HomeMy WebLinkAboutPLANSAUTO -FILL DEVICE 1/2" FRESH WATER SUPPLY LINE• FROM EX. HOSE BIBB - BY OTHERS FIELD VERIFY H.B. LOC. & 2" OVERFLOW LINE TO ON-%ITE DRAINAGE SYSTEM 17' T 16" RAISED SPA 18" BENCH - 20" BELOW W.L. (6) THERAPY JETS (2) FILTERED INLETS (1) AQUASTAR 32CDF'L - 32" CHANNEL DRAIN (316 GPM ® 3.9 FT/SEC THRII GRATE - SINGLE UNBLOCKABLE OR EQUAL) (1) LED SPA LIGHT - NICIIELESS (1) 32" WIDE SPILLWAY TILE BACKSIDE OF SPA DOWN TO DECK 81-1011 4' --f— 4'-10" . F �— IF F_ 2.5" CH 40 (2) LED LIGHT - NICHELESS 18" BENCH - 20" BELOW W.L. 1►11 IN FINAL YARD GRADES TO BE FLUSH WITH EDGE OF POOL DECK (OR POOL WHERE NO DECK IS PROVIDED) AND TO SLOPE AWAY FROM POOL/DECK AT 1':12' MAX. FOR FIRST 6' FROM EDGE. 9'1,9' PERIMETER BONDING 7' WIRE @ 18"MIN. - 24" MAX. FROM W.L. (SEE DETAIL) C7>--3" SC It 4 —--— — — 2" SCII 40 T— SUNSIFELF 2" PVC UMBRELLA SLEEVE CUT FLUSH WITH SUN SHELF T-3rr (4) INLETS 29'-9" 11 6'-4" Ilk 16'-2" ---i- -----. --- 3'"6r1 I FOOTING FOR SCREEN ENCLOSURE, SCREEN ENCLOSURE BY OTHERS I . I 8' I . DECK-O-DRAIN I I I I I I 26r_6rr I� I 118'-6" I I I, 2' —� 12" I — — — — -'�- 2^ sCll ao 1.5 SCH 41) I _� 5'-4". 18r8rr I — -- 6- -----� 1)v . 301 — POOL/SPA EQUIP. SEE SITE PLAN: BY OTHERS REINFORCED OR PRODUCT APPROVED CONCRETE SLAB(S) (FIELD VERIFY SIZE & LOCATION) IANDHOLDS REQUIRED @ 48" MAX. SPACING - SEE DETAIL 2" STATIC LINE TO AUTO -FILL DEVICE W/APPR. COVER �AQUASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE COMPLIANT W/ ASME/ANSI A 112.19.8 - 2017 OR EQUAL STUB -OUT FOR POOL CLEANER DECK-O-DRAIN EXIST. PORCH a A n STEPS 240 SQ. IN. MIN. TOP TREAD 12" NOTE: 5'-6" PROVIDE WINDOW AND DOOR ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER FBC SIXTH EDITION, 2017 EXIST. PORCH POOL/SPA LAYOUT & PIPING PLAN SCALE: 1/4"=1'-0" 10'-1Orr NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION EXIST. RESIDENCE NOTE: THESE PLANS ARE FOR POOL AND SPA STRUCTURES, PLUMBING, EQUIPMENT/ELECTRICAL & DECK ONLY. ALL OTHER FEATURES DESIGNED BY OTHERS. 61d,0 �41r REVIEWED F CODE COMPLIANCE ST. LUC//IE COUNTY � F E�fCOPY SGANNE BY MBAs St. Lucie Cot "@8 20 Permuting Department St, Lucie County P4 a� 6� O ,,�Y,YYYYYYYYYY ICI LL CO Oh:' COO . W 0 * 1- CL:Z O.O J• ta2.� e F '04►Jp1 11PIP i�% UM00wi rl � en00 M acn � N 9 W C C) U oo �.d �I C aPoll" wa O ,, aC00 a O N • I� I SAND SET, INTERLOCKING PAVER DECK BULLNOSE BRICK COPING SLOP DECK 9 y" PER FOOT 3" -�.I. F 4 �a^ j7L MARCITEa'- OR EQUAL .� CLEAN FILL COMPACTED TO 95% MAX. DRY DENSITY ,.y UNDER DECK ONLY 2 -03 DIA. REBAR .TOPOFBEAM -�' REINFORCING STEEL a - 03 DIA. REBAR 6" _ 12" O.C.E.W.