Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED DOCUMENTS
-.� • '- r�' a '� r . SLCCDV Form No.: 001-02 CERTIFICATION: - OWNER INFORMATION: (' NAME: t+ti�S L TZj L P This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of ADDRESS: _ _ R�.SE<RV [�a capacity, if applicable,_ for the permitted work. I certify -that no work or installation- has commenced prior to the issuance of a permit i(obiiuRe� t7j.+�,CQ 5u�-r� 8or— and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, CITY: W8g-17 P/bLfA Seger;} STATE: L ZIP 33'-FD i TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. PHONE (DAYTIME): The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non - BELOW. residential use. FEE SIMPLE TITLEHOLDER: N/A - ' ADDRESS: NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING • TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND. TO OBTAIN CITY: STATE: ZIP FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. PHONE (DAYTIME): ( I NOTICE TO APPLICANT: AS THE APPLICANT.FOR-THIS BUILDING PERMIT, IF IT IS NOT YOUR RIGHT. TITLE AND INTEREST THAT IS SUBJECT TO ATTA -HMENT; AS A CONDITION OF THIS PERMIT YOU CONTRACTOR INFORMATION PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. ST. of FL REGJCERT #: C.$G . �64p l0 ST. LUCIE COUNTY CERT #: (r1loS(D - BUSINESS NAME: KOLZrWR 3 I OWNER'S AFFIDAVIT: [;certify that all the foregoing information•is accurate and that all work will be done in corn !ante QUALIFIERS NAME;._ �aEi�l2'Z' J yi I, with all applicable laws regulating construction and zoning,,--' ADDRESS: D I " .•Y CITY: PDR'C" S-r LIhGIE� STATE: 'FIL ZIP 34gefe : OWNER/CONTRA _ IGNATURE CONTRAC OR. ATURE- - -- (2) `&J3^ 4�03 PHONE (DAYTIME): FAX NO. �� Li L-,►D3 ' - - _ - i. STATE OF FLORIDA STATE OF FLORIDA � COUNTY OF S.-T'- We iE COUNTY OF' 's `Ltac« 4RCHITIENGINEER: �t�,ZZaI li£.bt p�t�C� 1�`��TG � �(�NI�B.L�,S - � - - 4DDREss: 1 �7� �(oRA nt eLU�' SuLTT� 2b3 The foregoing instrument as acknowledged The foregoing instrument as acknowledged befpre me is— a o 20o by� — before methl's' V;ayof� 20d� b NTY: b�I-dcl�l��'- - STATE:' jP( Zip °�Z� V who is person_ all know to me r who V� Is onall known tome he produ as identification. 45nature wh as produced as identification. 'HONE (DAYTIME): ��I loSH 415I � _ -. .. _.. ig ature of Notary gof Notary 3ONDINGCOMPANY: W/� 1 I WDRESS: KV � tG� . _ I I, _ /" t CD 0P.itr Type or Print Name of Notary Type of Print Name of Notary 'm' STATE: Zip Notary Public Title Notary Public Title IORTGAGE LENDER: N/A Commission yumq�(................... Cori;mission Number LYNNE MOORS '• •••••...... ............ ADDRESS: (seal) or ",. C LYNNE MOORS rn�oComm9 ODM328M8 :�K_ Fames B/23rzar� (seal) s.S:B a Cammn DDo232&% 4TY: STATE: LP 'y?orwr' BMW ew(BW)43242Ma� ;o Bon �1Bg 82YtOD7 FlorMg Nora Assn , 1� - '';;?�nc :` dm uuu (8W)432-4254. NOTE TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED N"'..............' MPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. after notification it will be voids and returned to you by mail. BP #: SECTION: R TOWNSHIP: �% RANGE: MAP NO.: / ZONING: // LAND USE: LOT CVG %: TAZ NO.: FLOOD ZONE: FIRM MAP #: - 1ST FLR ELV: MAX HGT: CST TYPE: I / Y OCCP TYPE: ��-'/ I L� MAX. OCCP: # OF FLRS: WATER: SEWER: SPRINKLERS STORMWATE ' R LOT OF REC (befr 1/90). LOT OF REC (aftr 1190) LOT SPLIT LOT SPLIT . REQ'D - - - APPRV'D DECAL LIBRARY , . PARKS' _ >- PERMIT NUMBER IMPACT FEE O• IMPACT FEE �(/i FEE REPORT PUBLIC BLDG HABITABALE RADON FEE CODE /O� IMPACT.FEE // AREA- _ i (RADON) _ Y N ROAD GROSS ROAD CREDIT TOTAL ROAD IMPACT ZONE IMPACT FEE:. DUE' /, q� / IMPACT'FEE'._ - SCHOOL CREDIT _ � '� s€ -- TOTAL - IMPACT FEE 'SCHOOL IMPACT FEE POLICE FEE // FIRE FEE , MISC FEES: TOTAL POLICE/FIRE/ MISC. FEES Y N ADDITIONAL SPECIFY: TOTAL ALL PERMITS FEES . READ _ REVIEWS ZONING• •..... ZONING PLANS = __VEGETATION . -SEA i MANGROVE - • -REVIEWED BY :EXAMINING _ .._„ _ _ TURTLE DATE - ..._.,: . COMPLETE %�� • 6. ..:�Q .lp/ GJ ' 161910 i.... INITIALS 1A,91A. % / V1 DATE FILED: PLAN REVIEW FEE: ALL r36 RECEIPT NO.: PERMIT NUMBER: MUST BE COMPLETE 8t FILLED IN TO BE ACCEPTED SCANNED ST. LUCIE COUNTY PUBLIC WORKS BY BUILDING &ZONING DEPARTMENT - St:LUCIEft* 2300 VIRGINIA AVENUE _ p �Op10Q FORT PIERCE, FL34982-5652' ` 561-462-1553 APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE 8l 3 I - 81 y / PROJECT INFORMATION C r - ps L 1. LOCATION/SITE ADDRESS: S U>G L 3r-t MI.LLLt CAJ`( N d fq)V 3 q`) 9 2. S/D NAME: 't<QX VILILAGM SITE"PLAN NAME: 'c S Lz 3. PROPERTY TAX - ID#: 3�2�'(—<>�^��- �� �i�n�lC0 71 4. LEGAL DESCRIPTION (attach extra sheets If necessary): Sam S+RRVF LN FLAT ? 5 BOOK �� 6 eNO LOT E 7. K�Z. � 6..,I:= O. ]3� 9. PARCEL SIZE: j16RE5 SQ FT !l. 2 3�f LOT DIMENSIONS 1/08 X 445.9 10. DESCRIPTION, OF CONSTRUCTION PROJECTOR WORK ACTIVITY NEu� �L1S�-Rt tGTcard e.. uurr �Ar Fi �y 11. SETBACKS (ACTUAL) FRONT: BACK: RIGHT-' LEFT Ins.93 ]•oo SIDE O SIDE: O 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) , 13. DESCRIPTION OF PROPOSED USE: T�HS\bBNTIPoL 14. Sq. Ft./CONSTRUCTION: l2f 04 15. Sq. Ft. 1st Floor: 16. VALUE OF CONSTRUCTION: $ ��77,O 9 c) O The value of construction Is used to determine the amount of pertnit fees to be assessed. SL Lude County reserves the right to question and/or modify the indicated value of construction if it Is demonstrated that the submitted figures are not ooilslstent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. - ST LUCIE COUNTY ROAD IMPACT FEE CALCULATION FORM DATE: NAME OF FEE PAYER: ADDRESS: PERMIT #: ROAD IMPACT ZONE: 15 03 '7b1:71L�I M4hft Cd. SCANNED ao i o BY St. Luce County m(I1�QCArn �3 THE IMPACT FEE CALCULATED HEREIN HAS BEEN DETERMINED BASED ON THE FEE SCHEDULE ADOPTED, EFFECTIVE 10-01-03. IMPACT FEE CALCULATIONS LAND USE TYPE: (# SQ FT (PER 1000) X FEE ROAD: PUBLIC-BL-DGS• - FIRE EIYI MULTI-FAM(#UNITS) X FEE iW"?- ,�/� ROAD: I7 SCHOOL: LIBRARY: PUBLIC BLDG% P PARKS: POLICE: FIRE/EMS: _ ✓-moo �G s�, (0 78 = I BBB ✓ 3qo m eserve Community Development District St. Lucie County Building Department 2300 Virginia Ave. Ft. Pierce, FL 34982 Reference: Multi -Family Construction To Whom It May Concern: SCBcre�N,® Ql_D� t 3C3L Address: M u,L_Lt ratty GRc ra Concerning the above referenced project, this letter will serve to notify all interested parties that water & sewer service has been reserved & will be provided upon request by the Builder. Payment for reservation charges, hook-up fees, and any necessary metering equipment is required at time of service. Since r o sapo, airman serve D elopment District 2140 N.W. Reserve Park Trace + Port St. Lucie, FL 34986 + Telephone: (772) 468-4604 + (772) 467-157 W Job Address �vlt,l� �.vlvlrl�IJtilr l,� "I v LION Rr . �IDENTIAL PLAN IZ.'JIEW FORM SCANNED BY ATTACHMENTS Sealed Drawings -Name, etc. FBC 104.2 Lot Survey FBC 104.2 Manual "r' Room by Room Cal FL Energy Code Product review or affidavit FBC 1606.2.2.1 FOUNDATION Lude GE)Permit # 6 O Wind Borne Debris Protection FBC 1606.1.4 Wind Load Design ,Survey Matches Structural Plans )Zhergy Evaluation Design wind pressures for openings I FBC 104.22 FBC 104.2 FL Energy Code FBC 1606 / 1707A Footing Details FBC 1804.1 to 'or Bearing Walls (detail) FBC 1804 Change in Elevations FBC 1804 j lumn Pads FBC 1804 Area Tabulation FBC 104.2 Dimensions FBC 104.2 1111 %j%,a V1%tu. Wall Section -CBS FBC 104.2 /2101 Wall Section FBC FBC 104.2 / 2308 Interior Bearing Walls FBC 104.2 / 2308 Frame to Block Details FBC 104.2 / 2309.5 Bay Window Detail FBC 104.2 / 2308 in ow Seat Detail FBC 104 / 2308 Gable End Detail FBC 104.2 CH-16 F nt Entry Details - Ext. Ceilings FBC 104.2 / 2308 Porches - Exterior Ceilings FBC 104.2 CH 16 Knee Walls FBC 104.2 / 2308 Butt Glass Detail FBC 104.2 /2405 Bearing Wall Header g FBC 104.2 / 2308.3 Fire Place / Chimney Detail FBC 104.2 CH 28 Mindow / Door Buck Details FBC l04.2 / 1606 Tie Beam Change in Heights FBC 104.2 / ACI Team Block -Poured Tie Beam FBC Ch 1,16,21 Lintel Detail FBC Ch 1.16,21 Glazs Block Detail FBC l04.2 / 2112 •71-+�.Y 1 V1V LiL I Truss Plan FBC Ch-I/ 16 russ Connector Chart FBC Ch-I/ 16 Sheathing Sizes & Nailing Detail FBC Ch-23 / APA nventional Framing FBC Ch-23 Electrical Plan uci� �,.r,.tio-..kwa, Pev<teo alill kdaortn FBC l04.2 / NEC ectrical Calculations, Riser, etc. FBC 104.2 /NEC AC Duct Plan FB11 C 104.2/ FMC ake-Model &BTU's being used FL Energy Code Plumbing Riser FPC 104.2 Balance Return Air FMC Ch-6 INTERIOR Egress Windows FBC 105.4 V ront Door Size (36" x 6'8") FBC T-1004 Bath & Bedroom Door FBC T-1004 oke Detectors FBC / NFPA 72 Attic Access (22"x 36" min.) FBC 2309.6 S tr & Handrail / Guardrail Detail FBC Ch-1 / 1007 Dryer Vent Exhaust FMC 501.3 /509.3 Exhaust Fan Venting FMC 510.3 / 506.1 1st Review Date 1Q/44 / 2nd Review Date _/ /_ Final R iew /� Plans Examiner Name lA%i %�in/i7 �/� /r lnp�(/ Signature � 142 iyy' 744 I 2,_0 ——/— 7L 10 —/-05 2 ------ 42--1 — 3 tF 2-- SCANYNED B S-- Lucie County t. un --tel- _J2 A —.k 1'2- 5 - 0 ?o 0 - 30,3 - 13 �6 ST. LUCIE COUNTY BUILDING &ZONING �- 2300 VIRGINIA AVENUE SCANNED OI;10P FORT PIERCE. FL 56146216M 82-5652 e County FILLED LANDS AFFIDAVIT fit. Luc I, the undersigned, am the owner of the following described property: S'62-'7— OOD - cOao - oeo13 SLID US9 Mu for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number . I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge Ahat in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. �OB&RT J Property Owner Name Property Owner Signature Date STATE OF FLORIDA. COUNTY OF S7— ACKNIDY LEDGED BEFORE ME THIS �9� DAY OF ..20 0 BY ILlll.�t/1/C. 1sY� � Q HOISPERSONALLY KNOWN TOM RWHOHASPRODUCED AS IDENTIFICATION. LYAleje, kAPO/L(s GN RE OF NOTARY TYPE OR PRINT NAME OF NOTARY (SEAL) NOTARYPUBLIC TITLE COMMISSION NUMBER innunnunn........nu.wnn.. ....LYNNE MOORE CommA DD0232M " = z Y+`= Expim 9232WY yf :e Banded MN (800)432-42542 5.....................................Fla1tle NotaW .....� d-26-2000 S.18AM FROM e- I ST. LUCIE COUN-rY PUBLIC WORKS BUILDING & ZONING DEPAR I NIENT BUILDING PERMIT SUR-CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number (If appicwa): RB. i�ooyI 1G C-&cVrMRS name) SCANNED By 1 eo g Si. Lucie County CCC058246 has agreed to be the G?aoiz tsub-contractor for Ke-,L_-r1_zy>, " (type of ounsuvction trade) $LDS 139 (name of the pnmo comradvp for the project located at M(uLte,4N CtRe_-t_F It is understood that, (street address or property tax ID !) if there is any change of status regarding our participation with the above men •ioned project, 1 will immediately advise the Building and Zoning Department of St. Lucie I'ounty n by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00)- ESS ousiness name: address: dty.state.zip: phone: (origin.' signatures required): LEVINE Print name Reliable goof✓y GutteY&.Inc 1832-Wabanso Dr Ste#5 Wpst Palm I3nrh. F1 93404 SfiT-ht34sfi 3? c`1-2- -03 Date OFFICE USE ONLY: sLCCC•V WRM N:: 037-00 PFliMii! 15SUE DATE . . 06/19/2003 00:51 772-4& -`7i05 KOLTER HOMES PAGE 02 rHur- Uzi Ut ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB-CQNTRACTOR•AGREEMENT SCANNED BY St. Lucie County St. Lucie County Contractor Certification Number. State of Flodda Certification Number -pi ■Wioamey CAco 4IIQ has agreed to be the H.q.ArC sub -contractor for V6L-MK G' -12-5_ f pe of conatnw= trade) (name at the prim eonaaotorl i3LDG • 13°i for the project located at MuLU6AN It is understood that, (street address or property tax ID Ay if there is any change of status regarding our participation with the above mentioned Project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO.Oda-00). )FFICE'USWONLY' SLOGOV FORM No.: 002-0 PERMrr 0 IBBUE CATS 09/17/2003 04:21 772-4F9-Q505 KOLTER HOMES ,,. PAGE 02 ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lurie County Contractor Certification Number. SCANNED BY 54. Lucie County Vf76T -q-+Gia of Florida Certification Number (If applicable): FLUNeLBIA-le.- y I b-�r_ has agreed to be (companyfindividuai name) the t'LUNt63I sub -contractor for i46wll-s (type of co ltruction trade) �� (39 (name of the prime contractor) for the project located at MGtt lLtr-" CtRcLV_; It is understood that, (street address or property tax ID 0) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO.00"0). BtJSINE QUA FIER( gi I signatures required): signature Print name Date business name: Atil@kl l�r-il i�tt�nb3t lrJ� address: _1. C?. `z)Vq latL:rMoR Sf city,state,zip: Pon 3T LL.(c.tTx- f;z- '6 9�} phone: 3r; ( • 578 M=CL4+ )FF.ICEL1SMMNL'Y; SLrcov FORM NO.: 00, PEtiMfrr< ISSUE DATE 00 11o/Lel lyb3 Uo: F7d //`1-4btl-'lbb� .25L (Z0a1 11M-71-14664M KUL I tH HUP*--b HAUL U FAGS n'L ST. LUC» CotMTY PTJBUC WORKS BunmiNG & .;p0mG DEPARTMENT BUILDING PERWr gja.CONMACTORAGREEMOM SCANNED BY St. Lucie County aL Lucia Count Nurfmr =W d Fbddm Cwdmticn Num6w (H b10): j3 G os 1 �41 n c. PLm;tTk= . Cat�zt}.P� has agreed to be t��ymPetwAwl twln.) the ELF--Z'R1G4L — aub4ontmolortor KbL-*yv� 5 nry of mftrumm e ) $tlrm 051 !rAm N u. pm tPe nCwn for the prcgeot toaatad at Maitre At-t4 Ct'MmLA It is understood that. aninmenerpPnnp mt=M#) H there Is arty change of status mpard(ng DUr participation wRh tNm above mentianad project, I wlll immedlme)y advise the Building and Zoning Oapartmert of St Luds County by personally filing a Change of Contractor Forth (SLC=V FORM NO.004-00). BUSINESS QUALIFIER ronrbalamtao- - owPlP�dy _i Lam. �,- .. hlwlT 0 r tsz pAT¢ IE St. Lucie County ti Frye Gyp Building & Zoning Fo:o BUILDING PERMIT SCANNED SUB -CONTRACTOR SUMMARY BY tucle County will be using the following sub -contractors for the (Company/Individual Name) project located at 13L.1>65. 191 MIALLIC.,XM CtRCt� (Street address or Property Tax ID #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor St. Lucie County/ State of Florida License Number Electrical EAZZ?�V Kbu �t del . ��� 1(o8ia5 Plumbing j �IYIE�RI - l ticl! �LI�M81T.1� I q Z�� p _ oD66 �5�1 HVAC/ Mechanical CoMFeRT Got�ITRoL BZg� Roofing RtiLIP.Bi_� (�vo�lea6 Gu�tRg ��85� ccc o Z9 5 S `i "Gas )FFICE USE ONLY: PERMIT ISSUE DATE: NUMBER: JOANNE HOLMAN, CLERK OF THE CIF T COURT - SAINT LUCIE COUNTY File Number: 2280998 OR BOOK loi PAGE 1035 Recorded:10/01/03 '15:21 SCANNED! NOTICE OF COMAUNBY CE VIENT S>~. Woke County Permit No. Z-6D6l (660 - Tax ID No. a32'7_3 State of Florida County of St. Lucie THE UNDERSIGNED hereby gives notice that -improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided -in this Notice of Commencement. Description of property and street address, Owner Reserve Homes LTD.. LP. Address 9700 Reserve Blvd., Port St. Lucie. Owner's interest in site of improvement 100( Fee Simple Title holder (if other that owner) Address t""1�1D 141 (LkZ 148 1q4:: R">i ag E Contractor Kolter Signature Homes Inc Phone 772-468-4703 Address 2160 NW Reserve Park Trace Port St Lucie FL 34986 -Fax 772-468-4603 Surety N/A Phone Amount Lender Persons within the State of Florida designated by Owner upon whom notices or other document's may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: Name - ? Phone Address Fax In addition to himself, owner designates of (Phone Fax ) to receive a copy of the Lienor's Notice as provided id Section 713.13 (1) (b), Florida Statutes. Expiration date of notice of commencement is one year from the date of recor ' g ss a different date is specified. O NATURE . STATE OF FLORIDA, COUNTY OF ST. LUCIE Sworn to nd subscLbbed before�ne this day of fir, — 2003 tdy zn • Vaa C who is ersonall Miown tom r who has produced STATE OFFLORIDAes identification. ST. LUCIE COUNTY S A OF NOTARY THIS TO CERTIFY THAT THIS IS A glGiUA!T), (seal) LYN►�1tt htck�/L� TRUE AIuJ CORRECT COPY OF THE TYPE OR PRINT NAME OF UIiG!PJAL. rr` t"". o NOTARY 9nnwom.in NE MO .wumm�nq L'fNNE MOORE JuAP!!E C Et¢mflDD0232a5a p M W3R007 W Bonded u (800�32-0254: l F orlda Nom......... otary Assn., Inc Doputy�Cierj` C00RTi' ...�...i DATE ! A. A ENGINEERING A: -_ TESTING, o ED 3504 INDUSTRIAL 33RO STREET �11 FT. PIERCE, FLORIDA 3494 -' F9 LOCAL OFFICE: (772) 461-7508 REPORT OF FOUNDATION PAD COMPAC ;IQLio �ou�tu bile w s SCANNED Client: Dickerson of Florida, Inc. Report Date: 1219/03, BY 9I3 / y/ /�� �y 4 � Project No: St.L(I; i;0U11ty (�(/1 Report No: 108 ^^\\ Site: Unit 139-144 Castle Pines Permit No: QSC) 9 /(a (O(J Pod 20C, The Reserve, St. Lucie County Foundation Pad Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. Density tests were performed in the upper one foot of fill. HCP readings were taken in hand auger boreholes at one foot intervals from slab grade through the depth of fill. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location Elevation (feet) Dr Density(cf) Percent Compaction In Placel Proctor 108 1212/03 SW Corner 0-1 110.8 113.9 97.3 SE Corner 0-1 111.2 113.9 97.6 Center 0-1 111.0 113.9 97.5 NW Corner 0-1 112.4 113.9 98.7 NE Comer 0-1 111.7 113.9 98.1 * All elevations are below slab grade. The depth of the fill was approximately two feet. The fill should extend at least five feet beyond the building perimeter. At the time -of our testing no information was available regarding the foundation pad setbacks. In the locations and depths that were tested, the fill has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Distribution; ' , Submitted by: Cliehi - 1. ,. A. M. ENGINEERING AND TESTING, INC. Kolier'-Homes — 2 Attn: Shane, Signed & Sealed Rebecca Grant Ascoli, P.E. Florida Registration No. 51863 F:W M DATA\Dickerson of Florida, lnc\Castle PinesV08-11nit 139-144.doc, SL .9 gal e insi lation a MASCO Company s t��y�¢� CERTIFICATION OF INSULATION R-4.1 INSULATION INSTALLED ON EXTERIOR WALLS R-30 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot 144 Block Sub -Division Castle Pines PERMIT #: 23091660 SLC JOB ADDRESS: 8141 Mulligan Circle BUILDER: Kolter Signature Homes, Inc.. GALE W/O: 79089 ATTESTED BY: :DATE:. 3601-A CROSSROADS PARKWAY • FT. PIERCE, FL34945 FT. PIERCE (772) 465-9191 • VERO BEACH (772) 589-1514 • STUART (772) 283.3151 • FAX (772) 489-6758 ale 9n a MASCO Company 0('8yE® St. Lucie Coup IY CERTIFICATION OF INSULATION R-4_1 INSULATION INSTALLED ON EXTERIOR WALLS R-30 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot 143 Block Sub -Division Castle Pines PERMIT #: 23091660 SLC JOB ADDRESS: 8139 Mulligan Circle BUILDER: Kolter Signature Homes, Inc.. GALE W/O: 79087 ATTESTED BY: DATE: 3601-A CROSSROADS PARKWAY FT. PIERCE, FL34945 FT. PIERCE (772) 465-9191 • VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758 insulation a MASCO Company 8C4 IV �CDUn0, CERTIFICATION OF INSULATION R-4.1 INSULATION INSTALLED ON EXTERIOR WALLS R-30 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot 142 Block Sub -Division Castle Pines PERMIT #: 23091660 SLC JOB ADDRESS: 8137 Mulligan Circle BUILDER: Kolter Signature Homes, Inc.. GALE W/O: 79084 IATTESTED BY: 3601-A CROSSROADS PARKWAY • FT. PIERCE, FL 34945 FT. PIERCE (772) 465-9191 • VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758 gale - a MASCO Company CERTIFICATION OF INSULATION &641v t sdi.�u6g ou R-4_1 INSULATION INSTALLED ON EXTERIOR WALLS R-30 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot 141 Block Sub -Division Castle Pines PERMIT #: 23091660 SLC JOB ADDRESS: 8135 Mulligan Circle BUILDER: Kolter Signature Homes, Inc.. GALE W/O: 79081 ATTESTED BY: 3601-A CROSSROADS PARKWAY • FT. PIERCE, FL 34945 FT. PIERCE (772) 465-9191 • VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758 r gale - a MASCO Company SCANNED SY St Lucie cotYF l y CERTIFICATION OF INSULATION R-4.1 INSULATION INSTALLED ON EXTERIOR WALLS R-30 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot 140 Block Sub -Division Castle Pines PERMIT #: 23091660 SLC JOB ADDRESS: 8133 Mulligan Circle BUILDER: Kolter Signature Homes, Inc.. GALE W/O: 79077 ATTESTED BY: 42 DATE: -17 /a ID q i- is �, a • _ •.A 3601-A CROSSROADS PARKWAY • FT. PIERCE, FL 34945 FT. PIERCE (772) 465-9191 • VERO BEACH_(772);589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758 gale- - �nsulat�on a MASCO Company JUL 2 0 2004 S(. Lucie(y Public Works CERTIFICATION OF INSULATION R-4.1 INSULATION INSTALLED ON EXTERIOR WALLS Coon` / R-30 INSULATION INSTALLED IN CEILING AREAS LEGAL: Lot 139 Block Sub -Division Castle Pines PERMIT #: 23091660 SLC JOB ADDRESS: 8131 Mulligan Circle BUILDER: Kolter Signature Homes, Inc.. GALE W/O: 79076 ATTESTED BY: Le DATE: -7 ! l to L/ 3601-A CROSSROADS PARKWAY • FT. PIERCE, FL 34945 FT. PIERCE (772) 465-9191 • VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758 J Soil Treat Property Treated A0 %'PCX(\Ci City PI Lot# M Block Subdivision (�p}S��e �ineC Technician iM� Date Treated —Time Fax) Product Used vvPo.� % of Concentration .