 4 SP-#2
H -C
BC 0.50 2x 4 3P-#2
WB 0.17 2x 4 SP43
8L 0.03 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. -4- 6-12 11- 7-15
BC Cont. -4- 6-12 11- 7-15
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.00 Fc--1.00 Ft=1.00
BC Fb=1.00 Fc=1.00 Ft=1.00
Total Load Reactions (Lbs)
it Down Uplift Horiz-
A 1122 982 U 37 A
C 1200 1053 U 6 A
it Brg Size Required
A 20.511 -74^-to- -54^
C 8.0" 1.5^
LC# 1 Standard Loading
Dur Petra - Lbr 1.25 Plt
plf - Dead Live* From
TC V
30
40
-6.3'
BC V
10
0
0.0.
TC V
20
20
-6.3'
TC V
8
10
0.0'
38
50
SC
TC
SC
0.0'
7.7'
7.7'
1.25
To
11.7'
11.7'
0.0'
roka
Plus 6 Wind Load Cases)
Plus 1 UBC LL Load Cases)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
MiTek® Online Plus-
Lbs Moving Point Load applied
at Penal Points and Mid -panel
on BC
t4embr CSI P Lbs Axl-CSI-Bnd
__________TOP Chords__________
A -A
0.03
9 T
0.00
0.03
A -F
0.73
128 T
0.00
0.73
F -K
0.20
3752 C
0.09
0.11
K -1
0.19
3690 C
0.09
0.10
J -B
0.07
2471 C
0.05
0.02
H -C
0.46
2528 C
0.15
0.31
--------Bottom
Chords ---------
F -I
0.95
3698 T
0.34
0.11
I -e
0.49
3698 T
0.34
0.15
H -C
0.50
2493 T
0.22
0.28
I -J 0.05 315 T
J -H 0.17 1453 C
H -B 0.09 605 T
----------- Sliders ____________
F -K 0.03 242 T
TL Defl -0. 68^ in F -I L/255
LL Defl -0.28" in F -I L/622
DL Defl -0.20" at Z L/879
Hz Diap LL DL TL
it C 0.05^ 0.07" 0.11"
Shear // Grain in A -F 0.38
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MTBH 18 Ga, Gross Area
it Type Plt size X Y JSI
F MT20 6.Ox 6.0 3.0 0.2 0.99
H MT20 S.OX 5.0 Ctr-0.5 0.46
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS•
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
2 COMPLETE TRUSSES REQUIRID.
Fasten together in staggered
pattern. (1/2" bolts -OR-
SD83 screws -DR- lOd nails
as each layer is -applied.)
----Spacing (In)----
RowsNails Screws Bolts
TC 1 12 24 0
BC 1 12 24 0
WE 1 8 8
This truss has been designed
for 20.0 paf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psF non -
concurrent LL on BC.
Wind Loads - ANBI / ASCE 7-05
Truss is designed as a Main
Wind -Force Assistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 ps£
SC Dead Load 3.0 paf
Max comp. force 3752 Lbs
Max tens. force 3698 Lbs
Connector Plate Fabrication
Tolerance = 205
This trues is designed For a
creep Factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
.5285 ST.LVCIE BLVD.
FORT PIERCE, FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33963
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, :FL 33071
2. !!lCAVTIONIII READ "BCSI-HL
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS..
2-THRACE. 3-BEARING BLOCK.
Online PIusT' O C^pyrlght MTekl) 1998-2011 Varsian 26.0.006 EnglneeMg-Porbak �01110:26:31 AM Pagel
Job Mark Quan Type Span Pl-HI Left OH Right OH I Engineering
22443-22444 _CJI 1 2 ENDJO 10000 3.203 0 0
1 ik'J94d9-dd - MF.T.-RV - MORADT
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.33 2x 4 SP-N2
BC 0.32 2x 4 SP-k2
Brace truss as follows:
O.C. From To
TO Cont. 0- 0- 0 1- 0- 0
BC Cont. 0- 0- 0 1- 0- 0
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc�-1.10 Ft-1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 737 R
B 240 64 U 737 R
Jt Erg Size Required
C 1.5" I.S.
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 U13C LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Mambr CSI P Lbs Axl-CSI-End
----------Top Chords ----------
A -B 0.33 768 T 0.01 0.32
--------Bottom Chords ---------
SO 3-14 NO 7-1
A 1-0-0
3.203
TA 2-16d toenails
7-1
2-16d toenails
Cant:10- 8
BC - -
1-0-0
MiTek® Online Plus -
A -C 0.32 736 C 0.00 0.32
LL Cant -0.03" in A -C L/368
DL Defl 0.00" at L/999
Shear // Grain in A -B 0.28
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TBH 18 Ga, Grose Area
Jt Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL.
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Tresses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBc2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Scale: 1.088" = i'
Building Type: Enclosed
Zone location: Exterior
TO Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 736 Lbs
Me, tens. force 768 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.OEB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !IICAUTION!1! HEAD "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
OMne PNs"' O CopyiigM MTek®10ge-2011 Version 29.0.006 Englneedng- PoNsit 6Rn0111 V.26.38 AM Pagel
son Mark Quan Type Span Pl-HI Left OH Right OH Engineering
22443-22444 �CJ3 2 MON4 30000 3.203 0 0
#2� 2443-44 - MEL-RY - MORADI
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size- ----Lumber----
TC 0.47 2x 4 SP-#2
BC 0.33 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TO Cont. 0- 0- D 3- 0- 0
BC Cont. 0- 0- 0 3- 0- 0
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TO Fb-1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
'Total Load Reactions (Lbs)
it Down Uplift Horiz-
D 576 305 U 69 R
C 44 79 G
B 28 177 G 40 R
G - Gravity Uplift
it Brg Size Required
D 8.0" 1.5"
C 3.5" 1.5''
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CHI P Lbs Axl-CSI-Bnd
NO 3-14 NO 1-0-3
TCJ 3-0-0 1
4x4
Cant:l- 0- 0
7
W:800
R: 575
U: 304
BC 1-8-0 1- -0
A-- 3-0-0
ALL PLATES ARE MT2020
MiTek® Online Plus-
---------- Top Chords ----------
A -D 0.47 89 T 0.01 0.46
D -B 0.46 51 C 0.00 0.46
--------Bottom Chords ---------
* -D 0.33 0 T 0.00 0.33
D -C 0.20 0 T 0.00 0.20
TL Def1 -0.01" in D -C L/925
LL Defl -0.01" in D -C L/999
DL Defl 0.00" at L/999
-Hz Disp LL DL TL
it C 0.02" 0.00" 0.02"
Shear // Grain in D -D 0.45
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TSH 18 Ga. Gross Area
it Type Plt Size X Y TSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent: LL on BC.
Wind Loads - ANSI / ASCE 7-05
2-16d toenails
2-16d toenails
Scale: 0.648"= V
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 51 Lbs
Max tens. force 89 Lbs
Connector Plate Fabrication
Tolerance = 20%
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SRASHOUA,
P.EAEB5251 6 19554
1908 NW 122 AVE.
CORAL SPRINGS, FL 33071
2. 111 CAUTION! 11 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TERACE. 3-BEARING BLOCK.
OnMe Plus^ 0 Copynght MTek91996-2011 Version 28.0.008 Engineenng -Porten 6=011 1028.38 AM Page 1
Job Mark Quan Type Span Pi-Hl Left OH Right OH Engineering
22443-22944 ^ cis 2 MON4 50000 3.203 0 0
1i22443-44 - MEL-RY - MORADI
HO 3-14 HO 1-4-9
TCI 5-0-0
T 3.203�
2-16d toenails
1-7-14
3-5C 2.4
1 A
>-x C 2-16d toenails
D.
1
4.4
Cant:1- 0- 01
w:900
R: 442
U: 293
eC 1-8-0
6
ALL PLATES ARE MT2020
Scale: 0.639" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 01-JM-11
CHI -Size- ----Lumber----
TC 0.42 2x 4 SP-R2
HC 0.35 2x 4 SP-$2
Brace truss as follows:
O.C. From To
TO Cont. 0- 0- 0 5- 0- 0
BC Cont. 0- 0- 0 5- 0- 0
psf-Ld Dead Live
TO 15.0 20.0
HC 5.0 0.0
TC+HC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TO Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc-1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
D 442 294 U 116 R
C 46 26 G
B 97 100 U 68 R
G = Gravity Uplift
it Brg Size Required
D 8.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
MiTek4D Online Plus-
---------- Top Chords ----------
* -D 0.42 81 T 0.01 D.41
D -H 0.41 47 T 0.00 0.41
--------Bottom Chords ---------
* -D 0.35 0 T 0.00 0.35
D -C 0.26 0 T 0.00 0.26
TL Defl -0.02" in D -C L/999
LL Defl -0.02" in D -C L/999
DL Defl 0.00" at L/999
Hz Disp LL DL TL
it C 0.03" 0.00" 0.03"
Shear // Grain in D -D 0.40
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MTSH 18 Ga. Gross Area
it Type Plt Size R Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TO Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp, force 33 Lbs
Max tens. force 81 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcsaft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.EAEB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 11lCAUTION!11 READ "SCSI-H1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus"' OCoppl9nt MOeM I99&2011 Version 29.0.006 Eegime"- Pomalt 6fM011 1028:39AM Pagel
Job Mark Quan Type Span Pi -HI Left OH Right OH Engineering
22443-22444 -CJ7 1 1 MON4 70215 3.101 0 0
#22443-44 - MEL-RY - MORADI
3-13
HD
B
T3.10172-2-4
5-5C
1 zx4
A
C
.5 684
D
4x4
Cant:l- 0- 6
7
W:804
R: 419
U: 323
BC -- --
8 - -
ALL PLATES ARE Me2020
2-16d toenails
2-16d toenails
a
MSTek® Online Plus -
Online Plus -- Version 28.0.006
A -D 0.35 73 T 0.01 0.34
Wind -Force Resistance System.
RUN DATE: O1-,TUN-11
D -B 0.41 63 C 0.00 0.41
Wind Speed: 140 mph
--------Bottom Chords---------
Mean Roof Height: 20-0
CSI -Size- ----Lumber----
A -D 0.23 0 T 0.00 0.23
Exposure Category: C
TO 0.41 2x 4 SP-#2
D -C 0.18 0 T 0.00 0.lB
Occupancy Factor : 1.00
HC 0.23 2x 4 SP-#2
Building Type: Enclosed
TL Defl -0.09" in D -C L/699
Zone location: Exterior
Brace trues as follows:
LL Defl 0.05- in D -C L/999
TC Dead Load : 9.0 psf
O.C. From To
DL Defl 0.001, at L/999
BC Dead Load : 3.0 psf
TC Cont. 0- 0- 0 7- 2-15
Hz Disp LL DL TL
Max comp. force 63 Lbs
BC Cont. 0- 0- 0 7- 2-15
it C 0.01" 0.01" 0.02"
Max tens. force 73 Lbs
Shear // Grain in D -D 0.37
Connector Plate Fabrication
psf-Ld Dead Live
Tolerance = 20%
TO 15.0 20.0
Plates for each ply each face.
This truss is designed for a
BC 5.0 0.0
Plate - MT20 20 Ga, Gross Area
creep factor of 1.5 which
TC+BC 20.0 20.0
Plate - MT8H 18 Ga, Grose Area
is used to calculate total
Total 40.0 Spacing 24.0^
it Type Plt Size X Y JSI
load deflection.
Lumber Duration Factor 1.25
FABRICATOR NOTES:
Plate Duration Factor 1.25
REFER TO ONLINE PLUS GENERAL
1. EAST COAST TRUSS
TC Fb=1.15 Fc=1.10 Ft-1.10
NOTES AND SYMBOLS SHEET FOR
5285 ST.LUCIE BLVD.
BC Fb=1.10 FC=1.10 Ft=1.10
ADDITIONAL SPECIFICATIONS.
FORT PIERCE,FL 34946
Total Load Reactions (Lbs)
For proper installation of
S. Salim Cerci, P.E.
it Down Uplift Horiz-
toe -nails, refer to the 2005
5407 Wellcraft Dr.
D 420 324 U 164 R
National Design Specification
Greenacres, FL.33463
C 87
(LIDS) for Wood Construction
B 188 198 U 98 R
MAURICE A. SHASHOUA,
NOTES:
P.E.#EB5251 6 19554
it Brg Size Required
Trusses Manufactured by:
1908 NW 112 AVE.
D 8.2" 1.Se
East Coast Truss
CORAL SPRINGS, FL 33071
' C 3.5" 1.5..
Analysis Conforms To:
2. 111CAUTION111 HEAD 'SCSI-B1
B 1.5., I.S.
FBC2007
SUMMARY SHEET" BEFORE
TPI 2002
HANDLING , INSTALLING 6
Plus 5 Wind Load Case(s)
This trues has been designed
BRACING TRUSSES.
Plus 1 UBC LL Load Case(a)
for 20.0 psf LL on the B.C.
3. SEE ATTACHED DETAIL SHEET
Plus 1 DL Load Case(s)
in areas where a rectangle
FOR: 1-JACK NAILS.
3- 6- 0 tall by
2-TBRACE. 3-BEARING BLOCK.
Checked for NonConcurrent 200
2- 0- 0 wide
Lbs Moving Point Load applied
will fit between the H.C.
at Panel Points and Mid -panel
and any other member.
on BC
Design checked for 10 psf non -
concurrent LL on BC.
Membr CSI P Lbs Axl-CSI-Bnd
Wind Loads - ANSI / ASCE 7-05
----------Top Chords----------
Truss is designed as a Main
Online Plusw O Copyright MHek®199652011 Vemlon 28.0.008 Engineering-PorWt 6=0111028:39 AM Page 1
Job Nark Quan Type Span PI -Hi Left OH Right OH Engineering
2244J-22444 _CJA I 1 MON4 61102 3.203 0 0
22443-44 - MEL-RY - MORMI
ft0 3-14 HO 1-8-13
TC� 6-11-2 1
H
T3.2037 2-16d toenails
2-2-1
5-4C
1 2x4
A
C 2-16d toenails
I1
D
4.4
Cant:!- 0- 0
7
W:800
R: 439
U: 333
HC -- --
8 011 2
ALL PLATES ARE MT2020
Scale: 0.528" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size ------ Lumber----
TC 0.42 2x 4 SP-M2
BC 0.33 2x 4 SP-42
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 6-11- 2
BC Cont. 0- 0- 0 6-11- 2
pef-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Eb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
D 439 334 U 162 R
C 77
H 166 176 U 96 R
it Brg Size Required
D 8.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrant 200
Lbs Moving Point Load applied
at Panel Pointe and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords----------
MSTekS Online Plus -
A -D
0.42
79 T 0.01
0.41
D -B
0.41
62 T 0.00
0.41
--------Bottom Chords ---------
A -D
0.33
0 T 0.00
0.33
D -C
0.25
0 T 0.00
0.25
TL Defl
-0.06" in D -C
L/999
LL Defl
0.05" in D -C
L/999
DL Defl
0.00" at
L/999
Rz Disp
LL DL
TL
it C
0.04" 0.01--
0.03"
Shear //
Grain in D -D
0.39
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT6H 18 Ga, Gross Area
it Type Plt Size R Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
Forproper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Tress
Analysis Conforms To:
FBC2007
TPI 2002
This trues has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for SO psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 58Lbs
Max tens. force 79 Lbe
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.4EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Onl'me Plus`+O Copydgh!MTek®1996-2011 Vemlon 2&0.006 EnglneeMg-PaN t 8n20111026.40 AM Pages
Jon Nark Quan Type Span Pi -Hi Left OH Right OH Engineering
22443-22444 -CJB 1 1 MON4 50914 3.203 0 0
iF22443-44 - MEL-RY - MORADI
HO 3-i4 HO 1-6-5
TCI 5-9-14 �
T3.203I 7_ 2-16d toenails
-8
4-3C
1 2x4
A
C 2-16d toenails
D
4.4
A
Cant:l- 0- 0
W:800
R: 436
U: 309
Sc - - - -
v 14
ALL PLATES ARE MT2020
Scale: 0.62&1= 1'
MiTekO Online Plus -
Online Plus -- Version 28.0.006
----------Top Chords----------
Truss is designed as a Main
RUN DATE: O1-JUN-11
A -D 0.42 79 T 0.01 0.41
Wind -Force Resistance System.
D -B 0.41 53 T 0.00 0.41
Wind Speed: 140 mph
CSI -Size- ----Lumber----
--------Bottom Chords---------
Mean Roof Height: 20-0
TC 0.42 2x 4 SP-N2
A -D 0.34 0 T 0.00 0.34
Exposure Category: C
BC 0.34 2x 4 3P42
D -C 0.26 0 T 0.00 0.26
Occupancy Factor : 1.00
Building Type: Enclosed
Brace trues as follows:
TL Defl -0.03" in D -C L/999
Zone location: Exterior
O.C. From To
LL Defl 0.03" in D -C L/999
TC Dead Load : 9.0 psf
TC Cont. 0- 0- 0 5- 9-14
DL Defl 0.00" at L/999
BC Dead Load : 3.0 psf
BC Cont. 0- 0- 0 5- 9-14
He Disp LL DL TL
Max comp. force 44 Lbe
it C 0.03" 0.00" 0.03"
Max tens. force 79 Lbs
psf-Ld Dead Live
Shear // Grain in D -D 0.40
Connector Plate Fabrication
TC 15.0 20.0
Tolerance - 20%
BC 5.0 0.0
Plates for each ply each face.
This trues is designed for a
TC+BC 20.0 20.0
Plate - MT20 20 Ga, Gross Area
creep factor of 1.5 which
Total 40.0 Spacing 24.0"
Plate - MTSH 18 Ga. Grose Area
is used to calculate total
Lumber Duration Factor 1.25
it Type Plt Size X Y JSI
load deflection.
Plate Duration Factor 1.25
FABRICATOR NOTES:
TO Fb=1.15 Fc=1.10 Ft=1.10
REFER TO ONLINE PLUS GENERAL
1. EAST COAST TRUSS
BC Fb=-1.10 Fc=1.10 Ft=1.10
NOTES AND SYMBOLS SHEET FOR
5285 ST.LUCIE BLVD.
ADDITIONAL SPECIFICATIONS.
FORT PIERCE,FL 34946
Total Load Reactions (Lbs)
it Dawn Uplift Horiz-
For proper installation of
S. Selim Cerci, P.E.
D 436 309 U 136 R
toe -nails, refer to the 2005
5407 Wellcraft Dr.
C 60 13 G
National Design Specification
Greenacres, FL.33463
B 128 134 U 80 R
(NDS) for Wood Construction
G = Gravity Uplift
MAURICE A. SHASHOUA,
NOTES:
P.EAEB5251 6 19554
it erg Size Required
Trusses Manufactured by:
1908 NW 112 AVE.
• D 8.0" 1.5"
East Coast Truss
CORAL SPRINGS, FL 33071
C 3.5" 1.5"
Analysis Conformal To:
2. 111CAUTION111 READ "SCSI-BS
H 1.5" 1.5"
FBC2007
SUMMARY SHEET" BEFORE
TPI 2002
HANDLING , INSTALLING 6
" Plus 5 Wind Load Case(s)
This truss has been designed
BRACING TRUSSES.
