HomeMy WebLinkAboutPOOL PLANSLOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 I POOL SPECIFICATIONS I l MAXIMUM WIDTH 19 MAXIMUM LENGTH 35 MINIMUM DEPTH 3.%, MAXIMUM DEPTH 6' POOL 464 SQ. FT. X 89 LN. FT. DECK 418 SQ. FT. EXISTING DECK NA _ _____ PER PLAN CHLORINATOR PENTAIR INTELLICHLOR HEATER NA FILTER CARTRIDGE CC1SO MISC. SUN DECK WITH BUBBLER & DIEVAN RESIDENCE 6 X 6 WATERLINE TILE GP82348B3 SHEET TILE 2 X 6 STEP TILE GP82348B3 OVER POUR YES HAND HOLDS IHA GEM FINISH BLACK JEWEL (LIFETIME) BABY BARRIER BLACK DECKING BIRCH GRAY PENTAIR INTELLICHLOR SALT GENERATOR 1V 1" 1'IJ 'ILL ADDHION M......1�R�.._...q<q,.,y�f.,..-_••�;...�,......,...�„p....r,.,�,�,.,TAR;.:........�..._...�gy,..-.....may-. �.ie71p0�"v-....•*.fanoR.--• _-�avaTA+ir•..:.,.^.mxv^"��^+,......-....s,.... ,,,,u�,p•, __me......-.aarr-�eR.'.-_*em^Tn9oTt�r=........,,.,q�.r.. ..-�esr-•_4—._A'JR,... _�,... ,yAr,.- "RT4.. SCANNED - *gym ByP � St. Lucie County MOTOR H.P.3 HP VAR MOTOR H.P. SPA HA J BOX INCL TRANSFORMER INCL TIME CLOCK INCL NA 1 ELECTRICAL HOOKUP PAYUCK 1 1 TERMITE TREATMENT INCL. 1 I OWNERS HEREBY ASSUME AND AGREE TO THE PROVISIONS OF THE CONTRACT FOR POOL CONSTRUCTION, AND APPROVE THESE PLANS WHICH ARE MADE APART OF THAT CONTRACT OWNERS SIGNATURE ADDRESS: 7203 S. INDIAN RIVER DRIVE FT. PIERCE, FL.34982 AGENT SIGNATURE: SONJA CORBETT OOLS by GRE DEV,N RESIDENCE DA & ALLISON A BARRIER OR ALARM IS NOT SUBSTITUTE FOR PARENTAL SUPERVISION. NO CHILD SHOULD BE LEFT UNATTENDED. PARENTS SHOULD KNOW THAT ADULT SUPERVISION IS THE ONLY WAY TO PREVENT AN ACCIDENT. THEY SHOULD MAINTAIN CONSTANT EYE CONTACT WITH THE CHILDREN WHENEVER THEY ARE NEAR, OR COULD GET NEAR ANY BODY OF WATER. UNFORTUNATELY, MOST ACCIDENTS OCCUR WHEN THERE IS A LAPSE IN SUPERVISION EVEN FOR A SMALL TIME. NEVERTHELESS, PARENTS SHOULD BE AWARE THAT ANY BODY OF WATER POSES A RISK, ESPECIALLY FOR CHILDREN UNDER 5 YEARS OF AGE. POOLS BY GREG CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH OR INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM WHEN USED BY THE CUSTOMER, FOR ANY REASON BEYOND ITS CONTROL UNDER ANY CIRCUMSTANCES, FOR ANY REASON WHATSOEVER. THE CUSTOMER ASSUMES ALL RISKS DIRECTLY OR INDIRECTLY RELATED TO MALFUNCTIONING OR FAILURE OF BARRIER OR ALARM. POOLS BY GREG, INC. MAKES NO CLAIM WHATSOEVER TO THE DIFFERENCE OF THESE PRODUCTS RULES FOR POOLS > INSTRUCT SABYSITTERS ABOUT POTENTIAL POOL HAZARDS TO YOUNG CHILDREN AND ABOUT THE USE OF PROTECTIVE DEVICES SUCH AS DOOR ALARMS AND LATCHES EM PHASRE THE NEED FOR CONSTANT SUPERVISION. > DURING SOCIAL GATHERINGS AT OR NEAR A POOL APPOINT A DESIGNATED WATCHER TO PROTECT YOUNG CHILDREN FROM POOL ACCIDENTS. ADULTS MAY TAKE TURNS BEING THE WATCHER OTHERWISE, ADULTS MAY BECOME PREOCCUPIED AND ASSUME SOMEONE ELSE IS WATCHING THE CHILDREN. v IF CHILD