�^ SCANNED 8f. LuC a cour L environmental services Ii # of Gallons Used m �S'`kS� 1- 8 0 0- 2 8 5- 7 3 7 8 de One Under Slab Slab Abutments Perimeter Treatment Pest Control Comments: • Lawn Spraying • Termite Control TERMITE"PROOFED Pest Cont o' lls --Finest TERMITE PRETREATING �3q9/6�o DILIEE GENT-cM Environmental Services Mqy g 2004 Notice of Preventative Treatment for Ter (as required by Florida Building Code (FBC) 104.2.6) St. Lucie Coun� 1-866-PRE-TREAT State License - 94495'(/ Pro' ct General Contractor q ED Service Date S- tuc Time Builder �''ip. 6 ounty Lot Block Section Shell Subcontractor i© (:A rv-,c—% Development Name Treatment Type W Structure Address Floating ❑ Monolithic ❑ Patio City 1 Cnty Sc Garage ❑ Driveway ❑ Stem Wall ❑ Owner (�(�[ Addition ❑ Cutouts ❑ Notes 1 I 1 Treatment/Product Detail Type Treatment: Initial Under slab jk Retreat ❑ Final ❑ Product: Dursban TCP_Chlorpyrifos ❑ Concentration: CS, % Square Footage 5i Dragnet ❑ Demon TC ❑ Other Gallons Applied: Linear Footage Asper 104.2.6 FBC - )f soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: This building has been treated in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. Further, the treatment complies with the Florida Building Code. If this flee is for the final exterior treatment, initial and date this line.- �A gq Applicator (print) •;�B ;.• o R •., S� 3100 Northwest Boca Raton Boulevard Suite 106 • Boca Raton, FL 33431 •561-394-411 ,,j b ee 166-P1�L"1 ,ij�AT • FAX 561- 394-3760 �® NMB �.� TERMITE PRETREATING \ DILIGENT 36F166 Environmental Services 2004 Notice of Preventative Treatment for Terr. (as required by Florida Building Code (FBC) 104.2.6) 1-866-PRE-TREAT State License JB94495 Project General Contractor. B Service Date ASt. Lucie county Time Builder Lot Block Section Shell Subcontractor PM 7 I=i ^N � Development Structure Treatment Type rV�S Floating ❑ Monolithic ❑ Patio)o City J Cnty l �— Garage ❑ Driveway ❑ Stem Wall ❑ Owner pp Addition ❑ Cutouts ❑ Nntea 1 Treatment/Product Detail Type Treatment: Initial Under slab Retreat ❑ Final ❑ Product: Dursban TCA- Chlorpyrifos ❑ Dragnet ❑ Demon TC ❑ Other Concentration: S % Gallons Applied: is Square Footage 4 So Linear A per 104.2.6 FBC -If soil chemical barrier method for termite prevention is used final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: This building has been treated in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. Further, the treatment complies with the Florida Building Code. If is notice is for the final exterior treatment, initial and date this line. f\ ( Applicator (print) 3100 Northwest Boca Raton Boulevard Suite 106 • Boca Raton, FL 33431 Rm ?o e • FAX 561- 394-3760 �.' TERMITE PRETREATING , 3 rr/6 DILIGENT ILIGENT Environmental Services Notice of Preventative Treatment for Termit �° (as required by Florida Building Code (FBC) 104.2.6) 1-866-PRE-TREAT State License JB94495 e n �1 JLL.S 2004 St. Lucie �blic Works Project General Contractor SCAN Service Date NcD aZ Time Builder 1r '• Lucie Lot Block Section Shell Subcontractor �fB � � cotmty Treatment Type Development Structure Address / �Floating ❑ Monolithic ❑ Patio 9 I S� ( City Cnty J` Garage ❑ Driveway ❑ Stem Wall ❑ Addition ❑ Cutouts ❑ Treatment/Product Detail Type Treatment: Initial Under slab Retreat ❑ Final ❑ Product: Dursban TC �f_ Chlorpyrifos ❑ Dragnet ❑ Demon TC ❑ Other Concentration: I 5 % Gallons Applied: 2 s Square Footage%w Linear As per 104.2.6 FHC -If soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: This building has been treated in accordance with the roles and laws established by the Florida Department of Agriculture and Consumer Services. Further, the treatment complies with the Florida Building Code. If thi otice is for the final exterior treatment, initial and date this line. Applicator (print) 3100 Northwest Boca Raton Boulevard Suite 106 • Boca Raton, FL 33431 -51 *c z�'k oq • FAX 561- 394-3760 _ TERMITE PRETREATIN -230�16-60 DILIGENT4104.2.6N) Environmental Services orks Notice of Preventative Treatment(as required by Florida Building Code (FB— 1-866-PRE-TREAT State License JB94495 Project General Contractor Service Date—�'�Time Builder RICO 5, CAS[VIED Lot Block Section Shell Subcontractor 1 FD �� SCi� ,nun Treatment Type Development Name Structure Address Floating ❑ Monolithic ❑ Patio City Y 'Y— Cnty S Garage ❑ Driveway ❑ Stem Wall ❑ Addition ❑ Cutouts ❑ a Treatment/Product Detail Type Treatment: Initial Under slatO Retreat ❑ Final ❑ Product: Dursban TC Chlorpyrifos ❑ Dragnet ❑ Demon TC ❑ Other Concentrationsc !! 11 % Gallons Applied: L S Square Footage I Linear Footage _ As per 104.2.6 FBC - If soil chemical barrier method for termite prevention is used, final exterior vea• —r mull be completed prior to final building approval. Certificate of Compliance: This building haq b-a seated in accordance with the rules and laws established by the Florida Department of Agriculture and ConsmAdir Services. Further, the treatment complies with the Florida Building Code. If thi y tice its for th final exterior treatment, initial and date this line. 1 •• (p a J rv�5 •.•••oNµ •• Sr Z ( —0C( Applicator (print) ;',�Q,.• o e . ;S� •; 3100 Northwest Boca Raton Boulevard Suite 106 • Boca Raton, FL 33431 •561-394-411• FAX 561- 394-3760 Ac 1;`II• �,�p� o����� •�• N®M TERMITE PRETREATING Z 36 �1� 0 *EnvironmentalGENT kA2 004 Services Notice of Preventative Treatment for Termit §t• Lucie cow ll� ks (as required by Florida Building Code (FBC) 104.2.6) 1-866-PRE-TREAT State License JB94495 ,A Project General Contractor Service Date ime Builder Lot Block Section Shell Subcontractor i Cif' rV/G Treatment Type SCANNED BY Development to Structure Address Floating ❑ Monolithic ❑ Patio City 1" C Cmy C Garage ❑ Driveway ❑ Stem Wall ❑ Addition ❑ Cutouts ❑ -t(142- Treatment/Product Detail Type Treatment: Initial Under slab &( Retreat Cl Final ❑ Product: Dursban TIC few Chlorpyrifos ❑ Dragnet ❑ Demon TIC ❑r Other Concentration: `S- °/n Gallons Applied: Gs Square Footage Linear Footage Asper Ie4.2.6 FBC - If soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: This building has been treated in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. Further; the treatment complies with the Florida Building Code. If s notice is for the final exterior treatment, initial and date this line: n !firs ,.••oNM•:�` Applicator (print) ;•J��,.•� o 04•• Sit•; 3100 Northwest Boca Raton Boulevard Suite 106 • Boca Raton, Fl, 33431 • 561-3944113 **)ree 866-PI�4`P AT • FAX 561- 394-3760 �C .! •'' --� :. �—� taws ,230T1W TERMITE PRETREATING DILIGENT Environmental Services Notice of Preventative Treatment for Te (as required by Florida Building Code (FBC) 104.2, 1-866-PRE-TREAT State Project General Contractor Service Date S- L Time Builder Lot Block Section Shell Subcontractor Rio VnC4 n^C Treatment Type SCANNED BY GL- t- de County Development Name l��ii �Q. e PvS Floating ❑ Monolithic ❑ Patio 9 City F J(- Cnty S C' Garage ❑ Driveway ❑ Stem Wall ❑ Addition ❑ Cutouts ❑ Notes r�6 Treatment/Product Detail Type Treatment: Initial Under slab Retreat ❑ Final Cl Product: Dursban TC A Chlorpyrifos ❑ Dragnet ❑ Demon TC ❑ Other Concentration: 1 5 % Gallons Applied: t Square Footage ISV Linear Asper 104.2.6 FBC - If soil chemical barrier method for termite prevention is used final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: This building has been treated in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. Further, the treatment complies with the Florida Building Code. If t1gice is for the final exterior treatment, initial and date this line. Yam, 1X61r /b ES ••�NMEMI,'' ...,,,• Applicator (print) ;'J��;, • r o it ,;S'F:•; 3100 Northwest Boca Raton Boulevard Suite 106 • Boca Raton, Fl, 33431 • 561-394-4113 op.lree 166-PI T t AT 0 FAX 561- 394-3760 r,) 37 M c�NCR= 7 30' TONBACK 5 TO E51 PLACED OVER 1PACTED CLEAN FILL 5% PR CTOR DENSITT WITH VAPOR 101E ER SLAB FOR I BrscI M PLACM4 4 7R BAO RJER FLO.Or To 1ELEVATION VIFh VE TOP F RO . E01L BEARING r FOR IS 971a1CTURE .00 P F. MMIMLM / R ELEVATION TO BE IB' MINIMl1M1 I I I I N I n I III SCASN�NED St. Lucie County I I I I I _ I I MEN r GLE ASSOCIATES, INC. Architects • Engineers • Environmental Consultants February 11, 2004 TO: St. Lucie County Building Department Attention: Building Inspector RE: Kolter Homes PGA Village C Model Townhomes Permit # — 30191(p%o Dear Building Inspector: FEB 1 1 2004 St Lucie c ....',A olic Works SCANNF-® BY St. Lucie County Delete the three dowels noted on the attached drawing. This is a 2x4 wall under the landing. This applies to all C model townhomes under construction. If you have any questions or concerns please feel free to call us. Respec yours, Asso iates, Inc. R. QuinriTurner, AIA,NCARB Architect0011,44t Director of Orlando Operations Attachment a 1320 N. Semoran Boulevard • Suite 203 • Orlando, FL 32807 • 407/658-4151 • Fax: 407/658-4410 Architect AA 0002369 • Engineer EB 0005483 • Asbestos ZA 0000034 • Geology GB 0000297 REQUEST FOR 30 DAY TEMPORARY POWER RELEASE DATES - /6 -0.4 PERUrr NUMBER: public PROPERTY AooREsa: j31��133 I35SsI 136116W( +w Lucie County Comm. Devel. Dept Code Compliance Division 2300 Virginia Avenue Fort Pierce, FL 34982-5662 Ph. (581) 462- 2165 Fax (561) 482-1735 a� 139 OUMIVINW BY c §1. bde County THE UNDERSIGNED HEREBY REQUEST RELEASE- OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOTTO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARA- TION FOR FINAL INSPECTION. IN CONSIDERATION.OF APPROVAL OF THIS REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS; I. This temporary power release Is requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree W abide by all terms and conditions of this agreement, Including Building Division Policy, which Is Incorporated herein by reference. 3. All conditions and requirements listed In the attached document entitled "Requirements for 30 Day Power for Tenting' have been fulfilled and the pramises is ready for compliance Inspection. We hereby release arfd agree to hold harmless, St. Lucie County, and their employees from all liabilities and claims of any type or nature which may arise now or In the future Out of this transaction, Including any damages which may be Incurred due to the disconnection of electrical power in the event of violation of this agreement r'- St Lucie County Inspectio���o� 2300 Virginia Avenue Ft Pierce, FL 34982 DEC Q (722) 462-2172 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT ;- 307190 PERMIT # Bldg#139 JOB ADDRESS 8131-8141 Mulligan Cir, Port Saint Lucie, FL BUILDER 80AN'E ue, ., ,s PEST CONTROL CONTRACTOR Hulett Environmental Services BY _ r� r. vVuilly PEST CONTROL LICENSE # JF0001886 I We, the undersigned, hereby certify that we have pretreated the above -described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet of area treated: 8958 Percentage of solution: _ Date of treatment: 02/04/04 ❑ Footing ❑ 1st Treatment ❑ Re -treat ® Slab ® 1 st Treatment r-1 Re -treat ❑ Driveway ❑ 1st Treatment ❑ Re -treat ❑ Pools ❑ 1 st Treatment ❑ Re -treat ❑ Other ❑ 1 st Treatment ❑ Re -treat Chemicals used: Chlorpyrifos Total gallons used: Time of treatment: AM FBC104.2.6 Certificate of Protective Treatment forprevention of termites. A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the poermit is iisued to and another copy for the building permit files. The Treatment Cer�rzcate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number ofgallons used, to establish a verifiable record ofprotective treatment. Ifthe soil chemical barrier method for termiteprevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. N Perimeter. for Final Inspection Sig ature of exterminator NOTE: There tnust be a cou:pleted form for each required treatment or re-treatnent and this form must be on the job site to be picked up by the inspector at tittle of each inspection or the scheduled inspection will fail and a re -inspection fee charged. '`',` 77 r . ,t�"`'. �-fie,:-, Certificate of Occupancy SCANNED BY St. Lucie County This Certificate is issued pursuant to the requirements of the Standard Building Code certifying that at the time of issuance this structure was in compliance with the various Ordinances of St. Lucie County, regulating building construction or use for the following: Certificate of Occupancy No. 23091660-001 Building Permit No. 23091660 Lot: 139 Block: Parcel/Folio Number: Occupancy: Multi —Family Residential Building Address: 8131— 8141 Mulligan Circle Port Saint Lucie, FL 34951 Legal Description: Permit Job Description: Multi — Family Residence / 6 Units Contractofr Kolter Signature Homes Inc. DENNIS M GRIM, CB® BUILDING OFFICIAL Building Official NOTE: 12-15-2004 Date Issued This Certificate of Occupancy is issued to the above named, for building at the above named location only upon the express provision that the applicant will abide by and comply with all the conditions of the Zoning Ordinances and all Ordinances or Building Codes of Saint Lucie County pertaining to the erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and/or equipment, and the plumbing work have been inspected and approved. The issuance of this Certificate grants permission to occupy and use the property described herein only for the use indicated. Any change in use will require a new Certificate of Occupancy. POST IN A CONSPICUOUS PLACE Eastern Metal Supply,Inc SCANNED ACCEPTANC) q+U�. q� 9I9 I0 APPROVED 06/07/2ool EIS 06/07/2004 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed anc original submitted documents, including test -supporting data (8) years. engineering documents, are no older than e 2. . Any and all approved products shall be permanently labeled with the manufactur following'statemeer's name, city, state, and Specific, conditions "Miami-DadeCoControl Approved", or as specifically stated in conditions of this Acceptance. -3. Renewals of Acceptance will not be considered if: a: There has been a change in the South Florida Building Code affecti and the prodri6f is not in ng the evaluation of this'prod compliance with the code changes. b. The product is no longer the -same product (identical) as the one. originally approved. c.-- ...If.:the Acccptance holder.has not oom 1i�d.'With all A. the requirem. acceptance ents of this,. including • - . .... :correct installation of the product.....- : ,.. d-•• The . engineer, who originally prepared signed and sealed the required documentation iriitia submitted is no longer practicing the engineering profession- 4. Any revision a change in the materials, use, and/or manufacture of the product or process shall automatics be cause for termination of this Acceptance, unless written approval has been requested (through t filing of a revision application with appropriate fee} and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any oth purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade. County, Florida, and followed by tl expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance displayed, then it shall be, done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall t provided to the user by the manufacturer or its distributors and shall be available for inspection applies, the job sI at all time. The engineer needs not reseal the copies. 8. l ailure to comply with any section of this Acceptance shall be cause for termination and removal c Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPT?.NCE Helmy A.Malcar, P.E. -Product Control Examine Product Control Division r Eastern Metal SuuplY •Tnc. SCANNED ACCEPTANCE No. ' 00-0919.10 St. LUCB COUntjAPPROVED 06/07/200I EXPIRES 06/07/2004 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONTS ------------ 1. SCOPE . This approV6s- 0.030" Galvanized Steel Storm Panels Shutter, as described in Section 2 of th Notice of Acceptance, designed to comply with the South Florida Building.Code, 1994 Edition fc Miami -Dade County, for the locations where the pressure requirements, as determined by SFB, Chapter 23, do not'exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION This'0.030" Galvanized Steel Storm Panels shutter and its components shall be constructed in stric compliance with the following documents: Drawing No, 00'252, titled "24 G Steel Storm Panels", prepared by Tilteco, Inc.age Galvanized 13erth y, dated Iul-10, 2000, last revision #1 dated April 3 2001, sheets I .through 9 of 9, signed and sealed by Walter A. Tillit Jr.,. P.E., :bearing the Mid - .... -:...,,Dade:,County-Product-COntrol.aPprQvaI stamp with.:the 1,Intice.ofAcceptance,number.and pMami date.by-14e;Miarni-Dade County -Product Control Division. These, documents shall.hereinatter be referred to as the approved drawings. . 3. LDETA•TIONS All permanent set components, included but not limited to embedded anchor bolts, threaded cones, metal shields, headers and sills, must,be protected against corrosion, contamination and damage at - - all times. __ -_ 4. INSTALLATION This 0.030" Galvanized Steel Storm Panels Shutter and its components shall be installed in strict compliance with the(approved drawings. 5. LABELING Each panel shall bear a permanent Iabel with the manufacturer's name or logo, city, state and the following statement:;"Miami-Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for; building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance, 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this N installation. otice of Acceptance, clearly* marked to show the-.¢omponents selected for the proposed t 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFB C) in order to properly evaluate the installation of this system. iyeuny A. Makar, P.E. -Product Control Examiner Product Control Division - - _�_ ' I M I A M I'DADE MIAMI-DADE COUNTY, FLORID., METRO-DADE FLAGLER BUME)IN( BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAGLER BUILDINC 140 WEST FLAGLER STREET, SUITE 1601 PRODUCT CONTROL NOTICE OF ACCEPTANCE (3os) A 9 1 pqR 3 370-156i Eastern Metal Supply, Inc, 3600 23rd Ave., South CONTRACTOR LICENSING SECrIon Lake Worth,FL 33461 I (305)375-2527 FAX(305)375-2558 SG CONTRACTOR ENFORCEhMgTDrMjON BY - (305)375-2966 FAX(305) 375-2905 Your application for Notice of Acceptance (NOA) of: St, Lucie Coun PRODUCT CONTROLDIVISION 0.030t' Galvanized Steel StormPanels Shutter (305)375-2902£AX(30��372-6339 under •Chapter 8 of the Code; of Miarni-Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Mi County Building Code Compliance Office (BCCO) under the conditions specified herein. ami-Dade This NOA shall not be valid; after the expiration date stated below. B.CCO reserves ure this es the, right to sec product or material at ahy time from a jobsite or manufacturer's plant for quality cc product or Material fails to perform in -the approved manner,,BCCO may ntrol testing, If this revoke, moth use 'Of •such•product or material immediately.- BCCO resdrves.the.•right tr oke,mvoodi approval, n it is fy; or suspend the determiged by BCCO that this product or material �aiis to meet •the requirement's of..the South "Florida Building Code. _r e ei pens., of such testing y7il1.. 'oe incurred by the manufacturer. 1 ACCEPTANCE NO.: 00-0919.10 EXPI PES: 06/07/2004 Raul. Rodriguez Chief Product Control Division THIS IS THE COVERSHEET SEE ADDITIONAL PAGES FOR SPECIFIC AND GENER A7, CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami -Dade County, Florida under the conditions set forth above. Francisco J. Quintana, R.A. ',r Director APPROVED: 06/07/2003 Miami -Dade County Building Code Compliance Office t ' I 1L•0�50001k.Dc200011,emPilte.lnouce aceepance cover poe.d., Internet mail address: postmaster@buildinpcodeonline.com Homepage; http:/IRry'}\'.huildinnrnrio�.. r.:... ___ y': iY• •'' r � J 1 yi 1'ro..duet Re.vze AffiOf "imw may' • 5t Lucie.County, PnbllcW.orksrD'epart'memL' �ORI�A Code Compliance--iJIVIS1,03y �; D� t +"l �♦/�',�yy'jj4,]],�{{,�;;"} 'he .following products will be installed in thestructure located at uc u6A nl` luilding Permit # )wners Name Reserve Homes LTD QWller`S !S ddreSS':' 97l1l1.Re's'eriner, ` " ` ' GontractOr:.:. �4ddress 21,60 NWaRe Xersve P3l� xYsee ' .ontractor Kotter S1.Rnature Aomee Product Design, Manufacture; !`Model -Number 1iZ�ehodno£A�t9tschkme�llt," Pressures. Windows x 435/43.6 Ist Choice Norandex 437/438 TAP COT unit thru buck to 2nd Choicenr'fPu..ua 14(,3 _!E(,'3 L �o�, ��_ 1,5� maeonr l "embedment mia +fixed Glass - 435 .4.36 1st Choice oSrand x 3n 38 ' TAP CONwkunitthrul,b<iFrklbo�5 2nd Choice'iu �rr�d 4S s 1 �~Si �fi �Z nl�D y s3 rry rr r SG Rsc 6l�L alaeonry Jip embad�entrmilu,` 'lass (otl'er) Butt Olais Alums t1 ='i6'Gl '-lSb� 4Sd8 sil FRe� Gtt2hs�'F,ZriS ;i�tl��vix�s�t Glass Block F�2- �� Pittsburgh '`: µ'Ar us yP.zP.lan Detail lllding Glass Doors See 1 Ist Ch, 1Ce n , 2nd Choice Pryyo�t„ , �q• 7 ��, � c-fl.W.soCL pbp • masonry 1 i; , emb,edment min, ; _, wing Type boors 1st Choice { ;All0: 7" ear: end+241' - 2nd Choice nr, t Gen liroduct Benchmark (2 if10 7{ ea endf24'.