Plus 1 UBC LL Load Case(s)
for 20.0 pef LL on the H.C.
3. SEE ATTACHED DETAIL SHEET
Plus 1 DL Load Case(s)
in areas where a rectangle
FOR: 1-JACK NAILS.
3- 6- 0 tall by
2-TBRACE. 3-HEARING BLOCK.
Checked for NonConcurrent 200
2- 0- 0 wide
Lbs Moving Point Load applied
will fit between the B.C.
at Panel Points and Mid -panel
and any other member.
on BC
Design checked for SO psf non -
concurrent LL on BC.
Membr CSI P Lbs Axl-CSI-Bad
Wind Loads - ANSI / ASCE 7-05
Online Plus"' O Copynghl MHek01996-2011 Vemlon 26.0.006 E:gineeMg- PoNail 6W011 10:28:40 AM Pagel
JRn Mark Quan Type Span PI -HI Left OH Right OH Engineering
22443.-22444 _CJC 1 MON4 40810 3.203 0 0
#22443-44 - MEL-RY - MORADI
SO 3-14 HO 1-3-15
TC1 4-8-10
T 3.203�
2-16d toenaila
1-7-0
3-1C 2x4
1A
2-16d toenails
D
4.4
Cant:l- 0-
W:800
R: 446
U: 289
ALL PLATES ARE MT2020
Scale: 0.699" = l'
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size- ----Lumber----
TC 0.42 2x 4 SP-02
EC 0.35 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 4- 8-10
BC Cont. 0- 0- 0 4- 8-10
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft-1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
D 447 290 U 110 R
C 42 31 G
B 86 87 U 64 R
G = Gravity Uplift
it erg Size Required
D 8.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(e)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
MiTekO Online Plus-
----------Top Chords----------
A -D 0.42 81 T 0.01 0.41
D -B 0.41 45 T 0.00 0.41
--------Bottom Chords ---------
* -D 0.35 0 T 0.00 0.35
D -C 0.26 0 T 0.00 0.26
TL Defl -0.02" in D -C L/999
LL Defl -0.02" in D -C L/999
DL Defl 0.00" at L/999
Hz Disp LL DL TL
it C 0.03" 0.00" 0.03"
Shear // Grain in D -D 0.41
Plates for each ply each face.
Plate - MT20 20 Ga. Gross Area
Plate - MT8H 18 Ga, Gross Area
it Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 30 Lbs
Max tens. force 81 Lbs
Connector Plate Fabrication
Tolerance = 209,
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIB BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greanacres, PL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 4 19554
1908 HW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION!1! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING S
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
On[418 Plus- 000py,Ighl MUek®19984011 Vemnn 28.0.008 Englneedng-Pw aft 6=01110:28:41 AM Pagel
Job
22443.-22444
I Mark
_CJD
I Quan Type Span
1 MON4 40406
Pl-Hl Left OH Right OH
2.852 0 0
Engineering
22443-44 - MEL-RY - MORADI
RO 3-13
NO 1-211
TC�
4-4-6
T
2.852
2-16d toenails
1-4-4
2-3C 2x4
A
r' a.
2-16d toenails
0.8905
D
4.4
Cant:1- 1- 8 .
W:900
R: 430
U: 275
HC
-10- -5-9
ra
ALL PLATES ARE W2020
Scale: 0.695" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size- ----Lumber----
TC 0.35 2x 4 SP-#2
BC 0.31 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 4- 4- 6
BC Cont. 0- 0- 0 4- 4- 6
paf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC#BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Pb=1.15 Fc=1.10 Ft=1.10
BC Fb-1.10 Fe1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Hor:Lz-
D 430 275 U 90 R
C 42 34 G
B 83 82 U 54 R
G = Gravity Uplift
it Brg Size Required
D 9.0" 1.5"
C 3.5" 1.5"
e 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 DEC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrant 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
MiTekO Online Plus-
----------Top Chords----------
- -D 0.35 73 T 0.01 0.34
D -B 0.34 38 T 0.00 0.34
--------Bottom Chords ---------
* -D 0.31 0 T 0.00 0.31
D -C 0.21 0 T 0.00 0.21
TL Defl -0.02" in D -C L/999
LL Defl -0.01" in D -C L/999
DL De£1 0.00" at L/999
Hz Disp LL DL TL
it C 0.02" 0.00" 0.02"
Shear // Grain in D -D 0.40
Plates for each ply each face.
Plate - MT20 20 Ga. Gross Area
Plate - MISS 18 Ga, Gross Area
it Type Pit Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NMS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This trues has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 paf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-OS
Trues is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp. force 25 Lbs
Max tens. force 73 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 11!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLACK.
OnMo Plus"'OCopyright PAiTek®1g96-2011Version28.0.W8EnginaeMg-Pa ft 6=0111028:42AM Paga1
Job Mark Quan Type Span PI -HI Left OH Right OH I Engineering
2244.E-22444 ^-CJE 1 2 MON4 30000 3.203 0 0
I 099dd4-dd - MF.T.-RV - MORAOT
SO 3-14 SO 1-0-3
TC1 3-0-0 1
Online Plus -- Version 28.0.006
RUN DATE: 01-OUN-11
CSI -Size- ----Lumber----
TC 0.47 2x 4 SP-#2
BC 0.33 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TC Cont. -0- 0- 0 3- 0-'0
BC Cont. 0- 0- 0 3- 0- 0
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC F1--1.15 Fc=1.10 FtP1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
D 576 305 U 69 R
C 44 79 G
B 28 177 G 40 R
G = Gravity Uplift
Jt Brg Size Required
D 8.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5..
Plus 5 Wind Load Casa(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Cases)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Mambr CSI P Lbs Axl-CSI-Bnd
D
4x4
Cant:l- 0- 0 7
W:800
R: 575
U: 304
3-0-0
ALL PLATES ARE MT2020
MiTek® Online Plus-
---------- Top Chords ----------
A -D 0.47 89 T 0.01 0.46
D -B 0.46 51 C 0.00 0.46
--------Bottom Chords ---------
* -D 0.33 0 T 0.00 0.33
D -C 0.20 0 T 0.00 0.20
TL Defl -0.01" in D -C L/925
LL Defl -0.01" in D -C L/999
DL Defl 0.00" at L/999
Hz Disp LL DL TL
it C 0.02" 0.00" 0.02"
Shear // Grain in D -D 0.45
Plates for each ply each face.
Plate - MT20 20 Ga, Grose Area
Plate - MT8H 18 Go, Gross Area
Jt Type Plt Size X Y JBI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
2-16d toenails
2-16d toenails
Scale: 0.800" = 1'
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
BC Dead Load 3.0 psf
Max comp. force 51 Lbs
Max tens. force 89 Lbs
Connector Plate Fabrication
Tolerance = 2096
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellaraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION111 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
Online Plus^' 0 Coppighl MReM 1996-2011 Venaon 28.0.006 EigNesmg- Pa R 6=0111028:42 AM Pagel
Job Mark Quan Type Span Pl-HI Left OH Right OH Engineering
22443-22444 _CJF 1 1 ENDJO 30004 3.203 0 0
#22443-44 - MEL-RY - MORADI
HO 3-14 HO 1-1-9
TC, 3-0-4
3.203�
T2-16d toenails
1-1_g 2x1
1 A
2-16d toenails
Cant:l- 0- 0
W:300
R: 393
U: 203
HC 3-0-
v -4 A
ALL PLATES ARE MT2020
Scale: 0.799" = T
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size- ---- Lumber----
TC 0.20 2x 4 SP42
BC 0.20 2x 4 SP42
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 3- 0-
BC Cont. 0- 0- 0 3- 0-
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+HC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=1.10 Ft-1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
A 394 203 U 69 R
C 222 45 G
e 59 59 U 40 R
G = Gravity Uplift
it Erg Size Required
A 3.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Cases)
Checked for NonConcnrrent 200
Lbs Moving Point Load applied
at Penal Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-end
MSTek® Online Plus'
__________Top Chords _-________
A -B 0.20 27 T 0.00 0.20
--------Bottom Chords ---------
A -C 0.20 0 T 0.00 0.20
TL Defl 0.00" in A -C L/999
LL Defl 0.00" in A -C L/999
DL Defl 0.00" at L/999
Shear // Grain in A -C 0.22
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TBH 18 Ga, Gross Area
it Type Plt Size X Y USI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This trues has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
BC Dead Load 3.0 pef
Max comp. force 20 Lbs
Max tens, force 78 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
111CAUTION111 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
OMns Plus"' OCopyrigM MTek®1998-2011 Version 28.0.008 Engineering -P^Nail 6=011 10:2a:43 AM Pagel
Job Mark Quan Type Span PI -Hi Left OH Right OH Engineering
22443-22444 _CJG 1 1 ENDJO 20201 3.203 0 0
1422443-44 - MEL-RY - MORADI
HO 3-14 SO 10-13
TC� 2-2-1 �
3.203�
T 2x4
10-13 A
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size- ----Lumber----
TC 0.21 2x 4 SP-#2
BC 0.20 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 2- 2- 1
HC Cont. 0- 0- 0 2- 2- 1
psf-Ld Dead Live
TO 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=-1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Boriz-
A 466 205 U 49 R
a 223 93 G
B 22 B6 G 28 R
G = Gravity Uplift
Jt erg Size Required
A 3.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
F
Cant:1- 0- D
W:300
R: 465
U: 205
BC - -
a 2-2'-1
ALL PLATES ARE MT2020
2-16d toenaila
2-16d toenails
MiTek® Online Plus-
---------- Top Chords ----------
A -B 0.21 26 C 0.00 0.21
--------Bottom Chords ---------
A -C 0.20 0 T 0.00 0.20
TL Defl 0.00" in A -C L/999
LL Defl 0.00" in A -C L/999
DL Defl 0.00" at L/999
Shear // Grain in A -B 0.15
Plates for each ply each face.
Plate -MT20 20 Ga, Grose Area
Plate - 14TBH 18 Ga. Gross Area
Jt Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, safer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 pef LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Scale: 0.793" = 1'
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TO Dead Load 9.0 pe£
BC Dead Load 3.0 psf
Max comp. force 26 Lbs
Max tens. force 88 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TERACE. 3-HEARING BLOCK.
OnOne Plus' 0 Copyright MRek%) 1996.2011 Version 28.0.006 Engineering -Portrait 6=01110:26:43 AM Page 1
Job
22443-22444
Mark
EJ7
Quan
1 7
Type Span P1-H1 Left OH
MON4 70000 3.203 0
Right OH
0
Engineering
#22443-44 - MEL-RY - MORADI
Ho 3-14
RO 1-9-0
TCI
7-0-0
B
T3.203
2-16d toenails
2-2-5
5-5C
1
2.4
A
C
2-16d toenails
I1
D
#4x4
Cant:1- 0- 0
W:B00
R: 440
U: 335
BC 1-0-0
-
ALL PLATES ARE MT2020, # = PLATE SELECTED IN PLATE MONITOR
Scale: 0.527" = T
Online Plus -- Version 28.0.006
RUN DATE: 01-UM-11
CHI -Size-
TC 0.43 2x 4 SP-#2
BC 0.33 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 7- 0- 0
BC Cont. '0- 0- 0 7- 0- 0
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fr-1.10 Ft=1.10
BC Fb=1.10 Fc=-1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
D 440 336 U 163 R
C 78
B 168 278 U 97 R
Jt Erg Size Required
D 8.0" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(B)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Mambr CHI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
MiTekO Online P1us-
A -D
0.43
79 T 0.01
0.42
D -B
0.42
63 T 0.00
0.42
--------Bottom
Chords ---------
* -D
0.33.
0 T 0.00
0.33
D -C
0.25
0 T 0.00
0.25
TL Defl -0.06" in D -C L/967
LL Defl 0.05" in D -C L/999
DL Defl 0.00" at L/999
Hz D1sp LL DL TL
Jt C 0.04" 0.01" 0.03"
Shear // Grain in D -D 0.40
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 20 Ga, Gross Area
Jt Type Plt Size X Y JSI
D# MT20 4.Ox 4.0-0.2 0.6 0.37
# = Plate Monitor used
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
NOTE: USER MODIFIED PLATES
This design may have plates
selected through a plate
monitor.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load 9.0 psf
BC Dead Load 3.0 psf
Max comp. force 58 Lbs
Max tens. force 79 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Carci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, EL 33071
2. !!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
OiPne Plus^' 0 Copyright MITek01996-2011 Version 28.0.005 Engineering - Ported 6l82011 ln29:43 AM Pagel
Jab Mark I Quan Type Span Pl-Hl Left OH Right OH Engineering
22443-22444 EJ28 1 ENDJO 20809 2.949 0 0
HO 3-21 HO 11-11
4 2-8-9 -�
2.9491
T
2x4
11-11 A
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size-
TC 0.13 2x 4 SP-#2
BC 0.15 2x 4 SP-#2
Brace truss as follows:
O.C. Fran To
TC Cont. 0- 0- 0 2- 8- 9
BC Cont. -0- 0- 0 2- 8- 9
pef-Ld Dead Live
TO 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft-1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 267 79 U 54 R
C 238 18 U
B 76 78 U 33 R
Jt Brg Size Required
A 3.9" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CHI P Lbs Axl-CSI-End
----------Top Chords ----------
W:314
R: 266
U: 78
HCII2-8-9
fs- 2-e-9 III
ALL PLATES ARE MT2020
MSTek® Online Plus^
A -B 0.13 22 C 0.00 0.13
--------Bottom Chords ---------
A -C 0.15 0 T 0.00 0.15
TL Defl -0.01" in A -C L/999
LL Defl -0.01" in A -C L/999
DL Defl 0.00" at L/999
Shear // Grain in A -C 0.17
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MIZE 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBc2007
TPI 2002
This truse has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 pef non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
2-16d toenails
2-16d toenails
Scale: 0.796" = V
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 psf
Max comp: force 22 Lbs
Max tens. force 21 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Gseenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 3 19554
2908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION M READ ^SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
OMne Plus- ®Capplght Miffek®1995-2011 Vemlan 28.0.006 Ergmeerin9 - PorNm 612R011 1028:" AM Pagel
rob Mark Quan Type Span P1-H1 Left OH Right OH Engineering
22443-22444 EJ36 1 ENDJO 30611 2.949 0 0
#22443-44 - MEL-RY - MORADI
HO 3-11 SO 1-2-3
TC1 3-6-11
2.949�
T2-16d toenails
1-2-3 2x4
1 A
2-16d toenails
W:314
R: 280
U: 103
BC -- 1
3-6-11
ALL PLATES ARE MT2020
Scale: 0.701 ° = V
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size- ----Lumber----
TC 0.17 2x 4 SP-82
BC 0.24 2x 4 SP-#2
Brace trues as follows:
O.C. From To
TC Cont. 0- 0- 0 3- 6-11
BC Cont. 0- 0- 0 3- 6-11
pef-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plats Duration Factor 1.25
TC Fb=1.15 F�1.10 Ft-1.10
BC F'b-1.10 F0=1.30 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 280 104 U 72 R
C 238 19 U
B 102 106 U 45 R
Jt erg Size Required
A 3.9" 1.5"
C 3.5" I.S.
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords----------
MiTek41 Online Plus -
A -B 0.17 30 C 0.00 0.17
--------Bottom Chords ---------
A -C 0.24 0 T 0.00 0.24
TL Defl -0.02" in A -C L/999
LL Dafl -0.01" in A -C L/999
DL Defl 0.00" at L/999
Shear // Grain in A -C 0.17
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(LIDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
BC Dead Load : 3.0 pef
Max comp. force 30 Lbs
Max terse, force 27 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcra£t Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.4EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION!!! READ 'SCSI-B1
SULII4ARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
ONina Plus"' O Copyright MTek®1g962017 Vemion 28.0.006 Engbeenng -PorMh 6/d4011 10R8:44 AM Pagel
Job Quan Type span pi -Hi Left OH Right OH Engineering
22443_22444 F._TMarkS2 1 ENDJO 50301 2.949 0 0
HO 3-11 HO 1-7-3
T2.949F
1-7-3
1 2x4
A
M
W:314
R: 311
U: 153
HCJ 5-3-1
a 5-3-1
ALL PLATES ARE MT2020
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CSI -Size-
TO 0.27 2x 4 SP-#2
HC 4.42 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TO Cont. 0- 0- 0 5- 3- 1
HC Cont. 0- 0- 0 5- 3- 1
psf-Ld Dead Live
TC 15.0 20.0
HC 5.0 0.0
TC+BC 20.0. 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TO Eb=1.15 Fr-1.10 Ft=1.10
HC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 311 154 U 109 R
C 244 23 U
e 155 162 U 67 R
Jt erg Size Required
A 3.9" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
Plus 5 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on HC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords----------
MiTek® Online Pluss
A -B 0.27 47 C 0.00 0.27
--------Bottom Chords ---------
A -C 0.42 0 T 0.00 0.42
TL -Defl -0.06" in A -C L/878
LL Defl -0.03" in A -C L/999
DL Defl 0.00" at L/999
Shear // Grain in A -B 0.18
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TBH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
This truss has been designed
for 20.0 psf LL on the B.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on EC.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
2-16d toenails
2-16d toenails
Scale: 0.639" = 1'
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TO Dead Load 9.0 psf
BC Dead Load 3.0 psf
Max comp. force 47 Lbs
Max tens. force 40 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellora£t Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 5 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
OnOne Plus"' O Copytl9ht MTek6l996-20N Vemlon 26.0.006 Egineenng-Pomeit 6=011 10:23.45 AM Pagel
Job Mark Quan Type Span PI-Hl Left OH Right OH Engineering
2244122444 1 EJSll 1 sP 51106 2.949 1-14 0
#22443-44 - MEL-RY - MORADI
HO 4-3 SO 1-2-2
a
N
TC t' I 1-4-12 13121 4-2-14 1
2.949F
1.25
T
4x4
�
B 3-16d toenails
2x4
1-2-2 A
1 2-16d toenails
W:1104
R: 437
U: 335
BC 5-11-5
tE
5-11-6
ALL PLATES ARE MT2020
Scale: 0.648" = V
Online Plus -- Version 28.0.006
RUN DATE: 01-JUN-11
CHI -Size- -Lumber----
TC 0.75 2x 4 SP-#2
Be 0.56 2x 4 SP-#2
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 5-11-
BC Cont. 0- 0- 0 5-11-
psf-Ld Dead Live
TC 15.0 20.0
Be 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.00 Fc=1.00 Ft=1.00
Be Fb=1.00 Fc=1.00 Ft=1.00
Total Load Reactions (Lbs)
it Down Uplift Horiz-
A 438 335 U 128 R
E 119 36 U
D 314 342 U 114 R
it Erg Size Required
A 11.2" 1.5"
E 3.5" 1.5"
D 1.5" 1.5"
LC# 1 Standard Loading
Dur Fctrs - Lbr 1.25 Plt 1.25
pl£ - Dead Live* From To
TC V 30 40 0.0' 5.9'
Be V 10 0 0.0' 5.9'
TC V 23 30 0.0' 5.9'
Be V 8 0 0.0' 5.9'
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Cases)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on Be
MiTek® Online Plus-
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
* -B 0.35 103 T 0.00 0.35
B -D 0.75 72 T 0.00 0.75
--------Bottom Chords ---------
A -E 0.56 0 T 0.00 0.56
TL De£1 -0.17" in B -E L/334
LL Defl -0.07" in H -E L/770
DL De£1 0.00" at L/999
Shear // Grain in B -D 0.38
Plates for each ply each face.
