HomeMy WebLinkAboutPOOL PLANSLOCATION OF GFI RECEPTACLE TO BE
DETERMINED IN FIELD PER NEC 680
I POOL SPECIFICATIONS I
l MAXIMUM WIDTH 19 MAXIMUM LENGTH 35
MINIMUM DEPTH 3.%, MAXIMUM DEPTH 6'
POOL 464 SQ. FT. X 89 LN. FT.
DECK 418 SQ. FT.
EXISTING DECK NA
_ _____ PER PLAN
CHLORINATOR PENTAIR INTELLICHLOR
HEATER NA
FILTER CARTRIDGE CC1SO
MISC. SUN DECK WITH BUBBLER &
DIEVAN RESIDENCE
6 X 6 WATERLINE TILE GP82348B3 SHEET TILE
2 X 6 STEP TILE GP82348B3
OVER POUR YES
HAND HOLDS IHA
GEM FINISH BLACK JEWEL (LIFETIME)
BABY BARRIER BLACK
DECKING BIRCH GRAY
PENTAIR INTELLICHLOR SALT GENERATOR
1V 1" 1'IJ 'ILL
ADDHION
M......1�R�.._...q<q,.,y�f.,..-_••�;...�,......,...�„p....r,.,�,�,.,TAR;.:........�..._...�gy,..-.....may-. �.ie71p0�"v-....•*.fanoR.--• _-�avaTA+ir•..:.,.^.mxv^"��^+,......-....s,.... ,,,,u�,p•, __me......-.aarr-�eR.'.-_*em^Tn9oTt�r=........,,.,q�.r.. ..-�esr-•_4—._A'JR,... _�,... ,yAr,.- "RT4..
SCANNED
- *gym ByP �
St. Lucie County
MOTOR H.P.3 HP VAR MOTOR H.P. SPA HA
J BOX INCL TRANSFORMER INCL TIME CLOCK INCL
NA
1 ELECTRICAL HOOKUP PAYUCK 1
1 TERMITE TREATMENT INCL. 1
I OWNERS HEREBY ASSUME AND AGREE TO THE
PROVISIONS OF THE CONTRACT FOR POOL
CONSTRUCTION, AND APPROVE THESE PLANS
WHICH ARE MADE APART OF THAT CONTRACT
OWNERS SIGNATURE
ADDRESS: 7203 S. INDIAN RIVER DRIVE
FT. PIERCE, FL.34982
AGENT SIGNATURE: SONJA CORBETT
OOLS
by
GRE
DEV,N RESIDENCE
DA & ALLISON
A BARRIER OR ALARM IS NOT SUBSTITUTE FOR PARENTAL SUPERVISION. NO CHILD
SHOULD BE LEFT UNATTENDED. PARENTS SHOULD KNOW THAT ADULT SUPERVISION IS THE
ONLY WAY TO PREVENT AN ACCIDENT. THEY SHOULD MAINTAIN CONSTANT EYE CONTACT
WITH THE CHILDREN WHENEVER THEY ARE NEAR, OR COULD GET NEAR ANY BODY OF
WATER. UNFORTUNATELY, MOST ACCIDENTS OCCUR WHEN THERE IS A LAPSE IN
SUPERVISION EVEN FOR A SMALL TIME. NEVERTHELESS, PARENTS SHOULD BE AWARE THAT
ANY BODY OF WATER POSES A RISK, ESPECIALLY FOR CHILDREN UNDER 5 YEARS OF AGE.
POOLS BY GREG CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH OR
INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM WHEN USED BY THE
CUSTOMER, FOR ANY REASON BEYOND ITS CONTROL UNDER ANY CIRCUMSTANCES, FOR
ANY REASON WHATSOEVER. THE CUSTOMER ASSUMES ALL RISKS DIRECTLY OR INDIRECTLY
RELATED TO MALFUNCTIONING OR FAILURE OF BARRIER OR ALARM. POOLS BY GREG, INC.