`"o'c , _,.., )verhead Garage Doors, Ist Choice 4-•S5 —S- a c e= 8 C E 2nd Choice each -Bracket" a 'r ooling.Materia'1 Asphalt/Fiberglass Metal OtherRkfBG.�iA cutters. • Choice ✓� i! rsT�•1/ tr have reviewed the above componentsaand cIadding, and,have apip{9� ,g �,ln� �sG�ttura to rovide adequate resistance tofhe wind leads acid forces speclfied�b e'mr taco` re=p>¢o},i�i"off I `,1A1 r�— r r f _l.f� Si6��EW ,{l v.,r'y�1�,`.zj �•}�=r!F ^' _ 1 arne;� L. N/1`•, 1 -I �'ii5 �- St<giIatLLru^•,.J - t 7.H.. - 1°�S Ce ti I [ro �t *ejfA, f x _Q )esign Firm e,- 561462=1553 Design Certificadon for Wind Load Compliance This Certification is W he completed by the pmjcct design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessary structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovatinns (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistancq please contact the Building Inspection Office at 462-1553 or 462-2172. Project Name L7£ 'Pl AT83 office Use Only Street Address Mu.LLkr.Z Ca Permit Number Tatae— I OccupancyT Construction Type Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box:) I. Florida Building Code 2001 Edition �_ ASCE 7-98 2. Building Design is (check one) Enclosed X Partially Enclosed _ Open Building 3. Building Height: �`4t i tt 4. Wind Speed Used in Building Design: (� 3 secondgust S. Wind Exposure Classification (refer to exposure tables In Building Code identified in Line irl):5l�t�bf�iZ� 6. Average Wind Velocity Pressure on Exterior Faces of Structure E0 PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure PSF S. Importance/Use Factor (obtain from Building Code): I 9. Loads: Floor PSF Roof/dead PSF Roofnive SS PSF 10. Were Shear Walls Considered for Structure (check one): Yes X No `(if No, attach explanation) 11.Is a.Continuous Load Path Provided (check one): Yes No (if No, attach explanation) 17. Are Component and Cladding Detail Provided (check one): Yes u No _(if No, attach explanation) 13. Minimum Soil Bearing Pressure: 25 00 PSF As witnessed by my seal, I hereby certify that the information included with this certifrEmt:an fs-tru correct, to the best of my knowledge and belief. Name: _R. QtAIN1N -1 t gnuSp qfi, a Here, SEP 1 0 2003 •' - Design Rffn: G I�ssoeax-mS Date: SLCM1 I:orm tf 02(L00 I'd SOLI 294 ISS 01S 2uyuoZ 9uipling e6S=6o 20 80 Jew SEP-10-2003 14:53 772 469 9505 97%' P_nd �09/17/2003 00:11 7722837229 NISAIR AIR CONDITION PAGE 09 FORM 600A-2001 Code Compliance Checkil'st. SCANNED Residential Whole Building Performance Method A -t R Ne County ADDRESS: ,PORT ST. LUCI,E, FI PFRMIT #: -RA_9•I r\rGrr T�ATV1\I C0t•tAwTr/Y\I ww�iw� � - . _. .._ ..-._._ "���_� w, yr �r��• COMPONENTS 3EC'f70N REWlREMERTSFOREACH C710E .,,�_: __ .. ..'_.. .... fuWmum:.3 dwsg tt.baridgy area; ;5 CW$g.R. door area. Caulk gasket, weathersmp m seal 6i�lxctn wlndm�urJdoas B names,. surroursang wan; CHECK 8 Doors 806,1JIBC.1.1 BMefior a Adjacent Walls 608.1,ABC,1,2,1 fmmdstlon & wall sale or sIR place; joif6 tie� e*ior wall panels at corners; ufiAly wkratlona; be w+ waR ponem a twboltom Imo; bohmeen weRs end floor. EXCkpj'ION: Frame wells where 9 corffi�uous Infiltration harrier Is InstaIL-cl ft m tends ._,. �. from and is sealed to'tiie fot mastsn to the topplaw. . Fbom fU6.1 AB0.1.22 . Penetragons/openinge >t78" •seated unless backed bytrisa or joint memti rs. - EXCEPTION: Frame floors wham a continuous fnfdit iwt border Is Inafalkd ftud lns4tled Oftejrlv/elbaoeill „ , _ � dmm, rags; penehahorre of eeRing plane oTtap Ilaor; afOrltld ehafte, Ceiinge 6WAABC.123 some, chirrgreys eablrrets sealed M ooridr uous eir terrier gaps fafgyp bawd & tap'plate; afilo aeeess� PXCEPTION Frame cerlirgsl4hcra a congruous infitlregon barrier Is Imdaliedfhmt k sealedat`llie -`et _ seams.---, 7jrpe IC ra(sQ wtth no perleGi dGrs`eeakd,; W Typo IC ar norFfC rated•,rratdaA¢d Irrside'a Recessed UshtingFbQtm Wm ABC.124 ��t��1"1/2"ci2arence a'3"troni insulation; or Type lctafed wNhe2ocAn rrom swill Ocoee. testeri,�- Irba .o -, of9lopr caNly belwai�tfloms.' .- M Houses 6Dfi.1ABC.128 Addidafal IMiftralion regts 608.t.A90.1.3 E1dmllst {ens vented to outdoors, dampers; comb Epee t)ea em Compry With NFPA, hoeooal_._.. air •..,.;, '..._ :,;.. .: - GA-Z2 OTHER PRE SC PT MEASURES, ' ; mu3! be'�m`et;oir exceeded b alfreeidjgp2, .,. _. 'REIiWREMENTa i '''.j , ; COMPONENTS. - CHECK Water Heatom S12.1 Compy wlttl CfflCielwy requiiemems In Tatiie 612 Swddi or clearly rnaiiw okcuft )-IllksS lie provided E ar buN!-In li ! ma re u' A. Swfmming Pools a $pea 812.1 �9pas A heated.pose moat Ifiiva covers (emiepl sdsr Iroated) kikr i frimerdal poolo met have a pump bmar, Gss'spe 8 pool heaters must hwa a minimum thermal' aftlew o -78 .. Showemheado 612.7.�_ _ wow flout must t>a rsstiieted to no mere than 2.8 �.Ilorre Dam minyra�t 80 PSIG. AIr.DWbuion Systems 610.1 AR ducts, fillings; mediarileal equipmentend plenum chamber; stiaR be -mecum ly alfeched, seated, llisu. ", end Installed in aaordance with fhe CMft of Section 610. Duds In u edoned etgcs_R-8 min. IrrsulMlom . HV C Corrhds ,1 S "' rate "-1 acce'ssitile", 'tut. L ihot, tlCthermoetet loreeohsystem. I��n W4,1, 8r121 CelUrgo-Min, R49. Common wmllr Fmme R-11 or CBS R3 bo81 sides. ComnMn'09Ring a tkiuis R=11. ' EncWGaugeTM DCA Form sWA-tom Entv9y[,qu9eWl8RES`2W1 FLRCSB V3.30 09/17/2003 00:11 7722837229 NISAIR AIR CONDITION PAGE 08 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST. LUCIE, FL, WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier -- - ._ - 3 2564,00 7692.0 40.0 0.94 3 1.00 2400.34 1.00 72M.0 A9441t Total: 7201.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Hot Water = Total Points Points Points Points Cooling + Heating + Hot Water = Total Points Points Points Points 12252 3300 7B92 23244 8924 5402 7201 21528 PASS:1 Enegj'3*U9e^t DCA Form SMA-2001 Erff71&upWlaREV2D01 FLRCSB v3.30 4 09/17/2003 00:11 7722837229 NISAIR AIR CONDITION PAGE 07 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:, PORT ST. LUCIE, FL, PERMIT#: I BASE ... ....,. , AS -BUILT Winter Base Points: 5289.4 Winter As -Built Points: 10415.9 Total Winter X System = Heating Total X Cap X Duct X System X l7re" = Heating Points. Multiplier Points Component Ratio Multiplier Multiplier Mui. plier Points (DM x DSM x AHrn 5259.4 0,6274 3299.8 10415.9 10415.9 1.000 1.00 (1.088x 1.160 x 0.92) OA65 ' 1.140 0.455 . 1.000 1.000 ' ' . 5402.4 6402.4 Fn*WGGU9e— DCA Form 6MA-2001 EneWGel4e"aREV2001 FLRCSD 13.30 09/17/2003 00:11 7722837229 NISAIR AIR CONDITION PAGE 06 -FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:, PORT ST. LUCIE, FL, PERMIT V. I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Poirds Overhang _ Floor Area Type/SC Omt Len Hgt Area X-WPM =Point .18 1930.0 6.20 1813.2 Siogie, Tint W 1.0 ' .14 -''27.0 1380- "' '1.06 404.1 Single, Tint W 1.0 10.0 ' `45.0 13:617 1.00 620.4 ' 6ingle, TM W 1.0 7.5' 25.0 13.80 1.00" 344.9 - Orion. Tint N . 1.0 25 `226`. - ,16.30 - _ 0.99 . _, . 2dM Single, Tlyd N 1.0 1.0 e.0 1638-, 029 91.3 ' Single, Tint S 10.0 1.0 20.0 10,86 _. 2.29..__.,_498.6 Single, Tint a 8.0 1.0 68.0 10.88 2.29 lW5.2 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 617A 1.80 1110.E Co' no,tte, Ink Insai, l3dedor 42 1'(34.0 3.28 3S9ti:9 Ededor 1134.0 260 2M.6 Concrete. Int Instil, Adjacent 4.2 347.0. 2.0e 71.4.91 -Frdine; wdad, Adjacent - 11.0 -270.0 1.80 486.0 BasETotal: 1761A 337B.8 As -Built TataL•" 1741.0 4867.7 DOOR TYPES Area X BWPM = Points Type Area `X WPM Points: Adjacent 0.0 0.00 0.0-. Extedar Wand 17.0 7.6D 1292 Fxtednr 1710 5.10 86.7 Base Total: 17.0 88.7 A44bugt Total: 17.0 129.2 CEILING TYPESArea X 8WPM = Points Type R Value Area X WPM X WCM = Points Under Aft 1630.0 0.64 979.2 Uhler Alto 19.0 1630.0 0.87X 1.00 1331.1 Base Total: 1630.0 979.2 As.Buin Total:. 1630.0 1331.1 FLOOR TYPES Area X $WPM = Points Type R-Value Area X WPM Points Slab 195.0(p) 4.9 -370.5 Slab -On -Grade EQge Insuhftn 0.0 195.0(p 2-50 487.6 RO aed 0.0 0.00 0.0 Base Total: .070.6 A&BOin Total: 196.0 487.E INFILTRATION Area X BWPM - Points Area X WPM = Points 1630.0 .028 -420A 1530.0 .028 428.4 EndgyGage® DCA Forth 600A.2D01 EneWGdggeWFlsRES2W1 FLRCSB V3.30 09/17/2003 00:11 7722837229 NI5AIR AIR CONDITION PAGE 05 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST. LUCIE, FL, PERMIT #: BASE AS -BUILT Summer Base Points: 28720.1 Summer As -Built Points: 28121:9 Total Summer X System = Cooling Total X Cap X Dud X System X Credit = Cooling Points Multiplier poirds Component Ratio Multiplier Multiplier Multiplier Points (DM x D5M x AHU) 28121,9 1.00D (I.M x 1.160 x 0.90) 0284 1.000 8924.4 28720.1 0.4286 12282.0 1 28121.9 1.00 1.177 0.284 1.000 8924.4 EneyyGalge- DCA Fonn 600A-2D01 Sr&VjGeuge&TzWRE52001 FLRC9a V3.30 e9/17/2003 00:11 7722837229 NISAIR AIR CONDITION PAGE 04 FORM 600A 2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:, PORT ST. LUCIE, FL, PERMIT V BASF,_ . .. Aa'B�JIhT 11- ..: . _. . GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Paints .10 1630.0 26.79 70".8 Single, 71nt w 1.0 1.0 27.0 47.90 0.54 704.7 Sing%, Tilt w 1.0 "10.0 45.0 47.90 0.99 2143.9 Single, Tint W 1.0 7.6 --25.0 47.90 0.99 1181.6 Single, Tint N . 1.0 : 2.5 22-5 24.4E O.es 481.8 Single, Tint N 1.0, 1.0 .6.0 24AS 0,72 106.2 Single, Tint S 10.0 1.W.: • , 20.0 39.84 0.49 378.7 Single, Tire S 8.0 1.0. - " 68.0 39.84 .' 0.48 1287.5 Aa•BuSt Total:... WALL TYPES Area X BSPM = Points Type R-Value Aria. X SPM_ Polilt§ Adjwmt 617.0 0.70 431.9 Concrete, I t Insul, Exterior 4.2 1134.0 1.16 :_, • • 1315.4. Exterior 1134.0 1.90 2164,E Concrete, Int I(isul, Adiscent 4.2 347.0 0.64%--1 . 222.1 Frame, Wood, Adjacent 11,6 Zma 0.70 two Base Total: 1761.0 2696.E As43ulltTotal: 17e1.0 7726,8 DOOR TYPES Area X BSPM = Points . Type Area, X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Woad 17.0 7.20 12A FaQttlot 17.0 4.80 01.6 Base Total: 17.0 81.6 As -Built Total: 17.0 122A CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM - Points Under Altic 1530.0 213 3268.9 Under Attle 19.0 1530.0 282X 1.00 4314.6 Bose Total: 1530.0 3260.9 As-Buin Total: 1520.0 43%0 FLOOR TYPES Area X BSPM = Paints Type R-Value Area X SPM = Points Slab 195.0(p) 31.8 4=1.0 Slab-On4rsde Edge Insulation 0.0 195,0(p 31.90 -6220.5 Raised 0.0 0.00 0.0 One Total: 4201.0 AS-Sunit Total: 195.0 .0220.E INFILTRATION Area X BSPM = Points Area X SPM P Points 1530.0 14,31 21894.3 1530.0 14.31 21894.3 E.MWGaug& DCA Farm 800A-=l Er gyGIOUgeVFIaRES'2001 FLRCSB 0.30 05/17/2003 00:11 7722837229 NISAIR AIR CONDITION :v-17M Mott, PAGE 01 91/7103 S PAGE /PCt •'rV/S ONE 2 FORM 60OA-2001 FLORIDA FOR Bl Florida Department of Cofnmmnity Affairs Residential Whole Building Performance Method A Proleet Name: THE TORREY PINES MODE Address: City, State: PORT ST. LUCIE, FL Owner. KOLTER SIGNATURE HOMES, INC. Climate Zone: Central Builder. Permitting Office: Permit Number. Jurisdiction Number. KOLTER ^.. I. New conatrucdoo or adsdng New _ 12. Cooling systems 2. Single family ormutddamly Muld-family — a.CcntndUnit Cap:36.Qk13hArr 3. Number of units, ifmuld-"y 8 ' _ SEER: 12.00 4. NumberofHedroamR 3 b. NIA _ 5. is this a worst case? _ ye — 6. Conditioned floor area (fN) 1530 (F T o. N/A 7. Glass am&tyM Singlepano poublePane — — a.G7earglass,.do&uktJ-factor 0.011' o.oiF _ 13. Heating systems b.l)rsulttint -` o, Labeled U of SHGC 2135P 0.0M — aEleetrleHeatAtmp Cap:36.OkBtn/hr — 8. Fleor typo - 0.0 M 0.0 ft° HSPfi 7.50 —• b. N/A a. Slab -On -Grade Edge Insulation _ R—o.o,195.0(p) ft — b. N/A _ a. N/A — o. N/A — — 9. Wall types _ 14. Hot niter systems— R-41I1X0IV — a.EleddoR®stanm Capg0.0:ps11ons .Conofetalutlocal,Adjacen b. Concrete, R-4A 347.0 e' _ Wit: pgy c. pram? Wand, Adjacent Wood, , Adjacent R-11.0.270.0 fP b. N/A ..�'.. — d. N/A — - — a. N/A a. Conservation Credits 10, Caillns types (H11,11eat recovery, Solar — a, UnderAtdo R-19.011530,0 fe _ DHPdledleated heat pump) b. N/A 15. HVAC atcft a. WA — (CF-Carling Sn, CV -Cross vcntilalion, _ 11. Ducts _ HP -Whole house Am a. Sup: Una, M; Con, AEt Interior Sup. ".0, 125.0 S — Pf-Programmable Thermostat, b. N/A 1 I-C-Multizouo coding, MUfi Muldzone hesdag) Glass/Floor Area: 0.14 Total as -built points: 21528' PASS Total base points: 23244 I hereby certify that the plans and specifications covered Review, ofthe,pians and - by this calculation a compliance with t Florlda specifications covered by this Energy Code. ` calculation4ndlades compliance q� PREPARED with the: Florida Energy Code. Befo4gopstruotlori Isoompleted DATE: - / 7 - thi..sbuitding wilt ba inspected for I hereby certify that this bul g, esigneo, is In compliance:wlth' Section 553.908 compliance with the Florid Ene a FlorirJe Statutes. �bq tom' OWNER/) BUILDING OFFICIAL: DATE: DATE: EnergyGeuge® (Version: FLRgS5 v3;3.0) System 9 Room Load Summary 1 Bdrm #2/Bth 266. 7,592 99 3-6 597 7,735 2,451 352 352 2 Din Rm/Kit 425 7,414 96 2-5 634 3,799 2,301 173 173 3 Liv Rm 360 10,188 132 3-7 463 8,164 1,072 371 371 4 Mstr 480 11,066 144 3-6 496 6,419 2,940 292 292 BdrmBth/Laund System 1 total 1,531 36,260 471 26117 8764 1,188 1,188 System 1 Main Trunk Size: 16 in. Velocity: 851 ft./min Loss per 100 ft.: 0.089 in.wg Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh Room Room Length: 32.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 480.0 sq.ft. Supply Air: 292 CFM Ceiling Height: 10.0 ft. Supply Nr.Changes: 3.7 AC/hr Volume: 4,800.0 cu.ft. Required Vent: -0 CFM Number of Registers: 3 Actual Winter Vent.: O' CFM Runout Air. 97 CFM Percent of Supply.:. ::. 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air; Velocity: 496 ft./min. Percent of Supply: ' -0 "P/, ` - ' Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 59 _ CFM Actual Loss: 0.158 in.wg./100 ft. Actual Summer Infil.: - 34 CFM-' W -Wall-14E-4-8c 13 X 10 130 0.152 4.6 593 1.6 0 213 E -Wall-12B-Obw 16 X 10 146.4 0.097 2.9 426 0.2 0 26 E -Door-I1 D 2 X 6.8 13.6 0.390 11.7 159 8.2 0 111 S-GIs-1A-cb-dshgc-0.75100%S 64 1.080 32.4 2,074 37.2 0 2,378 (2) UP-Ceil-1 6D-1 9 32 X 15 480 0.049 1.5 706 1.2 0 588 Floor-22A-pm 61 ft..Per. 61 1.180 35.4 2,159 0.0 0 0 Subtotals for Structure: 7,284 0 3,335 ,Infil.: Win.:58.8, Sum.:33.6 610 3.177 1,938 0.908 1,394 554 Ductwork: 0.200 1,844 0.200 146 1,070 People: 200 IaUper, 230 sen/per: 2 400 460 Room Totals: 11,066 2,940 6,419 Detailed Room Loads - Room 3 - Liv Rm (Peak Method) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 20.0 ft. System Number: 1 Room Width: 18.0 ft. Zone Number: 1 Area: 360.0 sq.ft. Supply Air: 371 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 6.9 AC/hr Volume: 3,240.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 124 CFM Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 463 Umin. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 39 CFM Actual Loss: 0.112 in.wg./100 ft. Actual Summer Infil.: 22 CFM W -Wall-I4E-4-8c 18 X 9 122 0.152 4.6 556 1.6 0 200 S -Wall-1 4E-4-8c 6 X 9 14 0.152 4.6 64 0.1 0 1 N-Door-11 D 3 X 8 24 0.390 11.7 281 8.2 0 197 N -GIs-IA-rb-o shgc-0.35 100%S 30 1.080 32.4 972 25.9 0 776 (2) W -GIs-IA-rb-o shgc-0.35 3%S (2) .. 40 1.080 32.4 1,296 81.3 0 3,250 S-GIs-1A-cb-dshgc-0.75100%S 40 1.080 32.4 1,296 37.2 0 1,486 (2) UP-Ceii-16D-19 20 X 18 360 0.049 1.5 529 1.2 0 441 Floor-22A-pm 45 ft..Per. 45 1.180 35.4 1,593 0.0 0 0 Subtotals for Structure: 7,203 0 6,435 Infil.::Win.:39.0, Sum.:22.3 405 3.178 1,287, 0.909 926 368 Ductwork: 0.200 1.698 ". 0.200 146 1,361 Totals: 10,188 1,072 8,164 Detailed Room Loads - Room 2 - Din Rm/Kit (Peak Method) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 25.0 ft. System Number: 1 Room Width: 17.0 ft. Zone Number: 1 Area: 425.0 sq.ft. Supply Air: 173 CFM Ceiling Height: 11.0 ft. Supply Air Changes: 2.2 AC/hr Volume: 4,675.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 86 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 634 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 40 CFM Actual Loss: v 0.330 in.wg./100 ft. Actual Summer Infil.: 23 CFM S -Wall-14E-4-8c 13 X 11, 143 0.152 4.6 652 0.1 0 11 N -GIs-1A-rb-o shgc-0.35 100%S 15 1.080 32.4 486 25.9 0 388 N -GIs-IA-rb-o shgc-0.35 100%S_ ., 20 1.080 32.4 648 25.9 0 517 LIP-Cell-1613-19 25-X.17 425 0.049 1.5 625` :.1.2 0 521 Floor-22A7pm 38 ft..Per.. 38 1.180 35.4 1,345 0.0 0 0 Subtotals for Structure:. 4,850 0 1,587 Infil.: Win.:40.3, Sum.:23.0 418 3.177 1,328 0.907 955 379 Ductwork:: 0.200 1,236 0.200 146 633 Room Totals: 7,414 ; 2,301 3,799 VQ,U"IOYUII IYIYUO. I ILI,...,U. VHL.UIIGIILiGJ. 1 Room Length: 19.0 A. System Number. 1 Room Width: 14.0 A Zone Number: 1 Area: 266.0 sq.ft. Supply Air: 352 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 8.8 AC/hr Volume: 2,394.0 cu.ft. Required Vent.: 0 CFM Number of Registers- 3 Actual Winter Vent.: 0 CFM Runout Air: 117 CFM Percent of Supply.: 0 % RunoufDucfSizei " =` "• "% 6 in. Actual Summer Vent.: 0 CFM .RunoutAir.Ve(ocdY,- _ .`.. ' __. ., 597 ft./min. Percent of Supply: 0 % Design -Loss: ; ,; ;•-.-• 0.100 in.wg./100 ft. Actual Winter Infil.: 38 CFM ActualLoss:•. •_., 0.228 in.wg./100 ft. Actual Summer Infil.: 22 CFM E -Wall=14E-4-8c 16 X 9 92 0.152 4.6 420 0.3 0 25 S Mall-14E-4-8c 2 X 9 18 0.152 4.6 82 0:1 0 1 S-Wall-128-Obw 9 X 9 81 0.097 2.9 236 0.0 0 4 E-GIs-1A-rb-oshgc-0.352%S 26 1.080 32.4 842 80.3 `O 2,087 E -GIs-IA-rb-o shgc-0.35 2%S (2) 26 1.080 32.4 842 80.3 0 2,088 UP-Ceil-I6D-19 19 X 14 266 0.049 1.5 391 1.2 0 326 Floor-22A-pm 44 ft..Per. 44 1.180 35.4 1,558 0.0 0 0 Subtotals for Structure: 5,069 0 4,626 Infil.: Win.: 38.2, Sum.: 21.8 396 3.177 1,258 0.909 905 360 Ductwork: 0.200 1,265 0.200 146 1,289 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 7,592 2,451 7,735 ;Izttvde�Restdehtlal,F�f tit4`o"ekrl'0'tQE1�TAG•LQ�tfS� :^::�%His;3::„"£��w�„xxr,;w:v�^..�,;,;Js�„-: System 1, Zone 1 Suminary.Loads (Peak Method). .... .. ....r.. .::>Sn,..:.:.g.:.J_,.r S2?�'[%1a...>% ... .S. '"';t:aR:<?.2 .a`aY. y.>.[:✓YT;:?a^:n..:. oS�:.y: ..: a' a;:;va;.c:,, na ... 5;. JJ>fi:;. .:3.; J'>�?<�:ysyi::''..o.. �,.,., ..osn...er..%�.,.a.;.�q:.:::.<F:2::;?:�:;a::ixx>•F.'w: y�... ::i'a,,....A'> :.c.,.ag,:oJ:.,a.< �. .:...es. s. .<,gms<:3>:.rx.^ sJ,.:a 'yy..:..k:. «. ??J>:E.>.� 1A-rb-e: Glazing -Single pane, operable window, reflective, 157 5,086 0 9,106 9,106 metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, white or reflective color drapes with tight weave with 25% coverage 1A-cb-d: Glazing -Single pane, sliding glass door, clear, 104 3,370 0 3,864 3,864 metal frame with break, ground reflectance = 0.32, outdoor.insect screen with 50% coverage, white or reflective color drapes with tight weave with 25% coverage. :. 11DDooi-Solid Core 37.6 440 0 308 308 1.4E-4-8c: Wall -two courses brick, brick on concrete or 8 1303 5,942 0 799 799 inches concrete, 8 inches of 140# concrete with R-4 board insulation 12B-Obw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, 227.4 662 0 30 30 no board insulation, brick finish, wood studs 16D-19: Roof/Ceiling-Under attic or knee wall, Vented 1531 2,251 0 1,876 1,876 Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-19 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no 188 6,655 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 24,406 0 15,983 15,983 People: 4 800 920 1,720 Equipment: 3,200 3,200 6,400 Lighting: 0 0 0 Ductwork: 6,043 584 4,353 4,937 Infiltration: Winter CFM: 176 Summer CFM:101 5,811 4,180 1,661 5,841 System 1, Zone 1 Load Totals: 36,260 8,764 26,117 34,881 ..�,�. saae•:c,<:a:zrr<:x[;:J;..,i•:�<o2>::%::. ): [:%:aJ.::.::<J,s.: Supply CFM: 1,188 (4.7 AC r) CFM Per Square ft.: 0.776 Square ft. of Room Area: 1,531 Square ft. Per Ton: 527 ... ,. \..,.. .. ... : .. .. ... \<.. i.. \)A.; ., .»v, 3 ;.. .,... >nM iaJ.,,:.".)e.C):<:4:<..�.':i ;..YT »i a.'^xJ.Na. C..C. U)'r'Ctil V'aaR[fl.<tt<N^..., ..xa ....i.:..,. ..:�.,, ..a ..{2. , .. M, >.:.: . gl. ... �:.:..%:x?.?: ..aS., a.: uc�.y..2..2: 2..;%ti 3.``w:;�:.x:. .+«hS'?.:. :�OTJ�>�i7At'�B.a.S:.,>^,>...^ ...�:n[,,.�..:...,.�ss..:$::.,;,n,».a,.:og.,:i,.ask£a^.x.^a...a:6a.:?.'<:ox.»^....,....a>......,.>..>...a>:>.. .. �:;.: >•�2`�':»>).)... ...a. <.;:>: s. Total Heating Required: 36,260 Btuh 36.260 MBH Total Sensible Gain: 26,117 Btuh 75 % Total Latent Gain: 8,764 Btuh 25 % Total Cooling Required: 34,881 Btuh 2.91 Tons (Based On Sensible + Latent) :...:y ....... . ,v:J\n.C'J'n)>'.»'U.J:')\<. < .<payv,:C.,,..J:[n:i>:.::.... :>:.::.:..::.. �v: ....:.,v..\ ,\l,:< 'm .. �>':..�.�•.�i:'.np .\:R. Y<Yai: >. �•\;a. ,.,�.... nv .';aF.xax.>n.?.::<.,:> ...z. S\c,\. ..`<.[a.,h:x.a, xi; i\3t>'\•i.\•«i'<'2:S>'O x:�n\\Aa<[`afi\�\, :.. '[i`[\:C<y.. .S.�,An a;?a. CJ. �.,\ \h\.> \�1 �•C.`�J.