Plate - MT20 20 Go, Gross Area
Plate - MT8H 18 Gal Gross Area
it Type Plt Size R Y JSI
B MT20 4.Ox 4.0 Ctr-0.7 0.40
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
too -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
ON Loading
Soffit pef 2.0
This truss has been designed
for 20.0 ps£ LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the H.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on Be.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior -
TC Dead Load 9.0 pef
Be Dead Load 3.0 ps£
Max comp. force 73 Lbs
Max tens. force 103 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
!!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus'• 0 Copyright MOeIV 19962011 Version 29.0.006 Erg'neanng -Pomeft 6=011 10:28:46 AM Page 1
Job Mark Quan Type Span P1-H1 Left OH Right OH I Engineering
22443-22444 HJ7 I 1 MON4 91013 2.265 0 0
#22443-44 - MEL-RY - MORADI
NO 3-12 SO 1-8-14
'Cl9-10-13 I
B
T 2.265
2.4 3-16d toenails
E
2-2-3
5-5C
2x4
1 A
3-16d toenails
�0.7071 C
2x4
D
4.4
Cant:l- 5- 0
W:1105
R: 601
U: 588
BC2-5-1
a a" 13
ALL PLATES ARE MT2020
Scale: 0.486" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size-
TC 0.91 2x 4 SP-#1
BC 0.86 2x 4 SP-#2
WE 0.43 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 9-10-13
BC Cont. 0- 0- 0 9-10-13
psf-Ld Dead Live
TC 15.0 20.0
BC 5.0 0.0
TC+BC 20.0 20.0
Total 40.0 Spacing 24.0"
Lumber Duration Factor 1.25
Plate Duration Factor 1.25
TC Fb=1.00 Fc=-1.00 Ft-1.00
BC Fb=1.00 Fc 1.00 Ft=1.00
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
D 601 589 U 268 R
C 361 173 U
B 324 383 U 162 R
Jt Brg Size Required
D 11.3" 1.5"
C 3.5" 1.5"
B 1.5" 1.5"
MiTek® Online Plus -
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
A -E 0.91 1133 C 0.11 0.80
E -B 0.52 112 T 0.00 0.52
--------Bottom Chords ---------
A -D 0.75 1096 T 0.12 0.63
D -D 0.75 1182 C 0.12 0.63
D -C 0.86 1183 C 0.12 0.74
------------- Webs -------------
E -C 0.43 1194 T
TL Defl -0.17" in D -C L/511
LL Defl -0.12" in D -C L/735
DL Defl 0.00" at L/999
Hz Disp LL DL TL
Jt B 0.05" 0.01" 0.04"
Shear // Grain in D -D 0.75
Plates for each ply each face.
Plate - MT20 20 Ga, Grose Area
Plate - MT8H 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
For proper installation of
toe -nails, refer to the 2005
National Design Specification
(NDS) for Wood Construction
LCA
1 Standard Loading
Dar Fctxe - Lbr 1.25 Plt 1.25
NOTES:
plf
- Dead Live* From To
Trusses Manufactured by:
TC V
30 40 0.0' 9.9'
East Coast Truss
BC V
10 0 0.0' 9.9'
Analysis Conforms To:
TC V
-8 -10 0.0,
FBC2007
38 50 9.9'
TPI 2002
BC V
-3 0 0.0.
This truss has been designed
13 0 9.9'
for 20.0 paf LL on the H.C.
in areas where a rectangle
Plus
5 Wind Load Case(s)
3- 6- 0 tall by
Plus
1 UBC LL Load Case(&)
2- 0- 0 wide
Plus
1 DL Load Cases)
will fit between the B.C.
and any other member.
Checked for NonConcurrent 200
Design checked for 10 psf non-
Lbe Moving Point Load applied
concurrent LL on BC.
Online Phn" OCopynghl MRek®1998-2011Vmlon28.OAOa EngheeMg-Pomsil 6=01110:2&46AM Pagel
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Height: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TC Dead Load : 9.0 psf
EC Dead Load : 3.0 pef
Max comp. force 1183 Lbs
Max tens. force 1194 Me
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.11EB5251 S 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. M CAUTION M READ "SCSI-B1
SU[MARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Job Mark Quan Type Span Pl-HI Left OH Right OH Engineering
22443-22444 FGI I 1*2P FLAT 80715 10400 0 0
22443-44 - MEL-RY - MORADI
NO 1-4-0 NO 1-4-0
TC] 8-7-15
3x10 2x4 2x4 3x3
A H I J
4x6
H
T a
1-4-0
1WE 11
D u" C
3x4 G F E x4
5.6 3x3 Sx5
r__2- 4-109_10_�
W:508 W:615
R:3160 R: 3160
U:2327 U:2327
Sc
ALL PLATES ARE MT2020
Sale: 0.675" = V
Online Plus -- Ver.ion 28.0.006
RUN DATE: 26-MAY-11
eat++++++++++•a
+ 2-Ply True. +
CHI -Size- ----Lumber----
TC 0.81 2x 4 SP42
BC 0.68 2x 4 SP-SS
WB 0.69 2x 4 `SP-42
-- 0.32 2x 4 SP-43
D -A G -H F -I F -J
E-J C-B
Brace truss as follow.:
O.C. From To
TO Cont. 0- 0- 0 8- 7-15
BC Cont. 0- 0- 0 8- 7-15
psf-Ld Dead Live
TO 100 400
BC 5..0 0..0
TC+BC 150 40.0
Total 55..0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.00 Fc-1.00 Ft=1.00
BC Fb=1.00 Fc=1.00 Ft-1.00
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
D 3160 2327 U 76 R
C 3160 2327 U 76 R
Jt Brg Size Required
D 5.5" 1.9"
C 6.9" 1.9"
MSTek® Online P1us-
H -I
0.81
5393 C 0.09
0.72
I -J
0.64
5393 C 0.09
0.55
J -B
0.41
4791 C 0.07
0.34
--------Bottom
Chord ----------
* -G
0.19
56 T 0.00
0.19
G -F
0
5393 T 0.32
0.31
F -E
0..68 64
4791 T 0.28
0.36
E -C
0.06
56 T 0.00
O.Ofi
-------------
Webs _____--------
D -A
032
32BI C WindLd
A -G
0..69
6024 T
G -H
0.21
2142 C
F -I
0.08
898 C
F -J
013
672 T
E -J
0..21
2159 C
E -8
0.61
5352 T
C -B
0.30
3122 C WindLd
TL Defl -0.16" in F -E L/569
LL De£1 -0.10" in F -E L/885
DL De£1 0.00" at L/999
Shear // Grain in H -I 0.92
Plates for each ply each face.
Plate - MT20 20 Ga. Gross Area
Plate - MT8H 18 Ga, Grose Area
Jt Type Plt Site X Y JSI
A MT20 3.0.10.0 2.4-0.4 0.90
H MT20 2.Ox 4.0 Ctr 0.6 0.71
B MT20 4.Ox 6.0-1.4-0.6 0.91
G MT20 B.O. 6.0-1.5 Ctr 0.94
E MT20 S.Ox 5.0 1.5 Ctr 0.95
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
LCB 1 Standard Loading
Trusses Manufactured by:
Dur Purrs - Lb. 1.00 Plt 1.00
East Coast Truce
pl£ - Dead Live+ From To
Analysis Conforms To:
TO V 20 80 -0.0. 8.7-
MC2007
BC V 10 0 0.0' 8.7'
TPI 2002 '
TO V 83 220 0.0' 8.7'
2 COMPLETE TRUSSES REQUIRED.
TO V 87 231 0.01 8.7'
Fasten together in staggered
pattern. (1/21' bolts -OR-
Plus 6 Wind Load Case(s)
SDS3 acre we -OR- 10d nails
Plus 1 DEC LL Load Case (a)
as each layer is applied.)
Plus 1 DL Load Case(s)
----Spacing (In) ----
Rows Nails Screws Bolt.
Checked for NonConcurrent 200
TC 1 4 8 0
the Moving Point Load applied
BC 1 12 24 0
at Panel Points and Mid -panel
WB 1 8 8
on HC
Web Connection Exception --
Space screws or nails for the
Membr CSI P Lb. Axl-CSI-Bnd
following web --
____----_- Top Chords__________
A -G 0 4" o.c.
A -H 0.81 5393 C 0.09 0.72
E -B @ 4" ....
Online Plus- 0 Copydghl MHek01996-2011 Version 28.0.D08 Enginseh:g- Ported 6=11 102B:47 AM Page 1
This truss has been designed
for 20.0 p-£ LL on the H.C.
in areas where a rectangle
3- 6- 0 tall by
2- 0- 0 wide
will fit between the B.C.
and any other member.
Design checked for 10 psf non -
concurrent LL on BC.
Provide drainage to prevent
water pending.
This truss must be installed
as she.. It .snot be
installed upside-down.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140 mph
Mean Roof Haight: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TO
Dead Load 6.0 pee
BC Dead Load 3.0 ps£
Max comp, force 5393 Lb.
Max tens. force 6024 Lbs
Connector Plate Fabrication
Tolerance = 20%
This true. is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE, FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres. FL.33463
MAURICE A. SHASHOUA,
P.EAEB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
IIICAUTION111 READ •'BCSI-H1
SU ID Y SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Jab Mark Quan Type Span P1-H1 Left OH Right OH Engineering
22443r22444 FG2 1*2P FLAT 50007 10400 0 0
22443-44 - MEL-RY - MORADI
HO 1-4-0 HO 1-4-0
TCJ 5-0-7
2.4 2x4
G H
3x4 3.4
A B
T
1_4_0
TD C
2x4 P E ES x4
;p..£ 3.4 3x4 7
W:411 W:600
R:1887 R:1887.
U:1394 U:1394
BC
v' + .
ALL PLATES ARE MT2020
Scale: D.71V' = V
MSTek® Online Pluse,
Online Plus -- Version 28.0.006
Membr CSI P Lbs Axl-CSI-end
for 20.0 psf LL on the H.C.
RUN DATE: 26-MAY-11
----------Top Chords----------
in areas where a rectangle
*••:•••••••+•••
A -G 0.23 1841 C 0.01 0.22
3- 6- 0 tall by
• 2-Ply Truss •
G -H 0.16 2841 C 0.09 0.07
2- 0- 0 wide
•e••••••••••••e
H -H 0.23 1841 C 0.01 0.22
will fit between the B.C.
--------Bottom Chords---------
and any other member.
CSI -Size- ----Lumber----
D -F 0.10 56 T 0.00 0.10
_
Design Checked for 10 psf non-
TC 0.23 2x 4 SP-42
F -E 0.29 1841 T 0.21 0.08
concurrent LL on BC.
BC 0.29 2x 4 SP-N2
E -C 0.10 56 T 0.00 0.10
Provide drainage to prevent
WB 0.44 2x 4 SP-03
-------------Webs-------------
water ponding.
D -A 0.18 1839 C WindLd
This truss must be installed
Brace truss as follows:
A -F 0.44 2204 T
as shown. It cannot be
O.C. From To
F -G 0.12 1235 C
installed upside-down.
TC Cont. 0- 0- 0 5- 0- 7
E -H 0.12 1235 C
Wind Loads - ANSI / ASCE 7-05
BC Cont. 0- 0- 0 5- 0- 7
E -B 0.44 2204 T
Truss is designed as a Main
C -B 0.18 1839 C WindLd
Wind -Force Resistance System.
psf-Ld Dead Live
Wind Speed: 140 mph
TC 10.0 40.0
TL Defl -0.02" in F -E L/999
Mean Roof Height: 20-0
BC 5.0 0.0
LL Defl -0.01" in F -E L/999
Exposure Category: C
TC+BC 15.0 40.0
DL Defl 0.00" at L/999
Occupancy Factor : 1.00
Total 55.0 Spacing 24.0"
Shear // Grain in A -G 0.53
Building Type: Enclosed
Lumber Duration Factor 1.00
Zone location: Exterior
Plate Duration Factor 1.00
Plates for each ply each face.
TC Dead Load 6.0 psf
TC Fb=1.00 Fc=1.00 Ft--1.00
Plate - 24T20 20 Go, Gross Area
BC Dead Load 3.0 psf
BC Fb-1.00 Fc=1.00 Ft=1.00
Plate - MISS 18 Gal Gross Area
Max comp: force 1841 Lbs
Jt Type Plt Size X Y JSI
Max tens. force 2204 Lbs
Total Load Reactions (Lbs)
A MT20 3.Ox 4.0 0.4-0.3 0.90
Connector Plate Fabrication
Jt Down Uplift Horiz-
H MT20 3.Ox 4.0-0.4-0.3 0.90
Tolerance - 20%
D 1887 1394 U 76 R
F MT20 3.Ox 4.0-1.0 Ctr 0.85
This truss is designed for a
C 1887 1394 U 76 R
E MT20 3.Ox 4.0 1.0 Ctr 0.85
creep factor of 1.5 which
is used to calculate total
Jt Brg Size Required
REFER TO ONLINE PLUS GENERAL
load deflection.
D 4.7" 1.5"
NOTES AND SYMBOLS SHEET FOR
FABRICATOR NOTES:
C 6.0" 1.5"
ADDITIONAL SPECIFICATIONS.
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
LC4 1 Standard Loading
NOTES:
FORT PIERCE,FL 34946
Dur Fctrs - Lbr 1.00 Plt 1.00
Trusses Manufactured by:
plf - Dead Live* From To
East Coast Truss
S. Salim Cerci, P.E.
TC V 20 BO 0.0' 5.0'
Analysis Conforms To:
5407 Wellcraft Dr.
BC V 10 0 0.0. 5.0'
FSC2007
Greenacres, FL.33463
TC V 83 220 0.0. 5.0'
TPI 2002
TC V 92 245 0.0' 5.0'
2 COMPLETE TRUSSES REQUIRED.
MAURICE A. SHASHOUA,
Fasten together in staggered
P.E.4EH5251 6 19554
Plus 6 Wind Load Case(s)
pattern. (1/2" bolts -OR-
1908 NW 112 AVE.
Plus 1 UBC LL Load Case(s)
SDS3 screws -OR- 10d nails
CORAL SPRINGS, FL 33071
Plus 1 DL Load Case(s)
as each layer is applied.)
2. 1t!CAUTIONI I! READ "SCSI-BS
----Spacing (In)----
SUMMARY SHEET" BEFORE
Checked for NonConcurrent 200
Rows Nails Screws Bolts
HANDLING , INSTALLING 6
Lbs Moving Point Load applied
TC 1 4 7.5 0
BRACING TRUSSES.
at Panel Points and Mid -panel
BC 1 12 24 0
3. SEE ATTACHED DETAIL SHEET
on BC
wS 1 8 8
FOR: 1-JACK NAILS.
This truss has been designed
2-TBRACE. 3-HEARING BLOCK.
Onllne Plus^' 0 Copyright MITeM 1996-2011 Version 28.0.006 Engineadng -Pamit 6RR011 10:28:47 AM Page 1
Job Mark Quan Type Span Pl-Hl Left OH Right OH Engineering
22443-22444 FT23 1 1 Sp 101111 10400 0 0
#22443-44 - MEL-RY - MORADI
SO 1-0-0 HO 1-4-0
TC, 3-1-9 1 7-10-2
#4x8
c
2x4 3.3 3.3 3.4
i D K L M E
T 4x6
8
1-4-0
A P
2x4 G J I H x4
4.14 3x6 3.3 3x4
W:800 W:508
R: 747 R: 659
SC10-11-11
10-11-11
ALL PLATES ARE MT2020, # = PLATE SELECTED IN PLATE MONITOR
Scale: 0.54T' = V
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
CSI -Size- ----Lumber----
TC 0.34 2x 4 SP-#2
BC 0.59 2x 4 SP-#2
WE 0.79 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont: 0- 0- 0 10-11-11
BC Cont. 0- 0- 0 10-11-11
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.00 F�1.00 Ft=1.00
BC Fb=1.00 Fr-1.00 Ft--1.00
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 748
F 659
Jt Erg Size Required
A 8.0" 1.5"
F 5.5" 1.5"
LC# 1 Standard Loading
Dur Fctrs - Lbx 1.00 Plt 1.00
plf - Dead Live* From To
TC V 20 80 0.0' 11.0'
BC V 10 0 0.0' 11.0'
TC V 200 0 - 3.1' CL-LB
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
MiTek49 Online Plus-
M -E
0.10
975 C
0.01
0.09
--------Bottom
Chords ---------
A -G
0.38
0 T
0.00
0.38
G -J
0.59
1856 T
0.42
0.17
J -I
0.44
1556 T
0.22
0.22
I -H
0.35
975 T
0.14
0.21
H -F
0.21
0 T
0.00
0.21
A -B
0.13
709 C
B -G
0.79
1982 T
G -C
0.09
465 C
C -J
0.06
299 C
J -K
0.01
56 C
J -L
0.13
348 T
I -L
0.06
309 C
I -M
0.26
663 T
H -M
0.10
523 C
H -E
0.44
1114 T'
F -E
0.12
639 C
TL Defl -0.12" in G -J L/982
LL Defl -0.06" in G -J L/999
DL Defl -0.12" at G L/945
Shear // Grain in B -C 0.24
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TBH 20 Ga. Gross Area
Jt Type Plt Size X Y JSI
B MT20 4.Ox 6.0 1.0 Ctr 0.93
C# MT20 4.Ox 8.0-0.2-0.6 0.72
M MT20 3.Ox 3.0-0.5 Ctr 0.75
E MT20 3.Ox 4.0-0.5-0.2 0.91
G MT20 4.Oxl4.0-4.0 Ctr 1.00
I MT20 3.Ox 3.0 0.5 Ctr 0.75
B MT20 3.Ox 4.0 1.0 Ctr 0.85
# = Plate Monitor used
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
Checked for NonConcuxrent 200
NOTES:
Lbs Moving Point Load applied
Trusses Manufactured by:
at Panel Points and Mid -panel
East Coast Truss
on BC
Analysis Conforms To:
FBC2007
Membr CST P Lbs Axl-CSI-Bnd
TPI 2002
----------Top Chords----------
Design checked for 10 psf non-
e -C 0.34 1936 C 0.05 0.29
concurrent LL on BC.