MAKES NO CLAIM WHATSOEVER TO THE DIFFERENCE OF THESE PRODUCTS
RULES FOR POOLS
> INSTRUCT SABYSITTERS ABOUT POTENTIAL POOL HAZARDS TO YOUNG CHILDREN
AND ABOUT THE USE OF PROTECTIVE DEVICES SUCH AS DOOR ALARMS AND LATCHES
EM PHASRE THE NEED FOR CONSTANT SUPERVISION.
> DURING SOCIAL GATHERINGS AT OR NEAR A POOL APPOINT A DESIGNATED WATCHER
TO PROTECT YOUNG CHILDREN FROM POOL ACCIDENTS. ADULTS MAY TAKE TURNS
BEING THE WATCHER OTHERWISE, ADULTS MAY BECOME PREOCCUPIED AND ASSUME
SOMEONE ELSE IS WATCHING THE CHILDREN.
v IF CHILD IS MISSING, CHECK THE POOL FIRST. SECONDS COUNT IN PREVENTING
D
DEATH OR DISABILITY. GO TO THE EDGE OF THE POOL AND SCAN THE ENTIRE POOL
BOTTOM AND SURFACE, AS WELL AS THE POOL AREA.
ti DO NOT ALLOW A YOUNG CHILD ON THE POOL WITHOUT AN ADULT.
v DO NOT CONSIDER YOUNG CHILDREN TO BE DROWN -PROOF BECAUSE THEY HAVE HAC
^
SWIMMING LESSONS OR ARE WEARING A LIFE JACKET.
I
v LEARN CPR, BABYSITTERSAND OTHER CARETAKERS, SUCH AS GRANDPARENTS AND
m
OTHER SIBLINGS, SHOULD ALSO KNOW CPR
v KEEP RESCUE EQUIPMENT BY THE POOL BE SURE TELEPHONE IS POOL SIDE WITH
EMERGENCY NUMBERS POSTED NEARBY.
REMOVED TOYS FROM IN AND AROUND THE POOL WHEN IT IS NOT IN USE. TOYS CAN
p
ATTRACT YOUNG CHILDREN TO THE POOL.
a NEVER PROP OPEN THE GATE TO A POOL.
> NO RUNNING, PUSHING, WRESTLING OR DISTURBANCE IN THE POOL AREA. NO
CHEWING GUM PERMITTED IN THE POOL AREA )RED CROSS SAFETY SUGGESTION FOR
THE PREVENTION OF CHOKING).
> DON'T LET LONG HAIR GET NEAR A POOL OUTLET. THE SUCTION CAN CAUSE HAIR OR
BODY ENTRAPMENT AND DROWNING.
> HAVE A FIRST AID KITAT POOL SIDE.
v NEVER SWIM ALONE.
v NO JUMPING OR DIVING IN THE SHALLOW AREA OF THE POOL.
> DON'T ALLOW CHILDREN TO PLAY AS THOUGH THE ARE DROWNING, A FALSE ALARM
MIGHT DELAY A RESCUE IN THE EVENT OF A REAL EMERGENCY.
> WHEN DIVING, ALWAYS ENTER THE WATER WITH YOUR ARMS EKTENDTD FIRMLY
OVERHEAD AND KEEP YOUR HANDS TOGETHER TO PROTECT YOUR HEAD. DIVING INTO
SHALLOW WATER CAN RESULT IN CERVICAL SPINE INJURIES CAUSING PERMANENT
PARALYSIS. NEVER DIVE INTO AN ABOVE GROUND POOL.
v AVOID THE USE OF ALCOHOL On OTHER DRUGS AROUND WATER
1:1--+ ' I 'YyT'R. 11 m:;'
HARVEY E. KOEHNEN
rofessional Engineer PE-32831
7206 Elyse Circle
Port St. Lucie, FL 34962-3212
Fax (77-2) 469-3035
wz-02�5
NOTE: REMOVE GRATE a 14• PER FT MIN SLOPE
WELL POINT RUG FROM MAN OEAIIUR, aW llE
DRAIN a ATTACH AUX. PUMP an UR AP TLE
i. ..'