>y..,L. ..w�T"U')n:F)C; ,: Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. metal frame.with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, white or reflective color drapes with tight weave with 25% coverage 1A-cb-d: Glazing -Single pane, sliding glass door, clear, 104 3,370 0 3,864 3,864 metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, white or reflective color drapes with tight weave with 25% coverage 11 D: Door -Solid Core 37.6 440 0 308 308 14E-4-8c: Wall -two courses brick, brick on concrete or 8 1303 5,942 0 799 799 inches concrete, 8 inches of 140# concrete with R-4 board insulation 12B-0bw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, 227.4 662 0 30 30 no board insulation, brick finish, wood studs 16D-19: Roof/Ceiling-Under attic or knee wall, Vented 1531 2,251 0 1,876 1,876 Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-19 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no 188 6,655 0 0 0 insulation below floor, any floor cover, passive, heavy Subtotals for structure: 24,406 0 15,983 15,983 People: 4 800 920 1,720 Equipment: 3,200 3,200 6,400 Lighting: 0 0 0 Ductwork: 6,043 584 4,353 4,937 Infiltration: Winter CFM: 176, Summer CFM: 101 5,811 4,180 1,661 5,841 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Torrey Pines Mod. E Load Totals: 36,260 8,764 26,117 34,881 Square ft. of Room Area: 1,531 Square ft. Per Ton: 527 Total Sensible Gain: 26,117 Btuh 75 % Total Latent Gain: 8,764 Btuh 25 % Total Cooling Required With Outside Air: 34,881 Btuh 2.91 Tons (Based On Sensible + Latent) ��`wS\ 3\s a � .oi \ ":ii...:,." 65 x e. "�� `ai �' haYa 5'`\,>�a\a �\. , ,..,�.cz a'fC a z Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. metal frame wdh break, ground reflectance =. 0.32,.' outdoor insect screen with 6b% coverage,.whlte or,. reflective color drapes with tight weave with!25% ` coverage 1A-cb-d: Glazing -Single pane, sliding glass door, clear, metal frame with break, ground reflectance = 0.32, . outdoor insect screen with 50% coverage; white or reflective color drapes with tight weave with 25% coverage 11 D: Door=Solid Core 14E-4-8c: Wall -two courses brick, brick on concrete or 8 inches concrete, 8 inches of 140# concrete with R-4 board insulation' 12B-Obw: Wall -Frame, R-11. insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 16D-19: Roof/Ceiling-Under attic or knee wall, Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-19 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy dry or light wet soil 104 37.6 1303 227.4 1531 188 3,370 0 3,864 3,864 440 0 308 308 51942 0 799 799 662 0 30 30 2,251 0 1,876 1,876 6,655 0 0 0 Subtotals for structure: 24,406 0 15,983 15,983 People: 4 800 920 1,720 Equipment: 3,200 3,200 6,400 Lighting: 0 0 0 Ductwork: 6,043 584 4,353 4,937 Infiltration: Winter CFM: 176, Summer CFM: 101 5,811 4,180 1,661 5,841 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 36,260 8,764 26,117 34,881 . -"_. __.._...� --rr., _..... Square ft. of Room Area: .,,.... \-.., ,. „I 1,531 ,., , .4..'. ,... ...' t., Square ft. Per Ton: 527 .. ... ,... ::::< .£ a.. .c.,.>.a.....,. S..§�§ :.:...>... .d..,. ,,. <n. . n..:.,5.>:...:...A..,,. . .. .,..§...>.t?4 ... ....�.£�. .,,.. ... .<� _, ...P...h....4t t .. .c..:...d:.� a..._.............. )b.>xu>..:!..oZC.4�...... .............. ........................ Total Heating Required With Outside Alr: :.e.: v..:...:.Y,u .5,..n . . .�.... ...z4.,z 36,260 ..>.. ..��......:.v... Btuh G.....�.....,.....r.....§... ...............r::a..:,..<.....:..£,...�aR.:..§.....:.e..t3>�:.>:.>....;:a:o;�:t..:t: 36.260 MBH Total Sensible Gain: 26,117 Btuh 75 % Total Latent Gain: 8,764 Btuh 25 % Total Cooling Required With Outside Air: 34,881 Btuh 2.91 Tans (Based On Sensible + Latent) aaicuiations are oases on 6tn editon of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I Load Preview Report Building 1,531 26,117 8,764 34,881 36,260 471 1,188 1,188 Zone 1 1,531 26,117 1 -Bdrm #2IBth 266 • 7,735 2-Din Rm/fUt, 425 3,799 3-Liv Rm 360 8jI64 4-Mstr Bdrm/Bth/Laund 480 -6,419 8,764 34,881 36,260 2,451 10,186 7,592 2,301 6,100 7,414 1,072 9,236 10,188 2,940 9,359 11,066 -471, i:ii; 1j-8-8 I- 99 352 352 3-6 96 173 173 2-5 132 371 371 3-7 144 292 292 3-6 ik Miscellaneous Report 4c u 3u 72 3.44 :Summer: 90 78 50 75 Al no Use Schedule: Roughness Factor: Pressure Drop:, . Minimum Velocity: Nlakifnum Velocity: Minimum' Height: Mabmum Height: Yes c�0.00300 0.1000 in.wgJ100 ft. 650 ftJmin- 900 ft./min—' 0 in. .0 in. Infiltration: 'Volume of Conditioned Space: Total Building Infiltration: Total Building Ventilation: Yes 0.01000 0.1000 in.wgJ100 ft. 450 ft./min 750 ft./min 0 in. 0 in. 0.700 AC/hr 0.400 AC/hr X 15109 Cu.ft. X 15109 Cu.ft. 10,576 Cu.ft./hr 6,044 Cu.ft./hr X 0.0167 X 0.0167 176 CFM 101 CFM 0 CFM 0 CFM —System 1— Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (I A 0 X 0.999 X 30.00 Winter Temp. Difference) Project Report Project Tale: Project Date: Client Name: Client Address: "Client City: Client Phone: Company Name: Company Representative: Company Address: .Company City: -Comgariy: Phone;" �' The Torrey Pines Mod. E Thursday, May 08, 2003 Kolter Signature Homes, Inc. 2160 Reserve Park Trace Port St. Lucie, FI. 34986 772-4684703 Nisair Air=Conditioning Jose 1501 Decker Ave.- D404 Stuart; Fk-34994 772-283-0904 DailyTemperafure Range: High Latitude: 27 Degrees Efejration: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 0 72 0 Summer: 90 78 50 75 61 Square ft. of Room Area: 1,531 Total Sensible Gain: Total Latent Gain: Total Cooling Required With Outside Air: Square ft. Per Ton: 0.776 527 26,117 Btuh 75 % 8,764 Btuh 25 % 34,881 Btuh 2.91 Tons (Based On Sensible + Latent) aaicmanons are oaseo on 8m eamon otACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. "The Torrey Pines Mod. E HVAC Load- Calculations 1 .. for -Kolter Signature Homes, Inc. 2160 Reserve Park Trace P.or Sf. Lucie, FI 34986 Prepared By: Jose Nisair Air Conditioning 1501 Decker Ave.- D404 Stuart, FI. 34994 772-283-0904 Friday, May 09, 2003 ENERGY PERFORMANC LEVEIJ: (EPL) DISPLAY ARCD ESTEVUTEA ENEZtGy PE$FQ NCE SCORE* = 85•j � 'I'hc hgherthe:gcoret themorc �clenY:theltomo: KOL rER SIGNATURE HOMES, INC.,, PORT ST. LUCIE, FL, 1. New eonsb1wgvn or eadsdag - New _ 12. Coaling syslama - 2. Single amuy or maid fam ly Multiahmtly — .' a. Central Unit Cap: 36.0 j1 h thr 3. Numberofunih, i£mu@i,family a — SPEW 12.00 4. Number ofBedrooma 3 b, N/A — 5- is tlde 8 wvratcago7 _ yes — 6, Coadltkaed Boor arm (As) _ 1530IV a N/A — 7, Glass area & type ,,, Single pane Doubla Pane — — s. Ckar- single Peae - 0.0 its 0.0 fN 13. Treating eyetems ..• b. Clear • double pans 213.5 As 0'0 W — a. meotrio Had Pump Cap:36.0 kBb Air o. TumUothor SHOC • single papa 0.0 fN 0.0 iv.,._ _ HSP$: 7,50 d, Tha/other SHGC-double pane b. N/A _ 8. Floortypea it. Slab-Oa4irade Edge Tmadafino R-O.o, 195.0(p) R — o. N/A b.'N/A a. N/A 14. Horwmarsysroms — 9. wall types _ a. Elecula Reaimmneo Cap: 40.0 gaON ona • a. Conomte, int Insul, Enerior R-.4.2, 1134.0 fe — 13F 094 b.'Conerata, Tm Tnsal. Adjawat R-4?. 347.0 its b. N/A — a,'Frmne, Wood, Adjeomt _ R=1I.0,270.0 A' — d. N/A _ _ o. Conearvation creft -' a N/A (HR Hod moowry, Solar 10. .Ceillagtypea _ DHP•Dedoadodboat pomp) a-UnderAnic R-19.0.1530.0f2 15. HVACoradis b, N/A _ — (CRCallipg fen, CV -Cross venblador" _ c. N/A HF-Whole hm® fmy 11. Duate — .PT programmable Thermostat, a. Sup: Una. Ret Con. AH:Interior Sup. R-6.0,125.0 it — m-GMuh zone owliag, b.N/A M&H-Mah me heating) I cm* that this home bas ootnplied with the Florida Energy Effiicienby.Code For -Building: Construction through the above energy saving featues which will be.iusiallcd:(or:t�coeeded) in this home before $ on. Othonvise, a neiv EPL Display Card"wU]: be completed based or lasta116et features. Biffldcr 53gttatm a: late: 9 z5-o 3 iatv6 133 Address of Now Home; 1GArJ CLyyLV- CltyMZtp:ML1 FL1 WV194- **VOTE The home's estimated energy performance score is only available through the FLARES computer program, ' ThisisnoraBuildingEnergyRaring.lfyourscoreis80orgreater(or86for'a-USEPA/DOEEnerguStmWdesignation), year home may qualm for energy efficiency mortgage M* incentives. ifyow pbtaina Florida Energy Gauge Rating.. Contact the Energy Gauge Hotline at 3211638-1492 or seethe Energy Gauge-tvab site at www.fseavef eda far information and a list of certified Raters, For information about Florida's 1 netgy E,[j aiency Code For Building Construction, contact the Department of CommvnityAffa ,y�'4rraion: FLRCSB v3.30). 4)6�s r_ �YIoD�"L E. Equipment Schedule Unit# 1 SEER / 0 HSPF� MakeNNOons 3 Cond.Unff Mod.# Q�34 A/H Unit Mod.# �B.27IIZi—T� Heater Mod.#��� O� Sensible Cooling ,�26 2,?O Latent Cooling 1 8'O O Total Cool BTU's n.3— 6�x 0 0 O 29/16/2003 23:50 7722837229 NISAIR AIR CONDITION PAGE 98 FORM BOOA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ( ADDRESS:... 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST PERMIT #: - ... CrIECK COMPONENTS 8E _ REQUIREMENTS FORFACH PRACTICE. 6�arbr Wir4wm & Doors— 606J ABC.1.1 MRn1LIm:.3 clln/ea Ry+lnduiw erea..6 oMMsd.R door arm. ., Caulk gasket, weatherstrip of fieal between. Y�didervs/doors & tsmaa, surroundkg wall; ..... 9harlor a Adjaoem Walls WB.1 ABC.1.21 foundation & war a* or sill plate; joints between erderbrwell panels at Comers; ub* penetration; between well panels & topftdwn plates; between walls and poor. EXCEPTION: Frame wells where d continuous infiUralim barrier is installed Rmt extends fromand lesealed to, Mrs founda6en to Bre.top plate. Floors •. ..6116.t ABC.1.22 pwzft tionlopeningsr116- sealed unless backed by trues or)oint members. EXCEPTION: Fame Room where a continuous MItraft barrier Is Initeked that Is sealed mttla meter.banebaMarrs and seams. .. Between we9s & Callings; PeneMsMms of ceiling plane of top floor: amLmd shaft, Chases, Collings 808.1.ABC.123 Saw, Chimneys, cabin is sealed to continuous ak harrier, gaps in gyp board & top plate; ate o apooes, EXCEPTION: Frame DAMP where a continuous Whaw barrier Is ifrtldlkd tfrat Is sealed tMw and seeps. Type IC ra WlihM penetialiofhe eeakvi; or Type IC Gr non4C ruled, InshW kdde a Recessed Whting FIAur@s WSA ABC.1.24 aeeled bon with 1 @- ctaemr`ice & 3 from Gffiulanon: or Type IC ruled with e 2 0 Oft from coedi'd'oned spade, feetedr .. �, .. .. 0 ,. mei4of rcawNbehaeenfoura• _. Exlmrst tare Vented to outdoors, dampers: combustion spade heaters domplywnh NFPA, . Muth•. .Houses 608.1,ABC.126 •, Additional IrAftflon regia WS.1.ABC.1 S have'eomtxrshoir ak. SA-220THERPRESCRIPTIVE M U Es must De met orexceeaea o all f65 rICfIGC3. . COMPONENTS SECTIQN REi)11 EMEt,ITB ,,_ _ CHECK Walor Healers 612.1 Comply with efficiency requirements in Table 0.12 Switch or clearly marked Circuf , or cutos) must be pn Mccl Friona) or bulfan hest aaR..__ qrd Icer elechk ) cutoff foeei Spas & heated pools must have CGVare (except solar healed), Nat-comMarclal pools Swimming Pools 8 Spas 612-1 must have a pump timer. Ciao spa.& pool heaters must have a minimum Mrarmai aftioncy of 78%. Shavver hC9da 6121„_ Water ew must be resMcted to m more than 26 gallons Per,l.4lnute aI 80 PSIO. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically - attached, sealed, inserted, and fnslall d in accordance with Ufa Critarla Of Section 610. Dyc1s In umconditOned aW= R-6 min. Irrsu)atlon. HVAC Controls 607.1 rate readiN ecceide manual or autematM themrostat for sae m. Insulation W4,1, WZI CellingeWh R-19. Common walla -Frame R-11 or CBS R-3 both sides, Common Gelling & floors R-11. EnargyGourm DCA Form S00A-2001 EnergyGaugaWFIaRES2001 FLRCSB V3.30 09/16/2003 23:50 7722837229 NISAIR AIR CONDITION PAGE 07 FORM 60OA-2001 WATER HEATING &. CODE COMPLIANCE STATUS Residerrtial'Whole Building Performance Method A - Details Number of X Multiplier = Total, Tank EF Number of X Tank X Multiplier XCredit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 76g2,0 40.0 0.04 3 1.00 2400.34 1.00 7201.0 AsBpNt 7oteli 7201.0 ErwgyGaugeTM OCA Form 600A-2001 EnergyGeugeWJaRE52001 FLRCSS 13.30 919416/2003 23:50 7722837229 NISAIR AIR CONDITION PAGE 06 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:,,, PERMIT #: . BASE AS -BUILT Winter Base Points: 5095.1 Winter As Built Points: 9675.9 Totsi Winter X System- - ' - Heating � otal . X 1', „ 'Gap X Duct". X System X Credit = Heating Points Multiplier Points Component Ratio MA01IO AAuiiiplier Multiplier Points (UM x o5M x AHu) 98759 1.000 (1A78X1160x'1.11) OA55 1.000 6171,8 5095.1 - 0.627a 3196.7: 9675 9 1 AO 1.388, , . 0.465 1.000 =28 EnMYOW90- OCA Form 800A-2001 Encrg GaugvV1FIaRES'2001 FLRCSB V3.30 09/16/2003 23:50 7722837229 NISAIR AIR. CONDITION PAGE 05 FORM 60OA-2001 11 WINTER CALCULATIONS Residential Whole .Building Performance Method A - Details I ADDRESS: ... PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Om[ Len HM Area X WPM X WOF = Point 18 1847A 6.00 198.2 Single; rat NW 20 1.0 %0 15,30 0.99 e18,0. Single, Tint Sw 13.0 1.0 36.0 1238 1.57 M9.9 Singk; Tint SE 6.0 1.0 9.0 11.49 1:94 200.4. ;Sliiglg, Tlnt SE 2.0 Co /-1.0 24.0 11.49 1.82 602.9 - Single, Tint 6E 7.0 84.0 11.40 1.94 1425.1 Sirigk, Tint SE 7.0 1.0 40.0 11.49 1.94 690.7 22T 4530.9 WALL TYPES Area X BWPM Pafrlfs T�ypp R-Value Area X WPM = Points Adjaeent 7020.0 1BU 1830,0 Conpebe;.lntlnsul Exterior - 4.2 830.6 326 2063,8 "Exterior 830:0 2.00 1280:0 Cerrorote -int lnsul, Adleead - 42 860.0 2.06 7761.0 +! •:;'. Frame lNood Adjacent 11.0 170.0 1.80 308.0 's:Baae Toteip., .... ,7960A,. .'.: ,a095:0� xAs�ulk Tafal, "�, 1660A, Mika POOR . f. Area X WPM = Points AdJicerd 20:0 4.a0 80-:0 Ext'erWIn'sulsted 20.0 5.10 1020. -. EAeior - 20.0 ..5.10 '102.0j, Adja` wk InsuMW '20.0 4.00 80.0 8892TP41: 4o-p ., ,.-.. ,182.0 As�uiWlf,Tofel . .: 40.0 1B2.0 :.CEILING TYPESArea X BWPM =`Point§ Type,-Value1. X WRM X WCM = Poiifts ,Area Under ARic ' ` 1083.0 0.04 89BA lJnder AlBo ' • 18.0 1093.0 O.WX1.00 9509 -One TC"L•. 100310 "9.9- ,� Asaul@ Total: 1M.0 9509 FLOOR TYPES Area X SWPM R-VaIuB Area X WPM = Points 'Slab 165.1 •' 4.9 �73.5 re 4iI bn,Gde Edge Insumm - 0.0 155.bIo ' 2.59 412.5 Retied ,�0.0 0.00...0.0 .. ' Base Total: .713A As43ullt Total: 105.0 412.5 INFILTRATION Area X BWPM = Points Area X WPM = Points .;:"., .,.,_ .. ... -AD47.0., s.:-,O.7B, ."._•G77.2s ¢..a,., ��.: ,...;:-.•.: ,... t:,.; .:,...;:.�..., ..1847.0: ' -0.20- -617,2 EnergyGauge® DCA Form B00A-2001 Ener9jGQ49WM0RES=1 FLRCS9 V3.30 09/16/2003 23:50 FORM 60OA-2001 7722837229 NISAIR AIR CONDITION PAGE 04 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details BASE AS -BUILT Summer Base Poinits. 34121.5 Summer As -Built Points: 30312.1 Total Summer X System. = Cooling Total. X ¢ep X : Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Paints (DM x DSM x AHU) 36iZ2 1.000 (1.087x1150.X1.10) 0,284 1.000 118"3 34121.5, 0.4266, 14556.2, 3D372,1 , 1.00 „ , ,1,.375 , 0,284 1.000 . 11844.3 EmpyGauge- DCA FwM 600A-2D01 ErmMr- WNWFIeRE$ 2001 FLRCBB v3.30 k Mi- 06 O O jr x, xm rn it co � � �.-� � � � r � C .� � 1 sty 'Dr ,� � f � s � •off 1`i i .� ji- 5y it - Ir 9 mmmm'Zl Q !m 74 00o Don >> 0 = W Tl N O'is JG G O' O G m m _ D .1 m m m m X mm q N NN a (J y M oaW - x � oa0000 �A�u�- tD 0 11 11 11 11 it 11 1y� O_ N O m � LD N m N' X m 0 D N m w U N In m r J J N J N TT Ll (C2 a m i o 0 C H D =a Oz C7 Z y1 N O CL z y• D FORM BODA-2001 FLORIDA ENERG," �lE C-AiN�C'Y CpD�E'` FOR BU'1WIN G CONSTR11' :Tin`N Florida Departrnent:of:Cornmun ty;Affairs Residential Whole Building Perform,nanCe Method'A Project Name: THE TOWNHOME MOD, D2 Builder. ... KOLTER Address: permitting Office_ city, State: Permit Number. Owner. KOLTER SIGNATURE HOMES, INC. Jurisdiction Number. Climate Zone: Central 1. Newmn,Ntruct(ohorwdsdn6 New .:11`,CanlingrysOems.:.._.. 2. Single family or mul04hrai►y Multi-fumIIy _ a' Central Unit Cap. 36.0 kHbrlhr 3 Number of units if mub ty g 4. Numbarofi3cdtooms _ 3 S. is this it worst tam? vas 6. Conditioned 9nor etob (Se 1647 Ji' 7. Glass area & type Ringlo Pane Double Pane _ a Clear glace defaultU-raolo_r D.0 iP 0.0 If _ b. Dcfisulttitd 227.0 tN 010 ft% _ o. Labeled U or SFiGC . D.0 & 0.0IF S. Floor WON a Slab•On4lrada Fdge insulation _ R=0.6, J65.0(p) ft _ b. N/A a, NIA _ 9. Wall ty1m a. Conctomtgtlnsul,.F.>naribr R=4A 630.0 A- b. Concrete Int7=4 Adjacent R-4A 550.0 lY a. Forma Wood, Adjacent _ R=11.0. 170.0 fl' d, N/A o. N/A 10. Ceiling typo m UndorMa _ R-19.0,1093.0 h? b. NiA c. NIA _— 11. Ducts a. Sup: Una. Rot 11ne. AH: Ado _ Sup. R-6.0, 150.0 ft _ b. NIA Glass/Floor Area: 0.12 b. N/A' e. N/A' 13. Hemins sysmms a. Rlccbio Heat Pump b. NIA o. NIA 14. Hotwaterayatemv a Flcctrio'Ras]satnco b. N/A SR6R:i12.00 Cap: 36.0 fcebt/hr _ F15PF:7,50 Cap: 40.0 OW3 _ PJ 0.94 o. Cmiso vw ion atodib (11R-Heet'recovery, Safer DIN-Dodlcecd hear pump) 15. HVAC amdb (CF-Ceiling fnq:CV-Cross venbilation, BF-Whola bousa fan, PT -Programmable Thermostat, M&C-Multizone cooling, M7 H-Muhhcano hoisting) Total ps-built-points: 25157' Total base points:25445 1 hereby.orUfyihatihe plans and specifiDaUons covered by this calculation are in compliance with the Florlda' Energy Code_ PREPARE DATE: A - I - 2r.>o 1 hereby certify that this bull , s designed, Is in compliance with the Florida e. OWNER/AGENT: DATE; PASS RevleW of,t.4wplansand sp6.011aati6i-povered bythis ��stas oalpulatlonit7dieates comphancer' , i °�° WIUi:the Flprida�Energy.Code Befofe conshuctlon'is completed this:bgilding.wiltbe inspect;( for.. a compliance;with-Section"5531908 " Flortda.Statutes. ooD ws MIMING OFFICIAL: DATE: FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area:.5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; - foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and Is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous Infiltration barrier is Installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 - Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic acc¢ss. EXCEPTION: Frame ceilings where a continuous Infiltration barrier Is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1 ASC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC nx a lnstalled inside a - - - sealed box with 1/2" clearance & 3" from Insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. _ Multi -story -Houses ° _ - --606.1 ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional-Inflltration,regts 606.I.ABC.1.3— -- -Exhaust-fans vented to outdoors, dampers; combustion space heaters comply with NFPA',' - - have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply wlth efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 512.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficliency, of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, Insulated, and installed in accordance v4th the criteria of Section 610. Ducts In unconditioned attics: R-6 min. Insulation. HVAC Controls 607.1 Se orate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R3 both sides. Common calling & floors R-11. FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:... PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 40.0 .0.94 3 1.00 2400.34 .:. • 1.00 7201.0 As -Built Total: - 7201.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + . Points=.;"-•".. Heating + Points, Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 14566 3197 7692 26445 11863 5705 7201 24769 PASS FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT Winter Base Points: 5095.1 Winter As -Built Points: 9032.5 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component . Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 9032.5 1.000 (1.078 x 1.160 x 1.11) 0.455 1.000 5705.4 5096.1 0.6274 3196.7 1 9032.5 1.00 1.388 0.455 1.000 5705.4 ._y FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , . PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1847.0 6.86 � ".1948.2 Single, Tint NV11 2.0 1.0 60.0 12.51 0.99 742.7 Single, Tint SW 13.0 _1.0 _ . 40.0 9.88 1.57 622.0 Single, Tint SE 6.0 1.0 " 10.0 9.12 1.94 176.8 Single, Tint SE 2.0 :1'•0 .30.0 9.12 1.82 499.2 -:. .. Single, Tint SE 7.6 1`.0 - 84.0 9.12 1.94 1131.5 " Single, Tint SE 7.0 1.0 ".'r40.8 9.12 1.94 721.3 As43uitt Total: '. 244.8 ' 3693.E WALL TYPES Area X BWPM = Points Type R-Value: " Area `X -WPM = Points Adjacent 1020.0 1.80 1836.0 Concrete, Int Insul, Exterior 4.2 630.0 3.26 _ 2053.8 Exterior 630.0 2.00 1260.0 Concrete, Int Insul, Adjacent 4.2 850.0 2.06 1761.0 Frame, Wood, Adjacent 11.0.. - 170.0 1.80 306.0 Base Total: 1660.0 3096.0 As -Built Total: 1660.0 4110.8 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 20.0 4.00 80.0 Exterior Insulated 20.0 5.10 102.0 Exterior 20.0 5.10 102.0 Adjacent Insulated 20.0 4.00 80.0 Base Total: 40.0 182.0 As -Built Total: 40.0 182.0 CEILING TYPESArea X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1093.0 0.64 699.5 Under Attic 19.0 1093.0 0.87X 1.00 950.9 Base Total: 1093.0 699.6 As -Built Total: 1093.0 960.9 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 165.0(p) -1.9 -313.5 Slab -On -Grade Edge Insulation 0.0 165.0(p 2.50 412.5 Raised 0.0 0.00 0.0 Base Total: J73.6 As -Built Total: 106.0 412.6 INFILTRATION Area X BWPM = . Points Area X WPM = Points 1847.0 -0.28 -517.2 1847.0 -0.28 -517.2 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance_ Method A - Details ADDRESS:... PERMIT #: • BASE AS -BUILT Summer Base Points: 34121.6 Summer As -Built Points: 30368.9 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM X AHU) 30358.9 1.000 (1.087 x 1.150 x 1.10) 0.284 - 1.000 11862.6 34121.6 0.4266 14666.2 30358.9 1.00 1.375 0.284 1.000' 11862.6 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details i ADDRESS: , , , PERMIT #: i BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1847.0 '26.78 6670.8 Single, Tint NW 2.0 ' 1.0 . ,60.0 31.34 0.56 1052.1 ' Single, Tlnt SW 13.0 1.0 40.0 44.31 0.40 701.3 ' - Single, Tint SE 5.0 1.0 10.0 47.60 0.41 193.6 ' Single, Tint SE 2.0 71.0 30.6. 