C -K 0.16 1799 C 0.04 0.12
Provide drainage to prevent
K -L 0.14 1793 C 0.04 0.10
water ponding.
L -M 0.12 1556 C 0.03 0.09
This truss must be installed
Online Plus*' 0 Copyright MTek®18 2011 Version 28.0.M6 Engineering- Porimil SWD111a25:48 AM Pagel
as shown. It cannot be
installed upside-down.
NOTE: USER MODIFIED PLATES
This design may have plates
selected through a plate
monitor.
Max comp. force 1936 Lbs
Max tens, force 1982 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
52B5 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! BEAD 11BCSI-B1
SUMHhRY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
sob Marx Quan Type span Pl-Hl Left OH Right OH Engineering
22443-22444 FT24 1 sP 101115 10400 0 0
1-1199dd4-dd - MF.T.-RV - MORAnT
SO 1-0-0 SO 1-4-0
TO 3-11-12 1 7-0-3
5.6
C
T
1-4-0
A
2.4
I c s L
4.4 3x3 3.8 3x4
w:800 w:508
R: 733 R: 676
BC 1 -1 -15
L -10-11-15
ALL PLATES ARE MT2020
Scale: 0.54V' =1'
MiTek® Online Plus -
Online Plus -- Version 28.0.006
..
RUN DATE: 31-MAY-11
1"r CSI P Lbs Axl-CSI-Bnd
NOTES:
----------Top Chords----------
Trusses Manufactured by:
CSI -Size- ----Lumber----
B -J 0.18 1604 C 0.03 0.15
East Coast Truss
TC 0.21 2x 4 SP-#2
J -C 0.21 2192 C 0.06 0.15
Analysis Conforms To:
BC 0.60 2x 4 SP-#2
C -K 0.21 1785 C 0.04 0.17
FBC2007
WB 0.68 2x 4 SP-#3
K -M 0.14 1782 C 0.04 0.10
TPI 2002
M -E 0.14 1157 C 0.01 0.13
Design checked for 10 psf non -
Brace truss as follows:
--------Bottom Chords---------
concurrent LL on BC.
O.C. From To
A -I 0.24 0 T 0.00 0.24
Provide drainage to prevent
TO Cont. 0- 0- 0 10-11-15
I -G 0.52 2604 T 0.24 0.28
water ponding.
BC Cont. 0- 0- 0 10-11-15
G -H 0.60 2151 T 0.49 0.11
This truss must be installed
H -L 0.37 1157 T 0.16 0.21
as shown. It cannot be
psf-Ld Dead Live
L -F 0.25 0 T 0.00 0.25
installed upside-down.
TC 10.0 40.0
-------------Webs-------------
Max Comp. force 2192 Lbs
BC 5.0 0.0
A -B 0.13 696 C
Max tens. force 2151 Lbs
TC+BC 15.0 40.0
B -I 0.68 1703 T
Connector Plate Fabrication
Total 55.0 Spacing 24.0"
L -J 0.11 579 C
Tolerance = 20%
Lumber Duration Factor 1.00
J -G 0.24 614 T
This truss is designed for a
Plate Duration Factor 1.00
G -C 0.03 196 C
creep factor of 1.5 which
TC Fb-1.00 Fc,1.00 Ft=1.00
C -H 0.11 515 C
is used to calculate total
BC Fb=1.00 Fc=1.00 Ft--1.00
H -K 0.02 121 C
load deflection.
H -M 0.27 689 T
FABRICATOR NOTES:
Total Load Reactions (Lbs)
L -M 0.10 524 C
1. EAST COAST TRUSS
Jt Down Uplift Horiz-
L -E 0.51 1275 T
5285 ST.LUCIE BLVD.
A 733
F -E 0.12 654 C
FORT PIERCE,FL 34946
F 676
TL Defl -0.12" in G -H L/947
S. Salim Cerci, P.E.
Jt Erg Size Required
LL Defl -0.06" in G -H L/999
5407 Wellcraft Dr.
A 8.0" 1.5"
DL Defl -0.12" at G L/947
Greenacres, FL.33463
F -9.5" 1.5"
Shear // Grain in C -K 0.21
MAURICE A. SHASHOUA,
LC# 1 Standard Loading
Plates for each ply each face.
P.E.#EB5251 6 19554
Dur Fctra - Lbr 1.00 Plt 1.00
Plate - MT20 20 Ga, Gross Area
1908 NW 112 AVE.
plf - Dead Live* From To
Plate - 14TBH 18 Ga, Gross Area
CORAL SPRINGS, FL 33071
TC V 20 80 0.0' 11.0'
Jt Type Plt Size X Y JSI
2. 111CAUTION111 READ 11SCSI-B1
• BC V 10 0 0.01 11.0'
B MT20 4.Ox 4.0 1.0-0.2 0.97
SUMMARY SHEET" BEFORE
TC V 200 0 4.01 CL-LB
C MT20 5.Ox 6.0-0.5-0.6 0.86
HANDLING , INSTALLING 6
M MT20 3.Ox 3.0-0.5 Ctr 0.78
BRACING TRUSSES.
Plus 1 UBC LL Load Case(s)
E MT20 3.Ox 4.0-0.9-0.4 0.82
3. SEE ATTACHED DETAIL SHEET
Plus 1 DL Load Case(S)
I 14T20 4.Ox 4.0-1.0 Ctr 0.97
FOR: 1-JACK NAILS.
L MT20 3.Ox 4.0 1.0 Ctr 0.96
2-TBRACE. 3-BEARING BLOCK.
Checked for NonConcusrent 200
Lbs Moving Point Load applied
REFER TO ONLINE PLUS GENERAL
at Panel Points and Mid -panel
NOTES AND SYMBOLS SHEET FOR
on BC
ADDITIONAL SPECIFICATIONS.
Onfine Plus"' 0 Copyngnl MTek®1996-2011 Version 28.0.OW Engineering-PoNait 6=011 10.28.49 AM Page 1
Job Mark Quan Type Span Pl-Hl Left OH Right OH Engineering
2244.3-22444 FT25 1 SP 110002 10400 0 0
#22443-44 - MEL-RY - MORADI
HO 1-0-0 HO 1-4-0
TC1 4-9-15 1 6-2-3
6.6
C
2x4 3x3 3x4
'D N O E
T 3z4 3x4 3.3
H L M
&' 3
A F
1
2.4 R J G I H x4
!la „ 4x4 3x4 3x3 3.10 3.4
W:800 - W:508
R: 718 R: 692
HC - -2
ALL PLATES ARE MT2020
Scale: 0.545" = i'
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
CSI -Size- ----Lumber----
TC 0.22 2x 4 SP-#2
BC 0.66 2x 4 SP-#2
WB 0.58 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 11- 0- 2
BC Cont. 0- 0- 0 11- 0- 2
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.00 Fc=1.00 Ft--1.00
BC Fb=1.00 Fr-1.00 Ft=1.00
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 718
F 693
Jt Brg Size Required
A 8.0" 1.5".
F 5.5" 1.5"
LC# 1 Standard Loading
Der Fctrs - Lbr 1.00 Plt 1.00
plf - Dead Live* From To
TC V 20 80 0.01 11.0'
BC V 10 0 0.0' 11.01
TC V 200 0 4.8' CL-LB
Plus 1 DEC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MSTeka Online Plus-
N -O
0.13
1733 C
0.04
0.09
O -E
0.11
1066 C
0.01
0.10
--------Bottom
Chords ---------
* -K
0.18
0 T
0.00
0.18
K -07
0.45
1335 T
0.30
0.15
J -G
0.66
2233 T
0.51
0.15
G -I
0.65
2301 T
0.53
0.12
I -H
0.38
1066 T
0.16
0.22
H -F
0.22
0 T
0.00
0.22
A -B
D:13
688 C
B -K
0.58
1459 T
K -L
0.11
574 C
L -J
0.39
981 T
J -M
0.07
404 C
M -G
0.09
226 T
G -C
0.04
118 T
C -I
0.13
621 C
I -N
0.01
83 C
1 -O
0.30
754 T
H -O
0.10
555 C
e -E
0.48
1207 T
F -E
0.13
672 C
TL Defl -0.14" in J -G L/868
LL Defl -0.06" in J -G L/999
DL Defl -0.12" at G L/949
Shear // Grain in C -N 0.19
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MISS 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
B MT20 3.Ox 4.0 1.0-0.3 0.92
L MT20 3.Ox 4.0 0.5 Ctr 0.88
C mT20 6.Ox 6.0-0.5-0.6 0.76
O MT20 3.Ox 3.0-0.5 Ctr 0.86
E MT20 3.0x 4.0-0.9-0.4 0.80
K MT20 4.Ox 4.0-1.0 Ctr 0.84
J MT20 3.Ox 4.0-0.5 Ctr 0.88
H MT20 3.Ox 4.0 1.0 Ctr 0.91
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Membr CSI P Lbs
Axl-CSI-Bnd
Trusses Manufactured by:
----------Top Chords----------
East Coast Trues
B -L 0.11 1335 C
0.02 0.09
Analysis Conforms To:
L -M 0.22 2233 C
0.06 0.16
FBC2007
M -C 0.22 2317 C
0.07 0.15
TPI 2002
C -N 0.19 1737 C
0.04 0.15
Design checked for 10 psf non-
OnlinePlus'•CCopydght MHeket996-20ll
Vemlon28.0.006Engineedng-Pod
il6/2R0'Ml0.26:50AM Pagel
concurrent LL on BC.
Provide drainage to prevent
water pending.
This truss mast be installed
as shown. It cannot be
installed upside-down.
Max comp. force 2317 Lbs
Max tens, force 2301 Lbs
Connector Plate Fabrication
Tolerance - 209
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
1!!CAUTION!11 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Job Mark Quan Type Span Pl-Hl Left OH Right OH Engineering
2244a3-22444 FT26 1 SP 110300 10400 0 0
-#22443-44 - MEL-RY - MORADI-
SO 1-0-0 SO 1-4-0
TCJ 5-8-2 5-6-14
D
Sx6 2.4 3x3 3x4
3x4 3x3 3x3 C N O E
T B L M PM
1-4-0
2.4 E J G I H x4
4x4 3x3 3.3 axe 3x4
W: 800 W:800
R: 618 R: 618
SC 11-3-0
ALL PLATES ARE MT2020
Scale: 0.533" = 7'
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
CHI -Size- ----Lumber----
TC 0.18 2x 4 SP-#2
BC 0.53 2x 4 SP-#2
WB 0.54 2x 4 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 11- 3- 0
BC Cont. 0- 0- 0 11- 3- 0
pef-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1:00
TC Fb=1.15 Fc1.10 Ft=1.10
BC Ph=1.10 Fc=-1.10 Ft=1.10
Total Load Reactions (Lbsi
Jt Down Uplift Horiz-
A 619
F 619
Jt Erg Size Required
A 8.0" 1.5"
F 8.0" 1.5"
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MiTek® Online Plus-
--------
Bottom
Chords ---------
* -K
0.20
0 T
0.00
0.20
K -J
0.38
1284 T
0.26
0.12
J -G
0.53
1981 T
0.41
0.12
G -I
0.45
1845 T
0.38
0.07
I -H
0.23
849 T
0.10
0.13
H -F
0.17
0 T
0.00
0.17
A -B
0.11
590 C
B -K
0.54
1371 T
K -L
0.09
467 C
L -J
0.29
744 T
J -M
0.05
266 C
M -G
0.05
283 C
G -C
0.07
188 T
C -I
0.10
516 C
I -N
0.01
70 C
I -O
0.24
612 T
H -O
0.09
493 C
H -E
0.39
986 T
F -E
0.11
599 C
TL Defl -0.12" in J -G L/998
LL Defl -0.08" in J -G L/999
DL Defl -0.12" at G L/952
Shear // Grain in J -G 0.19
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TSH 18 Ga, Gross Area
Jt Type Plt Size R Y JSI
B MT20 3.Ox 4.0 1.0-0.3 0.88
L MT20 3.Ox 3.0 0.5 Ctr 0.82
C MT20 5.0x 6.0-0.5-0.6 0.82
E MT20 3.Ox 4.0-0.4-0.2 0.80
K MT20 4.Ox 4.0-0.5 Ctr 0.92
J MT20 3.Ox 3.0-0.5 Ctr 0.82
H MT20 3.Ox 4.0 0.5 Ctr 0.90
REFER TO ONLINE PLUS GENERAL
Membr
CSI
P Lbs
Axl-CSI-Bnd
NOTES AND SYMBOLS SHEET FOR
----------Top Chords----------
ADDITIONAL SPECIFICATIONS.
B -L
0.11
1284 C
0.01 0.10
L -M
0.18
1981 C
0.04 0.14
NOTES:
M -C
0.16
1839 C
0.03 0.13
Trusses Manufactured by:
C -N
0.10
1380 C
0.01 0.09
East Coast Truss
N -0
0.07
1376 C
0.01 0.06
Analysis Conforms To:
O -E
0.07
849 C
0.00 0.07
FBC2007
Online Plus^'®Copyright MRekQl8
2011 Version 28.0.006 Engineering-
Pomait 6=0111028:50AM Pagel
TPI 2002
Design checked for 10 ps£ non -
concurrent LL on BC.
Provide drainage to prevent
water ponding.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force - 1981 Lbs
Max tens. force 1981 Lbs
Connector Plate Fabrication
Tolerance = 20%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ 11BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Job I
Mark
Quan Type Span
P1-H1
Left OH
Right
OH
Engineering
22443-22444
FT27GE
1 Sp 110300
10400
0
0
#22443-44 - 14EL-RY
- MORADI
SO 1-0-0
SO 1-4-0
TCj
6-6-4
1
4-B-12
3.6
C
2x4
2x T 4
•2x4
H
J L
D
N
P
E
MeB
1-4-0
A
F
2x4
I
R M
G
O
Q
02.4
2x4
g
Be
- -
8
ALL PLATES ARE
MT2020
See Joint H For Typical Gable Plate Size
and Placement
Scale: 0.533" =1'
Online Plus -- Version 28.0.006
RUN DATE: 31-MAY-11
CSI -Size- ----Lumber----
TC 0.09 2x 4 SP-N2
BC 0.13 2x 4 SP-62
WB 0.06 2x 4 SP-#3
GW 0.09 2x•4 SP-#3
Brace trues as follows:
O.C. From To
TC Cont. 0- 0- 0 11- 3- 0
BC Cont. 0- 0- 0 il- 3- 0
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.00 Fc=1.00 Ftzl.00
BC Fb=1.00 Fc=1.00 Ft=1.00
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
A 1438 790 U 94 R
Jt Brg Size Required
A 135.0" 0"-to- 1351'
LCN 1 Standard Loading
Dur Fetrs - Lbr 1.00 Plt 1.00
plf - Dead Live* From To
TC V 20 80 0.0' 11.2'
EC V 10 0 0.0' 11.2'
TO V 200 0 6.5' CL-LB
Plus 6 Wind Load Case(s)
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr
CSI
P Lbs
Axl-CSI-Bnd
----------Top Chords ----------
* -H
0.06
15 T
0.00 0.06
H -J
0.08
26 C
0.00 0.08
J -L
0.09
33 C
0.00 0.09
MiTek® Online Plus-
L -C
0.05
33 C
0.00
0.05
C -N
0.05
21 T
0.00
0.05
N -P
0.07
34 T
0.00
0.07
P -E
0.06
28 T
0.00
0.06
--------Bottom
Chords ---------
A -I
0.04
0 T
0.00
0.04
I -K
0.08
0 T
0.00
0.08
K -M
0.04
0 T
0.00
0.04
M -G
0.01
0 T
0.00
0.01
G -O
0.03
0 T
0.00
0.03
O -Q
0.13
0 T
0.00
0.13
Q -F
0.06
0 T
0.00
0.06
A -B
0.05
80 C
0.00
0.05
G -C
0.01
266 C
0.00
0.01
F -E
0.06
76 C
0.00
0.06
----------Gable
Webs----------
I-H
0.04
180 C
0.03
0.01
K -J
0.06
207 C
0.00
0.06
M -L
0.05
164 C
0.03
0.02
O -N
0.06
166 C
0.00
0.06
Q -P
0.09
186 C
0.00
0.09
TL Defl 0.00" in Q -F L/999
LL Defl 0.00" in Q -F L/999
DL Defl 0.00" at L/999
Shear // Grain in I -K 0.31
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 1B Ga, Gross Area
Jt Type Plt Size X Y JSI
C MT20 3.Ox 6.0-0.5-0.6 0.69
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Provide drainage to prevent
water pending.
Refer to Gen Det 3 series for
web bracing and plating.
This truss must be installed
as shown. It cannot be
installed upside-down.
Wind Loads - ANSI / ASCE 7-05
Truss is designed as a Main
Wind -Force Resistance System.
Wind Speed: 140'mph
Mean Roof Haight: 20-0
Exposure Category: C
Occupancy Factor : 1.00
Building Type: Enclosed
Zone location: Exterior
TO Dead Load 6.0 psf
BC Dead Load 3.0 psf
Max comp. force 266 Lbe
Max tens. force 180 Lbs
Connector Plate Fabrication
Tolerance = 20%
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cared, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.EAEB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
!!!CAUTION!!! READ "BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
Online Plus"' O Capydgnt MTek®19962011 Version 28.0.008 EngineeMg -Portrait 6=0111028:51 AM Pagel
Jon
Mark
Quan
Type Span
Pl-Hl Left OH
Right OH
Engineering
22443-22444
FL3
2
M100 111108
10400 0
0
1#22443-44 - MEL-RY - MORADI
SO1-4-0
Ho 1-4-0
TCJ
1 1-2-8 II 2-0-0
II 9-8 1 9-8 1
5x5
C 3x3 3.3
3.3
3x3 3x3
3.6
A B E R
J
L S
BF
T
Pro
1-4-0
G
Q
P K
M O
N I .3
W:308 3x4
3x3 1x4
lx4 3.3
4x4
R: 667
Common Diagonal: 1-3-0
D
lx4
W:508
R: 644
SC m
6-2-8
m
6
11-11-8
Ea
ALL PLATES ABE MT2020
Scale: 0.522' = V
MiTek® Online Plus -
Online Plus -- Version 28.0.006
P -K 0.63 1464 T 0.23 0.40
strongbacks (on edge) every
RUN DATE: 26-MAY-11
K -M 0.66 1464 T 0.23 0.43
10.0 Ft. Fasten to each
M -O 0.66 1464 T 0.23 0.43
truss w/ 3-10d(0.131"x3")
CSI -Size- ----Lumber----
O -N 0.48 1098 T 0.11 0.37
nails at truss member (a).