IS MISSING, CHECK THE POOL FIRST. SECONDS COUNT IN PREVENTING D DEATH OR DISABILITY. GO TO THE EDGE OF THE POOL AND SCAN THE ENTIRE POOL BOTTOM AND SURFACE, AS WELL AS THE POOL AREA. ti DO NOT ALLOW A YOUNG CHILD ON THE POOL WITHOUT AN ADULT. v DO NOT CONSIDER YOUNG CHILDREN TO BE DROWN -PROOF BECAUSE THEY HAVE HAC ^ SWIMMING LESSONS OR ARE WEARING A LIFE JACKET. I v LEARN CPR, BABYSITTERSAND OTHER CARETAKERS, SUCH AS GRANDPARENTS AND m OTHER SIBLINGS, SHOULD ALSO KNOW CPR v KEEP RESCUE EQUIPMENT BY THE POOL BE SURE TELEPHONE IS POOL SIDE WITH EMERGENCY NUMBERS POSTED NEARBY. REMOVED TOYS FROM IN AND AROUND THE POOL WHEN IT IS NOT IN USE. TOYS CAN p ATTRACT YOUNG CHILDREN TO THE POOL. a NEVER PROP OPEN THE GATE TO A POOL. > NO RUNNING, PUSHING, WRESTLING OR DISTURBANCE IN THE POOL AREA. NO CHEWING GUM PERMITTED IN THE POOL AREA )RED CROSS SAFETY SUGGESTION FOR THE PREVENTION OF CHOKING). > DON'T LET LONG HAIR GET NEAR A POOL OUTLET. THE SUCTION CAN CAUSE HAIR OR BODY ENTRAPMENT AND DROWNING. > HAVE A FIRST AID KITAT POOL SIDE. v NEVER SWIM ALONE. v NO JUMPING OR DIVING IN THE SHALLOW AREA OF THE POOL. > DON'T ALLOW CHILDREN TO PLAY AS THOUGH THE ARE DROWNING, A FALSE ALARM MIGHT DELAY A RESCUE IN THE EVENT OF A REAL EMERGENCY. > WHEN DIVING, ALWAYS ENTER THE WATER WITH YOUR ARMS EKTENDTD FIRMLY OVERHEAD AND KEEP YOUR HANDS TOGETHER TO PROTECT YOUR HEAD. DIVING INTO SHALLOW WATER CAN RESULT IN CERVICAL SPINE INJURIES CAUSING PERMANENT PARALYSIS. NEVER DIVE INTO AN ABOVE GROUND POOL. v AVOID THE USE OF ALCOHOL On OTHER DRUGS AROUND WATER 1:1--+ ' I 'YyT'R. 11 m:;' HARVEY E. KOEHNEN rofessional Engineer PE-32831 7206 Elyse Circle Port St. Lucie, FL 34962-3212 Fax (77-2) 469-3035 wz-02�5 NOTE: REMOVE GRATE a 14• PER FT MIN SLOPE WELL POINT RUG FROM MAN OEAIIUR, aW llE DRAIN a ATTACH AUX. PUMP an UR AP TLE i. ..' LINE WHEN EMPTYING POOL MARE MPa(98E `. [ • ,y_" 6"x6" TILE /Ism / ♦� i GRATE SHALL 4" SLAB � -.. t�■ 1jL. ,IM®Y, —Water Velocity —Max 8ft Sec as BE SECURED IN INTERIOR 2500 FIBER MIX / pet FBC 2010—R4101 6 3 PLACE SO FINISH a>h TYP. WALL —Pool Barrier to Comply with FBC 2010—R4101 THAT TOOLS ARE REQUIRED —Skimmers comply with FBC 2010a p V f?41 0 1.21.1 FOR REMOVAL STEEL—TEX FORM �� f� — Equipment Foundation 3'x7' cone 6" slab min 3 5" thick pour in place OR KRAFT WALL i( TYP. ': TRENCH DRAIN FLOOR tT 13 0 12° O.C.B.W. " NOTE: FOR DEPTHS TREADED Y` GREATER THAN 6' ADD PLUG .'... ' { (1)3 COVE BAR 06" O.C. C _ )j �°�� INC GRAVEL B TO PUMP �. 