4T60 0.43 611.7 - .Single, Tint SE 7.0 1.0 64.0 47.60.,,, 0.41 1239.1 - Single, Tlnt SE 7.0 1.0 -- 40.8 . 47.60 0.41 789.9 - As -Built Total: 244.8 `• - �r`- 4667.7 WALL TYPES Area X BSPM = Points Type R-Value Area X. SPM Points .Adjacent 1020.0 0.70 714.0 Concrete, Int Insul, Exterior 4.2 630.0 1.16 730.8 Exterior 630.0 1.90 1197.0 Concrete, Int Insul, Adjacent 4.2 850.0 0.64 544.0 Frame, Wood, Adjacent 11.0 170.0 0.70 119.0 Base Total: 1660.0 1911.0 As -Built Total: 1650.0 1393.8 DOOR TYPES Area X BSPM = Points Type Area X SPM =- Points Adjacent 20.0 1.60 32.0 Exterior Insulated 20.0 4.80 96.0 Exterior 20.0 4.80 96.0 Adjacent Insulated 20.0 1.60 32.0 Base Total: 40.0 128.0 As-Bullt Total: 40.0 128.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1093.0 2.13 2328.1 Under Attic 19.0 1093.0 2.82 X 1.00 3082.3 Base Total: 1083.0 2328.1 As-Bullt Total: 1093.0 3082.3 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 165.0(p) -31.8 -5247.0 Slab -On -Grade Edge Insulation 0.0 165.0(p -31.90 5263.5 Raised 0.0 0.00 0.0 Base Total: -6247.0 As -Built Total: 166.0 .5263.6 INFILTRATION Area X BSPM = Points Area X SPM = Points 1847.0 14.31 26430.6 1847.0 14.31 26430.6 FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: THE TOWNHOME MOD. D2 Builder. KOLTER Address: Permitting Office: City, State: Permit Number: Owner. KOLTER SIGNATURE HOMES, INC. Jurisdiction Number: Climate Zone: Central 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms ' 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type a. Clear - single pane b. Clear -double pane, c. Tint/other SHGC - single pane d. Tint/other SH_ GC - double pane 8: Floor types .. a. Slab-0n-Gmde Edge Insulation b. N/A , 'o. N/A- - - .9:. -welltypes, . a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent' c. Frame, wood, Adjacent d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Rat: Unc. AH: Attic b. N/A New — Single family — 1 — 3 _ Yes _ 1847 ft' 0.0 ft' _ 0.0 ft' — 244.8 ft' — 0.0 ft' R=0.0, 165.0(p) ft R=42, 630.0 ft' — R-42,850.0ffi — R=11.0, 170.0 ft R=19.0, 1093.0 ft' — Sup. R=6.0, 150.0 ft — 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A '14. Hot water systems a. Electric Resistance b. N/A Cap: 36.0 kBw/hr — SEER:12.00 — Cap: 36.0 kBtu/hr — HSPF: 7.50 'Cap: 40.0:gallons — ,EF: 0.94'- c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits — (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.13 Total as -built points: 24769 Total base points: 25445 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: .L1 t7S� DATE: 1 hereby certify that this building, as designed, is in compliance with the Florida Energy Code., OWNERIAGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Rhuac ttesid4rrtlal YxislgbtEamsnerc�ia[ H3iAi±iaads� ` � f ''ti Gets aibvarel7euetaprn�ot.inc: System 9 Room Load Summary 4.,k�.!P.:.n\Mt.!..:.>.ctM.W.. a%b..?,..y:..,:.2...'vN.aa�. r,a., ak.J .'a.:: S ,,,>e:.'.X.�i.\>, ":. }»,t�3:%4N':��.x:�:,..:a:v i�t�}..k�F,:."¢p: sF ..a...\...,#kftrt.Ja>5w.....}.4k.ta•;.n.aabb.. .,,.>"x,\r.v::atlt•','k.[trb,...[>..f.. k"•c,\:k a.pk1..?.'e.{ .J�,..,ri:.,V.pp .>,.•.:..,.`. <Fha..''.g....a::i<'r..'.:?k`\.C.li.nx.:. ..v:rI.,'.\:.nvb,: Jvf'>:4.?: .kk�.:.:v:.?'x•`' .\:..>.3..F,.'.v .:`L;.V.>..,, a..,..x:ik3'„>:.: x».Sy. ?b ::.[>ask.>., Svn.\ ;.:",;x::':, S:., P:Qvav:...? ..i...:»..>.'i..bw .>�, .:.«,J4...,.%.<a.[.i:.x...w y,.\1;..,.`:.:a..�.\.tl.n:..\b. .1ti'?4�,.:a.•[..cn>.. .....: {.,.';:.a.,`q,.^::.:..S.,.:..Y:.ay,....b<:.>:.a.::.r.•....?rv:.?..Vvy kngGk [ :>}>..a.. k[,.:i @•a. ..:a.'.F:.:n.....te...4._N,.:a.[.O.�i.' n . . :a.f.>.v.;C.,:..Jv>rJva,:\.Pm..v\,3i:}.::!h„\C.:FJ>?[:«»SJ<.gr'4�vylwyi •.'.:'$..E. .,".!.%r}...n...,S. .x,y..a.a:[.e�.,♦t:'�e„k.::k.:,i.�!.>Ci«:o' '[. „0`•ar.:t,.f.•3.<.[.,!.. i}4.\'<.,.:.p1.%.�;u,ef.....J, : .ft.J..,QE',�,.F..[:,n..t. .,.a»'�> .,;S•r.:i�>`f:.:>k..,:PaCb••r... :.:i•>C . . >S'.�a�aa���'�".><:�\Vk.•:...[..?...Cx..,, ;:..:VOgg, C.'S�[:C ,- a> :n<,...,..'?.!`...a:...:. >:..' [3,,.J: <bv,v'.y'uf:bn.::E. r. a,:.. i[.,•S.\♦" ..aa.fv,P..vP,aa\,: f�'...[.. 5.r:.: .n,;.[ >,>n ?:1f,. ,.\r\..3 p�.J.. f;..Ea4.`.k: ,o f'v Uti ;FlVf�> �•:F(�f r4g..:,... :.b. . .vVp: ..,.?:%:4r4, . f_. —Zone 1- 1 Hall 65 874 11, 1-4 221 ' 424 209 19 19 2 Land/Strs 84 1,762 23 : 1-4 240 460 438 21 21 3 Kit/Brk 200 5,806 75 2-6 461 3,979 2,012 181 181 4 Din/Liv 36011,585 151 2-6 599 5,166 1,893 235 235 5 Bdrm#3 182 3,510 46 1-6 501 2,162 1,055 98 98 6 .Bdrm #2/Bth/Hall 273 4,716 61 2-5 636 3,815 2,020 174 174 7 Office/Den 143 3,978 52 1-6 526 _ 2_,269.- . 633 103 103 8 Loft 154:' 1,782 23 1-4 448 859 419 39 39 9 Mstr BdrmBth " 364 ' 10,034 130 3-5 .610 5,482 - 2,445 249 249 System 1 total 1,845 44,037 572 24,616 . 11 124 1,120 1,120 System 1 Main'Trunk Size: 16 in. - - Velocity:' 802 ft./min Loss pet 100 ft.: 0.079 in.wg yy�� i%'?' y� ')q:r..;.K;.4> +. [K.. \•kc».n )� J .rk. >.�.:. Qb>,. Sb ://:.o: .: .GG ..b'.�:5 .. .. H�.(..i..i..:.:.n .:.>`...3. ?'ni>fi�a?ia:':i>':f::P; :f?3�}. tf �;:?" Cf' .,fib,:f31. n.>"v.v..3..,of:Y;b:S>'Va)�?�IEIE:3Ya\,.•::v .,n4[ ...S. R:bT ... .. 4,..J.:> :::.F;;>..:, ka..4.J .. tk!0>.`,::>.. k..4iT: C[r.>.:>.:::.,;. a..> rxtl."' .R:,:>' :vv.[r..?: .. d n: .: ...., :. ,.xEv.':. .•,: '... ,:: _. . :.:..:... P.. .ubV>.. N Off.:., nY:?'Rr,.,':.j:k: ��".`gY:P:Gi:3kabr]b:.`('b:G:rNk• `G:.:b.:6'b:G`G[b:ckxG:c:b:ri. .:. •>1!.'^xnJ;xo>:o:J:b�[bx. \ ,y G4 tr�;.f....u.,.�o. �Fa...:bitt:G3<x;,,. '.b ' �..x:::f::S�.:. E,�. tr.>2?![ 8:-:. [.i �.:: ••�22:f?k' .. ... ... [. n....: .5.. .... ....:. ,:.:.'.. .. . �: y:;.::<.>;. '�AC7inf.[ ,c.4,k... , k✓::'E> ., �:�;o,?,:fr.:J3:4>:.u.:4,":'�.>i:....... f�1�F'. .....» %f:..>..:.:• .... . :Oo <o...<. ,n: :n...; ...:, ."?:a.v. s..zc....,?k..,[`ra.. .:3 .:. r[so .a.. .. %..> [;k: ?by<:•:r:.'>�':�. ..xA:,:[,: [:....:�.. <:k%'G'?.^:k. }f?`>:<:%mk .;::'ortk}':k. n ?:<°ak%. .:4>no..::.S..bn..,...3:...::..%4:?es..[..G.,....::n n ...'�.......% ...a_a:o4.G.:.1,.:... [ •. .. .�fi9>n..n.:n�.:.. ..y[[ Net Required: 2.98 69% / 31 % 24,616 11,124 35,740- n.o •.4n..a., b>., i?b.:iT::>i:bi:trp;;ifs:bii kb:bi:bbS:b":'A::;b;kb .< :.J,J':>:f ?[:•, .>.b. v.:.S T. .0 :.�'[J:C?.:3?.r �.>':.rY.r ': �it4i{iA:a[k�'(i L,.t %::fx:, n •.> '.. . .. .. ..fe xi f.:....... .....�:...,.a.........:..,.nC.o.......v..v..%.o:!a.9..: n;.. Heatina System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh Rhvacv'[tesi�d�evn2Elarj&Ltg �nmuererciatEftr�ser;: z; ��„N�,,�;�, <> � Y 1:Gtesalfiratrsl7�eryvetaprl�enf,��iiyt�c+y _ '��IIPI���-I Yllie ihhiY>2 Lab. Y b# f Y/ b•54 bT i�'�v3'3.. Y �'"`3 '; `3T `� f 311���iB��Y[t V'. .5 Detailed Room Loads - Room 9 - Mstr Bdrm/Bth (Peak Method) xz..eY :.. a4f::.. ..2>., .,.2 ,a:::�`,!:2 :� >du.:.'u :\: 'S'!a\.. vttio-y.. , 2`:P >.... .<>.,. \v..: ....�f.L2:a>. ��,.Y.A s: .::?.Y,`a.<.. C. . ......: \. A V.. v..o\.. ,: L:.-.;.. :.;.3.. 2:.> �<.:'.`eta<\�:iEy.',! ,...a.. .y.. <. :<.> y:, .\<Y...S..Y't�t.uv�„LL..�,b:)':S::tiP:3�:>:..5•.:"<::<::i.`<vJ Calculation Mode: Htg. & clg. Occurrences: 1 Doom Length: 32.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 384.0 sq.ft. Supply Air: 249 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.9 AC/hr Volume: 3,840.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 83 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 610 ft/min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 50 CFM Actual Loss: 0.306 in.wg./100 ft: Actual Summer Infil.: 28 CFM e�.a`:s ...:tl.\'#n',.:..;vn e .NCi :..� �v 3ln2^v :.S.7<.&tbO�4�a'@Nx.' a)$a.fi E -Wall-I4E-4-8c 32 X 10 320 0.152 4.6 1,459 �I.0 --,0 331. S -Wall-14E-4-8c 12.5 X 10 95 0.152 4.6 433 - • 0A 0 79 W -Wall-14E-4-8c 7 X 10 30 0.152 4.6 137 2.4 0 72 S -GIs-I1A-rb-o shge-0.35 100%S 30 1.080 32.4 972 27.1 0 814 (2) v W-GIs-1A-rb-dshgc-0.35100%oS 40 1.080 32.4 1,296 27.2` : 0..;:i..<,.1;086' (2) UP-Roof-1 8A-1 9 32 X 12 384 0.051 1.5 588 1.3 " 0.:,. 509 Floor-22A-pm 52 ft..Per. 52 1.180 35.4 1,841 0.0 0 0 Subtotals for Structure: 6,726 0 2,891 Infil.: Win.: 49.6, Sum.:28.3 515 3.177 1,636 0.907 1,177 467 Ductwork: 0.200 1,672 0.200 118 914 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 750 750 Room Totals: 10,034 2,445 5,482 i�huac[tesldknlHfil&isfgat�nmmarciatf'iit�Rc=Loaaf�,i � Y , x '�' Y t s „t >Y ' ��tssaiw�*aarei'7eugtvlrmsiihthc ti?e�scsrrallz�daClYli�Inr^e')�Y t <3Y5;S }' S /lai3 L#.QJ' ✓JtlJa`% 4 i Y L �f f# e�il�r6�:IN1Y[iYJ y���,�,,{3fw�3 ��ff�>,,;; ����yy <.'}[j Y t, 6t RtF /;iy>�k .f t ,k 5 / iyRn •: ,.: ;.'.Y,. GT1 ": alWtl[1 CL. �S.TJQ...n>.:. .n ,, ...., .. ,...�...., _: >.:Rik2a• .., �,. ,>. G.. ...Ga.�......ary ..� >:.,, .::, u.. .J [.,a. :..,n ,... Detailed Room Loads - Room 8 - Loft (Peak Method) ...5 .. x+.... ....3�:C. 4.:''%:b �iNR[ :£9:�:X o.&.. . ,':Tf.GxS:Y':!:.> .ai3:.' G:tiiY)':t..R ;:£iE£:1:.:":^ ¢.' .. a <. ...` .:.J..ny:.W\,2...>... nny)%L\'.v;..n. ., ..... .`i:[<D'.:. r k "v:C..b. .?>: cE`E: n!Cf !:,:$. <:;�4,.cE:$: .. R'3:EpYa�n ...Y.... .vfi.. .:.vJij........,.\n.y:C^'.�,:,...[C.a:\a:�..:\„NnSJ).<9Env...�No,?.kKKn.hK\\.:� vn,J,:>CJ,:YJ<CL:tC\.:$f,..:.v'[):».J:'C.J: i:.iE>C:Jv:):<y,2..:: >:.Z..: Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 154.0 sq.ft. Supply Air: 39 CFM Ceiling Height: 9.4 ft. Supply Air Changes: 1.6 AC/hr Volume: 1,448.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 `. Actual Winter Vent.: 0 CFM Runout Air: 39 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 448 ftJmin. Percent of Supply: 0 % Design Loss: ,0.100 in.wg./1.00 ft. Actual Writer Ihfil.: 13 CFM Actual Loss: 0.227 in.wg./100 ft. , Actual Summer Infil.::.,: ' . 7 CFM > . i '<L>:RM`�Y> Z ` •' ykam�,, ��Giv >:.w' 52.<°�wL°Ge � :D >^'k' �J:ta�;a a MEMO O �y yio f. d b �.R !a E..L. <}Qv �.I,>.W\1 .3A , a,t: Y•U Qv, �.. 2\:o'i�: £O.».I:v. Y.<pFR1. J, .>S}C E's,'J. )..., a�n7'[A >'.L:'[^ :YybA:f'.. :;;RS:b.J:ML.. C..L.^ub3Y:. t.SY )x5>:Cx E..3>••`Ou ::fS<">CY�' rII.#!°i. r'':.<>P''•`•. `i:q., .,.� :'Et'>:r• siy.a:,:^?3:� vm . ..>;O>:y [Q>.4 �n ' :k� ., h 5 :.:J'wti� :Rai ..n.: >:D.. a... di ...¢.[. :..`. Es;:o::t .>.. sA,`.b,.:. T.: :nl> 8:R<:a:n>:J�i��iti.'.>:[;u:5?:.n pp ..f.:.��t�:2R:i7':171r.:..:��:):b:8:.�.RII!t:`G: W -Wall-I4E-4-8c 14 X 9.4 131.6 0.152 4.6 600n • .J 2.4 0 .JY 316 UP-Roof-18A-19 14 X 11 154 0.051 1.5 236 ., Floor-20P-19 11 X 14 154 0.050 1.5 231 1.3 0 204 0.5 0. 77 Subtotals for Structure: 1,067 b. ; 597 Infil.: Win.::12.7, Sum.: 7.2 132 3.176 418 0.904 r_3d1i 119 Ductwork: 0.200 297 0.200 118 143 Room, Totals: 1,782 419 859 ;lac ResldaenflarR�l.�gNtEomrkiere€atklY�c#.axas Y ;;�Ys;>;,v�x;at:;.>. �-<^-= t,:M.;:�;s"<sotttirai i7euero .ldc;; <i!erscr+atlzed�ervine'rnc .P r P ;.' Rb^ tC\Fy. ': C Y tiS ' t i2`' t £�i S5R i f t S y4 PR tt 'i'he'F�reo�€17: Detailed Room Loads - Room 7 -. Office/Den (Peak Method) •Eas`..` Aida v'l:fa .^::E�<; C;;1:.<. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 143.0 sq.ft. Supply Air:"-. 103 CFM Ceiling Height: 9.4 . ft: Supply Air Changes: - 4.6 AC/hr Volume: 1,344.0 cu.ft. Required Vent:[. "- -_-- = O.CFM Number of Registers: 1' Actual Winter Vent.: `_ Y _` 0 -CFM Runout Air; 103 CFM Percent of Supply.:. _ 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 526 ft./min. Percent of Supply: 0- % Design -Loss: 0.100 in.wgJ100 ft. Actual Winter Infil.: 22 CFM Actual.Loss: 0.177 in.wgJ100 ft. Actual Summer Infil.: 12 CFM yrCER ... R.R.. T::.. >.....:.::i.n,...>.<...b..s .. v.... o<..:.�<' ...., .. .:+P" ':<:.�; i%.1.. jj{{�� ��f� .4.C\ «>S�:, .M•� iRC:d::C\C. . ::>': Y, :�. .�iE�SRixi.'Oil, 'f?^!'..,'.,`,`„x..fly:;o.: �:£;S>'<:,:ry... :..1E N.. .>C..A. �, i,`^ ♦ o:;`CZ:R: `C.vbRb .<. .,.44.:. ,>:P'n. Y C,. >s:i.RRE ..0 ., .,wl ,.<s.. :#a.rb�.. <:..4. :$!£:y+"•: { e.<.}'.>1.a?D:.iE<:R:<!.vY<v::<4:<..::.. .,..4a,.<. ::oi:,..W.b 4. ., b ..,>.. ...w\:.FY.. y,.. R >4,<. '<Si:i: Ri..n:::...' Aid :.G, .S..p,. Y: �'` � �>,.P.q. . s : '.�1'F.1Jn£:°, `ww>yf,�::R7.R:R?`i �:bn px�R:" i:!£zniurc yy.L, h.,��jj ##�� 5�,� .$�,:�} >a:M:&Gt>.o:.. .... _.tt..,. £tw5lF� Si:'§R:�:•)tp:P.::... 1C..n.tti....�i�'1f1efia%a°S:Y.::,.ya'V.Aoe 1:>>(',.<...vw....Gi�{�.�ViLE.............�ltif4.:n.:..x:ff:1., ' W -Wall-14E-4-8c 11 X 9.4 103.4 0.152 4.6 472 2.4 0 248 S -Wall-I4E-r-8c 13 X 9.4 81.4 0.152 4.6 371 0.8 0 68 8-GIs-1A-rb-dshgc-0.35100%S 40.8 1.080 32.4 1,322 27.2 0 1,108 (2) UP-Roof-1 8A-1 9 13 X 11 143 0.051 1.5 219 113 0 190 Floor-20P-I9 11 X 13 143 0.050 1.5 215 0.5 0 72 Subtotals for Structure: 2,599 0 1,686 Infil.: Win.: 21.7, Sum.: 12.4 226 3.174 716 0.909 515 205 Ductwork: 0.200 663 0.200 118 378 Room Totals: 3,978 633 2,269 I Detailed Room Loads - Room 6 - Bdrm #2/Bth/Hall (Peak Method) Room Length: 21.0 ft. System Number: 1 Room Width: 13.0 ft.. Zone Number: 1 Area: 273.0. sq.ft, Supply Air: 174 CFM Ceiling Height: 9.4 ft. `Supply Air Changes: 4.1 AC/hr Volume: 2,566.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 87 _CFM Percent of Supply.:. 0 % Runout Duct Size: 5.. in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 636 ft./min::. Percent of Supply: - 0 % Design Loss: -0.1.00 in.wg./100-ft, = Actual Winter Infil.: 32 CFM Actual Loss: 0.333 .in.wg./100 fL Actual Summer Infil.: ` 18 CFM vv,vvau-74r 4>uc'Z11C8.4 197.4 0.152 4.5 900 2.4- - •0 N -Wall-I4E=4-86 14 X 9.4 111.6 0.152 4.6 509 1.4 " 0 , N=GIsAA-rb-o shgc-0:35100%S 20 1.080 32.4 648 27.2 0 UP-Roof-1 8A-1 9 21 X 13 273 0.051 1.5 418 1.3 0 Floor-20P-19.13 X 21 273 0.050 1.5 410 0.5 0.. -, Subtotals for Structure: 2,885 0 1,670 Infil.: Win.: 31.7, Sum.: 18.1 329 3.176 1,045 0.909 752 299 Ductwork: 0.200 786 0.200 118 636 People: 200 lat/per, 230 sen/per: 2 400 460 I=quipment: 750 750 Room Totals: 4,716 2,020 3,815 tl�udc [iesld0nk1a18'i9ght�fitrime�iai Ht/A�#:oacfs t� ' 3, sue; 3 �` EO%5 tivrdisT7eveCoprnenf�lir Petscmafl�e�8emee :Stu9Ttr,FT-::�x '>?x8 ,.. w:u,: xav „t:i xry z w 3 cc r; , Detailed Room Loads - Room 5 - Bdrm #3 (Peak Method) wk. ...w.w,v w:0:'. ,ax a<ox:>:n^v""a'e<:�,E ca%oi:!aav:Si[xi:.'<a.i`.a'.•a.'q ..:":\:::,x:A 'i'}�;a a.s .. .<..... ..L..; Calculation Mode: Htg. & clg. Occurrences: 1 F3oom Length: 14.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 182.0 sq.ft. Supply Air: 98 CFM Ceiling Height: 9.4 ft. ' Supply Air Changes: 3.4 AC/hr Volume: 1,711.0 cu.ft.. - Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 98 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. - Actual Summer Vent.: 0 CFM Runout Air Velocity: 501 ftJmin.:.. Percent of Supply:. 0 % Design Loss: 6.100 in.wg./10013., . Actual Writer lnfil.: 23 CFM Actual Loss: Actual Summer lnl . 13 CFM :'8Zga.v';So::k.:.5!i�:C,.. ...�. r.c.. .a... y� ..o0.vi ;..e;„'< i;a3 3,:. �;s•,::�:. ., ? .: J,3 }.,.:, o iif'i.� k`Q. >,;. JiF! a ,. "�it'Y ': i .Hr.' - ,S:af" . ia:.'.::a:wh:wxa:.>.. , v:>; .>:. .a, ui: a?a..xa x: ;. fi . ...� ..; :..'.<.>: , «:u<yy<�+x°<f.<'::: _.:. ... d;:.<V` ;`wY,:` o.:a'.6o:�o`:Kvh$.g., b;:£�. ...e\Q.,�.:< 'w�"��Y'::'.;a�'„JA �',,.A.� oR.Y.y.' c:'�x; .�.<:.................... Q.@!�..3 vo x°iw:�<wx ...(`� ;%ar.. �::Z a ':••:°" ... g .wu,EhJ.II\F\u: .o..:..:o?tt�3,uN: :c-: x.a:;('.F., HIM rig /y p' E7Wa11-1.4E-4-8c 13 X 9.4 122:2 0.152 4.6 ":: ` 557 1:0 0' 126 _ N-Wa11=14E-4-8c 12 X 9.4 92.8- 0.152 4.6 423 ' 1;4. - 0- ., 128 N —GIs-1A-rb-o shgc-0.35 100%S 20 1.080 32.4 648 27.2 r. 0. ' 543 UP-Roof-18A-1914 X 13 182 0.051 1.5 - 278 - 1.3 0-.: '-,' -241 Floor-20P-19 13 X 14 182 0.050 1.5 273 0:5 _0% 91 Subtotals for Structure: 2,179 - 0 1,129 Infil.: Win.: 22.6, Sum.: 12.9 235 3.174 746 0.906 537 213 Ductwork: 0.200 585 0.200 118 360 People: 200 lat/per, 230 sen/per: 2 - 400 460 Room Totals: 3,510 1,055 2,162 i3hvaG r7aslaeAEtdil��:lgbt�nmrtelazC HStIrOtLuai� t 3�, r ;. x ` ,� : f :> ��OtaBattvrareri7ez�er4Fment�tric Detailed Room Loads - Room 4 - Din/Liv (Peak Method) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 24.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 360.0 sq.ft. Supply Air: 235 CFM Ceiling Height: 21.0 ft. Supply Air Changes: 1.9 AC/hr Volume: 7,560.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 118 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 599 ftJmin. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 75 CFM Actual Loss: 0.229 in.wg./l00 ft. Actual Summer Infil.: 43 CFM ...:.. i . .,xx:..,.:<.:5:.°:'e:.. :5.ti:4.. .<.. .. .t. ?.r.44Xb? ,.V�:4e ..x,.... w.S... � ., :S'?>,;?iipSx;,f. xC>E>Ie al. IF., }.��ii'�i:3#...... tiiFvay, �. ,i.,....d.. ., ,....v.?Y.S? e:e .. ?. .. .'�{R.'S�i�>�.'.n Yi..:: c:£ee:c4: :::'< ...,?..,.ee`<: �3a. H;3,:a:u.S: R' :..5..:. :::.:i' � ,. .::;e:.:,e quart �:<..�.:..e.��lial�$�:<;.�'>:::r�.W...i�lzw.:.<.::<e,..�.a�<.........i<..:,�„�7. 1i"ib'ax,:'A;:�r: •e �.x;Yq'.'`• W -Wall-14E-4-8c 24 X 21 , 504 0.152 4.6 2,298 2.4 0 1,210 S -Wall-14E-4-8c 13 X 21 209 0.152 4.6 953 0.8 0 175 S -GIs-lA-rb-d shgc-0.35 1 00%S 64 1.080 32.4 2,074 27.2 0 1,738 (2) UP-Roof-I8A-19 24 X 15 360 0.051 1.5 551 1.3 0. - 477 Floor-22A-pm 37 ft..Per. 37 1.180 35.4 1,310 0.0 0 0 Subtotals for Structure: 7,186 0 3,600 Infil.: Win.: 74.8, Sum.: 42.8 777 3.176 2,468 0.907 1,775 705 Ductwork: 0.200 1,931 0.200 118 861 Floom Totals: 11,585 1,893 5,166 <Rtivac RLaJsi�pife��nt�ial &tlghtiCtfrYlnterc iAl1�A�NA @S� � k3S S.Y Y4HNCW�IfRYrw.VG�Otir��i{�iYla�ii 5 'iy YNy ` CSC 5 � 5 SS �d GCS .S Old rL,:�TJF]v?+.......ry 5` lo..+�,.+5�+,..`i>%'C..++:ti'.Y+:��•�5.1s•::::�.$<. j: ":�2r +'�'R#: �'. .i.+:.�.[',F. ��3R +S�.M, k..:>. :. ;nvo.cl +L.y+:,n...... .:.. �. Detailed Room Loads - Room 3 - Kit/Brk (Peak Method) .:ui.:2SSx:5;%::.::..':.,s:»:x::<::<: <Rk:>:<"k:rs:`. ... ....J:..>.....,...<:J,k...:. s;...:<„<. [.asa:<s.:><[...,.<..,,,;e.:\.3.,o..J:.:$k.:.. ,.. < Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 20.0 ft. System Number. 1 Room Width: 10.0 ft. Zone Number: 1 Area: 200.0 sq.ft. Supply Air: 181 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 6.8 AC/hr Volume: 1,600.0 cu.ft.. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: _ 91 CFM Percent of Supply.: _ 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 461 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 29 CFM Actual Loss: 0.137 in.wg./100 ft. Actual Summer Infil.: 17 CFM X. Jar: >. ?C..., 'i>�"."Y'a Siw?w#! ..\.\`.... .�.:.. a��R"1'wy :' 1 PJ ¢.:":y � .,, 5 >. `,��:<s „%:.5, '$'.,,5.: .,�.3aR'S5'ig.•:;,; <J:<>:r c<Rk'.. 9. ,»\. .......,.. aw ..fi�\.,y..'R.. ,. .,`.5r':>#b"a.<o.d<\'.%F`a \... 3L ,.P' ,.[<'.�a.,, ., ....,.:.W..''2.. \;.<r.o...., <.Y.J.,:.Y.y.,>, y$: >@.<P1r .y'b'.> >'o�+.>..Y k;. «Yv:<.\,.n.'4 .,j<.'.y.?Y .,3,. y:3,.>. .;,:1C\.< tk<. "+ �} bra �y �,.c>,:.k,;>,0 :£:?:' .:9 .. 'O# .. '&a.. r�?��c[,r°.[:oc��`.' ����wc... �yC�.�)»:[n.:>:C:\. �y'�'b,J1.)«: 3.:.k: a.i.,:Q,. J,%.?.'[ j 6 /� .. ,L ,.A.1Y<.� rt;::J&..r..A.:..: @C\.q :\'.: Q..: .�.�1: „\„T<.k`.(y5i��5Yn>T\k'1?/,n, ...1 <r;f. J:'�: eC:@:.J. h�.�y Y' �d�lli'#l�Ak �V.R.9.4 i:i#;;.>: T': f.n��%i:R �..,: .:. >.[.,CR>'.r ....:C�: J>.<.>:1<:1 t;;;', 'k ..`\!,f!}J. .,:.,1F N -Wall-14E-4-8c 10 X 8 60 0.152 4.6 274 1.4 0 83 E -Wall-I4E-4-8c 7 X 8 46 0.152 4.6 210 1.0 0 48 W -Wall-14E-4-8c 21 X 8 168 0.152 4.6 766 2.4 0 403 N -GIs-1A-rb-o shgc-0.35100%S 20 1.080 32.4 648 27.2 0 543 E -GIs-IA-rb-o shge-0.35 62%S 10 1.080 32.4 324 49.8 0 498 UP-Roof-1 8A-1 9 20 X 10 200 0.051 1.5 306 1.3 0 265 Floor-22A-pm 38 ft..Per. 38 1.180 35.4 1,345 0.0 0 0 Subtotals for Structure: 3,873 0 1,840 Infil.: Win.:29.3, Sum.: 16.7 304 3.174 965 0.908 694 276 Ductwork: 0.200 968 0.200 118 663 Equipment: 1,200 1,200 Room Totals: 5,806 2,012 3,979 i ]ivac Kesaiientiaf &L� 8t cmmeiGtat V . t gaits :, < - .a:: ; . ;;;:>;• ;- :: > ; ;;,a«, ; ...........E%te sQti,Ya►e i3eve mant Iris . ..^... >..... .:... ...... ..... ... .. ..... .... ... ..... .._::...\ .. ., ... /., .:..:... ,;: J:J:>.J:>^...:..:,... .. : «: ;.:. �:.%Y;.:.:n„%..,,..:. F.J.. <:..... �. 1'ersanatlzed'Serviee Ins • � '' � wx`�a � ; 9 ' $ ' " 1'hB1t�rayMocii3 Detailed Room Loads - Room 2 - Land/Strs (Peak Method) <F:[..: S:<..:i:..3'CO;,.:o:Q•.J.:[.:<::...:v:.'v.,::....va[:: �:>:.::>:Jk:. .: U�[... y...:..:...:.>.:<.:`:: ".:[.:.,. ..max:�:v>..:n..�:."..<.>k::.:`::.... £v.:. '. ...,:.... c...:..>......