TC 0.41 4x 2 SP-#2
N -G 0.26 0 T 0.00 0.26
This truss must be installed
BC 0.66 .4x 2 SP-#2
-------------Webs-------------
as shown. It cannot be
WB 0.31 4x 2 SP-#3
D -C 0.08 215 T
installed upside-down.
C -Q 0.30 770 T
Max comp. force 1464 Lbs
_
Brace truss as follows:
Q -R 0.15 722 C
Max tens. force 1464 Lbs
O.C. From To
R -P 0.12 321 T
Connector Plate Fabrication
TO Cont. 0- 0- 0 11-11- B
P -J 0.06 335 C
Tolerance = 10%
SC Cont. 0- 0- 0 11-11- 8
K -J 0.05 125 T
This truss is designed for a
M -L 0.07 198 T
creep factor of 1.5 which
psf-Ld Dead Live
L -O 0.09 477 C
is used to calculate total
TC 10.0 40.0
0 -S 0.14 354 T
load deflection.
BC 5.0 0.0
S -N 0.14 710 C
FABRICATOR NOTES:
TC+BC 15.0 40.0
N -F 0.31 778 T
1. EAST COAST TRUSS
Total 55.0 Spacing 24.0"
G -F 0.06 350 C
5285 ST.LUCIE BLVD.
Lumber Duration Factor 1.00
G -F 0.06 350 C
FORT PIERCE,FL 34946
Plate Duration Factor 1.00
TO Fb=1.15 Fc=1.10 Ft=1.10
TL Defl -0.11" in P -K L/999
S. Salim Cerci, P.E.
BC Fb=1.10 Fc=1.10 Ft=1.10
LL Defl -0.08" in P -K L/999
5407 Wellcraft Dr.
DL Defl -0.12" at K L/999
Greenacres, FL.33463
Total Load Reactions (Lbs)
Shear // Grain in G -G 0.32
Jt Down Uplift Horiz-
MAURICE A. SHASHOUA,
C 668
Plates for each ply each face.
P.E.#EB5251 6 19554
G 645
Plate - MT20 20 Ga, Gross Area
1908 NW 112 AVE.
Plate - MTBH 18 Ga, Gross Area
CORAL SPRINGS, FL 33071
Jt Erg Size Required
Jt Type Plt Size X • Y JSI
2. !!!CAUTION!!! READ "SCSI-B1
C 3.0" 1.5"
C MT20 5.Ox 5.0 1.0 0.5 0.66
SUMMARY SHEET" BEFORE
G 5.5" 1.5"
E MT20 3.Ox 3.0-0.9 Ctr 0.33
HANDLING , INSTALLING 6
F MT20 3.Ox 6.0 Ctr-0.2 0.84
BRACING TRUSSES.
Plus 2 Unbalanced Load Cases
D MT20 1.Ox 4.0 Ctr 0.5 0.69
3. SEE ATTACHED DETAIL SHEET
Plus 1 UBC LL Load Case(s)
Q MT20 3.Ox 4.0-0.5 Ctr 0.97
FOR: 1-JACK NAILS.
Plus 1 DL Load Cass(s)
K MT20 1.0x 4.0 Ctr 0.5 0.40
2-TBRACE. 3-BEARING BLOCK.
M MT20 1.Ox 4.0 Ctr 0.5 0.63
Checked for NonConcurrent 200
N MT20 4.Ox 4.0 Ctr 0.5 0.86
Lbs Moving Point Load applied
at Panel Points and Mid -panel
REFER TO ONLINE PLUS GENERAL
on BC
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
Membr
CSI
P Lbs
Axl-CSI-End
---------- Top Chords----------
NOTES:
A
-C
0.03
0 T
0.00
0.03
Trusses Manufactured by:
C
-E
0.05
312 C
0.00
0.05
East Coast Truss
C
-E
0.06
312 C
0.00
0.06
Analysis Conforms To:
E
-R
0.38
567 C
0.00
0.38
FBC2007
R
-J
0.39
1301 C
0.01
0.3B
TPI 2002
J
-L
0.41
1464 C
0.01
0.40
Design checked for 10 psf non-
*
-S
0.40
1260 C
0.00
0.40
concurrent LL on BC.
S
-F
0.32
584 C
0.00
0.32
Max gap between edge of brg
--------Bottom
Chords---------
and end vertical or
D
-Q
0.30
0 T
0.00
O:30
diagonal web is 1/2".
Q
-P
0.46
1086 T
0.11
0.35
Provide 2X6 continuous
Online PNs" 0 Cepydght MJekO 1998-2011
Version 28.0.006 Engineering -Portrait 11W011 10:28:52 AM Pagel
Joe
Mark
Quan Type Span P1-H1
Left OH Right OH
Engineering
22443-22444
FL4
7 Mloo 130000 10400
0 0
I
#22443-44 - MEL-RY - MORADI
HO 1-4-0
HO 1-4-0
Tel
1 1-2-8 II 2-0-0 II
1-4-8
1
5.5
C 3x3 3.3
3.3 3.3
3x3 3x6
A B E R
J L
S H F
T
1-4-0
G
Q
P x M
O N1 2.3
W:308 4x4
3.3 lx4 1.4
3x3 4x4 n
R: 725
Common Diagonal: 1-3-0
D
/IIJI
lx4
HGR
R: 701
ALL PLATES ARE MT2020
Scale: 0.484" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size-
TC 0.45 4x 2 SP-42
BC 0.65 4x 2 SP-#2
WB 0.35 4x 2 SP-43
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 0- 0
BC Cont. 0- 0- 0 13- 0- 0
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Eb=1.15 Fc=1.10 Ft-1.10
BC Fb=1.10 Fc=1.10 Ftl.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 725
G 702
Jt Brg Size Required
C 3.01' 1.5"
G 3.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
* -C 0.03 0 T 0.00 0.03
C -E 0.06 346 C 0.00 0.06
C -E 0.06 346 C 0.00 0.06
E -R 0.36 629 C 0.00 0.36
R -J 0.37 1483 C 0.01 0.36
MSTekO Online Plus-
* -L
0.36
1759 C
0.01 0.35
L -S
0.45
1495 C
0.01 0.44
S -F
0.44
658 C
0.00 0.44
--------Bottom
Chords ---------
D -Q
0.29
0 T
0.00 0.29
Q -P
0.4B
1200 T
0.12 0.36
P -K
0.65
1759 T
0.27 0.38
K -M
0.65
1759 T
0.27 0.38
M -0
0.64
1759 T
0.27 0.37
O -N
0.48
1237 T
0.12 0.36
N -G
0.27
0 T
0.00 0.27
-------------
Webs -------------
D -C
0.08
214 T
C -Q
0.34
854 T
Q -R
0.16
795 C
R -P
0.16
404 T
P -J
0.09
479 C
K -J
0.06
156 T
M -L
0.05
139 T
L -0
0.09
451 C
O -S
0.14
374 T
S -N
0.16
804 C
N -F
0.35
B77 T
G -F
0.07
382 C
G -F
0.07
382 C
TL Defl -0.13" in M -O L/999
LL Defl -0.09" in M -O L/999
DL Defl -0.12" at M L/999
Shear // Grain in G -G 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 18 Ga. Gross Area
Jt Type Plt Size X Y JSI
C MT20 S.Ox 5.0 1.0 0.5 0.73
E MT20 3.Ox 3.0-0.9 Ctr 0.33
F MT20 3.Ox 6.0 Ctr-0.2 0.95
D MT20 1.10x 4.0 Ctr 0.5 0.68
Q MT20 4.Ox 4.0 Ctr 0.5 0.99
K M720 l.Ox 4.0 Ctr 0.5 0.50
M M720 l.Ox 4.0 Ctr 0.5 0.45
N MT20 4.Ox 4.0 Ctr 0.5 0.97
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/211.
Provide 2X6 continuous
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-10d(0.131"x39
nails at truss -
ember(s)-This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1759 the
Max tone. force 1759 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.EAEB5251 S 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
!!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-REARING BLOCK.
Online Plus" GCopyegm MRek0t096-2011 Verson 28.0.006 EngineeMg-Pmtratt 52201110:28:53AM Pagel
Jmb
Mark
Quan Type Span Pl-Hl Left OH
Right OH
Engineering
22443-22444
FLS
1 3 M100 130308 10400 0
0
'#22443-44 - MEL-RY - MORADI
RO 1-4-0
HO 1-4-0
TCj
11-2-8 II 2-0-0 II 9-4 1 9-4 I
m
0
Sx5
1.3
C 3x3 3.3
3x3 lx4 3x3 3.3
3x6
A R D Q
_ E F R S
G
T
1-4-0
H
W:308 P
R: 734 4.4
O J I N
3.3 1.4 3x3 3.3
M 4.4
4.4
K
Common Diagonal: 1-3-0
M
1x4
W:308
R: 711
BC m 6-2-0
6-9-3
13
ALL PLATES ARE MT2020
Scale: 0.468" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.38 4x 2 SP-#2
BC 0.61 4x 2 SP-#2
WB 0.35 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 3-
BC Cont. 0- 0- 0 13- 3-
psf-Ld Dead Live
TO 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration. Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fr-1.10 Fta1.10
BC Eb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 734
H 712
Jt Erg Size Required
C 3.011 1.51T
H 3.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MOMbr CSI P Lbs Axl-CSI-End
---------- Top Chords __-_-_____
A -C 0.03 0 T 0.00 0.03
C -D 0.06 351 C 0.00 0.06
C -D 0.06 351 C 0.00 0.06
D -Q 0.36 638 C 0.00 0.36
Q -E 0.38 1513 C 0.01 0.37
E -F 0.38 1799 C 0.01 0.37
8 -R 0.38 1799 C 0.01 0.37
R -S 0.35 IB41 C 0.02 0.33
S -G 0.33 664 C 0.00 0.33
--------Bottom Chords ---------
X -P 0.29 0 T 0.00 0.29
MiTek® Online Plus-
* -0
0.48
1218 T
0.12 0.36
O -J
0.61
1799 T
0.28 0.33
J -1
0.61
1799 T
0.28 0.33
I -N
0.59
1701 T
0.28 0.31
N -M
0.58
1247 T
0.12 0.46
M -H
0.26
0 T
0.00 0.26
-------------
Webs --__-________
K -C
0.08
214 T
C -P
0.34
866 T
P -Q
0.16
808 C
Q -O
0.16
419 T
O -E
0.09
480 C
J -E
0.06
157 T
I -F
0.04
232 C
I -R
0.15
398 T
R -N
0.06
300 C
N -S
0.16
406 T
S -M
0.16
810 C
M -G
0.35
884 T
H -G
0.07
387 C
H -G
0.07
387 C
TL Defl-0.131' in I -N L/999
LL Defl -0.09" in I -N L/999
DL Defl-0.1211 at I L/999
Shear // Grain in H -H 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MTSH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
C MT20 5.Ox 5.0 1.0 0.5 0.74
D MT20 3.Ox 3.0-0.9 Ctr 0.33
F MT20 1.OX 4.0 Ctr-0.5 0.33
G MT20 3.Ox 6.0 Ctr-0.2 0.96
K MT20 l.Ox 4.0 Ctr 0.5 0.68
P MT20 4.Ox 4.0 Ctr 0.5 1.00
J MT20 1.0x 4.0 Ctr 0.5 0.50
M MT20 4.Ox 4.0 Ctr 0.5 0.98
H MT20 4.Ox 4.0 1.2 0.5 0.17
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FEC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/211.
Provide 2X6 continuous
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-10d(0.131"x3")
nails at truss member(s).
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp, force 1799 Lbs
Max tens. force 1799 Iles
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SRASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Onl'me Plus"'OCopyright M7ekOr1Sg&2011Vesian28.O.Ws Engineemg-Pa H 6=01110:28:UAM Pagel
Job
Mark
Quan
Type
Span
Pl-Hl Left OH
Right OH
Engineering
2244177-22444
FL 1
3
M100
71008
10400 0
0
I
422443-44 - MEL-RY
- MORADI
HO 1-4-0
NO 1-4-0
m
0
TC1
I 1-1-12
I I
2-0-0
I I 1-2-4 1
3x6
1.3
C
3.3
3.3
3.3
3.4
D
E
F
1-4-0 s!4.
1
s
W :308
N
J
I M
4.4
R: 436
3.3
1x4
1x4 3.3
Common Diagonal: 1-3-0
.z.
x
1.4
w:508
R: 414
BC -8
3-7-
3-11-4
A
'
ALL PLATES ARE MT2020
Scale: 0.732" = V
r,
a
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.32 4x 2 SP-N2
BC 0.47 4x 2 SP-N2
WE 0.17 4x 2 SP-k3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 7-10- 8
BC Cont. 0- 0- 0 7-10- 8
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 F�1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 437
H 414
Jt erg Size Required
C 3.0" 1.5"
H 5.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Casa(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MSTek® Online Plus-
* -D
0.07
171 C
0.00
0.07
D -8
0.29
311 C
0.00
0.29
E -F
0.28
591 C
0.00
0.28
F -G
0.32
322 C
0.00
0.32
--------Bottom Chords ---------
* -N
0.28
0 T
0.00
0.28
N -J
0.37
591 T
0.06
0.31
J -I
0.47
591 T
0.08
0.39
I -M
0.39
591 T
0.06
0.33
M -H
0.27
0 T
0.00
0.27
-------------
Webs _____-______-
K -C
0.08
218 T
C -N
0.16
422 T
N -E
0.08
396 C
J -E
0.06
161 T
I -F
0.05
148 T
F -M
0.07
374 C
M -G
0.17
428 T
H -G
0.04
223 C
H -G
0.04
223 C
TL Defl -0.04" in J -I L/999
LL Defl -0.03^ in J -I L/999
DL Defl 0.00" at L/999
Shear // Grain in H -H 0.33
Plates for each ply each face.
Plate - MT20 20 Ga, Grose Area
Plate - MTBH 18 Ga, Grose Area
Jt Type Plt Size X Y JSI
D MT20 3.Ox 3.0-0.9 Ctr 0.33
G MT20 3.Ox 4.0 0.5 Ctr 0.78
K MT20 1.Ox 4.0 Ctr 0.5 0.69
J MT20 1.Ox 4.0 Ctr 0.5 0.51
I MT20 S.Ox 4.0 Ctr 0.5 0.47
H M720 4.Ox 4.0 1.2 0.5 0.13
REFER TO ONLINE PLUS Gw74F.Rar.
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
Mamba CSI P Lbs Axl-CSI-Hnd NOTES:
----------Top Chords---------- Trusses Manufactured by:
A -C 0.03 0 T 0.00 0.03 East Coast Trues
C -D 0.06 171 C 0.00 0.06 Analysis Conforms To:
Online Plus^'OCop!rtiBM MJek07996-2017 Version 29.0.098 Fs91naeflng-Pomalt 6/1(2071702a:54 AM Pagel
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and sad vertical or
diagonal web is 1/211.
This truss moat be installed
as shown. It cannot be
installed upside-down.
Max comp. Force 591 Lbs
Max teas. force 591 I.ba
Connector Plate Fabrication
Tolerance = 10$
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIEACE,FL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAVRICE A. SHASHOUA,
P.E.NEH5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!lCAUTIONII! READ "BC32-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TelU10E. 3-RcnRrNG BLOCK.
Job Mark Quan Type Span P1-H1 Left OH Right OH Engineering
22443-22444 FL 1 M100 40409 10400 0 0
#22443-44 - MEL-RY - MORADI
NO 1-4-0 NO 1-4-0
m
0
TC 1 I 9-1 I � 1
4x4 lx3
C 1x4 3.3 2.3
_ D R
T
1-4-0
1 ty " F
G J I
W:308 1x4 3x3 3.6
R: 267 Common Diagonal: 1-3-0
W:508
R: 270
HC -
5
ALL PLATEN ARE MT2020
Scale: 0.760" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size- ----Lumber----
TC 0.29 4x 2 SP-#2
BC 0.44 4x 2 SP-#2
WB 0.08 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 4- 4- 9
BC Cont. 0- 0- 0 4- 4- 9
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 -40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fr-1.10 Ft=1.10
BC Fb=1.10 Fr-1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 268
I 270
Jt Erg Size Required
C 3.5" 1.5"
I 5.5" 1.5"
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
* -C 0.08 0 T 0.00 0.08
C -K 0.29 161 C 0.00 0.29
MiTek® Online Plus"
K -E
0.29 0 T 0.00
0.29
--------Bottom
Chords ---------
* -J
0.29 0 T 0.00
0.29
J -I
0.44 140 T 0.01
0.43
I -F
0.27 0 T 0.00
0.27
G -C
0.08
215 T
C -J
0.08
219 T
J.-K
0.04
104 T
K -I
0.04
240 C
I -E
0.00
4 T
I -E
0.00
4 T
TL Defl 0.01" in J -I L/999
LL Defl 0.01" in J -I L/999
DL Defl 0.00" at L/999
Shear // Grain in I -F 0.33
Plates for each ply each face.