- RADRUS ! ;- WALLS & FLOOR VARIES TYPICAL WALL SECTION 14" 18" MIN. 24" MAX. (ENTIRE PERIMETER) W.L. 48 SOLID BARE COPPER BOND I t WIREW/APPR. CLAMPS - (I (ONE ON EACH SIDE OF 1 "I I PO0L-4TOTAL) (1) 08 SOLID BARE COPPER WIRE BONDED TO POOL STEEL AS SHOWN NOTE: BONDING WIRE REQUIRED AT PERIMETER OF POOL EOUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION OF N.E.C. 2014 SEC. 690.26 4„ 6„ N "� �j' 18" 16,51r ` BELOW 10.5, SUB -GRADE - ..• 10.51, 10.5" BENCH SECTION 12". 12", 18" �r STEP SECTION 4„ SKIMMER COVER W/ MIN WRAP(2)#3 DIA. AROUND ADJUSTABLE COLLAR SKIMMER, TIED TO POOL STEEL I HEATER (GAS) - IGNITION SWITCH 2 HP AIR BLOWER MOTOR w/ BUILT-IN OVERLOAD 3 - #12 THHN CU WITHIN 112" CONDUIT SWITCH W/ 3 - #12 THEN CU WITHIN 1/2" MIN. (CONNECT TOP 20 AMP -1 POLE GFCI CONDUIT(CONNECT TOP 20 AMP - 2 POLE GFCI BREAKER) BREAKER) CONTROL/POOL PANEL W160 AMP - MANUAL MOTOR STARTER SWITCH 2 POLE BREAKER W/ INTEGRAL TIME CLOCK FOR PUMPS, MOTOR 2.7 HP PUMP MOTOR w/ BUILT-IN AND HEATER OVERLOAD SWITCH W/ 3 - #10 THHN CU WITHIN 1/2" MIN. CONDUIT (CONNECT TOP 20 AMP- 2 POLE GFCI (3) - 96 & (1) 910 GROUND BREAKER) THHNI" CU IN " RPVC CONDUIT S.P.S.T. TOGGLE SWITCH (2) LED POOL LIGHTS 12 VOLT TRANSFORMER (GET NOT REQUIRED) JUNCTION BOX (1) LED SPA LIGHT (GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S). 3. GROUND ALL BOXES, LIGHTS., MOTORS, ETC. w/ 48 SOLID, BARE COPPER 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B). 6. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS ELECTRICAL DIAGRAM N.T.S. m PIPE REDUCED TO I" 12" I---# AND RUN TO DECK BOX { 32"-,'' 33/32" AQUASTAR 32CDFL 32" 6 B - CHANNEL DRAIN (316 GPM HANDHOLD SHALL BE ACCESSIBLE WITHIN 4 FEET LEAF BASIOST Q 3.9 FT/SEC THRU GRATE•HYDROSTATIC RELIEF VALVE SINGLE UNBLOCKABLE PORT OR CAP OFF SCH 40 PVC CORD VACUUM FITTING W / NOT TO EXCEED 8 FEET AT ANY TWO POINTS ALONG THE INSIDE OF THE POOL PERIMETER'LED OR EQUAL 11/42" LIGHT SLEEVE SELF -CLOSING SAFETY COVER WHERE THE WATER DEPTH EXCEEDS 4 FEETFLOOR Itig SP WALL (HAYWARDMODEL#400 HANDHOLD DETAIL -'FITTING-OR FINISH PLASTERINSTALLED G- EQUAL INSIDE PIPE OREQUAL) POOL PUMP 25GPMMIXFLOW VACUUM LINE DETAIL MAIN DRAIN SUCTION LINE HYDROSTATIC RELIEF VALVE & TIED TOGETHER AS SHOWN PERFORATED PVC COLLECTION ABOVE - PIPE SIZE PER LED LIGHT DETAIL TUBE, WHERE REQUIRED PLAN MIN. YARD GRAVEL SUMP NOTE: 25.9 SQUARE INCH OPEN AREA, WRAPPED W/ DRAIN FEHA �j� SHIMMER DETAIL 316 GPM= 3.9 FEET PER SECOND CLOTH (RECOMMENDED) Channel Main Drain Detail SCALE: N.T.S. 2 5/8" GRADE LOT TO SLOPE AWAY FROM POOL DECK SCREEN ENCLOSURE (BY OTHERS') 12" 13RICK PAVER DECK, SAND BED uz' 12" • 12" X 12" FOOTING 12" W/(2) #5 DIA. CONT. FOOTING FOR SCREEN ENCLOSURE DOUBLE MAT OF #3 DIA. REBAR @ 12" O.C.E.W.\ IN SPA WALLS 6' 181, 1.2 16" 1 20" f � 16" W.L. n 16 DOUBLE MAT OF • y • _ 43 DIA. REBAR 12" O.C.E.W. ,;.f IN SPA WALLS COMPACTED / CLEAN FILL � : =----: •� #3 DIA. REBAR @ 6" L L y O.C.E.W. :... ;. IN SPA FLOOR =' SPA SECTION SCALE: 3/8" = P-0" 5' 30' 25' 12.5' 5' 1' SLOPE POOL SECTION TYPE 'O' POOL EQUIPMENT LAYOUT SCALE: N.T.S. 3' PUMP FRAME OR FILTER TANK MOUNT OR HEATER /ANCHOR POOL PUMP AND /FILTER PER MFGR'S. N.O.A. 4" THICK REINFORCED CONCRETE SLAB 2" MIN."