•�.:::ui'::9::vg,:J.9;::>:s:::'<:.:.c... ; .�k...:. .. Z:c ..... bi... ..V..v),.: $a... ... ., :.i:.....v ...v. ...^R.. ,>. ,bi.>.n .: .k..... '.� eYal.. 2,0` ..aF.9>.�kx .. ...q...<.. ,.. .: ,.;`yt¢;a oa:F`r`.:..ai?o'L,c?ah:.;.„..J.�:.aS:>:[<[>.:�>.... <.>:J;>.... .. ,vgS;`.::<•: R c �, ! a'.:... v°>i..w.;<. R �.n\>R;[[Ao.,v.. ,...Z., k.:::. ..:\.>::Y..; ...V.. h': kn \A. b.k.. ,J :t a...\....� ,...FN<.. �...:..a. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 84.0 sq.ft. Supply Air: 21 CFM Ceiling Height: 20.0 ft. Supply Air Changes: 0.7 AC/hr Volume: 1,680.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 21 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 240 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 13 CFM Actual Loss: 0.067 in.wg./100 ft. Actual Summer Infil.: 8 CFM J.> �y �i;.,�':" . J.>: `�n'F:FIM F�:.? .....[.....:F:r:.:!..' ..::�+'0.':•:£?�i,. ,.�:.. 3.i..vw. ..:..., J. �..•n.3.. .. f:.�kh,.::, u`2iFJ,. :..::.:...0 ,.Jkii' :j- it S, A::c% "1:. ,....5•: ...m, .9:::: J^ae.: >... b.:<[::. :...:�i.. :, r. .. ...:.. .. OWN ....7,.,.gig aa.:.51Y;�1�1A... .�"a'�:�.<.>>,....s....�ki:�:[^:Y:;!.[:"£: ..J. E -Wall-14E-4-8c 7 X 20 140 0.152 4.6 638 1.0 0 145 UP-Roof-18A-19 12 X 7 84 0.051 1.5 129 1.3 0 111 Floor-22A-pm 7 ft..Per. 7 1.180 35.4 248 0.0 0 0 Subtotals for Structure: 1,015 0 256 Infil.: Win.: 13.5, Sum.: 7.7 140 3.179 445 0.907 320 127 Ductwork: 0.200 292 0.200 118 77 Room Totals: 1,752 438 460 Detailed Room Loads - Room 1 - Hall (Peak Method) Room Length: Room Width: Area: Coiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Design Loss: Actual Loss: N-Door-11D2.5X8 . UP-Roof-I8A-19,13 X 5 Floor-22A-DM 5 ft..Per. Subtotals for Structure; , Infil.: Win.: 3.9, Sum:: 2.2 Ductwork: , Room Totals: 13.0 ft. System Number: 1 5.0 ft. Zone Number: 1 65.0 sq.ft. Supply Air: 19 CFM 8.0 ft. Supply Air Changes: 2.2 AC/hr 520.0 cu.ft. Required Vent.: 0 CFM 1 Actual Winter Vent.: 0 CFM 19 CFM Percent of Supply.: 0 % 4 in. Actual Summer Vent.: 0 CFM 221 ft./min. Percent of Supply: 0 % 0.100 in.wg./100 ft. Actual Winter Infil.: 4 CFM 0.057 in.wgJ100 ft. Actual Summer Infil.: 2 CFM 20 0.390 11.7 234 _ ` 10.1...`, . ... '0" 65 0.051 1.5 99 1.3 •' ,: ;. 0 5 1.180 35.4 177 0.0 _' 601 0" 40 3.175 127 0:900 91 , 0.200 146 0.200 118 874 209 203 .86 6 317 36 71 424 Fthvac ResiderRial��.lgTlt�mameraia[,HStA�ihadS r �' � x Fy qo � 5 fs�trttwarsTieveCapt►Cent.IriC System 1, Zone 1 Summary Loads (Peak Method) ,' .h...a.:\";.a. !s,'x»?c,.Y„:.. a.. � oa:!!r .ova .a.,„e[.::..v...:.: ,;�,..,.0 R'ar,:.' ,.aaa,.a....o4:a. .a. .. \..a,<f,f;o!$.,>;>, :.: %,Yc;,:. a.:Sa..,....a%• seb:.>, •:>Yf.%� . .e.9L. e. .f .A.u,.r,�....... .......,a..3. .. \5 a a v .......... .... ... .... .:,.,.%:. 6g.. 1A rb-o: Glazing -Single pane, operable window, reflective, 100 3,240 0 2,941 2,941 metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage. 1A-rb-d: Glazing -Single pane, sliding glass door, 144.8 4,692 0 3,932 3,932 reflective, metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage 11D: Door -Solid Core 20 234 0 203 203 14E-4-8c: Wall -two courses brick, brick on concrete or 8 2432.4 11,091 0 4,088 4,088 inches concrete, 8 inches of 140# concrete with R-4 board insulation 18A-19: Roof/Ceiling-Below roof joists, Dark or Bold -Color 1845 2,824 0 2,445 2,445 Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, R-19 blanket or loose fill 22A-pm: Floor -Slab on grade, No edge insulation, no 139 4,921 0 0 0 insulation, below floor, any floor cover, passive, heavy dry or light wet soil 20P-19: Floor -Over open crawl space or garage, Passive, 752 1,129 0 377 377 .R-19 blanket insulation, any cover Subtotals for structure: 28,131 0 13,986 13,986 People: 6 1,200 1,380 2,580 Equipment: 2,700 2,700 5,400 Lighting: 0 0 0 Ductwork: 7,340 1,062 4,103 5,165 -Infiltration: Winter CFM: 260, Summer CFM: 148 8,566 6,162 2,447 8,609 System 1, Zone 1 Load Totals: 44,037 11,124 24,616 35,740 ,�ce���,:;ss:'soo>.,: •a;.>: S:b:, ::n::.;.»Ca�as:s[F::;::.�::::a..[:raw:>;,»::5<;. <:,e..['Y..u3:a.. ;. .:5<:: ,. yyyy�� u%.:'��aa o: !a:.e. [cobii'a .. •>.,.., xi`A>. ...$>., 4. f;... a:..£,.v4%k.,>:..:4.:�'o:;y....,..,?:>?">,l.>:..:ua...: G%I'i' i'1u:.cE� 'S .>4<.. .>. .._..>: ... :... ...x:.f.,;!C#M.....J.x.\e.^.... Supply CFM: 1,120 (3.0 AC/hr) CFM Per Square ft.: 0.607 Square ft. of Room Area: 1,845 Square fL Per Ton: 619 O\Y MKxv .M. : ix`:5"•Y"/5: •Yr'%.a.....:..:.:a!: ::. .v.. \!oa ,.,»:::n:[;. .!.F.:.::4FxOaNLY . .:4. Total Heating Required: 44,037 Btuh 44.037 MBH Total Sensible Gain: 24,616 Btuh 69 % Total Latent Gain: 11,124 Btuh 31 % Total Cooling Required: 35,740 Btuh 2.98 Tons (Based On Sensible + Latent) UNMI QaEa .:^'.•.., .' ^^ °5 ,.ra8„rs . Calculations are based on 8th edition ofACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. system I Torrey B Summary Loads, (Peak Method) 1 A-rb-o: Glazing -Single pane, operable'window, (effective, 100 3,240 0 2,941 2,941 metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage IA-rb-d: Glazing -Single pane, sliding glass door, 144.8 4,692 0 3,932 3,932 reflective, metal frame with break, ground reflectance _= 0.32'outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage. 11 D: Door -Solid Core 20 234 0 203 203 14E-4-8c: Wall -two courses brick, brick on concrete or 8 2432.4 11,091 0 4,088 4,088 inches concrete, 8 inches of 140# concrete with R-4 board insulation 18AA 9: Roof/Celling-Below roof joists, Dark or Bold -Color 1845 2,824 0 .2,445 2,445 Asphalt Shingle, Dark Metal, Dark Membrane, Dark - Tar and Gravel, R-1 9 blanket or loose fill 22A-pm: Floor -Slab on grade,,No edge insulation, no 139 4,921 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil 20P-1 9: Floor -Over open crawl space or garage, Passive, 752 1,129 0 377 377 R-1 9 blanket insulation, any cover Subtotals for structure: 28,131 0 13,986 13,986 People: 6 1,200 1,380 2,580 Equipment: 2,700 2,700 5,400 Lighting: 0 0 0 Ductwork: 7,340 1,062 4,103 5,165 -Infiltration: Winter CFM: 260, Summer CFM: 148 8,566 6,162 2,447 8,609 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Torrey B Load Totals: 44,037 11,124 24,616 35,740 W"MU-MMMISIMM MMIMINISM Supply CFM: 1,120 (3.0AC/hr) CFM Per Square ft.: 0.607 Square ft. of Room Area: 1,845 Square ft. Per Ton: 619 MMMOMMM OWNER? NOMMOMMUNI, 10800 WMINIMINMENNON 1I Total Heating Required With Outside Air: 44,037 Btuh 44.037 MBH Total Sensible Gain: 24,616 Btuh 69 % Total Latent Gain: 11,124 Btuh 31 % Total Cooling Required With Outside Air: 35,740 Btuh 2.98 Tons (Based On Sensible + Latent) WOMEN E 3: iJ1110111. Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. uac t�asra� lal t:7glitrairanerceaLliitA�taa� �3 :^`:- _ � x F�tiiteSafhxaie CieYetopmeiitrinC Total Building Summary Loads w. k:k `p . A..:. va:?Y... v».3...�'CCk; -. .s. , f. .Sc.. .:S:�c v:'•» ;b ... , . ¢f . `:CEN:2,G�:. `ct::.> :.. .. ..4..:.. .. ..:... ).. ae:... .., v. v..., .<.. n:.. ......:£».M... y.i ...R �`. �r.f.t .::Ed.'.. . Zsa. ..Yt3.ka..d:. :.`<:[s; •:.:i.• ..k.: ...$.; a.S., a,L�:::ib:.. '.ffEtn.b w4b b:.... 3a �:. .� l!i' ...�.•,.; .'i^. ..y 1A-rb o: Glazing Single pane, operable window, refiectiye,' i 1;00:.' 3;240 i 0 2,941 2,941 metal frame wfth break, ground reflectance ='Oi32, outdoor insect screen with 50% coverage, dark color drapes wfth loose weave with 25% coverage 1A-rb d: Glazing Single pane, sliding glass door, 144.8 4,692 0 3,932 3,932 reflective, metal frame with break, ground reflectance' = 0.32, outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage 11D: Door -Solid Core 20 234 0 203 203 14E-4-8c: Wall -two courses brick, brick on concrete or 8 2432.4 11,091 0 4,088 _ - 4,088 inches concrete, 8 inches of 140# concrete with R-4 board insulation 18A-19: Roof/Ceiling-Below roof joists, Dark or Bold -Color 1845 2,824 0 2,445 2,445 Asphalt Shingle, Dark Metal, -Dark Membrane, Dark Tar and Gravel, R-19 blanket or loose fill 22A-pm: Floor -Slab on grade, No edge insulation, no 139 4,921 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil 20P-19: Floor -Over open crawl space or garage, Passive, 752 1,129 0 377 377 R-19 blanket insulation, any cover Subtotals for structure: 28,131 0 13,986 13,986 People: 6 1,200 1,380 2,580 Equipment: 2,700 2,700 5,400 Lighting: 0 0 0 Ductwork: 7,340 1,062 4,103 5,165 Jnfiltration: Winter CFM: 260, Summer CFM: 148 8,566 6,162 2,447 8,609 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total.Building Load Totals: 44,037 11,124 24,616 35,740 i :>.: ..h..$..1 �[!5:'.. ' .: Ez..,...£.II.Y'k3<>i',3...,.;:.:. c?._.><,[...>..i.o..u,...ne.. nx,::,G».,::wa::a?<..«..,.:»».:x.,<...3.,..f>.:>,al... �,�..«<.:.;u�;.x...gJ.k.',,° .:£:>�SkS:»w�;:.,>;.v..sa.:»! k:eso:::f•t<..g7:..A„!.c,,s.:�..%.>.:.:.,f,.Y.>L.<>.::.>v<.1.>.<,..k.:a...:;1. cqu£s.k:!ns<4r.<,.aG.::.r<...,.,k:.:3us::,,....:,e..0,::ao....:;[....?4.>\.....?[`:?Soga::y.c.nJ`'ax.`.a:i:tb'.....k><.•.<:...!k'::"r.?:S:>`;:a<Y.in» y .3;xkt;xxx.. Total Building Supply CFM: 1,120 (3.0 AC/hr) CFM Per Square It - 0.607 Square ft. of Room Area: 1,845 Square ft. Per Ton: 619 k.: xs:: <�� kb: .. :. .,r.x :!. :!i....�.>. £.d[[Y ...: .n: v ^P'Yy '°i3... r:?Grikts> Ii Itli i �k J,.:!k!:: »,k;[:c<;>;?ze,:>, x;>.e?:z.: Lnads::.f.. n. a. >.>: ;k.:..R..P.. <o,: .:.<.:;5.: g:. e..:...a.J:.::J :ov..>:.y,.. ..,.,........ >.,.. u:.c......n..f3..,?ak:<;>:;. Total Heating Required With Outside Air: 44,037 Btuh 44.037 MBH Total Sensible Gain: 24,616 Btuh 69 % Total Latent Gain: 11,124 Btuh 31 % Total Cooling Required With Outside Air: 35,740 Btuh 2.98 Tons (Based On Sensible + Latent) . Qo �k!;..>..: »»,...,; ...».. :i,sxf.ntlnJII.J»v: <:[ '»sx>,Z. Ak»•>«:»zJm»:3::ok<vxb'ta�i,b.J.'[:;>,::::.f.:;:n<:,;v::<'y%;:>::x::`xq.:::;3'�.':. <:z�#�::3:!.c�sy$�Y:>`y:;'::<x:';;..:Y,:•.<.. ><a::.<'co:. Calculations are based on 8th edition ofACCAManual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. W WV TTt . W N " N � 0 a iD CD N S 0I J W i i N i W N co 00 OcA V 000)000.07A A A co W N O O? N N N N N W N N W A i+. 00 W 00 N CN0 cco(n W (VOoA 0) i . i- AA000Oo C)A N-�- A i CO N CA co 3 W O N r m o W O N w w w w A•4 co ViNfJf W V0 0 N-4 0W jc011WM W A V O W V OON OfV Wi(pWO � A O Vf0 VNUf coV 000 W co V i i 0000f V W A N 00(3)O N O7 NA V i Of W N f T W A. O c V O W N�0301 W—•N N ii Ni _ A W O V f0 WN Nf i CO CD W AOD Of " icO Of A W OV co W ONf i N co co W A00(D Nsi co CD f W i i N i N N i i uf�6&1& 6 & --�- Summer: 90 ''- -. 7B "_,50 75 61.09 Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maxmum Height: Yes Yes 0.00300 0.1000 in.wgJ100 ft. 650 ft./min 900 ft./min 0 in. 0 in. Yes Yes 0.01000 0.1000 in.wgJ100 ft. 450 ft./min 750 ft./min 0 in. 0 in. Infiltration: 0.700 AC/hr 0.400 AC/hr Volume of Conditioned Space: X 22269 Cu.ft. X 22269 Cu.ft. 15,588 Cu.ft./hr 8,908 Cu.ft./hr X 0,0167 X 0.0167 Total Building Infiltration: 260 CFM 148 CFM Total Building Ventilation: 0 CFM 0 CFM —System 1— infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) .. ....^..:..,..:.:....::.:....::: #3hirae::a;Ctssldardlah3GL1 Cit:4`�urrimersi=a[::Htt. ;:Laadss'f,3i:'f$:;:ys:.frgf4:isRxy,;r'f<-:�x.x„<..k<..,%.is4>x.)<<..=J<.:>)`x`%.`»y.)x;4:«<.)`%:`.. aftwarei7evets� m4zrf<nak P:..�::.�.:,.. ^,;...,i.::..>:..;::^:<a%^:...,:«.....^,,.:.... :,.�..^...�:::...^.._........,............:^.^........,...,.:,.,...,..::.:...<.:.:.^...:.;^:;..�.>,f4x:;»asx>:..>%3:J;,hnw:;>sR.ft:«..:.x..xy>f:.....:..::::.... _.^,.^,,.....,^.^:..... C ... .ON h"i.:"31i99f�-'�99>�'.�::; u S�.£. �';..:.',.. :., .3.:. ^ : , » :� s:.r.:.: yb<:> :..s; r ..'#. 2 ;y</•s. < :<' i 4 q . �.. .. a Project Report ' A.......<...k:<o::%4..'kr'k::v':.J4::<C,'.)i �?Y: 1a::an <i:Y':::<�,: �i\':eHf..:.ny';�"'R'4:;f.�::<<':k':) ?:r ybbR.•.5�2: `fc<.4.f. ";?;`; a,.'k.;4?.. ^..8... .,.�..'2:�... .234. a.a ^e.t:b3.. .,d<1... :..R... �...:.�??:, �:f:�a.f :i::}fa.Ga.,,:,.:.a:k:�ak:...�?:i>„-;:x.,,,<�o.,,.x.,.i...>.....„<,:�.;rb;<4,>:;:�2i::�>2:.),>)�z4. Ja.. Project Filename: C:\Elite\Rhvacw\Projects\TorreyD.rhv', Project Title: The Torrey Mod: D Project Date: Monday, June 02, 2003 Client Name: Kolter Signature Homes, Inc, C[lent Address: 2160 Reserve Park Trace Client City: Port St. Lucie, FI 34986 : , _- Client Phone: _ 772-468-4703 Company Name: Nisair Air Conditioning. Company Representative: Jose _ Company Address:, 1501 Decker Ave. - D404 Company City: Stuart, FI 34994 Company Phone: 772-283-0904 ;4x.: .. y::'r „G�'.<r`,;::?:Fi >: a..f h,aG<?':,:R3s!;Ris bS:%r;i!aS)$& . �. .i... kS: `?}!«$: *... £rc'!£<:f}�:}"k?:... ::•:i•<i<?''::b2ff:: J;ixoR:.<:..a"..a, . .. .. ..a...v.. .......a.av:.\.... ..v.. <2i:. 4.u. ... ^.:>.n4.. 4....:.v.:.........is<. G.�<. b x. ..\:.. d" fi.. -Reference City:',: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 0 72 0 Summer: 90 78 50 75 61 :: .. ... ....... :.. .. o��;x22:::<.<.;)f.::s.`>:),):i��)::ry:s::<.:.•/e:: .:^.c:y>::�:...fr.��.:..::..:;:kxE kk...:x:.x::::.r`:.,:.:i..:f:::;.;:>x,2:f.:f.:`:4.::.:f::.,ky.,::«iz>:. ..2 .. .. .R., ..3. R b.2. .. ..4.:.. <.>..;.:. h:..;). .: ..3.e,. .z:...k.,xo.....: x2a5.:A....fi.:..R..x?:.t...?.:):R.R<x...'e...a.sue:.:av:e,ry.><:..k:2':c.2s:&. ...?t4 ..,:4k:n£io ....b:.r o: 4.ob.:.c `r..h...b.5rc,$) .. .::: ......« ..::::. w...o:: .:.4.ps>:v..e):o). :::«b Total Building Supply CFM: 1,120 (3.0 AC/hr) CFM Per Square ft.: 0.607 Square ft. of Room Area: 1,845 Square ft. Per Ton: 619 ...C., aY . xa.4 , .. :.. �.:. � .... .. .. <,.0: ... ..4>.. o.. .:. .. ..:. .: <...i.'<r:xz k. owo:4:ixi:u> ^k..: �j����(( �f .:.k:o?.k .) ,. ( C.. .e:}.'..k .Ai : <::%.!g<::bRi<N.`:a!Ji::>:CC<:`::2:is22<:....^..<:'o"?:`:::^.�:Sa3:��{��1� _�,DadS.. .5ryk>k4'�:).FJ,bY, tlaf:<.<:).. h/O.q. .}.......\ o.. :. i�<i2?a<:.`a tt,:x�.>f.J. :u.,�.`y4:<�.. ... .:. ..q.:.::Gi.. ..Jn:.... ).f::.: ...... .. ,...:..:. >..:.,.: <. : .^.... .. .... .... .............. :. a......,.,:. .a. .x. x...,..:.IR.M...x..s..<a...._<,..,.«..._<:.:^.�.:...:..^<.:,.,:4:<..:o..a^_....4.^^...;,3in?:3:aif<F?<.,>:..x...<..a<}:oo2a?:ES:'s,Yi�;}�t::;?A.:;<4:riff:#gb:�4: Total Heating Required With Outside Air: 44,037 Btuh 44.037 MBH Total Sensible Gain: 24,616 Btuh 69 % Total Latent Gain: 11,124 Btuh 31 % Total Cooling Required With Outside Air: 35,740 Btuh 2.98 Tons (Based On Sensible + Latent) . y:>Y':»"::O::kJ`:C ::Yi:yxu'.:%%i:>:fi["� •.)>.xF>i?::.. n:Y.x2 :x) ^.o.<N:'`:?<.. a.Yy< V .»ea'<a�v"q; 1f. , .. L....:.y ..... J'n..0 r,.?.:. ....i. .., r. .?FL>i,,.:... .<:?R..<z:iRa:$:�'kfnro � o:ox`.,d x..u.:cts:>n„q,.>..u»�x.,n.4h.. n..:.4:.:; s.�<•9s.)fi'�R:.4... .......... �zta>.....�.z^sy::"v:.:e:.:z>, A .^x..x..... .. n.a. R.A>Rau<Lx�..aa:n3.........�...d....e. .: r Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. The Torrey Mod D2 HVAC Load Calculations -for Kolter 5ignaiure Homes, Ing, 2160 Reserve Park Trace Port St. Lucie, Ft 34986 Prepared By: Jose Nisair Air Conditioning 1501 Decker Ave. - D404 Stuart, FI 34994 772-283-0904 Tuesday, June 03, 2003 ENERGY PERFOR MANCE LEVEL".(EPL) DISPLAY .-C: A" KOLTER.SIGNATUMHOMM, INC.''', 1. Now construction or existing New 12., Coolies tqsteftlg. 2. Single family or muld-braily Muld-fially 0. cantrai'Unif; CF KO Iptuffir 3. Number orunitq, if Mutti-family 9 SAWIZOD 4. Number of Bodromus 3 b. N/A 5. is Ws a worst case? Yes 6. Conditioned four area (fF) 184712 a. NIA 7. Glnm am & tpo SingloPano DDublvPanc.— a. Clear-ainglopma 0.0 fim 0.0 W.' b. Clear- double pone 227.0 W 0.0ft2:- -7 a. me ouip-HoWump Cap: 36.0 kSMJhr a. Tinvother SHriC -single pane 0.0 An 0.0 it — M '.. : I I I HSPF 1 .7.50 d. Tintlothur SHOC - double lame b. 141A S. Floortypa a. Slib-On-Grade Man Insulation -7 R-0-0, 165,0(p) ft m N/A b. NIA a. N/A 14.' Hot water qgicena: 9. Wall typoResistanceCap: 40.0 Olons L Concretk in[ rnsul, Exterior P-4A630.0 fiP ET. 0.94 b, Concrete, Yet Insul, Adjacent X-42; 85D.9 it- •b. MA o. Frame, Wbod, Adjacent R-1 1.0, 170.0 it' d. N/A o. Conservation credits e. N/A Solar 10. Ceiling typed DMILDcdicatcd bent pump) n. Under Attic -R=19.0,1093.0. W HVAC credits' b. NIA (CF-Coiling; Pan, CV-crom ventilation, c. N/A M?-Wholdbounfau. 11. DOM a. Sup.- Una. Rot Unc. AM Attic Sup. 1140J50.0.0' NZ-C-Multizona cooft, b. NZA I certify that tW3 home ]it Construction tbmugh the in this home MOM final based on installed Code c: -Builder Signataw: . I W-" aq Addrm of New Rome: Mlle ll-wiliieinswa�lexceeded)' Di9play:Caiil,will! bicompleted' Date: Ct -z- s-- 0 'S Chy/FL 23p: PS)- ) FL i 8 q4t COP, VOM* The home's estimated energy performance,.wore is only oyallable-throue rAu Ais 1sxvJ a Building &er&,RaiJ)7g, your home may qual0for energy efficiency mortgage (EMO fncenilv,6godpbit Contact The Energy Gauge Hotline at 3211638-1492:or sesihs-Enery site information and a list of certified Raters For Wormation about P7aNdaiErlergyEffi, Construction, contact the Department of Commu?IIV.Aff,7&M3fflMoqff4tlsiort!TWSB 7130) P744IRM FbrBui1dh7g 7owpa 0 M 5" Mob. b -2 Equipment Schedule SITRZZ HSPF 7- 6' Make,4�WAWY, Tons Cond.Lfnft Mod#1211,8493(6. AIH LM MocL#,1762fAf-q1 Heater Mod.#- 67e&,Zq 6SI Sensible Coollngg4j��O Latent Ong/1,200 Total lcool am OG/SLxf2003 23:17 7722837229 NISAIR AIR CONDITION PAGE 10 FORM 60DA-2001 Jested�ssaled ducts must be certified in this house. SUMMER xCALCIJLATIONS Residential Whole,`,Building Performance Method A - Details ADDRESS:, PORTST.;LVc1E, FL', - PERMIT # BASE AS.BUILT GLASS TYPES .16 X Conditioned X BSPM = Points Overhang Floor Aiea Type/SC ' - Ornt Len Hgt Area .X SPM X SOF = Paints .10 18l+S:0 2d.70 7909.8` Singk}Tlyd ' e " N 13.0 1.0 12.0 - 24.46 0.61 179.4 ". S[Nk, Thd N 2.0 1.0 40.0': 24.46 0.64 = 3 Sieyle 71nt N 9.0 1.0 25.01. 24.46 0.61 ' 373.7 E -13.0 1.0 34.0 53.27 0.38 WA SirBk�Tint - S e.0 1.0 144.0 .W84 0.48 2728.5 SUigk Tkd= S - 13.0 1.0 40.8 39.64 0.48 772.5 . 8itgk,Ti4 - S 2.0 1.0 30.0, ..39.84. - 0,50 - . 592.8 325.8 - 6928A WALL TYPES Area X `t35PM Points Type = - R-Value Area X SPM Points Adfacec7t 7070 . _ -- •0:70 �494,9 COnaeta, IM GwuI, ExA'u r 42 1645.0 1.18 1908.2 EktedM 1649A 1-.90 -31255 Condatc 6d109UI;Adj'bm-A 42 566.0 0.64 382.2 - Fia6,wb' W Adjacerd 11 11.0 141.0 0.70 98.7 Base TOW.. 23920 a 8670A As But@TWeL;" 23620 R769.1 DOOKTYPES Area X.BSPM Points Type Area X SPM = Points Adjacerd 17.0 1'.8D 0,2 E:detlorlrasulaled 24.0 4.80 116.2 Ede1Wr 260 4;80 1.1fi,2, AtlJace�d Uiwlaleq 17.0 1.60 27.2 BasaTdal: 41.0 142A As-BuiBjTgtal .. .- 41.0 _ 142A CEILINGJT,.YPES'-Area %.BSPM Points Type 'R-Value ' Area X `SPM X SGM = Points Under Attic 1000.0 213-s.2130.0 UiidarAltle 19.0 1000.0 2.02X 1:00 282010 Base Total: _..--. 1000.0;".. -. - -.-;3130.0, , A"ui im:a _ .. 1000.0 2820.0 FLOOR TYPES Area % BSPM Points Type, R-Value Area X SPM = Points Slab 11<0(p) 31',8 3625;2 SfatrOn Gtetle Edge l sulet oir _ 0.0 114.0ry .31.90 .3636.6 RaOed •,683.0 3:43-2342.7 RalsedWOod; Stem Wan- 19.0 683.0 -1.80 -1229.4 Bass Tatal: ;.59879 .As:Bfdlt TOtaL,.'-. ... 797.0 .1986A INFILTRATION: Area X BSPM Points 1.2Area X SPM = Points -.a6830 ,,14.31. 24083!7 1665.0. 14.31 24083.7 EnergyesugA OCA Porm 50DA-MI -EnagyCaVWVF.IaRES'2001 FLRCSB V3.30 r EL94;V2003 23:17 -7722837229 'NISAIR:AIR CONDITION PAGE 09 Energy Code Compliance ;Duct System Pelrtoinmance Report State: PORT ST- LUCIE, FL - :r. KOLTERSIGNATtdRE,HOMES:1NC.. Ile Zone: Central - Total Duct System Leakage Te Line System 1 Systeml 2 System2 3 System3 4 System4 5 L I T.9taI: He forrleak+free dud -system credit:. Signature: pf ir►W Name: HOW& RaterZertiflcation #: DATE Builder. KOLTER Permitting Office: Permit Number - Jurisdiction Number ofm afm arm cfm Receive crea R<o.08 III duct leakage of air to or from to`outside."'The lest :Must be ls-to-inciude.all components of regardless of location. Pressure ursystems, Include results of mon line five above. -The total .or less than 0.05 to receive requires -that „.OVI,6/2003 23:17 7722837229 NISAIR-AIR CONDITION PAGE 08 FORM 60OA-2001 ° -ode. , ,o,,m an a Checklist Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST. LUCIE, FL, PERMIT #; - COMPONEpft .. EC7.1CN 'REQUIREMEM EOR.EACH PRACTICE-.... ... - CHECK t3darbrVVhldows$.Doa�_ E06.14IiBC , mamunT3tflVe wirrdawarea�cfMsgtt.�orarw. 6g6.1 J1BC 1 21 ,:.Caulk, Waft 8 Ad*erd Walls g891te4 weathelShiP C ,seal between: ,Mnddrvs/doas & fismes, sUR dng wail; _ . foundation Br;WeA sole u siO Pete lolrlfs tieh lean ®de wwo panels -at Comm, uGlRy . 'Penstrau pMn;.bdween walls and flow. EXCEFTION: behier is instafled that exlerids ;from and.issealed to .th0 tddnd9G0a to ttie too platm. Flown t908.1.ABC 1 22 ,. %penstratiotslopemngs s1/8 :sealed uNo-backed;bytnm or jo1rd m®mbers. .. -:: fEXCEP770N Frame'llaw®"where a continuoustlifi dcn boMor Is hsEaffed tl,at Is sealed 13eiebatlonsofdellingplane oftopfbor;around ohel�;:ClleeeC,'.:. Ce�ngs t3f73.1ABC.1.23 .: - -,sclfils CtNfM1Ey�CablhOta.a_2dk'-d io coidinusuaatrtiartlee;gEps In gypboErd&toppmte; :;:etfiC acceea::EXCEP,TION:'Frarne Cdnrgs whereacongnuodsinfihiationbeRiet�ie. ....... •__-- - . :-,h191anEd theris�seiled aE live. atPenetrations-.E_nd_sbama.. BOB.1 ABC.1.24 :'typo RecessedUgtfirg Fodares IC fated with ne penetratlorrs, sealed; -:or Type1C or non -IC rated, installed inside a -...d¢aled hoX Wfth;1/2'tlearance & 3' from;hmubtbm; orType:IC:mted wfth a 2.0 Cfle from - - - � condidoned ....” tested.