Plate - MT20 20 Ga. Gross Area
Plate - MTOR 18 Ga, Gross Area
Jt Type Plt Size R Y JSI
C MT20 4.Ox 4.0 0.5 1.0 0.62
G MT20 S.Ox 4.0 Ctr 0.5 0.69
1 MT20 3.Ox 6.0 1.0 Ctr 0.23
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FEC2007
TPI 2002
Design checked for SO psf non -
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/219.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 240 Lbs
Max tens. force 219 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5205 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres. FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
Ongne Pioa"' 0 Copyright MJek01996-2011 Version 28.0.006 Engneenng -portrait 6=01110:28:55AM Pagel
Job Mark Quan Type Span P1-H3 Left OH Right OH Engineering
22443-22444 FLS 1 1 M100 90914 10400 0 0
#22443-44 - MEL-RY - MORADI
SO 1-4-0 HO 1-4-0
TC 1 1 9-12 1 9-12 1 1 10-11 1 _
3x4 3x3 3x3 1x4 3.3 1x4 4.4
AJ 0 P H Q C DE F
T
1-4-0
I
2x3 K N M H,i L G
3.3 3x3 3x6 3.3 1x4
Common Diagonal: 1-3-0 W:308
R: 244
7 M
Cant:3-10-14
W:508 W:508
R: 281 R: fill
e_ _ _ _lb-11
69-9-24
ALL PLATES ARE MT2020
Scale: 0.580" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size- ----Lumber----
TC 0.34 4x 2 SP-#2
BC 0.50 4x 2 SP-#2
WB 0.11 4x 2 SP-#3
Brace truss as follows:
0. C. From To
TC Cont. 0- 0- 0 9- 9-14
BC Cont. 0- 0- 0 9- 9-14
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fr-1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ftn1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
I 281
H 612
D 244
Jt Erg Size Required
I 5.5" 1.5"
H 5.5" 1.5"
D 3.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case (a)
Plus 1 DL Load Cases)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MSTek® Online Plus-
P -B
0.12
203 T
0.04 0.08
B -g
0.33
203 T
0.04 0.29
Q -D
0.31
132 C
0.00 0.31
D -F
0.07
0 T
0.00 0.07
--------Bottom
Chords ---------
I -H
0.29
0 T
0.00 0.29
N -M
0.50
317 T
0.04 0.46
M -H
0.26
51 T
0.00 0.26
H -L
0.32
97 C
0.00 0.32
L -G
0.27
0 T
0.00 0.27
-------------
Webs -------------
I -A
0.02
151 C
I -A
0.02
151 C
A -N
0.11
278 T
N -0
0.04
193 C
O -M
0.04
223 C
M -P
0.10
251 T
P -H
0.07
391 C
H -B
0.00
34 C
H -Q
0.06
331 C
Q -L
0.05
139 T
L -D
0.07
179 T
G -D
0.08
203 T
TL Defl 0.02" in N -M L/999
LL Defl 0.02" in N -M L/999
DL Defl 0.00" at L/999
Shear // Grain in I -I 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 0.51
B MT20 1.Ox 4.0 Ctr-0.5 0.33
D MT20 4.Ox 4.0-0.5 1.0 0.58
G MT20 1.Ox 4.0 Ctr 0.5 0.65
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Membr CSI P Lbs Axl-CSI-Bnd Trusses Manufactured by:
----------Top Chords---------- East Coast Truss
A -0 0.34 209 C 0.00 0.34 Analysis Conforms To:
O -P 0.34 180 C 0.00 0.34 FEC2007
Odin Plus- m Copoghl MRekV 1996.2011 Vamicn 2&0.006 Engineenng-POmall aW011 1 :28:55 AM Pagel
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/211.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 391 Lbs
Max tens. force 317 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SRASHOUA,
P.E.#EB5251 S L9554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !11CAUTION!11 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING S
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEhRTNG BLOCK.
Job
Nark
Quan
Type
Span
Pl-Hl
Left OH Right OH
Engineering
22443-22444
FL9
1
M100
130506
10400
0 0
#22443-44 - MEL-RY - MORADI
SO 1-4-0
BO 1-4-0
TC 1
1 9-12 1 9-12 1
1 1-1-6 11 9-5 1
3x4 3x3
3x3 3.3
3x3
3.3 2x3 4x4
e
A L Y
Z B
AA
88 CD F G
�-
T
'1W
1-4-0
M&NOW,
x
2x3
W:308
A: 258
Cant:l- 3- 8
W:508
W:508
W:508 '
R: 266 Common Diagonal: 1A2-954
R: 269
BC 5-8-4
1
S-8-7
-7 1-
13-5-6
ALL PLATES AVE 1472020
Scale: 0.421" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.35 4x 2 SP-#2
BC 0.51 4x 2 SP-#2
WB 0.19 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 1-14
BC Cont. 0- 0- 0 13- 1-14
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt
Down Uplift Horiz-
K
267
J
854
T
269
F
258
Jt
Erg Size
Required
K
5.5"
1.5"
J
5.5"
1.5"
T
5.5"
1.5"
F
3.5"
1.5"
Plus 2 Unbalanced Load Cases
Plus 1 DEC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lba Axl-CSI-Had
----------Top Chords ----------
A -Y 0.35 196 C 0.00 0.35
Mi1'elc® Online Plus-
* -Z
0.35
146 C
0.00
0.35
Z -e
0.30
412 T
0.08
0.22
e -AA
0.32
109 T
0.01
0.31
AA -BB
0.31
311 C
0.00
0.31
BB-C
0.19
139 C
0.00
0.19
C -E
0.08
76 C
0.00
0.08
C -E
0.09
76 C
0.00
0.09
E -F
0.35
0 T
0.00
0.35
F -G
0.02
0 T
0.00
0.02
--------Hottam
Chords ---------
* -X
0.29
0 T
0.00
0.29
X -W
0.49
281 T
0.03
0.46
W -J
0.26
215 C
0.00
0.26
J -V
0.29
412 C
0.00
0.29
V -U
0.51
314 T
0.04
0.47
U -T
0.30
309 T
0.01
0.29
T -I
0.30
309 T
0.01
0.29
I -H
0.18
0 T
0.00
0.18
A -A
0.02
142 C
K -A
0.02
142 C
A -X
0.10
261 T
R -Y
0.03
169 C
Y -W
0.06
303 C
W -Z
0.11
275 T
Z -J
0.07
393 C
J -B
0.10
520 C
H -V
0.19
476 T
V -AA
0.08
430 C
AA-U
0.06
171 T
U -BB
0.05
128 T
BB -I
0.05
285 C
I -C
0.02
146 C
I -E
0.09
233 T
H -E
0.08
222 T
TL Defl 0.02" in X -W L/999
LL Defl 0.02" in X -W L/999
DL Defl -0.12" at U L/480
Shear // Grain in F -F 0.37
Plates for each ply each face.
Plate - MT20 20 Ga, Grose Area
Plate - MTBH 18 Ga, Grose Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 0.48
E 14T20 4.Ox 4.0-0.5 1.0 0.65
E MT20 S.Ox 9.0 Ctr 0.5 0.71
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast TivBa
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 ps£ non -
concurrent LL on BC.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 520 Lbs
Max tens. force 476 Lbs
Connector Plate Fabrication
Tolerance = 106
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S.
Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33963
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORN. SPRINGS, FL 33071
2. !!lCAUTION!11 READ "SCSI-81
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACKED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBAACE. 3-HEARING BLOCK.
Online Plus^' ® Copynght MReke t990-2011 Version 28.0.006 EnginaeM9-Patrail 6I1J2011 10:2a:56 AM Pagel
Jon
Mark
Quan
Type
Span
Pl-Hl
Left OH
Right OH
Engineering
22443-22444
FLIO
1
M100
130009
10400
0
0
#22443-44 - MEL-RY - MORADI
HO 1-4-0
NO 1-4-0
TC�
I 1-1-7 111-1-101
I
3x4
3x3
3x3
3x3
3.6
3x3 5x5
D
A J
Q
R
H
H
C E F
TManWEE
1-4-0
am
Im
_
in
- 2x3
n
lul
Covwon
Diagonal:
1-3-0
y1
Yf:�'*a'jl
W:308
R: 159
U: 243
Cant:2- 7-10
HGR
W:508
G
lx4
R: 488
R:3083
HC
- -
- -
0
m
g
13-0-9
ALL PLATES ARE W2020
Scale: 0.417" =1'
o.
ME
�,.
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size- ----Lumber----
TC 0.38 4x 2 SP-#2
BC 0.59 4x 2 SP-#2
WB 0.28 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 0- 9
EC Cont. 0- 0- 0 13- 0- 9
pef-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55,0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fr-1.10 Fta1.10
BC Pb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
I 489
H 1084
D 159 244 G
G = Gravity Uplift
Jt Erg Size Required
I 3.5" 1.5"
R 5.5" 1.5"
D 3.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 DEC LL Load Case (a)
Plus 1 DL Load Case(s)
Checked for NonConcuxrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Hnd
----------Top Chords----------
A -Q 0.35 414 C 0.00 0.35
Q -R 0.35 822 C 0.00 0.35
MiTek® Online Plus"
R -S
0.29
634 C
0.00
0.29
S -B
0.34
123 T
0.02
0.32
B -C
0.38
323 T
0.06
0.32
C -D
0.09
177 T
0.03
0.06
C -D
0.09
177 T
0.03
0.06
D -F
0.03
0 T
0.00
0.03
--------Bottom
Chords ---------
I -P
0.29
0 T
0.00
0.29
P -O
0.46
768 T
0.08
0.38
O -N
0.59
851 T
0.10
0.99
N -M
0.51
390 T
0.04
0.47
M -H
0.29
616 C
0.00
0.29
H -L
0.20
616 C
0.00
0.20
L -G
0.26
0 T
0.00
0.26
I -A
0.05
265 C
I -A
0.05
265 C
A -P
0.22
551 T
P -Q
0.10
493 C
Q -O
0.07
184 T
O -R
0.05
138 T
R -N
0.06
307 C
N -S
0.13
345 T
3 -M
0.14
714 C
M -e
0.28
704 T
H -H
0.21
1052 C
8 -L
0.16
917 T
L -D
0.09
438 C
G -D
0.08
205 T
TL Defl -0.03" in O -N L/999
LL Defl -0.02" in O -N L/999
DL Defl -0.12" at O L/927
Shear // Grain in I -I 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Grose Area
Plate - MTBH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 1.00
8 MT20 3.Ox 6.0 Ctr-0.2 0.88
C MT20 3.Ox 3.0 0.9 Ctr 0.33
D 14T20 5.Ox 5.0-1.0 0.5 0.29
M MT20 3.Ox 9.0 0.5 Ctr 0.99
8 MT20 1.Ox 4.0 Ctr 0.5 0.70
G MT20 1.Ox 4.0 Ctr 0.5 0.66
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 paf non -
concurrent LL on BC.
Max gap between edge of bxg
and end vertical or
diagonal web is 1/2".
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1052 Lbs
Max tens. force B51 Lbs
Connector Plata Fabrication
Tolerance = 10&
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 3T.LUCIE BLVD.
FORT PIERCE,FL 39946
S. Salim Cexci, P.E.
5407 Wellcraft Dr.
Greanacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EH5251 6 19554
1906 NW 112 AVE.
CORAL SPRINGS, FL 33071
2, O)CAUTIONIII READ "SCSI-Bl
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-THAACE. 3-HEARING BLOCK.
Onfina Plus"' 0 CapyagM MRek®1996-2011 Version 28.0.006 EngneeMO-PaVelt BI22011 16.2B:5] AM Pagel
Job
Mark
Quan
Type Span
Pl-Hl Left
OH Right OH
Engineering
2244.E-22444
FLll
1
M100 130308
10400 0
0
R22443-44 - MEL-RY - MORADI
SO 1-4-0
HO 1-4-0
TCI
1 1-1-7 1
1
3x4 3x3
3.3 3x3
3.6
3x3 Sx5
A J Q
R S
B
C D F
T
1-4-0
I
2x3 K P
0
N
M H
L G
3x3
3x3
3.3
3.4 1x4
3.3 1x4
Common Diagonal: 1-3-0
W:308
R: 169
U: 212 Cant:2-10- 9
HGR
W:508
R: 488
R:1071
C
_ _
e
m
13-3-8
EzI
ALL PLATES ARE MT2020
Scale: 0.409" = V
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size-
TC 0.43 4x 2 SP-#2
BC 0.59 4x 2 SP-#2
WE 0.28 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 3- 8
BC Cont. 0- 0- 0 13- 3- 8
paf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft-1.10
BC Fb=1.10 F�1.10 Ft-1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
I 489
H 1072
D 170 212 G
G = Gravity Uplift
Jt Erg Size Required
I 3.5" 1.5"
H 5.5" 1.5"
D 3.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
__________Top Chords -_-_______
A -Q 0.35 413 C 0.00 0.35
Q -R 0.35 822 C 0.00 0.35
MiTek® Online Plus-
R -S
0.28
634 C
0.00
0.28
S -B
0.39
123 T
0.02
0.37
B -C
0.43
321 T
0.09
0.37
C -D
0.10
176 T
0.03
0.07
C -D
0.11
176 T
0.03
0.08
D -F
0.03
0 T
0.00
0.03
--------Bottom
Chords ---------
I -P
0.29
0 T
0.00
0.29
P -O
0.56
768 T
0.08
0.48
O -N
0.59
850 T
0.10
0.49
N -M
0.51
390 T
0.04
0.47
M -H
0.29
616 C
0.00
0.29
H -L
0.22
616 C
0.00
0.22
L -G
0.31
0 T
0.00
0.31
I -A
0.05
265 C
I -A
0.05
265 C
A -P
0.22
551 T
P -Q
0.10
493 C
Q -O
0.07
184 T
O -R
0.05
138 T
R -N
0.06
309 C
N -S
0.13
347 T
S -M
0.14
713 C
M -B
0.28
705 T
H -B
0.20
1042 C
B -L
0.16
401 T
L -D
0.08
418 C
G -D
0.08
206 T
TL Defl -0.03" in O -N L/999
LL Defl -0.02" in O -N L/999
DL Defl -0.12" at O L/927
Shear // Grain in I -I 0.32
Plates for each ply each face.
Plate - MT20 20 Ga. Gress Area
Plate - 14TSH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 1.00
B MT20 3.Ox 6.0-0.2 Ctr 1.00
C MT20 3.Ox 3.0 0.9 Ctr 0.33
D MT20 5.Ox 5.0-1.0 0.5 0.30
M MT20 3.Ox 4.0 0.5 Ctr 0.99
H MT20 I.Ox 4.0 Ctr 0.5 0.70
G MT20 1.Ox 4.0 Ctr 0.5 0.66
REFER TO ONLINE PLUS GENERAL.
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 paf non -
concurrent LL on BC.
Max gap between edge of brg
and end Vertical or
diagonal web is 1/211.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1042 Lbs
Max tens. force 850 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellczaft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTIONI!1 READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus^ OCopydght MTak®1g96-2011Version28.0.006Englneatlng-P.M t 6=01110:28:58AM Pagel
son
Nark
Quan
Type Span PI -HI
Left OH Right
OH
Engineering
22443-22444
Fr 2
i
Mioo 130607 10400
0 0
#22443-44 - MEL-RY - MORADI
-
HO 1-4-0
HO 1-4-0
TCJ
I10-1511 2-0-0 II 11-8 1
3.8 3x3
3x3 _ 3x3
1x4 4.4
3x3 5EX50
A L R
S B
C T
D F
T
1-4-0
1 K
2.3 NQ P
O J
]:
N
4x4 3x3
3x3 lx4
4x4
4.4 W:308
n
Ij
Common Diagonal: 1-3-0
R: 753
II
B
lx4
BGR
R: 731
BC
-
- -
0
m
A
13-6-7
ALL PLATES ARE Mr202O
Scale: 0.456" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.08 4x 2 SP-#2
BC 0.94 4x 2 SP-#1
WB 0.36 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 6- 7
BC Cont. 0- 0- 0 13- 6- 7
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor. 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fr-1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
X 731
E 754
Jt Erg Size Required
K 3.5" 1.5"
E 3.0" - 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurxent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr
CSI
P Lbs
Axl-CSI-Bnd
----------Top Chords ----------
* -R
0.33
688 C
0.00
0.33
R -S
0.36
1601 C
0.02
0.34
S -B
0.51
1890 C
0.04
0.47
B -C
0.88
1744 C
0.02
0.86
C -T
0.88
1744 C
0.02
0.86
T -D
0.32
622 C
0.00
0.32
D -E
0.07
342 C
0.00
0.07
D -E
0.08
342 C
0.00
0.08
E -G
0.03
0 T
0.00
0.03
--------Bottom Chords ---------
K -Q
0.22
0 T
0.00
0.22
MiTekO Online Plus-
Q -P
0.41
1289 T
0.10
0.31
P -0
0.51
1896 T
0.15
0.36
O -J
0.94
1744 T
0.24
0.70
J -I
0.94
1744 T
0.24
0.70
I -N
0.72
1282 T
0.15
0.57
N -H
0.25
OT
0.00
0.25
K -A
0.07
398 C
K -A
0.07
398 C
A -Q
0.36
916 T
Q -R
0.17
836 C
R -P
0.17
433 T
P -S
0.08
409 C
S -O
0.06
168 T
O -B
0.13
339 T
J -B
0.05
299 C
I -C
0.07
397 C
I -T
0.32
815 T
T -N
0.19
916 C
N -E
0.33
844 T
H -E
0.08
210 T
TL De£1 -0.26" in O -J L/602
LL Defl -0.17" in O -J L/908
DL Defl -0.12" at J L/999
Shear // Grain in B -C 0.35
Plates for each ply each face.
Plate - MT20 20 Ga, Gress Area
Plate - 14TSH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 8.0 1.4-0.3 0.94
C MT20 1.Ox 4.0 Ctr-0.5 0.33
T MT20 4.Ox 4.0 Ctr-0.5 0.86
D MT20 3.Ox 3.0 0.9 Ctr 0.33
E MT20 S.Ox 5.0-1.0 0.5 0.72
Q MT20 4.Ox 4.0-0.2 0.5 0.90
J MT20 S.Ox 4.0 Ctr 0.5 0.33
I MT20 4.Ox 4.0 0.5 0.5 0.75
N MT20 4.Ox 4.0 Ctr 0.5 0.97
H MT20 1.Ox 4.0 Ctr 0.5 0.67
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and end Vertical or
diagonal web is 1/211.
Provide 2X6 continuous
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-10d(0.131"x3")
nails at truss member(s).
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1890 Lbs
Max tens. force 1896 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcra£t Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 S 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !11CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
Onfne Plus"' OCopydght MTekO 1995-2011 Vemlon 28.0.006 Engineenng - PoRreO 60=1 102B:59 AM Page l
Job
Mark
Quan Type
Span
Pl-Hl Left OH
Right
OH
Engineering
2244,3-22444
FL13
I 1 M100
100514
10400. 0
0
I
#22443-44 - MEL-RY - MORADI
SO 1-4-0
HO 1-4-0
m
0
TC'rl
I 1-2-15
II 2-0-0
II 1-2-7 I
1
Sx5
1.3
P
4.4
3x3
2x4
1x4 3x3
3.3
A
O
I
K P
H
E D
T B
1-4-0
-
C
:;.a
axe
N
i.-:
W:308
3.3
3x3
3.3
3x3
R: 579
Common
Diagonal: 1-3-0
O
lx4
W:308
R: 557
g
_
_ _
m
0
m
5
ALL PLATES ARE
MT2020
Scale: 0.571^ = 1'
MiTek® Online Plus -
Online Plus -- Version 28.0.006
K -P 0.34 1077 C 0.00 0.34
RUN DATE: 26-MAY-11
P -H 0.28 464 C D.00 0.28
NOTES:
H -F 0.06 255 C D.00 0.06
Trusses Manufactured by:
CSI -Size- ----Lumber----
H -F 0.07 255 C 0.00 0.07
East Coast Truss
TC 0.34 4x 2 SP-#2
F -D 0.03 0 T 0.00 0.03
Analysis Conforms To:
BC 0.63 4x 2 SP-#2
--------Bottom Chords---------
FBC2007
WB 0.26 4x 2 SP-#3
C -N 0.33 0 T D-.00 0.33
TPI 2002
N -J 0.63 907 T 0.10 0.53
Design checked for 10 paf non -
Brace truss as follows:
J -L 0.55 1077 T 0.13 0.42
concurrent LL on BC.