LINE WHEN EMPTYING POOL MARE MPa(98E `. [ • ,y_"
6"x6" TILE /Ism / ♦� i
GRATE SHALL 4" SLAB � -.. t�■ 1jL. ,IM®Y,
—Water Velocity —Max 8ft Sec as BE SECURED IN INTERIOR 2500 FIBER MIX
/ pet FBC 2010—R4101 6 3 PLACE SO FINISH a>h TYP. WALL —Pool Barrier to Comply with FBC 2010—R4101 THAT TOOLS
ARE REQUIRED
—Skimmers comply with FBC 2010a
p V f?41 0 1.21.1 FOR REMOVAL STEEL—TEX FORM �� f�
— Equipment Foundation 3'x7' cone 6"
slab min 3 5" thick pour in place OR KRAFT WALL i(
TYP. ':
TRENCH DRAIN FLOOR tT 13 0 12° O.C.B.W.
" NOTE: FOR DEPTHS
TREADED Y` GREATER THAN 6' ADD
PLUG .'... ' { (1)3 COVE BAR 06" O.C. C _ )j �°�� INC
GRAVEL B TO PUMP �. 1
TYP. WALL SECTION & WELL POINT
(NO SCALE)
DECK I ROW OF WATERLINE 11LE
WHEN PROVIDED PRESSURE GAUGES INSTALLED ON FILTER
SHALL BE AT 20" MAX CHLORINATOR
BELOW THE FILTER PUMP FOR FINAL INSPECTION + ++ wATERUNE + ++
WATERLINE uMPsfWR/MN�R & 4 -0 6'—U++ MAX 6" HICKHE
3 -g LIGHT
uaNs —T-1 I SLOPE
TER
Q3 STEEL 012° 0/C E.W. IT" EA 11"
is"
o SY011LOPF FLOOR SLOPES
Vacuum In H X 1.13 Pressure PSI % 2.31 ME A[.OW m rrya emu
( g) (PSI) mow sRosLOnE o�cR""AaA nL REASONABLY MO
Feet Of Head Feet Of Head NOT EXCEED 1 FaaT IN T W COMPLY Mm ARnnE< sa 1
�' �2 C�FANER 1.LNE lYAl1 5_6.3
Vacuum Head + Pressure Head c+'ELO -I
= Total Dynamic Head 16'-0" 19'-0"
JJ V
SWIMOUTS PIPING SCHEMATIC TYPICAL SECTION THRU POOL
(NO SCALE) (NO SCALE)
CUSTOM MOLDED PRODUCTS INC.
HYDRO —STATIC RELIEF CMP 25506-32X VGD
DEVICE INSTALLED IN SINGIF CHANNEL OUTLET COMPLIANT 32" CHANNEL DRAIN
AREAS THAT EXCEED V PER FRC4101.6.6
WATER TABLE IN SHELL
COMPUENT W/107.2.1 OF THE
2010 FLORIDA BUSING CODE
TRENCH DRAIN
32" CHANNEL DRAIN AND SUMP _ 2.5.+'
25506-320—OM -
1.5" VENT *THREE 2" SOCKET x 2.5° SPIGOT PORTS
"DEBRIS GUARD INCLUDED
rO GRAM BED *38.79in' OPEN AREA
*IAMPO DSTED FLOW RATES
*WHITE PVC BODY
MAIN DRAIN *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP
The maximum flow rating for this suction fitting with the center port plugged and outer ports
open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor)
and 192 GPM (Well) when using 2" plumbing. The maximum flow rating far this suction
POOL DETAIL fining with the outer parts plugged and the center port open is 200 GPM (floor) and 168 GPM
(NO SCALE) (wail) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (nil) when using 2" plumbing.