„•." F.G. FILTER 4t-TI HEATER POOL PUMP, FILTER vi AND HEATER ANCHOR POINTS MAY VARY POOL EQUIPMENT ANCHORING DETAIL SEE MFGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION- EQUIPMENT SHAPES MAY VARY POOL SYSTEM FLOW RATE: 150 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC. PUMP = 2.7 HP JANDY E-PUMP - JEP2.OVS VARIABLE SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED =150 GPM @ 42 TDH 3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.511 BRANCH PIPE @ 75 GPM = 5.13 FT./SEC. (6 FT./SEC. MAX. - SUCTION LINES) 3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER =150 GPM @ 1 GPM/ SQ. FT. =150 SQ. FT. MIN. FILTER AREA LEGEND 1. 2" AIRLINE 2. 3" SPA MAIN DRAIN LINE 3. 2" VACUUM LINE 4. 3" POOL MAIN DRAIN LINE 5. 2" SKIMMER LINE 6. 3" RETURN TO JETS 7. 3" SPA RETURN LINE 8. 3" POOL RETURN LINE A. 2 HP AIR BLOWER B. 1.5" TO WASTE OR DISCHARGE TO GROUND C. 2.7 HP REC. PUMP W/ APPROVED HAIR & LINT STRAINER D. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE E. 2609000 BTU GAS HEATER W/ INTERNAL BY-PASS F. CHLORINE GENERATOR G. INSTALL PERMA-CAST PB-2011 WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ 98 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGR'S SPECS (FIELD VERIFY LOCATION) H. VALVES (TYPICAL) GENERAL NOTES: 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE, 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL BE BENT, MIN. 40 DIA. LAP SPLICE AND PLACED IN ACCORDANCE WITH ACI STANDARDS. PROVIDE 3" MIN. CONCRETE COVER OVER REINFORCING STEEL.. 4. GRATE 1N MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. S. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 2006 AND ANSI/APSP.ICC-15 2011. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED 1N COMPLIANCE WITH THE FBC SIXTH EDITION (2017) - RESIDENTIAL -PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. 11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SIXTH EDITION (2017) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. PRESUMPTIVE LOAD - BEARING VALUE OF SOIL - IN ACCORDANCE WITH FBC SIXTH EDITION (2017) SECTION 1806.2 THE SOIL BEARING VALUE SHALL BE A MINIMUM OF 2000 P.S.F. (FOLLOW GEOTECHNICAL ENGINEERING REPORT RECOMMENDATIONS OR INDUSTRY ACCEPTED STANDARDS - BY OTHERS) 13. SHOULD ANY MUCK, MARL, OR OTHER ORGANIC SOILS BE DISCOVERED ON EXCAVATION, THEY SHOULD BE REMOVED IN THEIR ENTIRETY, ALL CONSTRUCTION SHALL STOP AND THE ENGINEER OF RECORD SHALL BE CONTACTED TO CONDUCT AN INSPECTION. 14. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 15. POOL PLANS ARE DESIGNED TO MEET THE FBC FIFTH EDITION (2014) - RESIDENTIAL - PRIVATE SWIMMING POOLS. 16. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2006 AND FBC SIXTH EDITION (2017) - RESIDENTIAL CHAPTER 45. PLUMBING NOTES: 1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC SIXTH EDITION (2017), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS. 2. POOL PIPING SHALL RE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES. 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL CHECK PATTERN. 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS OR ANTI -SIPHON DEVICE. INSTALLED TO PROVIDE A POSITIVEMEANSOF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 6. ALL POOL PIPING SHALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. - 7. THIS POOLISPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO 3'-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOLISPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 8. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL„ 9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACKFLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 10. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15 MINUTES. It. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA BUILDING CODE, PLUMBING. 12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT TO THE HEATER. 43. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER FBC SIXTH EDITION (2017). 14. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS. (SEPARATE PLANS AND PERMIT REQUIRED) 15. SWIMMING POOLISPA WATER HEATERS SHALL BEAR THE LABEL OF A RECOGNIZED TESTING AGENCY. 16. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY. POOL/SPA SPECIFICATIONS SIZE: 26'-6" X 30'-0" DEPTH: 3'-0" TO 5'-0" VOLUME: 15,300 GALLONS ELEVATION: DET. ON SITE TURN OVER RATE: 7.1 HR. (a, 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 1.7 HR. * 150 GPM - HIGH SPEED) DESIGN FLOW RATE: = 15,300 GAL./6 HRS./60 MIN. = 43 G.P.M. TILE: STANDARD THERAPY JETS: (6) IN SPA POOL FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS: POOL (4) SPA (2) DECK: PAVERS ELECTRIC: BY OTHERS POOL LIGHT: 2 LED - NICHELESS SPA LIGHT: (1) LED - NICHELESS LADDER: NO HANDRAIL: NO REC. PUMP = 2.7 HP JANDY E-PUMP - JEP2.OVS A.P.S.P. PUMP CERT,: CURVE A - 35 GPM (a, 1730 RPM FILTER: JANDY CS200 CARTRIDGE 200 SQ. FT. FILTER AREA HEATER: JANDY 260,000 BTU GAS HEATER W/ APPROVED COVER VACUUM LINE: YES PODL AREA: 554 S.F. PERIMETER 125 L.F. SPA AREA: 42 S.F. PERIMETER 26 L.F. AUTO -FILL: YES . OVERFLOW: YES CHLORINE GENERATOR: YES - JANDY POOL CONTROLLER SYSTEM: JANDY RS-4 \ r� M •� O ti_'a QI �i v r'A 5 U a> w � � (ZI .` Zv •LL 0� co cl 2 co LO 2;w co K :24 2 0 ,i� • ; �J� �' • • �C %% U M10t- 4 in ~ 0' IF M aM W ti U W64o C) a�a 0 a r� V • W W W x U a a RENO I- W F-� C) ON 40 r n • wo s s �IIBj DRAWN BY: CLC CHECKED BY: WJC DATE: 5-11-19 SCALE: AS NOTED JOB NUMBER: 19-327 SHEET 2 OF 2