O.C. From To
L -M 0.62 883 T 0.10 0.52
Max gap between edge of brg
TC Cont. 0- 0- 0 10- 5-14
M -G 0.33 0 T 0.00 0.33
and end vertical or
BC Cont. 0- 0- 0 10- 5-14
-------------Webs-------------
diagonal web is 1/211.
C -A 0.05 303 C
This truss must be installed
pe£-Ld Dead Live
C -A 0.05 303 C
as shown. It cannot be
TC 10.0 40.0
A -N 0.26 649 T
installed upside -down -
BC 5.0 0.0
N -O 0.12 583 C
Max comp. force 1077 Lbs
TC+BC 15.0 40.0
O -J 0.14 371 T
Max tens. force 1077 Lbs
Total 55.0 Spacing 24.0"
J -I 0.03 191 C
Connector Plate Fabrication
Lumber Duration Factor 1.00
L -K 0.04 205 C
Tolerance = 10%
Plate Duration Factor 1.00
L -P 0.15 392 T
This truss is designed for a
TC Fb=1.15 Fc=1.10 Ft=1.10
P -M 0.12 583 C
creep factor of 1.5 which
BC Fb=1.10 rc=1.10 Ft=1.10
M -F 0.25 630 T
is used to calculate total
G -F 0.08 203 T
load deflection.
Total Load Reactions (Lbs)
FABRICATOR NOTES:
Jt Down Uplift Horiz-
TL Defl -0.06" in N -J L/999
1. EAST COAST TRUSS
C 558
LL Defl -0.05" in N -J L/999
5285 ST.LUCIE BLVD.
F 580
DL Defl -0.12" at J L/955
FORT PIERCE,FL 34946
Shear // Grain in C -C 0.32
it Brg Size Required
S. Salim Cerci, P.E.
C 3.5'. 1.51,
Plates for each ply each face.
5407 Wellcraft Dr.
F 3.0" 1.51,
Plate - MT20 20 Ga. Gross Area
Greenacres, FL.33463
Plate - MT8H 18 Ga, Gross Area
' Plus 2 Unbalanced Load Cases
Jt Type Plt Size X Y JSI
MAURICE A. SHASHOUA,
Plus 1 UBC LL Load Case(s)
A MT20 4.Ox 4.0-0.5-0.5 1.00
P.E.#EB5251 6 19554
Plus 1 DL Load Case(s)
I MT20 1.Ox 4.0 Ctr-0.5 0.33
1908 NW 112 AVE.
K MT20 I.OX 4.0 Ctr-0.5 0.33
CORAL SPRINGS, FL 33071
Checked for Nonconcurrent 200
H MT203.Ox 3.0 0.9 Ctr 0.33
2. !!!CAUTION!!! READ "SCSI-B1
Lbe Moving Point Load applied
F MT20 5.Ox 5.0-1.0 0.5 0.54
SUMMARY SHEET" BEFORE
at Panel Points and Mid -panel
C MT20 4.Ox 4.0 Ctr 0.5 0.16
HANDLING , INSTALLING S
on BC
N MT20 3.Ox 3.0-0.5 Ctr 0.95
BRACING TRUSSES.
M MT20 3.Ox 3.0 0.2 Ctr 1.00
3. SEE ATTACHED DETAIL SHEET
Membr CSI P Lbs Axl-CSI-Bnd
G MT20 1.0x 4.0 Ctr 0.5 0.65
FOR: 1-JACK NAILS.
---------- Top Chords ----------
2-TBRACE. 3-HEARING BLOCK.
A -O 0.33 487 C 0.00 0.33
REFER TO ONLINE PLUS GENERAL
O -I 0.33 1077 C O.Ol7 0.33
NOTES AND SYMBOLS SHEET FOR
I -K 0.34 1077 C 0.00 0.34
ADDITIONAL SPECIFICATIONS.
Online Plus'a 0 Copyright MirekO 199 2011 Version 28.0.OW Engineering - PONaae 01110:29:00 AM Pagel
Job Mark Quan Type Span Pl-HI Left OH Right OH Engineering
22443-22444 FL14 I 1 M100 100812 10400 0 0
1#22443-44 - MEL-RY - MORADI
NO 1-4-0 SO 1-4-0
m
0
mcPi i 1-2-15 11 z-o-o l i e-10 i e-u I I
1x3 5x5
F
3.6 3x3 lx4 3x3 3x3 3.3
A P I K Q H E D
_
1-4-0
C y
4.4 O J L N M
W:308
3.3 3.3 1x4 3x3 3x3 R: 592
Common Diagonal: 1-3-0 G
1x4
W:308
R: 570
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size-
TO 0.32 4x 2 SP-#2
BC 0.63 4x 2 SP-#2
WB 0.26 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TO Cont. 0- 0- 0 10- B-12
BC Cont. 0- 0- 0 10- 8-12
psf-Ld Dead Live
TO 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TO Fb=1.15 F�1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Boriz-
C 571
F 593
Jt Brg Size Required
C 3.5" 1.5"
F 3.0" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSl-Bnd
----------Top Chords ----------
A -P 0.32 500 C 0.00 0.32
P -L 0.32 1131 C 0.00 0.32
I -K 0.32 1131 C 0.00 0.32
K -Q 0.29 1024 C 0.00 0.29
Q -H 0.28 478 C 0.00 0.28
H -F 0.06 263 C 0.00 0.06
H -F 0.07 263 C 0.00 0.07
F -D 0.03 0 T 0.00 0.03
--------Bottom Chords---------
ALL PLATES ARE MT2020
MiTek® Online Plus-
C -O
0.33
0 T
0.00
0.33
O -J
0.63
936 T
0.10
0.53
J -L
0.54
1131 T
0.14
0.40
L -N
0.40
1131 T
0.18
0.22
N -M
0.46
916 T
0.10
0.36
M -G
0.26
0 T
0.00
0.26
C -A
0.06
309 C
C -A
0.06
309 C
A -O
0.26
666 T
O -P
0.12
606 C
P -J
0.15
395 T
J -I
0.03
193 C
L -K
0.06
170 T
K -N
0.06
331 C
N -Q
0.11
277 T
Q -M
0.12
606 C
M -F
0.26
649 T
G -F
0.08
204 T
TL Defl -0.06" in J -L L/999
LL Defl -0.05" in J -L L/999
DL Defl -0.12" at L L/978
Shear // Grain in C -C 0.32
Plates for each ply each face.
Plate - MT20 20 Gar Gross Area
Plate - MTSH 18 Gar Gross Area
Jt Type Plt Size X Y JSI
I MT20 S.Ox 4.0 Ctr-0.5 0.33
H 14T20 3.Ox 3.0 0.9 Ctr 0.33
F MT20 5.0x 5.0-1.0 0.5 0.56
C MT20 4.Ox 4.0 Ctr 0.5 0.17
O MT20 3.Ox 3.0-0.5 Ctr 0.98
L 14T20 1.Ox 4.0 Ctr 0.5 0.54
M MT20 3.Ox 3.0 0.5 Ctr 0.93
G MT20 1.Ox 4.0 Ctr 0.5 0.65
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and end vertical or
Scale: 0.559" =1'
diagonal web is 1/2".
Provide 2X6 continuous
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-10d(0.131"x3")
nails at truss member(s).
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1131 Lbs
Max tens. force 1131 Lbs
Connector Plate Fabrication
Tolerance = 104
This trues is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EH5251 E 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!'!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
ONhe Plus"' 0 Capynght MTek®1996-2011 Version 28.0.008 Engineemg -Poivaa &W011 10:29:W AM Page 1
Jab
Mark
Quan
Te Span
yp
PI -HI
Left OH
Right OH
Engineering
22443-22444
FL15
3
MS00 101107
10400
0
0
#22443-44- MEL-RY - MORADI
EO 1-4-0
HO 1-4-0
m
0
TCrI
I
1-2-15 11 2-0-0
11 10-0
I 10-0 I
5.5
lx3
F
3x6
3.3
1x4
3.3
3x3
3.3
A
P
I
K
Q
H E D
T
B
1-4-0
_
C
4.4
O
J
LN
M W:308
3x3
3x3
1x4
3.3
3x3 R; 605
Common Diagonal: 1-3-0
G
1x4
W:308
R: 583
BC
- -
5-5-0
1.
m
10-11-7
ALL PLATES ARE
MT2020
Scale: 0.549" =
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.35 4x 2 SP-#2
BC 0.63 4x 2 SP-02
WE 0.27 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 10-11- 7
BC Cont. 0- 0- 0 10-11- 7
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 F�1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 583
P 605
Jt Erg Size Required
C 3.5" 1.5"
F 3.0" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case (a)
Plus 1 DL Load Case(s)
MiTek® Online Plus-
O -J
0.63
964 T
0.10 0.53
J -L
0.55
1182 T
0.14 0.41
L -N
0.46
1182 T
0.19 0.27
N -M
0.47
944 T
0.20 0.37
M -G
0.27
0 T
0.00 0.27
-------------
Webs -------------
C -A
0.06
315 C
C -A
0.06
315 C
A -O
0.27
682 T
O -P
0.13
628 C
P -J
0.17
424 T
J -I
0.04
204 C
L -K
0.06
156 T
K -N
0.06
318 C
N -Q
0.11
277 T
Q -M
0.13
626 C
M -F
0.26
668 T
G -F
0.08
204 T
TL Defl -0.07" in J -L L/999
LL Defl -0.05" in J -L L/999
DL Defl -0.12" at L L/999
Shear // Grain in C -C 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - 14TBH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
I MT20 l.Ox 4.0 Ctr-0.5 0.33
H MT20 3.Ox 3.0 0.9 Ctr 0.33
F MT20 5.Ox 5.0-1.0 0.5 0.57
C MT20 4.Ox 4.0 Ctr 0.5 0.17
O M720 3.Ox 3.0-0.5 Ctr 1.00
L MT20 l.Ox 4.0 Ctr 0.5 0.50
M MT20 3.Ox 3.0 0.5 Ctr 0.96
G MT20 1.Ox 4.0 Ctr 0.5 0.65
Checked for NonConcurrent 200
Lbs Moving Point Load applied
REFER TO ONLINE PLUS GENERAL
at Panel Points and Mid -panel
NOTES AND SYMBOLS SHEET FOR
on BC
ADDITIONAL SPECIFICATIONS.
Membr CSI P Lbs Axl-CSI-Bnd
NOTES:
----------Top Chords----------
Trusses Manufactured by:
A -P 0.32 512 C 0.00 0.32
East Coast Truss
P -I 0.35 1182 C 0.00 0.35
Analysis Conforms To:
I -K 0.35 1182 C 0.00 0.35
FBC2007
K -Q 0.29 1069 C 0.00 0.29
TPI 2002
Q -H 0.29 492 C 0.00 0.29
Design checked for 10 psf non-
* -F 0.06 271 C 0.00 0.06
concurrent LL on BC.
H -F 0.07 271 C 0.00 0.07
Max gap between edge of brg
P -D 0.03 0 T 0.00 0.03
and and vertical or
--------Bottom Chords---------
diagonal web is 1/211.
C -O 0.33 0 T 0.00 0.33
Provide 2X6 continuous
OnMe Plus^' 0 CopyngM MHek0199 2011 Version 29.0.008 EnglneeMg - PoN it 6=011 1&.29:01 AM Page 1
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-10d(0.131"x3")
nails at truss member(s)-
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1182 Lbs
Max tens. force 1182 Lbs
Connector Plate Fabrication
Tolerance = 1016
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. SelimCerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 5 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Job
Mark
Quan
Type
Span ' Pi -Hi
Left OH Right
OH
Engineering
22443-22444
FL16
1 2
M100
140215 10400
0 0
I
#22443-44 - MEL-RY - MORADI
BO 1-4-0
HO 1-4-0
TO
110-15 1 1 2-0-0
1110-0 1 10-0 1
3xB 3.3
3x3
3x3
3x3 3x3
3.3 5E5G
A L S
T
H
C U
D F
T
1-4-0
K
2.3 M R Q
P J
I O
N
4.4 3.3
3x3 1.4
2.3 3x3
4.4 W:308
Common Diagonal: 1-3-0
R: 792
H
lx4
HGR
R: 770
BC - -5-5-0
61
0
m
6
ALL PLATES ARE MT2020
Scale: 0.435" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- -Lumber----
TC 0.66 4x 2 SP-#2
BC 0.93 4x 2 SP-#1
WB 0.39 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 14- 2-15
BC Cont. 0- 0- 0 14- 2-15
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft--1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Soriz-
K 770
E 793
it Brg Size Required
K 3.5" 1.5"
E 3.0" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Cases)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
MSTekO Online P1ueTM
Q -P
0.53
2055 T
0.16 0.37
P -J
0.93
2020 T
0.27 0.66
J -I
0.93
2020 T
0.27 0.66
I -0
0.93
2020 T
0.27 0.66
O -N
0.41
1323 T
0.10 0.31
N -H
0.21
0 T
0.00 0.21
-------------
Webs -------------
K -A
0.08
420 C
K -A
0.08
420 C
A -R
0.39
975 T
A -S
0.1B
894 C
S -Q
0.19
4B5 T
Q -T
0.09
459 C
T -P
0.08
222 T
P -B
0.12
302 T
J -B
0.05
292 C
I -C
0.13
337 T
C -O
0.15
772 C
O -U
0.21
531 T
U -N
0.18
873 C
N -E
0.37
941 T
H -E
0.08
203 T
TL Defl -0.24" in P -J L/672
LL Defl -0.16" in P -J L/999
DL Defl -0.12" at J L/999
Shear // Grain in P -J 0.34
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MISR 18 Ga, Gross Area
it Type Plt Size X Y JSI
A MT20 3.Ox 8.0 1.6-0.5 0.91
U MT20 3:Ox 3.0-0.2 Ctr 0.94
D MT20 3.Ox 3.0 0.9 Ctr 0.33
E MT20 5.Ox 5.0-1.0 0.5 0.81
R MT20 4.Ox 4.0-0.2 0.5 0.96
J MT20 l.Ox 4.0 Ctr 0.5 0.33
I MT20 2.Ox 3.0 0.2 Ctr 0.54
O MT20 3.Ox 3.0 0.2 Ctr 0.94
N MT20 4.Ox 4.0 0.2 0.5 0.95
Membr
CHI
P Lbs
Axl-CSI-Bnd
H MT20 1.0x 4.0 Ctr 0.5 0.65
----------Top Chords----------
A
-S
0.33
732
C 0.00
0.33
REFER TO ONLINE PLUS GENERAL
S
-T
0.36
1725
C 0.03
0.33
NOTES AND SYMBOLS SHEET FOR
T
-B
0.44
2103
C 0.04
0.40
ADDITIONAL SPECIFICATIONS.
B
-C
0.66
2020
C 0.02
0.64
C
-U
0.65
1609
C 0.01
0.64
NOTES:
U
-D
0.32
693
C 0.00
0.32
Trusses Manufactured by:
D
-E
0.07
381
C 0.00
0.07
East Coast Truss
D
-E
0.08
381
C 0.00
0.08
Analysis Conforms To:
E
-G
0.03
0
T 0.00
0.03
FBC2007
--------Bottom
Chords---------
TPI 2002
K
-R
0.22
0
T 0.00
0.22
Design checked for 10 psf non-
*
-Q
0.49
1375
T 0.10
0.39
concurrent LL on BC.
Max gap between edge of brg
and end vertical or
diagonal web is 1/2".
Provide 2X6 continuous
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-l0d(0.13111x3e)
nails at truss---ber(s).
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 2103 Lbs
Max tens. force 2055 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST'TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,PL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 & 19554
190E NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ "BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING &
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online PNs' OCopyright M7ektlgW2011 Veml=28A.006Engineesng-PoNait er1120111029:02AM Pagel
Job
Mark
Quan Type Span
PI-H1
Left OH Right OH
Engineering
22443-22444
17117
1 Mloo 130203
10400
0 0
I
#22443-44 - MEL-RY - MORADI
NO 1-4-0
RO 1-4-0
TC 11 1-2-7 1
1 1-1-0 1 1
2-0-0
1 1 10-0 1 10-0 1
3x4 3.4 3.3 lx4
3x3 3x3 3x3 5x5
EF G
A L R
H H
C T D
T
1-4-0
K
3x3 M Q
F J
L O N H
3x3
3x3 lx4
1x4 3.3 3x3 1x4
U
3
W:308
R: 597
77
Common Diagonal: 1-1-3-0
W:10206
R: 849
HC
- -
5-5-0
m
.v
13-2-3
ALL PLATES ARE
MT2020
Scale: 0.468" = P
Online Plus -- Version 28.0.006
RUN DATE: 26-14AY-11
CSI -Size- ----Lumber----
TC 0.55 4x 2 SP-#2
BC 0.57 4x 2 SP-#2
WB 0.26 4x 2 SP-03
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 13- 2- 3
BC Cont. 0- 0- 0 13- 2- 3
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc=1.10 Ft=1.10'
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
Q 849
E 597
Jt Brg Size Required
Q 14.4" 1.5"
E 3.0" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
* -R 0.55 798 T 0.16 0.39
R -S 0.39 510 C 0.00 0.39
S -B 0.33 1145 C 0.01 0.32
B -C 0.33 1145 C 0.01 0.32
C -1 0.28 1045 C 0.00 0.28
T -D 0.28 484 C 0.00 0.28
D -E 0.06 266 C 0.00 0.06
D -E 0.07 266 C 0.00 0.07
E -G 0.03 0 T 0.00 0.03
--------Bottom Chords---------
lek® Online Plus-
K -Q
0.30
0 T
0.00
0.30
Q -P
0.47
253 T
0.00
0.47
P -U
0.49
918 T
0.05
0.44
J -1
0.57
1145 T
0.14
0.43
I -0
0.41
1145 T
0.20
0.21
O -N
0.49
928 T
0.11
0.38
N -H
0.29
0 T
' 0.00
0.29
K -A
0.13
337 T
K -A
0.13
337 T
A -Q
0.22
1079 C
Q -R
0.21
1012 C
R -P
0.23
577 T
P -S
0.11
566 C
S -U
0.15
374 T
J -B
0.04
200 C
I -C
0.06
154 T
C -O
0.04
236 C
O -T
0.09
235 T
T -N
0.12
615 C
N -E
0.26
657 T
H -E
0.08
204 T
TL Defl -0.07" in J -I L/999
LL Defl -0.05" in J -I L/999
DL Defl -0.12" at I L/999
Shear // Grain in K -K 0,32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 0.98
B MT20 1.0x 4.0 Ctr-0.5 0.33
D MT20 3.Ox 3.0 0.9 Ctr 0.33
E MT20 5.Ox 5.0-1.0 0.5 0.56
P 14720 3.Ox 3.0-0.2 Ctr 0.93
U MT20 2.Ox 3.0-1.0 Ctr 0.90
J MT20 l.Ox 4.0 Ctr 0.5 0.33
I 14T20 1.0x 4.0 Ctr 0.5 0.49
N MT20 3.Ox 3.0 0.5 Ctr 0.94
H MT20 1.Ox 4.0 Ctr 0.5 0.65
REFERTO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Tresses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/2".