Pipe Size
6 fps
8fps
1'
16
gpm
0.14'
21
gpm
0,23'
1,5'
37
gpm
0.08'
50
gpm
0,14'
2'
62
gpm
0,06'
82
0,10'
2,5'
88
gpm
0.05'
117
gpm
0.0or
2_
3'
136
gpm
0.04'
181
gpm
0,07'
4'
234
gpm
0,03'
313
gpm
0.05'
6'
534
gpm
0.02'
712
gpm
0,03'
OUTSIDE ANGLE OF REPOSE
6' AND FURTHER 14' THICK WALLS EBAR RENAR D.C.E O.C. EACH WAY Determine System Flow Rate: Minimum Flow Rate Required: 35 m per skimmer
3' TO 8' — 6° THICK WALLS W/�3 RF9AR 912" C. EACH WAY - '" Y 9 � 9P
0' TO 3' — 8° THICK WAILS W/#3 REB•R e12' O.C. EACH WAY `� 1. Calculate Pool Volume: _ XXX ___ft__M _x 7.48(gal/Ft) _ XXX _—gal
_.� (Turnover Minutes) of Flow Rate) (Feature Flow Rate) (System Flaw Rate)
y, (Surface Area) (Average Depth) Volume gallons)
9 it. . A e -- -- —
ge p 'n ns
2. Determine Flow Rate: _ XXX gal / XXX _ XXX __+_ XXX ___=___XXX
'�"""` ;�;✓P� r �`�'&� - (Volume) i es)s (Po te) (Fe te) (S st
s tL Determine Pipe Sizes:
Trunk Piping to be_L5 _inch to keep velocity ® 8 fps max. at_117 gpm Maximum System Flow Rate.
3 ft. Return Piping to be�,�_inch to keep velocity It 8 fps max. at 117 -gpm Maximum System Flow Rate.
Main Drain Cover(____SEE A80VE------) System Flow Rate must not exceed approved cover flaw rote.
�:. ter• (Make and Model) See Engineering Page for Drain Configuration
d Q Q
� 3 3
F�
IXOAYAnON INTO THE ANGLE of REPOSE Is ALLOWABLE PRowDED: Pump Model PENTAIR INTELLIFLO VS-3050 H.P. 3
(,j✓�' ' SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE Total H.P=H.P.xwi icefaW.I H.p.ormoremustbe2speedorvadeblespead
SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT Filter Make PENTAIR C&C Size 150
* r {NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES Filter min. area based on 6hr.mmovMflow rate el.
COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED P� 9 136D min. = Flow Rate
PRIOR TO THE POURING OF THE PATIO DMde G.P.M. by Cartridge=.375orSsnd=ISOr D.E.=2
Time Controller make ON PUMP Model ------
Controls must operates minimum of two speeds
POOL PATIO The higher speed orenMeisnot toMond anenormal cycle or24has, whichaverblWes
MISC. NOTES WATER LEVEL '.'.r..'•:'t:.•i.::'._: :'::'..: 'r.C. k:
1. ALL STEPS AND SIMMOUT BENCH EDGES
WILL HAVE 24 CMnLE BORDER OF OPPOSITE .`A, : . • -
COLOR OF GEM FINISH FOR VISIBILITY
2. HANDHOLD TO BE INSTALLED ARE WHERE •;
DECK RAISED +6" ABOVE POOL g ` t.; FROM THESE PLANS AND ALL PROPOSED
ONSK
10" MIN
O0 'X t. SUPPLY ARE
SUBJECT TO,ANY
:. coNou"T REQUIRED6YFIELD.INSPECTORSTNA
MpY SE NECESSARY IN ORDER TO
__ _
- LE CODES:
UNDERWATER LIGHT NICHE ' COMPLY WITH ALL, ApPL�CA9 DESIGNED FOR: @rFESSIONALIWGI E. xoP&3Z 3
UGHT u:t— HtOP0SiL2DS ELY$fi CIRCLEP&32831
STEP DETAILS �A�LrS,BYGREG PORT STLUCT8,PL34952
APPROVED
r T. TREAD IS MIN OF 10° MCP. NICHEENCASED
NGUNITE � GROUND CLAMP DEVf917 RESIDENCE
M2)489"3035fax
2. RISER NOT GREATER THAN
ARE 12" EXCEPT IF •;'- : `r " A�L`f-
Ma RE THAN (3) TRESS ARE USED CONTINUOUS BOND WIRE 7302 S. III M RNER DR.
