Loading...
HomeMy WebLinkAboutENGINEERING - FOUNDATION - PAD COMPACTIONK Client: A. M. ENGINEERING AND TESTING, INC. 3504 INDUSTRIAL 33RD STREET FORT PIERCE, FLORIDA 34946 LOCALOmm: (772) 461-7508 FAX: (772) 461-8880 REPORT OF'FOUNDAT-ION PAD COMPACTION B & D Grading L Site: Lot34-35, Clubside, 9509-9507 Crooked Stick La. (Four Plex) The Reserve. St. Lucie County, Florida Stripped Surface Report Date: 7/15/03 Project No: Report No:. 544 Permit No: 23060436 Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. Density tests were performed in the upper one foot of natural ground. HCP readings were taken in hand auger- boreholes at one foot intervals to a depth of two feet. The density tests were performed in geneal compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location = Elevation (feet) Dry DenA Percent Compaction In Place Proctor 544 7/15/03 S.E. Comer 0-1 101.9 106.1 96.0 Center 0-1 102.3 106.1 96.4 N.W. Comer 0-1 102.8 106.1 96.9 Ali elevations are below stripped surface. At the time of our testing no information was available regarding the foundation pad setbacks. In the locations that were tested, the upper two feet of natural ground have been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Distribution: Submitted by: a Client — 1 A. M. ENGINEERING AND TESTING, INC. SLC Bldg. Dept. -1 Kolter (Fax) —1 Rebecca Grant Ascoli, P.E. Florida Registration No. 51863 &V,IYTLELOGBOOKWouseJobsIB &D Grading, 1nc1544-Lot 34-35, Clubside(SS).doc A. M. ENGINEERING AND TESTING, INC. 3504INDUSTRIAL 33RD STREET r� - FoRT PIERCE, FLORiDA 34946 d7(,'q/1/ LOCALOFFicE: (772)461-7508 FAx: (772)461-8880 at ��NIIVED REPORT OF FOUNDATION PAD COMPACTION Client: B & D Grading Report Date: 7/15103 Project No: Report No: 545 Site: Lot 36-37, Clubside, 9505-9503 Crooked Stick La. Permit No: 23060436 (Four Plex) The Reserve. St. Lucie County, Florida Stripped Surface Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. Density tests were performed in the upper one foot of natural ground. HCP readings were taken in handauger boreholes at one foot intervals to a depth of two feet. The density tests were performed in general. compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location Elevation (feet) D Densitysf) Percent I Compaction In Placel Proctor 545 7/15/03 S.E.- Comer 0-1 _ 102.5 1 106.1 1 96.6 Center 0-1 103.0 106.1 97.1 N.W. Comer 0-1 103.6 106.1 97.6 * All elevations are below stripped surface. At the time of our testing no information was available regarding the foundation pad setbacks. In ihe.locations that were tested, the upper two feet of natural ground have been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Distribution: Client —1 SLC Bldg. Dept. - 1 Kolter (Fax) —1 1 . \ , Submitted by: A.'A ENGINEERING AND TESTING, INC. Rebecca Grant.Ascoli, P.E. Florida Registration No: 51863 F.'VJ=L0GB00KVIouseJobsD &D Grading, Inc1545-Lo13637, Clubslde(SS).doc