May 8, 2014
>
N Pools by Greg
ro 8886 South Federal Highway
Port St. Lucie, Florida 34952 SCANNED
o Re: Pool Backfill Evaluation By
Divan Residence _ _ St. -Lucie counh,
7203 S Indian River Drive
y Ft Pierce, FL
d Permit No.: 1402-0285
Gentlemen:
v
Nutting Engineers of Florida, Inc. has performed geotechnical engineering services
for the referenced project. The area between the house and the proposed pool was
ro probed with a Static Cone Penetrometer to determine the level of compaction of the
° backfill material. Three probes were performed at the following locations:
.Y
r 1) 2' from pool on east side, 15' from house at southeast end.
2) 2' from pool on east side, 15' from house at approx. center.
v3) 2' from pool on east side, 15' from house at northeast end.
? c
It is our opinion that the pool backfill as indicated by the above test locations has
J: r W been compacted to a density of the order of 95 percent modified Proctor.
We appreciate this opportunity to be of service. Should you have any questions,
a please contact our office at your convenience.
Resp Ily Submitted,
° N N NGINEERS F FLORIDA, INC.
5
co ' r lossi, P. # 2603
Project Engineer
ro 1 9
c
m
Pools by Greg —Divan
v
c
L
V
v
0
0
v
tD
0 F F I C E 5
Palm Beach
Miami -Dade
Nutting GeoEngineern Construction Materials
Erigineering, Testing, &Inspection
Environmental Services
Do
Engineers Offices throughout the state of Florida
of Florida Inc.I Established 1967 www.nuttingengineers.com info@nuttingengineers.com
YourProjectis Our Commitment
January 10, 2007
Life Saver Pool Fence Systems, Inc.
1085 Southwest 15th Avenue SCANNED
Delray Beach, FL 33444 BY
Attn: Eric Lupton St. Lucie County
Re: Verification Testing & Inspection
Dear Mr. Lupton:
Life Saver Pool Fence Systems, Inc. retained Nutting Engineers of Florida Inc. to test Life
Saver's D11OX-6 and S117X-6 Product lines to verify there conformity with ASTM Standard F-
2286-05.
The test specimens consisted of fifteen (15) foot sections of representative safety fencing. The
section tested measured forty-eight (48) inches high for the D110X-6 Product and (60) inches
high for the S117X-6 Product. They were installed with horizontal spacing of thirty-six (36)
inches. The representative samples were installed as per the ASTM Standard F-2286-05
Section 4.
We have completed the performance tests for vertical load and impact testing in our facility
based on the noted ASTM Standard as well as reviewing test results from Twitchell
Corporation and TexTest.
Conclusion:
Based on our testing and the information provided to us for review that the products that were
found to meet or exceed all minimum requirements put forth by ASTM F-2286-05
Sincerely
NUTTING ENGINEERS OF FLORIDA, INC.
Dan Hartke Red Javl n, P.E. 60223
Director of Operations Se for Engineer
1310 Neptune Drive • Boynton Beach, Florida 33426 - (561) 736-4900 - Fax (561) 737-9976
Broward (954) 941-8700 • Port St. Lucie (772) 408-1050 • Miami Dade (305) 624-0060
NUTTING
ENGINEERS
OF FLORIDA, INC.
ESTABLISHED 1967
November 8, 2006
M.C.N. Life Saver Pool Fence, Inc.
691 SE Calmoso Drive
Port St. Lucie, Florida 34983
Attn: Nelson Paula
Geotechnical & Construction Materials
Engineering & Testing • Inspection
SCANNED Environmental Services
St. LucieCOOn$y Offices throughout the state of Florida
www.nuttingengineers.com • info@nuttingengineers.com
Re: Verification Testing & Inspection
Proposed Residential Pool Child Protection
9931 Butternut Lane
Port St. Lucie, Florida
Dear Mr. Paula:
M.C.N Life Saver Pool Fence, Inc. retained Nutting Engineers of Florida Inc. to test Life
Saver Safety Pool Fencing for resistance to lateral pressures on Vertical Post Supports.
The test specimens consisted of (48) inch x 1" diameter high removable aluminum pole
sections into 1 1/8" x 4" polypropylene sleeves drilled into concrete paver tiles. The
section tested measured thirty-six (36) inches high from the top of the paved deck and
had a horizontal spacing of thirty-six (36) inches. The representative samples were
installed as per the "Florida Residential Building Code" section R4101.17.1.11 through
R4101.17.1.15 and Florida Statue 515.29 which states: Vertical posts of the child mesh
safety barrier shall extend a minimum of three (3) inches below the deck and be spaced
no greater than thirty-six (36) inches apart.
At the time of testing, a lateral force was applied to a single post at a measurement of
thirty-six (36) from the surface of the deck. The resistance to lateral pressures was
found to exceed 70 Pounds of pressure before failure on any single post in a free
standing installation.
Conclusion: The products tested were found to exceed the required 52lbs. of horizontal
force measured at 36" prescribed by the Florida Building Code section R4101.17.1.15
Paragraph 1.
Attached with this report are photographs of the paver system used at the time of the
installation of the Removable Child Barrier.
615 S.W. BIL B o0wa d ( 54) 941•-8 00 - Palm Beach • PORT ST. h(5 1) 7 6 49008 Miami -Dade de8(3 5) 824-006072) 4011-1049
Should you have any further questions, please feel free to contact this office at anytime.
Sincerely
NUTTING ENGINEERS OF FLORIDA, INC.
(2Z6; (7-- -
Richie Roberts
Division Manager
NUTTING
ENGINEERS
OF FLORIDA. INC
ESTABLISHED 1967
Reza da"vidan,21
P.E. #60223
Director of Engineering