3. ALL STEPS TO BE SOLID GUNITE 4000 P.S.I.
POOL FINISH ''"' COMMON TO POOL STEEL,
STEPS RAILS & EQUIPMENT FP PIERCE, FL �f
(NO SCALE) UNDERWATER LIGHT DETAIL
(NO SCALE) OP/05/44
A
u
__ .
POOL 464 SQ. FT, X 89 LN. FT.
nFr_K 418 SQ. FT.
EXISTING DECK NA
I+^^.. D PER PLAN
CHLORINATOR PENTAIR INTELLICHLOR
HEATER NA
FILTER CARTRIDGE CC150
misc. SUN DECK WITH BUBBLER &
1 L
DIVAN RESIDENCE
I rC SAvC-P- -P ooL ir0c
LOCATION OF GFI RECEPTACLE TO BE
DETERMINED IN FIELD PER NEC 680
6 X 6 WATERLINE TILE GP82348B3 SHEET TILE
2 X 6 STEP TILE GP82348B3
OVER POUR YES
HAND HOLDS NA
GEM FINISH BLACK JEWEL (LIFETIME)
BABY BARRIER BLACK
DECKING BIRCH GRAY
PENTAIR INTELLICHLOR SALT GENERATOR
NIc4F X 3(c t)LE-- SI ACINF
L ,
Copes'pRIc_Lz-D cN h— I APPRuPAIATL�Ly �" )n, FRLI-i,
a ^^L^lV 1'U 1 UIIL'
r�
POOL SPECIFICATIONS
MAXIMUM WIDTH 19 MAXIMUM LENGTH
MINIMUM DEPTH 3•'/,+ MAYIMIIM LICDTY
NA
K INCL
1—.RETURNS POOL: 4 RETURNS SPA NA —�
I ELECTRICAL HOOKUP PAYUCK '
e7
OWNERS HEREBY ASSUME AND AGREE TO THE
PROVISIONS OF THE CONTRACT FOR POOL
CONSTRUCTION, AND APPROVE THESE PLANS
WHICH ARE MADE APART OF THAT CONTRACT
OWNERS SIGNATURE
ADDRESS: 7203 S. INDIAN RIVER DRIVE
FT. PIERCE, FL.34982
AGFTIJT STGNATURE: .S:' NTA C,*)rZ' ;r
OOLS
by
GRE
DEVAN RESIDENCE
DAN & ALLISON
A BARRIER OR ALARM IS NOT A SUBSTITUTE FOR PARENTAL SUPERVISION. NO CHILD
SHOULD BE LEFT UNATTENDED. PARENTS SHOULD KNOW THAT ADULT SUPERVISION IS THE
ONLY WAY TO PREVENT AN ACCIDENT. THEY SHOULD MAINTAIN CONSTANT EYE CONTACT
WITH THE CHILDREN WHENEVER THEY ARE NEAR, OR COULD GET NEAR ANY BODY OF
WATER, UNFORTUNATELY, MOST ACCIDENTS OCCUR WHEN THERE IS A LAPSE IN
SUPERVISION EVEN FOR A SMALL TIME. NEVERTHELESS, PARENTS SHOULD BE AWARE THAT
ANY BODY OF WATER POSES A RISK, ESPECIALLY FOR CHILDREN UNDER 5 YEARS OF AGE.