• � ..��.. ' .Hodses _ • 6oli. ABC125 ::- Ai�bemer%all�DeYimetel:of:flodi.CaVlNbelNnenRoom, Addlllerul.IMlttiatbnragls 6gB.TJ1BC13 ;F.idreusifansva`rdedtoouidoas,denipels;;=buofmopweheotemcompfy NFPA, ^ _ BflelgyGaugewDCAForm 6M-2u01 ,Pm4"uge&#RES2W1•FLRCSBVJ,30 T 0�/i16/2003 23:17 7722837229 NISAIR AIR CONDITION PAGE 07 FORM 600A-2001 Tested sealed ducts must be certified in this house. WATER KWINzG CODE ;COMPLIANCE STATUS Residential Whole i Building Performance Method.A - Details 9DDRESS: ,:PORT ST. LUCIE, FL, PERMIT #: .BASE A&BUILT WATER HEATINt'a Number of X Multiplier Total Tank EF NurnWrof X Tank X Multiplier X Credit • =f Total Bedrooms -volume Bodroonis Ratio Multiplier 3 .. 2554.00 76920 .40.0 0.94 9:-. - . 1.00 2400.34 1.00 7201.0 AsMaiRt-TatiL 7201.0 COMCOMP "I CE'STATUS BASE AS -BUILT Cooling + Heating'. + - Hot:VUater = . Total Cooling + Heating + Hot Water = Total Points Points Points- .. ..Points--' : Points Points Points Points 13574 3980 7692.' 25T46 983$ 7730 7201 24769 PASS EnagyGaugeTM DCA Form 6MA-2001 EmflW0aug@&+1aRE8'2D01'FLRC56 v3.30 09/-16/2003 23:17 7722837229 'NISAIR:AIR CONDITION PAGE 06 FORM 60OA-2001 Tested sealed ducts must be certfied inAhis house. 'WIN 'ER;C P LIC LATI.ONS ResidentialWhole Bulldirg PerFormaniJe Method A Details . �-:. rarcrvui BASE AS -BUILT ser case rotrtisr s s • ,tMnter l4s:Buiit Points: 14943.7 iPtMrder X System = Heating Total X :Cap X Duct X System X Credit = Heating Points. ° Multiplier Points-, •Component . - "'Ratio - Multiplier Multiplier Multiplier Points - (DM)fDSMxAHU) i343.8 , ;:0:6274 3980.,1 _- 14NU 14943 7 -L000 100 (1.=x1.000x1.11) 0.455 1107 0:455 0AW 0.050 7730.3 7730.3 u EMMYGWYew DCA-Form 000A-2001 i EnewcaG alit &mot mCRC913 w.30 C09/16/,2003 23:17 7722837229 NISAIR AIR CONDITION PAGE 05 FORM 600A-2001 Tested sealed ducts -must be certified in this house. WIN' 'EAR CALCULATIONS Residential Whole.#wilding Performance Method A - Details ALJQKF_UU: , PORT'ST. LUCIE, FL, . PERMIT* BASE AS -BUILT " GLASS TYPE§.... _. .18 X CondWoaed"X-BWPM = Points Overhang. Floor Area -Type/Sc - Omt :Lert Hgt Area X WPM X WOF;a Point d8 ''168a;0 - `689 1776Z'�"- Suigfe ._Tinb' N 13.0 1.0 120 IBM_ 0.98 181.6. { iSgfgle; Tuft N 20 1.0 , 40.0- M.38 ...: 0.09 505.2 -�€ Slijgle; 11M N 9.0 1.0 25.0 15.38 09s 378.3 -'. Single; Trrd E 13.0 1.0 34.0 13.04 132 5849 . `.. Single; Tint S 6.0 1.0 144.0 Mail 229 3589.8 Single, Tint . - S 13.0 1.0 40.6 10.88 229 1017.1 - Single,.TIM S 20 1,0 30.0 10.8E 222 724.3 -� -As$ili@Total: 326.8 7082.2 WALL TYPES Area :X BWPM Points Type R-Value Area X WPM = Points Adjecert 707.0 " 1.66 1272E Coiwi ep e,Int Insul; Exlcifor 42 1645.0 s25 .7 . Falerior 1645.0 200 3290.0 Condre _ •lnt,liisol,*Adjacent 4,2 566.0 2,08 1188.0 Frame, Woad,'AEJaoent- 11,0 141.0 1.80, 253.8 Rasa Total: _..23620 4662,a. As tiik�Total: 2362.0 6782.E DOORTYQES Area X BWPM Points Type", Area X WPM M Points Adjacent 17.0 4.00 .66.0 EMenor"Ittsuleletl'..: -..: 24.0 5.10 122A E:4erldr 24.0 6.10 1224=- 'AdjacentlosWsted 17.0 4.00 6B.0 Base Total. _. 41A ,.190A';, .-As9uiltTotal: 41.0 190d -CEI4ING7YPESArea X=.BWPM Poritt Type -, R-Value Area-X WPMXWCM= Points Under Attic 1000.0 0.64 640.0; Under Able 19,0 1000.0 0,87X 1.00 870.0 Baae TotiL• 1a00A .. .. .. "-640.0F AS43uitt>ToTel�" 1000.0 970.8 FLOOR TYRES Area X BWPM Points"° Type . R-Value Area X WPM = Points slab - r 114.Otif) . -1:9 -216.8 S,6b6C Glade Edge fi�sulatbn,- 0.0 114.0(p 250 285.0 -Ralsed -883,0 -0.20 --138.5� Raised Wood, Stem Waii 19.0 683.0 0.30 2049 Base Total: -.4632, .As-Budtt Total: 797.0 489,9 * INFILTRATION -Area X BWPM Points Area X WPM = Points -1683.0 428 4712' 16M.0 .028 -4712 Ener9YCaN94 DCA Forth BWA-2001 Ef)6WGaugeVFI8RES'2001 FLRCS9 J3.30 09/16/2003 23:17 FORM 60OA-200i 7722837229 NISASR AIR CONDITION Tested sealed ducts must be certified in this house. PAGE 04 Method A - Details I 'ADDRESS: ,:PORT ST. LUd1E, FL, PERMIT #: BASE AS -BUILT GLASS WOES .16..X Conditioned X 'BSPM -= Points Overhang Floor Area TypelSC - Olnt Len Hgt Area X SPM X SOF = Points .18". I"11.0 `26.7(1' - 7809.8'": SL1gfe, Tua . "` ... - N :.. 13,0 1.0 120 24.46 0.81 179.4 - :.:Single, Tint N 20 1.0 40.0 24.46 0.64 826.3 Single, Tint - N 9.o 1.0 25.0 2A.46 0.61 373.7 - Single -nnt E 13.0 1.0 34,0' '63.27 - 0,36 657.4 - -. _Slrgle7 Tint S 6.0 1.0 144.Q. 39.54 0.46, 2728.5 • .. Single; Tot .5 13.0 1,o 40.8 39.84 0.48 772.5 S 20 1,0 30.0 39.84 .,. 0.50 592,8 -As43uiltTote: 32l.8.6828A WALL TYPES Area X BSPM Polnts Type R-Value Area X -SPM f�oirlts Adjacet>t 707.0 l),70 4949 < Ca onlle,;Ld Insul, Fgellor 42 1615.0 1.16 19082 Eger" 1645.0 1.90 3125.5 Corwate;lMInsuI.AdjacM 42 566.0 0.84 362.2 Frame, Wood, Adjacent 11.0 141.0 0.70 98.7 Base Total: 23820 . '.8820,4 ; AsSM Total2 23820 2369.1 POQR TYPES Area X BSPM Points Type .. Area X SPM = Points Adjacerd 47.0 1t60 <27.2 I:ldcel0l.lflaulater!' _ 24.0 4.60 1152 EARrior 24.0 4.60 115.2 Agacelit lnsulafed 17.0 1.60 27.2 BaseTotal: 41.0 ..1424 A"uwxc4L•. 41A 142A CEILING TYPES;Area X ,BSPM Points Type R_Value Areaf XSPM X SCM = Points Under Attic 1000.0�2.15 :21311.0 UnderAdb 19.0 1000.0 2.82Xtoo 2820.0 F3aseTotal: .-1000.0 , . _. 2130.0: As MR Total: - . 1000.0 21120.0 FLOOR TYPEs • Area X BSPM PolntS Type R-Value Area X SPM Points Slab 114.0(P) •31:f1 34'25:2 31ab-On-pjade FAge fnsulapon 0.0 114.0(p -31M 3638.E Reif Re3.0 W3.43 -23427-- RaieedW00dr:Stem Weri 19.0 683.0 -1.80 -1229.4 ease�Tcla1: 6987.9- A9$1hlt TotmL•.- . 797.0 4898.0 INFILTRATION Area X;BSPM = points.,Area X SPM = Points 1683.0 14.31 24083.7 - - 7683.0 74.31 2408;i.7 EneMVC,augeeDCAForm =A-2001-ENWGaB* laRES=, II'LRCSS0,30 g9/16/2003 23:17 7722837229 NISAIR AIR CONDITION PAGE 01 0?%! 7 D 3 r IFORM'600A-2001 FLO F Florida Department of. Community -Affairs Residential Whole- Building:Pe rformance Method A Project Name: THE TORREY MOD, C Builder.. KOLTER Address; Permitting office: CRY, State: PORT ST. LUCIE, FI.. Permit Number. Owner. KOLTER SIGNATURE HOMES. INC. Jurisdiction Number. Climate Zone: central I . New conatructieft or misting Now 12. Codinsaymnax. 2. Single family or multi -family Wti-faunly a. CcutrzlUnit Cap: 36.0 ISbAr 3. Nrunberofunits, 1froul8-braily SEEJW12.00 4. Number ofBcdrocnna 3 b. NIA 5. In this a worst 0=1 Yes 6. Conditioned floor area (fe) MR3 RF a. NIA 7. Qlss:4"&rypi Sift&pgfle Doublapanc a. Mar ginss. dolismitUfiwbar 0.6 ft2 0.0 fo 13. Hcaftqyd=8 b.Dekultliat. 325.8 ft' 0.0 ill IL Veaft.10-Henotpump Cap; 36.0413h9hr c. Labeled U w SFIGC 0.0 W 0.0 ft2 MPF. 7,50 8. s. Slab-On-Grada,E4ge lars1don R-0.0, 114.0(p) It b. Raised Wookstcat Wnll A.2 a. N/A c. N/A 9. WallrRes y 14. Hot a. Concrett,7minsul, Exterior 31�2,1645.0 W s ElearkResistamov Cap; 40.0 gallons b. Cancretc, lathmul, Adjacent R-42.566.0 fi? FF- 0.94 e. rmn% Wood, Adjacent R-11.0, 141.0 It' b. N/A d. N/A c. WA c. Conson-aticat credits 10, coilinstaft (HR44cat nwvazy, Solar e. Under Aide R=19.0. 1000.0 AF DBF-Dcd!m&W hcak parnp) b. NIA - 15. RVAC craft Fri c. NIA (OF -Calling hu. CV-Crosa ventilation, 1). DuctageakFree) - HF-Whola house fan, a. Sup; Use, Rat: Una. AM Attic Sup, R-6.0, M.0 ft _ Fr-Programarabla Tharnnost4 b. N/A W-C-MultimmaDoling, MZ-H-MuKaDna hcaftg) s1fKloorArea, 0.19 FGlas! Total as -built polnts:-24769 PASS Total base points: 25246 I hereby certify that -the plans and specifleafiowcovered Reviewo&twplans:and by this calculation are In compliance with Florida - specifications covered -by,this * -Pe Energy calculati6ti:Indicates-.cofnpliancp.- PREPARED -i with the Before construction is completed DATE, i, b6.InspvcW for-' I hereby certifythat yils Fbui ng. as designed, is in compliance . jlanwlthoSectianr)53.908: compliance with the e. Florida. statutes. OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: EnarSYGRU901) (.Verplqn!. FLRC8B...v3.30) �}i�fYBC r}�6SIitQI�tl71i��.}!,Qtl��a;%IIt[nOIC��i><s,�StS Y. z .z, f sr � 1. y, � r j=.t'It$�Ptt4Yali%�eY0tO417x{BilEr�lil`". ���+`♦yC,t�5�,tlyt19��1{{FC�yy CE'inC.� - 9c P s _z.,gx ; k � �.�.p^�M'�u 7 � �3 ,�s? ' v,s crc' a;£^ s r Fn "'�hC-'i�ilrl9y i11�Cd��': :Vt4p[l,*}-:��y��W�:6'6<'5, ....,�:,... ,"x.�..,, .SS,..�AS Y's.T.'^>F✓...;..�.c...:..f.y`". ....�.�--. w. ..�... �f,. �.S,:. �........:.�,..,�,'..,.... „�.., �a �".. ,,.. 7..�.= System 1 Room Load Summary »:. .aJ.o.';:<,���♦`.`r,hu :Q',t:>'�X;u�>:aT`:.�\:: <.`'♦♦ "n;va:�2<ra; �a.,,am, ♦ "::d$aa.>¢. 7>a> ...w.,v,,:..p.}�, »a,a, r �<,,.$.. .i\a::,,a . ,.\..: >.:>x ..,. .:a\�t:Y.:. "AA:`.:, ,.. �� .,. ... "ag�:a o>.reK. .,....,.: 3:.. ... .... :.a �.:>... .,... a:,.e>.`.i:3;:z.,�>....:., :5...,... ..: ,:.::. �,:.: ...._.::....::...�.2♦♦ `:..a..;..,..,.. :.b'p�`>::a$..>`:.:�i`:axn:.... as n..>:g .. >\,...». .ox;. .a.».a \. .„.. va�u, ♦u. ,.«. .":,.a...<. ,.,@..o. c¢:j'>».:a,;;<.>:,>'+.ax¢., y'iti:, a:. >. . ,\... .'.�� a.a .x♦.a......�\�::., .. .:. ♦.`._. .. .:?c..�... .♦oY.aci<.•asx�t r.,:.a. x:.w.� .'hp.>izs , .., N��a....}� ..� 6 ♦♦a .. , a_.»..,<. mac. '.,a .:: ::. t,x . :...�.:.�;;?>; > . c::�:4' RR�� i. �adi.Q... .'.<D. ♦ ,..>:"♦u... "v. .. i4„C`4. \ .$,.'f.<:UAw>:..,?�ti..a...M\':SNrim;`>i:,.>>vC•;:.. ':X.......:.<:.»>: a,� a.. '..v, Y. a.. .,° ..� .♦y♦». .. .... .,... ,.D., W;.Wraa'.`♦...,....!...aR,,.. a3.,C... .. .. ..... .. .... n♦........ ._.. ..,.... Yx>,,... <.... .. \�' ...;..<.>:.c:: ate♦ \...<::...f'j\:\:'Z.. ..a.. r,. xx..... ...♦,.a,�...:.; a. .:..:..,.a, .��.�U. ..4.:a g�,.a:.a. ♦V'.c',.�iu.... «aF:Sa >..♦�` . � ` t�> �"z s'o. , a`'3�.:•,"7::.,...rcnz";ix. ♦� .a , `eTI:NG.C.�\' 'i'i♦, `^» c �`aa::�:a`�\�`'`�1:1 >�<`CL x%a<w. .4�� N x �$ �'♦ � \ < ,2�,.y .. .. \ �i5 a> . ai, \.,.. `a>a♦,. �x<, ;. J�a�FtYt3::;i�.+',.> +.♦wa:^<a. ..: .a'<..e : <. R:.iiFcJ�#Y:.. ...:�il'IYt� =Zone 1- 1 Foyer 95 3,620 47 1-5 579 1,736 368 79 79 2 KitBrk 257 7,708 100 2-5 569 3,413 1,798 155 155 3 Liv/Din 336 10,453 136 2-6 545 4,705 757 214 214 4 MstrBth/WIC 420 12,743 166 3-6 508 6,572 2,368 299 299 5 Land/Hall 184 5,086 66 1-5 627 1,878 668 85 85 6 Bdrm #3 176 5,510 72 2-4 693 2,659 1,033 121 121 7 Bdrm #2/Bth 216 9,752 127 2-6 567 4,890 2,207 222 222 System 1 total 1,684 54,872 713 25,853 9,199 1,176 1,176 System 1 Main Trunk Size: 16 in. Velocity: 842 ft./min Loss per 100 ft.: 0.087 in.wg a9 ♦i,\ic.,<c ~;. '4.. x♦a. a,.<:^♦"'a, ., �:::w,:a>»ti.:H.i.Aaa.;.a,»<aa...::>;��.;1>..x..:..:..is<..5!>s<:.:t�:Y:1yiL. ..: h.:a<>.<.. ..;.m. t.' .._... '.. .... ..>. ..'..: .. ....:�»>a{U�»♦a.♦�...`...�..♦....aa,.3..aaa..>:.iY:;.'.w:'a<>a<3.x<.:�.o>.�i,C:.1a:«.:<.,:<«<M;:aa:;<;;'>.3°>.e.x.t;'>,,. s<A,.y,v♦n,.,a«,».:?,<aa>..»kx:i>i..>....:<o:<.;rii:.<.:: ��Z z'p�i♦'ia��i` c��,n�,w���\���.;C �¢\�>�,'��'�iS„�„�.;�� ,3{yi��,\�u,,W » @k�l�'�l��c\,��SW\�r ' �S�r hak 4u x8 �'.� :. , �x .' o`x �.v\ a��c ea >.a..X�.t.^fSi�a< >'te.e�°.a`',`ox.. C.. n:a, u'ft> ♦�°�^�tl .a o<T� » Y i .ri. � ��U1` x \. ec�� �. '.•,��\, \ \U\'�.c�. aa�'\',♦� C � yy� .`.S,.aY.o:.. b>k"s' �y }� ai.: }�yy,� .a,...`.' ... �;.,..: ,.... ♦♦ � . �\C.:�.�. .:uk\::�ft,$'�i{3.i?ix '....:''°.'E��s1�°. `♦�v,. c...pa'Y4F7. kS1�:: ..Vd♦<:.`�:x.v�i�<,:A��...a;,,a:,..0>v: �yi�c ,\b, v'.;:..: :'cw, .,..._E>v,xc.. .. ..,. .a.;wexe&g,x<'.,>�>:..>.,. :&\..:;;'?:<>,):e ><.xC::a.:. Net Required: 2.92 74% / 26% 25,853 _9,199 35,052 ♦yam .a � Maw — Heating SystemM Cooling System ' Type: Model: .Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh ».:...,..,..�..�.,...�..,..n..::n..,..:^..n:.,:9.:.::.................................... ...:..,w....:,........,.::....:n:..........,,.,..,......... :Iris ` ^U Detailed Room Loads - Room 7 - Bdrm #2/Bth (Peak Method) .. L. ,. ,v? »:C':a�i:(v: .. v';C:,v,Y/•.:,C:iii>u>a.>:>').:.iv>: ' . `iS:`. � 2L`. :ne � w.r "��`� .12..:. 00%••`o3t�'? ovx.2 .....o..e.2.> Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 216.0 sq.ft. Supply Air: 222 CFM Ceiling Height: 9.4 ft. Supply Air Changes: 6.6 AC/hr Volume: 2,030.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air. 111 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 567 . Umin. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 41 CFM Actual Loss: 0.205 .1n.wg./100 ft. Actual Summer Infil.: 23 CFM :o.'... .. �Z .. >»a.?'.:\:..�..-....?s�.:a\>. �+......, . a <...._:. ..�?<Fii.�i:. :r�'Y... �:z•:, '�.�»o:;::o.: .�<�i��..� �E� v a �a+n.„:. ;?�`.">C�� 'V.�T.a.;ta'::9?<>•:.:a<.'..:. ' :� �»�...<:'�:+��a.:u..n.:.a W-Wall-14E�-8c27X9.4 ...Af3. a.. .. ..,, . 253.8 0.192 4.6 1,157 2.4 �. `�• �` 0 610 S -Wall-I4E-4-8c 13 X 9.4 74.2 0.152 4.6 338 0.8 -0 62 E -Wall-I4E-4-8c 6 X 9.4 22.4 0.152 4.6 102 1.0 ' ' 0. - . 23 N -Wall-12B-0bw 9 X 9.4 84.6 0.097 2.9 246 0.9 0 S .GIs-IA-rb-d shgc-0.35 100%S 48 1.080 32.4 1,556 27.2 0 1,304 ' (2) E-Gls-1A-rb-dshgo-0.35I00%S 34 1.080 32.4 1,102 27.2 0. 924 (2) UP-Roof-18B-19 18 X 12 216 0.051 1.5 330 1.1 0 231 FJoor-22A-pm 55 ft..Per. 55 1.180 35.4 1,947 0.0 0 0 Subtotals for Structure: 6,778 0 3,229 Infil.: Win.:40.9, Sum.:23.4 517 2.609 1,349 0.747 971 386 Ductwork: 0.200 1,625 0.200 86 815 People: 200 lat/per, 230 sen/per: 2 400. 460 Equipment: 750 0 Room Totals: 9,752 2,207 4,890 � �. �'8off5xazs+��{.e�uetoty(ntrllrc. yi2�e/sls�iYa_a.�Cal&3�gEifi�emmerc6at�iSiA4.Laads :i~scnaiizetl 8erviceJn� F . v: G . .f11G� {11��� Detailed Room Loads - Room 6 - Bdrm #3 (Peak Method) ,>.. n. ♦.a r .5.. .a1._\ *:o. :o.�%�,.,>:.x».._..... .. p b::.•.::.)\: .. n.ji°<:::>..:2'. w:v:2r::..2 .:.... n. :<.'..w. '.:o'j>•; v:.yf<.<.4> a. n.. ..........::_J._C.�`.\.......:d..am\`k: n,.\D:�i>'`i:..\� \'A�:':tkn<a.$e..'., a.9`.il4,�e.....N�.`.^.•>S'...,..h\.:..':::a:a.O,a',r(_'>,a:`j�`�2E:.S ��.Yt.Ya.:'S:Q2»4R::..:..::.Sri::>o)1a.. y.y <..:L y.Q:..>.. n.:,.::.: Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 13.5 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 176.0 sq.ft. Supply Air: 121 CFM Ceiling Height: 9.4 ft. Supply Air Changes: 4.4 AC/hr Volume: 1,650.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 60 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 693 ftJmin. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 23 CFM Actual Loss: 0.539 in.wgJ100 ft. Actual Summer Infil.: 13 CFM .... _o.«:?Si:•• � . ,... '\ .`.Y.: .c. taw. .,.:: o., :xi a. .. .. .:> `,.. �::..a s..... .. .... .. ... a..aa. b.. aaan.:.�:.. .. .. ... .n.«v,:>oe. v..:,. .:. ..: ;. t.:;;:•:;,.:a \ `2 (yy�� ::�.4�.y:....>. .... ...... a:... ... ...>:..... ..a .a.a...a.:.an .... , r. .. .......... .... ...... ...v�.4.a....k..5. :'H`�' a?:a:.. «a: E -Wall-14E-4-8c 18 X 9.4 169.2 0.152 4.6 772 1.0 0 175 S -Wall-14E-4-8c 13 X 9.4 81.4 0.152 4.6 371 0.8 0 68 S-GIs-1A-rb-dshge-0.35100%S 40.8 1.080 32.4 1,322 27.2 0 1,108, (2) UP-Roof-1 8B-1 9 13.5 X 13 175.5 0.051 1.5 269 1-1 0 188 Floor-22A-pm 31 ft..Per. 31 1.180 35.4 1,097 '0.0 0 0 Subtotals for Structure: 3,831 0 1,539 Infil.: Win.: 23.1, Sum 13.2 291 2.612 761 V45 ,,%. -547 • 217 Ductwork: 0.200 918 02-00 ` ": 86 443 People: 200.lat/per, 230 sen/per: 2 400 460 Room Totals 5,510 1';033 2,659 Detailed Room Loads - Room 5 - Land/Hall (Peak Method) Room Length: 16.0 ft. System Number: 1 R6om Width: 11.5 ft. Zone Number: 1 Area: 184.0 sq.ft. Supply Air. 85 CFM Ceiling Height: 9.4 ft. Supply Air Changes: 3.0 AC/hr Volume: 1,730.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air. 85 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 627 Unnin. Percent of Supply: 0 % Design Loss: 0.100 in.wgJ100 ft. Actual Winter Infil.: 25 CFM Actual Loss: 0.322 in.wgJ100 ft. Actual Summer Infil.: 14 CFM W -Wall-14E-4-8c 10 X 9.4 94 0.152 4.6 429 2.4 0 226 N -Wall-I28-Obw 6 X 9.4 39.4 0.097 2.9 115 0.9 0_ 35 N -Wall-I4E-4-8c 6 X 9.4 - 20.4 0.152 4.6 93 " . 1.4 0 28 N -Door-I,1 D 2.5 X 6.8 . 17 0.390 11.7 199 10.1 0 172 N -Door-11 D 3 X'8 24 0.390 11.7 281 10.1 0 243 N -GIs-IA-rb•o shgc-0.35 1000/o$ 12 1.080 32.4 389 27.2 0 326 LIP-Roof-1813219 16 X 11:5 '- ... 184 0.051 1.5 282 1.1 0 Q 97 Floor-22A-pm 332.:Per. 33 1.180 35.4 1,168 0.0 0 = 0 Subtotals for Structure: ' 3,428 0. 1,334 Infil.: Wiri:: 24.6, Sum:: 14.0 310 2.611 810 0.745 582 231 Ductwork: 0.200 848 0.200 86 " 313 Room Totals: 5,086 668 1,878 Detailed Room Loads - Room 4Mrl I kMod Room Length: 35.0 ft. System Number. 1 Room Width: 12.0 ft. Zone Number: 1 Area: 420.0 sq.ft. Supply Air: 299 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 4.3 AC/hr Volume: 4,200.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 100 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 508 ftJmin. Percent of Supply: 0 % Design Loss: 0.100 in.wgJ100 ft. Actual Winter Infil.: 37 CFM Actual Loss: 0.165 in.wgJ100 ft. Actual Summer Infil.: 21 CFM s-VVau-14t-4-6c 12 X 10 57 0.152 4.6 260 0.8 0 48 S`-GIs-IA-rb-o shgc-0.35 100%S 15 1.080 32.4 486 27.1 0 407 $-GIs-IA-rb-dshgc-0.35100%S 48 1.080 32.4 1,556 27.2 0 1,304 (2) UP-Roof=1813-19 35'X 12 420 0.051 1.5 643 . 1,1 0 450 Floor-20P=0c 12 X.35 420 0.385 11.6 4,851 3.9 0 1 617 SubtotalsforStructure: 9,392 0_ ; 4,667. Infil.: Win.: 37.2, Sum.: 21.3 470 2.611 1,227 0.745 882 350 Ductwork: 0.200 2,124 0.200 ' 86 1,095 People: 200 IaUper, 230 sen/per: 2 400 46b Equipment: .. 1000 p Room Totals: 12,743 2,368• 6,572 Detailed Room Loads - Room 3 - LivlDin (Peak Method) M. Calculation Mode: Htg. & c1g. Occurrences: Room Length: 24.0 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 1 Area: 336.0 sq.ft. Supply Air: 214. CFM Ceiling Height: 9.4 ft. Supply Air Changes: 4.1 AC/hr Volume: 3,158.0 cuft Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent., 0 CFM Runout Air: 107 CFM Percent of Supply.:'0z % Runout Duct Size: 6 in. Actual Summer Vent.: "0- CFM RunoptAir Velocity: 545 Umin. Percent of Supply: 0, Design Loss: 0.100 in.wgJl 00 ft. Actual Winter Infil.: n.um .Actual Loss: 0.190 in.wgJl 00 ft. Actual Summer Infil.: 16-CFM �11-1 P-W 8 E. a 4E 1.0 0 233 _Wall-Wall-4_8 0.8 0 57 -Gls-1 A-rb-o shgc-0.35 1 00%S 15 1.080 32.4 486 27.1 0 407 S -GIs-lA-rb-d shgc-0.35 1 00%S 48 1.080 32.4 1,556 27.2 0 1,304 (2) UP-Roof-1 8B-1 9 24 X 14 336 0.061 1.5 514 1.1 0 360 Floor-20P-Oc 14 X 24 336 0.385 11.6 3,881 3.9 0 1,294 Subtotals for Structure: 7,779 0 3,655 Infil.: Win.: 28.3, Sum.: 16.2 357 2.609 932 0.745 671 266 Ductwork: 0.200 1,742 0.200 86 784 Room Totals: 10,453 757 4,705 ,... ua�>ki�l�k.;(figd�p�at{talyle4.fgEri;�.mmareE#tiA�Gaa�s __ �, sSc4ftsvaz�l3e �(1e�.R�(.,/I.r{icq ���{,,,�{,,�i1 Vii�lllLT t�"+4wSe%3 Y'v.L`SR�>� 9,.� L�..... -/K" '1"•M - / a' .-� L A /_ �iirrE�IRIWCt'1i. yMe1�1C1V`oF1 Detailed Room Loads - Room 2 - KitBrk (Peak Method) ��><a��.-�:\, >?L .v LL.v .y>>:aO..NiiL �;;>"kx:K:«6vaU:<i;ka::;`.k;s::p>O,'::: �Sh•:..:....,. ♦v �..� :`>v:eSJi`L`::: >.'e��>... .. C.'i:�•>`.:\kx..v�:�S":ai..i.. . R6::pvv.LnJ�..:>oMC>ifi:`\,L'...... v .v�},.v3. v. ..,.vY..wnft'.: v..v.k:? ;.W.yye^>p..:.v{:: Y)..:'$:k�: :.. .. ....:........:. :..........:....ea<.>« :.......,. Ck``�n�:a�:.,.....,.4..__Cf:._....... .an..v v.A;::iS.,. ... .;xxa.;:a:..:a,.'n>u.:rt. _v.�.. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 19.0- ft. System Number. 1 Room Width: 13.5 ft. Zone Number: 1 Area: 257.0 sq.ft. Supply Air: 155 CFM Ceiling Height: 9.4 ft. Supply Air Changes: 3.9 AClhr Volume: 2,411.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM ..; Runout Air:. 78 CFM Percent of Supply.: 0 % , Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM- Runout Air Velocity: 569 Umin. Percent of Supply: 10 Design Loss: 0.100 in.wgJ100 ft. Actual Winter Infil.: 22 CFM Actual Loss: 0.267 in.wgJ100 ft. Actual Summer Infil.: 12 CFM .\ . `: 3:'�`, :i?+tix: SaS'\�'L::a^nu:'t ': ,`."Txw.a'.�'• ..\. .. ,\ a :A`i\.>.a?.,'... ... . . .:... x. ,. , O aA ... .. :' \'ctiS>iC:xa\w Yik?•-. 3� \ .. ...8..'«::k�ao`ae;`v"a.:'��,. U...i.:..j:•rkcn:.. w2.:c>:.'o...'«\`'C.ao:�:«.a4.:.��z ` a �:> � \`\>: �' " ;`..¢`;:�SaE.:,4�.':<. .' i ':?..�::.:;.:axk�?�YonE♦4�Yeu.:ax.:ax:....:.�h»:ok«kx..<.>:'�.+"(.�I:x`n�``::':.>„>.;<; din T:::�`�:">5:>�$w.::`'cbi;`.:c.:C:¢-::Sti?Y.:, •:�aa\. o. `:',"o.:::!:?2�f.. . �...:,<k?.. a......�IF. .. .:ox«..u,:.x�rt- FE,aa N -Wall-14E-4-8c 20 X 9.4 148 0.152 4.6 675 ... 1.4 0 205 E -Wall-14E-4-8c 9 X 9.4 84.6 0.152 4.6 386 1.0 0 87 N-GIs-1A-rb-oshgc-0.35100%S 40 1.080 32.4 1,296 27.2 0 1,086 (2) UP-Roof-I813-19 19 X 13.5 256.5 0.051 1.5 392 1.1 0 275 Floor-20P-Oc 13.5 X 19 256.5 0.385 11.6 2,963 3.9 0 988 Subtotals for Structure: 5,712 0 2,641 Infil.: Win.: 21.6, Sum.: 12.3 273 2.608 711 0.745 512 203 Ductwork: 0.200 1,285 0.200 86 569 Equipment: 1200 0 Room Totals: 7,708 1,798 3,413 Detailed Room Loads - Room 1 - Foyer (Peak Method) Room Length: 10.0 ft. System Number 1 Room Width: 9.5' ft. -Zone Number: 1 Area: 95.0 sq.ft Supply Air:_ 79 CFM Ceiling Height: 9.4 ft. Supply Air Changes: 5.3_AC/hr Volume: 893.0 cuff Required Veht.: 0 CFM Number of Registers: 1 Actual Winter Vent.: -- . 