1 TYP. WALL SECTION & WELL POINT (NO SCALE) DECK I ROW OF WATERLINE 11LE WHEN PROVIDED PRESSURE GAUGES INSTALLED ON FILTER SHALL BE AT 20" MAX CHLORINATOR BELOW THE FILTER PUMP FOR FINAL INSPECTION + ++ wATERUNE + ++ WATERLINE uMPsfWR/MN�R & 4 -0 6'—U++ MAX 6" HICKHE 3 -g LIGHT uaNs —T-1 I SLOPE TER Q3 STEEL 012° 0/C E.W. IT" EA 11" is" o SY011LOPF FLOOR SLOPES Vacuum In H X 1.13 Pressure PSI % 2.31 ME A[.OW m rrya emu ( g) (PSI) mow sRosLOnE o�cR""AaA nL REASONABLY MO Feet Of Head Feet Of Head NOT EXCEED 1 FaaT IN T W COMPLY Mm ARnnE< sa 1 �' �2 C�FANER 1.LNE lYAl1 5_6.3 Vacuum Head + Pressure Head c+'ELO -I = Total Dynamic Head 16'-0" 19'-0" JJ V SWIMOUTS PIPING SCHEMATIC TYPICAL SECTION THRU POOL (NO SCALE) (NO SCALE) CUSTOM MOLDED PRODUCTS INC. HYDRO —STATIC RELIEF CMP 25506-32X VGD DEVICE INSTALLED IN SINGIF CHANNEL OUTLET COMPLIANT 32" CHANNEL DRAIN AREAS THAT EXCEED V PER FRC4101.6.6 WATER TABLE IN SHELL COMPUENT W/107.2.1 OF THE 2010 FLORIDA BUSING CODE TRENCH DRAIN 32" CHANNEL DRAIN AND SUMP _ 2.5.+' 25506-320—OM - 1.5" VENT *THREE 2" SOCKET x 2.5° SPIGOT PORTS "DEBRIS GUARD INCLUDED rO GRAM BED *38.79in' OPEN AREA *IAMPO DSTED FLOW RATES *WHITE PVC BODY MAIN DRAIN *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (Well) when using 2" plumbing. The maximum flow rating far this suction POOL DETAIL fining with the outer parts plugged and the center port open is 200 GPM (floor) and 168 GPM (NO SCALE) (wail) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (nil) when using 2" plumbing. Pipe Size 6 fps 8fps 1' 16 gpm 0.14' 21 gpm 0,23' 1,5' 37 gpm 0.08' 50 gpm 0,14' 2' 62 gpm 0,06' 82 0,10' 2,5' 88 gpm 0.05' 117 gpm 0.0or 2_ 3' 136 gpm 0.04' 181 gpm 0,07' 4' 234 gpm 0,03' 313 gpm 0.05' 6' 534 gpm 0.02' 712 gpm 0,03' OUTSIDE ANGLE OF REPOSE 6' AND FURTHER 14' THICK WALLS EBAR RENAR D.C.E O.C. EACH WAY Determine System Flow Rate: Minimum Flow Rate Required: 35 m per skimmer 3' TO 8' — 6° THICK WALLS W/�3 RF9AR 912" C. EACH WAY - '" Y 9 � 9P 0' TO 3' — 8° THICK WAILS W/#3 REB•R e12' O.C. EACH WAY `� 1. Calculate Pool Volume: _ XXX ___ft__M _x 7.48(gal/Ft) _ XXX _—gal _.� (Turnover Minutes) of Flow Rate) (Feature Flow Rate) (System Flaw Rate) y, (Surface Area) (Average Depth) Volume gallons) 9 it. . A e -- -- — ge p 'n ns 2. Determine Flow Rate: _ XXX gal / XXX _ XXX __+_ XXX ___=___XXX '�"""` ;�;✓P� r �`�'&� - (Volume) i es)s (Po te) (Fe te) (S st s tL Determine Pipe Sizes: Trunk Piping to be_L5 _inch to keep velocity ® 8 fps max. at_117 gpm Maximum System Flow Rate. 3 ft. Return Piping to be�,�_inch to keep velocity It 8 fps max. at 117 -gpm Maximum System Flow Rate. Main Drain Cover(____SEE A80VE------) System Flow Rate must not exceed approved cover flaw rote. �:. ter• (Make and Model) See Engineering Page for Drain Configuration d Q Q � 3 3 F� IXOAYAnON INTO THE ANGLE of REPOSE Is ALLOWABLE PRowDED: Pump Model PENTAIR INTELLIFLO VS-3050 H.P. 3 (,j✓�' ' SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE Total H.P=H.P.xwi icefaW.I H.p.ormoremustbe2speedorvadeblespead SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT Filter Make PENTAIR C&C Size 150 * r {NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES Filter min. area based on 6hr.mmovMflow rate el. COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED P� 9 136D min. = Flow Rate PRIOR TO THE POURING OF THE PATIO DMde G.P.M. by Cartridge=.375orSsnd=ISOr D.E.