POOLS BY GREG CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH OR
INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM WHEN USED BY THE
CUSTOMER, FOR ANY REASON BEYOND ITS CONTROL UNDER ANY CIRCUMSTANCES, FOR
ANY REASON WHATSOEVER. THE CUSTOMER ASSUMES ALL RISKS DIRECTLY OR INDIRECTLY
RELATED TO MALFUNCTIONING OR FAILURE OF BARRIER OR ALARM, POOLS BY GREG, INC.
MAKES NO CLAIM WHATSOEVER TO THE DIFFERENCE OF THESE PRODUCTS
RULES FOR POOLS
➢ INSTRUCT BABY-SITTERS ABOUT POTENTIAL POOL HAZARDS TO YOUNG CHILDREN
AND ABOUT THE USE OF PROTECTIVE DEVICES SUCH AS DOOR ALARMS AND LATCHES,
EMPHASIZE THE NEED FOR CONSTANT SUPERVISION.
➢ DURING SOCIAL GATHERINGS AT OR NEAR POOL APPOINT A DESIGNATED WATCHER
TO PROTECT YOUNG CHILDREN FROM POOL ACCIDENTS. ADULTS MAY TAKE TURNS
BEING THE WATCHER OTHERWISE, ADULTS MAY BECOME PREOCCUPIED AND ASSUME
SOMEONE ELSE IS WATCHING THE CHILDREN.
➢ IFA CHILD IS MISSING, CHECK THE POOL FIRST. SECONDS COUNT IN PREVENTING
DEATH OR DISABILITY. GO TO THE EDGE OF THE POOL AND SCAN THE ENTIRE POOL
BOTTOM AIND SURFACE, AS WELL AS THE POOL AREA.
➢ DO NOT ALLOW A YOUNG CHILD ON THE POOL WITHOUT AN ADULT.
➢ DO NOT CONSIDER YOUNG CHILDREN TO BE DROWN -PROOF BECAUSE THEY HAVE HAD
SWIMMING LESSONS OR ARE WEARING A LIFE JACKET.
➢ LEARN CPR, BABYSITTERSAND OTHER CARETAKERS, SUCH AS GRANDPARENTS AND
OTHER SIBLINGS, SHOULD ALSO KNOW CPR
> KEEP RESCUE EQUIPMENT BY THE POOL BE SURE A TELEPHONE IS POOL SIDE WITH
EMERGENCY NUMBERS POSTED NEARBY.
➢ REMOVED TOYS FROM IN AND AROUND THE POOL WHEN IT 15 NOT IN USE. TOYS CAN
ATTRACT YOUNG CHILDREN TO THE POOL.
➢ NEVER PROP OPEN THE GATE TO A POOL.
➢ NO RUNNING, PUSHING, WRESTLING OR DISTURBANCE IN THE POOL AREA. NO
CHEWING GUM PERMITTED IN THE POOL AREA (RED CROSS SAFETY SUGGESTION FOR
THE PREVENTION OF CHOKING).
DON'T LET LONG HAIR GET NEAR A POOL OUTLET. THE SUCTION CAN CAUSE HAIR OR
BODY ENTRAPMENT AND DROWNING.
➢ HAVE A FIRST AID KITAT POOL SIDE.
➢ NEVER SWIM ALONE.
➢ NO JUMPING OR DIVING IN THE SHALLOW AREA OF THE POOL
➢ DON'T ALLOW CHILDREN TO PLAY AS THOUGH THE ARE DROWNING. A FALSE ALARM
MIGHT DELAY A RESCUE IN THE EVENT OF A REAL EMERGENCY.
➢ WHEN DIVING, ALWAYS ENTER THE WATER WITH YOUR ARMS EXTENDTD FIRMLY
OVERHEAD AND KEEP YOUR HANDS TOGETHER TO PROTECT YOUR HEAD. DIVING INTO
SHALLOW WATER CAN RESULT IN CERVICAL SPINE INJURIES CAUSING PERMANENT
PARALYSIS. NEVER DIVE INTO AN ABOVE GROUND POOL.
VOID THE USE OF ALCOHOL OR OTHER DRUGS AROUND WATER.
SLANNED