0 CFM" Runout Air: 79 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent_:: 0 CFM Runout Air velocity: 579 ftJmin. Percent of Supply: ti 016 Design Loss,. 0.100 in.wgJ100 ft. Actual Winter Infil.: : ' 12 CFM .. . Actual Loss: 0.276 in.wg./100 ft. Actual Summer Infil.: 7 • CFM N -Wall-14E-4-8c 6 X 9.4 31.4 0.152 4.6 143 1.4 0 43 N -GIs-IA-rb-o shgc-0.35 100%S 25 1.080 32.4 810 29.1 0 727 UP-Roof-I8B-19 10 X 9.5 95 0.051 1.5 145 1.1 0 102 Floor-20P-Oc 9.5 X 10 95 0.385 11.6 1,097 3.9 0 366 Subtotals for Structure: 2,624 0 1,335 Infil.: Win.: 11.9, Sum.: 6.8 150 2.613 393 0.745 282 112 Ductwork: 0.200 603 0.200 86 289 Room Totals: 3,620 368 1,736 `i8tvac xesiaeatiaT:;�iayt�Gbaue�eeciai[1�7Ak�L•::<.,.:,�w �. > i . psi+it�izars:Ttevekzprvec�;lifa;: ;t$ersar�ii�5ez�ee7no .�'a�,�:z•;:J��%ti?'„;n Nw=¢r r ° a'r /sue z� cac<� sr ? _ �' r ss ? '�'IYE'�431K8yiY�OfrE�siis. 'E• CL. F t A`"N O.w...;>V YLwG.� .> k 0,..........:... F / System 9, Zone 1 Summary Loads (Peak Method) \k.:,:gmvi.:3b.oS.. :.J::>.:.:'�.:'._:..,,.m\a'c :.. ..,...v. ,a`.'oays°u3:>. �::•£»J::v SC< ) i>:4:::ij¢:�p:<¢..: . ..' ..n�. .. : no . .. .. 3A�\ �, v, ,. ,.. ,.;`Jt .\.?\ a,...:4� .. ... a:.¢,\a3:<¢:?•:i i?:<¢:a>h:,..<?`.:n,., ., �n 3x'Syr.::..a:....�n'�.4^.;A..:Bi»:>s<.,. ... .: ::.. a. �;�tcR< .\¢F..o.,„\io:....;...,.>....;¢;.•G..,m\....J:,\:.. x>::...>>.¢.;.�:..,J.a �. o,..\.o:.c> ,.. c?.:._, :.,.%:r. .... ...? ,< 1A-rb-o: Glazing -Single pane, operable window, reflective, 25 - 810 0 727 727 metal frame with break 1A-rb-o: Glazing -Single pane, operable window,"reflective, 82 .2;657 0- 2,226 2,226 metal frame with break, -ground reflectance'='0.32, outdoor insect screen with 50% coverage, dark color drapes with.loose weave with 25% coverage 1A-rb-d: Glazing -Single pane, sliding glass door; 21.8.8 7,092 Q_=- 5,944,, 5,944 reflective, metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, dark color drapeswith loose weave with 25% coverage 11D: Door Solid,Core 41 486 0 415� 415 14E4-8c IiVall-two courses brick, brick on concrete or 8 1878 8,565 0 2,94 2,010 inches concrete, 8 inches of 140# concrete with R-4 board insulation - 12B-Obw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, 124 361 0 110 110 no board insulation, brick finish, wood studs 18B-19: Roof/Ceiling-Below roof joists, White or Light 1683 2,575 0 1,803 1,803 Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or 'Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-19 blanket or loose fill 20P-0c: Floor -Over open crawl space or garage, Passive, 1107.5 12,792 0 4,265 4,265 no insulation, carpet or hardwood 22A-pm: Floor -Slab on grade, No edge insulation, no 119 4,212 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 39,544 0 18,400 18,400 People: 6 1,200 1,380 2,580 Equipment: 2,950 0 2,950 Lighting: 0 0 0 Ductwork: 9,145 602 4,308 4,910 Infiltration: Winter CFM: 188, Summer CFM: 107 6,183 4,447 1,765 6,212 System 1, Zone 1 Load Totals: 54,872 9,199 25,853 35,052 .. , .. ..\_.\:... ..J.c ...,.\ ram. �....:.: J.«� :.: ._. ..... .. .. ., ..� .a.a\....,. ., s.:<o;::•>.,..o. \.a, ....XnJ.,.,, a. ..:...,....`x..a..o.^k::r,.::<..;,;¢.>w.:a:es;.<±:KJ...:\,>o.::.. ..>. .. ,.\... ....... ......:.,. ..,\.<,•.,.:::.,„.\.J._:>.aa..\,..:..x...,a.yss:,.:>e:<..a.<.:.o.¢.v;;,;:��.:�...,.c..,..k;>,.rz'i:::r�.a4'f?:".<3s:>S�:F:?-:.;:e::¢..<3wJ Supply CFM: 1,176 (4.4AC/hr) CFM Per Squareft.: 0.698 Square ft. of Room Area: 1,684 Square ft. Per Ton: 577 ' • ., v .. \,:,..\Jg. 'ra <..<.a> .0.>. ......,.,. .YN. S.vn...\,,. a,".. \ :`J...0 ¢... y_ea C..,, b:........._..,_:,:ci,isy.,>:>gi?:ii:L::J::;:`.'.i:i:x:<i:Cb;;Y,e:¢>:k>:. ...... .:.,..».:. >aE'F`�i::;;:z<,:n Total Heating Required: 54,872 Btuh 54.872 MBH Total Sensible Gain: 25,853 Btuh 74 % Total Latent Gain: 9,199 Btuh 26 % Total Cooling Required: 35,052 Btuh 2.92 Tons (Based On Sensible + Latent) �n\\\�....,a�a.>.n:..xi'C•.,aa... .a v, a��,�..ye\\r<ttaoss..,... `>: \a..:.:.a\. \n"` ¢::;k<3,'\:Parza «sv,?..w!i«x..x..:>%.¢:ib.ya..;a«<.r.,.i;:?i%¢n<,.,:...>. ::...,> ...\,,.\•.a\k,.\__....a.a.,,...,.,.,_..a.a�.o:<;.,<.,i`.'..,Fo._e,.:.ro':i...,,..:....�,.`aaomoe:`:?.a\:\>a,<e«:..,..L.::>.;033::::Ca,b>a.<o..:..e.,t::..,.7::a...:...:::..:.>:>::..ara>:._::e:,..:3...:;.:;.::a;iC:' Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ..yy:+�.:ydC R,R,..S//1��t�4�c1fylaT:y�:istghCtlu[aEatHii'lttilit�l�sM>%>a?��z<_u��>�w��x'-3,;#',%%:„:>'„'.„�"'""=�z"�= ` �_k'CiRSQftWai@i7@YetpliRlBtlfrldci. 'YL�rJ�r�.Gl/ aC1 YICE 1TI% �, !'' X.' lRi�`kNS 3'�Y�' fi,�.•^"..I � : � y\�rS'f{g'<SS`"C� �>r.J . - _ t � � F E.�� -. y `bL L' F t iH'i .����,.. "^rt ^>_ c t�:tin�i?. \ y�.i. "�•R`ik �` r w c xu,3 s S r �r � r xt� • a, a, s < +tz.3. srrl ^u � ziY - ' %,zwszau Rf 3 r 9' >f > System 1 Torrey Mod. C Summary Loads (Peak Method) ;.s. \.,�:..:.¢>.a.. ...\?\ .�\. . .. `.\<«. c\,>:.a.�i\vn:. \ T ,,.. &r...,�.y.....m.>J...:?�+\�.; .i:\:. �:r:,..L. t. v:S,'�`a>>..1..if.at>`x?:u,.: A3,.,a<.. .h..:Jr•,: ,�\>,. rr. ..:, J.?...\:..>:x..,\\`»:.v`>\.�; <. �.. .uJwk`.\rJ"'+o:�,":.<. .,.��-i:...aa.?.3�,. i..�:..a. .._�:J.'".:Rav:�iiw.JCn.?. .p�S.^.��:'a��xs>...xi:t.o.Y.e':,:SD.x:.�..>:R2E.n'Yv... ,<.J.>:�>� .�..�;Ji;.,°>;.:`i:5YSR:::;v.;>:.).J...,...:�:;nv..��.:.,<'!..,:@..g..�.:i#::><gi;rx:.:o:a:a:zyv.`:_.><,a...£,.:.,.>.:.:a?.:.y..:.` � Y+�:...�..a. <>... 1A-rb-o: Glazing -Single pane, operable window, reflective, 25 810 0 727 727 'metal frame with break IA-rb-o: Glazing -Single pane, operable window, reflective, 82 2,657 0 2,226 2,226 metal frame with break, ground reflectance = 0.32, outdoor.insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage IA-rb-d: Glazing -Single pane, sliding glass door, 218.8 7,092 0 5,944 5,944 reflective; metal frame with break'ground reflectance 0,32, outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage i1D:.Door-Solid:Core 41 480 0 415 415 14E-4-8c: Wall -two courses brick, brick on concrete or 8 1878 8,565 0 2,910 2,910 inches concrete, 8 inches of 140# concrete with R-4 'b'oard',insulation .12B-0bw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, 124 361 0 110 110 no board insulation, brick finish, wood studs 18B-19: Roof/Ceiling-Below roof joists, White or Light 1683 2,575 0 1,803 1,803 Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-19 blanket or loose fill 20P-0c: Floor -Over open crawl space or garage, Passive, 1107.5 12,792 0 4,265 4,265 no insulation, carpet or hardwood 22A-pm: Floor -Slab on grade, No edge insulation, no 119 4,212 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 39,544 0 18,400 18,400 People: 6 1,200 1,380 2,580 Equipment: 2,950 0 2,950 Lighting: 0 0 0 Ductwork: 9,145 602 4,308 4,910 Infiltration: Winter CFM: 188, Summer CFM: 107 6,183 4,447 1,765 6,212 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Torrey Mod. C Load Totals: 54,872 9,199 25,853 35,052 .a77.'i .a ..J.�ia \.�.::. siiJ[l;: \:: r:>ciC S':".+":>8'bRi>erYkid.`:•.:O:S:j:.y::Cia"EiJ:.•.::...:::u :: �.tter:<J:i>z.>^.iazo:vJ>.r: ...�.�..........�.Jrx;..:>'�,:�Rsr...:.:�:.:w:r..,b.,.C.,.,x:<:�.?,...x<. ..•.�3...\,>._:>bme..�.,:...a>:r:.F's:\;>:•J..:,.:...:.\�i.J»...;;:...;.\.a.J>.,a«a.:J.r..h....,>:,<:aad::::;ssez:.:z<s::a:'£;Sstst::S::;:Rz: Supply CFM: 1,176 (4.4 AC/hr) CFM Per Square ft.: 0.698 Square ft. of Room Area: 1,684 Square R Per Ton: 577 :�>.:120Kcx:..._ v .J.,,, a� . Jngz�,im,:.<x:">rs:.ite:>.a:.:!Q<:�..�a>., J...v..:..:....:<.,.. :�:.��.'.'xi�Y� heRc➢t `E:r.»,>:ca\,r�..�i.�«.:� .e..a'^i.Jr>s.iJ;>�Yo.:r..f;:`air:«: Jye .. Total Heating Required With Outside Air: 54,872 Btuh 54.872 MBH Total Sensible Gain: 25,853 Btuh 74 % Total Latent Gain: 9,199 Btuh 26 % Total Cooling Required With Outside Air: 35,052 Btuh 2.92 Tons (Based On Sensible + Latent) ...\\ :\v\\�>�...^aa"ua.`... >w�:��:a:;RanaR,,,is•>:�:�ar<:>:r>�«`si�\:::>::;:�,r..,,.:a::�si:,,:;.,.:„,� " a.<;....r.Jv\J>..,:: \;>:J::�.xq;.3,.,:\ a.,....: .: �a...\:v\,.R:.ve:«.3x: .,:F <:•wSc"a.,..J:J..>x<:c.:..>uiyi.,',°`e':��: Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meats both sensible and latent loads. Rhvaa iiuslderRial £ltghtornlneecBaiEilrltCtaads'r Etitx9atbvatei3aveiapme ,I �CLaOftat�tetlSeMceln�E � � x? LsH.a �D';��s x�xyh&�3s � :sY,F \� s � -- f°s hss-r rrs _'� ssi>FSrfUyRil3f1E{£r' :%iil$eTi �Y..:� .. .s:.....,.,..t�sa. Hx H..:,F':.- -;: ,,..a..:......,..L �' .., ..0......:... :.:..: µ•K., H; :,. .... ,:c ,-S ''::..,..� ',r::..::, .:. ,:: <,:,.,.. Total Building Summary Loads :�... .. .... _::o .. a......,.; .; .:..t»x:,a. ::sn.:os., o._.. .. ._._:.>:.<.::c.'r3`: a... v.>c;c.;•>.:p. �.. , i.:.. >s7):>::nn::.;'�' non,.\tw . �� ..>,;.Da,,.,u .,x.. .:...,.:.'\:e¢•.> x...,�bx: wro:<....,. .aF\... rik �a;�.�.... � •i:. \.>.:ot;,ax.::i:'s:�S?. c T .. ...•g'!EC. \.. . b',a ..\ .\tZ. .., .....\,. 3 . .,Z,a `v\.x �„Y. .a, sox..SA�.,,3'LXRY.,c.. , c��rii �?a`{<Yt. .a:.:S;..: 1.•.cto«k:<.:a:.„.:;a.\.. ..:_>.,..::�\o\..a yv ,.,,, \.,Lo m:\ .,a>.. ...�.. .J<: �._a r•.'S;L ' .,..., . < ..�` :> ..:.� ::.\:..x,. ,t ,.o ..\ ce, :.a..aa:Laa• \ ,\\. \k'o.¢..\,..e:.. >s?. < .: >\'. �+ : :S::ah.,... x:::.:_,....::.: 'ti>.o:X<> ... :\e;.:;aa•:a..,:,y.,;m.. . v«J:�.a..: •o....v'ktY. ...vvv:<a,...< .ao.o .:. .. ,:a.�xto: \;<\sa;. y« :.. ' ;�;�\<L:w u;3\^3;`�"aY:' 'ea.�:;.a.,. ' , ..,\`•... `.t ,.. .. ... ..,.�A.. ..... Qltart:,. �:,. i..ti�J.%'.'S,..,.»ss::'��I.'ok............:..�`.j'fi�r�a5�,:«a.. :..:.o.�i'. �i; 1A-rb-o: Glazing -Single pane, operable window, reflective, 25 810 0 727 727 metal frame with break 1A-rb-o: Glazing -Single pane, operable window, reflective, 82 2,657 0 2,226 2,226 metal frame with break, ground reflectance = 0.32, outdoor insect screen with 50% coverage, dark color drapes with loose weave with 25% coverage 1A-rb-d: Glazing -Single pane; sliding glass door, 218.8 7,092 0 5,944 5,944 reflective,. metal frame with break, ground reflectance = 0.32, outdoor insect:screen with 50% coverage, dark color drapes with loose weave with 25% coverage 11 D: Door -Solid Core 41 480 0 415 415 14E-4-8c: Wall -two coursesbrick, brick on concrete or 8 1878 8,555 0 2,910 2,910 inches.concrete, 8 inches of 140# concrete with R-4 board it suietion 12B-Obw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, 124 361 0 110 110 no board insulation, brick finish, wood studs 18B-19: Roof/Ceiling-Below.roof joists, White or Light 1683 2,575 0 1,803 1,803 Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-19 blanket or loose fill 20P-0c: Floor -Over open crawl space or garage, Passive, 1107.5 12,792 0 4,265 4,265 no insulation, carpet or hardwood 22A-pm: Floor -Slab on grade, No edge insulation, no 119 4,212 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 39,544 0 18,400 18,400 People: 6 1,200 1,380 2,580 Equipment: 2,950 0 2,950 Lighting: 0 0 0 Ductwork: 9,145 602 4,308 4,910 Infiltration: Winter CFM: 188, Summer CFM: 107 6,183 4,447 1,765 6,212 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 54,872 9,199 25,853 35,052 •vi!.Y.1W,v,.��b.'�R. ...�R\Wool �, \x. Z...,ov? Total Building Supply CFM: \�ai,'..Pa.u,.:a...x::,a-\:,`::<ay,.:..3.•..:a.:ka�:'..�,..:.s. ..,.s::�:Y,..,..s..:,...o._:.,3..::)k.,<.a-,::-�.s.<2<•`�..«.,,::<A.rac.:::;k.:::,oe�:. ;:):ui.s..::,p:k.:«o.p>.x.:...:�y:,.^..:.3:..,. p,.:«>.>rc.. : 1,115 (4.4 AC/hr) CFM Per Square ft.: 0.698 Square ft. of Room Area: 1,684 Square ft Per Ton: 577 , .,... a•: ...:.. ,, ,�s .. .Lsvv�>`vaa>kr,>•.. t«..v\,:..k..,>,,..k:.,:-s:<omx,....:..,:,�.,..e,..,v...,:.:.........,....._.:.,xzo,>,,.;;:;:..>.:.:........ ......v is tYkkeaa, �,>;.. ..X1\@y,. vus. M`�:,y'xi,.k• . �\.o.:... .,.a,. ,..� vx<k.a...:: , :a'-k k:<„.. ,. x.»?e::::;:Ll:sa.::>s:..>::L:k:: Total Heating Required With Outside Air: 54,872 Btuh 54.872 MBH Total Sensible Gain: 25,853 Btuh 74 % Total Latent Gain: 9,199 Btuh 26 % Total Cooling Required With Outside Air: 35,052 Btuh 2.92 Tons (Based On Sensible + Latent) �\\\..:..\v::Y?k; .. _ya.� ....,:.. a.a` t<n•k �^v'>>';S; u>.o . ....AU. ...\ ",:cam..», L,.. .. ....x::k.::: -: .'..e^Ti. nx\.•.,vv:.`�;a+.\a.`. ...,v ,:..a>•,.\,�'a ....ay."x.....n.v..rvg:. ,.Yaoa,.a ..xr.a,,.L„ Q;....., D;C.. .ok*,1', ...o.,k.;i:<o.:^`^''G:Co.x .k., ....,......:..,. .au, ..2a�\.»., L\�co.,aaa.::..:,,..�.:a...3`i..•..o...�.aax..a..;.a.� .r._..x.. :.>�>.:>e!:k::>..:ys3::oZtc.. ..o:..r_:.<a^.xr�>,:<."c:;.>..::�..5.;.<ak,:...:<. Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 0 V mfl�.�WN N 0 CLEM0 m .� a q.a CD > V'O(ND1 (o OD 0) D�NYW A'O. O',V O A N A N-+:%O AW N OD G) OD.0 V A V OD co DIV V 0- wm owwlNj t W m W N- . N + O "O OD wowommomw V WOOD V OD CO CD W V W N), OD N ul sn O 0) (A fO pAp�� IV>0 V N O N> A N > > W DiNNO V pWp� N� OD p.cn VON N O OD W W OD O > > > > V N V OI 01 W O A> V N O O O O V W > NNOD (O-+N V V` N-•OO)ANfo OC N NOD to>DN V V N -+ N to A V7 co O C Miscellaneous Report Summer: Calculate:. Yes Use Schedule: Yes Roughness Factor: 0.00300 Pressure Drop: 0.1000 in.wg.M00 ft. Minimum Velocity: 650 ftJmin Mabmum Velocity: 900 ftJmin Minimum Height:..,'-_-, 0 in. Mabmum.Height:. ,- _ _' ".0 Infiltration:::,. Volumeof Conditioned Space: Total Building Infiltration: Total Building Ventilation: 42 0 90 78 Yes Yes 0.01000 0.1000 in.wgJ100 ft. 450 ftJmin 750 ftJmin 0 in. 0 in. 30 72 50 75 0.700 AC/hr 0.400 AC/hr X 16072 Cu.ft. X 16072 Cu.ft. 11;250 Cu.ftJhr 6,429 Cuft/hr X 0.0167 X 0.0167 188 CFM 107 CFM 0 CFM 0 CFM —System 1— Jnfiltration & Ventilation Sensible Gain Multiplier. 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier. 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) v - 61.09 'Y it��ri:'�..';1{4i.1G.OGNwY.31aY1:(:�.y.:�.�Il.�.�........�..�:.�..��{:�:�y�.(�.-].yi`.....:...,.ubiA;v.:.;5.u',::.w::.'Y'i;£":�<�:obi::.^```:f^..G:::'::G.'<::ii':%:�:�'j..:w>.:�iG:�•^..::(A:y�:Jjt::3f ��y...� �fy� �{ .>. �PiN,V3I.T{"N4[�L9:1}M4 < { l at�QW}YAN��i/iF��tl[i�nri �.:3�.iV<: ss,£amY�.z :•.: .>: .,�:<; .... »:�:.:,,.. :tea ,.. u........x.axa - stt amr � a :d ra- -- Y'd: /.:w,. ,,.. ,:H.., ,,�:... Project Report .00&.. . 3 `g..�ar.:ca>i`: rx {4><:'`5::'. v, , .:. $?2:ec�i•<::::§;:g�:y: o.. o>s::?y,+::$;a' S:¢: a?<:.<.y;: �:"?ia s�iS�+,n�s:��..;>...•.��xtia:::.. �� File ..., .. .�x u;r4.i+n:.�?;a.�;,xt;.s\�`«a Project Filename: C-. E1iteU2hvaanAProjectslTorreyC.rhv_ Project Titie: The Torrey Madel C Koject Date: Wednesday, June 04, 2003 Client Name: Kolter Signature Homes, Inc. Client Address: 2160 NW Reserve Park Trace Ciient.City: Port St. -Lucie, FI 34986 Client Phone: 772-468-4703 Company Name: ' Nisair Air Conditioning Company'Representative Jose Compa6yAddress: 1501 Decker Ave,=D404 "Company'Clhr Stuart; FI 34994 '.Company Phone:- 7-72-283-0904- Reference.City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altdude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 0 72 0 'Summer: 90 78 50 75 61 .�r,: .. .. ,.\`...:,.,-:.. x:f.�.".;.:oxe• .... ., _..:.: ».m`3'xaa.:,>,...>.,: .4 ..:,E:.. .. e»,:«ao>::.<.a. .:.::;zA, ..,�;;...,..aq:y„.,:a.o&.`.e.c:>\<'..'`sn^`���::�'w�«k'¢.:::h>`SRki.4.��:L..<.xa.::.,tt..:.:..;e>. Total Building Supply CFM: 1,176 4.4 AC/hr CFM Per S uare It.: 0.698 Square ft. of Room Area: 1,684 Square ft. Per Ton: 577 < .,,.. a:,a.>..u.,;. :y.:�.. a,,,. ..a.>;>?<,>» 4. .. •`xx;>:o:;»:os. ..>.<3:et»..� Total Heating Required With Outside Air: 54,872 Btuh 54.872 MBH Total Sensible Gain: 25,853 Btuh 74 % Total Latent Gain: 9,199 Btuh 26 % Total Cooling Required With Outside Air. 35,052 Btuh 2.92 Tons (Based On Sensible + Latent) :. ,\...xaw,...4 ...::. ♦. ...a:. ...,:«.:,.{;>;,,:..>;4,•aaa>�rtt<e,4r>...r:.w:,..�:' .a:«::»«<.>x•4:<x«.;.»xo:�.»»a _;:.>w.>.... „1.�{11,1VY,,,:Y\\`aJ.'.>.a, a..\♦ .M>»T U..x..1.,\`>.ax.\. .4R.v.>�>axfii.?. `i'.. .. n\ ,,..Oao:, v.>..:.4.\1.C.iv",[m.:R.n.a.n. .v a4tl ...P....>if4<:<> _.•s..,a \4. .\. C M» .>\....,.� a...R��.s.:"Ya. ua4 . \:.. <. ? _ aoy<R'QN:.vAa».4«e:.>'?(R:P:>:.:::x;::::i2':`.° , .9'�^^; ...,.. .a.w..... ..> a, .... v4`:.'..Jauy...J.a.::;>`:i:`•„9..:":;i::Y:¢::`:0;::.»»:.v....e.y.:d3:;::y..�.Y.....<.:>>^>:.::.4:3:^.?:Y<:«>.p(+.:^: �:;::a<.«:. Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. The I Torrey Model C HVAC Load Calculations ._ .... for . KolterSigogture Homes, Inc. _AO NW Reservd Park Trace ..,Port St. Lucie, FI 34986 Prepared By: Jose Nisair Air Conditioning 1501 Decker Ave. - D404 Stuart, FI 34994 772-283-0904 Wednesday, June 04, 2003 �1 Tested sealed.d beeertlfied;lr>this:.houses ENERGX PERK f" J�CE LEVEL. (EPL) DISPLAY CARD ESTIIVIA x ]D EiviE kGX AE iFORA CE SCOX�Zt' 44:2- The higher the^score, theimo effiGe�tti the,hpmc . KOLTER SIGNATURE HOMES. INC., ; PORT'ST.. LU.CIE, FL, I. New Construction or wdstiag 2 Siaglataznlyormuld.ramily 3. ' Nambcr of u44 i£multMualy 4. NumberofBadtnoms 5. In this a wolat caee7 :. 6• Conditioned96or' atrrr(1trj. 7. ;blase area daype''" ;'• .; y.,S.Ingla pans a Clmr-ainglgp 0.0fN b. Clear • doaW.0auo 325,8 ft- aTinafficrSUM1daglepane 0.0111 d. Th t/othet SHGC- double pane S. -floortyp a. 91efiOn{im`'da FdBe msaladoa br Raised Ww4 Stran Wall' 9. ,Wall types a:Con=te, lmhmL Fadmor b. -Coo°, Int lame, Adjacent a.Trnma, Wood. Adjwcnt d. N/A e. N/A 10. Ceiling types a Undcr Attic b. N/A a N/A 11. Dacb((.cak Frcc) a. Sup: Une. Red tinc. AM Attie b. N/A New ,: 12. Cogftsyslcme ' Mrdti (golly _ - a Central.Unh, ... g 3 b. N/A Yes _- I683 IV o. N/A Dwbla Patio _ 0.0 fit _ (3. Hcatiagayatema 0.0 ft° ,^ a EleclrioH�xt Pomp 0.0 fl' _ R-040. 114.0(p) @ : a WA R-19.0, 633.0V - 14. Hot water systoms - _ a Meel ie Resistance R-42,1645.0 A4 _ R=4.2. 566.0 W _ b. N/A R-11A, 141.0 fe _ _ a Consmatlonarodis (HR Hest tecnvcry, Solar _ DHP-Dedicmedheatpump) R-19.0, 1000.O IP _ - 15. HVAC arcdim _ (CF-Calling l6a CV -Crass venylabmy HF-Whde house fan, PT -Pro rnahla Thmmomat Sop. R-6.0, 125.0 R _ ...... MT.C•Mjwcoao cooling,- ' MyH-Multiman teeming) I cmW that fife home bag complied with the Florldai3ae U.Emiciency.CodwForEWding. Construction through the above enerV sang h;du=`wXgh w01be attstallenii(or ==ded): In this hoots before final Offimwisc, a nGw M DiVwh .Card.wfll'be completed:' Gassed on installed Code Builderstgnature Date:" 9=Zs—o 3 ib1.a� lag Address ofNew ffome:Iwluilk A4 Ct� CitYT,yjP:�SLI FL) 3y78C Cop. 36.01F uvbr• _ MS . T.50 Cap:40.0 gallons _ BF: 0.94 *NOTE., The home's estimated energy performance score is only available through: the FLARES computer program; 7hIsisgo_taBuilding EnergyRating,jfyourscoreLe80orgreater.(or.86for•:d'US•EPA/DOEFnerpOf designation), your home may qual0 for energy efficiency mortgage (EEW inceattves fyozi:obtain a Floridd•Fnergv Gauge Rating. Contact the Energy Gauge 116111ae at 321/638-j492 or see the FrteW--Gauge wb: site at wwwfimr- ucf edu for Information and a list ofcertified Raters. For information 'about Florj4eyEngWEfficiency Code For Building Construction, contact the Department ofCommrmftyAffa�pdtl $6��j4r3i0a FLPC813.V3,30) PT, _ Equipment Schedule UnfIO Y SEER IX HSPF 9-s make-Z6movx Tom 3 Cond.Unit mocL#j.2WP '-3 NH Unit Mod.-#f47-f A1-_Vj Heater Mod.#Ag:%g,�7_-.Oq Sen . s"e Coolin". 6,000 Latent Cooling SDo Total Cool BTUs ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode Island Avenue Telephone: 772-462-8306 Ft Pierce, FL 34950 FAX: 772-462-8466 ew Construction Jurisdiction: "Occupancy: Address: Contractor Contractor's Address: State:. ; ,Architect/Engineer: Building Owner: Occupancy Type: Gross sq ft: Occupant Load: Construction Type: ( )Tenant Improvement ( )Addition ( )Renovation/alterations ( )Shell Only SLC Castle Pines Bldg. 139 8131-8141 Mulligan Circle Kolter Signature Homes 2160 NW Reserve Park Trace Florida Turner Architects & Planners rt Apartments ; 12,704 F.P.B ; B-03-337 Building Dept: 23091660 Number of stories: _ 2 Phone # - 772-468-4703 City: PSL Zip Code: 34986 _Phone # 407-658-4151-- Review Date: i ` 10/8/2003 Automatic sprinklle'rs: - Net sg ft: —Based On: SBCCI Type: V unp NOTE 1. All revisions must be incompliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 7. Penetrations through rated assemblies shall be of proper UL design. 8. UL design criteria shall be submitted with the construction plans. 9. Fire Alarm Panels shall be located indoors. THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. REVISIONS REQUIRED ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED ( ) C- Model "E" floor plan (end units): Egress windows are required although not indicated for bedroom # 3. Install egress windows. Provide a revision. 2. Model "E" Electrical plan (end units): Smoke detectors are required both inside and outside of the sleeping rooms. The master bedrooms do not indicate this. Provide a revision. Reviewed by: IL — Date: 10/8/2003