=2 Time Controller make ON PUMP Model ------ Controls must operates minimum of two speeds POOL PATIO The higher speed orenMeisnot toMond anenormal cycle or24has, whichaverblWes MISC. NOTES WATER LEVEL '.'.r..'•:'t:.•i.::'._: :'::'..: 'r.C. k: 1. ALL STEPS AND SIMMOUT BENCH EDGES WILL HAVE 24 CMnLE BORDER OF OPPOSITE .`A, : . • - COLOR OF GEM FINISH FOR VISIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE •; DECK RAISED +6" ABOVE POOL g ` t.; FROM THESE PLANS AND ALL PROPOSED ONSK 10" MIN O0 'X t. SUPPLY ARE SUBJECT TO,ANY :. coNou"T REQUIRED6YFIELD.INSPECTORSTNA MpY SE NECESSARY IN ORDER TO __ _ - LE CODES: UNDERWATER LIGHT NICHE ' COMPLY WITH ALL, ApPL�CA9 DESIGNED FOR: @rFESSIONALIWGI E. xoP&3Z 3 UGHT u:t— HtOP0SiL2DS ELY$fi CIRCLEP&32831 STEP DETAILS �A�LrS,BYGREG PORT STLUCT8,PL34952 APPROVED r T. TREAD IS MIN OF 10° MCP. NICHEENCASED NGUNITE � GROUND CLAMP DEVf917 RESIDENCE M2)489"3035fax 2. RISER NOT GREATER THAN ARE 12" EXCEPT IF •;'- : `r " A�L`f- Ma RE THAN (3) TRESS ARE USED CONTINUOUS BOND WIRE 7302 S. III M RNER DR. 3. ALL STEPS TO BE SOLID GUNITE 4000 P.S.I. POOL FINISH ''"' COMMON TO POOL STEEL, STEPS RAILS & EQUIPMENT FP PIERCE, FL �f (NO SCALE) UNDERWATER LIGHT DETAIL (NO SCALE) OP/05/44 A u __ . POOL 464 SQ. FT, X 89 LN. FT. nFr_K 418 SQ. FT. EXISTING DECK NA I+^^.. D PER PLAN CHLORINATOR PENTAIR INTELLICHLOR HEATER NA FILTER CARTRIDGE CC150 misc. SUN DECK WITH BUBBLER & 1 L DIVAN RESIDENCE I rC SAvC-P- -P ooL ir0c LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 6 X 6 WATERLINE TILE GP82348B3 SHEET TILE 2 X 6 STEP TILE GP82348B3 OVER POUR YES HAND HOLDS NA GEM FINISH BLACK JEWEL (LIFETIME) BABY BARRIER BLACK DECKING BIRCH GRAY PENTAIR INTELLICHLOR SALT GENERATOR NIc4F X 3(c t)LE-- SI ACINF L , Copes'pRIc_Lz-D cN h— I APPRuPAIATL�Ly �" )n, FRLI-i, a ^^L^lV 1'U 1 UIIL' r� POOL SPECIFICATIONS MAXIMUM WIDTH 19 MAXIMUM LENGTH MINIMUM DEPTH 3•'/,+ MAYIMIIM LICDTY NA K INCL 1—.RETURNS POOL: 4 RETURNS SPA NA —� I ELECTRICAL HOOKUP PAYUCK ' e7 OWNERS HEREBY ASSUME AND AGREE TO THE PROVISIONS OF THE CONTRACT FOR POOL CONSTRUCTION, AND APPROVE THESE PLANS WHICH ARE MADE APART OF THAT CONTRACT OWNERS SIGNATURE ADDRESS: 7203 S. INDIAN RIVER DRIVE FT. PIERCE, FL.34982 AGFTIJT STGNATURE: .S:' NTA C,*)rZ' ;r OOLS by GRE DEVAN RESIDENCE DAN & ALLISON A BARRIER OR ALARM IS NOT A SUBSTITUTE FOR PARENTAL SUPERVISION. NO CHILD SHOULD BE LEFT UNATTENDED. PARENTS SHOULD KNOW THAT ADULT SUPERVISION IS THE ONLY WAY TO PREVENT AN ACCIDENT. THEY SHOULD MAINTAIN