Provide 2X6 continuous
strongbacks (on edge) every
10.0 Ft. Fasten to each
truss w/ 3-10d(0.131"x3l')
nails at truss member(s).
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1145 Lbs
Max tens. force 1145 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Selim Cerci, P.E.
5407 Wellezaft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! READ 'SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING S
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus" m Copynghl WTek91996-2011 Version 29A WS En9ineenng - Ponra4 61WO11 10:29:03 AM Page 1
Jab Mark I Quan Type Span Pl-Hl Left OH Right OH Engineering
,22443-22444 M8 1 M100 91101 10400 0 0
#22443-44 - MEL-RY - MORADI
HO 1-4-0 HO 1-4-0
TC j 1 6-1 1
3x4 3x3 3.3 3.3 3.3 3x6
g N O P H C
T
1-4-0
G
2.3 I M L R J
3x3 3x3 3x3 3x3 W:308
F
lx4
W:10206
R: 657
HC9-7- m
0
n
rd o .. .
ALL PLATES ARE MT2020
Scale: 0.610" = V
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.44 4x 2 SP-#2
BC 0.56 4x 2 SP-N2
WE 0.15 4x 2 SP-83
Brace truss as follows:
O.C. From To
TO Cont. 0- 0- 0 9-11- 1
BC Cont. 0- 0- 0 9-11- 1
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fc-1.10 Ft-1.10
BC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
M 657
C 431
Jt Erg Size Required
M 14.4" 1.5"
C 3.0" 1.5"
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Pointe and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-End
----------Top Chords ----------
A -H 0.44 361 T 0.07 0.37
N -O 0.37 392 C 0.00 0.37
O -P 0.25 546 C 0.00 0.25
P -B 0.22 158 C 0.00 0.22
MiTekO Online Plus"
H -C
0.02
87 C
0.00
0.02
B -C
0.02
87 C
0.00
0.02
C -E
0.03
0 T
0.00
0.03
--------Bottom
Chords ---------
G -M
0.29
0 T
0.00
0.29
M -L
0.38
166 T
0.01
0.37
L -K
0.56
595 T
0.07
0.49
K -J
0.50
470 T
0.05
0.45
J -F
0.34
0 T
0.00
0.34
------------- Webs -------------
G -A
0.04
110 T
G -A
0.04
110 T
A -M
0.10
481 C
M -N
0.15
734 C
N -L
0.12
321 T
L -O
0.05
282 C
O -K
0.05
125 T
K -P
0.07
197 T
P -J
0.09
444 C
J -C
0.15
383 T
F -C
0.07
194 T
TL Defl 0.02" in K -J L/999
LL Defl 0.02" in K -J L/999
DL Defl 0.00" at L/999
Shear // Grain in G -G 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MISS 18 Ga, Gross Area
at Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 0.44
B 14T20 3.Ox 3.0 0.7 Ctr 0.33
F MT20 S.Ox 4.0 Ctr 0.5 0.62
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Trues
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 pef non-
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/211.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 734 Lbs
Max tone. force 595 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Carol, P.E.
5407 Wellcraft Dr.
Greenacres. FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 S 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. 111CAUTION!!! READ "BCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING S
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online PNs"OCopynghl MRekSI999-2011Ver ian28.D.0 Engineering-PoWdB 01110:29:04AM Pagel
Jab
22443-22444
Mark
FL19
Quan
1
Type
M100
Span P1-H1 Left
40901 10400 0
OH Right OH
0
Engineering
#22443-44 - MEL-RY
- MORADI
HO 1-4-0
HO 1-4-0
TC,
1 9-9 1
9-8 1
3x4
3x3 3x3
3.6
H
L B
D
1
G
2x3
Ix4 W:308
3x3
3x3
W: 10206
R: 317
BC
- -
-
q
a 1
ALL PLATES ARE MT2020
Scale: 0.893" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size-
TC 0.33 4x 2 SP-#2
BC 0.38 4x 2 SP-#2
WE 0.08 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. O- 0- 0 4- 9- 1
BC Cont. 0- 0- 0 4- 9- 1
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Fb=1.15 Fr-1.10 Ft=1.10
BC Fb=1.10 rc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
K 317
C 251
it: Erg Size Required
K 14.4" 1.5"
C 3.0" 1.5"
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConourrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
* -L 0.33 28 T 0.00 0.33
L -B 0.33 119 C 0.00 0.33
MiTek® Online Plus-
* -C
0.01
65 C
0.00
0.01
B -C
0.01
65.0
0.00
0.01
C -E
0.03
0 T
0.00
0.03
--------Bottom
Chords ---------
* -K
0.26
0 T
0.00
0.26
K -J
0.38
149 T
0.01
0.37
J -F
0.23
0 T
0.00
0.23
G -A
0.01
52 C
G -A
0.01
52 C
A -K
0.00
38 D
K -L
0.05
246 C
L -J
0.02
121 C
J -C
0.08
205 T
F -C
0.08
200 T
TL Defl 0.01" in K -J L/999
LL Defl 0.01" in K -J L/999
DL Defl 0.00" at L/999
Shear // Grain in G -G 0.32
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MT8H 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 0.33
B MT20 3.0x 3.0 0.7 Ctr 0.33
F MT20 1.Ox 4.0 Ctr 0.5 0.64
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
Mar gap between edge of brg
and end vertical or
diagonal web is 1/2".
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 246 Lbs
Max tans. force 205 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,PL 34946
S. Selim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! HEAD "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLACK.
Online Plus^' 0 Copyright MHek41199 2011 Vemion 28.0.006 Engineering-Punrail6 0111029:04 AM Pegs1
Job
Mark
Quan
Type Span PI -Hi
Left OH
Right OH
Engineering
22443-22444
FL20 1
1
M100 50912 10100
0
0
#22443-44 - MEL-RY - MORADI
SO 1-1-0
Bo 1-1-0
a,
m
Tor' 1
5-6-12
N
lx3
2.3
3x4
lx4
3x3
3x4
J
R
T
-X,
�
y
1-1-0
1
Wj
am
MAY
\W
4x4
1
H
D
4.4
4
3x3 lx4
Common Diagonal: 1-3-0
3x3
W:215
R: 307
W:515 Cant:12
R: 307
BC
5-9- lz
B5-9-12
ALL PLATES ARE MT2020
Scale: 0.877" = V
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.35 4x 2 SP-#2
BC 0.41 4x 2 SP-#2
WB 0.19 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. 0- 0- 0 5- 9-12
BC Cont. 0- 0- 0 5- 9-12
psf-Ld Dead Live
TO 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TO Fb=1.15 Fc=1.10 Ft=1.10
BC Fb=1.10 Fr=1.10 Ft=1.10
Total Load Reactions (Lbs)
it Down Uplift Horiz-
C 307
F 307
it: Erg Size Required
C 2.9" 1.5"
F 5.9" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbs Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
----------Top Chords ----------
A -J 0.21 399 C 0.00 0.21
MiTekO Online Plus-
* -K
0.21
399 C
0.00 0.21
K -D
0.35
280 C
0.00 0.35
--------Bottom
Chords ---------
C -I
0.27
0 T
0.00 0.27
I -H
0.35
399 T
0.07 0.28
H -G
0.41
399 T
0.05 0.36
G -F
0.27.
0 T
0.00 0.27
-------------
Webs -------------
C -A
0.03
177 C
C -A
0.03
177 C
A -I
0.19
480 T
I -J
0.03
161 C
H -K
0.03
116 C
K -G
0.03
190 C
G -D
0.13
341 T
F -D
0.03
167 C
F -D
0.03
167 C
TL Defl -0.03" in H -G L/999
LL Defl -0.02" in H -G L/999
DL Defl 0.00" at L/999
Shear // Grain in C -C 0.33
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MISS 18 Ga, Grose Area
it Type Plt Size X Y JSI
A MT20 3.Ox 4.0-0.5 Ctr 0.89
J MT20 1.Ox 4.0 Ctr-0.5 0.33
D MT20 3.Ox 4.0 0.5 Ctr 0.63
C MT20 4.Ox 4.0 Ctr 0.5 0.16
H MT20 1.Ox 4.0 Ctr 0.5 0.33
F MT20 4.Ox 4.0 1.2 0.5 0.13
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Con£oxms To:
FBC20Q7
TPI 2002
Design checked for 10 psf non -
concurrent LL on BC.
This truss must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 399 Lbs
Max tans. force 480 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 S 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !!!CAUTION!!! HEAD "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus^ 0 Copyright MOeM 1BW2011 Version 28.0.006 Engines" -Portrait 6=011 10:29.05 AM Pagel
Job I Marx I Quan Type Span P1-H1 Left OH Right OH Engineering
22443-22444 FL21 3 M100 100500 10400 0 0
1 #22443-44 - MEL-RY - MORADI
To
T
SO 1-4-0 NO 1-4-0
m
0
5.5 1x3
C
3x3 3x3 3x3 3x3 3x3 lx4
A H D O P Q I E
G N M L K J 2-
2-G4 3x3 3x3 3.3 3.3 lx4
W:308 Common Diagonal: 1-3-0
R: 562
Cant:2- 4
W:508
R: 560
-
0
rt
v 10-5-0-
ALL PLATES ARE MT2020
Scale: 0.568" = 1'
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CSI -Size- ----Lumber----
TC 0.31 4x 2 SP-#2
BC 0.61 4x 2 SP-#2
WB 0.24 4x 2 SP-#3
Brace trues as follows:
O.C. From To
TC Cont. 0- 0- 0 10- 5- 0
BC Cont. 0- 0- 0 10- 5- 0
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+BC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TO Fb=1.15 Fc=1.10 Ft=1.10
HC Fb=1.10 Fc=1.10 Ft=1.10
Total Load Reactions (Lbs)
Jt Down Uplift Horiz-
C 562
F 560
Jt Brg Size Required
C 3.0" 1.5"
F 5.5" 1.5n
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lba Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
---------- Top Chords ----_-_--_
A -C 0.03 0 T 0.00 0.03
C -D 0.06 248 C 0.00 0.06
C -D 0.09 248 C 0.00 0.06
MiTek® Online Plus-
D -O
0.30
451 C
0.00
O -P
0.31
974 C
0.01
P -Q
0.25
906 C
0.00
Q -L
0.23
277 C
0.00
I -E
0.14
0 T
0.00
--------Bottom
Chords----
* -N
0.30
0 T
0.00
N -M
0.47
855 T
0.09
M -L
0.61
1068 T
0.12
L -K
0.54
716 T
0.08
K -J
0.32
0 T
0.00
J -F
0.12
0 T
0.00
G -C
0.08
215 T
C -N
0.24
612 T
N -O
0.11
563 C
0 -M
0.09
231 T
M -P
0.03
130 C
P -L
0.04
225 C
L -Q
0.11
274 T
Q -K
0.12
606 C
K -I
0.19
494 T
J -I
0.12
639 C
F -E
0.04
Ill T
0.30
0.30
0.25
0.23
0.14
0.30
0.38
0.49
0.46
0.32
0.12
TL Defl -0.03" in M -L L/999
LL Defl -0.02" in M -L L/999
DL Defl -0.12" at M L/914
Shear // Grain in D -O 0.24
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MTSH 18 Ga, Gross Area
Jt Type Plt Size X Y JSI
C MT20 5.Ox 5.0 1.0 0.5 0.52
D MT20 3.Ox 3.0-0.9 Ctr 0.33
E MT20 S.Ox 4.0 Ctr-0.5 0.35
G MT20 1.Ox 4.0 Ctr 0.5 0.69
N MT20 3.Ox 3.0-0.2 Ctr 0.97
J MT20 S.Ox 4.0 Ctr 0.5 0.43
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Trusses Manufactured by:
East Coast Truss
Analysis Conforms To:
FBC2007
TPI 2002
Design checked for 10 pelf non -
concurrent LL on SC.
Max gap between edge of brg
and end vertical or
diagonal web is 1/2".
This truss most be installed
as shown. It cannot be
installed upside-down.
Max comp. force 974 Lbs
Max tens. force 1068 Lbs
Connector Plate Fabrication
Tolerance = 10%
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 ST.LUCIE BLVD.
FORT PIERCE,FL 34946
S. Salim Cerci, P.E.
5407 Wellcraft Dr.
Greenacres, FL.33463
MAURICE A. SHASHOUA,
P.E.#EB5251 6 19554
190E NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !IICAUTIONI!! READ "SCSI-B1
SUMMARY SHEET" BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-BEARING BLOCK.
Online Plus"' OOOPy49M MTeM 1906-2011 Verebn 2aO.009 Engineetln9-Polud 6=01110:29:05AM Pagel
Job
Mark
Quan Type
Span P1-H1
Left OH Right OH
Engineering
2244,.3-22444
FL22
3 M100
100500 10400
0 0
#22443-44 - MEL-RY - MORADI
HO 1-4-0
BO 1-4-0
m
0
m
0
TC I^ I
10-0-8
;1
5.5
lx3
C
3x3
3x3 1x4
lx4
3x3 4x4
A B
D
M N
O
P E
T
1-a-o
I
I ��
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size-----Lvmber----
TC 0.33 4x 2 3P-#2
BC 0.65 4x 2 SP-#2
WB 0.25 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. O- 0- 0 10- 5- 0
BC. Cont. 0- 0- 0 10- 5- 0
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+HC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Pb=1.15 F�1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Fta1.10
Total Load Reactions (Lbe)
Jt Down Uplift Horiz-
C 576
F 554
Jt Brg Size Required
C 3.0" 1.5"
F 5.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbe Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
__________Top Chords ----------
A -C 0.03 0 T 0.00 0.03
C -D 0.06 253 C 0.00 0.06
C -D 0.07 253 C 0.00 0.07
Online Plus -- Version 28.0.006
RUN DATE: 26-MAY-11
CHI -Size-----Lvmber----
TC 0.33 4x 2 3P-#2
BC 0.65 4x 2 SP-#2
WB 0.25 4x 2 SP-#3
Brace truss as follows:
O.C. From To
TC Cont. O- 0- 0 10- 5- 0
BC. Cont. 0- 0- 0 10- 5- 0
psf-Ld Dead Live
TC 10.0 40.0
BC 5.0 0.0
TC+HC 15.0 40.0
Total 55.0 Spacing 24.0"
Lumber Duration Factor 1.00
Plate Duration Factor 1.00
TC Pb=1.15 F�1.10 Ft=1.10
BC Fb=1.10 Fc=1.10 Fta1.10
Total Load Reactions (Lbe)
Jt Down Uplift Horiz-
C 576
F 554
Jt Brg Size Required
C 3.0" 1.5"
F 5.5" 1.5"
Plus 2 Unbalanced Load Cases
Plus 1 UBC LL Load Case(s)
Plus 1 DL Load Case(s)
Checked for NonConcurrent 200
Lbe Moving Point Load applied
at Panel Points and Mid -panel
on BC
Membr CSI P Lbs Axl-CSI-Bnd
__________Top Chords ----------
A -C 0.03 0 T 0.00 0.03
C -D 0.06 253 C 0.00 0.06
C -D 0.07 253 C 0.00 0.07
MiTek® Online Plus"
D -M
0.28
461 C
0.00
0.28
M -N
0.31
1064 C
0.00
0.31
N -0
0.31
1064 C
0.00
0.31
O -P
0.33
1064 C
0.00
0.33
P -E
0.33
483 C
0.00
0.33
--------Bottom
Chords
---------
* -L
0.34
0 T
0.00
0.34
L -X
0.63
874 T
0.09
0.54
K -J
0.53
1064 T
0.13
0.40
J -I
0.65
898 T
0.10
0.55
I -F
0.34
0 T
0.00
0.34
_____________Webs_____________
G -C
0.08
215 T
C -L
0.25
625 T
L -M
0.11
576 C
M -R
0.15
377 T
K -N
0.03
192 C
J -O
0.03
183 C
J -P
0.14
361 T
P -I
0.12
578 C
2 -E
0.25
643 T
F -E
0.05
300 C
F -E
0.05
300 C
TL Defl -0.06" in J -I L/999
LL Defl -0.05" in J -I L/999
DL Defl -0.12" at J L/920
Shear // Grain in F -F 0.33
Plates for each ply each face.
Plate - MT20 20 Ga, Gross Area
Plate - MTBH 18 Ga, Gxoea Area
Jt Type Plt Size X Y J3I
C MT20 5.Ox 5.0 1.0 0.5 0.54
D MT20 3.Ox 3.0-0.9 Ctr 0.33
N MT20 1.Ox 4.0 Ctr-0.5 0.33
O MT20 1.Ox 4.0 Ctr-0.5 0.33
E MT20 4.Ox 4.0 0.5-0.5 0.99
G MT20 1.Ox 4.0 Ctr 0.5 0.68
L MT20 3.Ox 3.0-0.2 Ctr 0.99
2 MT20 3.Ox 3.0 0.5 Ctr 0.94
F MT20 d.Ox 4.0 1.2 0.5 0.13
REFER TO ONLINE PLUS GENERAL
NOTES AND SYMBOLS SHEET FOR
ADDITIONAL SPECIFICATIONS.
NOTES:
Truesea Manufactured by:
East Coast Trues
Analysis Conforms To:
FHC2007
TPI 2002
Design checked for 10 psE non -
concurrent LL on BC.
Max gap between edge of brg
and and vertical or
diagonal web is 1/2".
This trues must be installed
as shown. It cannot be
installed upside-down.
Max comp. force 1064 Lbe
Max tens. Force 1064 Lbs
Connector Plate Fabrication
Tolerance SO$
This truss is designed for a
creep factor of 1.5 which
is used to calculate total
load deflection.
FABRICATOR NOTES:
1. EAST COAST TRUSS
5285 9T.LUCIE BLVD.
FORT PIERCE,FL 34946
S.
9elim Cerci, P.E.
5407 WellcraEt Dr.
Gxeenacrea, FL.33463
MAURICE A. SHASHOUA,
P.E.#EH5251 6 19554
1908 NW 112 AVE.
CORAL SPRINGS, FL 33071
2. !IICADTIDN!II READ "BCSI-81
SUMMARY SHEET- BEFORE
HANDLING , INSTALLING 6
BRACING TRUSSES.
3. SEE ATTACHED DETAIL SHEET
FOR: 1-JACK NAILS.
2-TBRACE. 3-HEARING BLOCK.
OnMe Plus^` ®Capy:igm MRek®198fi-2017 Varslon 76.0.006 E:gNeaMg- Poitrail 6R11011 10:29:06 AM Page 1