CONSTANT EYE CONTACT WITH THE CHILDREN WHENEVER THEY ARE NEAR, OR COULD GET NEAR ANY BODY OF WATER, UNFORTUNATELY, MOST ACCIDENTS OCCUR WHEN THERE IS A LAPSE IN SUPERVISION EVEN FOR A SMALL TIME. NEVERTHELESS, PARENTS SHOULD BE AWARE THAT ANY BODY OF WATER POSES A RISK, ESPECIALLY FOR CHILDREN UNDER 5 YEARS OF AGE. POOLS BY GREG CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH OR INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM WHEN USED BY THE CUSTOMER, FOR ANY REASON BEYOND ITS CONTROL UNDER ANY CIRCUMSTANCES, FOR ANY REASON WHATSOEVER. THE CUSTOMER ASSUMES ALL RISKS DIRECTLY OR INDIRECTLY RELATED TO MALFUNCTIONING OR FAILURE OF BARRIER OR ALARM, POOLS BY GREG, INC. MAKES NO CLAIM WHATSOEVER TO THE DIFFERENCE OF THESE PRODUCTS RULES FOR POOLS ➢ INSTRUCT BABY-SITTERS ABOUT POTENTIAL POOL HAZARDS TO YOUNG CHILDREN AND ABOUT THE USE OF PROTECTIVE DEVICES SUCH AS DOOR ALARMS AND LATCHES, EMPHASIZE THE NEED FOR CONSTANT SUPERVISION. ➢ DURING SOCIAL GATHERINGS AT OR NEAR POOL APPOINT A DESIGNATED WATCHER TO PROTECT YOUNG CHILDREN FROM POOL ACCIDENTS. ADULTS MAY TAKE TURNS BEING THE WATCHER OTHERWISE, ADULTS MAY BECOME PREOCCUPIED AND ASSUME SOMEONE ELSE IS WATCHING THE CHILDREN. ➢ IFA CHILD IS MISSING, CHECK THE POOL FIRST. SECONDS COUNT IN PREVENTING DEATH OR DISABILITY. GO TO THE EDGE OF THE POOL AND SCAN THE ENTIRE POOL BOTTOM AIND SURFACE, AS WELL AS THE POOL AREA. ➢ DO NOT ALLOW A YOUNG CHILD ON THE POOL WITHOUT AN ADULT. ➢ DO NOT CONSIDER YOUNG CHILDREN TO BE DROWN -PROOF BECAUSE THEY HAVE HAD SWIMMING LESSONS OR ARE WEARING A LIFE JACKET. ➢ LEARN CPR, BABYSITTERSAND OTHER CARETAKERS, SUCH AS GRANDPARENTS AND OTHER SIBLINGS, SHOULD ALSO KNOW CPR > KEEP RESCUE EQUIPMENT BY THE POOL BE SURE A TELEPHONE IS POOL SIDE WITH EMERGENCY NUMBERS POSTED NEARBY. ➢ REMOVED TOYS FROM IN AND AROUND THE POOL WHEN IT 15 NOT IN USE. TOYS CAN ATTRACT YOUNG CHILDREN TO THE POOL. ➢ NEVER PROP OPEN THE GATE TO A POOL. ➢ NO RUNNING, PUSHING, WRESTLING OR DISTURBANCE IN THE POOL AREA. NO CHEWING GUM PERMITTED IN THE POOL AREA (RED CROSS SAFETY SUGGESTION FOR THE PREVENTION OF CHOKING). DON'T LET LONG HAIR GET NEAR A POOL OUTLET. THE SUCTION CAN CAUSE HAIR OR BODY ENTRAPMENT AND DROWNING. ➢ HAVE A FIRST AID KITAT POOL SIDE. ➢ NEVER SWIM ALONE. ➢ NO JUMPING OR DIVING IN THE SHALLOW AREA OF THE POOL ➢ DON'T ALLOW CHILDREN TO PLAY AS THOUGH THE ARE DROWNING. A FALSE ALARM MIGHT DELAY A RESCUE IN THE EVENT OF A REAL EMERGENCY. ➢ WHEN DIVING, ALWAYS ENTER THE WATER WITH YOUR ARMS EXTENDTD FIRMLY OVERHEAD AND KEEP YOUR HANDS TOGETHER TO PROTECT YOUR HEAD. DIVING INTO SHALLOW WATER CAN RESULT IN CERVICAL SPINE INJURIES CAUSING PERMANENT PARALYSIS. NEVER DIVE INTO AN ABOVE GROUND POOL. VOID THE USE OF ALCOHOL OR OTHER DRUGS AROUND WATER. SLANNED BY t. Lucie County